Loading...
HomeMy WebLinkAbout310023_Add-Info Request_20230630ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Stan Bowles Bowles & Son Farm #1 607 Curtis Rd Warsaw, NC 28398 Dear Stan Bowles: NORTH CAROLINA Environmental Quality June 30, 2023 Subject: Additional Information Request Application No. ADS310023 Bowles & Son Farm #1 Duplin County The Animal Feeding Operations Program of the Division of Water Resources (Division) has completed a preliminary review of the subject application received on March 22, 2023, for permit coverage under Swine Farm Digester Waste Management System General Permit AWG400000 to convert an existing lagoon into digester to capture biogas as a part of the proposed farm digester system at the Bowles & Son Farm #1. Additional information is required before we may continue our review. Please address and submit the following item(s) within 30 (thirty) days of receipt of this letter. ❑ Mailing Address —The Mailing Address shown on the application differs from the Mailing Address of Record for owner Stan Bowles. Please confirm the correct Mailing Address. ❑ Stormwater Outlet — Please provide a typical detail, including dimensions, for outlet for stormwater removed from digester covers. Please also indicate stormwater outlet location. ❑ Freeboard — NC NRCS Standard 366 — Anaerobic Digester requires a minimum of 2 feet of freeboard in the covered digester. Please verify that the digester will meet minimum freeboard requirements. ❑ Biogas Use as a Renewable Energy Resource — Session Law 2023-63 (2023 Farm Act) requires that the gases collected by a farm digester system begin to be used as a renewable energy resource as quickly as feasible, but no later than within six months of the collection of gases. Until the gases are being used as a renewable energy resource the gas shall be flared rather than vented. Please provide information for the intended onsite and/or offsite use of biogas. Please include expected timeline regarding when collection of gases begins, completion of digester system, and utilization of gas as a renewable energy resource. ❑ Gas Generation Estimate — Please submit an estimate for the daily volume of biogas to be generated by the proposed Digester. ❑ Emergency — Please provide location/identification for the emergency flare(s). ❑ Influent/Effluent Sampling — Please indicate location for sampling of influent to and effluent from each digester. ❑ Waste Level Gauge — Please indicate location/method for measuring waste levels in the digester, as it does not gravity feed to the secondary containment. North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 1 1636 Mail Service Center I Raleigh, North Carolina 27699-1636 NORTH CARCLINA 919.707.9129 Stan Bowles ADS310023 Additional Information Letter June 30, 2023 Page 2 of 2 ❑ Tail Gas from Gas Upgrading SystemGUS) — Plans indicate that a GUS will be installed onsite to process the biogas. How will tailgas or remnant biogas be managed? It appears to be introduced back into the existing lagoon/secondary treatment lagoon. Please provide results of study to support this remnant biogas management. Will this affect the effluent in the lagoon? Potential odor issues and if so, what odor control measures will be implemented?. ❑ Odor Control Checklist — Recommend updating to the new Odor Control Checklist. See Attached. ❑ O&M Plan — The Contact Information for Christine Lawson should be updated as follows: Christine Lawson, Animal Feeding Operations Program, Div. of Water Resources, 1636 Mail Service Center, Raleigh, NC 27699-1636, 919-707-3664. Christine.Lawsonkdeq.nc.gov ❑ Air Quality Permitting — Please provide general information regarding any Air Quality permits, and/or applicability determinations regarding this project. Please provide information about if applications have been filed, permits (if issued), and/or results of an applicability determination. Please be aware that you are responsible for meeting all requirements set forth in North Carolina rules and regulations. Any oversights that occurred in the review of the subject application package are still the responsibility of the applicant. In addition, any omissions made in responding to the above items shall result in future requests for additional information. Please reference the subject application number when providing the requested information. All revised and/or additional documentation shall be signed, sealed and dated, submitted to my attention at the address below. Failure to provide this additional information on or before the above requested date may result in your application being returned as incomplete. If you have any questions regarding this letter, please feel free to contact me at (919) 707-3664 or Christine.Lawson@deq.nc.gov. Sincerely, E DocuSigned by:I� ViS{iv t, fj. (Aws6w 715598483EA94B7... Christine B. Lawson Engineer Animal Feeding Operations cc: Wilmington Regional Office, Water Quality Regional Operations Section — via email Cavanaugh & Associates — Jeff Cappadona Laserfiche — File No. 310023 REQ5 North Carolina Department ofEnvironmental Quality I Division ofWater Resources 512 North Salisbury Street 1 1636 Mail Service Center I Raleigh, North Carolina 27699-1636 NORTH CAROLINA 919.707.9129 onparhnem of EmironmanW 9uallly