HomeMy WebLinkAboutNCG020775_CEI Report_20230530Compliance Inspection Report
Permit: NCG020775 Effective: 07/01/21 Expiration: 06/30/25 Owner: 401 Sand Company LLC
SOC: Effective: Expiration: Facility: A & H Mine
County: Hoke DOC Brown Rd
Region: Fayetteville
Raeford NC 28376
Contact Person: John A Lindsay Title: Phone: 910-875-2108
Directions to Facility:
--200 ft east of Handon-Leak Rd. (east of municipal airport)
System Classifications: SWNC,
Primary ORC: Certification:
Secondary ORC(s):
On -Site Representative(s):
On -site representative
Related Permits:
Inspection Date: 05/30/2023
Primary Inspector: Bailey L Taylor
Secondary Inspector(s):
John A Lindsay
Phone:
910-875-2108
Entry Time 10:10AM Exit Time: 01:30PM
Phone: 910-433-3300
Penny Markle
Reason for Inspection: Routine Inspection Type: Compliance Evaluation
Permit Inspection Type: Mining Activities Stormwater Discharge COC
Facility Status: ❑ Compliant Not Compliant
Question Areas:
Storm Water
(See attachment summary)
Page 1 of 3
Permit: NCG020775 Owner-Facility:401 Sand Company LLC
Inspection Date: 05/30/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
During the compliance inspection, inspectors met with Josh Byrd and Mr.Lindsay. The inspection began at 10:10 am and
concluded at 1:30pm. During the inspection, inspectors reviewed the Stormwater Pollution Prevention Plan and found it had
not been updated. The SWPPP was missing critical documentation such as; the recording of spills (or the lack of spills) for
the previous three years, an updated site map including all of the stormwater outfalls, weekly site inspection reports, the
annual evualuation of non-stormwater discharges at outfalls, annual training records/documentation and updated site
personell contacts. In addition, the facility had not been conducting the quarterly analytical and qualitative monitoring per the
permit requirement. Due to these reasons a Notice of Violation will be issued. All outfalls were observed during the site visit.
Minor sediment accumulation was observed at the inlet and outfall of outfall D. Currently, the site does not produce any
waste water discharges or conduct any vehicle maintenance and they did not have any liquid storage onsite. This facility had
not registered for eDMR at the time of the inspection.
Page 2 of 3
Permit: NCG020775 Owner-Facility:401 Sand Company LLC
Inspection Date: 05/30/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Stormwater Pollution Prevention Plan
Yes No NA NE
Does the site have a Stormwater Pollution Prevention Plan?
❑ ❑ ❑
# Does the Plan include a General Location (USGS) map?
❑ ❑ ❑
# Does the Plan include a "Narrative Description of Practices"?
❑ ❑ ❑
# Does the Plan include a detailed site map including outfall locations and drainage areas?
❑
❑ ❑
# Does the Plan include a list of significant spills occurring during the past 3 years?
❑
❑ ❑
# Has the facility evaluated feasible alternatives to current practices?
❑ ❑ ❑
# Does the facility provide all necessary secondary containment?
❑
❑ ❑
# Does the Plan include a BMP summary?
❑ ❑ ❑
# Does the Plan include a Spill Prevention and Response Plan (SPRP)?
❑ ❑ ❑
# Does the Plan include a Preventative Maintenance and Good Housekeeping Plan?
❑ ❑ ❑
# Does the facility provide and document Employee Training?
❑
0 ❑ ❑
# Does the Plan include a list of Responsible Party(s)?
0
❑ ❑ ❑
# Is the Plan reviewed and updated annually?
❑
0 ❑ ❑
# Does the Plan include a Stormwater Facility Inspection Program?
0
❑ ❑ ❑
Has the Stormwater Pollution Prevention Plan been implemented?
❑
0 ❑ ❑
Comment: The facility has missing documentation in the SWPPP. Since the addition to the mine,
another
outfall was added and the site map has not been updated. The site has not been recording
significant spills, or the lack thereof. The site has not been conducting and/or documenting
annual employee trainings. The SWPPP has not been updated annually. Due to these
reasons, the SWPPP has not been implemented.
Qualitative Monitoring
Has the facility conducted its Qualitative Monitoring? ❑ 0 ❑ ❑
Comment: Qualitative monitoring has not been conducted in accordance with the quarterly permit
requirements.
Analytical Monitoring Yes No NA NE
Has the facility conducted its Analytical monitoring? ❑ 0 ❑ ❑
# Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ 0 ❑
Comment: Analytical monitoring has not been conducted in accordance with the quarterly permit
requirements.
Permit and Outfalls Yes No NA NE
# Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑
# Were all outfalls observed during the inspection? ❑ ❑ ❑
# If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ❑
# Has the facility evaluated all illicit (non stormwater) discharges? ❑ 0 ❑ ❑
Comment:
Page 3 of 3