Loading...
HomeMy WebLinkAbout20230971 Ver 1_ePCN Application_20230706DWR Division of Water Resources Pre -Construction Notification (PCN) Form For Nationwide Permits and Regional General Permits (along with corresponding Water Quality Certifications) April 13, 2022 Ver 4.3 Initial Review Has this project met the requirements for acceptance in to the review process? Yes No Is this project a public transportation project?* Yes No Change only If needed. Pre -Filing Meeting Date Request was submitted on: 5/3/2023 BIMS # Assigned 20230971 Is a payment required for this project?* No payment required Fee received Fee needed - send electronic notification Reviewing Office* Mooresville Regional Office - (704) 663-1699 Information for Initial Review la. Name of project: Crossroads - Locust Elm St. 1a. Who is the Primary Contact?* Heath Caldwell 1b. Primary Contact Email: * heath.caldwell@wetiands-epg.com Date Submitted 7/6/2023 Nearest Body of Water Island Creek Basin Catawba Water Classification C Site Coordinates Latitude: 35.2519 A. Processing Information Is this project connected with ARPA funding? Yes No County (or Counties) where the project is located: Stanly Is this a NCDMS Project Yes No Longitude: -80.4106 Version#* 1 What amout is owed?* $240.00 $570.00 Select Project Reviewer* Andrew Pitner:andrew.pitner@ncdenr.gov 1c. Primary Contact Phone: * (704)999-5279 Is this project a public transportation project?* Yes No 1a.Type(s)of approval sought from the Corps: Section 404 Permit (wetlands, streams and waters, Clean Water Act) Section 10 Permit (navigable waters, tidal waters, Rivers and Harbors Act) Has this PCN previously been submitted?* Yes No Please provide the date of the previous submission. 5/4/2020 1b. What type(s) of permit(s) do you wish to seek authorization? Nationwide Permit (NWP) Regional General Permit (RGP) Standard (IP) 1c. Has the NWP or GP number been verified by the Corps? Yes No Nationwide Permit (NWP) Number: NWP Numbers (for multiple NWPS): 1d. Type(s) of approval sought from the DWR: 401 Water Quality Certification - Regular Non-404 Jurisdictional General Permit Individual 401 Water Quality Certification 29 - Residential Developments le. Is this notification solely for the record because written approval is not required? For the record only for DWR 401 Certification: For the record only for Corps Permit: 1f. Is this an after -the -fact permit application? * Yes No 1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? Yes No 1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? Yes No 1h. Is the project located in any of NC's twenty coastal counties? Yes No 1j. Is the project located in a designated trout watershed? Yes No B. Applicant Information 1d. Who is applying for the permit? Owner Applicant (other than owner) le. Is there an Agent/Consultant for this project? Yes No 2. Owner Information 2a. Name(s) on recorded deed: DR Horton 2b. Deed book and page no.: 2c. Contact Person: Jon Burgess 2d.Address Street Address 8025 Arrowridge Blvd Address Line 2 City Charlotte Postal / Zip Code 28273 401 Water Quality Certification - Express Riparian Buffer Authorization Stale / Province / Region North Carolina Country USA * Yes No Yes No 2e. Telephone Number: (704)574-8545 2g. Email Address:* JBBurgess@drhorton.com 2a. Name(s) on recorded deed: Judy Barbee 2b. Deed book and page no 2c. Contact Person: 2d.Address Street Address 707 Elm St Address Line 2 city Locust Postal / Zip Code 28097 2e. Telephone Number: (704)888-4215 2g. Email Address:" JBBurgess@drhorton.com 3. Applicant Information (if different from owner) 3a. Name: Jon Burgess 3b. Business Name: DR Horton 3c.Address Street Address 8025 Arrowridge Blvd Address Line 2 City Charlotte Postal / Zip Code 28273 3d. Telephone Number: (704)574-8545 3f. Email Address:* JBBurgess@drhorton.com 4. Agent/Consultant (if applicable) 4a. Name: Heath Caldwell 4b. Business Name: Leonard S. Rindner, PLLC - Wetlands & Environmental Planning Group 4c.Address Street Address 10612-D Providence Road, PMB 550 Address Line 2 city Charlotte Postal / Zip Code 28227 4d. Telephone Number: (704)999-5279 4f. Email Address:* kelsey.strausbaugh@wetlands-epg.com 2f. Fax Number: State / Province / Region North Carolina Country USA 2f. Fax Number: State / Province / Region North Carolina Country USA 3e. Fax Number: State / Province / Region North Carolina Country USA 4e. Fax Number: C. Project Information and Prior Project History 0 1. Project Information 1b. Subdivision name: (if appropriate) 1c. Nearest municipality / town: Oakboro 2. Project Identification 2a. Property Identification Number: 2c. Project Address Street Address Address Line 2 city Postal / Zip Code 3. Surface Waters 3a. Name of the nearest body of water to proposed project: " Island Creek 3b. Water Resources Classification of nearest receiving water: C 3c. What river basin(s) is your project located in?* Catawba 3d. Please provide the 12-digit HUC in which the project is located. 030401050703 4. Project Description and History 2b. Property size: State / Province / Region Country 4a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application: * Following commencement of construction, majority of the site has been converted to lots for residential developments, including roadways and utility installations. The remaining surrounding forested area consists of mixed pine and hardwood forest that is disturbed throughout. 4b. Have Corps permits or DWR certifications been obtained for this project (including all prior phases) in the past? Yes No Unknown If yes, please give the DWR Certification number or the Corps Action ID (exp. SAW-0000-00000). (SAW-2019-02037)/ DWR#20-0621 4f. List the total estimated acreage of all existing wetlands on the property: 0.851 4g. List the total estimated linear feet of all existing streams on the property: 7.118 4h. Explain the purpose of the proposed project:* The residential development included permanent impacts to two streams and two wetlands for road crossing access and utility installation which have been installed. 41. Describe the overall project in detail, including indirect impacts and the type of equipment to be used: Excavation and grading of the site used standard equipment - excavator, dump trucks, track hoe, etc. 5. Jurisdictional Determinations 5a. Have the wetlands or streams been delineated on the property or proposed impact areas?* Yes No O Unknown Comments: 5b. If the Corps made a jurisdictional determination, what type of determination was made? Preliminary Approved Not Verified Unknown N/A Corps AID Number: SAW-2019-02037 5c. If 5a is yes, who delineated the jurisdictional areas? Name (if known): Nicholas Nelson Agency/Consultant Company: WEPG Other: 5d. List the dates of the Corp jurisdiction determination or State determination if a determination was made by the Corps or DWR A Preliminary Jurisdictional Determination request was submitted on 10/16/19 (SAW-2019-02037) and was field verified by Bryan Roden Reynolds on 1/9/20. 6. Future Project Plans 6a. Is this a phased project?* Yes No Are any other NWP(s), regional general permit(s), or individual permits(s) used, or intended to be used, to authorize any part of the proposed project or related activity? This is an after the fact permit submittal. Installation of proposed impacts required additional impacts above what was previously permitted. Additional rip -rap was placed due to the orientation of the stream at the base of the retaining wall at Impact 2 for stabilization purposes. The pipe at Impact 2 was lengthened to accommodate the right of way/roadway requirements at the crossing. D. Proposed Impacts Inventory 1. Impacts Summary 1a. Where are the impacts associated with your project? (check all that apply): Wetlands Streams -tributaries O Buffers Open Waters Pond Construction 2. Wetland Impacts a 2a1 Reason (?) Fill 2b. Impact type * M P 2c. Type of W. * Headwater Forest 2d. W. name Wetland U 2e. Forested * Yes 2f. Type of Jurisdicition * (?) Corps 2g. Impact area * 0.040 (acres) Fill P Headwater Forest Wetland B E:::J.rp. J�::::] 2g. Total Temporary Wetland Impact 0.000 2g. Total Wetland Impact 0.070 2i. Comments: 3. Stream Impacts 2g. Total Permanent Wetland Impact 0.070 F 3a. Reason for impact (?) 3b.lmpact type* 3c. Type of impact* 3d. S. name* 3e. Stream Type* 3f. Type of 3g. S. width 3h. Impact (?) Jurisdiction* length* S1 Road Crossing - Impact 1 Permanent Culvert Stream S Perennial Corps 55 Average (feet) (linear feet) g2 Road Crossing - Impact 1 Permanent Fill Stream S Perennial Corps 41 Averege (feet) (linear feet) S3 Road Crossing - Impact 2 Permanent Culvert Stream A Perennial Corps 6 75 Average (feet) (linear feet) S4 Road Crossing - Impact 2 Permanent Fill Stream A Perennial Corps 6 47 Averege (feet) (linear feet) SS Utility Installation Temporary Excavation Stream A Perennial Corps 40 Average (feet) (linear feet) 3i. Total jurisdictional ditch impact in square feet: 0 3i. Total permanent stream impacts: 3i. Total temporary stream impacts: 218 40 3i. Total stream and ditch impacts: 258 3j. Comments: Riprap used for streambank stabilization upstream and downstream of each crossing was installed at pre -construction streambed elevations and should not contribute to a loss of Waters of the US. Total loss to Waters of the US for the proposed project includes 130 LF of stream impacts. Temporary stream impact on S5 is for open cut utility installation. All impacts are currently installed. E. Impact Justification and Mitigation O 1. Avoidance and Minimization la. Specifically describe measures taken to avoid or minimize the proposed impacts in designing the project: Due to the location of the on site streams and wetlands, opportunities to completely avoid these areas were limited. Impacts to site surface waters associated with the proposed development were limited through site selection location, design, location/orientation of the proposed lots and access routes. Rip rap placed within the stream, located at the upstream and downstream sides of each crossing, was designed to minimize impacts but provide appropriate energy dissipation per HEC-14 guidelines. All installed rip rap was placed at pre -construction streambed elevations. 1b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques: Construction techniques used implemented approved erosion control methods to avoid/minimize impacts to onsite/adjacent offsite receiving conveyances. 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State? Yes No 2b. If this project DOES NOT require Compensatory Mitigation, explain why: The applicant has demonstrated substantial avoidance and minimization efforts in which 98.2 of the original 7,248 linear feet of stream channel and 92.4 % of the original 0.921 acres of wetlands onsite will be avoided. Due to the limited amount of anticipated impacts to site surface waters, no mitigation is proposed for the development. F. Stormwater Management and Diffuse Flow Plan (required by DWR) 1. Diffuse Flow Plan la. Does the project include or is it adjacent to protected riparian buffers identified within one of the NC Riparian Buffer Protection Rules? Yes No If no, explain why: 2. Stormwater Management Plan 2a. Is this a NCDOT project subject to compliance with NCDOT's Individual NPDES permit NCS000250? Yes No 2b. Does this project meet the requirements for low density projects as defined in 15A NCAC 02H .1003(2)? Yes No 2c. Does this project have a stormwater management plan (SMP) reviewed and approved under a state stormwater program or state -approved local government stormwater program? Yes No N/A - project disturbs < 1 acre 2d. Which of the following stormwater management program(s) apply: Local Government State Local Government Stormwater Programs Phase II NSW USMP Water Supply Please identify which local government stormwater program you are using. City of Locust Comments: G. Supplementary Information 1. Environmental Documentation la. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land? Yes No 2. Violations (DWR Requirement) 2a. Is the site in violation of DWR Water Quality Certification Rules (15A NCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), or DWR Surface Water or Wetland Standards or Riparian Buffer Rules (15A NCAC 2B .0200)? * Yes No u 2b Provide an explanation of the violation(s): 3. Cumulative Impacts (DWR Requirement) 3a. Will this project result in additional development, which could impact nearby downstream water quality? Yes No 3b. If you answered "no," provide a short narrative description. All phases are included within this application. 4. Sewage Disposal (DWR Requirement) 4a. Is sewage disposal required by DWR for this project?" Yes No N/A 4b. Describe, in detail, the treatment methods and dispositions (non -discharge or discharge) of wastewater generated from the proposed project. If the wastewater will be treated at a treatment plant, list the capacity available at that plant. Wastewater generated on the site will be transported to the nearest treatment facility via sewer lines. 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or habitat?" Yes No 5b. Have you checked with the USFWS concerning Endangered Species Act impacts?" Yes No 5d. Is another Federal agency involved? * Yes No Unknown 5e. Is this a DOT project located within Division's 1-8? Yes No 5f. Will you cut any trees in order to conduct the work in waters of the U.S.? Yes No 5g. Does this project involve bridge maintenance or removal? Yes No 5h. Does this project involve the construction/installation of a wind turbine(s)?* Yes No 5i. Does this project involve (1) blasting, and/or (2) other percussive activities that will be conducted by machines, such as jackhammers, mechanized pile drivers, etc.? Yes No 5j. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? A Threatened/Endangered species assessment was conducted prior to commencement of construction in 2020 in which no species were identified. 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as an Essential Fish Habitat? Yes No 6b. What data sources did you use to determine whether your site would impact an Essential Fish Habitat? No essential fish habitat in this region. 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation status? Yes No 7b. What data sources did you use to determine whether your site would impact historic or archeological resources? SHPO's website: http://gis.ncdcr.gov/hpoweb/ 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA-designated 100-year floodplain? Yes No 8c. What source(s) did you use to make the floodplain determination? https://stanly.connectgis.com/Map.aspx Miscellaneous Please use the space below to attach all required documentation or any additional information you feel is helpful for application review. Documents should be combined into one file when possible, with a Cover Letter, Table of Contents, and a Cover Sheet for each Section preferred. Click the upload button or drag and drop files here to attach document Locust Elm St_ UpdatedPCN_Binder.pdf 18.73MB File must be PDF or KMZ Comments Signature By checking the box and signing below, I certify that: • The project proponent hereby certifies that all information contained herein is true, accurate, and complete to the best of my knowledge and belief'; and • The project proponent hereby requests that the certifying authority review and take action on this CWA 401 certification request within the applicable reasonable period of time. • I have given true, accurate, and complete information on this form; • I agree that submission of this PCN form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act"); • I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act"); • I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND • I intend to electronically sign and submit the PCN form. Full Name: Heath Caldwell Signature �� &461*011V Date 7/6/2023 M