Loading...
HomeMy WebLinkAboutNC0021601_Idustrial Waste Survey-Pretreatment Program_20230622Town a Tryon Wastewater Treatment Plant 301 N. Trade Street Tryon, N.C. 28782 June 13, 2023 Keys McGee, Pretreatment Coordinator PERCS-Pretreatment NC Division of Water Resources 1617 Mail Service Center Raleigh, N.C. 27699-1617 Subject: Industrial Waste Survey Tryon Wastewater Treatment Plant Pretreatment Program Polk County Dear Mr. McGee: RECEIVED JUN 2 2 2023 NCDEQ/DWR/NPDES Please find enclosed two different sources of information used to determine which users should be sent IWS forms. I used the North Carolina Manufactures Register and their SIC codes and I also contacted the billing clerk at Town Hall for water billing records as my second source. I've also included the IWS checklist, IWS short and long forms, Chemical Addendum and the IWS submission form. If you have questions, please call me at (828) 859-5626 or my email debmbradley@hotmail.com. Sincerely, Deborah Bradley,ORC Tryon WWTP =ACTURERS REGISTERO--2015 © Copyright 2015 Manufacturers' News, Inc. D537 ;6 n as, Inc., linston- ;II profile 26 lary 7 ntl. iG, licucc ssiter & 71) file. MEGAWOOD, INC. 960 N. Main St., P.O. Box 464 (27371-0464) Phon"910) 572-3796 Fax—(910) 576-1088 Pres., pers. Mgr. —Bill Hamilton Hum. Res. Mgr. —Sue Hamilton Off. Mgr. —Megan Lemonds SIC-2426; Southern yellow pine remanufacturing Employs-20; Estab.-1985 Sales—$1 Mil-$5Mil 7,200 sq ft site, Distrib.—Regional Privately owned corporation MONTGOMERY HERALD 139 Bruton St., P.O. Box 466 (27371) Phone—(910) 576-6051 Fax—(910) 576-1050 www.montgomeryheraid.com Email —advertise@ montgomeryherald.com Pres., R & D Mgr. —Charles Womack Off. Mgr. —Tammy Haywood Reporter —Tammy Dunn SIG-2711; Newspaper publishing Employs-6; Estab.-1909 21,204 sq ft site, Distrib.—National Privately owned corporation PARSON'S MACHINE WORKS 890 Albemarle Rd. (27371) Phone--(910) 576-8001 Owner—Coite Parsons V-P.—Greg Parsons SIC-3499; 3599; Metal fabrication & machining job shop Employs-2; Estab.-1962 Sales —under $500,000 Distrib.—Local Privately owned corporation ROBINWOOD ENTERPRISES 180 E. Glen Rd., P.O. Box 707 (27371) Phone--(910) 571-0145 Fax—(910) 571-0146 Owner & GM —Terry Britts Off. Mgr. —Renee Britts SIC-2252; Socks Employs-15; Estab.-1993 Sales—$1 Mil-$2.5Mi1 Distrib.—Regional Sole ownership S F K FURNITURE CORP. 191 Byrd St. (27371) Phone-4910) 571-0461 Fax—(910) 571-0717 www.sfkfurniture.com Email—sfkfurn @earthlink.net Pres.—Thomas Kornegay, Jr. V-P.—Stephanie Kornegay SIC-2511; Outdoor wooden lawn furniture, including porch swings, benches, dining sets, teak chairs & tables Employs-2; Estab.-1999 Sales —under $500,000 Distrib.—Intl. Privately owned corporation TROY LUMBER CO. 110 Leslie St., P.O. Box 748 (27371) Phone— (910) 576-6111 Fax—(910) 576-2453 Pres.—Fredrick H. Taylor Hum. Res. Mgr. —Terry Brown SIC-2421; Southern yellow pine lumber processing Employs-100; Estab.-1948 100,000 sq It site, Distrib.— National Privately owned corporation TROY READY MIX, INC. 1739 Highway 24 at Highway 27 W.(27371) Phone--(910) 572-1011 National—(800) 525-9053 Fax—(910) 572-3711 Pres., Put., Sales & Mktg. Mgr. — James Macon V-P.—Robert Foushee Secy., Hum. Res. & IT Mgr. — Jeffrey T. Macon SIG-3272; 3273; NAICS- 327320; Precast concrete products & ready -mixed concrete Employs-9; Estab.-1969 7,000 sq ft site, Distrib.—Local Privately owned corporation UWHARRIE LUMBER CO. 335 Page St., P.O. Box 533 (27371) Phone—(910) 572-3731 Fax—(910) 572-9663 Pres.—Franklin R. Allen CFO —Michelle Greene SIC-2421; Hardwood lumber processing Employs-70 Sales-410Mil-$25Mil (est) Distrib.—Local Privately owned corporation WHARRIE BLINDS & CUSTOM CURTAINS 3076 Highway 109 (27371) Phone—(910) 572-2118 www.uwharriecustomcurtains.com Email—uwharriecurtains @ yahoo.com Ptnr. & Floor Mgr. —Daniel Threadgill Ptnr.—Shirley Threadgill SIC-2391; 2591; 2511; NAICS- 314121; Custom curtains, blinds & wooden residential furniture Employs-2; Estab.-1989 Distrib.—Local WOOD RIGHT LUMBER CO. 225 Basswood Rd. (27371) Mail addr: P.O. Box 618, Badin (28009-0618) Phone— (910) 576-4642 www.inskeep.orgg Email—wrlcous @ yahoo.com Pres.—Georgia Inskeep Opers. Mgr. —Angela Inskeep Burleson SIC-2452; 2879; 5031; NAICS- 321992, Prefabricated post, beam & geodesics, including decking & flooring & insect mold & mildew preventative/ preservative treatment & wholesaler of rail & bridge timbers & alternative energy specification, installation & energy auditing services Employs--4; Estab.-1985 Sales —under $5Mil Distrib.—Regional Limited Liability Company DBA: Dex N DOX Tryon (Polk—S.W.) tANDWIN SCIENTIFIC, INC. 69 Pacolet St., Ste. 240 (28782) Phone—(828) 859-5880 National—(888) 560-4969 Fax—(828) 859-9353 www.andwinsci.com Email—sales@andwinsci.com Sales Mgr. —Jason Seay SIC-5049; Distributor of laboratory microscopes Employs-3; Estab.-1976 Distrib.—National Privately owned corporation Parent co.—Andwin Scientific, Inc., Woodland Hills, CA Phone—(818) 999-2828 See Parent Co. Section for full profile. ARLEDGE PRINTERS, INC. 225 N. Trade St. (28782) Phone--(828) 859-9530 Fax —(8 ) 859-5 45 Email—ar dg 9 tern@ �✓ windstrea .n Pres.—Hub edge ��, GM—Richa ardin SIC-275 2 ;NAICS- 323100• om rcial & instant printin .V Employs-3; Est .-1940 Sales —under $500,000 2,400 sq ft site, Distrib.—Regional Privately owned corporation l /��/l���iN/�GZst✓�' cl!P 250 Scriven Rd., P.O. Box 1579 I (28782) Phone—(828) 859-5891 Fax—(828) 859-9024 Email—cypdyedyarn @ alltel.net V-P.—Ginger Stone SIC-2269; NAICS-313300; Yarn dyeing & processing Employs-80; Estab.-1957 Distrib.—National Privately owned corporation COOPER STUDIO, J. T. P.O. Box 11 (28782) Pho6e—(828) 894-8762 www.jtcool)erstudio.com Email—info@itcooperstudiWm Pres.—Joe Cooper SIC-3648; NAICS-335129; '19 ':i� Custom copper & textured C, bronze lighting fixtures `V Employs-2; Estab.-1994 �r - Sales —under $500,000 Distrib.—National Sole ownership GLEASON POTTERY 35 Erskine Rd. (28782) Phone—(828) 859-9387 www.southernhighlandcraftguild.c om Email—gleason.ann @gmail.com Owner —Ann E. Gleason SIC-3269; NAICS-327112, Functional stoneware & ceramic sculptures Employs-1; Estab.-1985 Sales —under $100,000 Distrib.—National Sole ownership HENSONS', INC. 105 Ridge Rd., P.O. Box 1060 (28782 Phone—(828) 859-5836 Fax—(828) 859-9091 /q/ www.hensonsinc.net � Email-hensoi s@hensonsinc.net� - Pres.,Ellis Fincher III & IT)Dpers. Mgr. —Randy IC-287 ; NAt( S-325314, Mulch / `� EmployA-60; Esta 1933 Sales—$10Mi1-$25MI Distrib.—Regional Privately owned corporation PLAIN PATH PUBLISHERS Henry Thompson Rd. (2878 q Mail a r: P.O. ox 830, Columbus FQ/ (2872 r Phone—(82 863-2736 www.plai th.org Email—i of @pla ath.org Secy-Treas.—Kathy aidaner 4/,V �S Principal —Gary Maldaner # Source 1 NC Manufacturers Register ✓` 2 Water Billiing Record 3 IndustrySelect (formerly EZ Select) 4 Sewer Connection Permit 5 Chamber of Commerce Roster etc. 6 Telephone Directory 7 Google Maps 8 9 10 Firefox https:Houtlook.live.com/mail/O/ From: Billing Clerk <billingclerk@tryonnc.gov> Sent: Thursday, April 13, 2023 9:15 AM To: debmbradley@hotmail.com <debmbrad ley@hotmail.com> Subject: industrial sewer Good morning Deborah, The only business that we have in the Town that dumps industrial waste is Tryon Finishing Corporation and that is the only business for the past 5 years as well. Let me know if you need any more information. Have a great day, Jordan McKeown Billing Clerk/ Tax Collector Town of Tryon 1 of 1 6/13/2023, 11:00 AM Home View Help v 0 'aT Delete 8 Archive C) Report <5' Sweep ep Move to Ref ° = Folders B Inbox 777 Junk Em... 300 Drafts 215 Sent Items ii Deleted Items 8 Archive Notes aS ED Conversatio... ED Dana Satter... El Debs Stuff D eDMR rec... 9 ED FOG 1 ED Gary Miliage r-) John Lassiter e] Jonathan H... CJ Kelley keenan M Land Applic... ED Nationwide ... e] Pretreatment X Close Previous Next Re: industrial sewer C! isBilling Clerk <billingclerk@tryonnc.gov> To: You Good morning Deborah, TRYON NEWS MEDIA LLC 16 N TRADE ST AVERAGE MONTHLY USAGE 2675 Yes, 69 Pacolet St is currently in the name of Bank of America, I do not have business name Andwin Scientific Inc. Have a great day, Jordan Mckeown From: Deborah Bradley <debmbradley@hotmail.com> Sent: Thursday, May 11, 2023 8:55 AM To: Billing Clerk <billingclerk@tryonnc.gov> Subject: Re: industrial sewer Good Morning Jordon, I have one more business I need average water usage for the Tryon Daily Bull I also noticed that Andwin Scientific, Inc. was listed as Bank of America - 69 P; Thanks, for all your help, Deborah From: Billing Clerk <billingclerk@tryonnc.gov> Sent: Tuesday, May 9, 2023 10:13 AM To: Deborah Bradley <debmbradley@hotmail.com> Subject: Re: industrial sewer I am basing this average off of the last 4 bills: ® Upgrade to Microsoft 365 with BANK OF AMERICA premium Outlook 69 Pacolet Street features 1525 gal 1 of 1 6/13/2023, 10:26 AM Mail - Deborah Bradley - Outlook https:Houtlook.live.com/mai]/O/inbox/id/AQMkADAwATY3ZmYA... u Home View Help 8 rn Folders B inbox 777 ep Junk Em... 301 Drafts 215 D Sent Items Deleted Items e Archive Notes 00 Conversatio... e7 Dana Satter... ED Debs Stuff L1 eDMR rec... 9 FOG 1 �] Gary Miliage e] John Lassiter Jonathan H... e3 Kelley keenan Land Applic... e] Nationwide ... Pretreatment Public Not... 1 Sewer Use ... State Retir... 2 l� State Stuff 5 Town Mana... e] Vacation ren... Create new f... Groups ® Upgrade to Microsoft 365 with premium Outlook features u Delete B Archive 0 Report — <�' Sweep r© Move to Reply / ICRead /Unread �i� C Close Previous Next Re: industrial sewer G° 0 Billing Clerk < bi Ili ngclerk@tryonnc.gov> (--� *-1 r> "' To: You Thu 5/11/2023 9:34 AM Good morning Deborah, TRYON NEWS MEDIA LLC 16 N TRADE ST AVERAGE MONTHLY USAGE 2675 Yes, 69 Pacolet St is currently in the name of Bank of America, I do not have any accounts under the business name Andwin Scientific Inc. Have a great day, Jordan Mckeown From: Deborah Bradley <debmbradley@hotmail.com> Sent: Thursday, May 11, 2023 8:55 AM To: Billing Clerk <billingclerk@tryonnc.gov> Subject: Re: industrial sewer Good Morning Jordon, I have one more business I need average water usage for the Tryon Daily Bulletin. I also noticed that Andwin Scientific, Inc. was listed as Bank of America - 69 Pacolet St. Thanks, for all your help, Deborah From: Billing Clerk <billingclerk@tryonnc.gov> Sent: Tuesday, May 9, 2023 10:13 AM To: Deborah Bradley <debmbrad ley@hotmail.com> Subject: Re: industrial sewer I am basing this average off of the last 4 bills: 69 Pacolet Street 1525 gal Gleason Pottery 35 Erskine Rd. Tryon, NC 700 gal Saluda Forge 73 Ola Mae Way Tryon, NC - 2825 gal Turner MFG. Co. Inc. 1081 S. Trade St. Tryon, N.C. 325 gal I Of I 6/13/2023, 10:29 AM Mail - Deborah Bradley - Outlook https://outlook.live.com/mail/O/inbox/id/AQMkADAwATY3ZmYA... v Home View Help V o� Folders B Inbox 777 Junk Em... 301 v 7% Drafts 215 1i Sent Items Deleted Items Archive Notes °oo Conversatio... Dana Satter... Debs Stuff E3 eDMR rec... 9 Cj FOG 1 n Gary Miliage e] John Lassiter lD Jonathan H... e] Kelley keenan C:) Land Applic... M Nationwide ... CD Pretreatment e] Public Not... 1 (!:) Sewer Use ... ED State Retir... 2 e] State Stuff 5 e] Town Mana... Vacation ren... Create new f Groups New group Delete - 8 Archive 0 Report `S�/ Sweep ep Move to � Reply E-) Read / Unread J C v Close Previous Next Re: industrial sewer L° 0 Billing Clerk <billingclerk@tryonnc.gov> (--` *` /4 "' To: You Thu 5/11/2023 9:34 AM Good morning Deborah, TRYON NEWS MEDIA LLC 16 N TRADE ST AVERAGE MONTHLY USAGE 2675 Yes, 69 Pacolet St is currently in the name of Bank of America, I do not have any accounts under the business name Andwin Scientific Inc. Have a great day, Jordan Mckeown From: Deborah Bradley <debmbrad ley@hotmail.com> Sent: Thursday, May 11, 2023 8:55 AM To: Billing Clerk <billingclerk@tryonnc.gov> Subject: Re: industrial sewer Good Morning Jordon, I have one more business I need average water usage for the Tryon Daily Bulletin. I also noticed that Andwin Scientific, Inc. was listed as Bank of America - 69 Pacolet St. Thanks, for all your help, Deborah From: Billing Clerk <billingclerk@tryonnc.gov> Sent: Tuesday, May 9, 2023 10:13 AM To: Deborah Bradley <debmbrad ley@hotmail.com> Subject: Re: industrial sewer I am basing this average off of the last 4 bills: BANK OF AMERICA 69 Pacolet Street 1525 gal Gleason Pottery 35 Erskine Rd. Tryon, NC 700 gal Saluda Forge 73 Ola Mae Way Tryon, NC 2825 gal Turner MFG. Co. Inc. 1081 S. Trade St. Tryon, N.C. 325 gal From: Deborah Bradley <debmbradley@hotmail.com> Sent: Tuesday, May 9, 2023 10:05 AM To: Billing Clerk <billingclerk@tryonnc.gov> Subject: Re: industrial sewer Thank you. I also need for each business listed below, except Cooper Studio there average monthly water usage. From: Billing Clerk <billingclerk@tryonnc.gov> Sent: Tuesday, May 9, 2023 9:13 AM To: Deborah Bradley <debmbradley@hotmail.com> Subject: Re: industrial sewer Good morning, ® Upgrade to Please see my responses below: Microsoft 365 with premium Outlook Andwin Scientific, Inc. features 69 Pacolet Street THIS ACCOIINT IS IINDFR RANK OF AMFRICAN RI IT IT IS ACTIVF ANn HAS SFWFR 1 of 1 6/13/2023, 10:32 AM Re: industrial sewer - Deborah Bradley - Outlook https://outlook.live.com/mail/O/inbox/id/AQMkADAwATY3ZmYA... 'iiT Delete 8 Archive (E) Report <---, Reply v 0 Read / Unread 0 Categorize - R Fla( v Re: industrial sewer J You replied on Thu 5/11/2023 8:55 AM 0Billing Clerk <billingclerk@tryonnc.gov> To: You I am basing this average off of the last 4 bills: BANK OF AMERICA 69 Pacolet Street 1525 gal Gleason Pottery 35 Erskine Rd. Tryon, NC 700 gal Saluda Forge 73 Ola Mae Way ---------------------------- Tryon, NC ---------------- 2825 gal Turner MFG. Co. Inc. 1081 S. Trade St. Tryon, N.C. 325 gal From: Deborah Bradley <debmbradley@hotmail.com> Sent: Tuesday, May 9, 2023 10:05 AM To: Billing Clerk <billingclerk@tryonnc.gov> Subject: Re: industrial sewer <---� «1 r-) ... Tue 5/9/2023 10:13 AM Thank you. I also need for each business listed below, except Cooper Studio there average monthly water usage. From: Billing Clerk <billingclerk@tryonnc.gov> Sent: Tuesday, May 9, 2023 9:13 AM To: Deborah Bradley <debmbradley@hotmail.com> Subject: Re: industrial sewer Good morning, Please see my responses below: Andwin Scientific, Inc. 69 Pacolet Street THIS ACCOUNT IS UNDER BANK OF AMERICAN BUT IT IS ACTIVE AND HAS SEWER Cooper Studio P.O. Box 11 Tryon, NC I DONT HAVE A BUSINESS NAME IN THE SOFTWARE FOR COOPER STUDIO, DO YOU KNOW WHAT THE PHYSICAL LOCATION IS? Gleason Pottery 35 Erskine Rd. 1 of 1 6/13/2023, 10:34 AM iws RECEIVED Checklist JUN 2 2 2023 NCDEQ/DWR/NPDES Approx Check if not Process or in service Check if No Check if other non- Why SIU area or not in Sewer Date long Domestic domestic Business Permit is Names business Service Date form Date of site form was Flow only flow Description Or isn't Industry X X was received visit received X (gpd) needed Tryon 5/15/23 5/15/23 Printing Has permit Finishing Cloth #001 Turner Mfg 5/11/23 5/11/23 X Sales No process water Saluda Forge 5/15/23 5/15/23 X Welding No W & S Service Andwin 5/11/23 X Distributor of No Process Scientific, Laboratory water Inc. microscopes Tryon Daily 5/11/23 5/11/23 X Newspaper No process Bulletin Publishing water Gleason 5/16/23 5/16/23 X Ceramic No process Pottery sculptures water Arledge X N/A No longer Printers In business Cooper X N/A No longer Studio In business Henson's inc. X N/A No W&S service. Business in SC Industrial Waste Survey Short Form This form has been sent to your business to determine types and sources of wastewater that are entering the _Mr U P 1,4 14- S Lt.l i eY P/ e:.jq-f This form must be completed `s (POTW Name) in accordance with section '/_1- B)of our Sewer Use Ordinance (NC Model Section 5.7). Our Sewer Use Ordinance can be examined during normal business hours at the address listed below. If you have ``any question or concerns while completing the form please contact ZC i 5rcf.d(aa:f (Pretreatmant Contact and Phone Number) Name of Business Address City/State/ZipCode-:-I—*n% /1 ( Telephone: �Sl - Sys �_ g,��-� Fax: Number of Employees S' What Standard Industrial Classification (SIC) Code(s) do you report under: Briefly describe your business include products manufactured or services performed Please list all water uses and approximate volume used in gallons per day for each use, including facility washdown water. Water Use Volume Used (gallons day) Process: .per Facility Washdown Domestic(bathrooms, cafeteria Total: Our Sewer Use Ordinance requires that an Authorized Representative of the User sign all reports to the Sewer Authority. Authorized Representative is defined as a Person responsible for Principle Business decisions or other policy decisions for the facility. To the Best of my owlel3ge the information on this form is true and accurate, Signature Date 5 Title ✓ pler k/ " q viti 54 Y- Return this form by to: (Wastewater Treatment Plant) (Street) (City/State/Zip) Failure to return this form is enforceable in accordance with the Sewer Use Ordinance. -uayici. IVY o vuMance Chapter Filename: Chi er 3 IWS Appendix er 3 Revision Date: September 1, 1993 Industrial Waste Survey Short Form This form has been sent to your business to determine types and sources of wastewater that are entering the Tr i 1 e r4 f i,ck�e,' PI 4.n1•[ This form must be completed (POTW Name) in accordance with section "/.4 )of our Sewer Use Ordinance (NC Model Section 5.7). Our Sewer Use Ordinance can be examined during normal business hours at the address listed below. If you have any question or concerns while completing the form please contact 13e rr,a rc (e:,t (Pretreatrn&t Contact and Phone Number) Name of Business I L,04/e Address 7l t-ad e S7`, City/State/Zip Code �rYo/L /J , C , 2$' 2 Telephone: '�ZZ'7 - ` -51 "9 2 V7 Fax: Y 2S (a Number of Employees What Standard Industrial Classification (SIC) Code(s) do you report under: 3 z z ,�3 7 - — — — — , ----- Briefly describe your business include products manufactured or services performed LA-1- --t S �C_- 14) Please list all water uses and approximate volume used in gallons per day for each use, including facility washdown water. Water Use Volume Used (gallons per day) Process: U Facility Washdown Domestic(bathrooms, cafeteria) / Total: Our Sewer Use Ordinance requires that an Authorized Representative of the User sign all reports to the Sewer Authority. Authorized Representative is defined as a Person responsible for Principle Business decisions or other policy decisions for the facility. To the Best of my knowledge the information on this form is true and accurate, Signature Date �1 2 Title `' W AJ % Return this form by to: (Wastewater Treatment Plant) (Street) (City/State/Zip) Failure to return this form is enforceable in accordance with the Sewer Use Ordinance. Chapter: IWS Guidance Chapter 3 Filename: Chi IWS Appendix 3-A Revision Date: September 1, 1993 Industrial Waste Survey Short Form This form has been sent to your business to determine types and sources of wastewater that are entering the Tryon Wastewater Treatment Plant. This form must be completed (POTW Name) in accordance with section 51.64 B of our Sewer Use Ordinance (NC Model Section 5.7). Our Sewer Use Ordinance can be examined during normal business hours at the address listed below. If you have any question or concerns while completing the form please contact: Deborah Bradley (828) 817-9516 Name of Business Address City/State/Zip Code % U�/✓ /V�' Telephone:;, - - �S �/'�13� 7 Fax: Number of Employees / What Standard Industrial Classification (SIC) Code(s) do you report under: _a -Z A 2, ---- , ---- , --- Briefly describe your business include products manufactured or services performed ,.�,,,.�►7�`..,,;,.,/i �i�ir��.laJy� . �G%� O1�.L[.G C. �KC��XQD Please list all water uses and approximate volume used in gallons per day for each use, including facility washdown water. Water Use Volume Used (gallons per day) Process: Facility Washdown Domestic(bathrooms; cafeteria) a Total: Our Sewer Use Ordinance requires that an Authorized Representative of the User sign all reports to the Sewer Authority. Authorized Representative is defined as a Person responsible for Principle Business decisions or other policy decisions for the facility. To the Bed of my knowle ge�the information on this form is true and accurate, Title Return this form within 30 days to: (Wastewater Treatment Plant) (Street) (City/StatdZIP) Failure to return this form is enforceable in accordance with the Sewer Use Ordinance. IWS Short Form Filename: IWS Short Form Revision Date: September 1, 1993 Industrial Waste Survey Short Form This form has been sent to your business to determine types and sources of wastewater that are entering the -rr i l o tJ 1j%5 fc.u7C. t✓ P/ li rJ f This form must be completed (POTW Name) in accordance with section /.4 g)of our Sewer Use Ordinance (NC Model Section 5.7). Our Sewer Use Ordinance can be examined during normal business hours at the address listed below. If you have any question or concerns while completing the form please contact (PretreatmAnt Contact and Phone Number) Name of Business Address City/State/Zip Code r an/, n%. L 3 9 7S'2- Telephone: r 228) 91::0-4-996 Fax: Number of Employees S What Standard Industrial Classification (SIC) Code(s) do you report under: Asr 04 9 Briefly describe your business include products manufactured or services performed Please list all water uses and approximate volume used in gallons per day for each use, including facility washdown water. Water Use Volume Used (gallons per day) Process: Facility Washdown Domestic bathrooms, cafeteria Lj Total: Our Sewer Use Ordinance requires that an Authorized Representative of the User sign all reports to the Sewer Authority. Authorized Representative is defined as a Person responsible for Principle Business decisions or other policy decisions for the facility. �To the B st of r31y lrnowledge formation onthis form is a and accurate, Signature }Jute 2 I Title xeturn tms Corm oy to: (Wastewater Treatment Plant) (Street) (City/State/Zip) Failure to return this form is enforceable in accordance with the Sewer Use Ordinance. Chapter: IWS Guidance Chapter 3 Filename: Ch3 IWS Appendix 3-A Revision Date: September 1, 1993 Industrial Waste Survey Short Form This form has been sent to your business to determine types and sources of wastewater that are entering the Tr u a �f 1�% s tc,t,elefu- P/ tc N•1t . This form must be completed (POTW Name) in accordance with section)°f our Sewer Use Ordinance (NC Model Section 5.7). Our Sewer Use Ordinance can be examined during normal business hours at the address listed below. If you have any question or concerns while completing the form please contact (Pretreatm4nt Contact and Phone Number) Name of Business Address City/State/Zip Code Telephone: Number of Employees What Standard Industrial Classification (SIC) Code(s) do you report under: Briefly describe your business include products manufactured or services performed Please list all water uses and approximate volume used in gallons per day for each use, including facility washdown water. Water Use Volume Used (gallons r day) Process: Facility Washdown Domestic(bathrooms, cafeteria 9S Total: Our Sewer Use Ordinance requires that to the Sewer Authority. Authorized Principle Business decisons or other p' To the Best of Signature Title l Representative of the User sign all reports! e is defined as a Person responsible for for the facility. on this form is true and accurate, Dat �' ` / Return this form by to: 1 !'tionJ in> 77r-' (Wa tewater Treatment Plant) 3v / W Tac/ (street) gQ,N1 AIL Ag79'Z (CityState/Zip) Failure to return this form is enforceable in accordance with the Sewer Use Ordinance. Chapter: IWS Guidance Chapter 3 Filename: Chi 1WS Appendix 3-A Revision Date: September 1, 1993 Firefox about:blank Industrial Waste Survey Short Form This form has been sent to your business to determine types and sources of wastewater that are entering the `Tr u n r4 ukfe.r P1 "4 This form must be completed (POTW Name) in accordance with sectionSj.4CB)of our Sewer Use Ordinance (NC Model Section 5.7). Our Sewer Use Ordinance can be examined during normal business hours at the address listed below. If you have any question or concerns while completing the form please contact ZC61M ?�-r ip e (Pretreatm&t Contact and Phone Number) t Name of Business _ TV 1°'^ Address eL.So 5 c-reve— ?-oc, J City/State/Zip Code -Try -9 ^ la L 'tom 15 -L- Telephone: �'2,8 -`d -S 1 Fax: "t Number of Employees `two What Standard Industrial Classification (SIC) Code(s) do you report under: 2 Z(o n. z z(0 1 > — — — — - ---- Briefly describe your business include products manufactured or services performed N, n +LGlj� Ir t, �5 k of- w �,.. cl.. t VY �l � ` VvPN>i 7�CiV:� Please list all water uses and approximate volume used in gallons per day for each use, 1 din f '1' hdown water Inc u gact t was Water Use Volume Used (gallons er day) Process: er2-2� 5 �v� ✓v1 3'0 t.000 W a5�• G�LG.�� r' tL� t �cv FacilityWashdown S'.000 Domestic(bathrooms, cafeteria 1 �000 Total: 7 f t o o� Our Sewer Use Ordinance requires that an Authorized Representative of the User sign all reports'. to the Sewer Authority. Authorized Representative is defined as a Person responsible fori Principle Business decisions or other policy decisions for the facility. To the Best of y led a th information on this form is true and accurate, Signature kn Date '5- 1 ;1 1 Z Title f vc ' , Return this form by to: (Wastewater Treatment Plant) (Street) (City/stateJzip) Failure to return this form is enforceable in accordance with the Sewer Use Ordinance. Chapter: IWS Guidance Chapter 3 Filename: Chi IWS Appendix 3-A Revision Date: September 1, 1993 I Firefox about:blank Industrial User Wastewater Survey & Permit Application COVER PAGE Company Name: Tryon Finishing Corporation Name of responsible person on site at the facility authorized to represent the Name of alternative on site person familiar with the day to day operations, company in official dealings with the Sewer Authority and/or the City. environmental permitting requirements, monitoring, record keeping, and data Naiden Kremenliev management. James Bradlev Title President Years with firm 3 Title Director of Manufacturing Years with firm 3 Phone # 828-859-5891 Fax # Phone # 828-859-5891 Fax # Physical street address of facility Official mailing address, if different. Note if same. 250 Screvens Road City Tryon State NC Zip 28782 City State Zip The information provided by you on this questionnaire serves two functions: The information is used to determine if your facility needs an Industrial User Pretreatment Permit (IUP) for the discharge of wastewater to the local sewer. 2. If an Industrial User Pretreatment Permit (IUP) is required, this survey serves as the application for an Industrial User Pretreatment Permit (IUP). Requests for confidential treatment of information provided on this form shall be governed by procedures specified in 40 CFR Part 2. In accordance with Title 40 of the Code of Federal Regulations Part 403, Section 403.14 and the Local Sewer Use Ordinance (SUO), information and data provided in this questionnaire which identifies the content, volume and frequency of discharge shall be available to the public without restriction. This is to be signed by an authorized official of your firm, as defined in the Local Sewer Use Ordinance or the NC Model Sewer Use Ordinance, Section 1.2, after completion of this form. I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based upon my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false infortnati , in u . g t possibility of fine and/or imprisonment for knowing violations. June 6, 2023 Signature of Authorized Representative Date listed above (seal if Title: III wastewater Survey & Permit Application File name: https://ttyonfnishing-my.sharepointeom/pmonai/miden_tryonfinishing_com/Documents/Licenses and Permits/Town of Tryon/Industrial Wastewater Survey & IUP Permit Application (Long Form) - 06.06.23.docx Revision date: 12/30/97 Page I of 198 1 of 21 6/12/2023, 9:24 AM Firefox about:blank Industrial User Wastewater Survey & Permit Application 1. Provide a brief narrative description of the type of business, manufacturing processes, or service activities your firm conducts at this site. Printing of cloth — most of which is used to manufacture bandannas 2. List the primary products produced at this facility: Printed cloth List raw materials and process additives used: Cotton and polyester/cotton cloth Dyes, bleach, salt, caustic, hydrogen peroxide, acetic acid, softeners 4. Are biocides added to any water discharged to the POTW, if yes describe: Yes No X Describe weekly production schedule, including shifts worked per day, employees per shift, and primary operation during shift. 1 shift per day, 10 hours, 4 days/week. 22 employees total 6. Production process is: Check, if all continuous Check, if all batch x If both please enter, % continuous = % % Batch = % Title: IU Wastewater Sun-ey & Pemut Application File name: httpsl-tryonfinishmLy-my.sharepointcom- rsonaUnaiden_trymfim hiog_com/Documents✓Licenses and Permits/Town I— - I . - I — n n TT iT . • 1. • IT — \ ^e nI n• 1 2 of 21 6/12/2023, 9:24 AM Firefox about:blank of tryon/mausmal wastewater burvey & iur rertmi Application kLong rorm) - Vo.uo./s.aocx Revision date: 12/30/97 Page 2 of 198 Industrial User Wastewater Survey & Permit Application 7. Does production vary significantly (+- 20 %) by season. Describe. Yes No x 8. Are any significant (+- 20 %) changes in production that will affect wastewater discharge expected in the next 5 years. If yes, please describe. Yes No x 9. List all current waste haulers. Give name, address, phone numbers. volume and materials hauled off. GFL Environmental PO Box 791519 Baltimore, MD 21279 864-269-1065 10. Attach a copy of laboratory analyses performed in the last year on the wastewater discharge(s) from your facilities. Summarize data on the attached Data Summary Form. See lab reports from July 2022 to April 2023 11. Attach sketch or schematic showing sampling points and all connections to the sewer. See attached 12. Complete the Wastewater Pollutants Checklist attached to this Survey. See checklist Title: N Wastewater survey & Permit Application File name: https:// ryonsnishing_my..h.,,p.int. ✓pets.n.y..ide. tryonfinish;ng_com/Documents/Licenses and Permits/Town rm n t t ��• . n n >7m t1 . • r . it• r. ♦ ni n� n.t t 3 of 21 6/12/2023, 9:24 AM Firefox about:blank or iryowmaustmi wastewater burvey & iur rermit Application kLong rorm) - uo.uo.,z3.aocx Revision date: 12/30/97 Page 3 of 198 Industrial User Wastewater Survey & Permit Application 13. Do you have, or have you ever applied for, been issued, or been denied an NPDES permit to discharge to the surface waters or storm sewers of North Carolina? If yes, list all other NPDES permits, permit numbers, dates, and names used to apply for them, or reason denied. If yes: Permit , #, date, applicant name NCO049305 July 1, 2020 Tryon Finishing Corporation If yes: Permit , #, date, applicant name Yes No 14. Do you have, or have you ever applied for or been issued an Industrial User Pretreatment Permit (IUP) to discharge wastewater to the sewer collection system. If yes, list all other IUP permits, permit numbers, dates, _ and names used to apply for them. if yes: Permit , #, date, applicant name #001 January 1, 2022 Tryon Finishing Corporation If yes: Permit, #, date, applicant name Yes x No 15. Do you have, or have you ever applied for or been issued any other Environmental Permits (for example; air, RCRA, groundwater, stormwater, general, Non -Discharge, septic tank, etc.). If yes, list all other permits, permit numbers, dates and names used to apply for them. If Yes: Permit type, #, date, applicant name Air Permit # 03977RIO October 15, 202 Tryon Finishing Corporation if yea: Permit type, #, date, applicant name if yes: Permit type, #, date, applicant name Yes x No 16. Is a Spill Prevention Control and Countermeasure (SPCC) Plan prepared for this facility? Yes No X 17. Is a Spill /Slug Control Plan required by the POTW, prepared for this facility? Yes No Y Title: IU Wasteurater Surrey & Permit Application File name: httpsJ/tryonfmshmg-my.sharepointcom'penonaL,naiden_tryonf.&.g_Com/Documents/Licenses and Permits/Town r- n 1 . • I •tf . . n n rim T . • 1. . it r \ A/ AI - 1 4 of 21 6/12/2023, 9:24 AM Firefox about:blank of lryon/inaustriai wastewater )urvey & iur rermlt application tL.ong rorm/ - uo.uo.2-s.(locx Revision date: 12/30/97 Page 4 of 198 Industrial User Wastewater Survey & Permit Application 18. Do you have any underground storage tanks at your facility? If yes, list contents and volume of each tank. 19. Do you have any above ground storage tanks at your facility? If yes, for each tank, list the contents, volume, whether the tank has any spill prevention or containment devices, such as dikes, and procedures for draining any containment devices. #1 Oil 10,000 Gal Containment —No longer in use #2 Oil 10,000 Gal Containment — No longer in use #3 Diesel 2,000 Gal — No longer in use #4 Poh•mer 4,000 Gal - No longer in use #5 Kerosene 300 Gal - No longer in use #6 Peroxide 3,000 Gal - No longer in use #7 Peroxide 3,000 Gal - No longer in use #8 Caustic 5,000 Gal - No longer in use #9 Hot Rater 20,000 Gal - No longer in use #10 Hot Water 4,000 Gal - No longer in use #11 Liquid wax 3,000 Gal - No longer in use #12 Liquid Wax 3,000 Gal - No longer in use Yes No X Yes # of Tanks 12 No RECEIVED JUN � 2 �M NCDEQ/DWR/NPDES Title: M Wastewater Survey & Permit Application File name: https)/tryonfinishing-my.sharepointcom'personal/naiden_tryonfmishing_com%Documents/Licenses and Permlts/Town 5 of 21 6/12/2023, 9:24 AM Industrial User Wastewater Survey & Permit Application PART II, Water Supply, Use, & Disposal Worksheet: 2. 3. 4. 5. 6. 8. 9. Water Used for: Water Source(s) Avg. gal/day Max. gal/day M a a s u re d E st i In at a d Disposal Method(s) Avg. gal/day Max. gal/day M a a s u re d E St i In at e d Process water Washdown water Water into product Air Quality Permitted units Domestic - toilets, drinking, cafe Cooling water, Process NON -Contact Boiler / Cooling tower blowdown Cooling water, HVAC Other: (see Source List below) (see Disposal List below) 4/1 30,000 40,000 1 30,000 40,000 4/1 500 2,000 1 500 2,000 4/1 1,500 3,000 5/10 1,500 3,000 1 1,000 2,000 2 City Water 1,000 2,000 4/1 2,500 5,000 1 Basin 2,500 5,000 4/1 500 1,000 5/1 Basin 500 1,000 Evaporation Storm Water Runoff Totals => 36,000 53,000 Totals =>I 369000 53,000 Typical Water Sources: Possible Water Disposal Methods 1. City / Public supply 1. Sanitary sewer, with pretreatment 2. Private wells, drinking 2. Sanitary sewer, without pretreatment 3. Groundwater remediation wells 3. Storm sewer 4. Private ponds 4. Surface waters of NC 5. Surface waters of NC, please identify 5. Evaporation & Include others if applicable 6. Land applied 7. To groundwater 8. Septic Tank 9. Waste Haulers (identify) Tide: IU Wastewater Survey & Permit Application File name: https://tryonfinishing-my.sharepoint.com/personal/naiden_tryonsnishing_com/Documents/Licenses and Permitsfrown of Tryon/Industrial Wastewater Survey & IUP Permit Application (Long Form) - 06.06.23.docx Revision date: 12/30/97 Page 6 of 198 10. Water into Product Title: Iil Wastewater Survey & Permit Application Filename: https:/,tyonfuiishing-my.gha l int.c m/personai/naidep_tryonfnishing_com/Documents/Licenses and Permits/Town of Tryon/Indu; IUP Permit Application (Long Form) - 06.06.23.docx Recision date: 12/30/97 Page 7 of 198 7 of21 6/12/2023, 9:24 AM PART III, PRETREATMENT FACILITIES: Are there any pretreatment devices or processes used for treating wastewater before being discharged to the sewer? Check all that are present, and describe. No pretreatment facilities => Flow equalization Aerated equalization => NON -Aerated equalization => X Total volume of equalization (million gal.) => 0.66 2. Activated Carbon Yes 3. Activated Sludge Yes 4. Air Stripping Yes 5. Centrifugation Yes 6. Chemical Precipitation Yes 7. Chlorination Yes 8. Cyanide Destruction Yes 9. Cyclone Yes 10. Dissolved Air Floatation Yes 11. Filtration Yes 12. Flocculation Yes 13. Grease Trap Yes 14. Grit Removal Yes 15. Ion Exchange Yes 16. Neutralize, pH adjust Yes 17. Other Biological Treatment Yes 18. Ozonation Yes 19. Reverse Osmosis Yes 20. Screening Yes 21. Sedimentation Yes 22. Septic Tank Yes 23. Silver Recovery Yes 24. Solvent Separation Yes 25. Spill protection Yes List any others. No No No No No No No No No No No No No No No No No No No No No No No No X Describe any, if present. X X X X X X X X X X X X X X X X X X X X X X X pH and Flow Monitoring - YES Title: IU wastewater Survey R Petmit Application File name: https:/,Iryonsni4iing-my.sharepoint_c4Dm-personatnai&t tryonfnishing—corr/Documents/Licenses and Permits/Town of Tryon/Industrial Wastewater Survey & IUP Permit Application (Long Form) - 06.06.23.docx Revision date: 12/30/97 Page 8 of 198 8 of 21 6/12/2023, 9:24 AM Firefox about:blank PART IV, CATEGORICAL INFORMATION: When were operations started at this facility Facility start up date 1957 2. List all Standard Industrial Classification (SIC) codes for your facility. These may be found on State Unemployment forms, tax forms, accounting records, or from the Chamber of Commerce. 2269 2261 3. Has this facility ever been considered a Categorical Industrial User (CIU) as described by the Code of Federal Regulations (40 CFR)? If yes, give complete 40 CFR number => No 4. Are any other facilities owned and/or operated by your company permitted as Categorical Industrial Users (CIUs) as described by the Code of Federal Regulations (40 CFR)? If yes please give name(s), location, and 40 CFR number. Yes No Title: lU Wastewater Surrey & Permit Application File name: httpslilryoafnishing-my.sharepoint.com personal naiden_tryonfuushing_COm/Documents/Licenses and Permits/Town r — 1T I . . 9 Tf r n n iT ♦T T • 1. . /T — \ — — — 1 9 of 21 6/ 12/2023, 9:24 AM Firefox about:blank or iryowmaustriai wastewater aurvey & iur rermlt Application 1Long rorml - uo.uo.Ls.aocx Revision date: 12/30/97 Paee 9 of 198 PART IV, CATEGORICAL INFORMATION: (continued) 5. Check any activities listed below that are performed at your facility: Check below 40 CFR# I Industrial Activity Check I below 40 CFR# Industrial Activity 467 Aluminum Forming 427 Asbestos Manufacturing 461 Battery Manufacturing 431 Builders paper & board mills 407 Canned & preserved fruits & veg. 408 Canned & preserved seafood 458 Carbon black Manufacturing 411 Cement Manufacturing 437 Centralized Waste Treatment 434 Coal Mining 465 Coil Coating 468 Copper Forming 405 Dairy products processing 469 Electrical, electronic components 413 Electroplating 457 Explosives Manufacturing 412 Feedlots 424 Ferro allay Manufacturing 418 Fertilizer Manufacturing 464 Foundries, Metal Mold & Casting 426 Glass Manufacturing 406 Grain mills 454 Gum & Wood Chemicals Mfg. 460 Hospitals 447 Ink formulating 415 Inorganic chemical Manufacturing 420 Iron & Steel Manufacturing 425 Leather Tanning & Finishing 432 Meat products 433 Metal finishing 464 Metal molding and casting 436 Mineral mining and processing 471 Nonferrous Metal, Form & Powders 421 Nonferrous Metals Manufacturing 414 OCPSF, Organic Chemicals, Plastics, & Synthetic Fiber Manufacturing 435 Oil & gas extraction 440 Ore mining and dressing 446 Paint formulating 443 Paving and roofing materials Mfg. 455 Pesticide Manufacturing 419 Petroleum Refining 439 Pharmaceutical Manufacturing 422 Phosphate Manufacturing 459 Photographic supplies 463 Plastics molding and forming 466 Porcelain enameling 430 Pulp, paper, and paperboard 428 Rubber Manufacturing 417 Soap & Detergent Manufacturing 423 Steam Electric power Generation 409 Sugar processing 410 Textile Mills 429 Timber products processing 442 Transportation Equipment Cleaning Others X Title: IU Wastewater survey & Permit Application Filename: https://tryonfnidimg-my.sharepoint.com/pm n,n at/md_tryon�,;shmg_com/Documents/Licenses and Permits/Town 10 of21 6/12/2023, 9:24 AM or iryotvinaustrlai wastewater purvey & iur rermll Application (Long rorm) - uo.uo.2-i.aocx Revision date: 12/30.97 Page 10 of 198 Wastewater Pollutant Checklist Chemical Name EPA Check if Check if Check if Check if Concentration Storet Present at Absent at Present in Absent in in Discharge, Code Facility Facility Discharge Discharge if Known (m 1) Acid Extractable Or anics 2-Chloro henol 34586 2 4-Dichloro henol 34601 2 4-Dimeth 1 henol 34606 4-Dinitro henol 34616 2-Meth 1-4 6-dinitro henol 34657 4-Chloro-3-meth 1 henol 34452 2-Nitro henol 34591 4-Nitrot3henol 34646 Pentachloro henol 39032 Phenol 34694 x' 2A, 6-Trichloro henol 34621 Race Neutral Oroanics 1 2 4-Triclilorobenzene 34551 1 2-Dichlorobenzene 34536 1 2-Di hen lh drazine 34346 1 3-Dichlorobenzene 34566 1 4-Dichlorobenzene 34571 2 4-Dinitrotoluene 34611 2 6-Dinitrotoluene 34626 2-Chloronaphthalene 34581 X X 3,3-Dichlorobenzidine 34631 X X 4-Bromophenyl phenyl ether 34636 X X 4-Chlorophenyl phenyl ether 34641 X X Acenaphthene 03405 x X Acenaphthylene 34200 x X Anthracene 34220 h X Benzidine 39120 X X Benzo (a) anthracene 34526 h X Benzo (a) pyrene 34247 X X Benzo (b) fluoranthene 34230 X X Benzo (ghi) perylene 34521 X Y Benzo (k) fluoranthene 34242 X X Bis(2-chloroethoxy) methane 34278 Y X Bis(2-chloroethyl) ether 34273 X X Bis(2-chloroisopropyl) ether 34283 X X Bis(2-ethylhexyl) phthalate 39100 X X Butyl benzyl phthalate 34292 X X Chrysene 34320 X X Di-n-butyl phthalate 39110 X X Title: IU Wastewater Survey & Permit Application File name: httpsJ/tryonfimshmg-my.sharepoint.comlp,.m vnaiden tryonfuisbing_con /Documents/Licenses and Permits/Town r m rr t � �t r n n �r rr� r . �• it r-. � i. i n s .... � I of21 6/12/2023, 9:24 AM or iryori/maustrlai wastewater purvey & iur rermu Application kLong rorinl - uo.uo./s.aocx Recision date: 12/30/97 Page 11 of 198 Wastewater Pollutant Checklist Chemical Name EPA Check if Check if Check if Check if Concentration Storet Present at Absent at Present in Absent in in Discharge, Code Facility Facility Discharge Discharge if Known (m 1) Base Neutral Organics (continued) Di-n-octyl phthalate 34596 X X Dibenzo (a,h) anthracene 34556 X X Diethyl phthalate 34336 X X Dimeth 1 plithalate 34341 X X Fluoranthene 34376 X X Fluorene 34381 X X Hexachlorobenzene 39700 X x Hexachlorobutadiene 34391 X X Hexachloroc clo entadiene 34386 X X Hexachloroethane 34396 X X Indeno(1,2,3-cd) pyrene 34403 X X Iso horone 34408 X X N-nitroso-di-n- ro lamine 34428 X X N-nitrosodimeth lamine 34438 X X N-nitrosodi hen lamine 34433 X X Naphthalene 34696 X X Nitrobenzene 34447 X X Phenanthrene 34461 X X P rene 34469 X X Metals Aluminum 01104 X X Antimony 01097 X X Arsenic 01002 X X Beryllium 01012 X X Cadmium 01027 X X Chromium 01034 X X Copper 01042 X X 0.045 Lead 01051 X X Mercury 71900 X X Molybdenum 01062 X X Nickel 01067 X X Selenium 01147 X X Silver 01077 X X Thalium 00982 X I X Zinc 01092 X X 1 0.052 Title: rU Wastevmter Survey & Pemut Application File name: https://tzyonfinishing-my.sharepoint eom/pe wmUnaidea_uyonfinish* com/Documents/Licenses and Permits/Town rm n . . •ter `. n rr rr. � . .• . it r � ni i.i .... 12 of21 6/12/2023, 9:24 AM Firefox abouvblank of tryorvulaustrlai wastewater aurvey & iur rermu Application tLong rorm) - uo.uo.zs.aocx Revision date: 12/30/97 Page 12 of 198 Wastewater Pollutant Checklist Chemical Name EPA Check if Check if Check if Check if Concentration Storet Present at Absent at Present in Absent in in Discharge, Code Facility Facility Discharge Discharge if Known (mg/1) Other Inorganics Barium 01007 Chloride 00940 Cyanide 00720 Fluoride 00951 Purgeable Volatile Organics 1 1 1-Trichloroethane 34506 1 1 2 2-Tetrachloroethane 34516 1 1 2-Trichloroethane 34511 1 1-Dichloroethane 34496 1 1-Dichloroeth lene 34501 1 2-Dichloroethane 34531 1 2-Dichloro ro ane 34541 2-Chloroeth 1 vinyl ether 34576 Acrolein 34210 Acrylonitrile 34215 Benzene 34030 Bromodichloromethane 32101 Bromofonn 32104 Bromomethane 34413 Carbon tetrachloride 32102 Chlorobenzene 34301 Chloroethane 34311 Chloroform 32106 Chloromethane 34418 cis 1 3-Dichloro ro ene 34704 Dibromochloromethane 32105 Eth lbenzene 34371 Methylene chloride 34423 Tetrachloroeth lene 34475 Toluene 34010 trans 1 3-Dichloro ro ene 34699 trans-1 2-Dichloroeth lene 3asa6 Trichloroeth lene 39180 Trichlorofluoromethane 34488 Vinyl chloride 39175 Others Xylene X X Title: IU Wastewater Survey & Permit Application File name: httpsJ/hyonSnishmg-my.sharepoint_comp,,mai/naiden tryonfimd ing_com/Documents/Licenses and Permits/Town r-r it t . r — . - n -- s. . . 1. . it r 1 ni ni n1 t 13 of21 6/12/2023, 9:24 AM Data Summary Form Town of Tryon <= Receiving POTW NCO021601 <= Receiving NPDES # Equalization Basin 001 i.e., Give IU Name, IUP#, and/or pipe# Lab => Laboratory performing analysis => MDL => Laboratory Method Detection Limits => Notes => Notes => Q = Flow BOD TSS Ammonia ETS 2.0 mg/L Conc. Results from Lab <? mg/I ETS 50 mg/L Conc. Results from Lab <? mg/I Conc. Results from Lab <? mg/I Sample ID, or Count Date Sample Collected Notes about Sample M = Metered E = Estimated mgd gal/day 1 7/12/22 M 210 72 2 10/25/22 M 63 56 3 1/11/23 NI 200 4.6 4 3/15/23 M 5 4/12/23 M 12 1 93 6 7 8 9 10 I 12 etc TNS — Total number of samples => 4 4 Max. value => Maximum data value (mg/1) => 210 93 Avg. (use 1/2 BDL) => Avg. data value, Include BDL values as 1/2 detection limit => 56.4 Title: R1 Wastewater Survey & Permit Application File name: htrps://tryonfinishing-my.sharepoint.Qom/persmal/naiden_trymfinishing_com/Documents/Licenses and Permits/Town of Tryon/Industrial Wastewater Survey & IUP Permit Application (Long Form) - 06.06.23.docx Revision daze: 12/30/97 Page 14 of 198 Data Summary Form Town of Tryon <= Receiving POTW NCO021601 <= Receiving NPDES # Equalization Basin 001 <= Specific Sample Location! i.e., Give IU Name, IUP#, and/or pipe # Lab => MDL => Notes => Arsenic Copper Chromium Cadmium COD Copper ETS 0.01 mg/L Cone. Results from Lab <? mg/I ETS 0.001 mg/L Cone. Results from Lab <? mg/I ETS 0.005 mg/L Cone. Results from Lab <? mg/I ETS 0.001 mg/L Cone. Results from Lab <? mg/1 Cone. Results from Lab <? mg/1 Cone. Results from Lab <? mg/I Sample ID or Count Date Sample Collected 1 7/12/22 0.455 2 10/25/22 0.297 3 1111/23 0.0139 4 3/15/23 <1 0.001 0.001 < 0.001 5 4/12/23 0.28 6 7 8 9 10 11 12 etc TNS => 1 1 Max. Value => <0.001 0.455 0.001 <0.001 Title: lUWastewater Survey & Permit Application File name: https:/Aryonfinishing-my.sharepointcom/personal/naiden_tryonfinishing_com/Documents/Llcenses and Permits/Town of Tryon/Industrial Wastewater Survey & IUP Permit Application (Long Form) - 06.06.23.docx Revision date: 12/30/97 Page 15 of 198 Avg. (use1/2 BDL) => 0 0.261 1 -1 1 Data Summary Form Town of Tryon <= Receiving POTW NCO021601 <= Receiving NPDES # Equalization Basin 001 <= Specific Sample Location! i.e., Give IU Name, IUP#, and/or pipe # Lab — MDL => Notes => Cyanide Lead Mercury Nickel Silver Zinc Conc. Results from Lab <? mg/l ETS 0.05 mg/L Conc. Results from Lab <? mg/1 ETS 0.0002 mg/L Conc. Results from Lab <? mg/l ETS 0.01 mg/L Conc. Results from Lab <? mg/1 ETS 0.005 mg/L Conc. Results from Lab <? mg/l ETS 0.01 mg/L Conc. Results from Lab <? mg/l Sample ID or Count Date Sample Collected 1 7/12/22 < 0.0002 0.082 2 10/25/22 < 0.0002 1 0.042 3 1/11/23 <1 0.0002 0.082 4 3/15/23 <1 0.005 0.001 0.002 < 0.001 5 4/12/23 0.0006 0.093 7 x y 10 11 12 etc TNS=> 0 � ® F— 0 Tide- fU Wastewater Survey & Permit Application File name: haps:/hryonfinishing-my.sharepoint.com/personal/naiden_tryonfinishing_COm/DOcuments/Licenses and Permits/Town Of Tryon/industrial Wastewater Survey & IUP Permit Application (Long Form) - 06.06.23.docx Revision date: 12/30/97 Page 16 of 198 Max. Value => <.005 0.001 0.0006 0.002 <0.001 0.093 Avg. (usel/2 BDL) => �-100-005 0.001 0.0003 0.002 <0.001 1 0.075 Data Summary Form Town of Tryon <= Receiving POTW NCO021601 <= Receiving NPDES # Equalization Basin 001 <= Specific Sample Location! i.e., Give IU Name, IUP#, and/or pipe # Phosphorus Other Other Other Other Other Lab => MDL => Notes => ETS 0.02 mg/L Conc. Results from Lab <? mg/l Conc. Results from Lab <? mg/I Conc. Results from Lab <'? mg/I Cone. Results from Lab <? mg/l Conc. Results from Lab <? mg/l Conc. Results from Lab <? mg/l Sample ID or Count Date Sample Collected 1 7/12/22 10/25/22 3 1/11/23 4 3/15/23 1.21 5 4/12/23 6 7 8 9 10 11 12 etc Title: N Wastewater Survey & Permit Application File name: https://tryonfinishing-my.shmepoint.com/personal/naiden_tryonfinishing_COM/DOCuments/Licenses and Permits/Town Of Tryon/Industrial Wastewater Survey & IUP Permit Application (Long Form) - 06.06.23.docx Revision date: 12/30/97 Page 17 of 198 TNS => 1 Max. Value => 1.21 Avg. (use1/2 BDL) => 1.21 Tide: W Wastewater Survey & Permit Application File name: htips://tryonsnishing-my.sharepoint.Qom/personal/naiden_nyonsnishing_com/Documents/Licenses and Permits/Town of Tryon/Industrial Wastewater Survey & IUP Permit Application (Long Form) - 06.06.23.docx Revision date: 12/30/97 Page 18 of 198 Industrial User Wastewater Survey & Permit Application Part V, Waste Reduction Information : State Pretreatment Rule 15A NCAC 211.0916 (c)(1)(M) requires Significant Industrial Users to include a description of current and projected waste reduction (pollution prevention) activities. The codes listed are standard EPA codes found on Toxic Release Inventory and other environmental forms. Please check all applicable codes for your facility related to wastewater discharge. Current Projected Code Description W 13 Improved maintenance scheduling recordkee in , or procedures W 14 Changed production schedule to minimize equipment and feedstock changeovers W 19 Other changes in operating ractices (explain briefly in comments) W21 Instituted procedures to ensure that materials do not stay in inventory beyond shelf -life W22 Began to test outdated material -continue to use if still effective W23 Eliminated shelf -life requirements for stable materials W24 Instituted better labeling procedures W25 Instituted clearinghouse to exchange materials that would otherwise be discarded W29 Other changes in Inventory control (explain briefly in comments W31 1 Improved storage or stacking procedures W32 Improved procedures for loading, unloading and transfer operations W33 Installed overflow alarms or automatic shutoff valves W34 Installed secondary containment W35 Installed vapor recovery systems W36 Implemented inspection or monitoring program of potential spill or leak sources W39 Others ill and leak prevention (explain briefly in comments) W41 Increased purity of raw materials W42 Substituted raw materials W49 Other raw material modifications (explain briefly in comments) W51 Instituted recirculation within a process Title: N waste- ater Survey & permit Application File name: https:/,+hyoufmishing-my_sharepoint.com/personatinaiden_tryonfmishing_com/Documents/Licenses and Permits/Town of Tryon/Industrial Wastewater Survey & IUP Permit Application (Long Form) - 06.06.23.doex Revision date: 12/30/97 Page 19 of 18 19 of 21 6/12/2023, 9:24 AM Firefox about:blank Industrial User Wastewater Survey & Permit Application Current Projected Code Description W52 Modified equipment, layout, or piping W53 Use of a different process catalyst W54 Instituted better controls on operating bulk containers to minimize discarding of empty containers W55 Changed from small volume containers to bulk containers to minimize discarding of empty containers W58 Other process modifications (explain briefly in comments) W59 Modified stripping / cleaning equipment W60 Changed to mechanical stripping / cleaning devices (from solvents or other materials) W61 Changed to aqueous cleaners ( from solvents or other materials) W62 Reduced the number of solvents used to make waste more amenable to recycling W63 Modified containment procedures for cleaning units W64 Improved draining procedures W65 Redesigned parts racks to reduce dra out W66 Modified or installed rinses stems W67 Improved rinse equipment design W68 Improved rinse equipment operation W71 Other cleaning and degreasing operation (explain briefly in continents) W72 Modified spray systems orequipment W73 Substituted coating materials used W74 Improved application techniques W75 Changed from spray to others stein W78 Other surface preparation and finishing (explain briefly in comments) W81 Changed product specifications W82 Modified design or composition of product W83 Modified packaging W89 Other product modifications (explain briefly in comments) W99 Other (specify in comments ) Comments (Please list corresponding code) Title: M Wastewater Survey & Pemut Application Filename: https://tryonfmishmg-my.sharepointcom!persondnaiden tryonfmshmg_com/Documents/Licenses and Permits/Town of Tryon/Industrial Wastewater Survey & IUP Permit Application (Long Form) - 06.06.23.docx Revision date: 12/30/97 Page 20 of 208 20 of 21 6/12/2023, 9:24 AM x�n.a�Naxla u.w Hxl osiexw,arr�. s.hal= wYrtlxwCR oa. u.. .Rbx. rw .. a..w.yin > hww.tlR Mra mau. x®uvra Mnwpx ..wa. RNllwu. go+ea+ rurnm ilsa'x'xx.. xp. A'N +nwwrwe4x..we M.siunme bxt •..x.a xa./mm,wa O� f.Nwi.q Ir�/a.e/ w w.Yrlq ..pksyw.m nw P�Mh: fQ�t new y.q •x.s.4.a0a.Nsbn nov �.a1M u..r gWxa.laA Nu. wu.In %.i.rm c iam..,,w.. ov e� P.1.1 I W 5 submi[.I -- 1