Loading...
HomeMy WebLinkAboutDogwood Plans 2023-08-04 DewateringGENERAL NOTES: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL ABOVE GROUND AND UNDERGROUND FEATURES SHOWN ON DRAWINGS (PLANS). ADDITIONALLY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR EXERCISING REASONABLE EFFORTS TO PROTECT ANY UNKNOWN UNDERGROUND FEATURES. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY IF UNKNOWN FEATURES ARE DISCOVERED THAT WOULD NECESSITATE MODIFICATION TO THE ILLUSTRATED DESIGN. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONFIGURATION OF ALL EXCAVATION, UNDERCUT, AND BACKFILL AREAS AND FOR MAINTAINING A SAFE WORK ENVIRONMENT IN ALL AREAS OF THE CONSTRUCTION SITE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATORY REQUIREMENTS. 3. CONSTRUCTION AND/OR DEMOLITION ACTIVITY, INCLUDING LOADING AND UNLOADING OF MATERIAL, IS PROHIBITED BEFORE 7 AM AND AFTER 7 PM MONDAY THROUGH FRIDAY. WORK IS NOT PERMITTED ON WEEKENDS OR HOLIDAYS WITHOUT PRIOR WRITTEN APPROVAL FROM THE ENGINEER. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING THE EXISTING STRUCTURES, ALL ADJACENT PROPERTIES, THE GENERAL PUBLIC, AND ALL OF THE OWNER'S FACILITIES. SHOULD DAMAGES OCCUR, THE CONTRACTOR SHALL REPAIR, AT HIS EXPENSE, IMMEDIATELY TO THE SATISFACTION OF THE OWNER AND THE ENGINEER. 5. CONTRACTOR SHALL HOLD HARMLESS THE OWNER AND THE ENGINEER FOR DAMAGES, INJURIES, OR OTHER ACCIDENTS WHICH OCCUR DURING THESE CONSTRUCTION ACTIVITIES. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR THE SECURITY OF THE CONSTRUCTION SITE, INCLUDING BUT NOT LIMITED TO: HIS EQUIPMENT, COMPLETED WORK, STAGED MATERIALS, AND SITE ACCESS BY AUTHORIZED AND UNAUTHORIZED PERSONS. 7. TREES AND EXISTING LANDSCAPING NOT DESIGNATED FOR REMOVAL SHALL BE PROTECTED DURING CONSTRUCTION. 8. CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATION OF ALL ILLUSTRATED CONSTRUCTION ACTIVITIES AT THE JOB SITE. 9. CONTRACTOR SHALL ENSURE THAT ALL WORK IS PERFORMED ACCORDING TO CURRENT OSHA SAFETY REGULATIONS. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES DURING CONSTRUCTION AND SHALL MAKE REPAIRS AT HIS EXPENSE. 11. CONTRACTOR SHALL UTILIZE SIGNS, BARRICADES, FLAGMEN, OR GUARDS AS REQUIRED TO ENSURE THE SAFETY OF ALL VEHICULAR AND PEDESTRIAN TRAFFIC DURING THE CONSTRUCTION PERIOD. 12. CONTRACTOR SHALL COORDINATE WITH THE ENGINEER, THE OWNER, AND ADJACENT PROPERTY OWNERS AS REQUIRED FOR WORK OUTSIDE OF HOA PROPERTY OR EASEMENT. 13. CONTRACTOR SHALL NOT LEAVE ANY EXCAVATION OPEN OR UNPROTECTED DURING NON -WORKING HOURS. CONTRACTOR SHALL UTILIZE SIGNS, FENCES, BARRICADES, ETC, TO ENSURE THE SAFETY OF BOTH AUTHORIZED AND UNAUTHORIZED PERSONS WHO ENTER THE SITE. 14. CONTRACTOR SHALL BE RESPONSIBLE FOR LAYOUT OF ALL WORK AS ILLUSTRATED ON PLANS. IF EXISTING CONDITIONS DIFFER FROM THOSE ILLUSTRATED ON PLANS, CONTRACTOR SHALL NOTIFY ENGINEER PRIOR TO CONSTRUCTION. 15. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND GRADES AT THE JOB SITE. IF DIFFERENCES ARE FOUND, HE SHALL NOTIFY ENGINEER IMMEDIATELY SO THAT MODIFICATIONS TO THESE DRAWINGS CAN BE MADE. 16. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING THE PROPER UTILITY COMPANIES AND FIELD LOCATING ALL UTILITIES PRIOR TO CONSTRUCTION. ALL EXISTING UTILITIES AT THE PROJECT SITE SHALL REMAIN, UNLESS OTHERWISE NOTED IN THE CONTRACT DOCUMENTS. ANY TEMPORARY INTERRUPTIONS AND/OR DIVERSIONS IN UTILITIES SHALL BE APPROVED BY THE ENGINEER AND PERFORMED IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE, AND LOCAL REQUIREMENTS. 17. CONTRACTOR SHALL PREPARE A DETAILED CONSTRUCTION SEQUENCE FOR REVIEW BY THE ENGINEER PRIOR TO CONSTRUCTION. CONTRACTOR SHALL PROVIDE THE DETAILED CONSTRUCTION SEQUENCE TO THE ENGINEER AT LEAST 2 WEEKS PRIOR TO BEGINNING OF CONSTRUCTION. 18. CONTRACTOR SHALL PREPARE A DETAILED CONTROL OF WATER PLAN FOR REVIEW BY THE ENGINEER PRIOR TO CONSTRUCTION. 19. FINISHED ELEVATIONS OF ALL HARD SURFACES (CONCRETE) SHALL BE ACCURATE TO = +/- 0.08'. 20. CONTRACTOR SHALL PROTECT EXISTING SANITARY SEWER MAIN WITHIN THE PROJECT LIMITS. DEPTH OF SEWER MAIN AT EMERGENCY SPILLWAY CHANNEL SHALL BE FIELD VERIFIED TO CONFIRM NO CONFLICT. NOTIFY THE ENGINEER OF ANY CONFLICT. SEE SHEET 4 FOR MANHOLE AND SEWER MAIN LOCATIONS. VILLAGE OF WESLEY CHAPEL DOGWOOD PARK UNION COUNTY, NC 84 / Weddin N wn Rd VICINITY MAP N TS SITE DATA MAILING ADDRESS: 6490 Weddington Road Wesley Chapel, NC 28104 Physical Address: 121 Lester Davis Rd (S.R. 1339) Waxhaw, NC 28173 COUNTY: WAKE State Dam ID: Union-128 Contact Info: (704) 839-0182 clerk@wesleychapel*inc.com Wetland Impact: 984 SF 0.02 AC Sheet List Table Sheet Number Sheet Title 1 Cover 2 Existing Conditions 3 Demolition Plan 4 Site & Grading Plan 5 Erosion Control & Sedimentation Plan 6 Primary Outfall Plan & Profile 7 Riser Detail 8 Outlet Details 9 Erosion Control Details 10 NCG01 Details Know what's below CALL before you dig. _ Q �4 Q) L w N CNC IT 7DZi �L � � M Mama a F . $r01 �� SEAL �7 — 024457 z 0 a 0 m ¢ 0 0 z w 0 � o L) Q0 0 0 m m Q � � z m � ¢ � o o N � a 0 a ¢ C� V A w w o � GENERAL NOTES: 1. BEARINGS BASED ON NORTH CAROLINA GRID SYSTEM (NAD '83) AND TIED TO NGS MONUMENT "UNION HM61" 2. PROPERTY SURVEYED WITHOUT THE BENEFIT OF .A TITLE SEARCH. 3.CONTOURS ARE BASED ON NAVD '88 DATUM AND CONTOURS ARE AT ONE FOOT INTERVALS. 4+ THIS IS NOT A BOUNDARY SURVEY. PROPERTIES DEPICTED ARE .SHOWN FROM. COMPILED DATA TAKEN FROM UNION COUNTY. GIS AND THE UNION COUNTY REGISTER .OF DEEDS. ALL OWNER INFORMATION IS NEW OR FORMERLY. I, KENNETH M..GREEN CERTIFY. THAT THIS MAP WAS DRAWN UNDER MY SUPERVISION FROM AN ACTUAL SURVEY MADE UNDER MY SUPERVISION; THAT THE VERTICAL ERROR DOES NOT EXCEED MORE THAN ONE --HALF THE INTERVAL OF THE PLATTED CONTOURS OVER 90% OF THE COVPC0"ARFj4,� CA O R,.'', /�,p'. ��`O�"��•CAissR�(f SEAL __ - ' �� vy9r•.A L• 351 Z - ' x� ' m SEAL ASS KENNETH M. GREEN, PL.S L-3512 i111111111110"%• i, Robert F. Akers, Jr., a Professional Land Surveyor in North Carolina, certify that this project was completed under my supervision from an actual photogrammetric survey made under my supervision. that this photogrammetric survey was performed to meet Federal Geographic Data Committee (FGDC) Standards for a final reap scale of 1" = 100' and a contour interval of one foot using imagery with ❑ Ground Sample Resolution of 0.40% that the imagery was obtained on January 8, 2011 and the phatogrammetric survey was completed on, February 15, 2011; that contours shown as broken lines may not meet. F'GDC Standards due to obscurred ground and that all coordinates and elevations . shown are based on North Carolina Grid Coordinates, as.supplied by R. Joe Harris. . R. Joe Harris field located the features shown on this project and Avioimage incorporated the field data which was dated June 15, 2022. Robert F. Akers, Jr. PLS L-2965 GAi,�o o P ti G > �. ,No.2965 f_ N, �� AVIOIMAGE MAPPING ' SERVICES,INC. C'7 No. F-0810 -r. Q WEDDINGTON RI) (NC HWY 84) ,,.I.II...,-- . AM110il(VAM►Ia —1QQ 0 50 100 200 ( IN FEED } 1 inch = 100 ft. 0 IS TO BOTTOM OF POND . TH OF MUCK IS NOT INCLUDED IN THE TOPO IDLE CURRENT OWNER: VILLAGE OF WESLEY CHAPEL 6490 WEDDINGTON ROAD, WESLEY CHAPEL, NC 281.04 VICINITY MAP NOT TO SCALE REMOVE -XIS 12 "—CP AND_ — / / // —� w vvvv vv I \ \ REPLAC ITM IqEW IB"� R�P — v v v v v 600 _--- A EX. M H RIM: 599.30 - CLEAR/AND GRADE 596 INV IN: 581.25 \ \ \ \ I y / �- /� �5g7-_ _ -�-_ �� V INV OUT:581.11 _ - - ---_ � TO N�/TREELINE FOR _ __-- — _ _ - _ EXISTING 12in HDPE v TRAIL RELOCATION01 599— —598— —597 1*W TREE E �5ss' — i — O —594 -593— / $ -592 \/ Z. vp EXISTING �S�EFz 6� P - - -i-� / / / // / / =F GO��.. \ ' In CpP \ WAY / )p� OVERHEAD ELECTRIC GREEN— �/ f�-593 PR�S�� \NGSP`� ! -� /Sp/WAYS \� 592--- / —592__ :,' :. �S� — — X —i XIS �9R EXISTING�— p1 , 588 \ TREE AREA _ _ \ —591— _ \ — // / // U, �L��� /% / EX\S \ \ _590 OBE \ — ---- __ — --- CLEARED— -- -590— LIMITSOF/�� 589 --_ ---- ---� ___- -�I STURBAV C / /.5�586—- / .s5-----589----- ---- G s L -TREEL-NE EXSTI—5 `-- --588--EXISTING ■-- -...---...---...�- _ _- _ LOD �( I I I I I I I I — _WATER LEVEL— /-587— — �\ _ / i // I I _-- -------------- %- j.. %, L saa, I II I II 583— i — _ — 586 — ' \ — — — — — ——`...�5 \ o I I I I €MOV-E--AND DISPOSE OF I \or s---- — — ---_ EXISTING PEDESTRIAN BRIDGE mug 001 \ I� II II I 009 EXISTING O I R�E�M\OVEAND DISPOSEEXISTING 1I �'SS TREE AREA TREE AREA o LoI rn wmII mIaI0585 S�<� � Ln SEXISTING RISERTRASHs" -584 - ----------- EX. MH RACK AND 24�� CMPsa3-RIM:58589 _5g4 I � ' \ TOPO IS TO BOTTOM OF POND DEPTH. 580-- - -s8j - _ , _ INV IN: 575.64 DEPTH OF MUCK IS NOT INCLUDED IN THE TOPO AVG. -5 _ 83- EX. MH — — �2 II I I II I II I I II - - � - sso_ - — -579_ - INV OUT: 575.34 I WATER SURFACE ELEV = 586.14 _ _ \ _ \ RIM: 584.37 ^ — _ _ —NEW \ \ I \ \ INV IN: .47 — — \ / TREELFNE 5a2— ,582 \ I I II I I I I I III I I \ \ IN\TOUT: 573.13 I — sss NG TREELI / _ \ /� Tf x 5a EXISTING ..5—so I I I I I I II EXISTING \ - WATER OF WETLAND O BE REMOVED ING i4CiP TSPOUT \\ _ — -LIMITS / EINV. OUT-578.58IMPACT DISTUR13AUCCE X/S �_v-G 57778- IJ EXIST (�G RI�ERi-s7s�I I I I I I I I TOP-587.82i Q I I I I I — --_ �". / . • — — �— —... -- ----— — -- ...— -- .78 ... _ __ 0a0TemI n OI tUI � � 'M� -57—�, i) 00 a0 0 �TEMPORARILY- -REPLACE �� REV0fEAN D___-- - - i - - - --- — I I L ao, m00, �EXISTING�BENCHES— -- ---- -- WATER EXISTING EVELEXISTINGA'NCE- EXISTING CREEK tiDEL MKS WETLAND -- - -- � ---- . ILIMITS F, — — — // ��� I I I r I �I 84\ sss UW ANq` _ DIST — �-586— �\\. L,II�E, / / ��� i �5a7_ _ — j`� / � \� __ 589 / / `� 5 9 0 —591—_-- I v DEMOLITION NOTES 1. ALL WORK SHALL BE PERFORMED WITHIN HOA PROPERTY OR TEMPORARY CONSTRUCTION EASEMENT WITHIN THE PROJECT AREA AS SHOWN ON THE PLANS. 2. TREES WITHIN THE CONSTRUCTION LIMITS OR LIMITS OF DISTURBANCE THAT DO NOT CONFLICT WITH CONSTRUCTION SHALL REMAIN AND BE PROTECTED FROM DAMAGE, UNLESS OTHERWISE DIRECTED BY THE ENGINEER. 3. DEMOLITION SHALL INCLUDE THE COLLECTION AND REMOVAL OF ALL TREES, STUMPS, BRUSH, VEGETATION, TRASH, DEBRIS, WASTE CONCRETE, WASTE ASPHALT, WASTE PIPING, AND ANY OTHER UNSUITABLE MATERIAL WITHIN THE LIMITS OF CLEARING AND GRUBBING, UNLESS INDICATED OTHERWISE ON THE PLANS OR DIRECTED BY THE ENGINEER. 4. DEMOLITION SHALL INCLUDE THE REMOVAL OF ALL DEBRIS AT ALL TEMPORARY DRAINAGE DEVICES. THE REMOVAL OF DEBRIS SHALL BE MAINTAINED TO ALLOW CONSTANT DRAINING OF THE POND DURING CONSTRUCTION. 5. EXISTING TOPSOIL SHALL BE STOCKPILED FOR LATER USE BY THE CONTRACTOR. 6. ANY STOCKPILES, ETC., SHALL BE REMOVED BY THE CONTRACTOR PRIOR TO CONSTRUCTION COMPLETION, UNLESS DIRECTED OTHERWISE BY THE ENGINEER. TREE REMOVAL NOTES 1. CUT THE TREE APPROXIMATELY TWO FEET ABOVE GROUND LEAVING A WELL-DEFINED STUMP THAT CAN BE USED IN THE ROOTBALL REMOVAL PROCESS 2. REMOVE THE STUMP AND ROOTBALL BY PULLING THE STUMP, OR BY USING A TRACK -MOUNTED BACKHOE TO FIRST LOOSEN THE ROOTBALL BY PULLING ON THE STUMP AND THEN EXTRACTING THE STUMP AND ROOTBALL ALL TOGETHER. 3. REMOVE THE REMAINING ROOT SYSTEM AND LOOSE SOIL FROM THE ROOTBALL CAVITY BY EXCAVATING THE SIDES OF THE CAVITY TO SLOPES NO STEEPER THAN 1:1 AND THE BOTTOM OF THE CAVITY APPROXIMATELY HORIZONTAL. 4. BACKFILL THE EXCAVATION WITH WELL -COMPACTED SOIL PLACED IN LIFTS NOT GREATER THAN EIGHT INCHES IN LOOSE LIFT THICKNESS. SEE TECHNICAL SPECIFICATIONS SECTION 02300: FILLING & STABILIZING. — / 593— � � \ ' — — ----------- ,597 EXITING -599- ARE — — � —598— — �i _5g9 � / / / i — — � � I I - --�- /I-599— _ _ ,� GRAPHIC SCALE 20 0 10 20 40 80 (IN FEET) finch = 20 ft Know what's below CALL before you dig. � Q CQ �/ QJ m C� (� cUrn F0 z . y ■ 2i Qj T U-m 50 m M �' E Y a ..ti SEAL 024457 �iy��,,Y►+�►i�inigLA,��,b � z 0 a L) w 0 m W d Q 0 z w o n w O O > m Ln LO z Q Q N o a CI O 0 "mo O O O A W w M C` o � Tuesday, June 20, 2023 9:06:35 AM LOD �Cqp \ \ \ \ \ / �/� / kp— 598- — — — \ NEW TREELINE / r _ S 8 Y _596- 594— — — — — — L — _ -- 1 5g0 `� — — / . Al •• . . \ \ 593 59 —591 --- L �cq,/ \ // /--- Z \------ / / / / �� .. : SS \ N INV IN: — , — NEW GRAVEL TRAIL / / / / / sf' \ G 5a9 % - - \ / 590.5 15P/ / S / EXISTIN AY / \%p Ism // � L co_----_-- / / EXISTING SANITARY SEWER. s APPROX. 10' OF COVER. I 5a� / 3 Bob �sqo I NEW 4 E� 18 RCP FIELD VERIF Y DEPTH. I / / —� ' \sue I ERT@2?�7% \ --- — — — — — — - - CLASS "2" STONE RIPRAP w/S__ I T NCDOT R N — TYPE 2 FILTER FABRIC OU o \ \ -ss — /588. 2,--- r EXISTING PICNIC -- ARE � — -591— 40 BRIDGE SPAN, 588 591 _ — / / / SEE SPILLWAY DETAIL SHEET \ `99� j/�� V �� 5gs v \ �s90 NEW — \\ L� 5j �� // \ \ TREE / / \\ rn� \ 5 EXISTING PICNIC — - --- — / : 5a� �/ / / �� ,SSA 25.0' — —587 — AREA — - - — — — — --- iao �'A° SPILLWAY - 58s\ — ---- ---- — — --- / s86--------- -- ---- _ =sss=--- —__... ---- 8 I - -�--I� sssSS �------- 000 tip 40 584- — — \01 I �LOU L� — — _ SS--- 8^ ----- L — 'S83 / SS -7 --586 i / LIMITS OF �' / \ \ 3• ? APPROXIMATE LO TION OF 689 I I I I I — — ` \ / DISTURBANCE PIEZOMETERS TO BE F LOCATED \ \ I I I 5g2^ BY GEOTECHNICAL NGINEERS.003 \ I I I I LO I �585 REINFORCED \ ` CONCRETE ENDWALL �I�sas II I I I I II I II I I \ \ SEE DETAILI \ Qco LD In a 584— _ — Lo I I / _-- — —co-- \ S851. I I I I I I I I I M s �� s� co I I s� R I I I I I I I / I SAND FILTER _ - I I PROPOSED 8.0' x 16.0' CONCRETE RISER — -00 I I I DIAPHRAGM I I I w/ TRASH RACKCREST ELEV: s83— 586.00. , — — — NEW :b� -- — — \ I I I I I SEE DETAIL I I I SEE RISER DETAIL \ TREELINE �' '-----------�\ �\ \oo / 583__ --� / \ I I 3:1 I I I I I I I \\ 00 / — --- lb CLASS 2 STONE I I I I r \ J — — — 581 \ M \ I I I I I / 8 EXISTING \ I / / — 552— — 8 RIPRAP w/ NCDOT — o \ I I I I I I I I \ TYPE 2 FILTERs v I I I I / WATER v v — — FABRIC SPOUT \ / — / I I --- - -- -- � _ \ 1 I 580 581— / I I I LIMITS OF — LO —° I ::-_:..::: .:< •. 1.. 1 1 V' — s8 $- 7- 7g�� \ I I I I 64 LF 60 In RCP 1 580 1 DISTURBANCE — M— 57 $� \ \ i I I -\\\\� — 57 I •M1. 4 57580— c CLASS "2" STONE RIPRAP w/ I NCDOT TYPE 2 FILTER FABRIC I I I I I I I 6 r _ -579- co II I I II I I I I I 64 LF 60 in RCP i GATE i 8 I I BOO •-579 5�g -� ' LOD - ' / i VALVE I 579 / _�--' 1 1 I SEE S"LOW FLOW AREA" DETAIL 78 I N I - - J�� \ 1 o of oo r I n ao m Lo CIS^ ------------'579---_•--- -----J ._. - / III II III 1 I II� / CLASS "2"STONE RIPRAP w/ l I I I I I I III I —�78 3: NCDOT TYPE 2 FILTER FABRIC I I I II CI'^ -0 � I I CONCRETE �1 � 00' I I( I I II II I II I1 I II I I II I IIII CON RETEI ICRADLE TO I I I INTEGRA SLAB 8 aoi ao� aoi_°°1 �7 SPRING NG LINE, SEE DETAIL.` SEE RISER DETAIL "/ -- W I I I I I I I II I / EXISTING ` / � ' I I I CREEK BANKS c5� / / iO / I I I / oo I I I STONE BEDDING TO SPRING LINE. � I / MIN. 12 EITHER SIDE OF PIPE lb> / mow"' / V I I #57 STONE, 12" MIN. DEPTH LO I I I I I I I \\ \\ `0 I I I I I I \ S _ eo _ // / I� I I 4. \ / I � 4�- I I � II I II II I III � � 585� � GRAPHIC SCALE 8a I I m\ I II \ 10 0 5 10 20 40X NEW mc7' / / / TREEL�NE / / �� z \ \ \ -- i-.� / / /`' D� I� \ \-- -- -- -- (IN FEET) / / / `� / ` v 1 inch = 10 ft Know what's below CALL before u d I lift Q CQ �/ Q) m ) N c C� (� z i- W .5 m L M M C Ua Y ..ti SERL 024457 g . n� •�����hl►t111111111U��� I0, z 0 a w 0 m w F- 0 0 z w ai n N o w 0 0 m < o ZII Q ¢ Q o � N o a a Q� o M 1LI 0 0 V1 W w 0 o � Tuesday, June 20, 2023 9:06:44 AM i LOD --- 599 SSg --/ -- g S 597 �596j �- i �o/ \ --- \ i- 5944 - � 591 / - _ _ 593 �S �59 V L� \ s �_—.— __ r� _ o/ o — � EXISTING �p �� �� --' / �/5 —_ — / o� \ ssz_- -- EXISTING RI OVERHEAD ELECTRIC '� �\S \G \ -- ssz � � — — , � - - � / �/ � r? / _ PI IG� I — se8 � - ' 5g'I � � � 5\ AREA a 5/ � s`55901 ss1 6G ----` ---//� ' _ �- / 0 i 8\ � -591-- -- - - — — � — — � / ' 5a 58g� EXISTING 590_- - PICNIC -- / ( — — _ ,58i 5- _ -587- AREA i _ 5) � A 589 - / g - -- - 587 / I � 590� - - LAOi i oIo � _ - ¢ /-VW 686— --- ------ // / - - -- _ - -- --586- - -- - - 8 589 - --- 4") 01 0, �p .100 1`�/ — 585 ----- — — — .565 — — — —584 _ 588 - 5$� LOD --sal -- --- LO-- - UR6ANCE OF pIST LIMITS - o� ' 58 3--- --- -- - - - - ----- --- --- --- --- - - - - --586- / o a0Y / / nw �• - - S8 I I LOD _ _ �� / aa� / 58s, 1 �� �I I �� ,582 ao1 ao-► 1 om � °°' � oo-, � sas s8 II rnl I�' I � I III I I LIMITS OF - - - �,001 - - - �� o �, I DISTURBANCE: — — / 585- ��� oAo �SBS 00 n 'n 'o m m m I u°Di 40 ----- --- -- - a4 i S SS _ _ --- — SS = _ — SS - --- — s 8s I 38,654 SF, 0.89 AC. — -- =_S�— --sa __— / -- � ---- — �� say -- ---- 4 - _ 5a4 M� Q I _58�--- c ti__ -- - - -- - `rcPu �1 I II II \ I II 580- \ 583 - - --- -- -- c5 I s - - 87 _ _- 583- - cPr, u� - \ - _ -- -= 57901) 0 --_ - 58 �� d' Lo - - -- / / / _ 582 I --ham- 582 - 581� 00 _ - J — — \ - ----- S�8 9_ I I I 8 EXISTIN G =5a� 4j�$ 64LF60In 580 � Y/TE\ SPOUT ROCK 5580- SEE PLAN &PROFILE SHEET #6 -- --- _ CHECK \ — I DAM g_ 7g��r, �.�_ate ►�`.� .�'' 5 57579- 64 LF 60 EXISTING FOOT 579�b7� I BRIDGE o rn 10 o ro 00 OD— — — / -- Lp ��O ono w� Lr) °n° — — — I - — V - _ 3- - - .s n ' i 1' I. LIMITS OF DISTURBANCE �5ao "� � L' 4 - am I I � �EXISTING CREEK ° BANKS n I I I II I 00LOI­ I - — — hI I I I II - 01) \ I—, --' - - / / g0'1 in�l III 585 � � _ / � j i � � � � �- \----585= h 589 593 TEMPORARY SEEDING TEMPORARY SEEDING SHALL BE COMPLETED WITHIN 24 HOURS OF COMPLETION OF GRADING ACTIVITIES IN ANY WORK AREA. TEMPORARY SEEDING SHALL NOT BE REQUIRED IN AREAS IMMEDIATELY SEEDED WITH PERMANENT SEED. SEED: APPLY THE FOLLOWING VEGETATION AT THE LISTED RATES. • FALL, WINTER, AND SPRING SEEDING (AUGUST 15-MAY 1): RYE GRAIN 120 LB PER ACRE •SUMMER SEEDING (MAY 1-AUGUST 15): BROWNTOP MILLET 40 LBS PER ACRE MULCH: APPLY 4,000 LBS./ACRE GRAIN STRAW. PROVIDE BIODEGRADABLE MATTING IN LIEU OF MULCH ON SLOPES 3:1 OR STEEPER. PERMANENT SEEDING APPROVED DATES FOR PERMANENT SEEDING ARE SEPTEMBER 1 TO OCTOBER 31 AND FEBRUARY 15 TO APRIL 30. OUTSIDE OF THESE TIME FRAMES, PERMANENT SEEDING CAN ONLY BE DONE WHEN COMBINED WITH TEMPORARY SEED UNDER COIR MATTING OR WITH PRIOR APPROVAL BY THE ENGINEER. AREAS TO BE SEEDED SHALL BE RIPPED AND SPREAD WITH TOP SOIL 3" DEEP. TOTAL SEEDBED PREPARATION DEPTH SHALL BE 4" TO 6" DEEP. PERMANENT SEEDING (,SPRINGI SPRING (FEBRUARY 15 - APRIL 30): TALL FESCUE 200 LB PER ACRE NOTE: RE -SEEDING IN THE FALL WILL BE NECESSARY IF PERMANENT VEGETATIVE COVER IS NOT ADEQUATELY ESTABLISHED. PERMANENT SEEDING (FALL) FALL (SEPTEMBER 1 - OCTOBER 31): TALL FESCUE 200 LB PER ACRE NOTE: COIR MATTING AND MELLOW MARSH RIPARIAN BUFFER MIX, OR APPROVED ALTERNATIVE, REQUIRED ON STREAMBANKS. MULCH: APPLY 4,000 LBS./ACRE GRAIN STRAW OR EQUIVALENT COVER. PROVIDE BIODEGRADABLE MATTING IN LIEU OF MULCH ON SLOPES 3:1 OR STEEPER. SEE SPECIFICATIONS FOR SEEDING METHODS AND WARRANTY. STABILIZATION TIMEFRAMES SITE AREA DESCRIPTION PERIMETER DIKES, SWALES, DITCHES, SLOPES HIGH QUALITY WATER (HQW) ZONES SLOPES GREATER THAN 3:1 SLOPES 3:1 OR FLATTER ALL OTHER AREAS WITH SLOPES FLATTER THAN 4:1 STABILIZATION TIMEFRAME EXCEPTIONS 7 DAYS NONE 7 DAYS NONE 7 DAYS IF SLOPES ARE 10ft OR LESS IN LENGTH AND ARE NOT STEEPER THAN 2:1, 14 DAYS ARE ALLOWED. 14 DAYS 7 DAYS FOR SLOPES GREATER THAN 50'IN LENGTH 14 DAYS NONE, EXCEPT FOR PERMIETERS AND HQW ZONES. EROSION CONTROL NOTES: 1. THE CONTRACTOR SHALL INSTALL ALL EROSION AND SEDIMENT CONTROL MEASURES AND DEVICES ACCORDING TO THE STANDARDS AND SPECIFICATIONS OF THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY AND APPLICABLE STATE AND LOCAL LAWS AND ORDINANCES, AND PREVENT STANDING WATER WITHIN PROJECT LIMITS. 2. CONTRACTOR SHALL TAKE APPROPRIATE MEASURES TO PREVENT SEDIMENT FROM LEAVING SITE. STREETS AND PAVED PARKING AREAS SHALL BE SWEPT REGULARLY TO KEEP THE TRACKED SEDIMENT FROM ENTERING THE STORM DRAINS AND STREAM. 3. CONTRACTOR SHALL INSTALL TEMPORARY EROSION CONTROL DEVICES WITHIN THE PROJECT AREA AS REQUIRED TO CONTROL SEDIMENT TRANSPORT PRIOR TO COMMENCING EARTHWORK. IF ADDITIONAL STAGING/STOCKPILE AREA IS REQUIRED, THE AREA MUST BE APPROVED BY THE ENGINEER AND SILT FENCE MUST BE INSTALLED BEFORE USE. 4. CONTRACTOR SHALL ENSURE THAT DRAINAGE IS DIRECTED INTO TEMPORARY SEDIMENT DEVICES THROUGHOUT THE CONSTRUCTION PERIOD. 5. AS EACH PORTION OF CONSTRUCTION IS COMPLETE, CONTRACTOR SHALL INSTALL PERMANENT STABILIZATION. AT END OF PROJECT, WHEN AUTHORIZED BY THE ENGINEER, CONTRACTOR SHALL REMOVE ALL TEMPORARY EROSION CONTROL MEASURES, INSTALL PERMANENT STABILIZATION, AND RESTORE THE SITE AS SHOWN ON PLANS, OR AS CLOSELY AS POSSIBLE TO ORIGINAL CONDITIONS. 6. CONTRACTOR SHALL PROVIDE SOIL STABILIZATION FOR ALL DISTURBED AREAS BASED ON TIME FRAMES SHOWN ON STABILIZATION TIMEFRAME CHART WITHIN THE SPECIFIED CALENDAR DAYS FROM THE LAST LAND -DISTURBING ACTIVITY. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCOMMODATION AND MAINTENANCE OF BASE AND STORM FLOWS IN ALL AREAS OF THE PROJECT SITE THROUGHOUT THE CONSTRUCTION PERIOD. SEE TYPICAL PUMP -AROUND DETAIL. 8. CONTRACTOR SHALL INSPECT SITE AFTER EACH RUNOFF PRODUCING RAINFALL AND REPAIR VISIBLE EROSION. CONTRACTOR SHALL REPAIR AND REPLACE EROSION CONTROL DEVICES AS NECESSARY. 9. DE -WATERING OF STRUCTURES WITH SEDIMENT -LADEN WATER DIRECTLY TO STREAMS OR STORM DRAINAGE SYSTEM IS PROHIBITED. THE CONTRACTOR SHALL TAKE APPROPRIATE ACTION TO ENSURE THAT SUCH PROHIBITED ACTIVITIES DO NOT OCCUR. 10. PERMANENT GROUND COVER IS REQUIRED ON ALL DISTURBED AREAS OF THE CONTRACT. MULCHING SHALL BE PROVIDED FOR ALL AREAS REQUIRING SEEDING. LAKE DRAW DOWN PLAN 1. LAKE SHALL BE PUMPED DOWN AT A RATE NOT TO EXCEED ONE FOOT WATER SURFACE ELEVATION PER DAY. SURFACE AREA OF LAKE = 1 1 1 ,174 SQUARE FEET MAXIMUM DRAW DOWN = 111,174 CUBIC FEET PER 24 HOURS. 81320 CUBIC FEET PER DAY = 1.287 CFS = 578 GPM 2. PUMPED DISCHARGE FROM THE LAKE MUST BE DISCHARGED THROUGH A FILTER BAG UNLESS THE FOLLOWING CONDITIONS CAN BE MET: 1 — INTAKE IS AT LEAST ONE FOOT ABOVE LAKE BOTTOM AT POINT OF INTAKE. 2 — PUMPED FLOW IS DISCHARGED TO A RIPRAP PAD FOR ENERGY DISSIPATION. SEE DETAILS ON SHEET 9.0 FOR TYPICAL PUMP AROUND AND DEWATERING WITH FILTER BAG DETAILS. 3. AS THE LAKE LOWERS, CONTRACTOR SHALL INSPECT DISCHARGE TO CONFIRM THAT SEDIMENT IS NOT BEING TRANSMITTED DOWNSTREAM. 4. FLOW BEING PUMPED FROM LESS THAN ONE FOOT ABOVE THE LAKE BOTTOM AT THE POINT OF INTAKE SHALL BE DISCHARGED THROUGH A FILTER BAG. 5. ONCE CONSTRUCTION BEGINS, THE LAKE SHALL REMAINED DRAINED AT ALL TIMES UNTIL APPROVAL TO IMPOUND IS AUTHORIZED BY THE STATE DAM SAFETY OFFICE, NCDEQ. SUGGESTED PROJECT SEQUENCE 1. INSTALL EROSION CONTROL MEASURES AS SHOWN ON PLANS. 2. INSTALL TEMPORARY FLOW DIVERSIONS FOR CONTROL OF WATER. 3. REMOVE EXISTING OUTLET STRUCTURES. 4. INSTALL PROPOSED STRUCTURES, BACKFILL, AND GRADE EMBANKMENT AS SHONW ON THE PLANS. 5. GRADE EMERGENCY SPILLWAY AS SHOWN ON THE PLANS. 6. INSTALL RIPRAP AT DISCHARE LOCATION AS SHOWN ON THE PLANS. 7. REMOVE TEMPORARY CHECK DAM. 8. STABILIZE REMAINING DISTURBED AREAS WITH SEED AND MULCH. 9. REMOVE THE CONSTRUCTION ENTRANCE AND STABILIZE THE AREA. 10. REMOVE REMAINING EROSION CONTROL MEASURES AFTER SUFFICIENT STABILIZATION HAS OCCURRED.. GRAPHIC SCALE 20 0 10 20 40 80 (IN FEET) 1 inch = 20 ft Know what's below CALL before you dig. co N L N I- oZ� y 0 CL 65 Cn i CO M Y a L —0 Mop �j SEAL 024457 Revised 8-4-23 by AWB z _o a U w C] oa w F- 0 O z w 0. m N O W N S _ L1 \ U � O O � oa � o� Q O z � r4�LO C] w � 0 w o rO N O a � x a o a ¢ 0 •py 0 0 O 0 0 � A � V 0 rT� Z O O Friday, August 4, 2023 1:30:09 PM _ 582, °8,• `- `3.7 58s 001 �' I I />< $, � 585 REINFORCED CONCRETE ENDWALL \ \LI I CSS ` I rn I i I I I nI II nI I 585- SEE DETAIL Ln M IM 584- roI NI rgI LO 00 Cb I _ — \ - sR \ 00 I I II I I I I I I I s8 SAND FILTER I I PROPOSED 8.0' x 16.0' CONCRETE RISER - -584— i I I _ � I I � � I DIAPHRAGM I I I w/ TRASH RACK, CREST ELEV: 586.00. 583- -----------\ \ I II I I I SEE I I I SEE RISER DETAIL 1 \ I I I I SE I I I I I I 8 \� \ — _ 00 —583 / — � �,\ II I II I I II I I I II I II I / r 581 \ C,In WA TE EXISTING - ,�00 582 say \ — \`s8� \ II I I II II II II I II I I I / SPOUT — _ — 580 I I ,. 00 I I LIMITS OF DISTURBANCE .� 5�g I 64 LF 60 in RCP i 580 I �'� I ---- s 1 +00 I I ;, a� 1 +80 I 2+00 2+20 I sao �— �i I II :E': _ ,`P kgp -s77 — _ _ — _ — ' / / I I; I I I I I^ ! 6" I _----`p —57s — �II I I II I II I I I 64 LF 60 in RCP i GATE 8 — - — — � ..579 ! 5�9 --/ -579— � r 09 - -- — —M•'i 8 ,..:.: VALVE I I LAKE DRAIN — — -579 r k6p _ �•--5 SEE 'LOW FLOW AREA" DETAIL 8 i ems--' 'y "•"9;--------- - I I I I I I —----------- __._,— — — — -----_— -- --__— —— _—— ---- -- --- 0+40 --578—-----0+20- 00 D 0 00 Go 0+00 I I j M� 31 I I I I I / / I I CONCRETE CRADLE TO � pp1 N I � / I I I INTEGRA S SLAB Doi aoi ao� ao� aoi ooi am am an — I 1 I I I I I I SPR NG LINE, SEEIDETAIL. ^ L 00 SEE RISER DETAIL ° �'� 1 LO% II II °In / I I LIMITS OF DISTURBANCE ` ��ti / � I I I \ I STONE BEDDING TO SPRING LINE. ITS OF DISTURBANCE MIN. 12" EITHER SIDE OF PIPE �I II l I #57 STONE, 12" MIN. DEPTH ` - / 00 i GRAPHIC SCALE 10 0 5 10 20 40 592 591 590 589 588 587 586 585 584 583 582 581 580 579 578 577 576 575 574 573 EXIS NG GRADE (CRE K �) NCDOT TYPE 2 FILTER FABRIC SLOPE AS NEEDED FOR PIPE COVER BEHIND HEADWALL / 2' MIN. ,; EXISTING \ GRADE SAND FILTER DIAPHRAGM \ SEE DETAIL \ REINFORCED CONCRETE / ENDWALL / SEE DETAIL LINE SPILLWAY WITH CLASS "2" RIPRAP STONE 2.67 ft DEEP w/ NCDOT TYPE 2 FILTER FABRIC --------- ----- I I / S P RI N G L I N E CONCRETE SLOPED - -------------�- / TO PIPE INVERT I / ------ -- -- / INV:578.65- I. INV: 578.11 64 LF (2) 60 in RCP @ 0.82% I - -- — — ------------ \ / 1.01 ----------f------- ------------�-- LINE CHANNEL WITH CLASS "2" MIN. .1 I RIPRAP STONE 2.67 ft DEEP w/ NCDOT TYPE 2 FILTER FABRIC 0+00 0+20 0+40 0+60 SAND FILTER U DIAPHRAGM STON€ &E-DDING-TO-SPRIN LINE. SEE DETAIL NCDOT TYPE 2 MIN. 12" EITHER SIDE OF PIPE FILTER FABRIC 1457 STONE, 12" MIN. DEPTHI 0+80 1+00 1+20 Primary Outfall 1+40 1+60 (IN FEET) 1 inch = 10 ft TRASH RACK, SEE DETAIL SHEET # 7 PERM. WATER ELEV: 586.0 PROPOSED 8.0' x 16.0' CONCRETE RISER w/ TRASH RACK, CREST ELEV: 586.00. SEE RISER DETAIL STEM SUPPORT 6" GATE VALVE LAKE DRAIN SEE "LOW FLOW AREA" DETAIL \—INV:581.25 ---- EXISTING GRADE BOTTOM of LOW FLOW AREA: 579.90 .L INTEGRAL BASE SLAB SEE RISER DETAIL SPRING LINE. 12" MIN. DEPTH, SEE DETAIL. 1+80 0 10 20 GRID SCALE: 1"= 10' HORZ 2+00 0 1 2 GRID SCALE: 1"= 2' VERT 592 591 590 589 588 587 586 585 584 583 582 581 580 579 578 577 576 575 574 573 2+20 Know what's below CALL before you dig. �� cn � Q a) CO C� (� F0 Z -�Zcfl i- U) � � M ac� � a, Y —0 _14 '���tttU ° �;� f � •r SEAL 024457 �,�9,F'►rGIN��G��ti,'L� z 0 a L) w 0 m w F- 0 0 z w al n N o w 0 o m < LO o Q ¢ Q o N o a 0 �I M M 111 0 00 00 PC O O 0 �I M E •R* ;Im-o w w C) o � Tuesday, June 20, 2023 9:06:56 AM 10, 18' f T ACCESS DOORS ON HINGES w/ LOCKABLE LATCH 2'-3" TRASH RACK DETAIL NOTES: F REMOVABLE GATE VALVE HAND WHEEL IINGED ACCESS DOOR WITH LOCK AND KEY -LINED UP WITH STEPS HOST STRUCTURE INFORMATION PART NUMBER LENGTH 18ft WIDTH loft ^12 WALL THICKNESS (REQ'D) in—� AVAILABLE OPTIONS "L" CHANNEL STEEL CROSS BRACING REMOVABLE ACCESS HATCH HDPE ANTI -VORTEX PLATE I X VOTES: 1. GABLE END SHOULD BE SHORTER END WHEN MEASURING. 2. MEASUREMENT CHANGES WILL OCCUR WHEN ACCESS DOOR IS NEEDED AND LADDER PLACEMENT IS DETERMINED. 1. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OR STANDARD DETAIL FOR APPROVAL. 2. TRASH RACK SHALL BE PEAKED -ROOF TOP MOUNT AS SHOWN ABOVE. SEE RISER DETAIL FOR RISER STRUCTURE DIMENSIONS. 3. TRASH RACK SHALL INCLUDE A HINGED ACCSS DOOR TO BE LOCATED AT STEPS TO ALLOW ACCESS INSIDE RISER STRUCTURE. LOCATION SHALL NOT INTERFERE WITH PIPE ENTRANCE AND GATE VALVE LOCATIONS. SEE RISER DETAIL FOR LOCATIONS. 4. TRASH RACK SHALL INCLUDE ANTI -VORTEX PLATE. 5. TYPICAL GRATE OPENINGS SHALL BE 9"X 9". 6. TRASH RACK SHALL BE CONSTRUCTED WITH STAINLESS STEEL OR ALUMINUM. TRASH RACK DETAIL NOT TO SCALE p m a NOTES: INSTALL ALL STEPS PROTRUDING 4" FROM INSIDE FACE OF STRUCTURE WALL. O� >_ < STEPS DIFFERING IN DIMENSIONS, CONFIGURATION, OR MATERIALS FROM THOSE SHOWN MAY ALSO BE USED PROVIDED THE CONTRACTOR HAS FURNISHED Q < H Z THE ENGINEER WITH DETAILS OF THE PROPOSED STEPS AND HAS RECEIVED WRITTEN APPROVAL FROM THE ENGINEER FOR THE USE OF SUCH STEPS. >"0m Hc50 I �<<D Z=�=Zm Op o F_0� 1 -LU0p c7��D cAF—LLOJ H OOcncr D D :� �Q - �� • z H\ O p „ 'Y8 T n\� / cm r w O 1� PL SIDE NATION PLAN SIDE ELEVATION _ N mm �� T CA u Z�I� 1'-0" 14 N a _I CAST IRON Z W ELEVATION W m H D 191s,� o v O 0 _ r 1 „ 8� n _ 11/4 " 'ao #6 BAR OR #8 BAR Q v I 1 i „ rn GALV' D. Z y O C ao �y� mZ = _ u,W \ N T �a ~ Z PLAN POLYPROPYLENE SIDE PLASTIC J C7 ~ 'a z CA �$„ Y2 - � � ELEVATION COMPOSITE PLAN ELEVATION SIDE wCC r � C 1/ „ ih REINFORCING STEEL 12" ELEVATION NOTE: #3 DEFORMEDC 12 _ DO NOT USE IN STEEL ROD SECTION A -A �� ELEVATION SANITARY SEWER MANHOLES. SHEET 1 OF 1 SHEET 1 OF 1 840.66 840.66 NOT TO SCALE 20' 0' 2' Tnr% \ /1 r%A/ TRASH STAINLESS STEEL VALVE STEM w/ WHEEL RACK TOP. PROVIDE MANUFACTURER APPROVED STEM GUIDES, SPACED PER MANUFACTURERS RECOMENDATIONS 8' 1' . #5 REBAR @ 12" O.C. FULL LENGTH OF RISER BOTH WAYS. (NOT SHOWN FOR CLARITY) ----- STAIR, 60" RCP TYP. 1 (2) STEM GUIDES OUTFALL 6" DIP LAKE 6" MJ GATE VALVE DRAIN a GROUT �• . 2'-2" FLEXIBLE WATERTIGHT RUBBER GASKET CONCRETE CRADLE, FLOW FOR DIP TO CONCRETE RISER CONNECTION SEE DETAIL THIS SHEET . - 1' .. . l' g 6 KEEP REBAR - III _ ° - - - 3" FROM EDGE GROUT AREA BENEATH PIPE BETWEEN CRADLE I- 13 - #5 REBAR EVENLY SPACED. , I ANDRISERRISER'- 12' SIDE VIEW 6" DIP LAKE DRAIN PIPE r-- 90' BEND 6" DIP ELEV: 442.0 STRAINER / TRASH GUARD SEE DETAIL TRASH RACK 16' STAIR, #5 REBAR @ 12" O.C. /�—�\ /�—�\P FULL LENGTH OF RISER / / — \ 6" MJ / \ BOTH WAYS. / GAT,t VALVE 60" RCP �I �I / / 60" RCP �I �I 8`1y4" OUTFALL OUTFALL 1 1 GROUT \ INVERT i \ INVERT $...: /. KEEP REBAf 4 . J 1'-16 3" FROM EDGI= <. Q I -III III III-1-1 I I-1 — _ — 21 - #5 REBAR EVENLY SPACED. I —III I I - CONCRETE RISER DETAIL 0 1 2 SCALE: 1/4" = 1' LOW AREA BELOW LAKE DRAIN. 8' x 8' MIN, 2' BELOW LAKE BOTTOM GRADE CLASS "A" RIPRAP 12" DEPTH 6" DEPTH OF #57 STONE NCDOT TYPE II NON -WOVEN GEOTEXTILE FABRIC LOW FLOW AREA AT LAKE DRAIN \1OT TO SCALE FRONT VIEW GALVINIZED HARDWARE CLOTH, MIN 19 GAUGE, MAX. 2" OPENINGS DIP FILLER FLANGE ATTACHED WITH 6" DIP LAKE GALVINIZED STEEL DRAIN PIPE BOLTS 0 0 0 0 0 (__�O O O 0 0 O 0 6" DIP STRAINER / VARM IT GAU RD NOT TO SCALE Know what's below CALL before you dig. cm m Q -� 0 Q) zT e0 N CC = (6 rn Urn y �oft CL 2 rn WD r� M C v Y a SEAL - - 024457Of z 0 a u w C� m w F- d C� O z w m n N N J U Q v N N o w z N v N N m m Q N J p oa (2) m Q Q > N o a wa a A � A SPRINGLINE I 60" RCP �� � I 60" RCP OUTFALL I a4 4 OUTFALL I 4 a 4 J 2 - #5 REBAR EVENLY SPACE CONTINUOUS a 4 \ MONOTYTHIC \ i VERTICALLY 4 ° i / ° CONCRETE CRADLE --� 4 3,000PSI MIN. 4. / 4 4 aJ /° 4 4 4 ° J a 4 4 � a2t°. 4 1' 1' #4 REBAR 17 - #5 REBAR DOWELS & HOOKS @ 12" O.C. @ 12" OTC HOLD BARS 3" CLEAR FROM SIDES & BOTTOM 17'-6" MONOLYTHIC CONCRETE CRADLE DETAIL 0 2 4 SCALE: 1 /2" = 1' SAND FILTER C33, MAXIMUM 3% FINES 4.5' :.. .. :•: .ice �`�' •• .. .• �� ��'•• .. 60" 60" RCP ` RCP CONCRETECRADLE _ .. 2.0' _ .. 25.5' FRONT VIEW OUTLET CONDUIT 60" 0 RCP FLOW NOTES: 1. CONTRACTOR TO PROVIDE OWNER'S TESTING AGENCY WITH A SAMPLE OF C-33 SAND FOR GRADATION TESTING IN ADVANCE OF CONSTRUCTION. 2. PLACE SAND WITH CLEAN CONSTRUCTION EQUIPMENT. 3. WET SAND IN -PLACE AND LIGHLTY TAMP WITH HAND-HELD TAMPER. 4. EXTEND SAND FILTER MIN. 2' BEYOND CONCRETE CRADLE. SEE PROFILE SHEET #6 Do 2.0' MIN 5.0' Min. SECTION VIEW SAND FILTER DIAPHRAGM DETAIL N0 0 CCAI SAND FILTER C33, MAXIMUM 3% FINES FLU 598 596 594 592 590 588 586 584 0+00 / SPRINGLINE 2 - #5 REBAR EVENLY SPACE CONTINUOUS VERTICALLY TWO PIPES 8' 9" 2 1/6 THREE PIPES 13'-0111 1 1 is "— I � 1 I � I 124 co w //I d7l/4" 4'-3,r TWO cPIPES�8'-6 THREE3 N1�IPIPES T4 I13�g" 3- N2- 2'-7%2" T2 OR T3 TOP & BOTTOM T5 @ 6" TOP & BOTTOM 5 SPA. @ 11" "Z' BARS IN TOP OF FOOTING 1 /Z2 co V1 @ 1'-4" @ WING WALL 511 Z3 5 SPA. @ 11" "N" BARS IN BOTTOM OF FOOTING PLAN 17'-6" TWO PIPES 26'-0" THREE PIPES N 2-V1 @ V-6" N 2-G2 OR G3 T STR. FACE T 2-V1 @ 9" FILL FACE B 2-B1 1-V1 STR. FACE 2-B2 10 I �� I 3" DRAINS F III ABOVE o LOW LINE 2 r,G„ 2'= SEE STD. # 838.45 FOR GENERAL NOTES. Irr 10 " 2" 2 FILL FACE II �2 FILL FACE V1 @ 9" „ ,V"@ 1'-6" @ WING WALL PIPE NOT , 6„ SHOWN 1 I T4 T4 N 6 -"T" � 8" L_ T5 @ 6" _ 8„ 3r-0,r SECTION - AA SECTION - BB Z O Cn F— r Q Q iZ-1 p~C (='3 . LLj CL 0 0 21)cc _ LU<<LL= QU=OH H Cl—LLOJ n OOCncr Q F— H 0 O BILL OF MATERIAL FOR ENDWALL LU J Y J U) a o O O C O LL O Z z W W F-I W f-I Q U LL- U _ 0 („� � REINF. STEEL 2 PIPES 3 PIPES BAR SIZE LENGTH NO. WEIGHT NO. WEIGHT B1 #4 5'-6" 8 29 12 44 B2 #4 4'-g" 4 12 4 12 B3 #4 6'- 6" 4 17 8 35 G2 #7 17'-2" 2 70 - - G3 #7 25' - 8" - - 2 105 H1 #4 6'-0" 10 40 10 40 H2 #4 4'-0" 4 11 4 11 N1 #4 3'-11" 14 57 18 74 — �` 1— — 5 SPA. @ 11" FILL N2 #4 3'-5" 6 14 6 14 Q Z Err I 6" 1„ FACE 2-V2, 2-V3, 2-V4 O LU 0 2 SPA. @ 1 10/2 STR. J CONST. JT. 2_B3 2-g1 4-N1 FACE 2-H1, 1-H2 Q V Q 4 N1 H2 T1 #4 21' 2" 6 85 - B 3 SPA. @ V-3" FILL 2 SPA. @ 1'-10" T2 #4 29'-8" 6 119 F- 0 FACE 3-H1, 1-H2 V2 STR. FACE } Z ELEVATION 1-V2, 1 -V3, 1 -V4 06 T4 #4 5' - 6" 6 22 6 22 < CC I V4 T5 #4 2'-6" 70 117 104 174 p C LU z 3' 9" 7 V4 V1 #4 6' 3" 12 50 18 75 Q Z CO z Z1 3%2" H1 V2 #4 5'-1" 6 20 6 20 D Z2 3'-3" 7" V3 #4 3'-11" 6 16 6 16 W 0 o _ _ V4 #4 2' 9" 6 11 6 11 N N Z3 2'-8r, 6 N N "Z„ Z1 #5 4'-4" 4 18 4 18 O H2� �r HK. T4 Z3 #4 33, 10 4 2" 4 18 4 '0 LL r ,r 1 1 I I � 3-N1 3-N2 -� �- 5 SPA. @ 11" "H" BARS "N" BARS "Z" BARS BARS "H", "N", & "Z' BAR DIMENSIONS ARE OUT TO OUT. WING ELEVATION REINF. STEEL LBS. 607 808 SHEET 1 OF 2 NOT TO SCALE CON./R.C. CU. YDS 7.9 9.9 838.28 5.5' NEW Q 7.0' NEW ADA COMPLIANT 40' BRIDGE SPAN ADA COMPLIANT ASPHALT ASPHALT BRIDGE DECK ELEV: 591.33' EXISTING ASPHALT TOP OF DAM - — — — — — — — — — — — — — — — — — 1 GRADE= 4.47% GRADE= 3.92% EXISTING — - BOTTOM BRIDGE BEAM ELEV: 590.5' 2'1 Q Q� 21 --- FILL � FILL / __-- CUT 25' SPILLWAY WEIR ELEV: 587.5' 0+20 PEDESTRIAN BRIDGE NOTES - 1. CONTRACTOR SHALL SUBMIT CONCEPT PLANS FOR APPROVAL FOR A PREFABRICATED PESESTRIAN BRIDGE AND ALSO SUBMIT FINAL SHOP DRAWINGS FOR APPROVAL. 2. SUBMITTAL SHALL INCLUDE A PE STAMPED DESIGN PACKAGE AND INCLUDE ALL STRUCTURAL ENGINEERING ASSOCIATED WITH THE BRIDGE. 3. BRIDGE WIDTH BETWEEN RAILS SHALL BE AT LEAST 8 FEET. 4. PEDESTRIAN BRIDGE SHALL SPAN THE EMERGENCY SPILLWAY SHOWN ON PLANS. SPILLWAY HAS A CREST ELEVATION OF 587.5 FOR A CREST LENGTH OF 25 LINEAR FEET AND SLOPED SIDES AT 2 TO 1 TO GRADE. SEE PROFILE PROVIDED. 5. LOWEST BRIDGE STRUCTURE ELEVATION SHALL BE AT OR ABOVE 590.5. 6. TRANSITION BETWEEN BRIDGE DECK AND ADJACENT ASPHALT PATH SHALL BE ADA COMPLIANT. 7. BRIDGE SHALL INCLUDE 42" HORIZONTAL SAFETY RAILING. 8. BRIDGE STRUCTURE SHALL BE CONSTRUCTED WITH WEATHERING STEEL. 2x PRESSURE TREATED PINE IS ACCEPTABLE FOR DECKING. 0+40 EMERGENCY SPILLWAY WEIR AND BRIDGE CCA_C: I" 4' 0+60 r� 10, -1 Tj3.5' BRIDGE DECK ELEV: 591.33' BOTTOM of BEAM ELEV: 590.5' 10" DEPTH FOR BRIDGE BEAM & DECK SECTION A - A HANDRAIL 598 596 594 592 590 588 586 584 0+80 Know what's below CALL before you dig. � Q Q) e0 N CC = M U rn rn WD � - M M � v Y a ,0�Ul 1`I I ■ SE 024457 z 0 F- a u C� m F- n 0 z z c� U v o 0 z � N co CD m m Q m z QL > o a O � O O O A 0 ROCK CHECK DAM IMPERVIOUS DIKE (SEE PROJECT SPECIAL PROVISIONS) TEMPORARY PIPING PUMP AROUND PUMP EXISTING GROUND SPECIAL STILLING BASIN FILTER FABRIC FOR DRAINAGE TYPE 2 (NON -WOVEN) SPECIAL STILLING BASIN (SEE PROJECT SPECIAL PROVISIONS) EWATERING PUMP TEMPORARY FLEXIBLE HOSE EXISTING CHANNEL �--IMPERVIOUS DIKE (SEE PROJECT 0 SPECIAL �2 PROVISIONS) SEQUENCE OF CONSTRUCTION FOR TYPICAL PUMP AROUND 1. INSTALL SPECIAL STILLING BASINS AT THE DOWNSTREAM END OF THE DESIGNATED PROJECT WORKING AREA. 2. THE CONTRACTOR WILL INSTALL THE PUMP AROUND PUMP AND THE TEMPORARY PIPING THAT WILL CONVEY THE BASE FLOW FROM UPSTREAM OF THE WORK SITE. 3. INSTALL UPSTREAM IMPERVIOUS DIKE AND BEGIN PUMPING OPERATIONS FOR STREAM DIVERSION. 4. INSTALL THE DOWNSTREAM IMPERVIOUS DIKE AND PUMPING APPARATUS IF NEEDED TO DEWATER THE ENTRAPPED AREA. THE PUMP AND HOSE FOR THIS PURPOSE SHALL BE OF SUFFICIENT SIZE TO DEWATER THE WORK AREA. THIS WATER WILL FLOW INTO A SPECIAL STILLING BASIN. 5. THE CONTRACTOR WILL PERFORM STREAM RESTORATION WORK IN ACCORDANCE WITH THE PLAN AND FOLLOWING THE GENERAL CONSTRUCTION SEQUENCE. 6. THE CONTRACTOR WILL EXCAVATE ANY ACCUMULATED SILT AND DEWATER BEFORE REMOVAL OF THE IMPERVIOUS DIKE. REMOVE IMPERVIOUS DIKES, PUMPS, AND TEMPORARY FLEXIBLE HOSE/PIPING STARTING WITH THE DOWNSTREAM DIKE FIRST. 7. ONCE THE WORKING AREA IS COMPLETED, REMOVE THE STILLING BASINS AND STABILIZE DISTURBED AREAS WITH SEED AND MULCH. NOTES: 1. EXCAVATION SHALL BE PERFORMED IN ONLY DRY SECTIONS OF CHANNEL. 2. IMPERVIOUS DIKES SHOULD BE USED TO ISOLATE WORK AREAS FROM STREAM FLOW. 3. THE CONTRACTOR SHALL NOT DISTURB MORE AREA THAN CAN BE STABILIZED IN ONE WORKING DAY. 4. PROVIDE STABILZED OUTLET TO STREAM BANK. 12" MIN. CLASS A STONE ,TOP OF STREAM BANK SANDBAG/STONE n BASEFLOW WORKING ` AREA J FLOW IMPERVIOUS SHEET PROVIDE STABILIZED OUTLET TO STREAM BANK TYPICAL PUMP AROUND OPERATION DO NOT USE CHECK DAMS IN INTERMITTENT OR PERENNIAL STREAMS CLASS B RIP A AND B ARE AT EQUAL ELEVATIONS PLAN CONSTRUCTION SPECIFICATIONS: 1. PLACE STONE TO THE LINES AND DIMENSIONS SHOWN IN THE PLAN ON A FILTER FABRIC FOUNDATION. 2. KEEP THE CENTER STONE SECTION AT LEAST 9 INCHES BELOW NATURAL GROUND LEVEL WHERE THE DAM ABUTS THE CHANNEL BANKS. 3. EXTEND STONE AT LEAST 1.5 FEET BEYOND THE DITCH BANK TO KEEP WATER FROM CUTTING AROUND THE ENDS OF THE CHECK DAM. 4. SET SPACING BETWEEN DAMS TO ASSURE THAT THE ELEVATION AT THE TOP OF THE LOWER DAM IS THE SAME AS THE TOE ELEVATION OF THE UPPER DAM. 5. PROTECT THE CHANNEL AFTER THE LOWEST CHECK DAM FROM HEAVY FLOW THAT COULD CAUSE EROSION. 6. MAKE SURE THAT THE CHANNEL REACH ABOVE THE MOST UPSTREAM DAM IS STABLE. 7. ENSURE THAT OTHER AREAS OF THE CHANNEL, SUCH AS CULVERT ENTRANCES BELOW THE CHECK DAMS, ARE NOT SUBJECT TO DAMAGE OR BLOCKAGE FROM DISPLACED STONES. REFERENCE: NCDENR PLANNING AND DESIGN MANUAL, JUNE 2006 NOT TO SCALE l'-6' MIN. I--1 CROSS SECTION I IMPERVIOUS DIKE /57 WASHED STONE CLOTH MAINTENANCE: INSPECT CHECK DAMS AND CHANNELS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. CLEAN OUT SEDIMENT, STRAW, LIMBS, OR OTHER DEBRIS THAT COULD CLOG THE CHANNEL WHEN NEEDED. ANTICIPATE SUBMERGENCE AND DEPOSITION ABOVE THE CHECK DAM AND EROSION FROM HIGH FLOWS AROUND THE EDGES OF THE DAM. CORRECT ALL DAMAGE IMMEDIATELY. IF SIGNIFICANT EROSION OCCURS BETWEEN DAMS ADDITIONAL MEASURES CAN BE TAKEN SUCH AS INSTALLING A PROTECTIVE RIPRAP LINER IN THAT PORTION OF THE CHANNEL. REMOVE SEDIMENT ACCUMULATED BEHIND THE DAMS AS NEEDED TO PREVENT DAMAGE TO CHANNEL VEGETATION, ALLOW THE CHANNEL TO DRAIN THROUGH THE STONE CHECK DAM, AND PREVENT LARGE FLOWS FROM CARRYING SEDIMENT OVER THE DAM. ADD STONES TO DAMS AS NEEDED TO MAINTAIN DESIGN HEIGHT AND CROSS SECTION. REVISIONS FILE: L/Maps-Details/Detail Manual/Details NO. DATE DESCRIPTION of y04� CITY OF MONROE DRAWN BY: DKO DATE: 04-20-04 TEMPORARYROCK CHECK I 0$/0$ UPDATED SPECIFICATIONS UNION COUNTY NOR PH CAROG[NA u CHECKED BY: JNL SCALE: N.T.S. PREPARED BY: c►aoENGINEERING DEPARTMENT DETAIL 03.12.01 INSTALLATION 1. LIFTING STRAPS SHALL BE PLACED UNDER THE FILTER BAG TO FACILITATE REMOVAL AFTER USE. 2. PLACE FILTER BAG ON A LEVEL STABILIZED AREA OVER GRAVEL. 3. INSERT DISCHARGE HOSE FROM PUMP INTO FILTER BAG A MINIMUM OF SIX INCHES (6") AND TIGHTLY SECURE WITH STRAP TO PREVENT WATER FROM FLOWING OUT OF THE BAG WITHOUT BEING FILTERED. 4. REPLACE THE UNIT WHEN ONE HALF (2) FULL OF SEDIMENT OR WHEN SEDIMENT HAS REDUCED THE FLOW RATE OF THE PUMP DISCHARGE TO AN IMPRACTICAL RATE. 5. MATERIAL REMOVED FROM SILT BAGS CAN BE SPREAD ON SITE AS LANDSCAPE MATERIAL AS LONG AS IT HAS BEEN ADEQUATELY DEWATERED SUCH THAT IT WILL NOT MIGRATE DOWNSLOPE WHEN PLACED. SILT BAG MATERIAL SHALL NOT BE USED AS BACKFILL OR PLACED WHERE STRUCTURAL MATERIAL IS REQUIRED. SIZE AND NUMBER OF FILTER BAGS BASED ON DEWATERING PUMPING RATE TIE DOWN STRAP PUMPED DISCHARGE FILTER BAG 4FLOW- W_ DEWATERING PUMP PUMP DISCHARGE HOSE FILTERED WATER DEWATERING WITH FILTER BAG DETAIL NOT TO SCALE SEEDING PREPARATION AREAS TO BE SEEDED SHALL BE THOROUGHLY LOOSENED AND WORKED TO A MINIMUM DEPTH OF AT LEAST 5 INCHES. THE AREA SHALL THEN BE RACKED OR OTHERWISE CLEARED OF ROCKS, LARGER THAN 2 INCHES IN DIAMETER, STICKS OR OTHER DEBRIS. FOR LATE WINTER AND SOIL AMENDMENTS; EARLY SPRING: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER SEEDING MIXTURE: MULCH; RYE (GRAIN) — 120 LB/ACRE APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANNUAL LESPEDEZA (KOBE) — 50 LB/ACRE ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING (OMIT ANNUAL LESPEDEZA WHEN DURATION TOOL OF TEMPORARY COVER IS NOT TO EXTEND BEYOND JUNE) MAINTENANCE: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, FERTILIZE AND MULCH IMMEDIATELY FOLLOWING SEEDING DATES: EROSION OR OTHER DAMAGE JAN. 1 — MAY 1 FOR SUMMER: SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER SEEDING MIXTURE: GERMAN MILLET — 40 LB/ACRE MULCH: (A SMALL —STEMMED SUDANGRASS MAY BE APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH SUBSTITUTED AT A RATE OF 50 LB/ACRE) ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING SEEDING DATES: TOOL MAY 1 — AUG. 15 MAINTENANCE: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, FERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE FOR FALL: SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 1,000 LB/ACRE 10-10-10 FERTILIZER SEEDING MIXTURE: RYE (GRAIN) — 120 LB/ACRE MULCH: APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH SEEDING DATES: ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING AUG. 15 — DEC 30 TOOL MAINTENANCE: REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOPDRESS WITH 50 LB/ACRE OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 LB/ACRE KOBE LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. FOR ADDITIONAL INFORMATION, REFER TO NCDENR EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL (ESCPDM), SECTION 6.10. FOR PERMANENT SEEDING SPECIFICATIONS, INCLUDING SEED BED PREP, SEASONAL LIMITATIONS FOR SEEDING OPERATIONS, THE KINDS OF GRADES OF FERTILIZERS, THE KINDS OF SEED, AND THE RATES OF APPLICATION OF LIMESTONE, FERTILIZER, AND SEED, REFER TO NCDENR ESCPDM SECTION 6.11 PLEASE CONSULT THE NATURAL RESOURCES CONSERVATION SERVICE FOR ADDITIONAL ALTERNATIVES FOR VEGETATING DENUDED AREA REVISIONS `Rq Op y0�8p "° u " C.aa� ® SEEDBED PREPARATION & TEMPORARY SEEDING CITY OF MONROE UNION COUNTY NORTH FILE: ENew_I/Maps-Details/Detail Manual&Specs/ Standard Detail & Spec Manual/Standard De[ai08- NO. DATE DESCRIPTION DRAWN BY: JAM DATE: 08-07-01 t a/zo/oa FORMATATED 2 01/2015 RE"sm nT PREPARED BY ENGINEERING DEPARTMENT CHECKED BY: JNL SCALE: N.T.S. DETAIL 03.07.01 Steel Gaurd Pipe with Locking Cap STANDARD PIEZOMETER DETAIL NOT TO SCALE Know what's below CALL before you dig. � Q N .� OO N i.r L N W �z Z� Q, co M a) C.) C a N U Y 0 A Mftuft lqqmmmp- SEAL 024457 Revised 8-4-23 by AWB z 0 F- a c� u w n m w d 0 0 z rj w m J M o w V p Z U v 00 o 0 m m Q LC) m Z a m a N a 0 fs� a 4-1 0 �O c� W w � �1_ O GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH THE NCGO1 CONSTRUCTION GENERAL PERMIT Implementing the details and specifications on this plan sheet will result in the construction activity being considered compliant with the Ground Stabilization and Materials Handling sections of the NCG01 Construction General Permit (Sections E and F, respectively). The permittee shall comply with the Erosion and Sediment Control plan approved by the delegated authority having jurisdiction. All details and specifications shown on this sheet may not apply depending on site conditions and the delegated authority having jurisdiction. SECTION E: GROUND STABILIZATION Stabilize within Site Area Description this many calendar Timeframe variations days after ceasing land disturbance aPerimeter I es, swales, ditches, and 7 None perimeter slopes (b) High Quality Water 7 None (HQW) Zones (c) Slopes steeper If slopes are 10 feet or less in than 3:1 7 length and are not steeper than 2:1 14 days are allowed -7 days for slopes greater than 50' in length and with slopes steeper than 4:1 -7 days for perimeter dikes, swales, (d) Slopes 3:1 to 4:1 14 ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed -7 days for perimeter dikes, swales, ditches (e) Areas with slopes perimeter slopes and HQW Zones flatter than 4:1 14 -10 days for Falls Lake Watershed unless there is zero slope Note: After the permanent cessation of construction activities, any areas with temporary ground stabilization shall be converted to permanent ground stabilization as soon as practicable but in no case longer than 90 calendar days after the last land disturbing activity. Temporary ground stabilization shall be maintained in a manner to render the surface stable against accelerated erosion until permanent ground stabilization is achieved. GROUND STABILIZATION SPECIFICATION Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of the techniques in the table below: Temporary Stabilization Permanent Stabilization • Temporary grass seed covered with straw o • Permanent grass seed covered with straw other mulches and tackifiers. or other mulches and tackifiers • Hydroseeding • Geotextile fabrics such as permanent soil • Rolled erosion control products with or reinforcement matting without temporary grass seed • Hydroseeding • Appropriately applied straw or other mulch • Shrubs or other permanent plantings • Plastic sheeting covered with mulch • Uniform and evenly distributed ground cover sufficient to restrain erosion • Structural methods such as concrete, asphalt or retaining walls • Rolled erosion control products with grass seed POLYACRYLAMIDES (PAMS) AND FLOCCULANTS 1. Select flocculants that are appropriate for the soils being exposed during construction, selecting from the NC DWR List of Approved PAMS/Flocculants. 2. Apply flocculants at or before the inlets to Erosion and Sediment Control Measures. 3. Apply flocculants at the concentrations specified in the NC DWR List of Approved PAMS/Flocculants and in accordance with the manufacturer's instructions. 4. Provide ponding area for containment of treated Stormwater before discharging offsite 5. Store flocculants in leak -proof containers that are kept under storm -resistant cover or surrounded by secondary containment structures. QUIPMENT AND VEHICLE MAINTENANCE 1. Maintain vehicles and equipment to prevent discharge of fluids. 2. Provide drip pans under any stored equipment. 3. Identify leaks and repair as soon as feasible, or remove leaking equipment from the project. 4. Collect all spent fluids, store in separate containers and properly dispose as hazardous waste (recycle when possible). 5. Remove leaking vehicles and construction equipment from service until the problem has been corrected. 6. Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products to a recycling or disposal center that handles these materials. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1. Never bury or burn waste. Place litter and debris in approved waste containers. 2. Provide a sufficient number and size of waste containers (e.g dumpster, trash receptacle) on site to contain construction and domestic wastes. 3. Locate waste containers at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 4. Locate waste containers on areas that do not receive substantial amounts of runoff from upland areas and does not drain directly to a storm drain, stream or wetland. 5. Cover waste containers at the end of each workday and before storm events or provide secondary containment. Repair or replace damaged waste containers. 6. Anchor all lightweight items in waste containers during times of high winds. 7. Empty waste containers as needed to prevent overflow. Clean up immediately if containers overflow. 8. Dispose waste off -site at an approved disposal facility. 9. On business days, clean up and dispose of waste in designated waste containers. PAINT AND OTHER LIQUID WASTE 1. Do not dump paint and other liquid waste into storm drains, streams or wetlands. 2. Locate paint washouts at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 3. Contain liquid wastes in a controlled area. 4. Containment must be labeled, sized and placed appropriately for the needs of site. 5. Prevent the discharge of soaps, solvents, detergents and other liquid wastes from construction sites. PORTABLE TOILETS 1. Install portable toilets on level ground, at least 50 feet away from storm drains, streams or wetlands unless there is no alternative reasonably available. If 50 foot offset is not attainable, provide relocation of portable toilet behind silt fence or place on a gravel pad and surround with sand bags. 2. Provide staking or anchoring of portable toilets during periods of high winds or in high foot traffic areas. 3. Monitor portable toilets for leaking and properly dispose of any leaked material. Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace with properly operating unit. EARTHEN STOCKPILE MANAGEMENT 1. Show stockpile locations on plans. Locate earthen -material stockpile areas at least 50 feet away from storm drain inlets, sediment basins, perimeter sediment controls and surface waters unless it can be shown no other alternatives are reasonably available. 2. Protect stockpile with silt fence installed along toe of slope with a minimum offset of five feet from the toe of stockpile. 3. Provide stable stone access point when feasible. 4. Stabilize stockpile within the timeframes provided on this sheet and in accordance with the approved plan and any additional requirements. Soil stabilization is defined as vegetative, physical or chemical coverage techniques that will restrain accelerated erosion on disturbed soils for temporary or permanent control needs. HAZARDOUS AND TOXIC WASTE 1. Create designated hazardous waste collection areas on -site. 2. Place hazardous waste containers under cover or in secondary containment. 3. Do not store hazardous chemicals, drums or bagged materials directly on the ground. ONSITE CONCRETE WASHOUT STRUCTURE WITH LINER A �P IC 1 ACTUAL LOCATION D o CD O 1:1 LI I DETERMINED IN FIELD O O FENCE SIDE SLOP SANDBAGS (TYP.) (TYP, OR STAPLES 2. THE CONCRETE WASHOUT O O STRUCTURES SHALL BE MAINTAINED WHEN THE LIQUID O O 3 -0 AND/OR SOLID REACHES 75% OF THE STRUCTURES CAPACITY. O O o O SANDBAGS (TYP.) & X' A OR STAPLES MAX, 3.CONCRETE WASHOUT SECTION A -A BELOW GRADE WASHOUT STRUCTURE STRUCTS TO BE CLEARYUMARKED RE DWITH SIGNAGE NOT TO SCALE NOTING DEVICE. j0{yjjjj..� F}E ION �OIBEM CONCRETE WASHOUT CLEARLY MARKED SIGNAGE NOTING DEVICE (18"X24" MIN.) 1. ACTUAL LOCATION 0' DETERMINED IN FIELD B SANDBAGS (TYP.)10 O CD CD O MIL OR STAPLES P ASTIC LINING `WTION 2. THE CONCRETE WASHOUT STRUCTURES SHALL BE 1:1 SIDE MAINTAINED WHEN THE LIQUID O O SLOPE AND/OR SOLID REACHES 75% OF O O (TYP.) THE STRUCTURES CAPACITY TO 10' MIN PROVIDE ADEQUATE HOLDING O O CAPACITY WITH A MINIMUM 12 O 3_0• INCHES OF FREEBOARD. o MIN. , X' MAX. 3.CONCRETE WASHOUT B SANDBAGS (TYP.) STRUCTURE NEEDS TO BE SECTION B-BOR STAPLES CLEARY MARKED WITH SIGNAGE NOTING DEVICE. ABOVE GRADE WASHOUT STRUCTURE CONCRETE WASHOUTS 1. Do not discharge concrete or cement slurry from the site. 2. Dispose of, or recycle settled, hardened concrete residue in accordance with local and state solid waste regulations and at an approved facility. 3. Manage washout from mortar mixers in accordance with the above item and in addition place the mixer and associated materials on impervious barrier and within lot perimeter silt fence. 4. Install temporary concrete washouts per local requirements, where applicable. If an alternate method or product is to be used, contact your approval authority for review and approval. If local standard details are not available, use one of the two types of temporary concrete washouts provided on this detail. 5. Do not use concrete washouts for dewatering or storing defective curb or sidewalk sections. Stormwater accumulated within the washout may not be pumped into or discharged to the storm drain system or receiving surface waters. Liquid waste must be pumped out and removed from project. 6. Locate washouts at least 50 feet from storm drain inlets and surface waters unless it can be shown that no other alternatives are reasonably available. At a minimum, install protection of storm drain inlet(s) closest to the washout which could receive spills or overflow. 7. Locate washouts in an easily accessible area, on level ground and install a stone entrance pad in front of the washout. Additional controls may be required by the approving authority. 8. Install at least one sign directing concrete trucks to the washout within the project limits. Post signage on the washout itself to identify this location. 9. Remove leavings from the washout when at approximately 75% capacity to limit overflow events. Replace the tarp, sand bags or other temporary structural components when no longer functional. When utilizing alternative or proprietary products, follow manufacturer's instructions. 10. At the completion of the concrete work, remove remaining leavings and dispose of in an approved disposal facility. Fill pit, if applicable, and stabilize any disturbance caused by removal of washout. HERBICIDES, PESTICIDES AND RODENTICIDES 1. Store and apply herbicides, pesticides and rodenticides in accordance with label restrictions. 2. Store herbicides, pesticides and rodenticides in their original containers with the label, which lists directions for use, ingredients and first aid steps in case of accidental poisoning. 3. Do not store herbicides, pesticides and rodenticides in areas where flooding is possible or where they may spill or leak into wells, stormwater drains, ground water or surface water. If a spill occurs, clean area immediately. 4. Do not stockpile these materials onsite. NCG-01 GROUND COVER & MATERIALS HANDLING PART II, SECTION G, ITEM (4) DRAW DOWN OF SEDIMENT BASINS FOR MAINTENANCE OR CLOSE OUT Sediment basins and traps that receive runoff from drainage areas of one acre or more shall use outlet structures that withdraw water from the surface when these devices need to be drawn down for maintenance or close out unless this is infeasible. The circumstances in which it is not feasible to withdraw water from the surface shall be rare (for example, times with extended cold weather). Non -surface withdrawals from sediment basins shall be allowed only when all of the following criteria have been met: (a) The E&SC plan authority has been provided with documentation of the non -surface withdrawal and the specific time periods or conditions in which it will occur. The non -surface withdrawal shall not commence until the E&SC plan authority has approved these items, (b) The non -surface withdrawal has been reported as an anticipated bypass in accordance with Part III, Section C, Item (2)(c) and (d) of this permit, (c) Dewatering discharges are treated with controls to minimize discharges of pollutants from stormwater that is removed from the sediment basin. Examples of appropriate controls include properly sited, designed and maintained dewatering tanks, weir tanks, and filtration system (d) Vegetated, upland areas of the sites or a properly designed stone pad is used to the extent feasible at the outlet of the dewatering treatment devices described in Item (c) above, (e) Velocity dissipation devices such as check dams, sediment traps, and riprap are provided at the discharge points of all dewatering devices, and (f) Sediment removed from the dewatering treatment devices described in Item (c) above is disposed of in a manner that does not cause deposition of sediment into waters of the United States. PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION A: SELF -INSPECTION Self -inspections are required during normal business hours in accordance with the table below. When adverse weather or site conditions would cause the safety of the inspection personnel to be in jeopardy, the inspection may be delayed until the next business day on which it is safe to perform the inspection. In addition, when a storm event of equal to or greater than 1.0 inch occurs outside of normal business hours, the self -inspection shall be performed upon the commencement of the next business day. Any time when inspections were delayed shall be noted in the Inspection Record. Inspect Frequency Inspection records must include: (during normal business hours Daily rainfall amounts. (1) Rain gauge Daily maintained in If no daily rain gauge observations are made during weekend good working on holiday periods, and no individual -day rainfall information is order available, record the cumulative rain measurement for those unattended days (this will determine if a site inspection is needed). Days on which no rainfall occurred shall be recorded as "Zero." The permittee may use another rain -monitoring device approved by the Division. 1. Identification of the measures inspected (2) E&SC At least once per 7 Measures calendar days and 2. Date and Time of the inspection within 24 hours of 3. Name of the person performing the inspection a rain event >_ 1.0 4. Indication of whether the measures were operating properly inch in 24 hours. 5. Description of maintenance needs for the measure 6. Description, Evidence, and date of corrective actions taken (3) Stormwater At least once per 7 1. Identification of the discharge outfalls inspected discharge 9 calendar days and Y 2. Date and Time of the inspection p outfalls(SDOs) within 24 hours of 3. Name of the person performing the inspection a rain event >_ 1.0 4. Evidence of indicators of stormwater pollution such as oil inch in 24 hours. sheen, floating or suspended solids or discoloration 5. Indication of visible sediment leaving the site 6. Description, Evidence, and date corrective actions taken (4) Perimeter At least once per 7 If visible Sedimentation is found outside site limits, then record of Site calendar days and of the following shall be made: within 24 hours of 1) Actions taken to clean up or stabilize sediment that has left a rain event >_ 1.0 the site limits inch in 24 hours. 2) Description, Evidence and date of corrective actions taken 3) An explanation as to the actions taken to control future releases (5) Streams or At least once per 7 If the stream or wetland has increased visible sedimentation or wetlands calendar days and has visible increased turbidity from the construction activity, then onsite or within 24 hours of a record of the following shall be made: offsite (where a rain event >_ 1.0 1) Description, Evidence and date of corrective actions taken accessible) inch in 24 hours. 2)Records of required reports to the appropriate Division Regional Office per Part III, Section C, Item(2)(a) of this permit (6) Ground After each phase 1. The phase of grading (installation of perimeter E&SC Stabilization of grading. measures, clearing and grubbing, installation of storm Measures drainage facilities, completion of all land -disturbing activity, construction or redevelopment, permanent ground cover). 2. Documentation that the required ground stabilization measures have been provided within the required timeframe or assurance that they will be provided as soon as possible. NOTE: The rain Inspection resets the reauired 7 calendar dav InSDectlon reaulrement. PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION B: RECORDKEEPING 1. E&SC Plan Documentation The approved E&SC plan as well as any approved deviation shall be kept on the site. The approved E&SC plan must be kept up-to-date throughout the coverage under this permit. The following items pertaining to the E&SC plan shall be kept on site and available for inspection at all times during normal business hours. Item to Document Document Requirements Initial and date each E&SC measure on a copy of (a) Each E&SC measure has been installed and the approved E&SC plan or complete, date and does not significantly deviate from the locations, sign an inspection report that lists each E&SC dimensions and relative elevations shown on the measure shown on the approved E&SC plan. This approved E&SC plan. documentation is required upon the initial installation of the E&SC measures are modified after initial installation. (b) A phase of grading has been completed. Initial and date a copy of the approved E&SC plan or complete, date and sign an inspection report to indicate completion of the construction phase. (c) Ground cover is located and installed in Initial and date a copy of the approved E&SC plan accordance with the approved E&SC plan. or complete, date and sign an inspection report to indicate compliance with approved ground cover specifications. (d) The maintenance and repair requirements for Complete, date and sign an inspection report. all E&SC measures have been performed. (e) Corrective actions have been taken to E&SC Initial and date a copy of the approved E&SC plan measures. or complete, date and sign an inspection report to indicate the completion of the corrective action. 2. Additional Documentation to be Kept on Site In addition to the E&SC plan documents above, the following items shall be kept on the site and available for inspectors at all times during normal business hours, unless the Division provides a site -specific exemption based on unique site conditions that make this requirement not practical: (a) This General Permit as well as the Certificate of Coverage, after it is received. (b) Records of inspections made during the previous twelve months. The permittee shall record the required observations on the Inspection Record Form provided by the Division or a similar inspection form that includes all the required elements. Use of electronically -available records in lieu of the required paper copies will be allowed if shown to provide equal access and utility as the hard -copy records. 3. Documentation to be Retained for Three Years All data used to complete the a-NOI and all inspection records shall be maintained for a period of three years after project completion and made available upon request. [40 CFR 122.41] NCG01- SELF INSPECTION PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION C: REPORTING 1. Occurrences that Must be Reported Permittees shall report the following occurrences: (a) Visible sediment deposition in a stream or wetland. (b) Oil spills if: • They are 25 gallons or more, • They are less than 25 gallons but cannot be cleaned up within 24 hours, • They cause sheen on surface waters (regardless of volume), or • They are within 100 feet of surface waters (regardless of volume). (c) Releases of hazardous substances in excess of reportable quantities under Section 311 of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA (Ref: 40 CFR 302.4) or G.S. 143-215.85. (d) Anticipated bypasses and unanticipated bypasses. (e) Noncompliance with the conditions of this permit that may endanger health or the environment. 2. Reporting Timeframes and Other Requirements After a permittee becomes aware of an occurrence that must be reported, he shall contact the appropriate Division regional office within the timeframes and in accordance with the other requirements listed below. Occurrences outside normal business hours may also be reported to the Department's Environmental Emeraencv Center personnel at (800) 858-0368. Occurrence Reporting Timeframe (After Discovery) and Other Requirements (a) Visible • Within 24 hours, an oral or electronic notification. sediment • Within 7 Calendar Days, a report that contains a description of the deposition in a sediment and actions taken to address the cause of the deposition. stream or wetland Division staff may waive the requirement for a written report on a case - by -case basis. • If the stream is named on the NC 303(d) list as impaired for sediment - related caused, the permittee may be required to perform additional monitoring, inspections or apply more stringent practices if staff determine that additional requirements are needed to assure compliance with the federal or state impaired -waters conditions. b Oils ills and • Within 24 Hours an oral or electronic notification. The notification shall release of include information about the date, time, nature, volume and location hazardous of the spill or release. substances per item 1(b)-(c) above (c) Anticipated • A report at least ten days before the date of the bypass, if possible. bypasses [40 CFR The report shall include an evaluation of the anticipated quality and 122.41(m)(3)] effect of the bypass. (d) Unanticipated • Within 24 Hours, an oral or electronic notification bypasses [40 CFR • Within 7 calendar days, a report that includes an evaluation of the 122.41(m)(3)] quality and effect of the bypass. (e) Noncompliance • Within 24 Hours, an oral or electronic notification with the conditions • Within 7 calendar days, a report that contains a description of the of this permit that noncompliance, and its causes; the period of noncompliance, including may endanger exact dates and times, and if the noncompliance has not been health or the corrected, the anticipated time noncompliance is expected to continue; environment [40 and steps taken or planned to reduce, eliminate and prevent CFR 122.41(I)(7)] reoccurrence of the noncompliance. [40 CFR 122.41(1)(6). • Division staff may waive the requirement for a written report on a case - by -case basis. Know what's below CALL before you dig. � Q Q) i o0 �Nrn Urn CC (6 rn y CO CO C, E a Y ,01111 SEAL 024457 - 41`- N..... z 0 a u r� C� m d O z r� z J U n C� N o C1\i Z U � c 0 CD m m Q J p m Z � m Q Q c\J 0 a a A O O LIJ O O 0