Loading...
HomeMy WebLinkAbout20230549 Ver 1_revised impact map_20230524STREAM 6 MIL. PLASTIC PUMP EXCESS WATER TO APPROVED DEWATERING DRY WORK AREA SAND OR GRAVEL BAG COFFERDAM NOT TO SCALE TEMPORARY CREEK CROSSING PUMP AROUND DETAIL (NTS) PLAN VIEW SECTION A -A !. DESCRIPTION THE WORK SHALL CONSIST OF INSTALLING A PUMP AROUND WHEN CONSTRUCTION ACTIVITIES TAKE PLACE WITHIN THE STREAM CHANNEL II. MATERIAL SPECIFICATIONS SANDBAGS: SANDBAGS SHALL CONSIST OF MATERIALS WHICH ARE RESISTANT TO ULTRAVIOLET RADIATION, TEARING AND PUNCTURE, AND WOVEN TIGHTLY ENOUGH TO PREVENT LEAKAGE OF FILL MATERIAL (i.e. SAND, FINE GRAVEL, ETC.) III. CONSTRUCTION REQUIREMENTS 1. ALL EROSION AND SEDIMENT CONTROL DEVICES SHALL BE INSTALLED AS THE FIRST ORDER OF WORK. 2. THE HEIGHT OF THE SANDBAGS SHALL BE AS INDICATED IN SECTION A -A. THE SANDBAGS SHALL BE PLACED ON A SMOOTH PREPARED SURFACE. 3. ALL EXCAVATED MATERIALS SHALL BE DISPOSED OF OUTSIDE THE 100 YEAR FLOOD PLAIN UNLESS APPROVED ON THE PLANS. 4. ALL DEWATERING OF THE CONSTRUCTION AREA SHALL BE PUMPED TO A DEWATERING PUMP DISCHARGE FILTER BAG OR SILT BASIN. 5. THE PUMP SHALL BE OF SUFFICIENT SIZE TO CONVEY NORMAL STREAM FLOW. 6. SEDIMENT CONTROL DEVICES ARE TO REMAIN IN PLACE UNTIL ALL DISTURBED AREAS ARE STABILIZED AND THE CITY ENGINEERING DEPT APPROVES THEIR REMOVAL. W1 FT. �8" O.C.(TYP.) REFER TO CHART FOR BAR SIZE ELEVATION PLAN SIDE z oN H r I- NOTES: Q H • THIS PRECAST ENDWALL MAY BE USED FOR THE FOLLOWING ,zycr U STANDARDS: 838.01, 838.11, 838.21, 838.27, 838.33, LL J d ++ 2 838.39, 838.51, 838,57, 838.63 AND 838.69. O S O') _ • INSTALL PRECAST ENDWALLS WITH WINGS AND PAY W Q Q W = FOR IN ACCORDANCE WITH SPECIFICATION SECTION 838. ~Q U OCD • USE 4000 PSI CONCRETE. F 3_ ~ z W ` PROVIDE ALL REINFORCING STEEL WHICH MEETS ASTM A615 W I- LL O J FOR GRADE 60 AND WELDED WIRE FABRIC CONFORMING p U w Q Q TO ASTM A185 WITH 2" MIN. CLEARANCE. z i • PLACE LIFT HOLES OR PINS IN ACCORDANCE WITH H ice+ OL OSHA STANDARD 1926.704. W o • PIPE TO BE GROUTED INTO HEADWALL AT JOB SITE BY o CONTRACTOR • ALL ELEMENTS PRECAST TO MEET ASTM C913. • WELDED WIRE FABRIC MAY BE SUBSTITUTED FOR REBAR AS LONG AS THE SAME AREA OF STEEL IS PROVIDED. • CHAMFER ALL CORNERS 1" OR HAVE A RADIUS OF 1". 3 NOTE: THE MINIMUM BAR SIZE SHALL BE #5 BARS J Y AT 8" CTS.THE CONTRACTOR WILL HAVE THE OPTION ¢ O _j TO INCREASE THIS BAR SIZE AS NEEDED, u- m G H Z ENDWALL DIMENSIONS FT. MINIMUM MIN./MAX. MIN./MAX. MIN./MAX. MIN./MAX. MIN./MAX. PIPE DIA. BAR SIZE H7(FT.) H2(FT.) D (FT.) W1 W2 1.0 #5 @ 8" 1.25/2.00 2.00/3.75 1.2511.75 3.00/3.75 5.50/6.00 1.25 #5 @ 8" 1.25/2.00 3.00/3.75 1.25/2.00 3.50/3.75 6.50/6.75 1.50 #5 @ B" 1.25/2.00 3.00/4.25 1.5012.50 3.50/3.75 6.50/6.75 2.0 #5 @ 8" 1.50/2.50 4.00/4.75 1.75/2.50 4.00/4.25 7.50/8.25 2.5 #5 @ 8" 2.50/3.50 4.00/6.00 2.00/3.00 4.50/5.50 10.00/11.50 3.0 #5 @ 8" 3.00/3.50 5.00/6.00 2.75/3.50 5.2515.75 11.50111.75 3.5 #5 @ 8" 3.2514.50 6.00/6.75 3.25/3.50 6.00/6.75 12.00/13.25 4.0 #5 @ 8" 3.50/4,50 6.50/7.00 3.25/3.50 6.50/6.75 13.00/13.25 4.5 #5 @ 8" 4.00/5.00 6.50/8.50 3.25/4.00 7.00/9.25 13.50/15.75 6.0 #5 @ 8" 4.50/5.00 7.00/8.50 3.25/4.00 7.25/9.25 13.75/16.75 5.5 #5 @ 8" 4.50/5.00 7.50/8.50 3.25/4.00 7.25/9.25 14.00/15.75 6.0 #5 @ 8" 4.50/5.00 7.50/8.50 3.25/4.00 7.75/9.25 14.75/16.75 UJ w o W o FUJ C] N CC n z 2 = O N oa z o Lu 4tl IL O LL 1' A -woo- PERMANENT BUFFER DISTURBANCE PZ 2B= 2,262 SF JE-r \ >`� ~' - �� "°•� �� PERMANENT BUFFER DISTURBANCE 30'x15'x2' CLASS 1 PZ 1 B= 3,984 SF RIP RAP PAD \ \ PERMANET STREAM '/ DISTURBANCE �. _. S2_ 141 SF (30 LF) ////H//p / / TE BYPASSPIPIPE � EADWALL 001 NCDOT STD. 838.80 PERMANENT BUFFER STURBANCE DISTURBANCE / PZ 1o=4,122 SF / PERMANENT BUFFER DISTURBANCE / PZ 2A=1,976 SF N., / 'A -1+00 780 775 770 765 760 PROPOSED 0+00 / TEMPORARY SANDBAGS HEADWALL 002 NCDOT STD. .8 .80 INV' 750.40' 60" RCP @ 4.16% / 000, / /� o .000 / 004, CENTERLINE OF STREAM -TS 2: 55 SF (10 LF) 5' APPROXIMATE PUMPAROUND STREAM TOB \7 TEMP. IMPACTS = ZONE 30'STREAM BUFFER ZONE2 fl, I -20'STREAM BUFFER i WETLANDS TEMPORARY CREEK (TYP.) / CROSSING PUMP l000l(SEE DETAILS) PERMANENT / WETLAND DISTURBANCE W1 = 357 SF PERMANENT STREAM _ IMPACT St = 680 SF (136 LF) ---- 30 0 15 30 60 120 SCALE: 1" = 30' 1+00 2+00 HW 002 STA. 1+05.82 RIM 758.90 IN 750.40 I EXISTING GRADE OF� m / CROSSING CULVERT I i / cP @y. 106� RIP RAP APRON EXISTING GRADE 0.I MUST 745 J60 \L ITY p `"Vp CENTERLINE T REIN OpJ� O O ,.1 � _... � � CENTERLINE ... J 0 Q Z D m 0 i I BEFORE YOU DIG! _ CONTACT ONE -CALL CENTER 755 750 740 HW 001 `STA. 0+00.00 RIM 753.50 IN 745.00 VICINITY MAP 1"=2000' SITE DATA PARCEL: 84035 PIN:7887697696 OWNER: GREENS APARTMENT LLC PROPERTY ADDRESS: 4717 4733 US HIGHWAY 29 N DB: 8643 PG: 2677 TOTAL SITE AREA: 23.82 ACRES RIGHT OF WAY DEDICATION: 2A7 ACRES EFFECTIVE SITE AREA: 21.35 ACRES ZONING: EXISTING ZONING: CD RM-18 LAND USE: MULTI-FAMILY/DUPLEX CROSSING EXHIBIT NOTES: 1. EXISTING GRADES ARE PROVIDED BY TOPOGRAPHIC SURVEY BY FEI AND NCDOT LIDAR. EXISTING SITE CONDITIONS ARE TO BE VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION. 2. UTILITY INSTALLATION AND IMPACTS SHALL FOLLOW ALL APPROVED PERMITS. 3. TEMPORARY STREAM CROSSING MATERIAL TO BE REMOVED FOLLOWING THE COMPLETION OF THE CULVERT CROSSING INSTALLATION. 4. CONTRACTOR TO VERIFY ELEVATIONS IN STREAM BED PRIOR TO INSTALLATION. ANY DISCREPANCIES BETWEEN PLAN AND FIELD CONDITIONS SHOULD BE NOTIFIED TO THE ENGINEER IMMEDIATELY. TEMPORARY IMPACT SUMMARY: TEMPORARY STREAM IMPACT TS 2: 10 LF/ 55 SF PERMANENT IMPACT SUMMARY: ZONE 1: PERMANENT BUFFER IMPACT PZ 1A: 4,128 SF (0.095 AC) PZ 1 B: 3,984 SF (0.091 AC) ZONE 1 TOTAL: 8,112 SF (0.186 AC) ZONE 2: PERMANENT BUFFER IMPACT: PZ 2A: 1,976 SF (0.045 AC) PZ 26: 2,262 SF (0.052 AC) ZONE 2 TOTAL: 4,238 SF (0.097 AC) PERMANENT STREAM IMPACT: S1: 136 LF/ 680 SF (0.016 AC) S2: 30 LF/141 SF (0.013 AC) TOTAL: 821 SF (0.019 AC) PERMANENT WETLAND IMPACT: W1: 357 SF (0.008 AC) STORMWATER MANAGEMENT INFORMATION 1. THIS PROPERTY IS LOCATED WITHIN FLOOD ZONE X (ZONE X AREAS ARE DETERMINED TO BE OUTSIDE THE 0.2%ANNUAL CHANCE FLOODPLAIN) AREA AS INDICATED ON THE FLOOD INSURANCE RATE MAP (FIRM) MAP NUMBER 3710788700J, EFFECTIVE DATE JUNE 18TH, 2007. 2. BUILT UPON AREA (BUA) TOTAL AREA: 930,079 SF 21.35 ACRES EXISTING BUA: 103,237 SF 2.37 ACRES (11.10%) EXISTING BUA TO BE REMOVED: 87,556 SF 2.01 ACRES (9.40%) PROPOSED BUILT UPON AREA: 280,091 SF 6.43 ACRES (30.12%) TOTAL BUA: 296,772 SF 6.79 ACRES (31.80%) 3. ALL NECESSARY APPROVALS HAVE BEEN (WILL BE) OBTAINED FROM NCDEQ AND U.S. ARMY CORPS OF ENGINEERS FOR ANY WETLAND DISTURBANCE AND STREAM CROSSING/DISTURBANCE WHERE APPLICABLE. 4. ENGINEER'S CERTIFICATION OF STORMWATER QUANTITY CONTROL: THE NET INCREASE IN BUILT -UPON AREA IS GREATER THAN 400 SQUARE FEET, THEREFORE, THIS DEVELOPMENT IS SUBJECT TO 30-12-7.2(B)(7)(b) OF THE GREENSBORO LAND DEVELOPMENT ORDINANCE. 5. ALL PUBLIC STORM SEWER MUST BE INSTALLED PER NCDOT SPECIFICATIONS. 6. PRIOR TO PUBLIC STORM SEWER INSTALLATION, CONTACT CHAD MANESS AT (336) 373-2336 TO SCHEDULE THE ASSIGNMENT OF AN INSPECTOR. 7. STORM AS-BUILTS REQUIRED FOR ALL NEW PIPES 12" AND LARGER. AFTER TRC APPROVAL, SUBMIT (1) SET OF PLANS TO THE ENGINEERING DEPARTMENT FOR RECORD PURPOSES. PLEASE CALL (336) 373-2052 WITH QUESTIONS. 3 0 1.5 3 6 12 VERTICAL SCALE: 1" = 3' 30 0 15 30 60 120 HORIZONTAL SCALE: 1" = 30' Ln rn T N jn N ` V 1Z >_ O 0 O U 01 C) mLn 'U•- i 7 Ol v 0 0) 0 OvNZ i wHw00 Ln N W 3 _ > Ln �q cu m U CO 3 v J 0 J w O v OZv�N F LIJ ��wZ owF-w cozawm Fco LU m Z w w 00m -0 �w V J = J �X (F'1 v) z Z U) W U) W 0 U r� V z J O Oirww Q CO U_ UU= OZO� J LU00 wOZZ LU y- =) F- �F0h aUUrn