HomeMy WebLinkAbout090065_Routine_202307260 Division of Water Resources
El Division of Soil and Water Conservation
El Other Agency
Facility Number: 090065 Facility Status: Active Permit: AWS090065 ❑ Denied Access
Inspection Type: Compliance Inspection
Reason for Visit: Routine
Date of Visit: 07/26/2023 Entry Time:
Farm Name: George Hall Nursery
Owner: George L Hall
Mailing Address: 148 Pine Crest Ln
Physical Address: 300 Lula Long Rd
Inactive Or Closed Date:
County: Bladen
09:15 am Exit Time: 3:00 pm
Facility Status: 0 Compliant ❑ Not Compliant
Region: Fayetteville
Incident #:
Owner Email:
Phone: 910-303-0301
Salemburg NC 283859059
Elizabethtown NC 28337
Integrator: Murphy -Brown LLC
Location of Farm: Latitude: 34' 44' 30" Longitude: 78' 36' 00"
From caution light in Garland, take US 701 S 2 blocks and turn rt onto SR 1200 W toward Bladen County. (SR 1200 changes to
SR 1528 in Bladen Co.) continue on SR 1528 to stop sign at NC 21 Intersection turn Rt onto NC 210 for 0.1 mile turn Lt. onto SR
Question Areas:
Dischrge & Stream Impacts Waste Col, Stor, & Treat Waste Application
Records and Documents 0 Other Issues
Certified Operator: George Linwood Hall
Secondary OIC(s):
Operator Certification Number: 997070
On -Site Representative(s): Name Title Phone
24 hour contact name Curtis Barwick
On -site representative Curtis Barwick
Primary Inspector:
Inspector Signature:
Secondary Inspector(s):
Katie Fontenot
Phone:
Date:
Inspection Summary:
7 Work on bare spots on lagoon to establist a vegetation.
25. you are over you sludge for two years. Sludge went out of compliance in 2019.
Page 1 of 5
Permit: AWS09006,' Owner: George L Hall Facility Number:090065
Inspection Date:07/26/23 Inspection TypeCompliance Inspection Reason for Visit:Routine
Regulated Operations
Swine
Design Capacity Current promotions
Swine - Wean to Feeder 2,600 I 2,600
Total Design Capacity: 2,600
Total SSLW: 78,000
Waste Structures
Effective Built Closed Designated Observed
Type Identifier Date Date Date Freeboard Freeboard
Lagoon
1
12/07/2005
I D8/04/1997
31.00
32.00
Lagoon
1-1
06/09/2005
D8/04/1997
19.50
Page 2 of 5
Permit: AWS090M Owner: George L Hall Facility Number:090065
Inspection Date:07/26/23 Inspection TypeCompliance Inspection Reason for Visit:Routine
Discharges & Stream Impacts
Yes
No NA NE
1. Is any discharge observed from any part of the operation?
❑
MEIEI
Discharge originated at:
Structure
❑
Application Field
❑
Other
❑
a. Was conveyance man-made?
❑
0 ❑
❑
b. Did discharge reach Waters of the State? (if yes, notify DWQ)
❑
0 ❑
❑
c. What is the estimated volume that reached waters of the State (gallons)?
d. Does discharge bypass the waste management system? (if yes, notify DWQ)
❑
0 ❑
❑
2. Is there evidence of a past discharge from any part of the operation?
❑
0 ❑
❑
3. Were there any observable adverse impacts or potential adverse impacts to Waters of the
❑
0 ❑
❑
State other than from a discharge?
Waste Collection, Storage & Treatment
Yes
No NA NE
4. Is storage capacity less than adequate?
❑
0 ❑
❑
If yes, is waste level into structural freeboard?
❑
5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ larc
❑
0 ❑
❑
trees, severe erosion, seepage, etc.)?
6. Are there structures on -site that are not properly addressed and/or managed through a
❑
MEI
❑
waste management or closure plan?
7. Do any of the structures need maintenance or improvement?
0
❑ ❑
❑
8. Do any of the structures lack adequate markers as required by the permit? (Not applicablE
❑
0 ❑
❑
to roofed pits, dry stacks and/or wet stacks)
9. Does any part of the waste management system other than the waste structures require
❑
❑
❑
maintenance or improvement?
Waste Application
Yes No NA NE
10. Are there any required buffers, setbacks, or compliance alternatives that need
❑ 0 ❑ ❑
maintenance or improvement?
11. Is there evidence of incorrect application?
❑ 0 ❑ ❑
If yes, check the appropriate box below.
Excessive Ponding?
❑
Hydraulic Overload?
❑
Frozen Ground?
❑
Heavy metals (Cu, Zn, etc)?
❑
PAN?
❑
Is PAN > 10%/10 lbs.?
❑
Total Phosphorus?
❑
Failure to incorporate manure/sludge into bare soil?
❑
Outside of acceptable crop window?
❑
Evidence of wind drift?
❑
Application outside of application area?
❑
Page 3 of 5
Permit: AWS09006� Owner: George L Hall Facility Number:090065
Inspection Date:07/26/23 Inspection TypeCompliance Inspection Reason for Visit:Routine
Waste Application Yes No NA NE
Crop Type 1 Coastal Bermuda Grass w/
Rye Overseed
Crop Type 2
Crop Type 3
Crop Type 4
Crop Type 5
Crop Type 6
Soil Type 1 Kenansville
Soil Type 2
Soil Type 3
Soil Type 4
Soil Type 5
Soil Type 6
14. Do the receiving crops differ from those designated in the Certified Animal Waste
❑
0 ❑
❑
Management Plan(CAWMP)?
15. Does the receiving crop and/or land application site need improvement?
❑
0 ❑
❑
16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre
❑
0 ❑
❑
determination?
17. Does the facility lack adequate acreage for land application?
❑
0 ❑
❑
18. Is there a lack of properly operating waste application equipment?
❑
0 ❑
❑
Records and Documents
Yes
No NA NE
19. Did the facility fail to have Certificate of Coverage and Permit readily available?
❑
0 ❑ ❑
20. Does the facility fail to have all components of the CAWMP readily available?
❑
0 ❑ ❑
If yes, check the appropriate box below.
WUP?
❑
Checklists?
❑
Design?
❑
Maps?
❑
Lease Agreements?
❑
Other?
❑
If Other, please specify
21. Does record keeping need improvement?
❑
0 ❑ ❑
If yes, check the appropriate box below.
Waste Application?
❑
Weekly Freeboard?
❑
Waste Analysis?
❑
Soil analysis?
❑
Waste Transfers?
❑
Weather code?
❑
Rainfall?
❑
Page 4 of 5
Permit: AWS09006� Owner: George L Hall Facility Number:090065
Inspection Date:07/26/23 Inspection TypeCompliance Inspection Reason for Visit:Routine
Records and Documents
Yes
No NA NE
Stocking?
❑
Crop yields?
❑
120 Minute inspections?
❑
Monthly and 1" Rainfall Inspections
❑
Sludge Survey
❑
22. Did the facility fail to install and maintain a rain gauge?
❑
❑
❑
23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipmen
❑
0 ❑
❑
(NPDES only)?
24. Did the facility fail to calibrate waste application equipment as required by the permit?
❑
0 ❑
❑
25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the
0
❑ ❑
❑
appropriate box(es) below:
Failure to complete annual sludge survey
❑
Failure to develop a POA for sludge levels
❑
Non -compliant sludge levels in any lagoon
List structure(s) and date of first survey indicating non-compliance: 69% Out of compliance
since 2019
26. Did the facility fail to provide documentation of an actively certified operator in charge?
❑
0 ❑
❑
27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification?
❑
0 ❑
❑
Other Issues
Yes
No NA NE
28. Did the facility fail to properly dispose of dead animals within 24 hours and/or document
❑
0 ❑
❑
and report mortality rates that exceed normal rates?
29. At the time of the inspection did the facility pose an odor or air quality concern? If yes,
❑
0 ❑
❑
contact a regional Air Quality representative immediately.
30. Did the facility fail to notify regional DWQ of emergency situations as required by Permit %
❑
0 ❑
❑
(i.e., discharge, freeboard problems, over -application)
31. Do subsurface tile drains exist at the facility?
❑
0 ❑
❑
If yes, check the appropriate box below.
Application Field
❑
Lagoon / Storage Pond
❑
Other
❑
If Other, please specify
32. Were any additional problems noted which cause non-compliance of the Permit or
❑
0 ❑
❑
CAW M P?
33. Did the Reviewer/Inspector fail to discuss review/inspection with on -site representative?
❑
0 ❑
❑
34. Does the facility require a follow-up visit by same agency?
❑
0 ❑
❑