HomeMy WebLinkAboutSW3230303_BUA Allocations_20230803 \ / / \ /
L NOTES:
1. EXISTING BUA SHOWN BASED ON AN INSTALLATION
� i `
\ DATE OF JULY 1,2007 PER NCDEQ REQUEST.
PROPOSED BUA CATEGORIES SHOWN INCLUDES
/ 2 / BUA INSTALLED AFTER JULY 1,2007 AND BUA
S
/'/:' I/ ASSOCIATED WITH THIS PROJECT AS SHOWN IN
/ / NG
• THE CONTRACT DRAWINGS.
FACILITY STATION\ �\
( ® FLUENT \ \ —
__
�� TAT PUMP ION 1 \ \ /' I �Z�
f---- 7
y;.,.•.,_ INFLUENT
'ELECTRICAL \ /
�INFLUENT � �;•• BUILDI G \ I TOTAL IMPERVIOUS AREA(AC): 7.98
/ JUNCTION i- I I I TOTAL PROJECT AREA(AC): 53.24
BOX �I;n I1. \ \\ /' ///I I PROJECT%IMPERVIOUS: 15.0%
ODOR CONTROL- ''} ,�"• i IMPERVIOUS SURFACE AREA DRAINAGE AREA
INFLUENT ON-SITE BUILDINGS/LOTS(SF) 31,300
\,\ )�� ON-SITE STREETS(SF) 62,570
\11 ON-SITE SIDEWALKS(SF) 8,320
STANDBY
,E RRATOR . OFF-SITE(SF) 0
R OC TA ED S ND Y / EXISTING BUA(SF) 245,430
GENE T R \ TOTAL(SF) 347,620
•
l� \� LEGEND:
BREAKDOWN OF PROPOSED BUA \ \. IM OµN _
+ .04G�N BLOWER BUILDING \�\�
\CE `\ ��� \�\ PROPOSED STRUCTURE
SQUARE FOOTAGES(IMPERVIOUS) ''\ \\\` _� STANDBYPOWER \
GENERATOR 'O`��O®O®O®O®O®O®O®O®O` I 00000;
<� `___ FILTRATE PUMP a.4�0d00 71t� ;:, 1 0000••'
>000••� PROPOSED PAVEMENT
ON-SITE BUILDINGS/LOTS BUA STATION „�000/ ®J ®O./..e00a�o�.o �001w�.
ODOR CONTROL-SOLIDS 0 D I D T•�i ®,/,
F
INFLUENT PUMP STATION 2 2,200 SF �6` ~ _ ' _7 gERATI Ilk \ \\\\
GRIT REMOVAL FACILITY 4,000 SF .' R� _/ a®$ " 1\ .. �e ® N \`\ PROPOSED PERVIOUS STRUCTURES
..7 : ON TANK 6 O \�``\:
DISTRIBUTION STRUCTURE 1,200 SF \ \ 00 - . SECONDARY SECONDARY 90< \\��`��� PROPOSED SIDEWALK
' '- ELECTRICAL \\\`2\
SOLIDS
o _ ANDLING,-) �!CLARIFIER 5 e 0� BUILDING 5
ODOR CONTROL-GRIT 1,200 SF -. </ !• \ / \ N 1----- i L AERATION TANK 5� O@ \\ \ \ \ I I ( ,I
/ ` CLARIFIERfi A IL
00''a DIGESTER �\\ DIGESTER �� ODOR CONTROL- EXISTING
ELECTRICAL BUILDING 5 550 SF \\ L°0° \ \ / ELECTRICAL b��� GRIT • •
\�// (/ h� BUILDING �e` DISTRIBUTION
BLOWER BUILDING 3,600 SF ` ` r " ' ��� STRUCTURE
;F..r i��i •1 \ SECONDARY DISS f
RAS PUMP STATION B 800 SF BLOWER BUILDING 3 • CLARIFIER 4 ,,..,E7 DISTRIBUTION % 1
BLOWER BUILDING 2 I® �- BOX 0 II 1
CHEMICAL FACILITY 1,650 SF g g� - - ELECTRICAL p
/ �IlN DIGESTER1 0d _ 1_ - '� BUILDING3 ett06gi \ GRIT REMOVAL
SOLIDS HANDLING BUILDING 6,200 SF / ELECTRICAL BUILDING 2 AERATION TANK 2 00 .\ FACILITY
SECONDARY SECONDARI �\
BLOWER BUILDING 1 _-11
ODOR CONTROL-SOLIDS 9,900 SF • O I���a CLARIFIER.2 CLARIFIER 1 CIILITY L •/� • rl
IILILRSI / �.� -AERATION TANKI v
CASCADE AERATOR p --\,,,,_ i ( �:
I
ON-SITE STREETS BUA • _ (`
NEAR INFLUENT AREA 1,100 SF A_:477
ULTRAVIOLET
NORTHWEST OF SITE 31,370 SF ` ' _ J I
•
Y DISINFECTION 0 I
NEAR CHEMICAL FACILITY 1,600 SF \\ FILTER 0 ✓,P
)I
ELECTRICAL I
EAST OF FILTERS 14,500 SF BUILDING
141
1 ADMINISTRATION
I
NEAR SOLIDS HANDLING BLDG 1,400 SF \\ BUILDING MAIN ELECTRICAL k
I
NEAR ODOR CONTROL 12,600 SF \ _ BUILDING
F. i STANDBY I
�\ / /----
POWER I
l,`
i\� GENERATOR
7---------\\
ON-SITE SIDEWALKS BUA
NEAR INFLUENT AREA 1,000 SF \
NEAR GRIT FACILITY 1,300 SF \ \ \\11 \a I II
ci I I
NEAR BLOWER BUILDING 1,500 SF •
\ \ -i'c'p I I
OI \ -\
NEAR CLARIFIERS 1-2 1,100 SF
, I
NEAR CLARIFIERS 4,5,AND 6 420 SF \ I
AROUND CHEMICAL FACILITY 1,200 SFo \
SITE PLAN I
w `\ NEAR SOLIDS HANDLING BLDG 1,800 SF \\\ I'-125' ' i 125 62.5 0 125' Z
z liTiTTiTI SCALE:1"=125'
g� U
--r PROJECT
ENGINEER: M.PARKER (....:,:\,„\
CARQiUNION COUNTY HDATE:,11
HAZENNO.: 30831-061 Za uDESIGNED BY: L.BENNETT s- LSS/oti9 1.� Hazen
NORTH CAROLINA OVERALL SITE PLAN o
M DRAWN BY: T.BARNES SEAL CONTRACT NO.: U
°'"' 26432 CIVIL D'
4^ CHECKED BY: J.STRUVE %, FWio/7.�.5 �5 HAZEN AND SAWYER TWELVE MILE CREEK WRF BUILT UPON AREA NUMBER:DRAWING o
IF THIS BAR DOES NOT 0 1/2" I" zoz. i17:5� -oaoo 9101 SOUTHERN PINE BOULEVARD ow
6< 1 REGULATORY/BUILDING CODE 7/2023 MDP MEASURE I"THEN DRAWING CHARLOTTE,NORTH CAROLINA 28273 9.0 MGD EXPANSION C6
po 7
LL 9 REV ISSUED FOR DATE BY IS NOT TO FULL SCALE ISSUED FOR CONSTRUCTION