HomeMy WebLinkAboutSW6230803_Supplement-EZ Form_20230816 SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1 Project Name Dove Subdivision-North
2 !Project Area(ac) _ 35.818
3 Coastal Wetland Area(ac) 0
4 Surface Water Area(ac) 4.873
5 Is this project High or Low Density? Low
6 Does this project use an off-site SCM? No
COMPLIANCE WITH 02H.1003(4)
7 Width of vegetated setbacks provided(feet) I 30
8 Will the vegetated setback remain vegetated? _ _ Yes
9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A
10 Its streambank stabilization proposed on this project? No
NUMBER AND TYPE OF SCMs:
11 Infiltration System
12 Bioretention Cell
13 Wet Pond L_
14 Stormwater Wetland
15 Permeable Pavement
16 Sand Filter
17 Rainwater Harvesting(RWH)
18 Green Roof
19 Level Spreader-Filter Strip(LS-FS) _
20 Disconnected Impervious Surface(DIS) _
21 Treatment Swale
22 Dry Pond
23 StormFilter
24 Silva Cell
25 Bayfilter
26 Filterra
FORMS LOADED
DESIGNER CERTIFICATION
27 'Name and Title: Adam Freeman,Senior Design Engineer
28 Organization: McKim&Creed
29 Street address: 1730 Varsity Drive,Suite 500
30 City,State,Zip: Raleigh,NC 27606
31 Phone number(s): (919)233-6091
32 Email: afreeman@mckimcreed.com
Certificalian Statprnerd
I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that
the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans,
specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here.
Desraner
0\11II1/////,
\``\\\ CAR /0/
V;•,Ckl. n*gib 40.g 4 Cie
:Q
• SEAL gnature of Designer
—�' 044644 z_
F / I 0 Z3
tell t"/�11 � Date
DRAINAGE AREAS
1 Is this a high density project? No
2 If so,number of drainage areas/SCMs 0
3 Does this project have low density areas? Yes
4 If so,number of low density drainage areas 1
Is all/part of this project subject to previous rule
5 versions? No
FORMS LOADED
DRAINAGE AREA INFORMATION Entire Site LD 1
4 Type of SCM _
5 Total drainage area(sq ft) 1560236 1560236
6 Onsite drainage area(sq ft) 1560236 1560236
7 Offsite drainage area(sq ft)
8 Total BUA in project(sq ft) 133800 sf 133800 sf
New BUA on subdivided lots(subject to
9 permitting),.(sq ft) _ 93500 sf 93500 sf
New BUA not on subdivided lots(subject to
10 permitting)(sf) 40300 sf 40300 sf
11 Offsite BUA(sq ft)
12 'Breakdown of new BUA not on subdivided lots:
-Parking(sq ft) 700 sf 700 sf
-Sidewalk(sq ft) 300 sf 300 sf
-Roof(sq ft) sf sf
-Roadway(sq ft) 39300 sf 39300 sf
-Future(sq ft)
-Other,please specify in the comment box
below(sq ft) _
New infiltrating permeable pavement on
13 subdivided lots(sq ftL
New infiltrating permeable pavement not on
14 subdivided lots(sq ft)
Existing BUA that will remain(not subject to
15 permitting)(sq ft) _
16 Existing BUA that is already permitted(sq ft)
17 Existing BUA that will be removed(sq ft)
18 Percent BUA 9% 9%
19 Design storm(inches)
20 Design volume of SCM(cu ft)
21 (Calculation method for design volume
ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
22 drainage area(s):
LOW DENSITY
DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003
1 Is project below density thresholds set forth in the applicable stormwater rule? Yes
2 Does project maximize dispersed flow and minimize channelization of flow? Yes
3 Has the use of piping been minimized per.1003(2)(c)? Yes
4 Side slopes of the vegetated conveyances(H:V) 3 sf
5 Maximum velocity in the vegetated conveyances during the 10-year storm? 3.35
6 ;Are curb outlet swales proposed? I No
7 Maximum longitudinal slope of curb outlet swale(s)(%)
8 Bottom width of curb outlet swale(s)(feet)
9 Maximum side slope of curb outlet swale(s)(H:V)
10 Minimum length of curb outlet swale(s)(feet)
11 Are treatment swales used instead of curb outlet swales?
12 Is stormwater released at the edge of the setback as dispersed flow? Yes
13 Have stormwater outlets been designed to prevent downslope erosion? Yes
14 Are variations to rule.1003 proposed? No
ADDITIONAL INFORMATION
15 IPlease use this space to provide any additional information about this low density project:
Drainage Pervious
Swale BUA Q Slope Va.„ Flow depth
A(ac)rea area
(ac) (act C (cfs) (%) (fps) (fPs) (ft)
1 5.80 1.47 4.33 0.40 17.63 1.30 4.50 3.35 1.20
2 0.79 0.30 0.49 0.60 4.20 2.50 4.50 2.64 0.60
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
. 23
24
25
26
27
28
29
30
2