HomeMy WebLinkAbout820107_Routine Inspection_202306130 Division of Water Resources
❑ Division of Soil and Water Conservation
❑ Other Agency
Facility Number: 820107 Facility Status: Active Permit: AWS820107 ❑ Denied Access
Inspection Type: Compliance Inspection Inactive Or Closed Date:
Reason for Visit: Routine County: Sampson Region: Fayetteville
Date of Visit: 06/13/2023 Entry Time: 09:30 am Exit Time: 11:00 am Incident #:
Farm Name: L&L Farms, Inc. Owner Email:
Owner: David M Lockamy Phone: 910-567-2262
Mailing Address: 1045 Hollerin Rd Dunn NC 28334
Physical Address: 1045 Hollerin Rd Dunn NC 28334
Facility Status: 0 Compliant ❑ Not Compliant Integrator: Murphy -Brown LLC
Location of Farm: Latitude: 35' 10' 03" Longitude: 78' 30' 08"
Farm location: Turn left off 421 going north onto Hollering Road (1475). Farm on left approx. 2 miles after turning off 421.
Question Areas:
Dischrge & Stream Impacts Waste Col, Stor, & Treat Waste Application
Records and Documents Other Issues
Certified Operator: Johnny L Tyndall Operator Certification Number: 16752
Secondary OIC(s):
On -Site Representative(s): Name Title Phone
24 hour contact name Johnny Tyndall
On -site representative Johnny Tyndall 910-385-5663
Primary Inspector: Diane Harrison Phone:
Inspector Signature: Date:
Secondary Inspector(s):
Inspection Summary:
24- need calibration last one was 2020
removed sludge last few months
finish filling out IRR forms with weather codes and intials and address
7- work on bare areas and mow to the tow
9- fix pipe going into lagoon
15- weak field of bermuda overseed didn't get removed on time pasture on left need to remove cows for awhile to let grasses
grow
farm has been leased to Johnny Tyndall
Page 1 of 5
Permit: AWS8201M Owner: David M Lockamy Facility Number:820107
Inspection Date:06/13/23 Inspection TypeCompliance Inspection Reason for Visit:Routine
Regulated Operations
Swine
Design Capacity Current promotions
Swine - Feeder to Finish 3,672 I 0
Total Design Capacity: 3,672
Total SSLW: 495,720
Waste Structures
Effective Built Closed Designated Observed
Type Identifier Date Date Date Freeboard Freeboard
Lagoon 1 04/26/2006 I D1/01/1991 19.00 45.00
Page 2 of 5
Permit: AWS82010i Owner: David M Lockamy Facility Number:820107
Inspection Date:06/13/23 Inspection TypeCompliance Inspection Reason for Visit:Routine
Discharges & Stream Impacts
Yes
No NA NE
1. Is any discharge observed from any part of the operation?
❑
MEIEI
Discharge originated at:
Structure
❑
Application Field
❑
Other
❑
a. Was conveyance man-made?
❑
0 ❑
❑
b. Did discharge reach Waters of the State? (if yes, notify DWQ)
❑
0 ❑
❑
c. What is the estimated volume that reached waters of the State (gallons)?
d. Does discharge bypass the waste management system? (if yes, notify DWQ)
❑
0 ❑
❑
2. Is there evidence of a past discharge from any part of the operation?
❑
0 ❑
❑
3. Were there any observable adverse impacts or potential adverse impacts to Waters of the
❑
0 ❑
❑
State other than from a discharge?
Waste Collection, Storage & Treatment
Yes
No NA NE
4. Is storage capacity less than adequate?
❑
0 ❑
❑
If yes, is waste level into structural freeboard?
❑
5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ larc
❑
0 ❑
❑
trees, severe erosion, seepage, etc.)?
6. Are there structures on -site that are not properly addressed and/or managed through a
❑
MEI
❑
waste management or closure plan?
7. Do any of the structures need maintenance or improvement?
0
❑ ❑
❑
8. Do any of the structures lack adequate markers as required by the permit? (Not applicablE
❑
0 ❑
❑
to roofed pits, dry stacks and/or wet stacks)
9. Does any part of the waste management system other than the waste structures require
❑ ❑
❑
maintenance or improvement?
Waste Application
Yes No NA NE
10. Are there any required buffers, setbacks, or compliance alternatives that need
❑ 0 ❑ ❑
maintenance or improvement?
11. Is there evidence of incorrect application?
❑ 0 ❑ ❑
If yes, check the appropriate box below.
Excessive Ponding?
❑
Hydraulic Overload?
❑
Frozen Ground?
❑
Heavy metals (Cu, Zn, etc)?
❑
PAN?
❑
Is PAN > 10%/10 lbs.?
❑
Total Phosphorus?
❑
Failure to incorporate manure/sludge into bare soil?
❑
Outside of acceptable crop window?
❑
Evidence of wind drift?
❑
Application outside of application area?
❑
Page 3 of 5
Permit: AWS82010i Owner: David M Lockamy Facility Number:820107
Inspection Date:06/13/23 Inspection TypeCompliance Inspection Reason for Visit:Routine
Waste Application
Yes No NA NE
Crop Type 1
Coastal Bermuda Grass w/
Rye Overseed
Crop Type 2
Cotton
Crop Type 3
Small Grain Cover
Crop Type 4
Crop Type 5
Crop Type 6
Soil Type 1
Mooshaunee
Soil Type 2
Soil Type 3
Soil Type 4
Soil Type 5
Soil Type 6
14. Do the receiving crops differ from those designated in the Certified Animal Waste
❑
0 ❑
❑
Management Plan(CAWMP)?
15. Does the receiving crop and/or land application site need improvement?
0
❑ ❑
❑
16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre
❑
0 ❑
❑
determination?
17. Does the facility lack adequate acreage for land application?
❑
0 ❑
❑
18. Is there a lack of properly operating waste application equipment?
❑
0 ❑
❑
Records and Documents
Yes
No NA NE
19. Did the facility fail to have Certificate of Coverage and Permit readily available?
❑
0 ❑ ❑
20. Does the facility fail to have all components of the CAWMP readily available?
❑
0 ❑ ❑
If yes, check the appropriate box below.
WUP?
❑
Checklists?
❑
Design?
❑
Maps?
❑
Lease Agreements?
❑
Other?
❑
If Other, please specify
21. Does record keeping need improvement?
❑
0 ❑ ❑
If yes, check the appropriate box below.
Waste Application?
❑
Weekly Freeboard?
❑
Waste Analysis?
❑
Soil analysis?
❑
Waste Transfers?
❑
Weather code?
❑
Rainfall?
❑
Page 4 of 5
Permit: AWS82010i Owner: David M Lockamy Facility Number:820107
Inspection Date:06/13/23 Inspection TypeCompliance Inspection Reason for Visit:Routine
Records and Documents
Yes
No NA NE
Stocking?
❑
Crop yields?
❑
120 Minute inspections?
❑
Monthly and 1" Rainfall Inspections
❑
Sludge Survey
❑
22. Did the facility fail to install and maintain a rain gauge?
❑
❑ ❑
23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipmen
❑
0 ❑ ❑
(NPDES only)?
24. Did the facility fail to calibrate waste application equipment as required by the permit?
0
❑ ❑ ❑
25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the
❑
0 ❑ ❑
appropriate box(es) below:
Failure to complete annual sludge survey
❑
Failure to develop a POA for sludge levels
❑
Non -compliant sludge levels in any lagoon
❑
List structure(s) and date of first survey indicating non-compliance:
26. Did the facility fail to provide documentation of an actively certified operator in charge?
❑
0 ❑ ❑
27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification?
❑
0 ❑ ❑
Other Issues
Yes
No NA NE
28. Did the facility fail to properly dispose of dead animals within 24 hours and/or document
❑
0 ❑ ❑
and report mortality rates that exceed normal rates?
29. At the time of the inspection did the facility pose an odor or air quality concern? If yes,
❑
0 ❑ ❑
contact a regional Air Quality representative immediately.
30. Did the facility fail to notify regional DWQ of emergency situations as required by Permit,
❑
0 ❑ ❑
(i.e., discharge, freeboard problems, over -application)
31. Do subsurface tile drains exist at the facility?
❑
0 ❑ ❑
If yes, check the appropriate box below.
Application Field
❑
Lagoon / Storage Pond
❑
Other
❑
If Other, please specify
32. Were any additional problems noted which cause non-compliance of the Permit or
❑
0 ❑ ❑
CAW M P?
33. Did the Reviewer/Inspector fail to discuss review/inspection with on -site representative?
❑
0 ❑ ❑
34. Does the facility require a follow-up visit by same agency?
❑
0 ❑ ❑
Page 5 of 5