Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCGNE1630_Application_20230725
Chalam Pakala Engineering and Environmental Solutions 10017 Allyson Park Dr.,Charlotte,NC 28277 Tel(704)756-7451,Fax: (704)5 1 VE D May 11,2023 JUL 25 2023 Ms.Brittany Cook,Permit Coordinator DEMLR•StOrmwater Progrs,;. NC DEMLR—Stormwater Permitting Unit 1612 Mail Service Center Raleigh,North Carolina 27699-1612 919 707 3641 office bethany georeoulias@.ncdenr.gov Re: NPDES Stormwater NO EXPOSURE Certification for Exclusion (NCGNEOOOO) Approval Request Braven Environmental, LLC 517 N. Industrial Dr. Zebulon, Wake County,North Carolina 27597 CPEES Prolect No. 1202-001 Dear Ms. Cook: Based on my discussions with Mr. Mike Lawyer,NC DEQ-NPDES Permit Supervisor,on behalf of Braven Environmental,LLC(Braven)located at 517 N. Industrial Dr.,Zebulon,North Carolina, CP Engineering and Environmental Solutions(CPEES)is pleased to submit the attached Stormwater NPDES No Exposure Certification for Exclusion(NCGNE0000)request for the subject facility operations. The facility manufactures liquid petrochemicals using waste plastics via pyrolysis method and the generated products are stored on site in an aboveground storage tanks contained in a concrete dike. The operations are conducted under SIC/NAICS Code 2869/32511"Petrochemical Manufacturing". Based on my conversations with Mr. Mike Lawyer, I understand that if the petroleum tanks are contained in a dike and no other industrial activity is exposed to rain water, the facility could apply for a No Exposure Citification for stormwater discharges at the subject facility. In addition, we had installed an Oil/Water Separator to remove oils below the State standards using oil coalescing screens. We intend to discharge the dike stormwater through the proposed oil/water separator from the facility to the outfall as deemed necessary. All collected oils from the oil/water separator will be either recycled in the plant or disposed of properly using a licensed disposal contractor. The outfall location with lat/long is provided on the Site Drainage Map. The Stormwater NPDES No Exposure Certification for Exclusion(NCGNE0000)Application package includes: • A signed NC DELMR supplied NCGNE0000 NOI application; • Process Flow Diagrams and proposed Oil/Water Separator installation details: • USGS TOPO Map; • Site Drainage Map showing the proposed Oil/Water Separator location; • Site Drainage Map showing the location of the outfall from the facility; and • TMDL and 303(d)Maps. Chalam Pakala Engineering and Environmental Solutions 10017 Allyson Park Dr.,Charlotte,NC 28277 Tel(704)756-7451,Fax:(704)541-4042 Please call me at 704-756-7451 or Mr. Chris Serrati at 501-628-4793 or Alex Gonzalez at 305-710-4539 should you have any questions on this permit application request. Respectfully submitted, \`+t 11 l llll�' CP Engineering and Environmental Solutions � CARO /i,� (A Cost Effective Solution Provider for Manufacturing) �OQ •FES8/,.. �2tO y•,� SEAL ' 19807 . P.E. Ali l Managing PrincipalqM p O5/11/2023 Attachment:No Exposure Certification for Exclusion(NCGNE0000)Application Package NPDES STORMWATER "NO EXPOSURE CERTIFICATION FOR EXCLUSION" (NCGNE0000)NOI FORMS FOR AGENCY USE ONLY NCGNE l� 3 0 Assigned to: 0. G ARO FRO MRO nWARO WIRO WSRO Division of Energy, Mineral, and Land Resources National Pollutant Discharge Elimination System No Exposure Certification for Exclusion NCGNE0000 Submission of this No Exposure Certification constitutes notification that your facility does not require a permit for stormwater discharges associated with industrial activity in the State of North Carolina because it qualifies for a no exposure exclusion.A condition of no exposure at an industrial facility means all industrial materials and activities are protected by a storm resistant shelter (with some exceptions) to prevent exposure to rain, snow, snowmelt, and/or runoff. Industrial materials or activities include, but are not limited to: • material handling equipment or activities, • by-products, • industrial machinery, • final products, or • raw materials, • waste products. • intermediate products, Material handling activities include the storage, loading and unloading, transportation, or conveyance of any raw material, intermediate product,final product, or waste product. A storm resistant shelter is not required for industrial materials stored in the following container types, provided the containers are not deteriorated and do not leak: • drums, • tanks,and • barrels, • similar containers. For new facilities, applicants should apply no earlier than 60 days before the start of operation. This will allow DEMUR staff to verify conditions during active operation. For facilities that already have an industrial stormwater permit in North Carolina, DEMLR must approve your application for No Exposure Certification before this exclusion is effective. Until you are issued a No Exposure Certification and your NPDES permit is rescinded,your facility must continue to abide by the terms and conditions of the current permit. A No Exposure Certification must be provided for each facility qualifying for the no exposure exclusion.Additionally, the exclusion from NPDES permitting is available on a facility-wide basis only — not for individual outfalls. If any industrial activities or materials are,or will be,exposed to precipitation,the facility is not eligible forthe no exposure exclusion. By signing and submitting this No Exposure Certification form,you certify that a condition of no exposure exists at this facility or site and are obligated to comply with the terms and conditions of 40 CFR 122.26(g). For new facilities, applicants should not apply more than 60 days before the start of operation date. This If approved, your conditional No Exposure Certification has no expiration date but must be self-recertified at least annually. Please look for information about recertification under the No Exposure section on this page: https://deg nc gov/about/divisions/`energy-mineral-land-resources/npdes-no-exposure. Directions: Print or type all entries on this application form. Send the original, signed application to: NCDEMLR Stormwater Program, 1612 MSC, Raleigh, NC 27699-1612. The submission of this form does not guarantee exclusion from NPDES stormwater permitting. Prior to exclusion from NPDES stormwater permitting a site inspection will be conducted. Page 1 of 6 1. Owner/Operator(to whom all permit correspondence will be mailed): Name of legal organizational entity: Legally responsible person(as signed in Item 7 below): BRAVEN ENVIRONMENTAL, LLC MR. CHRIS SERRATI Street address: City: State Zip Code 517 N. INDUSTRIAL DR. ZEBULON NC 27591 Telephone number: Email address: 501-6284793 Type of Ownership: Government ❑ County ❑ Federal ❑ Municipal ❑ State Non-government 8 Business(if ownership is business,a copy of NCSOS report must be included with this application) ❑ Individual 2. Industrial Facility (facility requesting exclusion): Facility name: Facility environmental contact: BRAVEN ENVIRONMENTAL, LLC MR. CHRISTOPHER R. SERRATI Street address: Telephone number: 517 N. INDUSTRIAL DR. 501-628-4793 Email address: cserrab@bravenenvironmental.com City County State Zip Code ZEBULON WAKE North Carolina 27591 anig;udeofetnLance,35°49'40.99" N,78018'22.94" W Parcel Identification Number(PIN): 2705574023 Date operation began: Standard Industrial Classification(SIC)Code: 2019 Brief description of the types of industrial activities and products produced at this facility: PYROLYSIS OF WASTE PLASTICS 3. Consultant(if applicable): Name of consultant: Consulting firm: CHALAM PAKALA CP ENGINEERING&ENVIRONMENTAL SOLUTIONS Street address: City: State and zip code: 10017 ALLYSON PARK DR. CHARLOTTE NC, 28277 Telephone number: Email address: 704-756-7451 1 CVPAKALA@CAROLINA.RR.COM 4. Exposure Checklists Are any of the following materials or activities exposed to precipitation, now or in the foreseeable future? If you answer"Yes"to any of these items,you are not eligible for the no exposure exclusion. Using,storing,or cleaning industrial machinery or equipment,and areas where residuals from using,storing,or cleaning industrial machinery or equipment remain and are exposed to ❑ Yes R No ❑ N/A stormwater Materials or residuals on the ground or in stormwater inlets from spills/leaks ❑ Yes ® No ❑ N/A Materials or products from past industrial activity ❑ Yes ❑ No W N/A Material handling equipment(except adequately maintained vehicles) ❑Yes ❑ No 9 N/A Page 3 of 6 Materials or products during loading/unloading or transporting activities ❑Yes 9 No ❑ N/A Materials or products stored outdoors(except final products intended for outside use[e.g.,new ❑Yes 9 No ❑ N/A cars)where exposure to stormwater does not result in the discharge of pollutants) Materials contained in open,deteriorated, non-sealed',or leaking storage drums barrels,tanks, ❑Yes 9 No ❑ N/A and similar containers Materials or products handled/stored on roads or railways owned or maintained by the discharger ❑Yes 9 No ❑ N/A Final products that would be mobilized in stormwater discharges(e.g.,rock salt) ❑Yes 9 No ❑ N/A Waste material(except waste in covered,non-leaking containers(e.g.,dumpsters]) ❑ Yes 9 No ❑ N/A Application or disposal of process wastewater(unless otherwise permitted) ❑Yes 9 No ❑ N/A Particulate matter or visible deposits of residuals from roof stacks and/or vents not otherwise ❑Yes 9 No ❑ N/A regulated(i.e.under an air quality control permit)and evident in the stormwater outflow Empty containers that previously contained materials that are not properly stored(i.e.,not closed ❑Yes 9 No ❑ N/A and stored upside down to prevent precipitation accumulation) For any exterior ASTs,as well as drums,barrels,tanks and similar containers stored outside,has ❑Yes 9 No ❑ N/A the facility had any releases in the past three(3)years? 'Sealed means banded or otherwise secured and with locked or non-operational taps or valves. Above Ground Storage Tanks(ASTs)and Secondary Containment If you answer"No"to any of the following items,you are not eligible for the no exposure exclusion. Are exterior ASTs or piping free of rust,damaged or weathered coating,pits,or deterioration,or g Yes❑No ❑ N/A evidence of leaks? Is secondary containment provided for all exterior ASTs?If so,is it free of any cracks,holes,or 9 Yes❑ No ❑ N/A evidence of leaks,and are drain valves maintained locked shut? Is secondary containment provided for single above ground storage containers(including drums, g Yes❑ No ❑ N/A barrels,etc.)with a capacity of more than 660-gallons? Is secondary containment provided for above ground storage containers stored in close proximity 9 Yes❑ No ❑ N/A to each other with a combined capacity of more than 1,320 gallons? Is secondary containment provided for Title III Section 313 Superfund Amendments and Reauthorization Act(SARA)water priority chemicals? ®Yes❑ No ❑ N/A Is secondary containment provided for hazardous substances designated in 40 CFR 4116? 9 Yes❑ No ❑ N/A Are release valves on all secondary containment structures locked? ®Yes❑No ❑ N/A Other information If you answer"Yes"to any of the following items,you might not be eligible for the no exposure exclusion.A more in-depth evaluation of the site circumstances may be required. Are vehicles used in material handling in disrepair and/or leaking fluid? ❑ Yes 9 No ❑ N/A Does this facility store used,recycled,or otherwise reclaimed pallets outside? ❑Yes 9 No ❑ N/A Does this facility have coal piles on site? ❑Yes 9 No ❑ N/A Does this facility store other fuel sources outside in piles,such as wood chips,sawdust,etc.? ❑Yes 9 No ❑ N/A Page 4 of 6 Does this facility have air emissions associated with industrial activity(e.g.,degreasing operations, l3 Yes ❑ No ❑ N/A plating, painting,or metal finishing)? If yes: PYROLYSIS OF WASTE PLASTICS Describe the industrial activity: Are those emissions permitted by an Air Quality Permit? 8 Yes ❑ No Please specify: AIR PERMIT NO. 10672R00, ISSUE DATE 9125/2020,EXP DATE 8/31/2028 S. Other Facility Conditions (check all that apply and explain accordingly): ❑This facility has other NPDES permits. If checked,list the permit numbers for all current NPDES permits: A 1 /t El This facility has Non-Discharge permits(e.g. recycle permit). I V/1 If checked, list the permit numbers for all current Non-Discharge permits: NA ❑This facility stores hazardous waste in the 100-year floodplain. If checked,describe how the area is protected from flooding: A I A ❑This facility is a (mark all that apply) V/1 W Hazardous Waste Generation Facility ❑ Hazardous Waste Treatment Facility ❑ Hazardous Waste Storage Facility ❑ Hazardous Waste Disposal Facility If checked, indicate: >1000 KGS/MONTH • Kilograms of waste generated each month: • Type(s)of waste: BENZENE CONTAINING MATERIALS • How material is stored: DRUMS/TOTES INSIDE THE BLDG • Where material is stored: • Number of waste shipments per year: ONCE OR TWICE-STILL ANEW PROCESS • Name of transport/disposal vendor: Southern Logistics&Environmental, LLC • Transport/disposal vendor EPA ID: NCR000163832 • Vendor address: 2710 PATTERSON ST.GREENSBORO, NC 27407 ❑This facility is located on a Brownfield or SUPERFUND site. If checked, briefly describe the site conditions: A 1 A El This facility is located on Native American Lands.NA V/1 6. Required Items(Application will be returned unless all of the following items have been included): ® Copy of most recent Annual Report to the NC Secretary of State(if applicable) B This completed application and any supporting documentation 8 Copy of county map or USGS quad sheet with the location of the facility clearly marked Page 5 of 6 7. Applicant Certification North Carolina General Statute 143-215.613(i)provides that: Any person who knowingly makes any false statement, representation,or certification in any application, record, report,plan,or other document filed or required to be maintained under this Article or a rule implementing this Article.. .shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars($10,000). 1 hereby request exclusion from NPDES stormwater permitting. Under penalty of law, I certify that: X I am the person responsible for the industrial activity,for satisfying the requirements of this exclusion,and for any civil or criminal penalties incurred due to violations of this exclusion. X I have read and understand the eligibility requirements for claiming a condition of"no exposure"and obtaining an exclusion from NPDES stormwater permitting. X There are no discharges of stormwater contaminated by exposure to industrial activities or materials from the industrial facility or site identified in this document(except as allowed under 40 CFR 122.26(g)(2)). X I understand that I am obligated to maintain no exposure conditions and complete a Self-Recertification form at least once each year and,if requested,provide this certification to the operator of the local municipal separate storm sewer system(MS4)into which the facility discharges(where applicable). I understand that I must allow the North Carolina Division of Energy,Mineral,and Land Resources,or MS4 operator where applicable,to perform inspections to confirm the condition of no exposure and to make such inspection reports publicly available upon request. I understand I must keep a copy of annual recertifications on file at the facility. X I understand that in the event that the site no longer qualifies for a No Exposure Exclusion that I must obtain coverage under an NPDES permit prior to any point source discharge of stormwater from the facility. X The information submitted in this NOI is,to the best of my knowledge and belief,true,accurate,and complete based on my inquiry of the person or persons who manage the system,or those persons directly responsible for gathering the information. Printed Name of Person Signing: PLANT MANAGER Title: i 7 J UL 23 Signature of Applicant Date Signed Mail the entire package to: DEMLR—Stormwater Program Department of Environmental Quality 1612 Mail Service Center Raleigh, INC 27699-1612 Page 6 of 6 FIGURES Figure— I Site USGS TOPO Map Figure—2 Site Drainage Maps .e • 111 ', `,��11���I� L��\\Il���_�.Lil�� ,e 01►11�Isi^r,� — — ��,�� �.. '. a •. �� e� 1�1.7�J\� — a 111 LmopH EMU 109 OIL _w 0% . l W- i SITE LOCATION MAP BRAVEN ENVIRONMENTAL, LLC. FIGURE 1 JOB NO. 1 11 PROPERTY LINE FF- � I I ISCRAP STEEL I I 3,000 GALLON OIL/WATER SEPARATOR ON A PAD IN A I ISECONDARY CONTAINMENT DIKE I10,000 GALLON WASTE PLASTICS, I ILIGHT CUT PYROLYSIS OIL(T-103) I I ! 10,000 GALLON MEDIUM CUT PYROLYSIS OIL(T-102) i I I 3,000 GALLON HEAVY CUT I PYROLYSIS OIL(T-100) I10,000 GALLON MIXED CUT PYROLYSIS OIL(T-101) SPILL CONTAINMENT AREA Z I I (36,170 GALS) e — NC Surface Water Classifications NC�Cla�fi no s iWtsiw RP�n r I]N'ntlusfial Dr__ X Q as pp OV © roowe„nor y, - Surface Water Classifications: Stream Index 27-8644 Stream Name: Little Creek(Weet Side) Description: From source to Moccasin Creek s I Classification: C;NSW >Sy s� t ,yTs q Ncas sd iw 8 - Date of Class.: April 30,1988 O What does this Class.mean? View River Basin: Neuse > s ' i E19sw 64 4 ' e 4 b Zeulon "� 1 X iw aS�b. � pew i Port y 6� uY .y zv - uo B9k ty:M1 Z ,�. ��- e' WI WAN s i � ui NC TMDL and TMDL Alternative Watersheds Mat.Type River bmip Peumeters lmuhlple axle.. . 7,10E en = Project List . . GH 0 51)N.iMamiN Dr.Zebe X Q * 5 Major Rher aaaim Nepx River Ertuary TMDL - 5B nendL ft-a a cried { I— ____. OunilM _ __ _ __ �_—__..__ ... ., e� ` —.___ WOL and Alterna6ve Plan � Fed. � �T.N. w en ine 'a— G...n.bma .. ''�9.1 'abinz .-.NOU Hi M1PaM Ourly Lwwr RWY Mean j ' e - S(IMOIE.Mree! aaaa Nn Xi[korY Suur.ill. a R y1r O t SNrbuO rnaGom } ./ '.Ywr..alu Srrfaetl Click LTM for information on the Statewide Mercury TMDL Spe.aRR 'i aodimF.m _ Project Details \ atloe ar.�rr..a L flx.R. Mlm�neron Select.prcjwt Gam do fin.bon 1,. „^"� _ Colunbla l• �,ni MM•axdr. un.aNu:.et..nrp Sa -.,.M.Ge—FaO, mC,.Ertrt a.Q. wv.maF.�n PROCESS FLOW DIAGRAMS AND OIL/WATER SEPARATOR INSTALLATION DETAILS Zebulon Wastewater System Process Flow Diagram ( Max. Capacity Operation ) Tank 100 Tank 101 Sump Flow 300 gpm Oil Water Treated Storm Water Containment Pump#1 Separator Wastewater Sewer Area (100 gpm) Process Equipment Containment Area Tote Recovered (275 gal.) Oil Tank 102 F(Pu Tank 103 #2 Containment m) iSolids Area ading Sump tainment Pump#3 Area (50 gpm) (Future) (Future) GRAVEN ENVIRONMENTAL, LLC CONFIDENTIAL 1 Zebulon Containment Areas vice w/Pio IY-Y . � Fractionation w Truck Loading Containment Area eoo Containment Are e� I ,a• � �P �) �j� e• � ,�a mP u¢ Y r-P _ r-e• 1 I I eOawT Y-a• a'-�• e'-o• I I ,noun-'1 in a°eaim m004,eP -Ce(p�-°1� -om-ool Sum /Pump _d mp!Pump m. c,aorc Tank 100& 101 a°°" Tank 102 & 103 M. .. o o u ovoP Containment Area Containment Area �-�•o-,n T 0 •__• _ f.M. PLAN AT GRADE NOT TO SO/LE BRAVEN ENVIRONMENTAL, LLC CONFIDENTIAL 3 Zebulon Facility with Oil Water Separator RIOI ..p Fractionation Truck Loading Containment Area Containment Are oilyisw 8y SeDerawr I Ir-r �4 Y4i Comakmrent mu o rw• r-r _ r Ir-rne ua y. !-rRl% 0.101 IM' I .B901M: Y-f ' Y-f r-r I I 1 _ 41.E _ FIW1 RIOY - r Y T Y-f Ti-�tq i-,W 1 M-ql OOY fM IOIYfG uw m®'r m°°ris -m, Sum /Pump r; mP%Pump 00 Tole Tank 100& 101 Tank 102& 103 Containment Are Cont tnmentAre owwawr Saps abr To-lm � '-' rv. PLAN AT GRADE MOT TO S NE BRAVEN ENVIRONMENTAL, LLC CONFIDENTIAL 4 Zebulon Facility with Oil Water Separator ( Detail view ) Truck Loading Containment Are br-o- w-r T +, a Oil Water e = Separator Contaimtient lar�'la top am a. e emi. Doer a r II �. _7. _a. 1,-p, nc-,oi nt-root - - IK_102 IX-103 I I 1 r-loos i4 Sum Pump '' ° mpPump =L ©tl Tole Tank 100 & 101 Tank 102 & 103 Containment Are Containment Area Oil Water Separator I � © I GRAVEN ENVIRONMENTAL, LLC CONFIDENTIAL 5 OIL WATER SEPARATOR 5� TECHNOLOGIES, LLC TECH 1109 25th STREET, STE. E & F WEST PALM BEACH, FL 33407 1-800-770-0099 WWW.OWSTECH.COM OWS-TECH STANDARD MODEL # O WS-SA-H F-SS-300 ENVIRO VAC OWSTECH JOB# 18005 INSTALLATION, OPERATION, AND MAINTENANCE BROCHURE OWS TECH 1109 25TH Street,Ste. E& F West Palm Beach, FI 33407 TABLE OF CONTENTS Installation, Operation, Maintenance OWS-STD Oil Water Separator Specification OWS-STD OWS Model (SA-HF-SS-300) Drawing#4S5236 Anchor Bolt Location Drawing#3S5218 6" 0 Rotary Pipe Skimmer Drawing#3S5129 Coalescing Filters (Tube Arrangement) Drawing#1S5013 OWS TECH 1109 25`h STREET WEST PALM BEACH, FL 33407 Installation, Operation and Maintenance Instructions for above grade models (SA-HF-SS-300) Installation: 1. Locate separator at desired location using the supplied lifting lugs. 2. Inlet Pipe-Attach to waste water source. 3. Outlet Pipe-Attach to discharge. 4. Oil Outlet Pipe-Attach to oil storage tank or install shut-off valves. 5. Drains- Install shut-off valves and/or pipe back to sump pit. 6. Install anchors using the supplied anchor bolt location drawing. Operation: 1. Fill unit with clean water. 2. Introduce waste water stream at or below the separators rated flow rate per minute. 3. Rotate oil skimmer to a vertical position. 4. Oil will accumulate at the surface. 5. Clean water will pass thru the unit to the discharge pipe. 6. Solids will fall to the bottom of the inlet chamber as well as under the coalescers in the - ---separation-chamber. — — Maintenance: 1. Remove oil layer by rotating skimmer pipe open area towards oil. Remove excess oil only to avoid removing clean water. Minimum oil level build up prior removal %_" or approximately 15 gallons. Maximum oil level build up before affecting the separation process is 4 inches or approximately 120 gallons. 2. Check for solids build up. A. Rotate vertical fiberglass angles upward to remove front horizontal hold down angle. B. Remove front horizontal hold down angle. C. Remove center bundle from the first row and check to see if there are solids in the bottom portion of the bundle. D. If solids are present it is time to remove the coalescers and clean. E. Remove grating and the solids from the bottom of the separator. F. Reinstall grating, coalescers and hold down angle. G. Fill unit with clean water. Unit is now ready for operation. OWS TECH 1109 25 h STREET WEST PALM BEACH, FL 33407 SQUARE ABOVE HIGH FLOW (SA-HF) SERIES SPECFICATION Model Number(SA-HF-SS-300) Design Parameters: Installation Above Ground Flow Rate 0-300 GPM Oil Removal 20 Micron Size and larger down to 10 ppm Oil Storage Capacity 120 Gallons Oil Spill Capacity 810 Gallons Sludge Capacity 36 Cu/Ft. Operating Capacity 2,450 Gallons Empty Weight Estimated 6,111 LBS. - --- Operating-Weight-Estimated 26,5.20 LBS. _ Operating Temperature 33—130 degrees Materials of Construction: Tank, baffles, lid, nozzles, fitting, Hardware, and identification tag Stainless Steel 304 L High Efficiency Coalescers (HEC) Packs Polypropylene Rotary Pipe Skimmer (FRP) Rotary Pipe Skimmer Mounting Bracket (FRP) Grating (FRP) OWS TECH 1109 251^STREET WEST PALM BEACH, FL 33407 Nozzles: Inlet One (1)4"0 Flanged Outlet One (1) 8"0 Flanged Oil Outlet One (1) 6"0 Flanged Level Switch One (1) 2"0 Flanged Drains/Solids Three (3) 2" 0 Flanged Vent One (1) 2"0 Flanged Separator Internals/Chambers: Inlet Diffuser Evenly distributes flow Inlet Chamber Collects solids Inlet Baffle Directs flow thru (HEC) Pack Separation Chamber Removes 20 micron size and larger oil droplets using 114 Cubic ft. or 5,244 Sq. Ft. of-High-Efficiency Coalescers-(HEC) pack.- - - Sludge/Solids Chamber Allows solids to collect below the High Efficiency Coalescers (HEC) Pack for easy solids removal. Oil Retention Baffle Retains floating oil for removal utilizing the rotary pipe skimmer. Weir Wall Maintains a constant water level in the separation chamber. Outlet Chamber Clear well complete with 8" 0 Tee Pipe to allow only the cleanest water to exit the Separator. O WS TECH 1109 251h STREET WEST PALM BEACH, FL 33407 Separator Access: Manways One (1) 5'-3"x 4'-0" One (1)4'-0"x 2'-0" 77 B 99 11 ' - 6" 7, -41„ I I I I 12 I I I I I I I I -- - - - - - - - - - - - - I I � I I 5 it I . I I OO I 4A 4A I I I I 77 � 77 I I I I 3' - 04 I I I I I a I I i I i i i SHELL REF. i Wes-.ivy m � cn O O O p O O Oco O O -F11 O � XVIVX O O O � 0 � � 0 O O O m o _ o - XVIVX z m 0 W P F_ 0 O O O coo < z O O _ ! _ O O O O O O 0 O O O fV k7 O O N :� O i 0 O 0 0 'DE, OWSSA—HF—SS1300 TUBE ARRANGEMENT JOB ®A OIL WATER SEPARATOR ID: DRAWING No. TN6 DRAWGiG MID SPECIFIGTION IS D w; TM TECHNOLOGIES LLC gre'P N.T.S. TE PROPEM OF OWS TECNNOMES ENVIRO VAC 1 S5013 1109 25 �``'16f PP11�. TECH D+E 12/10/13 ti 3 o AND SHALL NOT BE FM'1ems-TA 1/n11e 10 09 25TH STREET W.P.B., FL. 33407 REPRwD°m WRNDw"""'E" CNEa®W. PpVML410N.