HomeMy WebLinkAboutSW6221102_Plansheet EC-4 - Misc. Detail_202211287 rn I N N 11-1 r 00 r ) f�� vi w U w W 0 i W L 0 i ca a� Q N N Islit i • •l CLEAR THE ENTRANCE AND EXIT AREA OF ALL VEGETATION, ROOTS AND OTHER OBJECTIONABLE MATERIAL AND PROPERLY GRADE IT. PLACE THE GRAVEL TO THE SPECIFIC GRADE AND DIMENSIONS SHOWN ON THE PLANS AND SMOOTH IT. PROVIDE DRAINAGE TO CARRY WATER TO A SEDIMENT TRAP OR OTHER SUITABLE OUTLET. USE GEOTEXTILE FABRICS BECAUSE THEY IMPROVE STABILITY OF THE FOUNDATION IN LOCATIONS SUBJECT TO SEEPAGE OR HIGH WATER TABLE. MAINTENANCE: MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOPDRESSING WITH 2" STONE. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN 1T OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED OR TRACKED ONTO PUBLIC ROADWAYS. 2"-3" COURSE AGGREGATE @ 6" DEEP MINIMUM WITH FILTER FABRIC UNDERLINER NTRAN C E /EXIT D ETAI L NOT TO SCALE PIPE OUTLET O o O� CS'O m O o o� ooc�oo cS� � 0 o0oQo 00 0 Q0 gl 00 g CLASS RIP —RAP VARIES PIPE OUTLET \V1 FLOW IT I I O CJo O cp "THICKNESS" --I I-- 12" FILTER FABRIC TO BE INSTALLED UNDER ALL RIP —RAP CONSTRUCTION SPECIFICATIONS 1. ENSURE THAT THE SUBGRADE FOR THE FILTER AND RIPRAP FOLLOWS THE REQUIRED LINES AND GRADES SHOWN IN THE PLAN. COMPACT ANY FILL REQUIRED IN THE SUBGRADE TO THE DENSITY OF THE SURROUNDING UNDISTURBED MATERIAL. LOW AREAS IN THE SUBGRADE ON UNDISTURBED SOIL MAY ALSO BE FILLED BY INCREASING THE RIPRAP THICKNESS. 2. THE RIPRAP AND GRAVEL FILTER MUST CONFORM TO THE SPECIFIED GRADING LIMITS SHOWN ON THE PLANS. 3. FILTER CLOTH, WHEN USED, MUST MEET DESIGN REQUIREMENTS AND BE PROPERLY PROTECTED FROM PUNCHING OR TEARING DURING INSTALLATION. REPAIR ANY DAMAGE BY REMOVING THE RIPRAP AND PLACING ANOTHER PIECE OF FILTER CLOTH OVER THE DAMAGED AREA. ALL CONNECTING JOINTS SHOULD OVERLAP SO THE TOP LAYER IS ABOVE THE DOWNSTREAM LAYER A MINIMUM OF 1 FOOT. IF THE DAMAGE IS EXTENSIVE, REPLACE THE ENTIRE FILTER CLOTH. 4. RIPRAP MAY BE PLACED BY EQUIPMENT, BUT TAKE CARE TO AVOID DAMAGING THE FILTER. 5. THE MINIMUM THICKNESS OF THE RIPRAP SHOULD BE 1.5 TIMES THE MAXIMUM STONE DIAMETER. 6. RIPRAP MAY BE FIELD STONE OR ROUGH QUARRY STONE. IT SHOULD BE HARD, ANGULAR, HIGHLY WEATHER —RESISTANT AND WELL GRADED. 7. CONSTRUCT THE APRON ON ZERO GRADE WITH NO OVERFILL AT THE END. MAKE THE TOP OF THE RIPRAP AT THE DOWNSTREAM END LEVEL WITH THE RECEIVING AREA OR SLIGHTLY BELOW IT. 8. ENSURE THAT THE APRON IS PROPERLY ALIGNED WITH THE RECEIVING STREAM AND PREFERABLY STRAIGHT THROUGHOUT ITS LENGTH. IF A CURVE IS NEEDED TO FIT SITE CONDITIONS, PLACE IT IN THE UPPER SECTION OF THE APRON. 9. IMMEDIATELY AFTER CONSTRUCTION, STABILIZE ALL DISTURBED AREAS WITH VEGETATION (PRACTICES 6.10, TEMPORARY SEEDING, AND 6.11, PERMANENT SEEDING). MAINTENANCE INSPECT RIPRAP OUTLET STRUCTURES WEEKLY AND AFTER SIGNIFICANT (1 /2 INCH OR GREATER) RAINFALL EVENTS TO SEE IF ANY EROSION AROUND OR BELOW THE RIPRAP HAS TAKEN PLACE, OR IF STONES HAVE BEEN DISLODGED. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE. OUTLET STABILIZATION STRUCTURE NOT TO SCALE REVISIONS SYM. DESCRIPTION DATE Engineering, PLLC 150 S. Page Street • Southern Pines, NC 28387• (910) 684-8646 • Cert. No. P-2587 2' MIN. rNr%L 1r1 A l%Tr-r% e1r%11 NOTES: BUILD RIDGE HIGHER THAN DESIGN AND COMPACT WITH WHEELS OF CONSTRUCTION EQUIPMENT. COMPACTED RIDGE MUST BE AT OR ABOVE DESIGN GRADE AT ALL TIMES. LEAVE SUFFICIENT AREA ALONG DIVERSION TO PERMIT CLEANOUT AND REGRADING. CONSTRUCTION SPECIFICATION 1.REMOVE AND PROPERLY DISPOSE OF ALL TREES, BRUSH, STUMPS, AND OTHER OBJECTIONABLE MATERIAL. 2.ENSURE THAT THE MINIMUM CONSTRUCTED CROSS SECTION MEETS ALL DESIGN REQUIREMENTS. DIKE IS NOT LOWER AT ANY POINT THAN THE DESIGN ELEVATION 3.ENSURE THAT THE TOP OF THE DIKE IS NOT LOWER AT ANY POINT THAN THE DESIGN ELEVATION PLUS THE SPECIFIED SETTLEMENT. 4.PROVIDE SUFFICIENT ROOM AROUND DIVERSIONS TO PERMIT MACHINE REGRADING AND CLEANOUT. 5.VEGETATE THE RIDGE IMMEDIATELY AFTER CONSTRUCTION, UNLESS IT WILL REMAIN IN PLACE LESS THAN 30 WORKING DAYS. MAINTENANCE INSPECT TEMPORARY DIVERSIONS ONCE A WEEK AND AFTER EVERY RAINFALL. IMMEDIATELY REMOVE SEDIMENT FROM THE FLOW AREA AND REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETS AND MAKE TIMELY REPAIRS AS NEEDED. WHEN THE AREA PROTECTED IS PERMANENTLY STABILIZED, REMOVE THE RIDGE AND THE CHANNEL TO BLEND WITH THE NATURAL GROUND LEVEL AND APPROPRIATELY STABILIZE IT. TEMPORARY DIVERSION DITCH NOT TO SCALE WIRE FENCING AND CONSTRUCTION SPECIFICATIONS: WOVEN GEOSYNTHETIC FILTER FABRIC CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR EXTRA vc STEEL POSTS STRENGTH SYNTHETIC FILTER FABRICS. 8' O.C. W/WIRE ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED EXTEND FABRIC AND 24" ABOVE THE GROUND SURFACE. (HIGHER FENCES MAY IMPOUND WIRE INTO TRENCH VOLUMES OF WATER SUFFICIENT TO CAUSE FAILURE OF THE STRUCTURE.) COMPACTED CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE BACKFILL K, LENGTH OF THE BARRIER TO AVOID JOINTS. WHEN JOINTS ARE NECESSARY, = _x SECURELY FASTEN THE FILTER CLOTH ONLY AT A SUPPORT POST WITH 4' Q MINIMUM OVERLAP TO THE NEXT POST. a _, :j: `: ;: SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED ;�VI'`y r 00 SECURELY TO THE UPSLOPE SIDE OF THE POSTS. EXTEND THE WIRE MESH SUPPORT TO THE BOTTOM OF THE TRENCH. FASTEN THE WIRE REINFORCEMENT, THEN FABRIC ON THE UPSLOPE SIDE OF THE FENCE ts:;:._ POST. WIRE OR PLASTIC ZIP TIED SHOULD HAVE MINIMUM 50 POUND I � . ` r { ' o TENSILE STRENGTH. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM OF 8 APART. SUPPORT POSTS SHOULD BE DRIVEN SECURELY INTO THE NOTE' GROUND A MINIMUM OF 24" REMOVE SEDIMENT DEEPER T EXTRA STRENGTH FILTER FABRIC WITH 6' POST SPACING DOES NOT REQUIRE 12". REPAIR ANY UNDERMINE WIRE MESH SUPPORT FENCE. SECURELY FASTEN THE FILTER FABRIC IMMEDIATELY. DIRECTLY TO POSTS. WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH. EXCAVATE A TRENCH APPROXIMATELY 4" WIDE AND 8" DEEP ALONG THE MAINTENANCE PROPOSED LINE OF POSTS AND UPSLOPE FROM THE BARRIER. INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. PLACE 12" OF THE FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR COMPACT. THOROUGH COMPACTION OF THE BACKFILL IS CRITICAL TO SILT BECOME INEFFECTIVE, REPLACE IT PROMPTLY. FENCE PERFORMANCE. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE 0 THE FENCE. TAKE DO NOT ATTACH FILTER FABRIC TO EXISTING TREES. CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. TEMPORARY SILT FENCE DETAIL NOT TO SCALE EROSION CONTROL UTILITY IMPROVEMENTS AUG 2022 `sDETAILS DATE TO SERVE ASHLEY HEIGHTS FINAL DRAWINGS � '' ''� HOKE COUNTY., NORTH CAROLINA -4 NOT RELEASED FOR CONSTRUCTION t�•II'Z.Z SHEET NO.