Loading...
HomeMy WebLinkAbout770018_NOV-2023-PC-0128 Response from Owner_20230401RECEIVED JUN 0 a 2023 1--3,v29q June 5, 2023 ®EQ•FAYETTEVILLEREMNALOFFICE J. 'Trent Allen NC Dept. of Environmental Quality Division of Water Resources Fayetteville Regional Office 225 Green St, Suite 714 Fayetteville, NC 28301-5043 Subject: Response to Notice of Violation NOV 2023-PC-0128 Chris Yaklin Farm Facility Number 77-18 Permit AWS0770018 Richmond County, Dear Trent Allen, As operator in charge, I missed the fact that the reel calibration was out of date, and I should have been more consistent with my lagoon samples, which led to the over application. The following steps have beer' or will be taken to prevent future violations: 1. We have hired a full-time person to do office work. She has a calendar with important dates marked for lagoon sample dates. We plan to have samples prior to pumping, and do the math first before pumping. We have other fields in our plan we can use. Enclosed is our current sample. 2. We are currently clearing another 30 acres which will be added to our waste plan. 3. Calibration is not hard. We have worked with our local extension, and enclosed is our current calibration. 4. We will be working with Extension further, to see if we can adjust our waste management plan to fully utilize our land. We are currently looking at different crops for our plan and potentially a different application method. Sincerely, Z d - Chris Yaklin attachment NCDA&CS Agronomic Division Phone: (919) 664-1600 Website: www.ncagr.gov/agronomi/ Report No. FY23-WO05734 Predictive Client: Christopher Yadkin 929 W NC Hwy 73 Advisor: Ellerbe, NC 28338 Waste Report Richmond County kinks to Helpful Information Sampled: 04/25/2023 Received: 04127/2023 Farm: Not Provided Completed: 04/28/2023 PALS #: 540377 PALS #: Sample Information Nutrient Measurements are given in units of milligrams per liter (mg/L), unless otherwise specified. Other Results ID: 042523 Nitrogen (N) (mg/L) P K Ca Mg S Fe Mn Zn Cu B Me ( C At Na Cl Code: ALS Total N: I 39.4 1090 127 24.2 32.7 3.53 0.65 1.61 0.61 1.02 - - 1.03 342 - Description: Swine Total Kjeldahl N: 650 LagoonLiy. Inorganic: ----------------------------------- Grower Comments: NH4-N SS EC pH BD CCE ALE QN DM Not Provided NO3-N I (10 S/cm) (mS/cm) (Unitless) (lb/yd3) N (1000 gal) (Unitless) N - - 7.83 - - - - - Estimate of Nutrients Available for First Year (lb/1000 gal) Other Results (Ib/1000 gal) Application Method: N P205 K20 Ca Mg S Fe Mn Zn Cu B Mo AI Na Cl Irrigation 2.71 0.75 10.9 1.06 0.20 0.27 0.03 0.01 0.01 0.01 0.01 - 0.01 2.85 - North Carolina A,,��t M1 ; Tc bxco Ttum Nnd Co mrr iwm Reprogramming of the laboratory -information -management system that makes this report possible is being funded through a grant from the North Carolina Tobacco Trust Fund Commission. Thank j ou for using agronoruic sen ices to manage indrients and safeguard erns nnieutal qualiti . - Steve Troxlet. Canniissianer ofAgricitltta-e. J['I iILLt�tYl ]l t A%-.Wl it JL`J*,O %JtY 1viilf i.l v FLOW METER VV oFIELD CALIBRATION TION: Yaklin Farm 77-0018 PHONE: 910 334-2255 TE OF FIELD CALIBRATION: 05/12/23 FLOW METER SERIAL NUMBER: NA REEL/GUN/SPRINKLER MAKE AND MODEL: Nelson 150 (see reverse for solid set system) EASURED RING SIZE (from irrigation design): 1.00 inches ring within .01 % of expected manufacturer size? not, ring must be replaced PRESSURE READINGS AT PUMP: AT REEL: AT GUN: )W RATE (GPM) n manufacturers chart flow meter readout) psi (optional) psi (optional) 70 psi (required) EXPECTED: 138 ` gam MEASURED: NA gym VARIANCE: % WETTED DIAMETER (ft) EXPECTED: 340 It (see wettable acres determination MEASURED: GLIl ft for expected diameter) VARIANCE: Ll�/o wetted -diameter is greater than 15% or flow rate variance is greater than 10%, ntact a Certified Technical Specialist or irrigation specialist for assistance. id/or Explain findings: C,1;zd7 °: TOR: A. Growe (print name) (signature)' Phone: 910-206 2772 N C s�� unnrersdy asTs� '9,V Ntr COOPERATM EXTENSION AIIIIIIIIII fromiedm -fto, -vSates average of the pressures and put in the blank on the front of this sheet. Also take the average of the wetted diameters and put in the blank on the front of this sheet. Sprinkler Gun Pressure Wetted Diameter Sprinkler 1 Sprinkler 2 7 Sprinkler 3 Sprinkler 4 Average Measuring Wetted Diameter: To measure wetted diameter, measure the distance from the gun to the end of the throw of water. This will give you the radius. Multiply this number by 2 to get diameter. Additional Notes: