Loading...
HomeMy WebLinkAboutSW6230704_Supplement-EZ Form_20230810 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Riverfall Phase 2 2 Project Area(ac) 42.26 3 Coastal Wetland Area(ac) 4 Surface Water Area(ac) 5 Is this project High or Low Density? Low 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) 30 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? Yes NUMBER AND TYPE OF SCMs: 11 Infiltration System 0 12 Bioretention Cell 0 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 0 17 Rainwater Harvesting(RWH) 0 18 Green Roof 0 19 Level Spreader-Filter Strip(LS-FS) 0 20 Disconnected Impervious Surface(DIS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 Bayfilter 0 26 Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Jeffrey A.Nobles,PE 28 Organization: Larry King&Assoc.,RLS,PA 29 Street address: 1333 Morganton Road,Suite 201 30 City,State,Zip: Fayetteville,NC 28305 31 Phone number(s): 910-483-4300 32 Email: jnobles@lkanda.com cation Statement: certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer e.'`A>,.\CAR,- ,,, 60" 10 Q. `' i : l SEAL _ e S ,e•�D:.igne ,VC 31459 °',,,RE✓A. `s•` - -23 Seal Date DRAINAGE AREAS 1 Is this a high density project? No 2 If so,number of drainage areas/SCMs 3 Does this project have low density areas? Yes 4 If so,number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site LD 1 4 Type of SCM 5 Total drainage area(sq ft) 1840813 1840813 6 Onsite drainage area(sq ft) 1840813 1840813 7 Offsite drainage area(sq ft) 8 Total BUA in project(sq ft) 211065 sf 211065 sf New BUA on subdivided lots(subject to permitting) 9 (sq ft) 165000 sf 185000 sf New BUA not on subdivided lots(subject to 10 permitting)(sf) 11 Offsite BUA(sq ft) 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft) -Sidewalk(sq ft) -Roof(sq ft) -Roadway(sq ft) 46065 sf 46065 sf -Future(sq ft) -Other,please specify in the comment box below(sq ft) sf sf New infiltrating permeable pavement on 13 subdivided lots(sq ft) sf sf New infiltrating permeable pavement not on 14 subdivided lots(sq ft) sf sf Existing BUA that will remain(not subject to 15 permitting)(sq ft) sf sf 16 Existing BUA that is already permitted(sq ft) sf sf 17 Existing BUA that will be removed(sq ft) sf of 18 Percent BUA 11% 11% 19 Design storm(inches) .0 in .0 in 20 Design volume of SCM(cu ft) cf cf 21 Calculation method for design volume cf 0 ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): LOW DENSITY ME REQUIREMENTS FOR LOW iDENSRY PROJECTS FROM 02H:1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per.1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances(H:V) 3 sf 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 5 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s)(%) 8 Bottom width of curb outlet swale(s)(feet) 9 Maximum side slope of curb outlet swale(s)(H:V) 10 Minimum length of curb outlet swale(s)(feet) 11 Are treatment swales used instead of curb outlet swales? No 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes ____ 14 Are variations to rule.1003 proposed? I No ADDITIONAL INFORMATION _. 15 'Please use this space to provide any additional information about this low density project: Drainage Pervious Swale Area BUA area C CI Slope V„a„, V., Flow depth # (ae) (ac) ( ) (cfs) (%) (fps) (fps) (ft) 1 500.00 300.00 200.00 0.66 12.00 5.86 6.00 3.21 0.44 2 22303.00 14034.00 8269.00 0.68 5.40 1.16 6.00 2.64 0.72 3 31834.00 12802.00 19032.00 0.54 3.00 2.00 6.00 2.41 0.24 4 29142.00 15932.00 13210.00 0.63 5.10 1.00 6.00 2.85 0.33 5 15182.00 12969.00 2213.00 0.81 2.20 2.00 6.00 2.18 0.20 6 51425.00 24721.00 26704.00 0.59 6.00 2.00 6.00 3.32 0.67 7 8 3307.00 2627.00 680.00 0.78 12.50 3.07 6.00 4.68 0.82 9 3778.00 2611.00 1167.00 0.71 12.20 2,00 6.00 3.96 0.88 10 6280.00 3604.00 2676.00 0.64 7.00 1.00 6.00 2.66 0.81 11 4886.00 3083.00 1803.00 0.68 6.50 2.00 6.00 3.39 0.69 12 6691.00 3765.00 2926.00 0.64 0.70 2.00 6.00 1.46 0.10 13 500.00 500.00 0.00 0.90 7.90 3.25 6.00 3.21 0.51 14 5138.00 3232.00 1906.00 0.68 3.20 2.68 6.00 3.17 0.50 15 1425.00 757.00 668.00 0.62 2.40 3.77 6.00 3.35 0.42 16 1723.00 967.00 756.00 0.64 2.20 4.34 6.00 3.45 0.40 17 2856.00 345.00 2511.00 0.37 0.20 0.60 6.00 0.90 0.24 18 6107.00 2085.00 4022.00 0.50 2.10 4.46 6.00 3.45 0.39 19 10589.00 3585.00 6731.00 0.52 1.40 3.77 6.00 2.93 0.35 20 5381.00 1699.00 4132.00 0.47 0.50 2.00 6.00 1.78 0.27 21 44655.00 12995.00 12034.00 0.61 2.70 2.00 6.00 2.72 0.50 22 7901.00 7777.00 124.00 0.89 4.80 2.50 6.00 3.11 0.65 23 9334.00 5142.00 4192.00 0.63 3.90 3.77 6.00 3.78 0.05 24 1439.00 793.00 646.00 0.63 3.00 2.00 6.00 2.78 0.52 25 4884.00 0.00 4884.00 0.90 0.30 2.00 6.00 1.57 0.22 26 11.p(i 27 691.00 252.00 439.00 0.52 0.10 0.60 6.00 0.08 0.18 28 29 30