Loading...
HomeMy WebLinkAboutSW3230303_O&M Agreement/Plan_20230613Operations& Maintenance Agreement 1@= Cover Page Maintenance records shall be kept on the following SCM(s). This maintenance record shall be kept in a log in a known set location. Any deficient SCM elements noted in the inspection will be corrected, repaired, or replaced immediately. These deficiencies can affect the integrity of structures, safety of the public, and the pollutant removal efficiency of the SCM(s). The SCM(s) on this project include (check all that apply & co Infiltration Basin Quantity: Infiltration Trench, Quantity: Bioretention Cell Quantity: Wet Pond Quantity: Stormwater Wetland Quantity: Permeable Pavement Quantity; Sand Fifter Quantity: Rainwater Harvesting Quantity: Green Roof Quantity: Level Spreader - Filter Strip Quantity: Proprietary System Quantity: Treatment Swale Quantity: Dry Pond Quantity: Disconnected Impervious Surface Present*. User Defined SCM Present: Low Density Present:: respondii g O&M sheets will Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s), Location(s): Location(s): Locafion(s): Type: be added automatically): 0 0 0 0 0 0 0 0 0 it 0 a 0 No No Dispersed flow only Yes I acknowledge and agree by my signature below that I am responsible for the performance of the maintenance procedures listed for each SCM above, and attached O&M tables, I agree to notify NCDEQ of any problems with the system or prior to any changes to the system or responsible party. Responsible Party: Title & Organization: Street address: City, state, zip: Phone number(s): Email: Union County Water Thomas Mann P.E. 500 N Main Street, Suite 600 Monroe, NC 28112 17042922560 ithomas.rnann@unioncountync.gov Signature: Ile Date: 3'- ly- 2.3 1�115- /9-Y 'I ZL.Z?ey a Notary Public for the State of County of ZZ do hereby certify that personally appeared before me this day of '-d a Z1,2''I and acknowledge the due execution of the Oiati Ps t rainten nce Agreement Witness my, harl 0 official seal, Yb t 2i a cou commission expires MY COMWANIon Expkes 1 011'712025 My co Seal STORM-EZ Version 1.5 O&M Agreement 3114/2023 Page 1 of 1 Operation & Maintenance Manual Important maintenance procedures: The drainage area to the vegetated conveyance or vegetated receiving area will be carefully managed to reduce the sediment load to the vegetated conveyance or vegetated receiving area. After the initial fertilization to establish the grass in the vegetated conveyance or the vegetated receiving area, fertilizer will not be applied to the vegetated receiving areas. The vegetated conveyance or vegetated receiving area will be inspected quarterly. Records of operation and maintenance will be kept in a known set location and will be available upon request. Inspection activities shall be performed as follows. Any problems that are found shall be repaired immediately. SCM element: Potential problem: How to remediate the problem: Vegetation Vegetation is too short or Maintain grassed vegetation such that the swale or vegetated too long. area does not erode during the peak flow from the 10-year storm Trash/debris is present. Remove the trash/debris. Areas of bare soil and/or Regrade the soil if necessary to remove the gully, and then re -sod Vegetated receiving areas erosive gullies have (or plant with other appropriate species) and water until formed. established. Provide lime and a one-time fertilizer application. Clogging has occurred. Clean out the outlet device. Dispose of the sediment off -site. The outlet device (if applicable) The outlet device is Repair or replace the outlet device. damaged Erosion or other signs of damage have occurred at Repair the damage and improve the flow dissipation structure. the outlet. Discharges from the site The receiving water are causing erosion or Contact the local NCDEQ Regional Office. sedimentation in the receiving water. Appendix F Wetland Certification Statement