Loading...
HomeMy WebLinkAbout20230997 Ver 1_Riparian Buffer Authorization Request_20230714Original Submittal 7/14/2023 A. Owner/Applicant Information General Information Q .......................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... Primary Contact Email: * gene.mack@homevestors.com Please list the contact person's email for questions or payment on this project if needed. Who is submitting the application?* O Owner 0 Applicant other than Owner 0 Agent Is there an agent working on this application but Yes not submitting it? No 1. Property Owner Information: ............................................................................................................. 1a. Name on Recorded Deed:* 1b. Responsible Party: 1c. Mailing Address:* 1 d. Telephone:* 941-504-8705 Joseph Payton Allen III, Kathryn Lucille McKeen (for Corporations) Street Address 606 E Geer St Address Line 2 City State / Province / Region Durham NC Postal / Zip Code Country 27701 USA 1e. Email Address:* jallen77nc@gmail.com 2. Applicant's Information (if different from owner): 2a. Name: Gene Mack 2b. Company Affiliation: Abiel LLC 2c. Mailing Address: Street Address 1122 Vick Charles Dr Address Line 2 City Raleigh Postal / Zip Code 27606 2d.Telephone: 770-769-7234 2e. Email Address: gene.mack@homevestors.com State / Province / Region NC Country USA B. Project Information and Prior Project History 1. Project Information 1a. Name of Project:* Allen Property Stream Buffer Variance for New Build Home (Subdivision, facility, or establishment name) 1b. Is this a publicly -funded transportation project?* Yes No 1d. Subdivision Name: PROP -CHEEK T le. Nearest Municipality: Durham 1f. Property Size: 0.23 acres 1 g. County (or Counties) where the project is located:* Durham 1 h. Property ID# Date of Purchase 083230817201 8/7/2020 Tax PIN or Parcel id 1i. Deed Information Type of Book Book# Page# I Deed F 975 Map IF [21 1 j. Attach a copy of the recorded map that indicates when the lot was last platted. Click the upload button or drag and drop files here to attach document Recorded survey, 604 E Geer.pdf 419.26KB Buyer survey, Geer-604 E.pdf 240.2KB PDF only 1 k. How would you like to provide the Latitude and Longitude information? Address Lookup Manually Latitude* 36.003367 Longitude*-78.885490 11. Is the project located in any of North Carolina's twenty coastal counties?* Yes No 2. Surface Waters .......................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... 2a. Name of the nearest body of water to proposed project: * Ellerbe Creek, Falls Lake, Neuse River 2b. Water Quality Classification of nearest receiving water: WS-IV; NSW 2c. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property: 210 (linear feet only) 3. Project Description: 3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application: Lot is undeveloped, covered with scrub vegetation with enough poison ivy to make you itch just looking at it. Nearby sites are SFR's with commercial beginning a couple hundred feet down the road. 3b. Attach an 8 % x 11 excerpt from the most recent version of the USGS topographic map indicating the location of the site. Click the upload button or drag and drop files here to attach document USGS topo map 2019, 604 E Geer.pdf 108.38MB PDF only 3c. Attach an 8 % x 11 excerpt from the most recent version of the published County NRCS Soil Survey Map depicting the project site. Click the upload button or drag and drop files here to attach document USDA soils map June 1976, 604 E Geer.pdf 2.34MB NRCS soil map 1-2600, 604 E Geer.pdf 549.74KB NRCS soil map 1-6800, 604 E Geer.pdf 11VIB NRCS soil map 1-13900, 604 E Geer.pdf 1.15MB PDF only 4. Proposed Activity Provide a detailed description of the proposed activity including its purpose and include the type of equipment to be used: * Build a new SFR using typical methods. The proposed site plan utilizes the small -lot option and the minimum viable footprint to impact the stream buffer the least amount possible. Attach a site plan as applicable to the project: Click the upload button or drag and drop files here to attach document Site Plan w Stream Buffer Impacts, Geer-604 E.pdf 215.39KB PDF only 5. Jurisdictional Determinations 5a. Have jurisdictional wetlands or stream determinations by the Corps or State been requested or obtained for this property/project (including all prior phases) in the past?* Yes No 6. Project History 6a. Have permits or certifications been requested or obtained for this project (including all prior phases) in the past? Yes No 7. Future Project Plans ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... ......... .................. 7a. Is this project a phased project?* Yes No C. Proposed Impacts Inventory Buffer Impacts Project is in which protected Basin?* Neuse River Basin (15A NCAC 02B.0233) Catawba River Basin (15A NCAC 02B.0243) Randleman Lake Watershed (15A NCAC 02B.0250) Tar -Pamlico River Basin (15A NCAC 02B.0259) Jordan Lake Watershed (15A NCAC 02B.0267) Goose Creek Watershed (15A NCAC 02B.0606 & 15A NCAC 02B.0607) Individually list all buffer impacts below. If any impacts require mitigation, then you MUST fill out Section D of this form. Site# - Reason Stream Name Buffer Impact*IF Impact Type Zone 1 Zone 2 Pad, SFR, Deck UT - Ellerbe Creek Permanent (P) Allowable w/ 404.00 906.00 Map label (e.g. Road Crossing 1) Perm or Temp mitigation Square Feet Square Feet Total Zone 1 Impacts: 404.00 Total Zone 2 Impacts: 906.00 Total Buffer Impacts: 1,310.00 Comments: D. Impact Justification and Mitigation 1. Avoidance and Minimization la. Specifically describe measures taken to avoid or minimize the proposed impacts in designing the project. Met with Cherri Smith, Environmental Specialist with the Devision of Water Resources, to review the site and potential plans. Proposed plan utilizes the small lot option and the smallest viable house footprint in order to minimize the impact to the stream buffers. 1b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques. Per Cherri Smith, the size of the lot precludes any specific measures other than keeping construction activity out of the buffers to the maximum extent possible. 2. Buffer Mitigation 2a. The table below identifies the square footage of impact to each zone of the riparian buffer and the required mitigation. Zone 1 Total Impact Multiplier 11 Required Mitigation 404.00 3 1,212 Square Feet Square Feet Zone 2 Total Impact Multiplier IF Required Mitigation 906.00 1.50 1,359.00 Square Feet Square Feet 2b. What is the mitigation plan proposed for this M Payment to private mitigation bank project?* O Payment to Division of Mitigation (DMS) -] Permittee responsible mitigation 2e. Attach statement of availability from mitigation provider.* Click the upload button or drag and drop files here to attach document Statement of availability, 604 E Geer - Wildlands 177.53KB Engineering.pdf PDF only 2g. Comments: We are flexible and able to cooperate with any mitigation plan proposed by the dept. E. Diffuse Flow Plan 1a. What type of SCM are you providing?* Level Spreader Vegetated Conveyance (lower SHWT) Wetland Swale (higher SHWT) Proposed project will not create concentrated stormwater flow through the buffer Other SCM that removed minimum of 30% nitrogen 1 c. Diffuse Flow Documentation Click the upload button or drag and drop files here to attach document Diffuse flow plan, 604 E Geer.pdf 191.33KB PDF only F. Supplementary Informatio- Environmental Documentation 1a. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land? Yes No Violations 2a. Is the site in violation of DWR Wetland Rules (15A NCAC 02H .0500), Isolated Wetland Rules (15A NCAC 02H .1300), DWR Surface Water or Wetland Standards, or Riparian Buffer Rules (15A NCAC 02B .0200)? 2b. Is this an after -the -fact buffer authorization application? Yes No G. Additional Information Please upload any additional information you would like the Division to consider during application review. Additional Attachments: Click the upload button or drag and drop files here to attach document Buffer auth agent auth, 604 E Geer SIGNED 7-8- 168.75K6 23.pdf PDF only Additional Comments: H. Sign and Submit ......... ......... ......... ......... ......... ......... ......... ......... .... .... ...... ...... ....... ...... ......... ......... .... ...... .... ....... ....... . ......... ......... ......... ........ By digitally signing below, I certify that: o I have given true, accurate, and complete information on this form; • I agree that submission of this form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act') o I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act'); • I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND o I intend to electronically sign and submit the application form." Print Name:* Eugene Mack Signature Submission Date: (Auto populated field) Initial Review Is this accepted into the review process?* Yes No Is this project a public transportation project?* u Yes a No ID#* 20230997 Version: * Select Reviewer: * Select Reviewing Office* Has payment been received?* Chem Smith: Cherri.Smith Raleigh Regional Office - (919) 791-4200 No Payment Needed Fee Received Need Fee - send electronic notification