Loading...
HomeMy WebLinkAboutWQ0000165_Compliance Evaluation Inspection_20230726DocuSign Envelope ID: 5AODEFBD-El20-404D-9602-68COE8DE11 FC Compliance Inspection Report Permit: WQ0000165 Effective: 05/01/21 Expiration: 06/30/27 Owner : Sands Villa Utilities Inc SOC: Effective: Expiration: Facility: Sands Villa WWTP County: Carteret 1400 E Fort Macon Rd Region: Wilmington Atlantic Beach NC 28512 Contact Person: Hope Mazzeo Title: Property Manager Phone: 252-247-0519 Directions to Facility: System Classifications: WW3., Primary ORC: Drew Boyd Piner Secondary ORC(s): On -Site Representative(s): On -site representative Related Permits: Certification: 1009727 Donald P Omara Phone: 252-726-1366 252-247-9167 Inspection Date: 07/26/2023 Entry Time 10:50AM Exit Time: 11:40AM Primary Inspector: Helen I Perez ° e�e Phone: 910-796-7387 AtZ� Secondary Inspector(s): 1 D645B4A39694BE... Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: High Rate Infiltration Facility Status: Compliant ❑ Not Compliant Question Areas: Treatment Flow Measurement -Effluent Treatment Flow Measurement -Influent Miscellaneous Questions Treatment Flow Measurement -Water Treatment Treatment Barscreen Use Records Treatment Filters Record Keeping Treatment Activated Sludge Treatment Influent Pump Station Treatment Disinfection End Use -Infiltration Treatment Flow Measurement Standby Power (See attachment summary) Page 1 of 7 DocuSign Envelope ID: 5AODEFBD-El20-404D-9602-68COE8DE11 FC Permit: WQ0000165 Owner - Facility: Sands Villa Utilities Inc Inspection Date: 07/26/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: A routine inspection of the Sands Villa WWTF was conducted on July 26, 2023. The purpose of the evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in Permit WQ0000165. Don O'Mara was present during the inspection. This facility is a 43,000 GPD, dual Sequencing Batch Reactor (SBR) system with two high -rate infiltration disposal fields. The flow averaged 7,647 GPD in May, and peaked at approximately 20,000 GPD on the July 4th weekend. A new SBR screen/program is now float activated and only operates when the wastewater reaches an optimal level for treatment. A review of records show that there has been no effluent violations since the last inspection in March 2021. The monitoring wells have had some TDS and Chloride exceedances, but likely attributable to background concentration of a barrier island environment. Since the start-up of the new BNR plant in 2008, nitrate exceedances have improved. The last exceedance waE in MW-6 in July 2022. The facility is compliant with Non -Discharge Permit WQ0000165. Please review the comment sections of the inspection report for more details. Page 2 of 7 DocuSign Envelope ID: 5AODEFBD-El20-404D-9602-68COE8DE11 FC Permit: WQ0000165 Owner - Facility: Sands Villa Utilities Inc Inspection Date: 07/26/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Lagoon Spray, LR ❑ Reuse (Quality) ❑ Single Family Spray, LR ❑ Activated Sludge Spray, LR ❑ Activated Sludge Spray, HR ❑ Activated Sludge Drip, LR ❑ Recycle/Reuse ❑ Single Family Drip ❑ Infiltration System Treatment Yes No NA NE Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑ Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑ Comment: No comment. Treatment Influent Pump Station Yes No NA NE Is the pump station free of bypass lines or structures? 0 ❑ ❑ ❑ Is the general housekeeping acceptable? ❑ ❑ ❑ Are all pumps present? ❑ ❑ ❑ Are all pumps operable? ❑ ❑ ❑ Are floats/controls operable? ❑ ❑ ❑ Are audio and visual alarms available? 0 ❑ ❑ ❑ Are audio and visual alarms operational? ❑ ❑ ❑ # Are SCADA/Telemetry alarms required? ❑ ❑ ❑ Are SCADA/Telemetry available? ❑ ❑ ❑ Are SCADA/Telemetry operational? ❑ ❑ ❑ Comment: The pumps have been recently replaced. Treatment Flow Measurement -Influent Yes No NA NE Is flowmeter calibrated annually? ❑ ❑ 0❑ Is flowmeter operating properly? ❑ ❑ ❑ Does flowmeter monitor continuously? ❑ ❑ ❑ Does flowmeter record flow? ❑ ❑ ❑ Does flowmeter appear to monitor accurately? ❑ ❑ ❑ Comment: Treatment Flow Measurement -Water Use Records Yes No NA NE Page 3 of 7 DocuSign Envelope ID: 5AODEFBD-El20-404D-9602-68COE8DE11 FC Permit: WQ0000165 Owner - Facility: Sands Villa Utilities Inc Inspection Date: 07/26/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine Is water use metered? Are the daily average values properly calculated? Comment: Treatment Flow Measurement -Effluent Is flowmeter calibrated annually? Is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Comment: The effluent flowmeter was calibrated in May by Delta Systems Environmental. Standby Power Is automatically activated standby power available? Is generator tested weekly by interrupting primary power source? Is generator operable? Does generator have adequate fuel? Comment: No comment. ❑❑■❑ ❑❑■❑ Yes No NA NE ■❑❑❑ ■❑❑❑ ■❑❑❑ Yes No NA NE Treatment Barscreen Yes No NA NE Is it free of excessive debris? ❑ ❑ ❑ Is disposal of screenings in compliance? ❑ ❑ ❑ Are the bars spaced properly? ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: Influent flows through the manually cleaned bar screen as it enters the EQ tank. The high-level alarm for the EQ tank was tested and found to be operable. Treatment Activated Sludge Yes No NA NE Is the aeration mechanism operable? 0 ❑ ❑ ❑ Is the aeration basin thoroughly mixed? 0 ❑ ❑ ❑ Is the aeration equipment easily accessed? ❑ ❑ ❑ Is Dissolved Oxygen adequate? ❑ ❑ ❑ Are Settleometer results acceptable? ❑ ❑ ❑ Is activated sludge an acceptable color? 0 ❑ ❑ ❑ Comment: From the EQ tank, influent flows through a splitter box to dual train SBRs. Process control testing consists of a settleometer test and a visual color nitrate test once a week, or more if needed. Micro-C is added as an additional carbon source. Solids are removed from the sludge holding tank by Barnes Environmental. Treatment Filters Is the filter media present? / ]r- ]..�.1N ■❑❑❑ Page 4 of 7 DocuSign Envelope ID: 5AODEFBD-El20-404D-9602-68COE8DE11 FC Permit: WQ0000165 Owner - Facility: Sands Villa Utilities Inc Inspection Date: 07/26/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine Is the filter media the correct size and type? 0 ❑ ❑ ❑ Is the air scour operational? ❑ ❑ 0 ❑ Is the scouring acceptable? ❑ ❑ 0 ❑ Is the clear well free of excessive solids? 0 ❑ ❑ ❑ Is the mud well free of excessive solids and filter media? ❑ ❑ 0 ❑ Does backwashing frequency appear adequate? ❑ ❑ 0 ❑ Comment: From the SBRs, wastewater flows to the post EQ, then to dual Pyradeck upflow filters which are manually cleaned as needed. Treatment Disinfection Yes No NA NE Is the system working? 0 ❑ ❑ ❑ Do the fecal coliform results indicate proper disinfection? ❑ ❑ ❑ Is there adequate detention time (>=30 minutes)? ❑ ❑ ❑ Is the system properly maintained? ❑ ❑ ❑ If gas, does the cylinder storage appear safe? ❑ ❑ ❑ Is the fan in the chlorine feed room and storage area operable? ❑ ❑ ❑ Is the chlorinator accessible? ❑ ❑ ❑ If tablets, are tablets present? ❑ ❑ ❑ Are the tablets the proper size and type? ❑ ❑ ❑ Is contact chamber free of sludge, solids, and growth? ❑ ❑ ❑ If UV, are extra UV bulbs available? ❑ ❑ ❑ If UV, is the UV intensity adequate? ❑ ❑ ❑ # Is it a dual feed system? ❑ ❑ ❑ Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? ❑ ❑ ❑ If yes, then is there a Risk Management Plan on site? ❑ ❑ ❑ If yes, then what is the EPA twelve digit ID Number? (1 000--_ If yes, then when was the RMP last updated? Comment: Disinfection consists of dual Trojan UV units. Record Keeping Yes No NA NE Is a copy of current permit available? ❑ ❑ ❑ Are monitoring reports present: NDMR? ❑ ❑ ❑ NDAR? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are application rates adhered to? ❑ ❑ ❑ Is GW monitoring being conducted, if required (GW-59s submitted)? ❑ ❑ ❑ Are all samples analyzed for all required parameters? ❑ ❑ ❑ Page 5 of 7 DocuSign Envelope ID: 5AODEFBD-El20-404D-9602-68COE8DE11 FC Permit: WQ0000165 Owner - Facility: Sands Villa Utilities Inc Inspection Date: 07/26/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine Are there any 2L GW quality violations? ❑ 0 ❑ ❑ Is GW-59A certification form completed for facility? ❑ ❑ ❑ Is effluent sampled for same parameters as GW? 0 ❑ ❑ ❑ Do effluent concentrations exceed GW standards? ❑ 0 ❑ ❑ Are annual soil reports available? ❑ ❑ 0 ❑ # Are PAN records required? ❑ ❑ 0 ❑ # Did last soil report indicate a need for lime? ❑ ❑ 0 ❑ If so, has it been applied? ❑ ❑ 0 ❑ Are operational logs present? 0 ❑ ❑ ❑ Are lab sheets available for review? ❑ ❑ ❑ Do lab sheets support data reported on NDMR? ❑ ❑ ❑ Do lab sheets support data reported on GW-59s? ❑ ❑ ❑ Are Operational and Maintenance records present? 0 ❑ ❑ ❑ Were Operational and Maintenance records complete? 0 ❑ ❑ ❑ Has permittee been free of public complaints in last 12 months? 0 ❑ ❑ ❑ Is a copy of the SOC readily available? ❑ ❑ 0 ❑ No treatment units bypassed since last inspection? 0 ❑ ❑ ❑ Comment: Operation and maintenance records were available for review and were found to be complete. A review of records show some Chloride and TDS exceedances in MWs #3, #4 and #6. Monitoring well #6 has had a history of Nitrate exceedances, but since the start of the new BNR plant in 2008, there's been much improvement. The last Nitrate exceedance was in July 2022. End Use -Infiltration Yes No NA NE # Is the application High Rate or Low Rate? High Rate Are buffers maintained? 0 ❑ ❑ ❑ Are any supply wells within the CB? ❑ ❑ ❑ Are any supply wells within 250' of the CB? ❑ ❑ ❑ Is municipal water available in the area? ❑ ❑ ❑ Are GW monitoring wells required? 0 ❑ ❑ ❑ Are GW monitoring wells located properly w/ respect to RB and CB? 0 ❑ ❑ ❑ Are GW monitoring wells properly constructed, including screened interval? ❑ ❑ ❑ Is a usable green area maintained? ❑ ❑ 0 ❑ Is the disposal site acceptable? 0 ❑ ❑ ❑ Is the distribution equipment acceptable? 0 ❑ ❑ ❑ Is the disposal site free of ponding? 0 ❑ ❑ ❑ Is the disposal site free of breakout? 0 ❑ ❑ ❑ Are the disposal sites free of solids, algae, etc.? 0 ❑ ❑ ❑ Page 6 of 7 DocuSign Envelope ID: 5AODEFBD-El20-404D-9602-68COE8DE11 FC Permit: WQ0000165 Owner - Facility: Sands Villa Utilities Inc Inspection Date: 07/26/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine Do the records show that the fields are properly maintained? 0 ❑ ❑ ❑ Are the disposal sites free of vegetation? ❑ 0 ❑ ❑ Do any surface water features appear to be adversely impacted by GW discharge? ❑ ❑ 0 ❑ No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.? 0 ❑ ❑ ❑ Comment: The 2 infiltration fields have some vegetation and has been allowed in the past. The effluent dosing tank high-level alarm was tested and found to be operable. Page 7 of 7