Loading...
HomeMy WebLinkAboutSW6230501_1924-Submittal Letter_20230511 site solutions May 11, 2023 civil engineering I land surveying NCDEQ Division of Water Quality Attn: Brianna Holland 512 N. Salisbury Street Raleigh, NC 27604 RE: Storm water resubmittal, Ila's Way Subdivision, Harnett County, North Carolina Brianna; We received the initial review comments per email dated May 1. The comments have been addressed as noted below. • Please add the following items to the plans: o Wetland delineation or a note on the plans stating that there are no wetlands located on-site.This item is required per 15A NCAC 02H .1042(2)(g)(iii) & Section VI, 8m of the Application. Please also list the name of the individual that made this determination in a note on the plans. ■ Note has been added o Vegetated setback from surface waters.This item is required per 15A NCAC 02H .1042(2)(g) &Section VI, 8p of the Application.The USGS indicates a stream adjacent to the site. If the stream is within the required 30'vegetated set back, please show the set back on the plans.Vegetated setbacks are required from all surface waters, including offsite surface water. More information can be found in 15A NCAC 02H .1003(4) & .1017(10). ■ The offsite stream is not within 30' of the site. No streams are within 30' of the property. o Drainage area delineation to each swale. (This item is required per 15A NCAC 02H .1042(2)(g)(iv) &Section VI, 8o of the Application). ■ Drainage area sheet has been completed and enclosed • Please correct the following issues with the Application: o Section II, 5-This project is located within 5 miles of an airport(Harnett Regional Jetport). Please revise. ■ Done • Please provide 1x hard copy of a soils report with the project area clearly delineated. This item is required per Section VI, 9 of the Application. https://websoiIsurvey.nres.usda.gov/apP/WebSoiISurvey.aspx ■ Done • Please correct the following issues with the Supplement-EZ Form: 409 Chicago Drive, Suite 112, Fayetteville, NC 28306 office 1 910-426-6777 fax 1 910-426-5777 On time,every time. I www.4DsitesoLutions.com o Cover, Compliance with 02H .1003(4): Line 7-8—Please fill in.Vegetated setbacks are required from all surface waters, including offsite surface water. If the USGS identified surface water is not within 30' of the site,this section is still required to be filled in. Per 15A NCAC 02H .1017 (10),the vegetated setback shall be at least 30 feet in width. ■ Done Two copies of the revised plan sheet are enclosed as well as the soils report and updated pages from the storm water application and supplement. I look forward to working with you on this project. If you have any questions or concerns, please contact me at your earliest convenience. Sincerely, 4D Site Solutions, Inc Scott Brown, PE sbrown@4dsitesolutions.com Enclosure 2