Loading...
HomeMy WebLinkAboutNC0045292_Graham_Mebane_WTP_CEI_Letter_20230718ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director City of Graham Attn: Frankie Maness P.O. Drawer 357 Graham, NC 27253-0357 NORTH CAROLINA Environmental Quality July 18, 2023 SUBJECT: Compliance Evaluation Inspection Graham/Mebane Water Treatment Plant NPDES Permit #: NCO045292 Alamance County Dear Mr. Maness: On June 5th, 2023, Division of Water Resources staff Ron Boone conducted a routine compliance evaluation inspection at Graham/Mebane Water Treatment Plant, wastewater discharge permit NCG0045292. ORC Shelby Smith was present during the inspection. A review of records, data, treatment components, structures, and the outfall was completed. This inspection reflected compliance with the subject permit. A review of all records such as laboratory data and reports, the permit, operator's logs, etc. were reviewed. The plant site was also inspected, including the lagoons themselves and the outfall to Back Creek. No violations, issues, or items of concern were noted during the inspection. Please be aware that pursuant to North Carolina general statute (NCGS) 143-215.6A, the Division may assess civil penalties not to exceed $25,000 per day against any person who fails to fully comply with the requirements of a permit issued pursuant to NC General Statute (NCGS) 143- 215.1., as is NC0088552. If you have any questions or concerns, please feel free to contact Mr. Boone at any time by phone at 336-776-9690, or by email at ron.boone@deq.nc.gov. Thank you for your time and attention to this matter. DffNorth Carolina Department of Environmental Quality I Division of Water Resources oan caaouNn Winston-Salem Regional Office 1 450 W. Hanes Mill Rd, Suite 300 I Winston-Salem, North Carolina 27105 M336.776.9800 oep.m.m or em�nmen� Qualm Sincerely, DocuSigned by: OD2D3CE3F1 B7456... Jennifer F. Graznak, Assistant Regional Supervisor Water Quality Regional Operations Section Winston-Salem Regional Office Division of Water Resources, NCDEQ Attachments: Water Compliance Inspection Report REQ� North Carolina Department ofEnvironmental Quality I Division ofWater Resources Winston-Salem Regional Office 1 450 W. Hanes Mill Rd, Suite 300 1 Winston-Salem, North Carolina 27105 NORTH CAROLINA 336.776.9800 naparMeM of EmironmanW 9uallly United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCO045292 111 121 23/06/05 I17 18 LC] I 19 I s I 20L] 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I ni I 71 I 74 79 I I I I I I I80 701 I 71 I LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 01:OOPM 23/06/05 17/07/01 Graham / Mebane WTP 1824 US Hwy 70 Exit Time/Date Permit Expiration Date Mebane NC 27302 02:OOPM 23/06/05 22/06/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Tonya Ane' Mann/ORC/336-578-3264/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Victor Ray Quick,PO Drawer 357 Graham NC 272530357H336-570-6700/3365135502 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran 0 Facility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Ron Boone Docusigned by: DWR/WSRO WQ/336-776-9690/ o"".& Boone, 7/17/2023 B20F8DD5F2A3460... Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date DWR/WSRo 336-776-9695 7/19/2023 F 6 Docusigned by: ev1��9� � Previous editions are obsolete. EPA Form 356-��W Page# NPDES yr/mo/day Inspection Type NCO045292 I11 12I 23/06/05 117 18 i c i (Cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On June 5th, 2023, Division of Water Resources staff Ron Boone conducted a routine compliance inspection at Graham/Mebane Water Treatment Plant, wastewater discharge permit NCG0045292. ORC Shelby Smith was present during the inspection. A review of records, data, treatment components, structures, and the outfall was completed. This inspection reflected compliance with the subject permit. A review of all records such as laboratory data and reports, the permit, operator's logs, etc, were reviewed. The plant site was inspected, including the lagoons themselves and the outfall to Back Creek. No violations, issues, or items of concern were noted during the inspection. Please feel free to contact Mr. Boone with any questions or concerns you may have. Page# Permit: NCO045292 Owner -Facility: Graham / Mebane WTP Inspection Date: 06/05/2023 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? 0 ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? 0 ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ❑ ❑ ❑ operator on each shift? Is the ORC visitation log available and current? ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility ❑ ❑ ❑ classification? Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑ Comment: None Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ■ ❑ ❑ ❑ application? Is the facility as described in the permit? ■ ❑ ❑ ❑ # Are there any special conditions for the permit? 0 ❑ ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: None Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? 0 ❑ ❑ ❑ Page# 3 Permit: NCO045292 Owner -Facility: Graham / Mebane WTP Inspection Date: 06/05/2023 Inspection Type: Compliance Evaluation Laboratory Yes No NA NE Are all other parameters(excluding field parameters) performed by a certified lab? 0 ❑ ❑ ❑ # Is the facility using a contract lab? ■ ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 0 ❑ ❑ ❑ degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ 0 ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ 0 ❑ Comment: None Lagoons Yes No NA NE Type of lagoons? Facultative # Number of lagoons in operation at time of visit? 2 Are lagoons operated in? Series # Is a re -circulation line present? ❑ 0 ❑ ❑ Is lagoon free of excessive floating materials? 0 ❑ ❑ ❑ # Are baffles between ponds or effluent baffles adjustable? ❑ ❑ ■ ❑ Are dike slopes clear of woody vegetation? ■ ❑ ❑ ❑ Are weeds controlled around the edge of the lagoon? 0 ❑ ❑ ❑ Are dikes free of seepage? 0 ❑ ❑ ❑ Are dikes free of erosion? 0 ❑ ❑ ❑ Are dikes free of burrowing animals? 0 ❑ ❑ ❑ # Has the sludge blanket in the lagoon (s) been measured periodically in multiple 0 ❑ ❑ ❑ locations? # If excessive algae is present, has barley straw been used to help control the growth? ❑ ❑ 0 ❑ Is the lagoon surface free of weeds? 0 ❑ ❑ ❑ Is the lagoon free of short circuiting? ■ ❑ ❑ ❑ Comment: None Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ❑ Comment: None Page# 4 Permit: NCO045292 Inspection Date: 06/05/2023 Owner -Facility: Graham / Mebane WTP Inspection Type: Compliance Evaluation Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: None Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable 0 ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: None De -chlorination Type of system ? Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de -chlorination substance stored away from chlorine containers? Are the tablets the proper size and type? Comment: None Are tablet de -chlorinators operational? Number of tubes in use? Comment: None Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Comment: None Yes No NA NE Liquid ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ EIN ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ■ ❑ ❑ ❑ Page# 5