Loading...
HomeMy WebLinkAboutNC0051161_Compliance Evaluation Inspection_20230627ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Products SE Pipe Line Corporation PPL Attn: Jimmy Stamey, Owner 6709-A West Market Street Greensboro, NC 27409 NORTH CAROLINA Environmental Quality June 27, 2023 SUBJECT: Compliance Evaluation Inspection Greensboro Petroleum Breakout Facility NPDES Permit #: NCO051161 Guilford County On May 24th, 2023, Division of Water Resources staff Ron Boone conducted a routine compliance inspection at the Products SE Pipe Line Corporation PPL Greensboro Petroleum Breakout Facility. Kelly Joyce, Operator in Responsible Charge (ORC), and Cody McCuiston, Backup ORC, were present during the inspection. A review of records, data, treatment components, and structures was completed. This inspection reflected compliance with the subject permit. Observations: 1. All site drainage is collected in a network of containments, pipes, and ditches, and is conveyed to one of two concrete -lined wet storage ponds. 2. There are two outfalls, 001 and 002. Discharge from 001 is measured with a staff gauge and flume and discharge from 002 is measured using an ultrasonic flow device. The ultrasonic meter is checked for accuracy at least annually using a bucket and a stopwatch and comparing the result to the flow meter. 3. When it is necessary to discharge, operators evaluate condition of pond contents and open normally closed locked gate valves to release the pond contents. Effluent from both outfalls goes to East Fork Deep River, Class WS-IV* waters in the Cape Fear River Basin. 4. Discharge monitoring reports and laboratory reports for July 2022 and January 2023 were reviewed and no discrepancies were noted. No other items of concern were noted. Please be aware that pursuant to North Carolina general statute (NCGS) 143-215.6A, the Division may assess civil penalties not to exceed $25,000 per day against any person who fails to fully comply with the requirements of a permit issued pursuant to NC General Statute (NCGS) 143-215.1., as is NC0088552. DffNorth Carolina Department of Environmental Quality I Division of Water Resources oan caaouNn Winston-Salem Regional Office 1 450 W. Hanes Mill Rd, Suite 300 I Winston-Salem, North Carolina 27105 M336.776.9800 oep.m.m or em�nmen� Qualm If you have any questions or concerns, please feel free to contact Mr. Boone at any time by phone at 336- 776-9690, or by email at ron.boone@deq.nc.gov. Thank you for your time and attention to this matter. Sincerely, I D-ocuSiiggned by: I�7n. l . Jn.10.Cr 145B49E225C94EA... Lon T. Snider, Regional Supervisor Water Quality Regional Operations Section Winston-Salem Regional Office Division of Water Resources, NCDEQ Attachments: Water Compliance Inspection Report REQ� North Carolina Department ofEnvironmental Quality I Division ofWater Resources Winston-Salem Regional Office 1 450 W. Hanes Mill Rd, Suite 300 1 Winston-Salem, North Carolina 27105 NORTH CAROLINA 336.776.9800 naparMeM of EmironmanW 9uallly United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCO051161 111 121 23/05/24 I17 18 LC] I 19 I s I 20L] 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I ni I 71 I 74 79 I I I I I I I80 701 I 71 I LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 02:OOPM 23/05/24 22/08/01 Greensboro Petroleum Breakout Facility 6907-A W Market St Exit Time/Date Permit Expiration Date Greensboro NC 27409 03:OOPM 23/05/24 26/08/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Michael Kelly Joyce/ORC/336-601-2211/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted James L Stamey,6907-A W Market St Greensboro NC 27409/Operations Manager/336-547-3673/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran 0 Facility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Ron Boone DocuSigned by: DWR/WSRO WQ/336-776-9690/ o*%,*& Boo.ue' 6/27/2023 B20F8DD5F2A3460... Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date Docusigned by: FLam - T. 6/27/2023 '--- 145B49E225C94EA... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NCO051161 I11 12I 23/05/24 117 18 i c i (Cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On May 24th, 2023, Division of Water Resources staff Ron Boone conducted a routine compliance inspection at the Products SE Pipe Line Corporation PPL Greensboro Petroleum Breakout Facility. Kelly Joyce, Operator in Responsible Charge (ORC), and Cody McCuiston, Backup ORC, were present during the inspection. A review of records, data, treatment components, and structures was completed. This inspection reflected compliance with the subject permit. Observations: 1. All site drainage is collected in a network of containments, pipes, and ditches, and is conveyed to one of two concrete -lined wet storage ponds. 2. There are two outfalls, 001 and 002. Discharge from 001 is measured with a staff gauge and flume and discharge from 002 is measured using an ultrasonic flow device. The ultrasonic meter is checked for accuracy at least annually using a bucket and a stopwatch and comparing the result to the flow meter. 3. When it is necessary to discharge, operators evaluate condition of pond contents and open normally closed locked gate valves to release the pond contents. Effluent from both outfalls goes to East Fork Deep River, Class WS-IV* waters in the Cape Fear River Basin. 4. Discharge monitoring reports and laboratory reports for July 2022 and January 2023 were reviewed and no discrepancies were noted. No other items of concern were noted. Page# Permit: NCO051161 Owner - Facility: Greensboro Petroleum Breakout Facility Inspection Date: 05/24/2023 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ■ ❑ application? Is the facility as described in the permit? ■ ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ■ ❑ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: None Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ■ ❑ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ■ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ❑ ❑ ■ ❑ operator on each shift? Is the ORC visitation log available and current? ■ ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ■ ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility ■ ❑ ❑ ❑ classification? Is a copy of the current NPDES permit available on site? ■ ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ ■ ❑ Comment: Annual report is not required. Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? ■ ❑ ❑ ❑ Page# 3 Permit: NCO051161 Owner - Facility: Greensboro Petroleum Breakout Facility Inspection Date: 05/24/2023 Inspection Type: Compliance Evaluation Laboratory Yes No NA NE Are all other parameters(excluding field parameters) performed by a certified lab? 0 ❑ ❑ ❑ # Is the facility using a contract lab? ■ ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ❑ ❑ ❑ degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ 0 ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ 0 ❑ Comment: None Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ 0 ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? ■ ❑ ❑ ❑ Is the tubing clean? ❑ ❑ 0 ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ❑ ❑ ❑ ■ degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type ❑ ❑ ❑ representative)? Comment: None Lagoons Yes No NA NE Type of lagoons? Facultative # Number of lagoons in operation at time of visit? 2 Are lagoons operated in? # Is a re -circulation line present? ❑ 0 ❑ ❑ Is lagoon free of excessive floating materials? 0 ❑ ❑ ❑ # Are baffles between ponds or effluent baffles adjustable? ❑ ❑ 0 ❑ Are dike slopes clear of woody vegetation? 0 ❑ ❑ ❑ Are weeds controlled around the edge of the lagoon? 0 ❑ ❑ ❑ Are dikes free of seepage? 0 ❑ ❑ ❑ Are dikes free of erosion? ■ ❑ ❑ ❑ Are dikes free of burrowing animals? 0 ❑ ❑ ❑ # Has the sludge blanket in the lagoon (s) been measured periodically in multiple ❑ ❑ 0 ❑ locations? # If excessive algae is present, has barley straw been used to help control the growth? ❑ ❑ 0 ❑ Page# 4 Permit: NCO051161 Inspection Date: 05/24/2023 Lagoons Is the lagoon surface free of weeds? Is the lagoon free of short circuiting? Comment: None Owner - Facility: Greensboro Petroleum Breakout Facility Inspection Type: Compliance Evaluation Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: None Yes No NA NE ■ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: None Page# 5