Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
310039_Compliance Report_20230613
F- . 71 ANALYTICAL & CONSULTING CHEMISTS Environmental Chemists, Inc. 6602 Windmill Way, Wilmington, NC 28405 • 910.392.0223 Lab ■ 910.392.4424 Fax 710 Bowsertown Road, Manteo, NC 27954 . 252.473.5702 Lab/Fax 255-A Wilmington Highway, Jacksonville, NC 28540 ■ 910.347.5843 Lab/Fax info(a environmentalchemismcom Smithfield Hog Productions -Warsaw Date of Report: May 01, 2023 Post Office Box 856 Customer PO #: Warsaw NC 28398 Customer ID: 08110011 Attention: Report #: 2023-06606 Project ID: Benson Digester 2026 Lab ID Sample ID: Collect DatelTime Matrix Sampled by 23-16671 Site: Influent 4/5/2023 11:05 AM Water Derek Brown Test Method Results Date Analyzed Sulfur EPA 200.7 62.3 mg/i_ 04/27/2023 Copper EPA 200.7. Rev 4.4, 1994 5.13 mg/L 04/07/2023 Zinc EPA 200.7, Rev 4.4, 1994 4.90 mg/L 04/07/2023 Fecal Coliform Idera Colilert-18 >241960 MPN/100mi 04/05/2023 Ammonia Nitrogen SM 4500 NH3 C-2011 420 mg/L 04/06/2023 Total Phosphorus SM 4500 P (F-H).2011 238 mg/L 04/12/2023 Total Nitrogen (Cale) Nitrate+Nitrite-Nitrogen EPA 353.2, Rev, 2.0. 1993 2.02 mg/L 04/06/2023 Total Kjeldahl Nitrogen (TKN) SM 4500 Norg B-201 1 637mg/L 04/06/2023 Total Nitrogen Total Nitrogen 639 mg/L 04/14/2023 Lab ID Sample ID: Collect Date/Time Matrix Sampled by 23-16673 Site: Effluent 4/5/2023 10:55 AM Water Derek Brown Test Method Results Date Analyzed Sulfur EPA 200.7 55.2 mg/L 04/27/2023 Copper EPA 200.7, Rev 4.4, 1994 6.78 mg/L 04/07/2023 Zinc EPA 200.7, Rev 4 4. 1994 6.65 mg/L 04/07/2023 Fecal Coliform Idexx Colilelt-16 >241960 MPN/100mi 04/05/2023 Ammonia Nitrogen SM 4500 NH3 C-2011 990 mg/L 04/06/2023 Total Phosphorus SM 4500 P (F-H)-2011 136 mg/L 04/12/2023 Total Nitrogen (Cale) Nitrate+Nitrite-Nitrogen EPA 353.2, Rev 2.0, 1993 2.73 mg/L 04/06/2023 Total Kjeldahl Nitrogen (TKN) SM 4500 Norg B-2o11 1310 mg/L 04/06/2023 Total Nitrogen Total Nitrogen 1320 mg/L 04/14/2023 Comment: Reviewed by: Report #:: 2023-06606 Page 1 of 1 Environmental Chemist, Inc., Wilmington, INC Lab #94 Sample Receipt Checklist 6602 Windmill Way Wilmington, NC 28405 910.392.0223 Client:..�.k Y k_ I Date: Report Number: 2 3 `" Q(ob Receipt of sample: Echem Pick up Client Delivery © UPS ❑ FeclEx ❑ Other ❑ ❑ YES 10 NO N/Al 1. Were custody seals present on the cooler? ❑ YES 10 NO N/Al dco 12, If custody seals were present, were they intact/unbroken? Original temperature upon receipt °C Corrected temperature upon receipt °C How temperature taken: ❑ Temperature Blank V Against Bottles IR Gun ID: Thomas Traceable S/N 192511657 IR Gun Correction Factor °C: 0.0 ❑ YES ❑ NO 3. If temperature of cooler exceeded 6°C, was Project Mgr./QA notified? YES ❑ NO 4. Were proper custody procedures (relinquished/received) followed? YES ❑ NO 5. Were sample ID's listed on the COC? YES ❑ NO 6. Were samples ID's listed on sample containers? YES ❑ NO 7. Were collection date and time listed on the COC? YES ❑ NO 8. Were tests to be performed listed on the COC? YES ❑ NO 9. Did samples arrive in proper containers for each test? ML YES ❑ NO 10. Did samples arrive in good condition for each test? YES ❑ NO 11. Was adequate sample volume available?' YES ❑ NO 12. Were samples received within proper holding time for requested tests? YES ❑ NO 13. Were acid preserved samples received at a pH of <2? ❑ YES ❑ NO 14. Were cyanide samples received at a pH >12? ❑ YES ❑ NO 15. Were sulfide samples received at a pH >9? YES ❑ NO 16. Were NH3/TKN/Phenol received at a chlorine residual of <0.5 m/L? ** ❑ YES ❑ NO 17. Were Sulfide/Cyanide received at a chlorine residual of <0.5 m/L? ❑ YES 10 NO 18, Were orthophosphate samples filtered in field within 15 minutes? * TOC/Volatiles are pH checked at time of analysis and recorded on the benchsheet. ** Bacteria samples are checked for Chlorine at time of analysis and recorded on the benchsheet. Sample Preservation (Must be completed for any sample(s) incorrectly preserved or with headspace) Sample(s) were received incorrectly preserved and were adjusted accordingly by adding (circle one): HZSO4 HNO3 HCI NaOH Time of preservation: If more than one preservative is needed, notate in comments below Note: Notify customer service immediately for incorrectly preserved samples. Obtain a new sample or notify the state lab if directed to analyzed by the customer. Who was notified, date and time: Volatiles Sample(s) were received with headspace COMMENTS: DOC.QA.002 Rev 1 = c m rn 6-- 0• 7 ki 0 O � 3 � O w � � t➢ Sample Type Composite D0D000006)0000000 D G)0 or Grab � -0 -0 M Container iL (P or G) v Chlorine m mgfL 3 fp �� LAB ID NUMBER NONE HCL y M X X H2SO4 M N X X HNO3 C C NAOH CIS Q. w THIO Z X X OTHER O Z O O Z N (D cl) — Z _ = z O C r N N y rn O n n m m c � y 3 0) M v v v � � 3 M N 3 0. 2 O O. O O m O M a m ° a m a M m N O N O1 �" fd ra z 3 = O Z O Z O m a O `I Z O rn zZ rn M M DD 0 Z m a 1 aZ zz �aA 0r O M M " N O r rn N rn m r n (h O 'w z `/� � V w �n Z 0