Loading...
HomeMy WebLinkAboutNCC231864_Site Plan or Location Map_20230615 DEVELOPMENT PLAN: 22-REZ-08/PLRZ202200213 DRAWING NUMBER CFD-XXXXXX A000 -XXXXXX $ DUKE ENERGY® MAILING ADDRESS: P.O.BOX 1007 DUKE ENERGY PROGRESS HOLLY SPRINGS CHARLOTTE,NC Safety Expectations: hiLLNESSII Reduce Risk OPERATIONS CENTER AND TRAINING FACILITY ZIIIW E R UI Remove Exposures to Hazards Reinforce Safe Behavior 1 i WOODS CREEK ROAD (S.R. 1154) AND WOODFIELD DEAD END ROAD (S.R. 1155) HOLLY SPRINGS, NORTH CAROLINA 27539 s H H LAT: 35.677736 LONG: -78.881189 SHEET INDEX g PROJECT INFORMATION C0.00 COVER SHEET ; ARCHITECTURE C1.00 EXISTING CONDITIONS 1100 Dresser Court DUKE PROGRESS, LLC(DEP) C1.01 CLEARING AND DEMOLITION PLAN .g 411 FAYETTEVIE STREET Raleigh,NC 27609 LANDOWNER 0 Office 919.828.2301 RALEIGH,NORTH CAROLINA 27601 C2.00 OVERALL SITE PLAN PHONE:(919)-546-7169 A Email offce@hh-arch.com HH ARCHITECTURE EARLY SITE PHASE ROUGH GRADING C2•o1 SITE PLAN 'A' ARCHITECT 1100 DRESSER COURT RALEIGH,NORTH CAROLINA 27609 C2.02 SITE PLAN 'B' PHONE:(919)-828-2301 C2.03 SITE PLAN 'C' E MCADAMS PROJECT NUMBER: DKE22004 4 " ENGINEER 2905MERIDIANPARKWAY C3.00 OVERALL GRADING AND STORM DRAINAGE PLAN DURHAM,NORTH CAROLINA 27713 C3.01 GRADING AND STORM DRAINAGE PLAN 'A' PHONE:(919)-361-5000 e MCADAMS C3.02 GRADING AND STORM DRAINAGE PLAN 'B' SURVEYOR 2905 MERIDIAN PARKWAY DATE: MAY 16t h, 2023 DURHAM,NORTH CAROLINA 27713 C4.00 OVERALL UTILITY PLAN T PHONE:(919)-361-5000 C4.01 UTILITY PLAN 'A' L} EXISTING USE VACANT C4.02 UTILITY PLAN 'B' S MCADAMS INFRASTRUCTURE UTILITIES(MAJOR) C4.03 UTILITY PLAN 'C' THE TOWN OF HOLLY SPRINGS HAS INSTALLED A LOCAL GEODETIC MONUMENTATION GRID, PROPOSED USE OFFICE USE/BUSINESS SERVICES TIED TO NAD83,WITHIN AND SURROUNDING THE TOWN LIMITS.ALL SURVEYED INFORMATION(WHEN ANY PORTION OF THE PROJECT IN DESIGN IS WITHIN 2000 FEET OF a The John R.McAdams Company,Inc. TELECOMMUNICATION TOWER OWNER R E P R E S E N T I T I V E. C4.04 UTILITY PLAN 'D' THE TOWN'S GEODETIC MONUMENT)SHALL REFERENCE THE NEAREST MONUMENT AND SHALL BE CLEARLY NOTED ON THE FIRST SHEET OF,BOTH CONSTRUCTION PLANS,AND 621 Hillsborough Street EXISTING BUILDING N/A C6.00 OVERALL EROSION CONTROL-PHASE 1 AS-BUILTS SUBMITTED TO THE TOWN. Suite SOO PARCEL ID 0629626959 CONTACT: MARK B. FRANKLIN C6.01 EROSION CONTROL PLAN'A'-PHASE 1 Raleigh,NC 27603 C6.02 EROSION CONTROL PLAN'B' PHASE 1 phoneax 919.361.1269 MAP BOOK AND PAGE NUMBER SEE PLANS 410 S. WILMINGTON STREET RALEIGH NC. 27602 C6.03 EROSION CONTROL PLAN'C'-PHASE 1 ALL CONSTRUCTION SHALL CONFORM TO TOWN fax er:C-0293,2 DEED BOOK AND PAGE NUMBER SEE PLANS C6.04 EROSION CONTROL PLAN'D'-PHASE 1 OF HOLLY SPRINGS ENGINEERING DESIGN AND license number: C-187 EMAIL: MAR K B.FRANKLIN.J L L-A M.C O M C6.05 OVERALL EROSION CONTROL-PHASE 2 CONSTRUCTION STANDARDS www.mcadamsco.com SITE ZONING H.I.CD-HEAVY INDUSTRIAL CONDITIONAL ZONING DISTRICT C6.06 EROSION CONTROL PLAN'A'-PHASE 2 TOTAL ACREAGE AREA TOTAL PARCEL=95.59 AC.or 4,163,864 SF. PHONE: (919)-828-2301 C6.07 EROSION CONTROL PLAN'B'-PHASE 2 CONSTRUCTION DRAWING APPROVAL IS LOT 1=84.61 AC.or 3,685,699 SF. C6.08 EROSION CONTROL PLAN'C'-PHASE 2 REQUIRED BEFORE CONSTRUCTION ON THIS LOT 2=4.11 AC.or 179,175 SF. LOT 3=4.41 AC.or,91,81s,,a,SSF. C6.09 EROSION CONTROL PLAN'D'-PHASE 2 PROPERTY MAY BEGIN.DEVELOPMENT FEES ARE WOODFIELD DEAD END ROAD=2.46 AC.or 107,175 SF. C6.10 OVERALL EROSION CONTROL-PHASE 3 DUE BEFORE CONSTRUCTION DRAWING APPROVAL. TREE CONSERVATION AREA 9.39 AC.(10.18%) C6.11 EROSION CONTROL PLAN'A'-PHASE 3 r`so',A cm() ACREAGE OF LAND TO BE 56.22 AC.=PROPOSED DEVELOPMENT ONLY .� V t C6.12 EROSION CONTROL PLAN'B'-PHASE 3 matr +,,I°'- .•y_ DISTURBED/EXPOSED (DOES NOT INCLUDE FUTURE DEVELOPMENT OF LOTS 2 AND 3) V TOWN OF HOLLY SPRINGS .-' azHL"" i m ti C6.13 EROSION CONTROL PLAN'C'-PHASE3 I CERTIFY THAT THESEP PLANS WERE PREPARED AND THAT THIS PROJECT SHALL BE 55 CY MONUMENT CONTROL POINT CONSTRUCTED THAT PLANNCEWITHTHE FOLLOWING PLANS, 034365 EXISTING IMPERVIOUS AREA 1.24 AC.or 54,084 SF. 'D' J _ fo "STEVEN"ONE MILE NORTH OF C6.14 EROSION CONTROL PLANPHASE 3 °= A �... Ce-1 • OF THE ENGINEERING DESIGN AND CONSTRUCTION STANDARDS OF THE TOWN OF PROPOSED IMPERVIOUS AREA LOT 1=22.65 AC.or 986819 SF.(26.8%) 0 • INTERSECTION C7.00 PLAN AND PROFILE-SANITARY SEWER MAIN 'A' HOLLY SPRINGS AND OTHER APPLICABLE TOWN ORDINANCES AND POLICIES.THE ,�''9T OJ�O� • ENGINEER WHOSE SEAL AND SIGNATURE APPEAR BELOW CERTIFIES THAT THE �''o R/CIC L,G LOT2(FUTURE)=2.51 AC.or 109,336 SF.(2.97%)(STORM STAGING AREA) y FIRE STATION • C7,01 PLAN AND PROFILE-SANITARY SEWER MAIN 'B' TOWN OF HOLLY SPRINGS ENGINEERING DESIGN AND CONSTRUCTION STANDARDS LOT 2=TBD •- HAVE BEEN THOROUGHLY REVIEWED FOR APPLICABILITY TO THIS PARTICULAR grrn. LOT 3=TBD t FUTURE • C7.02 PLAN AND PROFILE-WATER MAIN PROJECT.ANY PROPOSED EXCEPTIONS OR DEVIATIONS FROM THE STANDARDS ARE FINAL DRAWING WOODFIELD DEAD END ROAD=1.36 AC.or 59,063 SF.(55.3%) LISTED SPECIFICALLY ON THE CERTIFICATION OF PLAN SUBMITTAL FORM. TOTAL=26.52 AC.or 1,155,218 SF.(27.7%) C8.00 SITE DETAILS FURTHERMORE,THESE PLANS WERE PREPARED IN CONFORMANCE WITH THE RELEASED FOR CONSTRUCTION PROPOSED APPROVED PRELIMINARY PLAN FOR THIS PROJECT. ACTIVE RECREATION SPACE 2.51 AC. WOODFIELD C8.01 SITE DETAILS DEAD END ROAD C8.02 SITE DETAILS RIVER BASIN CAPE FEAR RIVER BASIN ,•'• EXISTING C8.03 WATER DETAILS EXISTING VEHICLE PARKING NONE i DATE ISSUED:5-16-2023 DEADDEND ROAD C8.04 WATER DETAILS OPERATIONS CENTER 23,748 SOFT.(OFFICE)W/18,175 SOFT.(INFRASTRUCTURE) ''-� C8.05 RECLAIM WATER DETAILS HOLLY SPRINGS MIN.48 PARKING SPACES(1 VAN ADA,5 ADA.7 EV,AND 21 EV READY) OPERATIONS CENTER 'Po, C8.06 STORM DRAINAGE DETAILS OPERATIONS REQUIRED VEHICLE PARKING MAX.94 PARKING SPACES(1 VAN ADA,5 ADA,7 EV,AND 21 EV READY) C8.07 STORM DRAINAGE DETAILS CENTER NOTE:INFRASTRUCTURE USES HAVE NEITHER MINIMUM OR MAXIMUM C8.08 STORM DRAINAGE DETAILS PARKING REQUIREMENTS CINDER STATION ROAD 146 TOTAL PARKING SPACES C8.09 SANITARY SEWER DETAILS PROPOSED VEHICLE PARKING CLIMBING BARN C8.10 SANITARY SEWER DETAILS - (111 PARKING SPACES,1 VAN ADA,5 ADA,8 EV,AND 21 EV READY) o BUILDING HEIGHTS 27 FT. TRAINING CENTER C8.11 SIGNAGE AND FENCE DETAILS PROJECT STATUS: DEVELOPMENT C8.12 EROSION CONTROL DETAILS OUTDOOR STORAGE TOTAL=14.13 ACRES or 615,502.8 SF.(15.39%) C8.13 EROSION CONTROL DETAILS TRAINING CENTER 18,329 SOFT.(OFFICE)W/6,510 SOFT.(INFRASTRUCTURE) C8.14 EROSION CONTROL DETAILS REQUIRED VEHICLE PARKING MIN.36 PARKING SPACES(1 VAN ADA,5 ADA.7 EV,AND 21 EV READY) C8.15 EROSION&SEDIMENT CONTROL NOTES MAX.73 PARKING SPACES(1 VAN ADA,5 ADA.7 EV,AND 21 EV READY) ` C8.16 EROSION&SEDIMENT CONTROL NOTES NOTE INFRASTRUCTURE USES HAVE NEITHER MINIMUM OR MAXIMUM �l gr'��I L C8•17 EROSION&SEDIMENT CONTROL NOTES L PARKING REQUIREMENTS ... .f l PROPOSED VEHICLE PARKING 146 TOTAL PARKING SPACES O C9.00 STORMWATER CONTROL MEASURE PLAN VIEW (111 PARKING SPACES,1 VAN ADA,5 ADA,8 EV,AND 21 EV READY) t1 C9.01 STORMWATER CONTROL MEASURE DETAILS BUILDING HEIGHTS 27 FT. \ C9.02 STORMWATER CONTROL MEASURE DETAILS C9.03 STORMWATER CONTROL MEASURE DETAILS CLIMBING BARN 2,961 SOFT.(INFRASTRUCTURE) 64¢ L1.00 OVERALL LANDSCAPE PLAN m REQUIRED VEHICLE PARKING NONE L1.01 LANDSCAPE PLAN'A' z PROPOSED VEHICLE PARKING NONE L1.02 LANDSCAPE PLAN'B' BUILDING HEIGHTS 47.2 FT. VICINITY MAP L1.03 LANDSCAPE DETAILS o TRAINING POLES MONOPOLE SCALE: 1" = 500' E1.00 LIGHTING PLAN A200 ZONING ELEVATIONS ie E STRUCTURE HEIGHT SO Fr. A201 ZONING ELEVATIONS-TRAINING MIGRATORY BIRD HOTLINE PROJECT NO. 22-008 A202 ZONING ELEVATIONS-ACCESSORY STATE AND FEDERAL LAWS PROTECT ALL SPECIES OF NATIVE BIRDS FOUND THROUGHOUT THE DUKE ENERGY SERVICE COMMUNICATIONS TOWER MONOPOLE AREA.INTERACTIONS OF BIRDS WITH GENERATING FACILITIES,TRANSMISSION AND DISTRIBUTIONS,SUBSTATIONS DRAWING NUMBER R2.00 ROADWAY SHEET OTHER STRUCTURES AND EQUIPMENT,AND OPERATIONS ARE POTENTIALLY HARMFUL OR FATAL TO BIRDS.DUKE CFD-XXXX- A000 XXXXX STRUCTURE HEIGHT 34 FT. ENERGY OPERATES THESE 24-HOUR MIGRATORY BIRD HOTLINES TO ASSIST EMPLOYEES AND CONTRACTORS WITH R2.01 ROADWAY SHEET RELATED INCIDENTS THAT OCCUR DURING WORK ACTIVITIES. R2.02 ROADWAY SHEET ELECTRONIC FILE NABtFD01-NCDEQ.DWG BICYCLE PARKING NONE CAROLINAS:800.573.3853 I FLORIDA:727.386.3084 I MIDWEST:317.430.4497 DRAWN BY:SMP BUILDING SETBACKS 30 FT.FRONT,30 FT.(ALONG WOODSCREEK ROAD),5 FT.SIDES,5 FT.REAR El I 1 0 "(811)OR(1-800-632 4949) AT SPILL REPORTING HOTLINE CHK'D BY:KAS NUMBER OF SCM'S<5 AC. 0 ��� CONTRACTOR SHALL NOTIFY"NC811 LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION E-MAIL:COVIL@MCADAMSCO.COM IN ORDER TO ENSURE THE PROTECTION OF HUMAN HEALTH AND THE ENVIRONMENT,FEDERAL AND STATE LAWS NUMBER OF SCM'S>5AC. 1 OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. REQUIRE THAT CERTAIN TYPES OF SPILLS AND UNPERMITTED RELEASES BE REPORTED TO THE PROPER REGULATORY Tnso202N ORoe,o IS THE EXCLUSIVE rEUSHVUr DONE ENERGY CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE AGENCIES AS SOON AS POSSIBLE FOLLOWING IDENTIFICATION.IMMEDIATELY NOTIFY YOUR SUPERVISOR AND THE CWORK.AND iSCGSIorRRoOrrmiHm:.YsxnI NOT BE TOTAL STORM DRAINAGE PIPE LENGTH TBD Know what's below. THEIR OWN LOCATOR SERVICES INDEPENDENT OF"NC811". 45 FIELD ENVIRONMENTAL/EHS PROFESSIONAL WHEN ASPILLOR UNPERMITTED RELEASE IS DISCOVERED.IFYOU ARE NPASBRON SHOULD ONLY aE USED FOR PRESPECIFlCaNO.ECMOPED,COMM 012 DISTRIBUTED WITHOUT PROP APPROVAL iiNrrxr. il- UNABLE TO REACH THE FIELD ENVIRONMENTAL/EHS PROFESSIONAL,CONTACT ONE OF THE DUKE ENERGY SPILL Call before you dig. REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. REPORTING HOTLINES AT: SHEET TITLE CAROLINAS&MIDWEST:800.527.3853 I FLORIDA:866.769.1266 COVER SHEET SHEET NO.