Loading...
HomeMy WebLinkAboutWQ0020248_Monitoring - 05-2023_20230620Monitoring Report Submittal Permit Number#* WQ0020248 Name of Facility:* Big Buffalo Waste Water Treatment Plant Month: * May Year: * 2023 Report Information Type* Upload Document* NDMR, NDAR-1, NDAR-2, NDMLR 2023 05 NDMR BB.pdf 1.55MB PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). Confirmation Email Address: * scott.siletzky@sanfordnc.net Name of Submitter: * Scott A. Siletzky Signature: Date of submittal: 6/20/2023 This will be filled in automatically Initial Review Reviewer: Wanda.Gerald Is the project number correct?* W00020248 Is the monitoring report accepted?* Yes NO Regional Office* Raleigh Reviewer: _anonymous Review Date: 7/10/2023 FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page � of Q, Permit No.: W00020248 Facility Name: Big Buffalo Waste Water Treatment Plant County: Lee Month: May Year: 2023 PPI: 001 Flow Measuring Point: ❑ Influent ❑ Effluent Z No flow generated Parameter Monitoring Point: Lj Influent Effluent ❑ Groundwater Lowering ❑ Surface Water Parameter Code 0 50050 00310 00530 00610 00076 31616 p t aE �� O r O m P v O 3 ° LL p O m a co c'a oQ'o F' in N m o E E Q a o LLU 24-hr hrs GPD mg/L mg/L mg/L NTU #/100 mL 1 07:00 5.5 0 2 0700 6 0 3 07:00 6 0 4 07:00 6.5 0 5 07:00 5.5 0 6 0 7 0 8 07:00 5.5 0 9 07:00 6.5 0 10 07:00 7 0 11 07:00 6.5 0 12 07:00 4 0 13 0 14 0 15 07:00 5 0 16 07:00 6 0 17 07:00 5.5 0 18 07:00 5.5 0 19 07:00 6 0 20 0 21 0 221 07:00 4 0 23 07:00 6.5 0 24 07:00 4 0 25 07:00 6.5 0 26 07:00 6 0 27 0 28 0 29 07:00 Holiday 0 30 07:00 6 0 31 07:00 4 0 Average: 0 Daily Maximum: 0 Daily Minimum: 0 Sampling Type: Recorder Composite Composite Composite Recorder Grab Monthly Avg. Limit: 10 5 4 14 Daily Limit: 15 10 6 10 25 Sample Frequency: 1 2 X Week 2 X Week 5 X Week Continous 2 X Month FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page of Sampling Person(s) Certified Laboratories Name: Dale Deaton Name: Waypoint Analytical Name: Jacob Flinchum Name: Meritech Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? J❑ Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. IA Operator is at the facility 24 hours a day! The ORC time is based on how long the day. The Backup served as the ORC on May 12th. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Scott A Siletzky Permittee: City Of Sanford Certification No.: 24383 Signing Official: Scott A. Siletzky Grade: WW-4 Phone Number: 919-777-1781 Signing Official's Title: Water Reclamation Adminstrator Has the ORC changed since the previous NDMR? ❑ Yes [21 No Phone Number: 919-777-1781 Permit Expiration: 12/31/2026 LLW4f::, I cic� I a3 G I ab ,�3 Signature Date Signature Date By this signature, 1 certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617