Loading...
HomeMy WebLinkAboutNCG050139_Inspection Report - IPEX USA LLC_20230627C��rf�lrie-J4fetkJanburg STORM CATER SuviceS Facility Inspection sfo rmW a fe r. C ha rMe c k. arg Facility Name: IPEX USA LLC Inspection # : 75887 Contact: Kyerra Heath, HSE Coordinator Permit #: NCG050139 Inspector: Ron Eubanks Receiving Stream: LOWER LITTLE SUGAR Inspection Date: 06/20/2023 Entry Time: 10:00 am Exit Time: 12:30 pm SIC #: Er SUMMARY llllllnmv� Facility Description: The IPEX USA LLC facility is located on approximately 35.8 acres of property at 10100 Rodney Street in Pineville. Operations at the facility include the manufacturing and shipping of pipes, valves, fittings, and auxiliary components for municipal, industrial, and electrical applications. File Review/History: Charlotte -Mecklenburg Storm Water Services (CMSWS) has conducted previous inspections at IPEX USA LLC on 05/18/2017, 04/13/2018, 07/18/2018, and 09/10/2018. A Notice of Violation (NOV) was issued on April 16, 2018 for the illicit discharge of residual resin material to catch basins throughout the site that had accumulated at the facility's outfall. A NOV was also issued on July 19, 2018 for the illicit discharge of treated process wastewater from oil and water separators at the front and rear of the facility, and for repeated discharges of oil -contaminated mop water and/or other oily discharges to the ground near the railroad spur. Inspection Summary: At the time of inspection, IPEX USA LLC was observed to be in compliance with the Mecklenburg County Surface Water Pollution Control Ordinance. Please refer to the report for comments and recommendations from the inspection. Site Inspection Deficiency Comments Stormwater system (catch basins, Recommendation Stormwater runoff drains by sheet flow into a series of catch inlets, outfalls, etc.) basins which discharge from the property via one outfall. There was standing water observed in the trench drain near the manufacturing building. CMSWS recommends that the trench drains be cleaned to allow the standing water to drain. Inlet filters were observed in the catch basins in the manufacturing and outdoor storage areas on the property. CMSWS recommends that the inlet filters be routinely inspected and cleaned as needed. Erosion issues No There were no stormwater erosion issues observed on the property. Structural stormwater control N/A There were no SCMs observed on the property. measures (SCMs) Illicit discharges/connections No There were no illicit discharges or connections observed on the property during the inspection. Aboveground storage tank(s) (ASTs) No There is one 500-gallon off -road diesel fuel AST located on and any associated venting and/or the property. The AST has double -walled secondary dispenser(s) — list tank size(s) and containment. No stormwater pollution issues were observed. contents Underground storage tank(s) (USTs) N/A According to facility personnel, there are no USTs located on and any associated fill port area(s) the property. and dispenser(s) — list tank size(s) and contents • ((� To report pollution or drainage problems call: 311 CHARLOTTE_ http://stormwater.charmeck.org 6/27/2023 4:56:07PM 0 Page 1 of 4 Site Inspection Deficiency Comments Outdoor material storage area(s) Recommendation Finished product and off -specification product to be processed are stored outdoors. There was resin PVC material observed on the ground in the outdoor material storage area during the inspection. The resin PVC material should be cleaned up and properly stored to prevent stormwater exposure and protect water quality. Outdoor processing area(s) No Off -specification product is processed outdoors into a powder for reuse on site or to be shipped offsite to other IPEX facilities. No stormwater pollution issues were observed. Loading/unloading area(s) No No stormwater pollution issues were observed in the loading and unloading areas. Vehicle/equipment area(s) - fueling, No Facility forklifts are fueled, maintained, and stored onsite. maintenance, washing, storage, etc. According to facility personnel, no washing activities are conducted on the property. No stormwater pollution issues were observed. Oil/water separator and/or No There are two oil/water separators located on the property. pretreatment According to facility personnel, the oil/water separators are connected to the sanitary sewer system. The oil/water separators should be routinely inspected and cleaned to ensure they function properly. Waste storage/disposal area(s) - Recommendation The municipal waste compactor has been temporarily open tops, waste containers, scrap removed from the property for maintenance. There are several metal bins, etc. roll -off containers for waste and recyclable materials located on the property. Some of the roll -off containters were observed to be uncovered. CMSWS recommends all outdoor waste and recyclables containers be covered to prevent stormwater exposure. Food service area(s) N/A Indoor material storage area(s) No Raw materials, parts, and maintenance equipment are stored inside the manufacturing building. New and used motor oil and hydraulic oil for the forklifts are located in a storage building on the property. No stormwater pollution issues were observed in the indoor material storage areas. Indoor processing area(s) No No stormwater pollution issues were observed in the indoor processing areas. Floor drains N/A There were no floor drains observed during the inspection. Spill response equipment No Spill kits are placed at several locations on the property. The spill kits should be routinely inspected and restocked as needed. SWPPP Section Observed Comments Does the facility have a Stormwater Pollution Prevention Plan (SWPPP)? Yes A Stormwater Pollution Prevention Plan (SWPPP) has been prepared and implemented for IPEX USA LLC. Reviewed and updated annually Yes The SWPPP was reviewed and updated in June 2022. Responsible party Yes General location (USGS) map No A general location (USGS) map should be prepared and included in the SWPPP. Detailed site map Yes Narrative description of industrial processes Yes Feasibility study N/A Evaluation of stormwater outfalls (non -stormwater discharge evaluation) No The facility should conduct annual non-stormwater discharge evaluations of the outfall and document in the SWPPP. • (& To report pollution or drainage problems call: 311 CHARIATTE. http://stormwater.charmeck.org 6/27/2023 4:56:07PM Page 2 of 4 SWPPP Section Observed Comments Stormwater best management Yes practice (BMP) summary Secondary containment plan (all Yes necessary secondary containment provided and documented) Records on every release from a N/A The AST has double -walled secondary containment. secondary containment system (for the last 5 years) Spill prevention and response Yes procedures (SPRP) List of significant spills or leaks (for Yes According to facility personnel, there have been no significant the last 3 years) spills on the property in the last three years. A "notation of no spills" was documented in the SWPPP. Solvent management plan (SMP) Recommendation A solvent management plan is a requirement of the new NCG 050000 permit. Preventative maintenance and good Yes housekeeping program (PMGHP) Facility inspections conducted as Yes According to personnel, inspections are conducted on a required monthly basis utilizing a facility checklist and documented in the SWPPP. The recent facility inspection was conducted on May 15, 2023. Employee training (provided and Yes The recent employee training was conducted in June 2022 documented) and documented in the SWPPP. Qualitative/Analytical Monitoring Observed Comments Qualitative monitoring conducted as No The recent qualitative monitoring was conducted on June 6, required 2022. Quarterly qualitative monitoring is a permit requirement. Analytical monitoring conducted as Recommendation Analytical monitoring is a requirement of the new NCGO50000 required permit to begin the first quarter of 2024. Analytical monitoring for onsite N/A According to facility personnel, equipment maintenance vehicle and equipment maintenance activities do not exceed 660 gallons of new motor oil and/or as required hydraulic oil per calendar year. Permit and Outfalls Observed Comments Copy of permit and certificate of Yes IPEX USA has has Certificate of Coverage No. NCG050139. A coverage onsite copy of the permit and certificate of coverage is included in the SWPPP. All outfalls observed Yes There were no stormwater pollution issues observed at the outfall. Number of Outfalls Observed 1 Representative outfall status N/A documented by DEMLR Annual no -exposure self re-certificatio N/A n documented Phase II Permit Requirements Observed Comments Is the permittee properly disposing of N/A wastes removed from the streets, parking lots and the MS4 and documenting the quantity (lbs., cubic yards)? Were any public transportation (road N/A way) projects constructed within the last year? • ((� To report pollution or drainage problems call: 311 � CttARL(YFTE_ http://stormwater.charmeck.org 6/27/2023 4:56:07PM Page 3 of 4 Phase II Permit Requirements Observed Comments Is the permittee implementing BMPs N/A (and maintaining records) to reduce polluted stormwater runoff from the municipally owned streets, roads, and public parking lots? Is the permittee implementing BMPs N/A (and maintaining records) to reduce polluted stormwater runoff from the municipally owned or maintained stormwater catch basins and conveyance systems? Did the Co-Permittee provide N/A pesticide license numbers (indicate license #) for all employees and contractors performing application activities and was license verified on the NC Dept. of Agriculture website (i ndicate Expiration date)? Does the permittee document areas N/A treated with pesticides/herbicides for comparison to annual thresholds? Did permittee comply with pesticide N/A limitations specific to the Goose Creek Watershed? Is the permittee implementing BMPs N/A According to facility personnel, no vehicle or equipment to reduce polluted storm water runoff washing activities are conducted on the property. from vehicle and equipment cleaning areas? • ((� To report pollution or drainage problems call: 311 CHARLOTTE_ http://stormwater.charmeck.org 6/27/2023 4:56:07PM Page 4 of 4