HomeMy WebLinkAboutWQ0001664_Monitoring - 03-2023_20230417 (2)Monitoring Report Submittal
Permit Number#* WQ0001664
Name of Facility:* Belvedere Plantations WWTF
Month: * March Year: * 2023
Report Information
Type* Upload Document*
NDMR, NDAR-1, NDAR-2, NDMLR Belvedere WWTP March 2023 DMR.pdf 8.06MB
PDF Only
GW-59 Belvedere March 2023 MW Reports.pdf 12.14MB
PDF Only
Please upload one PDF containing all applicable monitoring reports
(i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59).
Confirmation Email Address: * greg.spillman@carolinawaterservicenc.com
Name of Submitter: * Greg Spillman
Signature:
Date of submittal: 4/17/2023
This will be filled in automatically
Initial Review
Reviewer: Wanda.Gerald
Is the project number correct?* WQ0001664
Is the monitoring report accepted?* Yes NO
Regional Office* Wilmington
Reviewer: _anonymous
Review Date: 6/13/2023
SUBMIT FORM ON YELLOW PAPER ONLY
GROUNDWATER QUALITY MONITORING:
• •
DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES
DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT
COMPLIANCE REPORT FORM
• • •
•
1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306
FACILITY INFORMATION
Please Print Clearly or Type
PERMIT Number: Expiration Date: 3/31/2026
Facility Name:
Belvedere Plantation
Non -Discharge WQ0001664 UIC
Permit Name (if different):
NPDES Other
Facility Address: 130 Fairway Dr
Hampstead N.C. 28443
TYPE OF PERMITTED OPERATION BEING MONITORED
County Pender
❑ Lagoon ❑ Remediation: Infiltration Gallery
❑ Spray Field ❑ Remediation:
Contact Person: Greg Spillman
Telephone#: 252-241-0661
❑ Rotary Distributor ❑ Land Application of Sludge
Well Location/Site Name # 3 Green
No. of wells to be sampled: 9
❑ Water Source Heat Pump ❑ Other: INFILTRATION BASIN
from Permit
SAMPLING INFORMATION
If WELL
WELL ID NUMBER (from Permit): MW7
Date sample collected: 3/1/2023
FIELD ANALYSES:
WAS
Well Depth: 17 ft.
Well Diameter: 2 in.
pH 00400: 5.7 units Temp. 000lc 177 oC
DRY at
Depth to Water Level 82546: 5
Screened Interval: 5 ft. to
15 ft. Spec. Cond. 00094: µMhos
time of
Measuring Point is 3 ft. above land surface
Relative M.P. Elevation: ft.
Odor 000s5: None
sampling,
check
Volume of water pumped/bailed before sampling:
4
gallons
Appearance light red
here:❑
Samples for metals were collected unfiltered: ❑ YES
❑ NO and field acidified: ❑ YES ❑ NO
LABORATORY INFORMATION
Date sample analyzed. 3/1/2023
Laboratory Name: Environmental Chemists, Inc. Certification No. 94
PARAMETERS NOTE: Values should reflect
dissolved
and colloidal concentrations.
COD 00335
mg/L
Nitrite (NO2) as N 00615 0.03
mg/L Pb - Lead 01051 ug/L
Coliform: MF Fecal 31616 <1
/100mL
Nitrate (NO3) as N 00620 0.07
mg/L Zn - Zinc 01092 mg/L
Coliform: MF Total 31504
/100mL
Phosphorus: Total as P 00665 0.44
mg/L
(Note: Use MPN method for highly turbid samples)
Orthophosphate 70507
mg/L Other (Specify Compounds and Concentration Units):
Dissolved Solids:Total 70300 101
mg/L
Al - Aluminum 01105
mg/L
pH (Lab) 00403 5.7
units
Ba - Barium 01007
ug/L
TOC 00680
mg/L
Ca - Calcium 00916
mg/L
Chloride 00940 13
mg/L
Cd - Cadmium 01027
ug/L
Arsenic 01002
ug/L
Chromium: Total 01034
ug/L
Grease and Oils 00552
mg/L
Cu - Copper 01042
mg/L ORGANICS: (by GC, GC/MS, HPLC)
Phenol 32730
ug/L
Fe - Iron 01045
ug/L (Specify test and method #. ATTACH LAB REPORT.)
Sulfate 00945
mg/L
Hg - Mercury 71900
ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0)
pecific Conductance 00095
µMhos
K - Potassium 00937
mg/L VOC 7873 method #
Total Ammonia 00610 <0.2
mg/L
Mg - Magnesium 00927
mg/L method #
(Ammonia Nitrogen: NH3as N. Ammonia Nitrogen, Total)
Mn -Manganese 01055
uglL ,method #
TKN as N 00625
mg/L
Ni - Nickel 01067
ug/L method #
For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal%
Carolina Water Service of NC - Tony Konsul - Director,State Operations
Permittee (or Authorized Agent) Name and Title - Please print or type
Tony Konsul Io.NC280sa.ese eo,
Signature of Permittee (or Authorized Aqent) (Date)
GW-59 Rev.8/2013
SUBMIT FORM ON YELLOW PAPER ONLY
GROUNDWATER QUALITY MONITORING:
• •
DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES
DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT
COMPLIANCE REPORT FORM
• • •
•
1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306
FACILITY INFORMATION Please Print Clearly or Type
PERMIT Number: Expiration Date: 3/31/2026
Facility Name: Belvedere Plantation
Non -Discharge WQ0001664 UIC
Permit Name (if different):
NPDES Other
Facility Address: 130 Fairway Dr
Hampstead N.C. 28443
TYPE OF PERMITTED OPERATION BEING MONITORED
❑ Lagoon ❑ Remediation: Infiltration Gallery
County Pender
❑ Spray Field ❑ Remediation:
Contact Person: Greg Spillman
Telephone#: 252-241-0661
❑ Rotary Distributor ❑ Land Application of Sludge
Well Location/Site Name # 7 Green
No. of wells to be sampled: 9
❑ Water Source Heat Pump ❑ Other: INFILTRATION BASINS
from Permit
SAMPLING INFORMATION
If WELL
WELL ID NUMBER (from Permit): MW8
Date sample collected: 3/1/2023
FIELD ANALYSES:
WAS
Well Depth: 18 ft.
Well Diameter: 2 in.
pH 00400: 6.9 units Temp. 0001c 204 OC
DRY at
Depth to Water Level 82546: 9
Screened Interval: 5 ft. to
15 ft. Spec. Cond. 00094: µMhos
time of
Measuring Point is 3 ft. above land surface
Relative M.P. Elevation: ft.
Odor 00085: None
sampling,
check
Volume of water pumped/bailed before sampling: 5
gallons
Appearance tan
here:
Samples for metals were collected unfiltered: ❑ YES
❑ NO and field acidified: ❑ YES ❑ NO
LABORATORY INFORMATION
Date sample analyzed: 3/1/2023
Laboratory Name: Environmental
Chemists, Inc. Certification No. 94
PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations.
COD 00335 mg/L
Nitrite (NO2) as N 00615 0.06
mg/L Pb - Lead o1o51 ug/L
Coliform: MF Fecal 31616 <1 /100mL
Nitrate (NO3) as N 00620 0.57
mg/L Zn - Zinc 01092 mg/L
Coliform: MF Total 31504 /100mL
Phosphorus: Total as P 00665 2.06
mg/L
(Note: Use MPN method for highly turbid samples)
Orthophosphate 70507
mg/L Other (Specify Compounds and Concentration Units):
issolved Solids:Total 70300 266 mg/L
Al -Aluminum 01105
mg/L
pH (Lab) 00403 6.9 units
Ba - Barium 01007
ug/L
TOC 00680 mg/L
Ca - Calcium 00916
mg/L
Chloride 00940 11 mg/L
Cd - Cadmium 01027
ug/L
Arsenic 01002 ug/L
Chromium: Total 01034
ug/L
Grease and Oils 00552 mg/L
Cu - Copper 01042
mg/L ORGANICS: (by GC, GC/MS, HPLC)
Phenol 32730 ug/L
Fe - Iron 01045
ug/L (Specify test and method #. ATTACH LAB REPORT.)
Sulfate 00945 mg/L
Hg - Mercury 71900
ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0)
Specific Conductance 00095 µMhos
K - Potassium 00937
mg/L VOC 7873 method #
Total Ammonia 00610 <0.2 mg/L
Mg - Magnesium 00927
mg/L method #
(Ammonia Nitrogen; NH3as N, Ammonia Nitrogen, Total)
Mn - Manganese 01055
ug/L method #
TKN as N 00625 mg/L
Ni - Nickel 01067
ug/L method #
For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal%
Permittee (or Authorized Aqent) Name and Title - Please print or type
GW-59 Rev.8/2013
laf AUmorizea Ageml
t"dMi
SUBMIT FORM ON YELLOW PAPER ONLY
• •
DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES
GROUNDWATER QUALITY MONITORING:
DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT
COMPLIANCE REPORT FORM
• • •
•
1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306
FACILITY INFORMATION
Please Print Clearly or Type
PERMIT Number: Expiration Date: 3/31/2026
Facility Name:
Belvedere Plantation
Non -Discharge WQ0001664 UIC
NPDES Other
Permit Name (if different):
Facility Address: 130 Fairway
Dr
Hampstead N.C. 28443
TYPE OF PERMITTED OPERATION BEING MONITORED
❑ Lagoon ❑ Remediation: Infiltration Gallery
County Pender
❑ Spray Field ❑ Remediation:
Contact Person: Greg Spillman
Telephone#: 252-241-0661
❑ Rotary Distributor ❑ Land Application of Sludge
Well Location/Site Name # 3 Green near woods
No. of wells to be sampled: 9
❑ Water Source Heat Pump ❑ Other: INFILTRATION BASINS
from Permit
SAMPLING INFORMATION
If WELL
WELL ID NUMBER (from Permit): MW9
Date sample collected: 3/1/2023
FIELD ANALYSES:
WAS
Well Depth: 23 ft.
Well Diameter: 2 in.
pH 00400: 5.6 units Temp. 000lc 198 °C
DRY at
Depth to Water Level 82546: 18
Screened Interval: 5 ft. to
15 ft. Spec. Cond. 00094: ltMhos
time of
Measuring Point is 3 ft. above land surface
Relative M.P. Elevation: ft.
Odor 000a5: None
sampling,
check
Volume of water pumped/bailed before sampling:
5
gallons
Appearance tan
here:
❑
Samples for metals were collected unfiltered: ❑ YES
El NO and field acidified: El YES El NO
LABORATORY INFORMATION
Date sample analyzed: 3/1/2023
Laboratory Name: Environmental Chemists, Inc. Certification No. 94
PARAMETERS NOTE: Values should reflect
dissolved and colloidal concentrations.
COD 00335
mg/L
Nitrite (NO2) as N 00615 0.27
mg/L Pb - Lead 01051 ug/L
Coliform: MF Fecal 31616 <1
/100mL
Nitrate (NO3) as N 00620 0.76
mg/L Zn - Zinc 01092 mg/L
Coliform: MF Total 31504
/100mL
Phosphorus: Total as P 00665 1.28
mg/L
(Note: Use MPN method for highly turbid samples)
Orthophosphate 70507
mg/L Other (Specify Compounds and Concentration Units):
issolved Solids:Total 70300 443
mg/L
Al - Aluminum 01105
mg/L
pH (Lab) 00403 5.6
units
Ba - Barium 01007
ug/L
TOC omm
mg/L
Ca - Calcium 00916
mg/L
Chloride 00940 68
mg/L
Cd - Cadmium 01027
ug/L
Arsenic 01002
ug/L
Chromium: Total 01034
ug/L
Grease and Oils 00552
mg/L
Cu - Copper 01042
mg/L ORGANICS: (by GC, GC/MS, HPLC)
Phenol 32730
ug/L
Fe - Iron 01045
ug/L (Specify test and method #. ATTACH LAB REPORT.)
Sulfate 00945
mg/L
Hg - Mercury 71900
ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0)
pecific Conductance 00095
µMhos
K - Potassium 00937
mg/L VOC 7873 method #
Total Ammonia 00610 <0.2
mg/L
Mg - Magnesium 00927
mg/L method #
(Ammonia Nitrogen; NH3as N, Ammonia Nitrogen, Total)
Mn - Manganese 01055
ug/L method #
TKN as N 00625
mg/L
Ni - Nickel 01067
ug/L method #
For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal%
Permittee (or Authorized Aqent) Name and Title - Please print or type Siqnature of Permittee (or Authorized Aqent) (Date)
GW-59 Rev.8/2013
SUBMIT FORM ON YELLOW PAPER ONLY
GROUNDWATER QUALITY MONITORING:
• •
DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES
DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT
COMPLIANCE REPORT FORM
• • •
•
1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306
FACILITY INFORMATION
Please Print Clearly or Type
PERMIT Number: Expiration Date: 3/31/2026
Facility Name:
Belvedere Plantation
Non -Discharge WQ0001664 UIC
NPDES Other
Permit Name (if different)
Facility Address:
130 Fairway Dr
Hampstead N.C. 28443
TYPE OF PERMITTED OPERATION BEING MONITORED
❑ Lagoon ❑ Remediation: Infiltration Gallery
County Pender
❑ Spray Field ❑ Remediation:
Contact Person:
Greg Spillman
Telephone#: 252-241-0661
❑ Rotary Distributor ❑ Land Application of Sludge
Well Location/Site Name
# 3 green near tee box
No. of wells to be sampled: 9
❑ Water Source Heat Pump ❑ Other: INFILTRATION BASINS
from Permit
SAMPLING INFORMATION
If WELL
WELL ID NUMBER (from Permit):
MW10
Date sample collected: 3/1/2023
FIELD ANALYSES:
WAS
Well Depth: 18 ft.
Well Diameter: 2 in.
pH 00400: 6.4 units Temp. 000lc 18 °C
DRY at
Depth to Water Level 82546: 5.6
ft. below measuring point Screened Interval: 5 ft. to
15 ft. Spec. Cond. 00094: µMhos
time of
Measuring Point is 3 ft.
above land surface
Relative M.P. Elevation: ft.
Odor 000as: None
sampling,
check
Volume of water pumped/bailed before sampling: 5
gallons
Appearance light tan
here:❑
Samples for metals were collected
unfiltered: ❑ YES
❑ NO and field acidified: ❑ YES ❑ NO
LABORATORY INFORMATION
Date sample analyzed
3/1/2023
Laboratory Name: Environmental Chemists, Inc. Certification No. 94
PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations.
COD 00335
mg/L
Nitrite (NO2) as N 00615 0.16
mg/L Pb - Lead o1o51 ug/L
Coliform: MF Fecal 31616
<1 /100mL
Nitrate (NO3) as N 00620 2.09
mg/L Zn - Zinc 01092 mg/L
Coliform: MF Total 31504
/100mL
Phosphorus: Total as P 00665 2.01
mg/L
(Note: Use MPN method for highly turbid
samples)
Orthophosphate 70507
mg/L Other (Specify Compounds and Concentration Units):
issolved Solids:Total 70300
115 mg/L
Al - Aluminum 01105
mg/L
pH (Lab) 00403
6.4 units
Ba - Barium 01007
ug/L
TOC 00680
mg/L
Ca - Calcium 00916
mg/L
Chloride 00940
12 mg/L
Cd - Cadmium 01027
ug/L
Arsenic 01002
ug/L
Chromium: Total 01034
ug/L
Grease and Oils 00552
mg/L
Cu - Copper 01042
mg/L ORGANICS: (by GC, GC/MS, HPLC)
Phenol 32730
ug/L
Fe - Iron 01045
ug/L (Specify test and method #. ATTACH LAB REPORT.)
Sulfate o0945
mg/L
Hg - Mercury 71900
ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0)
Specific Conductance 00095
µMhos
K - Potassium 00937
mg/L VOC 7873 method #
Total Ammonia 00610
<0.2 mg/L
Mg - Magnesium 00927
mg/L method #
(Ammonia Nitrogen: NH3 as N: Ammonia
Nitrogen, Total)
Mn - Manganese 01055
ug/L method #
TKN as N 00625
mg/L
Ni - Nickel 01067
ug/L method #
For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal%
Carolina Water Service of NC - Tony Konsul - Director,State Operations
Permittee (or Authorized Aqent) Name and Title - Please print or type
GW-59 Rev.8/2013
Tony Konsul
Siqnature of Permittee (or Authorized Agent) (Date)
SUBMIT FORM ON YELLOW PAPER ONLY
GROUNDWATER QUALITY MONITORING:
♦ ♦
DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES
DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT
COMPLIANCE REPORT FORM
♦ ♦ ♦
♦
1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919.807-6306
FACILITY INFORMATION
Please Print
Clearly or Type
PERMIT Number: Expiration Date: 3/31/2026
Facility Name:
Belvedere Plantation
Non -Discharge WQ0001664 UIC
NPDES Other
Permit Name (if different).
Facility Address: 130 Fairway
Dr
Hampstead N.C. 28443
TYPE OF PERMITTED OPERATION BEING MONITORED
❑ Lagoon ❑ Remediation: Infiltration Gallery
County Pender
❑ Spray Field ❑ Remediation:
Contact Person: Greg Spillman
Telephone#: 252-241-0661
❑ Rotary Distributor ❑ Land Application of Sludge
Well Location/Site Name Basin A right corner
No. of wells to be sampled: 9
❑ Water Source Heat Pump ❑ Other: INFLITRATION BASINS
from Permit
SAMPLING INFORMATION
If WELL
WELL ID NUMBER (from Permit): MW11
Date sample collected: 3/1/2023
FIELD ANALYSES:
WAS
Well Depth: 15 ft.
Well Diameter: 2 in.
pH 00400: 4.5 units Temp. 000lc 183 °C
DRY at
Depth to Water Level 82546: 14
Screened Interval: 5 ft. to
15 ft. Spec. Cond. 00094: µMhos
time of
Measuring Point is 3 ft. above land surface
Relative M.P. Elevation: ft.
Odor 00085: none
sampling,
check
Volume of water pumped/bailed before sampling:
5
gallons
Appearance light brown
here:❑
Samples for metals were collected unfiltered: ❑ YES
❑ NO and field acidified: ❑ YES ❑ NO
LABORATORY INFORMATION
Date sample analyzed: 3/1/2023
Laboratory Name: Environmental Chemists, Inc. Certification No. 94
PARAMETERS NOTE: Values should reflect
dissolved and colloidal concentrations.
COD 00335
mg/L
Nitrite (NO2) as N 00615 <0.02
mg/L Pb - Lead o1o51 ug/L
Coliform: MF Fecal 31616 <1
/100mL
Nitrate (NO3) as N 00620 0.04
mg/L Zn - Zinc 01092 mg/L
Coliform: MF Total 31504
/100mL
Phosphorus: Total as P 00665 0.22
mg/L
(Note: Use MPN method for highly turbid samples)
Orthophosphate 70507
mg/L Other (Specify Compounds and Concentration Units):
Dissolved Solids:Total 70300 46
mg/L
Al - Aluminum 01105
mg/L
pH (Lab) 00403 4.5
units
Ba - Barium 01007
ug/L
TOC 00680
mg/L
Ca - Calcium 00916
mg/L
Chloride 00940 14
mg/L
Cd - Cadmium 01027
ug/L
Arsenic 01002
ug/L
Chromium: Total 01034
ug/L
Grease and Oils 00552
mg/L
Cu - Copper 01042
mg/L ORGANICS: (by GC, GC/MS, HPLC)
Phenol 32730
ug/L
Fe - Iron 01045
ug/L (Specify test and method #. ATTACH LAB REPORT.)
Sulfate 00945
mg/L
Hg - Mercury 71900
ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0)
pecific Conductance 00095
µMhos
K - Potassium 00937
mg/L VOC 7873 method #
Total Ammonia 00610 <0.2
mg/L
Mg - Magnesium 00927
mg/L method #
(Ammonia Nitrogen; NH3 as N, Ammonia Nitrogen, Total)
Mn -Manganese 01055
ug/L ,method #
TKN as N 00625
mg/L
Ni - Nickel 01067
ug/L method #
For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal%
Carolina Water Service of NC - Tony Konsul - Director,State Operations
Permittee (or Authorized Aqent) Name and Title - Please print or type
GW-59 Rev.8/2013
Tony Konsul = oe1�2a 9ae,se
Siqnature of Permittee (or Authorized Agent) (Date)
SUBMIT FORM ON YELLOW PAPER ONLY
GROUNDWATER QUALITY MONITORING:
• •
DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES
• • •
•
DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT
COMPLIANCE REPORT FORM
1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306
FACILITY INFORMATION
Please Print Clearly or Type
PERMIT Number: Expiration Date: 3/31/2026
Facility Name:
Belvedere Plantation
Non -Discharge WQ0001664 UIC
NPDES Other
Permit Name (if different):
Facility Address: 130 Fairway Dr
Hampstead N.C. 28443
TYPE OF PERMITTED OPERATION BEING MONITORED
❑ Lagoon ❑ Remediation: Infiltration Gallery
County Pender
❑ Spray Field ❑ Remediation:
Contact Person: Greg Spillman
Telephone#: 252-241-0661
❑ Rotary Distributor ❑ Land Application of Sludge
Well Location/Site Name Back of Basin B
No. of wells to be sampled: 9
❑ Water Source Heat Pump ❑ Other: INFILTRATION BASINS
from Permit
SAMPLING INFORMATION
If WELL
WELL ID NUMBER (from Permit): MW12
Date sample collected: 3/1/2023
FIELD ANALYSES:
WAS
Well Depth: 15 ft.
Well Diameter: 2 in.
pH 00400. 5 units Temp. 000lc 18 °C
DRY at
Depth to Water Level 82546: 11
Screened Interval: 5 ft. to
15 ft. Spec. Cond. 00094i µMhos
time of
Measuring Point is 3 ft. above land surface
Relative M.P. Elevation: ft.
Odor 00085: Sulfur
sampling,
check
Volume of water pumped/bailed before sampling:
5
gallons
Appearance tan
here:❑
Samples for metals were collected unfiltered: ❑ YES
❑ NO and field acidified: ❑ YES ❑ NO
LABORATORY INFORMATION
Date sample analyzed: 3/1/2023
Laboratory Name: Environmental Chemists, Inc. Certification No. 94
PARAMETERS NOTE: Values should reflect
dissolved and colloidal concentrations.
COD 00335
mg/L
Nitrite (NO2) as N 00615 0.05
mg/L Pb - Lead 01051 ug/L
Coliform: MF Fecal 31616 <1
/100mL
Nitrate (NO3) as N 00620 0.02
mg/L Zn - Zinc 01092 mg/L
Coliform: MF Total 31504
/100mL
Phosphorus: Total as P 00665 0.14
mg/L
(Note: Use MPN method for highly turbid samples)
Orthophosphate 70507
mg/L Other (Specify Compounds and Concentration Units):
issolved Solids:Total 70300 247
mg/L
Al - Aluminum of lo5
mg/L
pH (Lab) 00403 5
units
Ba - Barium 01007
ug/L
TOC 00680
mg/L
Ca - Calcium 00916
mg/L M
Chloride 00940 68
mg/L
Cd - Cadmium 01027
ug/L
Arsenic 01002
ug/L
Chromium: Total 01034
ug/L
Grease and Oils 00552
mg/L
Cu - Copper 01042
mg/L ORGANICS: (by GC, GC/MS, HPLC)
Phenol 32730
ug/L
Fe - Iron 01045
ug/L (Specify test and method #. ATTACH LAB REPORT.)
Sulfate 00945
mg/L
Hg - Mercury 71900
ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0)
pecific Conductance 00095
µMhos
K - Potassium 00937
mg/L VOC 7873 method #
Total Ammonia omio 0.7
mg/L
Mg - Magnesium 00927
mg/L method #
(Ammonia Nitrogen: NH3as N; Ammonia Nitrogen, Total)
Mn -Manganese 01055
ug/L ,method #
TKN as N 00625
mg/L
Ni - Nickel 01067
ug/L method #
For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs:
Carolina Water Service of NC - Tony Konsul - Director,State Operations To n v Ko n s u l
Permittee (or Authorized Aqent) Name and Title - Please print or type Siqnature of Permittee (or Authorized Agent)
GW-59 Rev.8/2013
NOTION •
)d methods of analysis by a
I �I .
SUBMIT FORM ON YELLOW PAPER ONLY
GROUNDWATER QUALITY MONITORING:
• •
DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES
DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT
COMPLIANCE REPORT FORM
• • •
•
1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306
FACILITY INFORMATION
Please Print Clearly or Type
PERMIT Number: Expiration Date: 3/31/2026
Facility Name:
Belvedere Plantation
Non -Discharge WQ0001664 UIC
Permit Name (if different):
NPDES Other
Facility Address: 130 Fairway Dr
Hampstead N.C. 28443
TYPE OF PERMITTED OPERATION BEING MONITORED
❑ Lagoon ❑ Remediation: Infiltration Gallery
County Pender
❑ Spray Field ❑ Remediation:
Contact Person: Greg Spillman
Telephone#: 252-241-0661
❑ Rotary Distributor ❑ Land Application of Sludge
Well Location/Site Name 1 st Basin C near front right corner No. of wells to be sampled: 9
❑ Water Source Heat Pump ❑ Other: INFILTRATION BASINS
from Permit)
SAMPLING INFORMATION
If WELL
WELL ID NUMBER (from Permit): MW13
Date sample collected: 3/1/2023
FIELD ANALYSES:
WAS
Well Depth: 15 ft.
Well Diameter: 2 in.
pH 00400: 4.7 units Temp. 000i( 19.6 °C
DRY at
Depth to Water Level 82546: 13
Screened Interval: 5 ft. to
15 ft. Spec. Cond. 00094: µMhos
time of.
Measuring Point is 3 ft. above land surface
Relative M.P. Elevation: ft.
Odor o0085: slight sulfur
sampling,
check
Volume of water pumped/bailed before sampling:
5
gallons
Appearance light brown
here:❑
Samples for metals were collected unfiltered: ❑ YES
❑ NO and field acidified: ❑ YES ❑ NO
LABORATORY INFORMATION
Date sample analyzed: 3/1/2023
Laboratory Name: Environmental Chemists, Inc. Certification No. 94
PARAMETERS NOTE: Values should reflect
dissolved and colloidal concentrations.
COD 00335
mg/L
Nitrite (NO2) as N 00615 <0.02
mg/L Pb - Lead 01051 ug/L
Coliform: MF Fecal 31616 <1
/100mL
Nitrate (NO3) as N 00620 <0.02
mg/L Zn - Zinc 01092 mg/L
Coliform: MF Total 31504
/100mL
Phosphorus: Total as P 00665 0.37
mg/L
(Note: Use MPN method for highly turbid samples)
Orthophosphate 70507
mg/L Other (Specify Compounds and Concentration Units):
issolved Solids:Total 70300 35
mg/L
Al - Aluminum 01105
mg/L
pH (Lab) 00403 4.7
units
Ba - Barium 01007
ug/L
TOC 00680
mg/L
Ca - Calcium 00916
mg/L
Chloride 00940 <5
mg/L
Cd - Cadmium 01027
ug/L
Arsenic 01002
ug/L
Chromium: Total 01034
ug/L
Grease and Oils 00552
mg/L
Cu - Copper 01042
mg/L ORGANICS: (by GC, GC/MS, HPLC)
Phenol 32730
ug/L
Fe - Iron 01045
ug/L (Specify test and method #. ATTACH LAB REPORT.)
Sulfate 00945
mg/L
Hg - Mercury 71900
ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0)
pecific Conductance 00095
µMhos
K - Potassium 00937
mg/L VOC 7873 method #
Total Ammonia 00610 <0.2
mg/L
Mg - Magnesium 00927
mg/L method #
(Ammonia Nitrogen, NH3 as N: Ammonia Nitrogen, Total)
Mn - Manganese 01055
ug/L method #
TKN as N 00625
mg/L
Ni - Nickel 01067
ug/L method #
For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal%
Carolina Water Service of NC - Tony Konsul - Director,State Operations
Permittee (or Authorized Aqent) Name and Title - Please print or type
GW-59 Rev.8/2013
Tony Konsul
Siqnature of Permittee (or Authorized Agent)
(Date)
SUBMIT FORM ON YELLOW PAPER ONLY
GROUNDWATER QUALITY MONITORING:
• •
DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES
DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT
COMPLIANCE REPORT FORM
• • •
•
1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306
FACILITY INFORMATION Please Print Clearly or Type
PERMIT Number: Expiration Date: 3/31/2026
Facility Name: Belvedere Plantation
Non -Discharge WQ0001664 UIC
NPDES Other
Permit Name (if different):
Facility Address: 130 Fairway Dr
Hampstead N.C. 28443
TYPE OF PERMITTED OPERATION BEING MONITORED
County Pender
❑ Lagoon ❑ Remediation: Infiltration Gallery
❑ Spray Field ❑ Remediation:
Contact Person: Greg Spillman
Telephone#: 252-241-0661
❑ Rotary Distributor ❑ Land Application of Sludge
Well Location/Site Name Basin left corner.
No. of wells to be sampled: 9
❑ Water Source Heat Pump ❑ Other: INFILTRATION BASINS
from Permit
SAMPLING INFORMATION
If WELL
WELL ID NUMBER (from Permit): MW14
Date sample collected: 3/1/2023
FIELD ANALYSES:
WAS
Well Depth: 15 ft.
Well Diameter: 2 in.
pH 00400: 5.1 units Temp. 000lc 182 oC
DRY at
Depth to Water Level 82546: 11 ft. below measuring point Screened Interval: 5 ft. to
15 ft. Spec. Cond. 00094: µMhos
time of
Measuring Point is 3 ft. above land surface
Relative M.P. Elevation: ft.
Odor 00085 slight sulfur
sampling,
check
Volume of water pumped/bailed before sampling: 5
gallons
Appearance light brown
here:
Samples for metals were collected unfiltered: ❑ YES
❑ NO and field acidified: ❑ YES ❑ NO
LABORATORY INFORMATION
Date sample analyzed: 3/1/2023
Laboratory Name: Environmental Chemists, Inc. Certification No. 94
PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations.
COD 00335 mg/L
Nitrite (NO2) as N 00615 0.03
mg/L Pb - Lead 01051 ug/L
Coliform: MF Fecal 31616 <1 /100mL
Nitrate (NO3) as N 00620 <0.02
mg/L Zn - Zinc 01092 mg/L
Coliform: MF Total 31504 /100mL
Phosphorus: Total as P 00665 0.66
mg/L
(Note: Use MPN method for highly turbid samples)
Orthophosphate 70507
mg/L Other (Specify Compounds and Concentration Units):
issolved Solids -.Total 70300 246 mg/L
Al - Aluminum 01105
mg/L
pH (Lab) 00403 5.1 units
Ba - Barium 01007
ug/L
TOC 00680 mg/L
Ca - Calcium oo916
mg/L
Chloride 00940 66 mg/L
Cd - Cadmium 01027
ug/L
Arsenic 01002 ug/L
Chromium: Total 01034
ug/L
Grease and Oils 00552 mg/L
Cu - Copper 01042
mg/L ORGANICS: (by GC, GC/MS, HPLC)
Phenol 32730 ug/L
Fe - Iron 01045
ug/L (Specify test and method #. ATTACH LAB REPORT.)
Sulfate 00945 mg/L
Hg - Mercury 71900
ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0)
pecific Conductance 00095 µMhos
K - Potassium 00937
mg/L VOC 7873 method #
Total Ammonia 00610 0.2 mg/L
Mg - Magnesium 00927
mg/L method #
(Ammonia Nitrogen; NH3as N, Ammonia Nitrogen, Total)
Mn -Manganese 01055
uglL ,method #
TKN as N 00625 mg/L
Ni - Nickel 01067
ug/L method #
For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs:
Carolina Water Service of NC - Tony Konsul - Director,State Operations To ny Ko n s U l
Permittee (or Authorized Aqent) Name and Title - Please print or type Signature of Permittee (or Authorized Aqent)
GW-59 Rev.8/2013
_ mg/L VOC Removal%
,,d methods of analysis by a
(Date)
SUBMIT FORM ON _YELLOW PAPER ONLY
GROUNDWATER QUALITY MONITORING:
• •
DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES
DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT
COMPLIANCE REPORT FORM
• • •
•
1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306
FACILITY INFORMATION
Please Print Clearly or Type
PERMIT Number: Expiration Date: 3/31/2026
Facility Name:
Belvedere Plantation
Non -Discharge WQ0001664 UIC
Permit Name (if different):
NPDES Other
Facility Address: 130 Fairway
Dr
Hampstead N.C. 28443
TYPE OF PERMITTED OPERATION BEING MONITORED
❑ Lagoon ❑ Remediation: Infiltration Gallery
County Pender
❑ Spray Field ❑ Remediation:
Contact Person: Greg Spillman
Telephone#: 252-241-0661
❑ Rotary Distributor ❑ Land Application of Sludge
Well Location/Site Name Between Basin B & C
No. of wells to be sampled: 9
❑ Water Source Heat Pump ❑ Other: INFILTRATION BASINS
from Permit
SAMPLING INFORMATION
If WELL
WELL ID NUMBER (from Permit): MW15
Date sample collected: 3/1/2023
FIELD ANALYSES:
WAS
Well Depth: 18 ft.
Well Diameter: 2 in.
pH 00400: 4.4 units Temp. 000li 184 °C
DRY at
Depth to Water Level 82546: 13
Screened Interval: 5 ft. to
15 ft. Spec. Cond. 00094: µMhos
time of
Measuring Point is 3 ft. above land surface
Relative M.P. Elevation: ft.
Odor 00085 none
sampling,check
Volume of water pumped/bailed before sampling:
5
gallons
Appearance light brown
here:❑
Samples for metals were collected unfiltered: ❑ YES
❑ NO and field acidified: ❑ YES ❑ NO
LABORATORY INFORMATION
Date sample analyzed: 3/1/2023
Laboratory Name: Environmental Chemists, Inc. Certification No. 94
PARAMETERS NOTE: Values should reflect
dissolved and colloidal concentrations.
COD 00335
mg/L
Nitrite (NO2) as N 00615 0.03
mg/L Pb - Lead 01051 ug/L
Coliform: MF Fecal 31616 <1
/100mL
Nitrate (NO3) as N 00620 0.03
mg/L Zn - Zinc 01092 mg/L
Coliform: MF Total 31504
/100mL
Phosphorus: Total as P 00665 1.19
mg/L
(Note: Use MPN method for highly turbid samples)
Orthophosphate 70507
mg/L Other (Specify Compounds and Concentration Units):
Dissolved Solids:Total 70300 55
mg/L
Al - Aluminum 01105
mg/L
pH (Lab) 00403 4.4
units
Ba - Barium 01007
ug/L
TOC 00680
mg/L
Ca - Calcium 00916
mg/L
Chloride 00940 17
mg/L
Cd - Cadmium 01027
ug/L
Arsenic 01002
ug/L
Chromium: Total 01034
ug/L
Grease and Oils 00552
mg/L
Cu - Copper 01042
mg/L ORGANICS: (by GC, GC/MS, HPLC)
Phenol 32730
ug/L
Fe - Iron 01045
ug/L (Specify test and method #. ATTACH LAB REPORT.)
Sulfate 00945
mg/L
Hg - Mercury 71900
ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0)
Specific Conductance 00095
µMhos
K - Potassium 00937
mg/L VOC 7873 method #
Total Ammonia 00610 <0.2
mg/L
Mg - Magnesium 00927
mg/L method #
(Ammonia Nitrogen, NH, as N: Ammonia Nitrogen, Total)
Mn -Manganese 01055
uglL ,method #
TKN as N 00625
mg/L
Ni - Nickel 01067
ug/L method #
For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal%
Carolina Water Service of NC - Tony Konsul - Director,State Operations Tony Ko n S U I e ° aNC ° °s a,a, V-o'Nc cN v =
11
Permittee (or Authorized Aqent) Name and Title - Please print or tvpe Siqnature of Permittee (or Authorized Aqent) (Date)
GW-59 Rev.8/2013