HomeMy WebLinkAboutOnslow_Well Abandonment_20230724 (2) WELL ABANDONMENT RECORD For Internal Use ONLY:
I �
1.Well Contractor Information: WELL ABANDONMENT DETAILS
Scott M. Werle
Y 7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same
Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only I GW-3'0 is needed. Indicate TOTAL NUMBER of
3344—A wells abandoned:o^e m
NC Well Contractor Certification Number 7b.Approximate volume of water remaining in well(s): 1 .75 (gal.)
ECS Southeast, LLP FOR WATER SUPPLY WELLS ONLY:
Company Name 7c.Type of disinfectant used:
2.Well Construction Permit#: WM0801202
List all applicable hell construction permits(i.e.UIC,County,Stale,Variance,etc.)ifknown
7d.Amount of disinfectant used:
3.Well use(check well use):
Water Supply Well: 7e.Sealing materials used(check all that apply):
❑Agricultural ❑Municipal/Public a Neat Cement Grout a Bentonite Chips or Pellets
❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑ Dry Clay
❑Industrial/Commercial ❑Residential Water Supply(shared) ❑ Concrete Grout ❑Drill Cuttings
❑lrri ation ❑ Specialty Grout ❑Gravel
Non-Water Supply Well: ❑ Bentonite Slurry ❑Other(explain under 7g)
IlMonitoring ❑Recovery
Injection Well: 7E For each material selected above,provide amount of materials used:
❑Aquifer Recharge ❑GroundwaterRemediation Bentonite —15 Ibs
❑Aquifer Storage and Recovery ❑Salinity Barrier
❑Aquifer Test ❑StormwaterDrainage Neat cement—25Ibs
❑Experimental Technology ❑Subsidence Control
7g.Provide a brief description of the abandonment procedure:
❑Geothermal(Closed Loop) ❑Tracer Bentonite - gravity feed from 15 to 5' bgs
❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g)
Neat cement- pour from 5' bgs to surface
4.Date well(s)abandoned: 7/6/2023 � ,�„�
r"s pr%r,R�Bp '1
d
Sa.Well location: r y— r 8
Prop Wawa Jacksonville N/A JUL r _ 2023
Facility/Owner Name Facility ID#(ifapplicable) 8.Certification: `\ t ornC,°JS{J:°+��it`I
1113 Western Blvd., Jacksonville, 28546 '�'
��(U / rx�,`w 7/7/2023
Physical Address,City,and Zip Signature of Certified Well Contractor or yell Owner Date
Onslow 049903
By signing this form, I hereby certify that the ivell(s) was (were) abandoned in
County Parcel Identification No.(PIN) accordance with 15A NCAC 02C.0100 or 2C.0200 Well Constniction Standards
Sb.Latitude and longitude in degrees/minutes/seconds or decimal degrees: and that a copy of this record has beefprovided to the well owner.
(ifwell field,one IaUlong is sufficient) 9.Site diagram or additional well details:
34.779904 N 77.396206 W You may use the back of this page to provide additional well site details or well
abandonment details. You may also attach additional pages if necessary.
CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS
Attachirellconsirttctionrecord(.v)ifm,ailnbte. Forntttltipleinjectiwtornon-waterstupplyirells
ONLY with the some constructiotrabaudwtmeni,you can submit one form.
MW03 10a. For All Wells: Submit this form within 30 days of completion of well
6a.Well ID#: abandonment to the following:
Division of Water Resources,Information Processing Unit,
6b.Total well depth: 15 —(ft.) 1617 Mail Service Center,Raleigh,NC 27699-1617
IOb. For Infection Wells: In addition to sending the form to the address in 10a
6c.Borehole diameter: 6 (in) above, also submit one copy of this form within 30 days of completion of well
abandonment to the following:
6d.Water level below ground surface• 4.37 M) Division of Water Resources,Underground Injection Control Program,
1636 Mail Service Center,Raleigh,NC 27699-1636
6e.Outer casing length(if known):
5 1Oc.For Water Supply&Infection Wells: In addition to sending the form to the
(ft.)
address(es)above,also submit one copy of this form within 30 days of completion
of well abandonment to the county health department of the county where
6E Inner casing/tubing length(if known): N/A (ft.) abandoned.
6g.Screen length(if known): 10 (ft.)
i
Form GW-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016