Loading...
HomeMy WebLinkAbout20230549 Ver 1_USACE Permit_20230630U.S. ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Action Id. SAW-2023-00402 County: Guilford U.S.G.S. Quad: NC -Browns Summit GENERAL PERMIT (REGIONAL AND NATIONWIDE) VERIFICATION Permittee: Blu Ladder Construction, LLC Attn: Jay Gaffney Address: 108 State Street, Suite 300 Greensboro, NC 27408 E-mail: jay.gaffneyAblu-ladder.com Size (acres) —21.3 Nearest Town Greensboro Nearest Waterway UT to Unnamed Tributary at Camp Herman River Basin Cape Fear USGS HUC 03030002 Coordinates 36.164805,-79.723572 Location description: The pro*ect area is located on the northeast side of Esterwood Road, approximately 0.2 mile northwest of its intersection with US Highway 29, in Greensboro, Guilford County, North Carolina. Description of projects area and activity: This verification authorizes the discharge of fill material into 0.019 acre (166 linear feet) of stream channel (0.016 acre 1136 linear feet] of which is considered a permanent loss) and the temporary discharge of fill material into 0.001 acre (10 linear feet) of stream channel, necessary to construct access and infrastructure for the Greens Village multi -family residential development. Applicable Law(s): ® Section 404 (Clean Water Act, 33 USC 1344) ❑ Section 10 (Rivers and Harbors Act, 33 USC 403) Authorization: Nationwide Permit 29. Residential Developments SEE ATTACHED NWP GENERAL, REGIONAL, AND/OR SPECIAL CONDITIONS Your work is authorized by the above referenced permit provided it is accomplished in strict accordance with the attached Conditions, your application signed and dated 4/17/2023additional information received via email on 5/24/2023, and the enclosed plans "Greens Village" "Master Site Plan", "Detailed Site Plan — South", "Detailed Site Plan — North", and "Crossing Exhibit." Any violation of the attached conditions or deviation from your submitted plans may subject the permittee to a stop work order, a restoration order, a Class I administrative penalty, and/or appropriate legal action. This verification will remain valid until the expiration date identified below unless the nationwide and/or regional general permit authorization is modified, suspended or revoked. If, prior to the expiration date identified below, the nationwide and/or regional general permit authorization is reissued and/or modified, this verification will remain valid until the expiration date identified below, provided it complies with all requirements of the modified nationwide permit. If the nationwide and/or regional general permit authorization expires or is suspended, revoked, or is modified, such that the activity would no longer comply with the terms and conditions of the nationwide permit, activities which have commenced (i.e., are under construction) or are under contract to commence in reliance upon the nationwide and/or regional general permit, will remain authorized provided the activity is completed within twelve months of the date of the nationwide and/or regional general permit's expiration, modification or revocation, unless discretionary authority has been exercised on a case -by -case basis to modify, suspend or revoke the authorization. Activities subject to Section 404 (as indicated above) may also require an individual Section 401 Water Quality Certification. You should contact the NC Division of Water Resources (telephone 919-807-6300) to determine Section 401 requirements. For activities occurring within the twenty coastal counties subject to regulation under the Coastal Area Management Act (LAMA), prior to beginning work you must contact the N.C. Division of Coastal Management. This Department of the Army verification does not relieve the permittee of the responsibility to obtain any other required Federal, State or local approvals/permits. If there are any questions regarding this verification, any of the conditions of the Permit, or the Corps of Engineers regulatory program, please contact David E. Bailey at (919) 817-2436 o David.E.Bailey2(a,usace.army.mil. Coms Re2ulatory Official: Date: 06/30/2023 Expiration Date of Verification: 3/15/2026 SAW-2023-00402 SPECIAL CONDITIONS 1. Please note that future impacts and/or phases of the Greens Village residential development, and related activities associated with Corps Action ID: SAW-2023-00402, may be considered part of a single and complete project; these impacts may be considered cumulative with impacts authorized during earlier phases with respect to compensatory mitigation and Nationwide Permit thresholds. Current cumulative impacts to waters of the US for the Greens Village single and complete project include a total loss of 0.016 acre (136 linear feet) of stream channel/potential waters of the US. Corps Regulatory Official: Date: 06/30/2023 Expiration Date of Verification: 3/15/2026 The Wilmington District is committed to providing the highest level of support to the public. To help us ensure we continue to do so, please complete the Customer Satisfaction Survey located at https://regulatory.ops.usace.gM.mil/customer-service-survey. Copy furnished electronically: Michael Brame, Pilot Environmental, Inc., mbrame@pilotenviro.com Seren Homer, NCDEQ-DWR, seren.homergncdenngov Rebecca Chandler, NCDEQ-DWR, rebecca.chandlerkncdenr.gov GENERAL NOTES: 1. AREA DETERMINED UTILIZING COMPUTER SOFTWARE. 2. GRID TIE INFORMATION BASED ON MONUMENTATION AND DATUM AS SHOWN, ALL DISTANCES ARE GROUND DISTANCES (US FEET) UNLESS OTHERWISE SHOWN. 3. NO NGS MONUMENTS WERE RECOVERED WITHIN 2000' OF THIS PROPERTY. 4. NO SUBSURFACE INVESTIGATION PERFORMED BY FLEMING ENGINEERING, INC. 5. UTILITY LOCATION WORK SHOWN HEREON WAS DERIVED BY ABOVE GROUND INDICATORS ONLY, UNLESS OTHERWISE NOTED. 6. THIS PROPERTY IS SUBJECT TO ANY EASEMENTS, AGREEMENTS OR RIGHTS OF WAY RECORDED PRIOR TO THE DATE OF THIS MAP WHICH WERE NOT VISIBLE AT THE TIME OF INSPECTION. 7. THE SURVEYOR HAS NOT PERFORMED A TITLE INVESTIGATION ON THIS PROPERTY, THEREFORE, THIS MAP IS SUBJECT TO ANY AND ALL FACTS AN ACCURATE TITLE INVESTIGATION MAY DISCLOSE. 8. THIS MAP DOES NOT MEET G.S. 47-30 AND IS NOT FOR RECORDING OR CONVEYANCE. 9. THE CLASSIFICATION OF THIS SURVEY IS NORTH CAROLINA CLASS A. 10. HORIZONTAL DATUM: NAD83(2011). 11. ANY SIGNS TO BE PLACED ON SITE MUST BE SUBMITTED SEPARATELY FOR ZONING REVIEW. 12. PATIO/OVER HANG AREA IS GOING TO BE AN OPEN AREA THAT SHARES THE SAME ROOF AS THE OFFICE BUILDING. 13. ANY STRUCTURE TO BE REMOVED SHALL REQUIRE A SEPARATE DEMOLITION PERMIT FROM THE BUILDING INSPECTIONS DEPARTMENT. 14. MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED THROUGHOUT EXIT DISCHARGES IN ACCORDANCE WITH NCBC. 15. ALL EXISTING AND PROPOSED OVERHEAD POWER LINES ARE INDICATED ON THE SITE PLAN. IF NO OVERHEAD POWER LINES ARE INDICATED, THERE SHALL BE NONE WITHIN 10 FEET OF THE PROPERTY LIMITS. 16. HANDICAP SIGNAGE SHALL BE INSTALLED ON FACE OF BUILDING. CONTRACTOR TO COORDINATE LOCATION WITH OWNER AND ARCHITECTURAL PLANS. SITE PLAN NOTES: 1. ALL CONSTRUCTION SHALL CONFORM TO THE LATEST CITY OF GREENSBORO, GUILFORD COUNTY PLANNING & EROSION CONTROL, NCDEQ AND NCDOT STANDARDS AND SPECIFICATIONS. 2. ALL DIMENSIONS SHOWN ON SITE PLAN ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. 3. SOIL UNDER BUILDINGS AND PAVED AREAS SHALL BE COMPACTED TO STANDARD PROCTOR MAXIMUM DRY DENSITY AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER AND SHALL CONFORM TO CITY OF GREENSBORO REQUIREMENTS WITHIN PUBLIC RIGHT OF WAY. 4. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR TO CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811 ". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND/OR RELOCATION OF ALL EXISTING UTILITIES IN COORDINATION WITH THE APPROPRIATE UTILITY, AGENCY, OR COMPANY. CONTRACTOR TO COORDINATE ACTIVITIES WITH UTILITY COMPANIES INVOLVED IN ANY RELATED RELOCATION (I.E. POWER POLES, TELEPHONE PEDESTALS, WATER METERS, ETC.). 6. EXISTING UTILITIES SHOWN ARE BASED ON FIELD SURVEYS AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY CONDITIONS PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND THE PLANS SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 7. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. STORMWATER MANAGEMENT INFORMATION 1. THIS PROPERTY IS LOCATED WITHIN FLOOD ZONE X (ZONE X AREAS ARE DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN) AREA AS INDICATED ON THE FLOOD INSURANCE RATE MAP (FIRM) MAP NUMBER 3710788700J, EFFECTIVE DATE JUNE 18TH, 2007. 2. BUILT UPON AREA (BUA) TOTAL AREA: 930,079 SF 21.35 ACRES EXISTING BUA: 103,237 SF 2.37 ACRES (11.10%) EXISTING BUA TO BE REMOVED: 87,556 SF 2.01 ACRES (9.40%) PROPOSED BUILT UPON AREA: 280,091 SF 6.43 ACRES (30.12%) TOTAL BUA: 295,772 SF 6.79 ACRES (31.80%) 3. ALL NECESSARY APPROVALS HAVE BEEN (WILL BE) OBTAINED FROM NCDEQ AND U.S. ARMY CORPS OF ENGINEERS FOR ANY WETLAND DISTURBANCE AND STREAM CROSSING/DISTURBANCE WHERE APPLICABLE. 4. ENGINEER'S CERTIFICATION OF STORMWATER QUANTITY CONTROL: THE NET INCREASE IN BUILT -UPON AREA IS GREATER THAN 400 SQUARE FEET, THEREFORE, THIS DEVELOPMENT IS SUBJECT TO 30-12-7.2(B)(7)(b) OF THE GREENSBORO LAND DEVELOPMENT ORDINANCE. 5. ALL PUBLIC STORM SEWER MUST BE INSTALLED PER NCDOT SPECIFICATIONS. 6. PRIOR TO PUBLIC STORM SEWER INSTALLATION, CONTACT CHAD MANESS AT (336) 373-2336 TO SCHEDULE THE ASSIGNMENT OF AN INSPECTOR. SITE LIGHTING NOTE 1. THE OUTDOOR SITE LIGHTING SHALL COMPLY WITH CITY OF GREENSBORO GENERAL DEVELOPMENT STANDARD 30-9-6. TRANSPORTATION NOTES: 1. NO PLANTINGS OR OTHER OBJECTS SHALL BE WITHIN SIGHT TRIANGLES AT A HEIGHT BETWEEN 2.5' AND 10' (CANOPY) ABOVE THE FINISHED GRADE OF THE PROPOSED DRIVEWAY OR WITHIN ANY STREET INTERSECTION SIGHT TRIANGLE. 2. NO VEHICLES ACCESSING THIS SITE SHALL BACK TO OR FROM THE PUBLIC RIGHT OF WAY. 3. NO VEHICLES ACCESSING THIS SITE SHALL QUEUE IN THE PUBLIC RIGHT OF WAY. 4. REFERENCE COG STD. 416-A FOR ACCEPTABLE DRIVEWAY GRADES (SEE SHEET 26 OF 29). 5. DRIVEAY TO BE CONSTRUCTED PER COG 416-B (SEE SHEET 26 OF 29). 6. SIDEWALK TO BE CONSTRUCTED PER COG 418-A (SEE SHEET 26 OF 29). 7. REPAIR/REPLACE/INSTALL ANY DAMAGED OR MISSING CURB AND GUTTER ALONG PROPERTY FRONTAGE PER 30" COG 501. 8. REPAIR/REPLACE/INSTALL ANY DAMAGED OR MISSING SIDEWALK ALONG PROPERTY FRONTAGE PER COG 418-A. 9. PRIOR TO INSTALLATION OF PUBLIC SIDEWALK AND/OR DRIVEWAYS WHICH ARE TO BE PERMITTED THROUGH DEVELOPMENT SERVICES (BUILDING INSPECTIONS) CALL 336-373-2155. AFTERWARDS, CONTACT ROADWAY INSPECTIONS AT 336-373-2336 WHEN SIDEWALK AND/OR DRIVEWAYS ARE READY FOR INSTALLATION. 10. MAINTAIN A 5' UTILITY CLARENCE AT DRIVES. 11. PROVIDE MINIMUM 4' SIDEWALK WIDTH CLEARANCE AROUND ALL ABOVE GROUND UTILITIES. UTILITY NOTES: 1. ALL CONSTRUCTION TO COG/NCDEQ STDS. 2. TERMINATE EXISTING, UNUSED WATER/SEWER TO THE MAIN TO COG STD. 3. METER, BACKFLOW PREVENTER AND ENCLOSURES TO COG STD. 4. ALL STANDARD NCDEQ/COG REQUIRED UTILITY SEPARATIONS MUST BE PROVIDED. 5. CONTACT JAY GUFFEY (336-373-7779) FOR A LIST OF APPROVED CONTRACTORS TO MAKE TAPS ON REHABILITATED MAINS. 6. COORDINATE METER REMOVAL WITH COG METER SHOP. #336-373-2071 7. THERE IS NOT A FIRE PUMP ASSOCIATED WITH THIS PROJECT. ZONING NOTES: 1. PERMITTED USES SHALL BE LIMITED TO ALL USES PERMITTED IN THE RM-18 ZONING DISTRICT EXCEPT LAND CLEARING AND INERT DEBRIS LANDFILLS, MINOR (ACCESSORY USE). 2. THE MINIMUM SEPARATION DISTANCE FROM MULTI -FAMILY BUILDINGS TO ADJACENT PARKING OR DRIVE AISLE IS 10'. 3. MAXIMUM ALLOWED BUILDING LENGTH IS 250'. 4. ZONING INFORMATION: STREET SETBACK: 20' SIDE STREET SETBACK: 15' THOROUGHFARE SETBACK: 35' SIDE AND REAR SETBACKS: ABUTTING R-DISTRICTS OR SINGLE FAMILY DWELLINGS SIDE: 20', REAR: 40' ABUTTING ANY OTHER DISTRICT: SIDE: 15', REAR: 20' TREE CONSERVATION/RESTORATION AREA: TCA REQUIRED: 10.00% x 23.82 ACRES (1,037,599 SF) = 2.38 (103,673 SF) REFORESTATION RATE: 400 SF PER 2" CALIPER TREE -90,328.897 SF / 400 SF = 225.82 = (226) 2" CALIPER TREES REQUIRED - (226) 2" CALIPER TREES X 400 S.F. = 90,328.897 S.F. TCA PROVIDED: 2.40 AC (104,544 S.F.) TREE CONSERVATION NOTES: 1. CONTACT THE PLANNING DIRECTOR TO SCHEDULE A PRE -CONSTRUCTION MEETING BEFORE ANY TREE DISTURBANCE, EXCEPT AS NOTED IN SEC. 30-4-26.3(C)(5)., OCCURS ON THIS SITE. 2. ALL TREE CONSERVATION DEVICES MUST BE INSTALLED BEFORE INSPECTION BY THE PLANNING DIRECTOR AND BEFORE ANY TREE DISTURBANCE ACTIVITIES, EXCEPT AS NOTED IN SEC. 30-4-26.3(C)(5), OCCUR. 3. REMOVAL OF OR DAMAGE TO TREES IN THE TREE CONSERVATION AREA WILL BE SUBJECT TO ALL AVAILABLE REMEDIES AND PENALTIES UNDER THE CITY'S DEVELOPMENT ORDINANCE. 4. NO PARKING, STORAGE, DIRT STOCKPILING, CONCRETE WASHOUT OR ANY OTHER ACTIVITIES IS PERMITTED IIN THE TREE CONSERVATION AREA. PARCEL#: 84098 i 40 /5 LANDSCAPING: 1. PER COG DEVELOPMENT ORDINANCE 30-10-2.5 C: ON LOTS OF RECORD THAT EXISTED PRIOR TO JULY 1, 1992 THAT ARE LESS THAN 55,000 SQUARE FEET IN AREA, NO DEVELOPMENT IS REQUIRED TO LANDSCAPE MORE THAN 15% OF THE SITE. 2. A MINIMUM 5-FOOT WIDE PLANTING YARD WITH A COMBINATION OF VEGETATION AND/OR OPEN DECORATIVE FENCING AT LEAST 2.5 FEET IN HEIGHT AND A MAXIMUM OF 3.5 FEET IN HEIGHT SHALL BE PROVIDED AT OWNER'S DISCRETION 3. STREETSCAPE CANOPY TREES ARE SPREAD OUT WITHIN SITE DUE TO SITE CONSTRAINTS. 4. NO NEW TREES OR THE PROJECTED MATURE CANOPY ALLOWED WITHIN 10' OF EXISTING/PROPOSED WATER AND SEWER. LANDSCAPE BUFFER YARD: PLANTING YARD TYPE: C AVERAGE WIDTH: 15 FT LENGTH: 3,880 FT CANOPY TREES (2 PER 100 FT): REQUIRED: 78 PROVIDED: 78 UNDERSTORY TREES (3 PER 100 FT): REQUIRED: 117 PROVIDED: 117 SHRUBS (17 PER 100 FT): REQUIRED: 660 PROVIDED: 660 STREET PLANTING YARD PARKING LOT LANDSCAPING: PARKING AREA: 1 TREE PER 12 SPACES CANOPY TREES REQUIRED: 24 PROVIDED: 24 TOTAL LANDSCAPING PROVIDED WIDTH: 10 FT LENGTH: 1,120 FT 0 CANOPY TREES: 125 CANOPY TREES (2 PER 100 FT): REQUIRED: 23 UNDERSTORY TREES: 117 PROVIDED: 23 ® SHRUBS (17 PER 100 FT): SHRUBS: 851 REQUIRED: 191 PROVIDED: 191 PARCEL# PIN OWNER ❑B PG PB PG ZONING LUC 127289 7887-58-5347 GLADYS COBLE FAMILY FARM LLC 7493 1713 R-3 1 84046 7887-68-8902 LARRY WILLIAM WHITE 3425 1690 R-3 1 84041 7887-69-6090 MARVIN L. WOMACK 6496 642 R-3 1 84040 7887-69-5078 APRIL BANKS- SWANSON 6636 2778 R-3 1 84043 7887-69-4184 JAMESA LIVENGOOD 7121 2250 R-3 1 84044 7887-69-3169 DAVID MICHAEL MORRISON 4946 71 62 76 R-3 1 84026 7887-68-5609 KEELEY REALTY GREENSBORO LLC 7493 1713 LI 4 84038 7887-59-7191 JEFFREYALLAN KINTUP 4496 1425 76 166 R-3 1 84107 7888-50-3391 JASON JAKE & MANDY ELAINE SWOFFORD 4135 260 14 14 R-3 1 W55 7888-50-7217 HOBERT H & NORA B BURLESON 2717 95 125 150 84098 7889-50-8448 HOBERT H & NORA B BURLESON 4561 606 14 68 R-3 1 84047 7888-71-3155 STATE OF NORTH CAROLI NA 2662 159 PI 3 84048 7887-79-1354 DEPARTMENT OF TRANSPORTATION 8564 2056 HB 3 84033 7887-79-0013 DEPARTMENT OF TRANSPORTATION 8514 577 RS-30 1 84041 7887-59-5463 DALY MANAGEMENT LLC 8556 2901 R-3 1 84041 7887-59-9824 DALY MANAGEMENT LLC 8556 2901 R-3 1 EASEMENT OF INGRESS, EGRESS AND REGRESS D.B. 2103 PG. 615 (30' ON EACH SIDE OF N , PROPERTY LINE) �o �� 69 0 c� w J d� w0 �co 0< zz Om gNpgR� � �v0 o T� �o p � w co 71 9NTq u' <ti SIT CARLALN �P wr,TFA 0 ir z 0 VICINITY MAP 1 "=2000' V °v, \S 89021-02" E EXISTING 30' �< UTILITY ESMT. PARCEL#: 84055 / j GSA 124.25 (TO BE REMOVED) j ZONE ZONE ��v v - /�/ FUTURE 30 STREAM BUFFER 20 STREAM BUFFER - J OPEN / / O Ir��/ l SPACE NCDOT R/W ZONE 2 ZONE 1 co- J �- - - - - // �WIDTH VARIES \ 20' STREAM BUFFER 30' STREAM BUFFER coo LO 11 EXISTING 20' o*' 0 / C\l00 UTILITY ESMT. / / TOTAL AREA. TIE TO EX .SSMH / RIM ELEV. 720.75 \ \ Z I 40' SETBACK ii i 13.85 AC 7\ PARCEL#: 8410i 1 20' LANDSCAPE CITY OF V� ice' / BUFFER \ / / GREENDBORO VARIABLE WIDTH \� / / / PERMANENT UTILITY 41 SS8o33 i EASEMENT �, 0,>11 I' OPEN UNDISTURBED 5 D.B.DB6891 PG. \ D.B. 6711 PG. 2703, \ 13 GREEN AREA & �� SAS 20' SETBACK �GJQ i ry ,� D.B. 6801 PG. 732 \ TREE CONSERVATION �3nW~� �3 15' LANDSCAPE rol / //ice' 6 / �0y / /C^ / ch BUFFER (TYP.) N / O '� i CN i// ZONE 2 ` � ,l o 00 PARCEL#: 84047 20' STREAM BUFFER \ \w, �/ V/�. / V� �,.� / / '4 // / / ZONE 1 30' STREAM BUFFER \ Z. +\ %\ \\ -� \ , \ \`MBE \���i �/ bR � 110' DRAINAGE, v �+ + \-°/ POND 1 MAINTENANCE AND Y O / \ \ \ \ UTILITY EASEMENT _ + ./+ V / FUTURE DEVELOPMENT \ \ OPEN SPACE + i + \ �� I ' / / p/ /C'q�FN // / / SIT PARCEL#:84041 \ V - - + ; ; y \ RiV Fy / �� / / / q�F�R/�cF / �,� / \ \ PA &TCA--31_--- \ - I �g g / PIN 3nwa -__� + OPEN �/ �V i� ��� �� +� O / SPACE PR \ \ \° \ / 30' UTILITY ESMT. I + + + + `+%�+ \ O // , �co �°j N6 . \ // TO \ \ IIg < ` \ Oar SECOND ACCESS DRIVE TO BE \ 2S� CONSTRUCTED AS S 88°24'59" E 313.43' 65' DRAINAGE \ \ �co SOS' THE HIGHWAY I ° \ / \ POND 2 `. \ \ ,\ F- ESMT. \ ACCESS ROAD IS POOL HOUSE ,20' SETBACK I �/ / O ^ \ CONSTRUCTED. 0 OR� \ �OMOF SS0O r �\ \ / I013 n Cps A + �I, OPEN I � $07�� \ / ry 'c O \ \ + SPACE i I o w 23? ,� _ a ° \� /SNP - - - - \h,. \ +I `_ OPEN SPACE � O a • a - UFO \ &TCA N PARCEL#: 0 PARCEL#: 84041 uNj' ° °' a .��'` � • .. � a - / � F-.., + � � 40' SETBACK / WETLANDS ° I I m 84048 �� M FUTURE DEVELOPMENT M ". MAIL KIOSK '' / (TYP.) \� w POOL (SEE ARCH PLANS 'atl / I COMMUNICATIONS o FOR DETAILS) / \ EASEMENT AREA DB N a w� 2��\ / O OPEN ` v +1� + \\`°�CD 4646 PG 1527 ^Qj 0��� �P 0 o ti g i ` \ \ ` SPACE \ �, t� OPEN v j 15' LANDSCAPE p�\ gO OPEN �W z SPACE SPACE / I ` COS \, - BUFFER (TYP.) CLUBHOUSE- /. �I N66 L ----"� \\ WETLANDS � J 0 15' LANDSCAPE 6 3508 V O,Q/� A (TYP.) �� (6 qj i BUFFER (TYP.) o �� �- N 237 F� O2 0 0 _ _ - _ 20' SETBACK / �6 _ _ Q 30 DRAINAGE 7��ii ♦ \ C� UTILITY EASEMENT -MAINTENANCEAND ,�srg, \\ w ,' -- - I v / / ti6x 20' X 250' SDE 20' X 250' SDE / 10 \ \ �p / PARCEL#: PARCEL#: o� I �i --- - \ 84044 / �ZOS 84038 a `\ / PARCEL#: o I / _ \. ,/\ 1 84043 / z 30, - - _ 6'Q, / / PARCEL#: / g 79°3955 W C/L - R/W sao4o / i 66�,86' 69, /EXISTING 18' ROAD S 86037'00" W N 81044'34" W ,C7,/ �T�D,Q� / EP-EP R- 400.47 R= 400.47' T� ,Q -9p S 68°00' " V\/ CH= 129.45 CH= 32.70' OW 7 O ], 62' /2 I C) � \ PARCEL#: _ 1 84033 0o m N I W PARCEL#: ti 11-1 84041 `S� 4� 55 / EXISTING PARCEL#: I R= 400.47' DRIVEWA 127289 I CH= 129.45' EXISTING 20' ROAD (TYP.) PARCEL#: � �" EP-EP SIDEWALK INSTALLATION AND INSPECTION: 1. PRIOR TO INSTALLATION OF PUBLIC SIDEWALK AND/OR DRIVEWAYS WHICH ARE TO BE PERMITTED THROUGH DEVELOPMENT SERVICES (BUILDING INSPECTIONS) CALL 336-373-2155. 2. AFTERWARDS, CONTACT ROADWAY INSPECTIONS AT 336-373-2336 WHEN SIDEWALK AND/OR DRIVEWAYS ARE READY FOR INSTALLATION. PLUMBING PERMIT NOTICE: PLUMBING INSPECTION REQUIRED ON 3" WATER SERVICE AND 6" SEWER SERVICE. CALL DEVELOPMENT SERVICES AT (336) 373-2155 FOR PERMIT. EXISTING WATER METER REMOVAL: COORDINATE EXISTING WATER METER REMOVAL WITH THE CITY OF GREENSBORO METER SHOP. (336) 373-2071 84026 DUMPSTER: PLEASE CALL AT LEAST 6 WEEKS PRIOR FOR DUMPSTER PLACEMENT. ALL NEW DUMPSTERS PAD CONSTRUCTIONS MUST MEET THE CITY OF GREENSBORO SPECIFICATIONS FOR SINGLE AND DOUBLE PADS/ENCLOSURES (HTTP://WWW.GREENSBORO-NC.GOV/INDEX.ASPX?PAGE=522). SINGLE DUMPSTER PADS/ENCLOSURES SHOULD BE 10 FEET WIDE, IF THE DUMPSTER PAD IS GOING TO HAVE AN ENCLOSURE, THEN THE OPENING/ENTRANCE TO THE ENCLOSURE SHOULD BE 12 FEET WIDE, 2 FEET WIDER THAN THE PAD. DOUBLE DUMPSTER PADS SHOULD BE 20 FEET WIDE, IF THE DUMPSTER PAD IS GOING TO HAVE AN ENCLOSURE, THEN THE OPENING/ENTRANCE TO ENCLOSURE SHOULD BE 22 FEET WIDE, 2 FEET WIDER THAN THE PAD. ALWAYS CALL TO SCHEDULE A SITE VISIT PRIOR TO THE POURING OF CONCRETE FOR ANY NEW DUMPSTER PAD. JAMES JORDAN FIELD OPERATIONS, SOLID WASTE DIVISION 336-373-2256. JAM ES.JORDAN@GREENSBORO-NC.GOV" zp Y / PARCEL#: 84046 SUBGRADE COMPACTED TO A MINIMUM 98% STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D 698); REFER TO SOILS REPORT IF AVAILABLE. i \ 0 co i i i i i \% FUTURE NCDOT R/W WIDTH VARIES TOTAL AREA: 13.85 AC 3" S9.56 7" ABC 24' DRIVE AISLE PAVEMENT SECTION (HEAVY DUTY) N.T.S. SUBGRADE COMPACTED TO A MINIMUM 98% STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D 698); REFER TO SOILS REPORT IF AVAILABLE. 2" S9.5B 6" ABC PARKING SPACE PAVEMENT SECTION (LIGHT DUTY) N.T.S. E DATA RCEL: 84035 :7887697696 GREENS APARTMENT LLC OPERTY ADDRESS: 4717 4733 US HIGHWAY 29 N 8643 PG: 2677 TAL SITE AREA: 23.82 ACRES ,HT OF WAY DEDICATION: 2.47 ACRES -ECTIVE SITE AREA: 21.35 ACRES VING: STING ZONING: CD RM-18 ID USE: MULTI-FAMILY/DUPLEX ✓ELOPMENT STANDARDS: E ZONING NOTES FOR SETBACK INFORMATION) I. BUILDING SEPARATION: 10' K. BUILDING HEIGHT ALLOWABLE: 80' K. BUILDING HEIGHT PROPOSED: 44' FAL NO. OF UNITS: 192 gSITY : 192 UNITS / 23.82 AC = 8.06 UNITS/AC LDING COVERAGE: 90.214 SF (8.69%) gSITY REQUIREMENT: )0 SF/DU FOR FIRST 3 DUs THEN 2,420 SF R EVERY ADDITIONAL LOT )UIRED LOT SIZE: 8,500 SF + 457,380 = 465,880 SF (10.70 AC) EA PROVIDED = 15.48 AC EN SPACE .A REQUIRED: 435 SF X 192 UNITS = 83,520 SF (1.92 AC) EA PROVIDED: 538,997 SF (12.37 AC) PARKING REQUIREMENTS AMENITY AREA: 1 PER 25 UNITS 0-1 BEDROOM: 1.25 PER UNIT 2 BEDROOM: 1.5 PER UNIT 3 BEDROOM: 2.0 PER UNIT PHASE 1 HAS 2-36 UNIT BUILDINGS AND 5-24 UNIT BUILDINGS AMENITY AREA: 192 UNITS @ 1 PER 25 UNITS = 8 SPACES I BEDROOM UNITS: 96 UNITS @ 1.25 SPACES PER UNIT= 120 SPACES 2 BEDROOM UNITS: 84 UNITS @ 1.5 SPACES PER UNIT= 126 SPACES 3 BEDROOM UNITS: 12 UNITS @ 2.0 SPACES PER UNIT = 24 SPACES TOTAL PARKING SPACES REQUIRED: 278 SPACES TOTAL PARKING SPACES PROVIDED: 279 SPACES UNIT BREAKDOWN TABLE BUILDING TYPE 1 BEDROOM 2 BEDROOM 3 BEDROOM 24 UNITS 12 12 0 36 UNITS 18 12 6 TOTAL 30 24 6 100 0 50 100 200 400 SCALE 1"=100' Vn LP1 O ro > N LnZ E CD V Ln C � CD m m NC) V) r V 0 �m OvcuZ Lc 00 N -co 3� 3 m V Co 3: 0 J co 00 J w O H pZU)N Q 2 � j z 0 OaU)0 LL zQwm U)�(7) 3:woow W0 (D (D Z V J J � J W U) V) � Z W W F.- W cl) r V Q z J O 0WW< Q m OL U 0z�� JWp LLI 0 O}�Q 0� aUUco PARCEL# PIN OWNER ❑B PG PB PG ZONING LUC 127289 7887-58-5347 GLADYS COBLE FAMILY FARM LLC 7493 1713 R-3 1 84046 7887-68-8902 LARRYWILLIAM WHITE 3425 1690 R-3 1 84041 7887-69-6090 MARVIN L. WOMACK 6496 642 R-3 1 84040 7887-69-5078 APRI L BANKS- SWANSON 6636 2778 R-3 1 84043 7887-69-4184 JAMESA LIVENGOOD 7121 2250 R-3 1 84044 7887-69-3169 DAVID MICHAEL MORRISON 4946 71 62 76 R-3 1 84026 7887-68-5609 KEELEY REALTY GREENSBORO LLC 7493 1713 LI 4 W38 7887-59-7191 JEFFREYALLAN KINTUP 4496 1425 76 166 R-3 1 84107 7888-50-3391 JASON JAKE & MANDY ELAINESWOFFORD 4135 260 14 14 R-3 1 84055 7888-50-7217 HOBERT H & NORA B BURLESON 2717 95 125 150 84098 7888-50-8448 HOBERT H & NORA B BURLESON 4561 606 14 68 R-3 1 84047 7888-71-3155 STATE OF NORTH CAROLI NA 2662 159 PI 3 84048 7887-79-1354 DEPARTMENT OF TRANSPORTATION 8564 2056 HB 3 84033 7887-79-0013 DEPARTMENT OF TRANSPORTATION 8514 577 RS-30 1 84041 7887-59-5463 DALY MANAGEMENT LLC 8556 2901 R-3 1 84041 7887-59-9824 DALY MANAGEMENT LLC 8556 2901 R-3 1 SUBGRADE COMPACTED TO A MINIMUM 98% STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D 698); REFER TO SOILS REPORT IF AVAILABLE. 3" S9.5B 77� 7" ABC 24' DRIVE AISLE PAVEMENT SECTION (HEAVY DUTY) SUBGRADE COMPACTED TO A MINIMUM 98% STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D 698); REFER TO SOILS REPORT IF AVAILABLE. N.T.S. N.T.S. TREE CONSERVATION/RESTORATION AREA: TCA REQUIRED: 10.00% x 23.82 ACRES (1,037,599 SF) = 2.38 (103,673 SF) REFORESTATION RATE: 400 SF PER 2" CALIPER TREE -90,328.897 SF / 400 SF = 225.82 = (226) 2" CALIPER TREES REQUIRED - (226) 2" CALIPER TREES X 400 S.F. = 90,328.897 S.F. TCA PROVIDED: 2.40 AC (104,544 S.F.) TREE CONSERVATION NOTES 1. CONTACT THE PLANNING DIRECTOR TO SCHEDULE A PRE -CONSTRUCTION MEETING BEFORE ANY TREE DISTURBANCE, EXCEPT AS NOTED IN SEC. 30-4-26.3(C)(5)., OCCURS ON THIS SITE. 2. ALL TREE CONSERVATION DEVICES MUST BE INSTALLED BEFORE INSPECTION BY THE PLANNING DIRECTOR AND BEFORE ANY TREE DISTURBANCE ACTIVITIES, EXCEPT AS NOTED IN SEC. 30-4-26.3(C)(5), OCCUR. 3. REMOVAL OF OR DAMAGE TO TREES IN THE TREE CONSERVATION AREA WILL BE SUBJECT TO ALL AVAILABLE REMEDIES AND PENALTIES UNDER THE CITY'S DEVELOPMENT ORDINANCE. 4. NO PARKING, STORAGE, DIRT STOCKPILING, CONCRETE WASHOUT OR ANY OTHER ACTIVITIES IS PERMITTED IIN THE TREE CONSERVATION AREA. UNIT BREAKDOWN TABLE BUILDING TYPE 1 BEDROOM 2 BEDROOM 3 BEDROOM 24 UNITS 12 12 0 36 UNITS 18 12 6 TOTAL j 30 j 24 j 6 LANDSCAPING: 1. PER COG DEVELOPMENT ORDINANCE 30-10-2.5 C: ON LOTS OF RECORD THAT EXISTED PRIOR TO JULY 1, 1992 THAT ARE LESS THAN 55,000 SQUARE FEET IN AREA, NO DEVELOPMENT IS REQUIRED TO LANDSCAPE MORE THAN 15% OF THE SITE. 2. A MINIMUM 5-FOOT WIDE PLANTING YARD WITH A COMBINATION OF VEGETATION AND/OR OPEN DECORATIVE FENCING AT LEAST 2.5 FEET IN HEIGHT AND A MAXIMUM OF 3.5 FEET IN HEIGHT SHALL BE PROVIDED AT OWNER'S DISCRETION 3. STREETSCAPE CANOPY TREES ARE SPREAD OUT WITHIN SITE DUE TO SITE CONSTRAINTS. 4. NO NEW TREES OR THE PROJECTED MATURE CANOPY ALLOWED WITHIN 10, OF EXISTING/PROPOSED WATER AND SEWER. LANDSCAPE BUFFER YARD: PARKING LOT LANDSCAPING: PLANTING YARD TYPE: C PARKING AREA: 1 TREE PER 12 SPACES AVERAGE WIDTH: 15 FT CANOPY TREES LENGTH: 3,880 FT REQUIRED: 24 CANOPY TREES (2 PER 100 FT): PROVIDED: 24 REQUIRED: 78 PROVIDED: 78 UNDERSTORY TREES (3 PER 100 FT): REQUIRED: 117 PROVIDED: 117 SHRUBS (17 PER 100 FT): REQUIRED: 660 PROVIDED: 660 STREET PLANTING YARD: TOTAL LANDSCAPING PROVIDED WIDTH: 10 FT LENGTH: 1,120 FT CANOPY TREES: 125 0 CANOPY TREES (2 PER 100 FT): REQUIRED: 23 UNDERSTORY TREES: 117 PROVIDED: 23 ® SHRUBS (17 PER 100 FT): SHRUBS: 851 REQUIRED: 191 PROVIDED: 191 PLUMBING PERMIT NOTICE: PLUMBING INSPECTION REQUIRED ON 3" WATER SERVICE AND 6" SEWER SERVICE. CALL DEVELOPMENT SERVICES AT (336) 373-2155 FOR PERMIT. EXISTING WATER METER REMOVAL: COORDINATE EXISTING WATER METER REMOVAL WITH THE CITY OF GREENSBORO METER SHOP. (336) 373-2071 SIDEWALK INSTALLATION AND INSPECTION: 1. PRIOR TO INSTALLATION OF PUBLIC SIDEWALK AND/OR DRIVEWAYS WHICH ARE TO BE PERMITTED THROUGH DEVELOPMENT SERVICES (BUILDING INSPECTIONS) CALL 336-373-2155. 2. AFTERWARDS, CONTACT ROADWAY INSPECTIONS AT 336-373-2336 WHEN SIDEWALK AND/OR DRIVEWAYS ARE READY FOR INSTALLATION. DUMPSTER: PLEASE CALL AT LEAST 6 WEEKS PRIOR FOR DUMPSTER PLACEMENT. ALL NEW DUMPSTERS PAD CONSTRUCTIONS MUST MEET THE CITY OF GREENSBORO SPECIFICATIONS FOR SINGLE AND DOUBLE PADS/ENCLOSURES (HTTP://WWW.GREENSBORO-NC.GOV/INDEX.ASPX?PAGE=522). SINGLE DUMPSTER PADS/ENCLOSURES SHOULD BE 10 FEET WIDE, IF THE DUMPSTER PAD IS GOING TO HAVE AN ENCLOSURE, THEN THE OPENING/ENTRANCE TO THE ENCLOSURE SHOULD BE 12 FEET WIDE, 2 FEET WIDER THAN THE PAD. DOUBLE DUMPSTER PADS SHOULD BE 20 FEET WIDE, IF THE DUMPSTER PAD IS GOING TO HAVE AN ENCLOSURE, THEN THE OPENING/ENTRANCE TO ENCLOSURE SHOULD BE 22 FEET WIDE, 2 FEET WIDER THAN THE PAD. ALWAYS CALL TO SCHEDULE A SITE VISIT PRIOR TO THE POURING OF CONCRETE FOR ANY NEW DUMPSTER PAD. JAMES JORDAN FIELD OPERATIONS, SOLID WASTE DIVISION 336-373-2256. JAMES.JORDAN@GREENSBORO-NC.GOV" `� ZONE 2 I a S 88°24'59" E 313.43' POND 2 �`8�e 20' STREAM BUFFER OPEN w N \ / o SPACE F 00 o ZONE 1 BUILDING ENTRANCE/ �`� `\�F, HEIGHT: 22.1' z EXIT (TYP.) / ` �� OMUF 30' STREAM BUFFER I z LK 6'SIDEWA4' IDEWALK OPEN SPACE 13 �� R20' FOC POOL O �65' DRAINAGE i FENCING TO BE HOUSE �� / ESMT. I i APPROX. 5' TOB =3,308 SF � 6' DRIVE AISLE - - OMUF_L PLACED 0.5' INSIDE - � � - CONCRETE AROUND E I x ..f 8' � P\�' � 8'f 8' POOL DECKING \�E - �� I 5' SIDEWALK /ZA OR 40' ° v 13 \� R20' FOC � p vv v � �,a - • 4 DE A � U � \O � �MUF`\ 15' LANDSCAPES PARCEL#: 84041 ° ° v p ° ,•� MAIL KIOSK F 5 ----PROP. 58 LF 4.5' 1 2'cm BUFFER(TYP.) v v ` BUFFER TYP. RETAINING WALL 20' DE F` i' ` `�\ FUTURE DEVELOPMEN p (SEE ARCH PLANS I 140' FOR DETAILS) PROP. CURB RAMP Po / / WETLANDS '� ` �� U COG STD 418 (TYP.) ENTRANCE/ (TYP.) O m v PROP. WHEEL I �' EXIT (TYP.) t� o PROP. CURB RAMP w 0� ° STOP (TYP.) ��d ✓ OPEN SPACE 110' DRAINAGE, m o I M v 70 POOL PROP. CURB RAMP OR\��El \ COG STD 418 (TYP.) BUILDING & TCA \� ` MAINTENANCE AND w o -9,800 SF op I vGP per\ 24' FC-FC HEIGHT: 43.8' COG STD 418 (TYP.) gN�P�E \� UTILITY EASEMENT OM P 3 STORY - 24 UNIT R20' FOC APARTMENT BLDG OPEN (8 UNITS/FLOOR) SPACE z DE --`%40,10,083 SF z w OPEN 20 / 3 9T �, SPACE I �FT@ Ck �� OG PROP. 242 LF 12' 40' I / / �2RETAINING WALL PARCEL#: 84038 PARCEL#: 127289 DEAD END STREET PER COG STD. 502-A DETAILS & SHEET 11 FOR PROPOSED GRADING) �S BUILDING HEIGHT:43.6' V I \� DOUBLE DUMPSTER PAD WITH GATES & SCREEN ENCLOSURE COG STD 1001, 1003 & 1008 (SEE DETAIL SHEET) / PARCEL#: 84046 50 0 25 50 / 100 200 . 1_1Roimmel SITE PLAN NOTES: 1. ALL CONSTRUCTION SHALL CONFORM TO THE LATEST CITY OF GREENSBORO, GUILFORD COUNTY PLANNING & EROSION CONTROL, NCDEQ AND NCDOT STANDARDS AND SPECIFICATIONS. 2. ALL DIMENSIONS SHOWN ON SITE PLAN ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. 3. SOIL UNDER BUILDINGS AND PAVED AREAS SHALL BE COMPACTED TO STANDARD PROCTOR MAXIMUM DRY DENSITY AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER AND SHALL CONFORM TO CITY OF GREENSBORO REQUIREMENTS WITHIN PUBLIC RIGHT OF WAY. 4. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR TO CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811 ". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND/OR RELOCATION OF ALL EXISTING UTILITIES IN COORDINATION WITH THE APPROPRIATE UTILITY, AGENCY, OR COMPANY. CONTRACTOR TO COORDINATE ACTIVITIES WITH UTILITY COMPANIES INVOLVED IN ANY RELATED RELOCATION (I.E. POWER POLES, TELEPHONE PEDESTALS, WATER METERS, ETC.). 6. EXISTING UTILITIES SHOWN ARE BASED ON FIELD SURVEYS AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY CONDITIONS PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND THE PLANS SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 7. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 11 o z 0 co VICINITY MAP 1 "=2000' SITE DATA PARCEL: 84035 PIN:7887697696 OWNER: GREENS APARTMENT LLC PROPERTY ADDRESS: 4717 4733 US HIGHWAY 29 N DB: 8643 PG: 2677 TOTAL SITE AREA: 23.82 ACRES RIGHT OF WAY DEDICATION: 2.47 ACRES EFFECTIVE SITE AREA: 21.35 ACRES ZONING: EXISTING ZONING: CD RM-18 LAND USE: MULTI-FAMILY/DUPLEX DEVELOPMENT STANDARDS: (SEE ZONING NOTES FOR SETBACK INFORMATION) MIN. BUILDING SEPARATION: 10' MAX. BUILDING HEIGHT ALLOWABLE: 80' MAX. BUILDING HEIGHT PROPOSED: 44' '0 0 m�11 Al LN TOTAL NO. OF UNITS: 192 DENSITY: 192 UNITS / 23.82 AC = 8.06 UNITS/AC BUILDING COVERAGE: 90,214 SF (8.69%) DENSITY REQUIREMENT: 8,500 SF/DU FOR FIRST 3 DUs THEN 2,420 SF FOR EVERY ADDITIONAL LOT REQUIRED LOT SIZE: 8,500 SF + 457,380 = 465,880 SF (10.70 AC) AREA PROVIDED = 15.48 AC OPEN SPACE AREA REQUIRED: 435 SF X 192 UNITS = 83,520 SF (1.92 AC) AREA PROVIDED: 538,997 SF (12.37 AC) PARKING REQUIREMENTS AMENITY AREA: 1 PER 25 UNITS 0-1 BEDROOM: 1.25 PER UNIT 2 BEDROOM: 1.5 PER UNIT 3 BEDROOM: 2.0 PER UNIT PHASE 1 HAS 2-36 UNIT BUILDINGS AND 5-24 UNIT BUILDINGS AMENITY AREA: 192 UNITS @ 1 PER 25 UNITS = 8 SPACES I BEDROOM UNITS: 96 UNITS @ 1.25 SPACES PER UNIT= 120 SPACES 2 BEDROOM UNITS: 84 UNITS @ 1.5 SPACES PER UNIT= 126 SPACES 3 BEDROOM UNITS: 12 UNITS @ 2.0 SPACES PER UNIT = 24 SPACES TOTAL PARKING SPACES REQUIRED: 278 SPACES TOTAL PARKING SPACES PROVIDED: 279 SPACES ZONING NOTES: 1. PERMITTED USES SHALL BE LIMITED TO ALL USES PERMITTED IN THE RM-18 ZONING DISTRICT EXCEPT LAND CLEARING AND INERT DEBRIS LANDFILLS, MINOR (ACCESSORY USE). 2. THE MINIMUM SEPARATION DISTANCE FROM MULTI -FAMILY Vn LP1 O r''1 > N V LnZ E "= O � p v V CD C Ln �.> CD N C) V) V •�� pO vNZ w H co a) -co 3� s= 3 m V co 3rn n To Uo J M pp J w O H O U Z CIA H w H U w Z W0 Oaco0 zQwm = U(7) �zQz w�w zwwU)w LLI r � V (O v ' 1 J J LU V ! ~ Z U) W W 0 Lu J r � V WZ Q Q J O 0WW< Q m OL U 0ZZ� JW00 wO�ui 0}Z)Q 0� w aUUU GENERAL NOTES: BUILDINGS TO ADJACENT PARKING OR DRIVE AISLE IS 10 . 3. MAXIMUM ALLOWED BUILDING LENGTH IS 250'. 1. AREA DETERMINED UTILIZING COMPUTER SOFTWARE. 4. ZONING INFORMATION: 2. GRID TIE INFORMATION BASED ON MONUMENTATION AND DATUM AS SHOWN, STREET SETBACK: 20' ALL DISTANCES ARE GROUND DISTANCES (US FEET) UNLESS OTHERWISE SIDE STREET SETBACK: 15' SHOWN. THOROUGHFARE SETBACK: 35' 3. NO NGS MONUMENTS WERE RECOVERED WITHIN 2000' OF THIS PROPERTY. SIDE AND REAR SETBACKS: 4. NO SUBSURFACE INVESTIGATION PERFORMED BY FLEMING ENGINEERING, INC. ABUTTING R-DISTRICTS OR SINGLE FAMILY DWELLINGS 5. UTILITY LOCATION WORK SHOWN HEREON WAS DERIVED BY ABOVE GROUND SIDE: 20', REAR: 40' INDICATORS ONLY, UNLESS OTHERWISE NOTED. ABUTTING ANY OTHER DISTRICT: 6. THIS PROPERTY IS SUBJECT TO ANY EASEMENTS, AGREEMENTS OR RIGHTS OF SIDE: 15', REAR: 20' WAY RECORDED PRIOR TO THE DATE OF THIS MAP WHICH WERE NOT VISIBLE AT THE TIME OF INSPECTION. 7. THE SURVEYOR HAS NOT PERFORMED A TITLE INVESTIGATION ON THIS PROPERTY, THEREFORE, THIS MAP IS SUBJECT TO ANY AND ALL FACTS AN TRANSPORTATION NOTES: ACCURATE TITLE INVESTIGATION MAY DISCLOSE. 1. NO PLANTINGS OR OTHER OBJECTS SHALL BE WITHIN SIGHT TRIANGLES 8. THIS MAP DOES NOT MEET G.S. 47-30 AND IS NOT FOR RECORDING OR AT A HEIGHT BETWEEN 2.5' AND 10' (CANOPY) ABOVE THE FINISHED CONVEYANCE. GRADE OF THE PROPOSED DRIVEWAY OR WITHIN ANY STREET 9. THE CLASSIFICATION OF THIS SURVEY IS NORTH CAROLINA CLASS A. INTERSECTION SIGHT TRIANGLE. 10. HORIZONTAL DATUM: NAD83(2011). 2. NO VEHICLES ACCESSING THIS SITE SHALL BACK TO OR FROM THE 11. ANY SIGNS TO BE PLACED ON SITE MUST BE SUBMITTED SEPARATELY FOR PUBLIC RIGHT OF WAY. ZONING REVIEW. 3. NO VEHICLES ACCESSING THIS SITE SHALL QUEUE IN THE PUBLIC RIGHT 12. PATIO/OVER HANG AREA IS GOING TO BE AN OPEN AREA THAT SHARES THE OF WAY. SAME ROOF AS THE OFFICE BUILDING. 4. REFERENCE COG STD. 416-A FOR ACCEPTABLE DRIVEWAY GRADES 13. ANY STRUCTURE TO BE REMOVED SHALL REQUIRE A SEPARATE DEMOLITION (SEE SHEET 26 OF 29). PERMIT FROM THE BUILDING INSPECTIONS DEPARTMENT. 5. DRIVEAY TO BE CONSTRUCTED PER COG 416-B (SEE SHEET 26 OF 29). 14. MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED THROUGHOUT EXIT 6. SIDEWALK TO BE CONSTRUCTED PER COG 418-A (SEE SHEET 26 OF 29). DISCHARGES IN ACCORDANCE WITH NCBC. 7. REPAIR/REPLACE/INSTALL ANY DAMAGED OR MISSING CURB AND 15. ALL EXISTING AND PROPOSED OVERHEAD POWER LINES ARE INDICATED ON GUTTER ALONG PROPERTY FRONTAGE PER 30" COG 501. THE SITE PLAN. IF NO OVERHEAD POWER LINES ARE INDICATED, THERE SHALL 8. REPAIR/REPLACE/INSTALL ANY DAMAGED OR MISSING SIDEWALK ALONG BE NONE WITHIN 10 FEET OF THE PROPERTY LIMITS. PROPERTY FRONTAGE PER COG 418-A. 16. HANDICAP SIGNAGE SHALL BE INSTALLED ON FACE OF BUILDING. 9. PRIOR TO INSTALLATION OF PUBLIC SIDEWALK AND/OR DRIVEWAYS CONTRACTOR TO COORDINATE LOCATION WITH OWNER AND ARCHITECTURAL WHICH ARE TO BE PERMITTED THROUGH DEVELOPMENT SERVICES PLANS. (BUILDING INSPECTIONS) CALL 336-373-2155. AFTERWARDS, CONTACT ROADWAY INSPECTIONS AT 336-373-2336 WHEN SIDEWALK STORMWATER MANAGEMENT INFORMATION AND/OR DRIVEWAYS ARE READY FOR INSTALLATION. 10. MAINTAIN A 5' UTILITY CLARENCE AT DRIVES. 1. THIS PROPERTY IS LOCATED WITHIN FLOOD ZONE X (ZONE X AREAS ARE 11. PROVIDE MINIMUM 4' SIDEWALK WIDTH CLEARANCE AROUND ALL DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN) AREA ABOVE GROUND UTILITIES. AS INDICATED ON THE FLOOD INSURANCE RATE MAP (FIRM) MAP NUMBER 3710788700J, EFFECTIVE DATE JUNE 18TH, 2007. 2. BUILT UPON AREA (BUA) TOTAL AREA: 930,079 SF 21.35 ACRES UTILITY NOTES: EXISTING BUA: 103,237 SF 2.37 ACRES (11.10%) 1. ALL CONSTRUCTION TO COG/NCDEQ STDS. EXISTING BUA TO BE REMOVED: 87,556 SF 2.01 ACRES (9.40%) 2. TERMINATE EXISTING, UNUSED WATER/SEWER TO THE MAIN TO COG STD. PROPOSED BUILT UPON AREA: 280,091 SF 6.43 ACRES (30.12%) 3. METER, BACKFLOW PREVENTER AND ENCLOSURES TO COG STD. TOTAL BUA: 295,772 SF 6.79 ACRES (31.80%) 4. ALL STANDARD NCDEQ/COG REQUIRED UTILITY SEPARATIONS MUST BE PROVIDED. 3. ALL NECESSARY APPROVALS HAVE BEEN (WILL BE) OBTAINED FROM NCDEQ 5. CONTACT JAY GUFFEY (336-373-7779) FOR A LIST OF APPROVED AND U.S. ARMY CORPS OF ENGINEERS FOR ANY WETLAND DISTURBANCE CONTRACTORS TO MAKE TAPS ON REHABILITATED MAINS. AND STREAM CROSSING/DISTURBANCE WHERE APPLICABLE. 6. COORDINATE METER REMOVAL WITH COG METER SHOP. #336-373-2071 7. THERE IS NOT A FIRE PUMP ASSOCIATED WITH THIS PROJECT. 4. ENGINEER'S CERTIFICATION OF STORMWATER QUANTITY CONTROL: THE NET INCREASE IN BUILT -UPON AREA IS GREATER THAN 400 SQUARE FEET, THEREFORE, THIS DEVELOPMENT IS SUBJECT TO 30-12-7.2(B)(7)(b) OF THE GREENSBORO LAND DEVELOPMENT ORDINANCE. SITE LIGHTING NOTE 5. ALL PUBLIC STORM SEWER MUST BE INSTALLED PER NCDOT 1. THE OUTDOOR SITE LIGHTING SHALL COMPLY WITH CITY OF SPECIFICATIONS. GREENSBORO GENERAL DEVELOPMENT STANDARD 30-9-6. 6. PRIOR TO PUBLIC STORM SEWER INSTALLATION, CONTACT CHAD MANESS AT (336) 373-2336 TO SCHEDULE THE ASSIGNMENT OF AN INSPECTOR. w a 42 Q d 0 a zaaaaaaw DRAWN BY: LSM CHECKED BY: BCS DATE: 04/11 /2023 PROJECT NO.: 02031.001 REF. NO.: - SCALE: 1" = 50' `````"�uuwunrnggrr CARObib C tTIN �N SHEET 5 O F 29 PARCEL# PIN OWNER ❑B PG PB PG ZONING LUC LANDSCAPING: TREE CONSERVATION/RESTORATION AREA: TRANSPORTATION NOTES: EASEMENT OF 127289 7887-58-5347 GLADYS COBLE FAMILY FARM LLC 7493 1713 R-3 1 NOTES: 1. COG ORDINANCE C: ON OF TCA REQUIRED: 10.00% x 23.82 ACRES (1,037,599 SF) = 2.38 (103,673 SF) 1. NO PLANTINGS OR OTHER OBJECTS SHALL BE WITHIN SIGHT TRIANGLES INGRESS, EGRESS PER DEVELOPMENT 30-10-2.5 LOTS RECORD THAT EXISTED PRIOR REFORESTATION RATE: 400 SF PER 2" CALIPER TREE AT A HEIGHT BETWEEN 25AND 10' (CANOPY) ABOVE THE FINISHED 84046 7887-68-8902 LARRY WI LLIAM WHITE 3425 1690 R-3 1 TO JULY 1, 1992 THAT ARE LESS THAN 55,000 SQUARE FEET IN AREA, NO DEVELOPMENT IS -90,328.897 SF / 400 SF = 225.82 = (226) 2" CALIPER TREES REQUIRED GRADE OF THE PROPOSED DRIVEWAY OR WITHIN ANY STREET \ AND REGRESS D.B. 84041 7887-69-5090 MARV I N L. WOMACK 6496 642 R-3 1 REQUIRED TO LANDSCAPE MORE THAN 15% OF THE SITE. - (226) 2" CALIPER TREES X 400 S.F. = 90,328.897 S.F. INTERSECTION SIGHT TRIANGLE. 2103 PG. 615 (30' ON 2. A MINIMUM 5-FOOT WIDE PLANTING YARD WITH A COMBINATION OF VEGETATION AND/OR TCA PROVIDED: 2.40 AC (104,544 S.F.) 2. NO VEHICLES ACCESSING THIS SITE SHALL BACK TO OR FROM THE EACH SIDE OF 84040 7887-69-5078 APRI L BANKS- 5WAN50N 6636 2778 R-3 1 OPEN DECORATIVE FENCING AT LEAST 2.5 FEET IN HEIGHT AND A MAXIMUM OF 3.5 FEET IN PUBLIC RIGHT OF WAY. \ $4043 7887 69 41$4 DAMES A LIVENGOO❑ 7121 2250 R-3 1 HEIGHT SHALL BE PROVIDED AT OWNER'S DISCRETION TREE CONSERVATION NOTES : 3. NO VEHICLES ACCESSING THIS SITE SHALL QUEUE IN THE PUBLIC RIGHT PROPERTY LINE ) 3. STREETSCAPE CANOPY TREES ARE SPREAD OUT WITHIN SITE DUE TO SITE CONSTRAINTS. OF WAY. 84044 84026 7887-69-3169 7887-68-5609 DAVID MICHAEL MORRISON KEELEY REALTY GREENSBORO LLC 4946 7493 71 62 1713 76 R-3 LI 1 4 4. NO NEW TREES OR THE PROJECTED MATURE CANOPY ALLOWED WITHIN 10' OF EXISTING/PROPOSED WATER AND SEWER. 1. CONTACT THE PLANNING DIRECTOR TO SCHEDULE A PRE MEETING BEFORE ANY TREE DISTURBANCE, 4. REFERENCE COG STD. 416-A FOR ACCEPTABLE DRIVEWAY GRADES (SEE SHEET 26 OF 29). $403$ 7887 59 7191 JEFFREY ALLAN KINTUP 4496 1425 76 166 R-3 1 -CONSTRUCTION EXCEPT AS NOTED IN SEC. 30-4-26.3(C)(5). OCCURS ON THIS SITE. 5. DRIVEAY TO BE CONSTRUCTED PER COG 416-B (SEE SHEET 26 OF 29). 84107 7888-50-3391 JASON JAKE & MANDY ELAINESWOFFORD 4135 260 14 14 R-3 1 84055 7888-50-7217 HOBERT H & NORA B BURLESON 2717 95 125 15❑ 84098 7888-50-8448 HOBERT H & NORA B BURLESON 4561 606 14 68 R-3 1 84047 7888-71-3155 STATE OF NORTH CAROLI NA 2662 159 PI 3 84048 7887-79-1354 DEPARTMENT OF TRANSPORTATION 8564 2056 HB 3 84033 7887-79-0013 DEPARTMENT OF TRANSPORTATION 8514 577 RS-30 1 84041 7887-59-5463 DALY MANAGEMENT LLC 8556 2901 R-3 1 84041 7887-59-9824 DALY MANAGEMENT LLC 8556 2901 R-3 1 DUMPSTER: PLEASE CALL AT LEAST 6 WEEKS PRIOR FOR DUMPSTER PLACEMENT. ALL NEW DUMPSTERS PAD CONSTRUCTIONS MUST MEET THE CITY OF GREENSBORO SPECIFICATIONS FOR SINGLE AND DOUBLE PADS/ENCLOSURES (HTTP://WWW.GREENSBORO-NC.GOV/INDEX.ASPX?PAGE=522). SINGLE DUMPSTER PADS/ENCLOSURES SHOULD BE 10 FEET WIDE, IF THE DUMPSTER PAD IS GOING TO HAVE AN ENCLOSURE, THEN THE OPENING/ENTRANCE TO THE ENCLOSURE SHOULD BE 12 FEET WIDE, 2 FEET WIDER THAN THE PAD. DOUBLE DUMPSTER PADS SHOULD BE 20 FEET WIDE, IF THE DUMPSTER PAD IS GOING TO HAVE AN ENCLOSURE, THEN THE OPENING/ENTRANCE TO ENCLOSURE SHOULD BE 22 FEET WIDE, 2 FEET WIDER THAN THE PAD. ALWAYS CALL TO SCHEDULE A SITE VISIT PRIOR TO THE POURING OF CONCRETE FOR ANY NEW DUMPSTER PAD DAMES JORDAN FIELD OPERATIONS SOLID WASTE DIVISION 336-373-2256 6. SIDEWALK TO BE CONSTRUCTED PER COG 418-A (SEE SHEET 26 OF 29). 2. ALL TREE CONSERVATION DEVICES MUST BE INSTALLED BEFORE 7. REPAIR/REPLACE/INSTALL ANY DAMAGED OR MISSING CURB AND INSPECTION BY THE PLANNING DIRECTOR AND BEFORE ANY TREE GUTTER ALONG PROPERTY FRONTAGE PER 30" COG 501. �� `SS9°7j DISTURBANCE ACTIVITIES, EXCEPT AS NOTED IN SEC. 30-4-26.3(C)(5), 8. REPAIR/REPLACE/INSTALL ANY DAMAGED OR MISSING SIDEWALK ALONG / 7q., OCCUR. PROPERTY FRONTAGE PER COG 418-A. / 2 9. PRIOR TO INSTALLATION OF PUBLIC SIDEWALK AND/OR DRIVEWAYS / 3. REMOVAL OF OR DAMAGE TO TREES IN THE TREE CONSERVATION AREA WHICH ARE TO BE PERMITTED THROUGH DEVELOPMENT SERVICES °>� \IV WILL BE SUBJECT TO ALL AVAILABLE REMEDIES AND PENALTIES UNDER (BUILDING INSPECTIONS) CALL 336-373-2155. AFTERWARDS, Qv THE CITY'S DEVELOPMENT ORDINANCE. CONTACT ROADWAY INSPECTIONS AT 336-373-2336 WHEN SIDEWALK AND/OR DRIVEWAYS ARE READY FOR INSTALLATION. �C 4. NO PARKING, STORAGE, DIRT STOCKPILING, CONCRETE WASHOUT OR 10. MAINTAIN A 5' UTILITY CLARENCE AT DRIVES. p EXISTING 30' ANY OTHER ACTIVITIES IS PERMITTED IIN THE TREE CONSERVATION 11. PROVIDE MINIMUM 4' SIDEWALK WIDTH CLEARANCE AROUND ALL �o / UTILITY ESMT. AREA. ABOVE GROUND UTILITIES. (TO BE REMOVED) / 7 / 20' LANDSCAPE BUFFER P P OPEN S 9°21'02" E 124.25' / SPACE JAMES.JORDAN@GREENSBORO-NC.GOV" SUBGRADE COMPACTED TO A MINIMUM 98% STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D 698); REFER TO SOILS REPORT IF AVAILABLE. SUBGRADE COMPACTED TO A MINIMUM 98% STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D 698); REFER TO SOILS REPORT IF AVAILABLE. 3" S9.513 2" S9.513 7" ABC 6" ABC 24' DRIVE AISLE PAVEMENT SECTION (HEAVY DUTY) PARKING SPACE PAVEMENT SECTION (LIGHT DUTY) N.T.S. N.T.S. SS83 \` S>6- OPEN SPACE �wo , rT� yAJ � , POND 1 vF DMUE OVER AND 15' AROUND WET POND o�G c m i �i i 1 1D o0 � m m L--- DK OPEN SPACE EXISTING 20' �^ I DRAINAGE ESMT. TIE TO EX. SSMH / I RIM ELEV. 769.32 co 1 / / N o �a IW BUILDING - "' HEIGHT: 43.8' 1 X l \ �1 00 ENTRANCE/ EXIT (TYP.) / 000,/ 07 / 3 STORY - 24 UNIT / APARTMENT BLDG / \ / (8 UNITS/FLOOR) / A/ / 10,083 SF 7� BUILDING HEIGHT: 43.8' PROP. CURB RAMP f 30 COG STD 418 (TYP.) / ENTRANCE/ EXIT (TYP.) PROP. WHEEL / \ STOP (TYP.) O \ Y- 3STORY-24UNIT0000 APARTMENT BLDG �kaP\SSE N / (8 UNITS/FLOOR) 18 BUILDING 10,083 SF PLC 2`' 0��� HEIGHT: 43.8' PROP. CURB RAMP PARCEL#: 84047 /ENTRANCE/ 3� `COG STD 418 (TYP.) / EXIT (TYP.) // 5 PROP. WHEEL ° FCFG 0000/ O STOP (TYP.) a ° O ' 13 3 STORY - 24 UNIT000- ✓ , �� / / / / /APARTMENT BLDG (8 UNITS/FLOOR) / 10,083 SF BUILDING i TRIPLE DUMPSTER / ��� ����F l�A j 15 L� PAD WITH GATES & / 000 HEIGHT:43.6' PROP. CURB RAMP /R5' (TYP.) R��EP.�Q3� / SCREEN ENCLOSURE /� COG STD 418 (TYP.) 15 �PQ��S ° _ COG STD 1001, 1003 & 1008 / ����� ENTRANCE/ �/ EXIT (TYP.) PROP. WHEEL (SEE DETAIL SHEET) \� / STOP (TYP.) O .s ® Fa i R��� �i 3 STORY - 36 UNIT ��P�� 11 25 O OPEN �J APARTMENT BLDG 6 SRO SPACE % / (12 UNITS/FLOOR) 11 PROP. CURB RAMPCOG STD 418 (TYP.) 15,379 SF 13 / R20' FOC 98' EXISTING R/W - C/L% (WIDTH VARIES) w o PROP. CURB RAMP 24" CURB AND 125' FUTURE NCDOT RAN 0 ��Q PAS GUTTER PER (WIDTH VARIES) COG STD 418 (TYP.) COG STD 501 PROP. CURB RAMP 'z'. ( ) q/ TYP.% v> P\ R WHEEL / 10 / COG STD 418 (TYP.) / / `� �-7STOP (TYP.) `� 13 PAS\ $ a r 24' FC-FC Yi 2 E OPEN SITE LIGHTING NOTE SPACE // �gTFOyp�gC o0 1. THE OUTDOOR SITE LIGHTING SHALL COMPLY WITH CITY OF PROL / �� 0�� / / GREENSBORO GENERAL DEVELOPMENT STANDARD 30-9-6. /��P (TYP.)PROP. 265 LF 18' 16/� STOP RETAINING WALL Ell p \ V / ` ZONING NOTES: / PROP. CURB RAMP m� \ ^ / / 1. PERMITTED USES SHALL BE LIMITED TO ALL USES PERMITTED PROP. CURB RAMP \ Q3 COG STD 418 (TYP.) �� S1 ^ IN THE RM-18 ZONING DISTRICT EXCEPT LAND CLEARING AND COG STD 418 (TYP.) P\g\� 3 STORY - 24 UNIT ryV h�INERT DEBRIS LANDFILLS, MINOR (ACCESSORY USE). G ENTRANCE/ APARTMENT BLDG 30' DRIVEWAY / 2. THE MINIMUM SEPARATION DISTANCE FROM MULTI -FAMILY / \)� R20' FOC 2 O \• �� (8 UNITS/FLOOR) \ �, NS = RADIUS (TYP.) BUILDINGS TO ADJACENT PARKING OR DRIVE AISLE IS 10'. p� EXIT (TYP.) 10,083 SF co 90 / 3. MAXIMUM ALLOWED BUILDING LENGTH IS 250'. R5' (TYP.) $ 4. ZONING INFORMATION: SN �� STREET SETBACK: SIDE STREET SETBACK: 15' IQEz \ THOROUGHFARE SETBACK: 35' \ & TCA �2i �� pFz�� PROP. CURB RAMP I i COG STD 418 (TYP.) ZONE 2 I 20' STREAM BUFFER OPEN i SPACE G � ZONE 1 H2O ` / ` 1) 30' STREAM BUFFER I `OMU C/L OF CREEK \ 65' DRAINAGE ESMT. i APPROX. 5' TOB \ \ IT\ 20' ACCESS & MAINTENANCE I EASEMENT FOR WET POND 15' LANDSCAPE G BUFFER (TYP.) OPEN �o � Q I SPACE WETLANDS \ 00 (TYP.) w �\ 110' DRAINAGE, MAINTENANCE AND 3 STORY - 24 UNIT OPEN UTILITY EASEMENT &TCA APARTMENT BLDG (8 UNITS/FLOOR) 10,083 SF PARCEL#: 84048 UNIT BREAKDOWN TABLE BUILDING TYPE 1 BEDROOM 2 BEDROOM 3 BEDROOM 24 UNITS 12 12 0 36 UNITS 18 12 6 TOTAL 30 24 6 BUILDING \ \ HEIGHT: 43.8' m \ \ o� ry 6S° \ 980` y„ , 232, � ` / co LEASE SITE D.B. 4646 PG. 1527 20' TELEPHONE & UTILITY EASEMENT D.B. 4646 PG. 1527 h^ 0 hM h 0 co SECOND ACCESS DRIVE TO BE CONSTRUCTED AS THE HIGHWAY ACCESS ROAD IS CONSTRUCTED. 20' ACCESS & UTILITY to MAINTENANCE EASEMENT o DB. 4646 PG. 1527 ORIGINAL o LEASE FROM GEORGE E. GREEN rev J R. 0 ��. o 50 0 25 50 100 200 ^ h -c� ro SCALE 1 "=50' SIDE AND REAR SETBACKS: ABUTTING R-DISTRICTS OR SINGLE FAMILY DWELLINGS SIDE: 20', REAR: 40' ABUTTING ANY OTHER DISTRICT: SIDE: 15', REAR: 20' STORMWATER MANAGEMENT INFORMATION 1. THIS PROPERTY IS LOCATED WITHIN FLOOD ZONE X (ZONE X AREAS ARE DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN) AREA AS INDICATED ON THE FLOOD INSURANCE RATE MAP (FIRM) MAP NUMBER 3710788700J, EFFECTIVE DATE JUNE 18TH, 2007. 2. BUILT UPON AREA (BUA) TOTAL AREA: 930,079 SF 21.35 ACRES EXISTING BUA: 103,237 SF 2.37 ACRES (11.10%) EXISTING BUA TO BE REMOVED: 87,556 SF 2.01 ACRES (9.40%) PROPOSED BUILT UPON AREA: 280,091 SF 6.43 ACRES (30.12%) TOTAL BUA: 295,772 SF 6.79 ACRES (31.80%) 3. ALL NECESSARY APPROVALS HAVE BEEN (WILL BE) OBTAINED FROM NCDEQ AND U.S. ARMY CORPS OF ENGINEERS FOR ANY WETLAND DISTURBANCE AND STREAM CROSSING/DISTURBANCE WHERE APPLICABLE. 4. ENGINEER'S CERTIFICATION OF STORMWATER QUANTITY CONTROL: THE NET INCREASE IN BUILT -UPON AREA IS GREATER THAN 400 SQUARE FEET, THEREFORE, THIS DEVELOPMENT IS SUBJECT TO 30-12-7.2(B)(7)(b) OF THE GREENSBORO LAND DEVELOPMENT ORDINANCE. 5. ALL PUBLIC STORM SEWER MUST BE INSTALLED PER NCDOT SPECIFICATIONS. 6. PRIOR TO PUBLIC STORM SEWER INSTALLATION, CONTACT CHAD MANESS AT (336) 373-2336 TO SCHEDULE THE ASSIGNMENT OF AN INSPECTOR. 0 w z Lu a� N U� 0 z z 11 z 0 co VICINITY MAP 1 "=2000' SITE DATA PARCEL: 84035 PIN:7887697696 OWNER: GREENS APARTMENT LLC PROPERTY ADDRESS: 4717 4733 US HIGHWAY 29 N DB: 8643 PG: 2677 TOTAL SITE AREA: 23.82 ACRES RIGHT OF WAY DEDICATION: 2.47 ACRES EFFECTIVE SITE AREA: 21.35 ACRES ZONING: EXISTING ZONING: CD RM-18 LAND USE: MULTI-FAMILY/DUPLEX DEVELOPMENT STANDARDS: (SEE ZONING NOTES FOR SETBACK INFORMATION) MIN. BUILDING SEPARATION: 10' MAX. BUILDING HEIGHT ALLOWABLE: 80' MAX. BUILDING HEIGHT PROPOSED: 44' TOTAL NO. OF UNITS: 192 DENSITY: 192 UNITS / 23.82 AC = 8.06 UNITS/AC BUILDING COVERAGE: 90,214 SF (8.69%) DENSITY REQUIREMENT: 8,500 SF/DU FOR FIRST 3 DUs THEN 2,420 SF FOR EVERY ADDITIONAL LOT REQUIRED LOT SIZE: 8,500 SF + 457,380 = 465,880 SF (10.70 AC) AREA PROVIDED = 15.48 AC OPEN SPACE AREA REQUIRED: 435 SF X 192 UNITS = 83,520 SF (1.92 AC) AREA PROVIDED: 538,997 SF (12.37 AC) LN PARKING REQUIREMENTS AMENITY AREA: 1 PER 25 UNITS 0-1 BEDROOM: 1.25 PER UNIT 2 BEDROOM: 1.5 PER UNIT 3 BEDROOM: 2.0 PER UNIT PHASE 1 HAS 2-36 UNIT BUILDINGS AND 5-24 UNIT BUILDINGS AMENITY AREA: 192 UNITS @ 1 PER 25 UNITS = 8 SPACES I BEDROOM UNITS: 96 UNITS @ 1.25 SPACES PER UNIT= 120 SPACES 2 BEDROOM UNITS: 84 UNITS @ 1.5 SPACES PER UNIT= 126 SPACES 3 BEDROOM UNITS: 12 UNITS @ 2.0 SPACES PER UNIT = 24 SPACES TOTAL PARKING SPACES REQUIRED: 278 SPACES TOTAL PARKING SPACES PROVIDED: 279 SPACES GENERAL NOTES: 1. AREA DETERMINED UTILIZING COMPUTER SOFTWARE. 2. GRID TIE INFORMATION BASED ON MONUMENTATION AND DATUM AS SHOWN, ALL DISTANCES ARE GROUND DISTANCES (US FEET) UNLESS OTHERWISE SHOWN. 3. NO NGS MONUMENTS WERE RECOVERED WITHIN 2000' OF THIS PROPERTY. 4. NO SUBSURFACE INVESTIGATION PERFORMED BY FLEMING ENGINEERING, INC. 5. UTILITY LOCATION WORK SHOWN HEREON WAS DERIVED BY ABOVE GROUND INDICATORS ONLY, UNLESS OTHERWISE NOTED. 6. THIS PROPERTY IS SUBJECT TO ANY EASEMENTS, AGREEMENTS OR RIGHTS OF WAY RECORDED PRIOR TO THE DATE OF THIS MAP WHICH WERE NOT VISIBLE AT THE TIME OF INSPECTION. 7. THE SURVEYOR HAS NOT PERFORMED A TITLE INVESTIGATION ON THIS PROPERTY, THEREFORE, THIS MAP IS SUBJECT TO ANY AND ALL FACTS AN ACCURATE TITLE INVESTIGATION MAY DISCLOSE. 8. THIS MAP DOES NOT MEET G.S. 47-30 AND IS NOT FOR RECORDING OR CONVEYANCE. 9. THE CLASSIFICATION OF THIS SURVEY IS NORTH CAROLINA CLASS A. 10. HORIZONTAL DATUM: NAD83(2011). 11. ANY SIGNS TO BE PLACED ON SITE MUST BE SUBMITTED SEPARATELY FOR ZONING REVIEW. 12. PATIO/OVER HANG AREA IS GOING TO BE AN OPEN AREA THAT SHARES THE SAME ROOF AS THE OFFICE BUILDING. 13. ANY STRUCTURE TO BE REMOVED SHALL REQUIRE A SEPARATE DEMOLITION PERMIT FROM THE BUILDING INSPECTIONS DEPARTMENT. 14. MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED THROUGHOUT EXIT DISCHARGES IN ACCORDANCE WITH NCBC. 15. ALL EXISTING AND PROPOSED OVERHEAD POWER LINES ARE INDICATED ON THE SITE PLAN. IF NO OVERHEAD POWER LINES ARE INDICATED, THERE SHALL BE NONE WITHIN 10 FEET OF THE PROPERTY LIMITS. 16. HANDICAP SIGNAGE SHALL BE INSTALLED ON FACE OF BUILDING. CONTRACTOR TO COORDINATE LOCATION WITH OWNER AND ARCHITECTURAL PLANS. SITE PLAN NOTES: 1. ALL CONSTRUCTION SHALL CONFORM TO THE LATEST CITY OF GREENSBORO, GUILFORD COUNTY PLANNING & EROSION CONTROL, NCDEQ AND NCDOT STANDARDS AND SPECIFICATIONS. 2. ALL DIMENSIONS SHOWN ON SITE PLAN ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. 3. SOIL UNDER BUILDINGS AND PAVED AREAS SHALL BE COMPACTED TO STANDARD PROCTOR MAXIMUM DRY DENSITY AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER AND SHALL CONFORM TO CITY OF GREENSBORO REQUIREMENTS WITHIN PUBLIC RIGHT OF WAY. 4. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR TO CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND/OR RELOCATION OF ALL EXISTING UTILITIES IN COORDINATION WITH THE APPROPRIATE UTILITY, AGENCY, OR COMPANY. CONTRACTOR TO COORDINATE ACTIVITIES WITH UTILITY COMPANIES INVOLVED IN ANY RELATED RELOCATION (I.E. POWER POLES, TELEPHONE PEDESTALS, WATER METERS, ETC.). 6. EXISTING UTILITIES SHOWN ARE BASED ON FIELD SURVEYS AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY CONDITIONS PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND THE PLANS SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 7. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. UTILITY NOTES: 1. ALL CONSTRUCTION TO COG/NCDEQ STDS. 2. TERMINATE EXISTING, UNUSED WATER/SEWER TO THE MAIN TO COG STD. 3. METER, BACKFLOW PREVENTER AND ENCLOSURES TO COG STD. 4. ALL STANDARD NCDEQ/COG REQUIRED UTILITY SEPARATIONS MUST BE PROVIDED. 5. CONTACT JAY GUFFEY (336-373-7779) FOR A LIST OF APPROVED CONTRACTORS TO MAKE TAPS ON REHABILITATED MAINS. 6. COORDINATE METER REMOVAL WITH COG METER SHOP. #336-373-2071 7. THERE IS NOT AFIRE PUMP ASSOCIATED WITH THIS PROJECT. L ul O ro �, N j N LnZ E "= � p O v V O C � +' O V N 0 V) � O OvNZ w H- 00 N _ .-. 3 Q0 N V 00 W LL 0 �M J pp J w O H OZN a2wz w�W0 OaCo0 LL = zQwm U) �-w Z w 00 w o�� W (j V %O ` I J J \ V! W� ~ Z U) W W W J rn V Q WZ Q QO J 0WW< Q m Ow U O Z 5 Jw00 wO�ui O}Z)Q o w aUU� W O OLu o fY m 0 W x a Q o a` m zaaaaaaw DRAWN BY: LSM CHECKED BY: BCS DATE: 04/11 /2023 PROJECT NO.: 02031.001 REF. NO.: - SCALE: 1 50' CAROB N C� 7 R CtTN�N111, SHEET 6 O F 29 6 MIL. PLASTIC - SANDBAG PUMP EXCESS WATER TO APPROVED DEWATERING DRY WORK AREA SAND OR GRAVEL BAG COFFERDAM NOT TO SCALE TEMPORARY CREEK CROSSING PUMP AROUND DETAIL (NTS) EXISTING PLAN VIEW SECTION A -A I. DESCRIPTION THE WORK SHALL CONSIST OF INSTALLING A PUMP AROUND WHEN CONSTRUCTION ACTIVITIES TAKE PLACE WITHIN THE STREAM CHANNEL II. MATERIAL SPECIFICATIONS SANDBAGS: SANDBAGS SHALL CONSIST OF MATERIALS WHICH ARE RESISTANT TO ULTRAVIOLET RADIATION, TEARING AND PUNCTURE, AND WOVEN TIGHTLY ENOUGH TO PREVENT LEAKAGE OF FILL MATERIAL (i.e. SAND, FINE GRAVEL, ETC.) Ili. CONSTRUCTION REQUIREMENTS 1. ALL EROSION AND SEDIMENT CONTROL DEVICES SHALL BE INSTALLED AS THE FIRST ORDER OF WORK. 2. THE HEIGHT OF THE SANDBAGS SHALL BE AS INDICATED IN SECTION A -A. THE SANDBAGS SHALL BE PLACED ON A SMOOTH PREPARED SURFACE. 3. ALL EXCAVATED MATERIALS SHALL BE DISPOSED OF OUTSIDE THE 100 YEAR FLOOD PLAIN UNLESS APPROVED ON THE PLANS. 4. ALL DEWATERING OF THE CONSTRUCTION AREA SHALL BE PUMPED TO A DEWATERING PUMP DISCHARGE FILTER BAG OR SILT BASIN. 5. THE PUMP SHALL BE OF SUFFICIENT SIZE TO CONVEY NORMAL STREAM FLOW. 6. SEDIMENT CONTROL DEVICES ARE TO REMAIN IN PLACE UNTIL ALL DISTURBED AREAS ARE STABILIZED AND THE CITY ENGINEERING DEPT APPROVES THEIR REMOVAL. W3 FT. H2 CSIRCP N1 8" O.C.(TYP.) REFER TO CHART FOR BAR SIZE ELEVATION W2 (FT. 1 PLAN t_I 7 Y p VI 4JG� �1� R�TF� o ;uj� ¢ nm BEFORE YOU DIG! CONTACT ONE -CALL CENTER O � NOTES: D 6° * THIS PRECAST ENDWALL MAY BE USED FOR THE FOLLOWING STANDARDS: 838.01, 838.11, 838.21, 838,27, 838.33, sr = U LL _ 2L Z 838.39, 838.51, 838,57, 838.63 AND 838.69. © cn 2 * INSTALL PRECAST ENDWALLS WITH WINGS AND PAY w ¢ Q LL = FOR IN ACCORDANCE WITH SPECIFICATION SECTION 838. F_ U O 0 USE 4000 PSI CONCRETE. F- 2 ~ Z Lu U) O * PROVIDE ALL HEINFORCING STEEL WHICH MEETS ASTM A615 F` LL O Q FOR GRADE 60 AND WELDED WIRE FABRIC CONFORMING p I TO ASTM A165 WITH 2" MIN. CLEARANCE. Z •� H2 * PLACE LIFT HOLES OR PINS IN ACCORDANCE WITH CO � H OSHA STANDARD 1926.704. r Lu O I * PIPE TO BE GROUTED INTO HEADWALL AT JOB SITE BY T- j CONTRACTOR * ALL ELEMENTS PRECAST TO MEET AST# C913. - - WELDED WIRE FABRIC MAY BE SUBSTITUTED FOR REBAR AS LONG AS THE SAME AREA OF STEEL IS PROVIDED. CHAMFER ALL CORNERS I" OR HAVE A RADIUS OF 1". ijF-- B" O.C.(TYP.) REFER TO CHART i FOR BAR SIZE NOTE: THE MINIMUM BAR SIZE SHALL BE #5 BARS ui J � AT 8" CTS.THE CONTRACTOR WILL HAVE THE OPTION c O SIDE TO INCREASE THIS BAR SIZE AS NEEDED. LL 3 rn CD G , ENDWALL DIMENSIONS FT. MINIMUM MIN.IMAX. MIN./MAX. MIN./MAX. MIN.IMAX. MIN.IMAX. PIPE DIA. BAR SIZE H1(FT.) H2(FT.) 0 (FT.} W1 W2 1.0 #5 @ 8" 1.2512.00 2.00/3.75 1.25/1.75 3.0013.75 5.50/6.00 1.25 #5 @ 8" 1.2512,00 3.00/3.75 1.25/2.00 3.5013.75 6.50/6.75 1.50 #5 9 B" 1,25/2.00 3.0014.25 1.5012.50 3.5013.75 6.5016.75 2.0 #5 @ 8" 1.5012.50 4.0014,75 1.75/2.50 4.0014.25 7.5018.25 2.5 #5 @ B" 2.5013.50 4.00/6.00 2.00/3.00 4.5015.50 10.00/11.50 3.0 #5 @ B" 3.00/3.50 5.0016.00 2.75/3.50 5.2515,75 11.50/11.75 3.5 #5 @ 8" 3.25/4.50 6.0016.75 3.25/3.50 6.0016.75 12.00113.25 4.0 #5 @ 8" 3.50/4.50 6.50/7.00 3.25/3.50 6.5016.75 13,00/43.25 4.5 #5 @ 8" 4.0015,00 6.50/8.50 3.25/4.00 7.00/9.25 13.50/15.75 5.0 #5 @ 8" 4.50/5.00 7.0018.50 3,25/4.00 7.25/9.25 13.75/15.75 5.5 #5 @ 8" 4.50/5.00 7.50/8.50 3.25/4.00 7.2519.25 14.00115.75 6.0 #5 @ 8° 4.50/5.00 7,50/8.50 3.25/4.00 7.75/9.25 14.75116.75 UJ a cc W 1-CV O Cc EG n O U cc Q� � O U - cV Q 3: N w Q [_7 z 0 W co CL O u.. HEET 1 OF 1 838.80 PERMANENT BUFFER DISTURBANCE PZ 2B= 2,262 SF PERMANENT BUFFER DISTURBANCE 30'x 15'x2' CLASS 1 PZ 1 B- 3,984 SF RIP RAP PAD PERMANET STREAM �. I )3STURBANCE a S2= 141 SF (30 LF) `' n TPEFRI'MANENT MPORARY HEADWALL 001PASS PIPE NCDOT STD. 838.80INV: 745.00' BUFFER 'DISTURBANCEPZ 1A= 4122 SF -1+00 780 775 770 765 760 III 750 ►L°�7 740 PERMANENT BUFFER ` J DISTURBANCE PZ 2A= 1,976 SF j 0+00 E I If PROPOSED GRADE ijL � I I H W 001 STA. 0+00.00 RIM 753.50 IN 745-00 RIP RAP APRON / I , 0000 �0-00 0000 000 000*I CENTERLINE�OF STREAM T52:55SF 10LF()5 APPROXIMATE PUMP AROUND TEMPORARY i STREAM TOB TEMP. IMPACTS SANDBAGSHEADWALL 002/NCDOT STD. 838.80INV:750.P 4.16°/aZONE1 30'STREAM BUFFER ✓ZONE2 O'STREAM BUFFER`0000 i I \.. I - EXISTING GRADE OF !' \/ CROSSING CULVERT f %_FXISTING GRADE / OF STREAM CENTERLINE WETLANDS ` 0-00 TEMPORARY CREEK (TYP.) CROSSING PUMP 0000 (SEE DETAILS) �PERMANENT 0000 WETLAND DISTURBANCE - - W1= 357SF -PERMANENT STREAM IMPACT S1 = 680 SF (136 LF) 30 0 15 30 60 120 SCALE: 1" = 30' 1+00 HW 002 STA. 1+05.82 RIM 758.90 IN 750.40 2+00 4, p a 0 a VICINITY MAP 1 "=2000' SITE DATA PARCEL: 84035 PIN:7887697696 OWNER: GREENS APARTMENT LLC PROPERTY ADDRESS: 4717 4733 US HIGHWAY 29 N DB: 8643 PG: 2677 TOTAL SITE AREA: 23.82 ACRES RIGHT OF WAY DEDICATION: 2.47 ACRES EFFECTIVE SITE AREA: 21.35 ACRES ZONING: EXISTING ZONING: CD RM-18 LAND USE: MULTI-FAMILY/DUPLEX CROSSING EXHIBIT NOTES: 1. EXISTING GRADES ARE PROVIDED BY TOPOGRAPHIC SURVEY BY FFI AND NCDOT LIDAR, EXISTING SITE CONDITIONS ARE TO BE VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION. 2. UTILITY INSTALLATION AND IMPACTS SHALL FOLLOW ALL APPROVED PERMITS. 3. TEMPORARY STREAM CROSSING MATERIAL TO BE REMOVED FOLLOWING THE COMPLETION OF THE CULVERT CROSSING INSTALLATION. 4. CONTRACTOR TO VERIFY ELEVATIONS IN STREAM BED PRIOR TO INSTALLATION. ANY DISCREPANCIES BETWEEN PLAN AND FIELD CONDITIONS SHOULD BE NOTIFIED TO THE ENGINEER IMMEDIATELY. TEMPORARY IMPACT SUMMARY: TEMPORARY STREAM IMPACT TS 2: 10 LF155 SF PERMANENT IMPACT SUMMARY: ZONE 1: PERMANENT BUFFER IMPACT PZ 1A: 4,128 SF (0.095 AC) PZ 1 B: 3,984 SF (0.091 AC) ZONE 1 TOTAL: 8,112 SF (0.186 AC) ZONE 2: PERMANENT BUFFER IMPACT: PZ 2A: 1,976 SF (0.045 AC) PZ 28: 2,262 SF (0.052 AC) ZONE 2 TOTAL: 4,238 SF (0.097 AC) PERMANENT STREAM IMPACT: S1: 136 LF1680 SF (0.016 AC) S2: 30 LF1141 SF (0.013 AC) TOTAL: 821 SF (0.019 AC) PERMANENT WETLAND IMPACT: W1: 357 SF (0.008 AC) STORMWATER MANAGEMENT INFORMATION 1. THIS PROPERTY IS LOCATED WITHIN FLOOD ZONE X (ZONE X AREAS ARE DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN) AREA AS INDICATED ON THE FLOOD INSURANCE RATE MAP (FIRM) MAP NUMBER 3710788700J, EFFECTIVE DATE JUNE 18TH, 2007. 2. BUILT UPON AREA (BUA) TOTAL AREA: 930,079 SF 21.35 ACRES EXISTING BUA: 103,237 SF 2.31 ACRES (11.10%) EXISTING BUA TO BE REMOVED: 87,556 SF 2.01 ACRES (9.40%) PROPOSED BUILT UPON AREA: 280,091 SF 6.43 ACRES (30.12%) TOTAL BUA: 295,772 SF 6.79 ACRES (31.80%) 3. ALL NECESSARY APPROVALS HAVE BEEN (WILL BE) OBTAINED FROM NCDEQ AND U.S. ARMY CORPS OF ENGINEERS FOR ANY WETLAND DISTURBANCE AND STREAM CROSSINGIDISTURBANCE WHERE APPLICABLE. 4. ENGINEER'S CERTIFICATION OF STORMWATER QUANTITY CONTROL: THE NET INCREASE IN BUILT -UPON AREA IS GREATER THAN 400 SQUARE FEET, THEREFORE, THIS DEVELOPMENT IS SUBJECT TO 30-12-7.2(13)(7)(b) OF THE GREENSBORO LAND DEVELOPMENT ORDINANCE. 5. ALL PUBLIC STORM SEWER MUST BE INSTALLED PER NCDOT SPECIFICATIONS. 6. PRIOR TO PUBLIC STORM SEWER INSTALLATION, CONTACT CHAD MANESS AT (336) 373-2336 TO SCHEDULE THE ASSIGNMENT OF AN INSPECTOR. 7. STORM AS-BUILTS REQUIRED FOR ALL NEW PIPES 12" AND LARGER, AFTER TRC APPROVAL, SUBMIT (1) SET OF PLANS TO THE ENGINEERING DEPARTMENT FOR RECORD PURPOSES. PLEASE CALL (336) 373-2052 WITH QUESTIONS. 3 0 1.5 3 6 12 VERTICAL SCALE: 1" = 3' 30 0 15 30 60 120 HORIZONTAL SCALE: 1" = 30' 2� �s N� a CARLA LN /0 Ln O m >' CV QJ r > CV V V) Z CraE m �° o Ln v - I• CD L L 73 � 7 Q V1 f iJ ,L Liz LL 41 Ln _ 00 2 V 00 0 cc Iwo O V N z E- w W- F- wz O Oaw0 z¢ww _U) --U) Ofz¢z wwF-w zw0w Wb(�?o� (D H J = J x W V J z Z W rU) VJ UJ 0N ry L.L i i V z O Oita¢ 1-000 Q CO LL 0ZD� _j Lu z wO�ui p> �¢ x a. 0 U V) Action ID Number: SAW-2023-00402 County: Guilford Permittee: Blu Ladder Construction, LLC, Attn: Jay Gaffney Project Name: Greens Village / Esterwood Road / Greensboro Date Verification Issued: 06/30/2023 Project Manager: David E. Bailey Upon completion of the activity authorized by this permit and any mitigation required by the permit, sign this certification and return it to the following address: US ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Attn: David E. Bailey Raleigh Regulatory Office U.S Army Corps of Engineers 3331 Heritage Trade Drive, Suite 105 Wake Forest, North Carolina 27587 or David.E.Bailey2@usace.army.mil Please note that your permitted activity is subject to a compliance inspection by a U. S. Army Corps of Engineers representative. Failure to comply with any terms or conditions of this authorization may result in the Corps suspending, modifying or revoking the authorization and/or issuing a Class I administrative penalty, or initiating other appropriate legal action. I hereby certify that the work authorized by the above referenced permit has been completed in accordance with the terms and condition of the said permit, and required mitigation was completed in accordance with the permit conditions. Signature of Permittee Date A. Determination of Jurisdiction: 1. ® There are waters, including wetlands on the above described project area that may be subject to Section 404 of the Clean Water Act (CWA) (33 USC § 1344) and/or Section 10 of the Rivers and Harbors Act (RHA) (33 USC § 403). This preliminary determination is not an appealable action under the Regulatory Program Administrative Appeal Process (Reference 33 CFR Part 331). However, you may request an approved JD, which is an appealable action, by contacting the Corps district for further instruction. Please note, if work is authorized by either a general or nationwide permit, and you wish to request an appeal of an approved JD, the appeal must be received by the Corps and the appeal process concluded prior to the commencement of any work in waters of the United States and prior to any work that could alter the hydrology of waters of the United States. 2. ❑ There are Navigable Waters of the United States within the above described project area subject to the permit requirements of Section 10 of the Rivers and Harbors Act (RHA) (33 USC § 403) and Section 404 of the Clean Water Act (CWA) (33 USC § 1344). This determination may be relied upon for a period not to exceed five years from the date of this notification, provided there is no change in law or our published regulations or new information that warrants revision of this determination. 3. ❑ There are waters, including wetlands within the above described project area that are subject to the permit requirements of Section 404 of the Clean Water Act (CWA) (33 USC § 1344). This determination may be relied upon for a period not to exceed five years from the date of this notification, provided there is no change in law or our published regulations or new information that warrants revision of this determination. 4. A jurisdiction determination was not completed with this request. Therefore, this is not an appealable action. However, you may request an approved JD, which is an appealable action, by contacting the Corps for further instruction. 5. ❑ The jurisdictional areas within the above described project area have been identified under a previous action. Please reference jurisdictional determination issued _. Action ID: _. B. Basis For Determination: See the preliminary jurisdictional determination form dated 06/30/2023. C. Remarks: D. Attention USDA Program Participants This delineation/determination has been conducted to identify the limits of Corps' Clean Water Act jurisdiction for the particular site identified in this request. The delineation/determination may not be valid for the wetland conservation provisions of the Food Security Act of 1985. If you or your tenant are USDA Program participants, or anticipate participation in USDA programs, you should request a certified wetland determination from the local office of the Natural Resources Conservation Service, prior to starting work. E. Appeals Information for Approved Jurisdiction Determinations (as indicated in A2 and A3 above). If you object to this determination, you may request an administrative appeal under Corps regulations at 33 CFR Part 331. Enclosed you will find a Notification of Appeal Process (NAP) fact sheet and Request for Appeal (RFA) form. If you request to appeal this determination you must submit a completed RFA form to the following address: US Army Corps of Engineers South Atlantic Division Attn: Philip Shannin, Appeal Review Officer 60 Forsyth Street SW, Room M9 Atlanta, Georgia 30303-8801 Phone: (404) 562-5136 AND Philip. a. shannin(a)usace. army. mil In order for an RFA to be accepted by the Corps, the Corps must determine that it is complete, that it meets the criteria for appeal under 33 CFR part 331.5, and that it has been received by the Division Office within 60 days of the date of the NAP. Should you decide to submit an RFA form, it must be received at the above address by Not applicable. It is not necessary to submit an RFA form to the Division Office if you do not o ject to the determination in this correspondence. Corps Regulatory Official: David E. Bailey Date of JD: 06/30/2023 Expiration Date of JD: Not applicable NOTIFICATION OF ADMINISTRATIVE APPEAL OPTIONS AND PROCESS AND REQUEST FOR APPEAL Applicant: Blu Ladder Construction, LLC, Attn: File Number: SAW-2023-00402 Date: 06/30/2023 Jay Caffne Attached is: See Section below ❑ INITIAL PROFFERED PERMIT (Standard Permit or Letter of permission) A ❑ PROFFERED PERMIT (Standard Permit or Letter of permission) B ❑ PERMIT DENIAL WITHOUT PREJUDICE C ❑ PERMIT DENIAL WITH PREJUDICE D ❑ APPROVED JURISDICTIONAL DETERMINATION E ❑x PRELIMINARY JURISDICTIONAL DETERMINATION F SECTION I The following identifies your rights and options regarding an administrative appeal of the above decision. Additional information may be found at https://www.usace.armv.mil/Missions/Civil-Works/Regulatory- Program-and-Permits/appeals/ or Corps regulations at 33 CFR Part 331. A: INITIAL PROFFERED PERMIT: You may accept or object to the permit • ACCEPT: If you received a Standard Permit, you may sign the permit document and return it to the district engineer for final authorization. If you received a Letter of Permission (LOP), you may accept the LOP and your work is authorized. Your signature on the Standard Permit or acceptance of the LOP means that you accept the permit in its entirety, and waive all rights to appeal the permit, including its terms and conditions, and approved jurisdictional determinations associated with the permit. • OBJECT: If you object to the permit (Standard or LOP) because of certain terms and conditions therein, you may request that the permit be modified accordingly. You must complete Section II of this form and return the form to the district engineer. Upon receipt of your letter, the district engineer will evaluate your objections and may: (a) modify the permit to address all of your concerns, (b) modify the permit to address some of your objections, or (c) not modify the permit having determined that the permit should be issued as previously written. After evaluating your objections, the district engineer will send you a proffered permit for your reconsideration, as indicated in Section B below. B: PROFFERED PERMIT: You may accept or appeal the permit • ACCEPT: If you received a Standard Permit, you may sign the permit document and return it to the district engineer for final authorization. If you received a Letter of Permission (LOP), you may accept the LOP and your work is authorized. Your signature on the Standard Permit or acceptance of the LOP means that you accept the permit in its entirety, and waive all rights to appeal the permit, including its terms and conditions, and approved jurisdictional determinations associated with the permit. • APPEAL: If you choose to decline the proffered permit (Standard or LOP) because of certain terms and conditions therein, you may appeal the declined permit under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the division engineer. This form must be received by the division engineer within 60 days of the date of this notice. C. PERMIT DENIAL WITHOUT PREJUDICE: Not appealable You received a permit denial without prejudice because a required Federal, state, and/or local authorization and/or certification has been denied for activities which also require a Department of the Army permit before final action has been taken on the Army permit application. The permit denial without prejudice is not appealable. There is no prejudice to the right of the applicant to reinstate processing of the Army permit application if subsequent approval is received from the appropriate Federal, state, and/or local agency on a previously denied authorization and/or certification. D: PERMIT DENIAL WITH PREJUDICE: You may appeal the permit denial You may appeal the denial of a permit under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the division engineer. This form must be received by the division engineer within 60 days of the date of this notice. E: APPROVED JURISDICTIONAL DETERMINATION: You may accept or appeal the approved JD or provide new information for reconsideration • ACCEPT: You do not need to notify the Corps to accept an approved JD. Failure to notify the Corps within 60 days of the date of this notice means that you accept the approved JD in its entirety and waive all rights to appeal the approved JD. • APPEAL: If you disagree with the approved JD, you may appeal the approved JD under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the division engineer. This form must be received by the division engineer within 60 days of the date of this notice. • RECONSIDERATION: You may request that the district engineer reconsider the approved JD by submitting new information or data to the district engineer within 60 days of the date of this notice. The district will determine whether the information submitted qualifies as new information or data that justifies reconsideration of the approved JD. A reconsideration request does not initiate the appeal process. You may submit a request for appeal to the division engineer to preserve your appeal rights while the district is determining whether the submitted information qualifies for a reconsideration. F: PRELIMINARY JURISDICTIONAL DETERMINATION: Not appealable You do not need to respond to the Corps regarding the preliminary JD. The Preliminary JD is not appealable. If you wish, you may request an approved JD (which may be appealed), by contacting the Corps district for further instruction. Also, you may provide new information for further consideration by the Corps to reevaluate the JD. POINT OF CONTACT FOR QUESTIONS OR INFORMATION: If you have questions regarding this decision you If you have questions regarding the appeal process, may contact: or to submit your request for appeal, you may District Engineer, Wilmington Regulatory Division contact: Attn: David E. Bailey Philip Shannin Raleigh Regulatory Office Regulatory Appeals Review Officer U.S Army Corps of Engineers South Atlantic Division 3331 Heritage Trade Drive, Suite 105 60 Forsyth St SW, Floor M9 Wake Forest, North Carolina 27587 Atlanta, Georgia 30303-8803 Philip.A.Shannin2(a�usace.army.mil 404-562-5136 SECTION II — REQUEST FOR APPEAL or OBJECTIONS TO AN INITIAL PROFFERED PERMIT REASONS FOR APPEAL OR OBJECTIONS: (Describe your reasons for appealing the decision or your objections to an initial proffered permit in clear concise statements. Use additional pages as necessary. You may attach additional information to this form to clarify where your reasons or objections are addressed in the administrative record.) ADDITIONAL INFORMATION: The appeal is limited to a review of the administrative record, the Corps memorandum for the record of the appeal conference or meeting, and any supplemental information that the review officer has determined is needed to clarify the administrative record. Neither the appellant nor the Corps may add new information or analyses to the record. However, you may provide additional information to clarify the location of information that is already in the administrative record. RIGHT OF ENTRY: Your signature below grants the right of entry to Corps of Engineers personnel, and any government consultants, to conduct investigations of the project site during the course of the appeal process. You will be provided a 15-day notice of any site investigation and will have the opportunity to participate in all site investigations. Date: Signature of appellant or agent. Email address of appellant and/or agent: Telephone number: