Loading...
HomeMy WebLinkAboutNC0088927_Fact Sheet_20230713 Fact Sheet for New Permit Jun 2023 - NPDES Permit NC0088927 - Page 1 NCDEQ / DWR / NPDES EXPEDITED FACT SHEET – NPDES PERMIT RENEWAL NPDES Permit NC0088927 / NCG590042 Sydney Deuterman / Compliance & Expedited Permitting Unit / sydney.deuterman@deq.nc.gov / June 2023 Facility Information Facility Name Meadow Ridge Subdivision Water Treatment Plant Applicant Name/Contact Aqua North Carolina, Inc. / Amanda Berger, Director of Environmental Compliance AABerger@aquaamerica.com Applicant Address 202 Mackenan Court, Cary, NC 27511 Facility Address 7626 Anthony Road, Stokesdale, NC Max, Monthly Avg Flow (MGD) 0.00334 MGD Type of Waste Filter backwash from greensand WTP Facility Class PC-1 County Guilford Permit Status Renewal Regional Office WSRO Stream Characteristics Receiving Stream UT to Kings Creek Stream Classification B Stream Segment 22-27-8-3 Outfall Lat. 36° 12' 40" N Summer 7Q10 (cfs) 0 Outfall Long. 80° 00' 15.8" W Winter 7Q10 (cfs) 0 Drainage basin Roanoke 30Q2 (cfs) 0 Subbasin 03-02-01 Average Flow (cfs) 0 303(d) Listed Not Impaired IWC (%) 100% HUC 030101030303 FACILITY SUMMARY Meadow Ridge Subdivision WTP is a greensand water treatment plant with a design capacity of 0.072 MGD using groundwater wells. The treatment process for the raw water consists of chlorination, four greensand filters and the addition of caustic for pH control. Backwash water from the filters is dechlorinated and then intermittently discharged into a UT which flows into a local pond that then feeds into Kings Creek. The existing treatment components at the water treatment plant are the following: • Four (4) greensand filters • Chlorination • Dechlorination Chemical usage consists of: • Caustic soda (pH control) • Calcium thiosulfate (dechlorination) RENEWAL SUMMARY The facility has requested to transfer coverage to the NCG590000 General Permit. Based on the general permit’s requirements, they are eligible for coverage and will be switching over. The new permit number is NCG590042. The individual permit will be rescinded. NCG59 GENERAL PERMIT ELIGIBILITY (FOR CONVENTIONAL & GREENSAND WTPS): • This facility does not perform toxicity testing – eligible • No metal limits in the existing permit – eligible • Conclusion: Eligible for NCG59 General Permit. Fact Sheet for New Permit Jun 2023 - NPDES Permit NC0088927 - Page 2 COMPLIANCE HISTORY Meadow Ridge Subdivision WTP has no enforcements on record since the permit was originally issued in 2010. The most recent inspection (May 2018) showed the facility to be in compliance and very well maintained. Only one NOD was issued during the last permit cycle. REASONABLE POTENTIAL ANALYSIS A reasonable potential analysis (RPA) was not performed as this facility does not monitor for any of the specific pollutants.