HomeMy WebLinkAboutWQ0034367_Monitoring - 05-2023_20230626Monitoring Report Submittal
Permit Number#* W00034367
Name of Facility:* Onslow Water and Sewer Authority - Northwest Regional WRF
Month: * May Year: * 2023
Report Information
Type* Upload Document*
NDMR, NDAR-1, NDAR-2, NDMLR NWRWRF NDAR & NDMR May 2023.pdf 4.6MB
PDF Only
Please upload one PDF containing all applicable monitoring reports
(i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59).
Confirmation Email Address: * sjones@onwasa.com
Name of Submitter: * Sherry Jones
Signature:
Date of submittal: 6/26/2023
This will be filled in automatically
Initial Review
Reviewer: Wanda.Gerald
Is the project number correct?* WQ0034367
Is the monitoring report accepted?* Yes No
Regional Office* Wilmington
Reviewer: _anonymous
Review Date: 7/11/2023
FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page _L_ of
Permit No.: W00034367
PPI: 001 Flow Measuring
Facility Name: Northwest Regional Water Reclamation Facility
Point: ❑ Influent ❑� Effluent ❑ No Flow generated Parameter
County: Onslow
MonitoringPoint: ❑ Influent
month: May
Effluent
❑ [I Groundwater Lowering
Year: 2023
❑Surface Water
Parameter Code No
50050
00310
00940
50060
31616
00610
00625
00620
00600
00400
00665
70300
00530
00076
CV
0
>
v
E
UQ ~
0
0
C
N
U
0
3
o
_
y
o
15 ao
U
i
11p
1U
o
0
.. Z
�
z
m
M
O00
Z
.2 L
0
0
(L
>�
OE NnONo
Ln
yavc a
CD
rtN
U)
F;a7Y-
24-hr
hrs
GPD
mg/L
mg/L
mg/L
#/100 mL
mg/L
mg/L
mg/L
mg/L
su
mg/L
mg/L
mg/L
NTU
1
12:00
:8
609,000
2.3
0.13
<1.00
<0.500
1.41
2.89
3.12
6.92
1.54
<2.50
1.07
2
10:00
8
446,100
4.1
0.13
1
<0.500
1.09
5.49
5.7
6.86
1.61
<2.50
1.09
3
08:00
8
458,600
3.6
0.19
<1.00
<0.500
1.08
1.66
1.77
6.93
1.95
<2.50
1.02
4
08:30
8.5
665,900
0.16
1
6.89
1.16
5
10:00
4
620,800
0.17
6.92
1.42
6
164,100
0.15
7.01
1.33
7
405,900
0.16
6.94
1.5
8
09:15
5
392,900
5.5
0.28
1
<0.500
1.32
3.1
3.35
7.01
2.71
3.3
2.94
9
09:00
8.75
380,600
5.5
0.1
<1.00
<0.500
1.48
2.54
2.79
6.95
2.82
2.6
1.63
10
10:00
4
509,800
6.6
0.22
<1.00
<0.500
1 1.53
2.39
2.62
7.1
2.85
3.1
2.14
11
08:00
6
0
NO Flow
12
08:05
6
710,600
0.16
7.16
3.45
13
410,500
0.23
6.92
2.99
14
361,100
0.21
6.94
3.1
15
10:30
7
311,100
6.7
0.18
<1.00
<0.500
2.38
2.01
2.08
7.05
1.61
3.6
2.75
16
07:00
10
391,400
7.1
0.2
<1.00
<0.500
1.54
1.4
1.45
7.03
1.71
2.8
2.9
17
07:00
12.5
885,500
6.5
0.1
<1.00
<0.500
1.56
1.51
1.58
7.34
1.75
3
2.85
18
07:00
12
412,600
0.13
7.17
2.84
19
08:30
6
492,400
0.17
7.07
2.87
20
03:35
6.5
206,700
0.01
7.11
2.4
21
08:00
10
609,400
0.2
7
2.3
22
09:45
6
91,100
9.1
0.03
<0.500
2.56
0.452
0.494
7.02
2.75
3.2
3.4
23
09:00
5
362,200
9.1
1.1
<1.00
<0.500
2.17
<0.250
<0.250
7.04
2.7
<2.50
3.56
24
08:30
8.75
319,000
9.3
0.38
3
<0.500
2.38
<0.250
0.25
6.97
2.74
3
3.41
25
09:00
8.33
412,900
0.13
<1.00
6.99
3.62
26
08:30
6.5
356,900
0.47
7.02
6.52
27
199,800
0.39
7.2
3.78
28
363,400
0.23
7.13
3.98
29
H
H
349,900
0.17
7.08
5.49
30
0915
5.75
458,600
17.6
0.25
<1.00
6.52
7.3
<0.250
<0.250
7.31
3.98
5.6
8.64
311
09:00
7.5
342,200
26.8
0.17
1
8.39
9.52
<0.250
<0.250
7.28
2.63
5.2
5.46
Average:
409,710
8.56
0.22
1.08
1.07
2.67
1.67
1.80
2.38
2.53
3.05
0.00
Daily Maximum:
885,500
26.80
1.10
3.00
8.39
9.52
5.49
5.70
7.34
3.98
5.60
8.64
0.00
Daily Minimum:
0
2.30
0.01
1.00
0.50
1.08
0.25
0.25
6.86
1.54
2.50
1.02
0.00
Sampling Type:
Recorder
Composite
Composite
Grab
Grab
Composite
Composite
Composite
Composite
Grab
Composite
Composite
Composite
Recorder
Monthly Avg. Limit:
11272,973
10
14
4
10
7
3
5
Daily Limit:
15
25
6
6.0 - 9.0
10
10
Sample Frequency:
Continuous
3 x Week
3 x Year
5 x Week
3 x Week
3 x Week
3 x Week
3 x Week
3 x Week
5 x Week
3 x Week
3 x Year
3 x Week
Continuous
FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page 7, of_�,
Permit No.: WQ0034367
PPI: 002 Flow Measuring
Facility Name: Northwest Regional Water Reclamation Facility
Point: ❑ Influent ❑ Effluent ❑� No Flow generated Parameter
County: Onslow
MonitoringPoint: ❑ Influent
Month: May
❑Effluent ❑✓ Groundwater Lowering
Year: 2023
❑Surface Water
Parameter Code
50050
00310
00680
00940
31616
00300
00610
00625
00620
00600
00400
00665
70300
0
U P
C
OR
~ N
of
O
_O
E
0
m
U
C
O
`
C' �
oU
v
L
U
E
V w
LL O
U
UI C
� �
-6 cm
N X
o 0
c
O
E
a
a C
am
N 07
Y _0
:°Z
o
F-
�;
f0
w`
Z
C
«
0
Z
_
CL
_
L
H N
0
a
'O
m N
r>
5 0
t� O
~ yco
o
24-hr
hrs
GPD
mg/L
mg/L
mg/L
#1100 mL
mg/L
mg/L
mg/L
mg/L
mg/L
su
mg/L
mg/L
1
12:00
8
0
2
10:00
8
0
3
08:00
8
0
4
08:30
8.5
0
5
10:00
4
0
6
0
7
0
8
09:15
5
0
9
09:00
8.75
0
10
10:00
4
0
11
08:00
6
0
12
08:00
6
0
13
0
14
0
15
10:30
7
0
16
07:00
10
0
17
07:00
12.5
0
18
07:00
12
0
19
08:30
6
0
20
03:35
6
0
21
08:00
10 1
0
22
09:45
6
0
23
09:00
5
0
24
08:30
8.75
0
25
09:00
8.33
0
26
08:30
6.5
0
27
0
28
0
29
H
H
0
30
09:15
5.75
0
31
09:00
7.5
0
Average:
0
Daily Maximum:
0
Daily Minimum:
0
Sampling Type:
Recorder
Grab
Grab
Grab
Grab
Grab
Grab
Grab
Grab
Grab
Grab
Grab
Grab
Monthly Avg. Limit:
250
1
1.5
10
500
Daily Limit:
482,632
6.5 - 8.5
Sample Frequency:
Continuous
2 x Month
3 x Year
3 x Year
2 x Month 1
2 x Month
2 x Month
2 x Month
2 x Month
2 x Month
2 x Month
2 x Month
3 x Year
FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page *� of4!�
Permit No.: III .
• -st Regional Water- •
•
1
11
'• ■ ■ ■
.WINNE•. ■
•
•
•
m
1: 1----------------
1. /1
®®----------------
FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page C of �'
Permit No.: WQ0034367
114
Facility Name: Northwest-• • -r Reclamation.
'• ■ ■ ■
Onslow
•. ■
Month: May1
•
•
•
DaiLy Maximum -
Daily Minimum:
FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page _� ofll�
Sampling Person(s)
Name: Mark Young
Name: Perry Parker, Dakota Marston, Ryan Baker, Randal Riggs
Certified Laboratories
Name: ONWASA Laboratory Cert. # 539
Name: Envirochem Cert. # 94
Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit?
❑ Compliant ❑✓ Non -Compliant
If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective
action(s) taken. Attach additional ghPatg if naraggary
The plant had Daily violations for BOD and Ammonia on the last 2 days of the month. As part of the Hurricane Florance Recovery Project, the SBRs were returned to automation the week of the 15th. Due to
the change from the manual operation to a more fluid automated operation we believe this may have contributed to the BOD some but mostly believe the redundant chlorine feed is more likely the cause and we
also observed an increase in the COD samples collected. The chlorine pumps have been temporarily linked to the post EQ pumps but the operators control was limited on the feed rate. We have worked with
the SCADA intergrator to fix this issue and the operators now have better control to adjust the feed rates. In additions, the chemical feed pumps for the SBR process were not linking properly to the operational
program which resulted in less than desired chemical feed to the SBR. Other adjustments for the down time of blowers and mixer pump have been adjusted to reduce idle time and better maintain dissolved
oxygen and mixing.We have notified the Wilmington Regional Office and will continue to update them on our progress and any further violations. The plant had no flow on the 11th due to the SBR inlet valve
breaking down which prevented the plant from running a batch on that day. The valve was repaired and returned to service.
Operator in Responsible Charge (ORC) Certification Permittee Certification
ORC: Mark Young Permittee: Onslow Water and Sewer Authority
Certification No.: 1001105 Signing Official: David Mohr
Grade: 4 Phone Number: 910-937-7570 Signing Official's Title: Chief Operations Officer
Has the ORC hanged since the previous NDMR? ❑ Yes El No Phone Number: 910 937-7521 Permit Expiration: 2/28/2029
1.7 04&-C 1 IV.4 & -o� &
Sig ure ate Signature ate
By this signature, I certi at this r t is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that all qualified personnel property gathered and evaluated the information
submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for
gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am
aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for
knowing violations.
Mail Original and Two Copies to:
Division of Water Resources
Information Processing Unit
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
FORM: NDAR-2 10-13 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page / of Zi
Permit No.: WQ0034367
Facility Name: Northwest Regional WRF
County: Onslow
Month: May
Year: 2023
Did infiltration occur at
Site Name:
Basin A
Site Name:
Basin B
Site Name:
Basin C
Site Name:
Basin D
this facility?
❑�
Area (acres):
2.37
Area (acres):
1.73
Area (acres):
1.73
Area (acres):
1.17
YES ❑ NO
Rate (GPD/ft):
8.736
Rate (GPD/ft):
3.286
Rate (GPD/ft):
0.72
Rate (GPD/ft):
1.408
Weather
Freeboard
Site Infiltrated?
❑Q YES ❑ NO
Site Infiltrated?
❑� YES ❑ No
Site Infiltrated?
❑ YES NO
Site Infiltrated?
❑ YES NO
A
cv
U>
O
U
41
t
N
C
E
N
F-
O
i
_
C
U
`
M
M
07 c0
f0 .0
O C
C
N
N .0
C M
�. C
C
0 10
L6
a) N
C
O C
i Q
d d
Co
_''
C
T O
6
l0 16
O O
J
a
N OC
O N
0 C
y
LL m
a) D
= •_
C
O C
% Q
N
d
a+
F
C
O)
? C
c0
O
J
�'
C
O O
a C
�
to
LL m
d 'O
E d
O C
O C
� Q
y
d
w+
i- -
M
>, _C
F
p A
..0.1
a'
a
p O
.0 N
N S
y
LL m
41 a
of
3 Q.
O p
i Q
N
N O
E �,
f" v-
C
O]
C_
'� •O
`°
p 0
J
>'
C
0 O
c
`.
LL
00
°F
in
ft
ft
gal
min
GPD/ftZ
ft
gal
min
GPD/ft2
ft
gal
min
GPD/ft2
ft
gal
min
GPD/ftZ
ft
1
C
51
0
8.4
502,400
1440
4.87
16.00
106,600
1440
1.41
16.00
0
0
0.00
14.00
0
0
0.00
12.20
2
C
50
0
8.4
369,700
1440
3.58
16.00
76,400
1440
1.01
16.00
0
0
0.00
14.00
0
0
0.00
12.20
3
CL
45
0
8.4
380,100
1440
3.68
16.00
78,500
1440
1.04
16.00
0
0
0.00
14.00
0
0
0.00
12.20
4
C
44
0
8.4
550,900
1440
5.34
16.00
115,000
1440
1.53
16.00
0
0
0.00
14.00
0
0
0.00
12.20
5
PC
46
0
8.4
506,200
1440
4.90
16.00
114,600
1440
1.52
16.00
0
0
0.00
14.00
0
0
0.00
12.20
6
CL
51
0
8.4
164,100
1440
1.59
16.00
26,900
1440
0.36
16.00
0
0
0.00
14.00
0
0
0.00
12.30
7
C
56
0
8.4
336,400
1440
3.26
16.00
69,500
1440
0.92
16.00
0
0
0.00
14.00
0
0
0.00
12.30
8
c
65
0
8.7
320,200
1440
3.10
16.00
72,700
1440
0.96
16.00
0
0
0.00
14.00
0
0
0.00
12.30
9
C
67
0
8.7
319,300
1440
3.09
16.00
61,300
1440
0.81
16.00
0
0
0.00
14.00
0
0
0.00
12.30
10
R
52
0.14
8.7
429,500
1440
4.16
16.00
80,300
1440
1.07
16.00
0
0
0.00
14.00
0
0
0.00
12.30
11
C
53
0
8.7
0
0
0.00
16.00
0
0
0.00
16.00
0
0
0.00
14.00
0
0
0.00
12.30
12
C
54
0
8.7
596,100
1440
5.77
16.00
114,500
1440
1.52
16.00
0
0
0.00
14.00
0
0
0.00
12.30
13
PC
57
0
8.7
345,100
1440
3.34
1.6.00
65,400
1440
0.87
16.00
0
0
0.00
14.00
0
0
0.00
12.30
14
R
68
0.02
8.7
301,200
1440
2.92
16.00
59,900
1440
0.79
16.00
0
0
0.00
14.00
0
0
0.00
12.30
15
C
55
0
8.7
257,400
1440
2.49
16.00
53,700
1440
0.71
16.00
0
0
0.00
14.00
0
0
0.00
12.30
16
CL
62
0
8.7
325,400
1440
3.15
16.00
66,000
1440
0.88
16.00
0
0
0.00
14.00
0
0
0.00
12.30
17
C
70
0
8.7
744,300
1440
7.21
16.00
141,200
1440
1.87
16.00
0
0
0.00
14.00
0
0
0.00
12.30
18
R
61
0.02
8.7
347,700
1440
3.37
16.00
66,900
1440
0.89
16.00
0
0
0.00
14.00
0
0
0.00
12.30
19
R
63
1.02
8.7
417,300
1440
4.04
16.00
75,100
1440
1.00
16.00
0
0
0.00
14.00
0
0
0.00
12.30
20
CL
63
0
8.8
173,200
1440
1.68
16.00
33,500
1440
0.44
16.00
0
0
0.00
14.00
0
0
0.00
12.30
21
CL
68
0
8.8
505,900
1440
4.90
16.00
103,500
1440
1.37
16.00
0
0 1
0.00
14.00
0
0
0.00
12.30
22
C
50
0
8.8
78,900
1440
0.76
16.00
12,200
1440
0.16
16.00
0
0
0.00
14.00
0
0
0.00
12.30
23
C
58
0
8.8
305,100
1440
2.96
16.00
57,100
1440
0.76
16.00
0
0
0.00
14.00
0
0
0.00
12.40
24
CL
58
0
8.8 1
271,400
1440 1
2.63
16.00
47,600
1440
0.63
16.00
0
0
0.00
14.00
0
0
0.00
12.40
25
R
57
0.05
8.8
341,100
1440
3.30
16.00
71,800
1440
0.95
16.00
0
0
0.00
14.00
0
0
0.00
12.40
26
R
58
0.34
8.8
297,800
1440
2.88
16.00
59,100
1440
0.78
16.00
0
0
0.00
14.00
0
0
0.00
12.40
27
R
56
0.95
8.8
172,200
1440
1.67
16.00
27,600
1440
0.37
16.00
0
0
0.00
14.00
0
0
0.00
12.50
28
R
64
0.48
8.8
318,200
1440
3.08
16.00
45,200
1440
0.60
16.00
0
0
0.00
14.00
0
0
0.00
12.50
29
CL
64
0
8.8
302,200
1440
2.93
16.00
47,700
1440
0.63
16.00
0
0
0.00
14.00
0
0
0.00
12.50
30
R
E64
0.21
8.8
394,200
1440
3.82
16.00
64,400
1440
0.85
16.00
0
0
0.00
14.00
0
0
0.00
12.50
31
CL
0
8.8 1
279,400
1440
2.71
16.00
62,800
1440
0.83
16.00
0
0
0.00
14.00
0
0
0.00
12.50
Monthly Loading (GPD/ft):
Year to Date Loadin (GPD/ftZ):
3.33
17.51
RI
0.89
3.76
0.00
b
FORM: NDAR-2 10-13 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page Z_ of ?I
-
Did the application rates exceed the limits in Attachment B of your permit?
If not a basin, were the sites kept free of vegetation and raked?
If not a basin, were there any instances of effluent ponding in or runoff from the sites?
If a basin, were there any instances of breakout from the berms?
Was the onsite automatically activated standby power source tested and operational?
0 Compliant
❑ Non -Compliant
❑� Compliant
❑ Non -Compliant
❑� Compliant
❑ Non -Compliant
0 Compliant
❑ Non -Compliant
❑� Compliant
❑ Non -Compliant
If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective
action(s) taken. Attach additional sheets if necessarv.
Operator in Responsible Charge (ORC) Certification
Permittee Certification
ORC: Mark C. Young
Permittee:
Onslow Water & Sewer Authority
Certification No.: 1001105
Signing Official: David Mohr
Grade: 4 Phone Number: 910-455-0722
Signing Official's Title: Chief Operations Officer
Has the ORC changed since the previous NDAR-2? ❑ Yes 0 No
Phone Number: 910-937-7521 Permit Exp.: 2/28/29
C GQ 11
06 Z,3 2b
ign ure Date
Ify
Signature ate
By this signature, I that this report is accurrate and complete to the best of my knowledge.
I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance
with a system designed to assure that all qualified personnel property gathered and evaluated the information submitted. Based on my
inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the
information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant
penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations.
Mail Original and Two Copies to:
Division of Water Resources
Information Processing Unit
1617 Mail Service Center
Raleigh, North Carolina 27699-1617