Loading...
HomeMy WebLinkAboutSW4211102_add info_20230105 oF�E STATE os� �Py ROY COOPER > Governor O ELIZABETH S.BISER Secretary *`�`QUAM BRIAN WRENN NORTH CAROLINA Director Environmental Quality January 5, 2022 Aden Stoltzfus, PE 683 Gralin Street Kernersville,NC 27284 AND Aiken & Charlotte Keppler 721 Ancient Oaks Drive Holly Springs,NC 27540 Subject: Request for Additional Information Stormwater Permit No. SW4211102 Store-It-Safe Self-Storage Alamance County Dear Mr. Stoltzfus and Mr. & Mrs. Keppler: The Division of Energy, Mineral and Land Resources (DEMLR), received a Stormwater Management Permit Application for the subject project on November 11, 2021. A review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: 1. Please provide sizing calculations for the riprap dissipators demonstrating that the inlets and outlet of the proposed sand filter is stable in accordance with General MDC 4. It is noted that the riprap sizing has been provided on plan sheet C3,but it does not appear as though the sizing calculations have been provided. 2. Since the Applicant is also the Property Owner, Section IX of the Application(the property owner certification) does not need to be signed. With your permission, I can cross out the provided signature on the original hard copy that I have. If this is not acceptable, please provide a revised original Application with only Section X signed. 3. Please ensure that all of the submission items from the initial hard copy submission (such as the Application,plan set, O&M Agreement Form, property deed, calculations, soil borings, etc...) are electronically submitted. It appears as though only the items that were requested on 10/25/2021 were electronically provided. D E Q�� North Carolina Department of Environmental Quality I Division of Energy,Mineral and Land Resources 512 North Salisbury Street 1 1612 Mail Service Center I Raleigh,North Carolina 27699-1612 NORTH CAROLINA _ uep�m of Ummemeemi ue.nh 919.707.9200 4. It is recommended to bypass any off-site portions of the area draining to the proposed SCM around the SCM. Any off-site portions of the drainage area that are not bypassed must be accounted for at their full built-out potential(per 15A NCAC 02H .1003(3)(b)) which is typically assumed to be 100%BUA. It is noted that the proposed sand filter is oversized to the point that it currently has the additional capacity that would be required if the entire off-site portion of the drainage area were assumed to be 100% BUA. If you do not plan on, or are unable to, bypass this off-site area, please make a note in the Supplement-EZ Form stating that the sand filter is oversized to account for the off-site area being developed to its full build-out potential(100%BUA). However, it is still recommended to bypass this off-site drainage area since the Applicant does not own this area (and therefore has no control over what future development happens in this area). It is possible (but unlikely) that the adjoining property owner could develop their property in a manner that directs more stormwater runoff into the sand filter than it was originally designed to handle and make the sand filter non-complaint despite the Applicant not doing anything to cause this non-compliance (bypassing this off-site area would prevent this from happening). 5. Provide pdfs of all revisions, 2 hardcopies of revised plan sheets, 1 hardcopy of other documents, and a response to comments letter briefly describing how the comments have been addressed. a. Pdfs must be uploaded using the form at: https:,[/edocs.deg..nc.gov/Forms/SW-Supplemental-Upload b. Hard copies must be mailed or delivered to the following address: i. For FedEx/UPS: Jim Farkas 512 N. Salisbury Street, Office 640E Raleigh,NC 27604 ii. For LISPS: Jim Farkas 1612 Mail Service Center Raleigh, NC 27699-1612 iii. Hand Delivery: Please reach out to me prior to hand delivering a submission to make sure that I (or someone else in my group)will be able to receive the submission. Do not leave the package in the foyer with the security guard. We do not always get alerted that something has been dropped off for us, and more often than not, it just sits there until someone notices that it is missing. NOTE: Hard copies should not be sent to a Regional Office. Doing so will delay the review process and the submission package may be lost while being sent from the Regional Office to me in the Central Office. NOTE: We have recently been experiencing issues with not receiving some package deliveries. Please ensure that the delivery address is written as shown. You may wish to add a tracking number to your submission as this helps us find wayward packages. Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to February 4, 2022, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. Please reference the State assigned project number SW4211102 on all correspondence. If you need additional time to submit the information,please submit your request for a time extension to the Division at the contact below. The request must indicate the date by which you expect to submit the required information. The Division is allowed 90 days from the receipt of a completed application to issue the permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. If you have any questions concerning this matter please feel free to contact me at Jim.Farkas&ncdenr.gov or(919) 707-3646. Sincerely, Jim Farkas Environmental Engineer Stormwater Program cc: Winston-Salem Regional Office