HomeMy WebLinkAbout20230512 Ver 1_More Info Received_20230602 (2)DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
111C13
CHATHAM
RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
CHATHAM COUNTY, NORTH CAROLINA
SCHEDULE OF DRAWINGS
SHEET
NUMBER
SHEET TITLE
G-001
COVER SHEET
G-003
EROSION CONTROL NOTES
C-101
PLAN AND PROFILE FORCEMAIN STA. 10+00
TO
STA.
24+50
C-102
PLAN AND PROFILE FORCEMAIN STA. 24+50
TO
STA.
39+00
G-002
NOTES, ABBREVIATIONS AND LEGEND
C-103
PLAN AND PROFILE FORCEMAIN STA. 39+00
TO
STA.
53+50
C-104
PLAN AND PROFILE FORCEMAIN STA. 53+50
TO
STA.
68+00
C-105
PLAN AND PROFILE FORCEMAIN STA. 68+00
TO
STA.
82+50
C-106
PLAN AND PROFILE FORCEMAIN STA. 82+50
TO
STA.
97+00
C-107
PLAN AND PROFILE FORCEMAIN STA. 97+00
TO
STA.
111+50
C-108
PLAN AND PROFILE FORCEMAIN STA. 111+50
TO
STA.
127+00
C-109
PLAN AND PROFILE FORCEMAIN STA. 127+00
TO
STA.
140+50
C-110
PLAN AND PROFILE FORCEMAIN STA. 140+50
TO
STA.
155+00
C-111
PLAN AND PROFILE FORCEMAIN STA. 155+00
TO
STA.
169+50
C-112
PLAN AND PROFILE FORCEMAIN STA. 169+50
TO
STA.
184+00
C-113
PLAN AND PROFILE FORCEMAIN STA. 184+00
TO
STA.
198+50
C-114
PLAN AND PROFILE FORCEMAIN STA. 198+50
TO
STA.
213+50
C-115
PLAN AND PROFILE FORCEMAIN STA. 213+50
TO
STA.
227+50
C-116
PLAN AND PROFILE FORCEMAIN STA. 227+50
TO
STA.
242+00
5 Regional Circle
Suite A
Pinehurst, NC 28374
910.295.3159
NC Firm License # C-0459
mcgillassociates.com
Docu Signed by:
527402,1 IS
p SS/p°°°°`��,
SEAL o
o. 034999 0 -
;Q° ate;
5/25/2023
C-117
PLAN AND
PROFILE FORCEMAIN STA. 242+00
TO
STA.
256+50
C-118
PLAN AND
PROFILE FORCEMAIN STA. 256+50
TO
STA.
271+00
C-119
PLAN AND
PROFILE FORCEMAIN STA. 271+00
TO
STA.
284+50
C-120
PLAN AND
PROFILE FORCEMAIN STA. 284+50
TO
STA.
300+00
C-121
PLAN AND
PROFILE FORCEMAIN STA. 300+00
TO
STA.
314+50
C-122
PLAN AND
PROFILE FORCEMAIN STA. 314+50
TO
STA.
329+00
C-123
PLAN AND
PROFILE FORCEMAIN STA. 329+00
TO
STA.
343+50
C-124
PLAN AND
PROFILE FORCEMAIN STA. 343+50
TO
STA.
358+00
C-125
PLAN AND
PROFILE FORCEMAIN STA.358+00
TO
STA.
372+50
C-126
PLAN AND
PROFILE FORCEMAIN STA. 372+50
TO
STA.
387+00
C-127
PLAN AND PROFILE FORCEMAIN STA. 387+00 TO STA. 395+28.91
C-201
BUILDING FLOOR PLAN
C-202
BUILDING SECTION AND WALL SECTION
C-203
BUILDING ELEVATIONS
C-204
BUILDING SITE PLAN
C-501
MISCELLANEOUS DETAILS
C-502
MISCELLANEOUS DETAILS
C-503
MISCELLANEOUS DETAILS
C-504
MISCELLANEOUS DETAILS
C-505
MISCELLANEOUS DETAILS
C-506
TYPICAL SECTIONS
MAY 2023
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
LIMITS OF DISTURBANCE = 16.1 ACRES
S GENERAL SEWER NOTES
34 UPDATED MARCH, 2017
1. ALL CONSTRUCTION OUTSIDE RIGHTS -OF -WAY SHALL TAKE PLACE WITHIN THE PERMANENT AND TEMPORARY
ACCESS EASEMENTS SHOWN.
2. CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS TO EQUAL OR BETTER CONDITION THAN THE ORIGINAL SITE,
OR AS NOTED.
3. LOCATIONS OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE ONLY. EXACT LOCATIONS ARE TO BE VERIFIED
IN THE FIELD BY THE CONTRACTOR. AT LEAST THREE DAYS PRIOR TO CONSTRUCTION, CONTRACTOR MUST
NOTIFY EXISTING UTILITY OWNERS. CALL 811 BEFORE YOU DIG.
4. ALL WORK NEAR AND AROUND WATERWAYS MUST CONFORM TO THE RULES OF THE STATE OF NORTH
CAROLINA.
5. CONTRACTOR MUST PROVIDE EROSION CONTROL DEVICES TO CONTROL RUNOFF FROM THE CONSTRUCTION SITE.
CONTRACTOR WILL BE RESPONSIBLE FOR ANY FINES THAT MAY BE LEVIED DUE TO POLLUTION CREATED DURING
CONSTRUCTION.
6. CONTRACTOR SHALL FOLLOW ALL FEDERAL, STATE AND LOCAL HEALTH AND SAFETY REGULATIONS PERTAINING
TO CONSTRUCTION OPERATIONS.
7. SEWER FORCE MAINS AND WATER LINES SHALL HAVE 3'-0" MINIMUM COVER UNLESS OTHERWISE SHOWN ON
THE DRAWINGS.
8. WATER AND SEWER LINES SHALL HAVE A MINIMUM 10' HORIZONTAL SEPARATION OR A MINIMUM 18" VERTICAL
SEPARATION WITH THE WATER OVER SEWER, OR BOTH WATER AND SEWER LINES SHALL BE DUCTILE IRON PIPE
10' EITHER SIDE OF THE CROSSING.
9. SEWER AND STORM SEWER LINES SHALL HAVE A MINIMUM 24" SEPARATION. IF 24" SEPARATION IS NOT
OBTAINABLE, DUCTILE IRON PIPE SHALL BE USED FOR THE SEWER LINE OR A SUPPORTING MATERIAL SUCH AS
FLOWABLE FILL SHALL BE INSTALLED BETWEEN THE PIPES.
10. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION.
11. UNLESS OTHERWISE NOTED, ALL BURIED PIPE SHALL BE INSTALLED WITH PUSH -ON JOINTS AND EXPOSED PIPING
SHALL BE FLANGED JOINT.
12. LEGAL DESCRIPTIONS FOR PROPOSED EASEMENTS BY OTHERS.
13. SITE TOPOGRAPHIC AND BOUNDARY SURVEY PROVIDED BY SURVEYOR NOTED ON PLANS.
14. CONTRACTOR SHALL NOTIFY THE PROPER LOCAL AUTHORITIES 24 HOURS PRIOR TO ANY ROAD BEING CLOSED
FOR CONSTRUCTION, INCLUDING BUT NOT LIMITED TO LOCAL NEWSPAPER, RADIO STATION, FIRE DEPARTMENT,
COUNTY SHERIFF'S DEPARTMENT, AMBULANCE, AND COUNTY EMERGENCY AGENCY. ALL TRAFFIC CONTROL SHALL
CONFORM TO THE REQUIREMENTS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION.
15. CONTRACTOR SHALL NOTIFY THE ENGINEER AFTER EXISTING BURIED UTILITIES HAVE BEEN LOCATED AND 24
HOURS PRIOR TO CONSTRUCTION.
16. LOCATIONS SHOWN FOR SANITARY SEWER SERVICES ARE ASSUMED. COORDINATE LOCATIONS OF ALL PROPOSED
SEWER SERVICE CONNECTIONS WITH PROPERTY OWNER PRIOR TO CONSTRUCTION.
17. CONTRACTOR SHALL FIELD VERIFY ALL PROPOSED MANHOLE TOP ELEVATIONS AND EXISTING MANHOLE INVERTS
PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER OF ANY DISCREPANCIES. CONTRACTOR SHALL ADJUST ALL
PROPOSED SEWER STRUCTURES TO MATCH FINISHED PAVEMENT ELEVATIONS. COSTS OF RAISING STRUCTURES
SHALL BE CONSIDERED INCIDENTAL TO OTHER WORK ON THE PROJECT.
18. MANHOLES AND CASTINGS SHALL MEET THE REQUIREMENTS OF OWNER AS WELL AS THE PROJECT
SPECIFICATIONS.
19. 4" SANITARY SEWER SERVICE LINES SHALL BE INSTALLED AT 2.0% MINIMUM SLOPE AND SHALL BE DUCTILE
IRON IN PAVED AREAS.
20. ALL FENCE DAMAGED DURING CONSTRUCTION SHALL BE REPLACED WITH LIKE MATERIALS IN A WORKMANLIKE
MANNER AND IN ACCORDANCE WITH STANDARD FENCE CONSTRUCTION PRACTICES AT THE CONTRACTOR'S
EXPENSE.
21. CONTRACTOR SHALL FIELD LOCATE ALL BURIED TELEPHONE LINE IN CONFLICT WITH THE PROPOSED UTILITY LINE.
WHERE NECESSARY, EXISTING BURIED TELEPHONE LINE SHALL BE TEMPORARILY MOVED DURING CONSTRUCTION
OF THE PROPOSED UTILITY LINE AND RE-LAID AT NO ADDITIONAL COST TO THE OWNER.
22. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING ROADS DURING CONSTRUCTION AND
SHALL REPAIR ROADS PER REQUIREMENTS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION. NO
OPEN CUTS OF EXISTING ROADS SHALL BE ALLOWED EXCEPT WHERE INDICATED ON THE DRAWINGS OR WHERE
SPECIFIC PERMISSION IS GRANTED BY THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION. SAND OR A
SIMILAR MATERIAL APPROVED BY THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION SHALL BE PLACED
ON THE ROAD TO AID IN THE CLEAN UP AFTER CONSTRUCTION. A MINIMUM OF 2" OF SAND SHALL BE PLACED
ON THE ROAD PRIOR TO STOCKPILING SPOIL MATERIAL ON THE ROAD SURFACE TO FACILITATE CLEANUP.
23. CONTRACTOR SHALL MAINTAIN SEWAGE FLOW IN SEWER SYSTEM AT ALL TIMES AND SHALL PROVIDE BYPASS
PUMPING AND/OR PIPING AS REQUIRED. NO SANITARY SEWER OVERFLOWS ARE PERMITTED.
NCDOT PROJECT SPECIFIC NOTES:
1. ALL BLOW -OFF VALVES, VAULTS, MANHOLES AND OTHER
APPURTENANCES WITHIN THE NCDOT RIGHT OF WAY SHALL BE
LOCATED BEHIND THE DITCH AND AT THE RIGHT OF WAY LINE.
MANHOLES AND/OR VAULTS SHALL NOT BE PLACED IN THE DITCH
LINE, SIDE SLOPES OF DITCHES OR IN THE PAVEMENT.
2. FLOWABLE FILL SHALL BE PUMPED INTO THE ANNULAR VOID
BETWEEN CARRIER PIPES AND STEEL ENCASEMENT PIPES 24 INCHES
OR LARGER.
3. AT BORE AND JACK LOCATIONS, MINIMUM COVER IS MEASURED
FROM TOP OF CASING TO FINISHED GRADE.
4. MAINTAIN DRAINAGE IN PROJECT AREA - RE -GRADE EFFECTED
DITCH LINES TO MATCH OR EXCEED PRE -CONSTRUCTION
CONDITIONS.
5. THE BACKFILL AROUND AND UNDER PIPES OR OTHER UTILITY
INSTALLATIONS ON ALL OPEN CUT SECTIONS PARALLEL TO NCDOT
ROADWAYS WITHIN CONSTRUCTION LIMITS SHALL BE MADE OF
APPROVED MATERIAL, FREE FROM ROCKS IN 6-INCH LOOSE LAYERS,
OR OTHER APPROVED METHODS, AND SHALL BE COMPACTED TO AT
LEAST 95-PERCENT OF STANDARD DENSITY AS DETERMINED BY
AASHTO METHOD T-99.
Z2
EXISTING CONDITIONS LEGEND
,M
°PED
TELEPHONE PEDESTAL
ELEC
ELECTRIC PEDESTAL
,cnry
PED
CABLE TV PEDESTAL
iSIGN
SIGN
J CATV
UNDERGROUND CABLE TV SIGN
JUG FOC
UNDERGROUND FIBER OPTIC CABLE SIGN
JUG TCS
UNDERGROUND TELEPHONE CABLE SIGN
JUG GAS
UNDERGROUND GAS LINE SIGN
JUG ELEC
UNDERGROUND ELECTRIC LINE SIGN
LP
LIGHT POLE
• UP
UTILITY POLE
G
GUY WIRE ANCHOR
OTSP
TRAFFIC SIGNAL POLE
RXR
RAILROAD CROSSING SIGNAL
Q MH
MANHOLE
0 SSMH
SANITARY SEWER MANHOLE
Q SDMH
STORM DRAIN MANHOLE
0Comm
COMMUNICATION MANHOLE
ELMH
ELECTRICAL MANHOLE
Q J.B.
JUNCTION BOX
1' SPIGOT
SPIGOT/YARD HYDRANT
O C.O.
SEWER CLEAN -OUT
O E.SS
ELECTRIC SERVICE STUB -OUT
0 &SS
GAS SERVICE STUB -OUT
®C6
CATCH BASIN
'CI
CURB INLET
OwM
WATER METER
AFH
FIRE HYDRANT
°° wv
WATER VALVE
>a BLOw OFF VALV.
BLOW OFF VALVE
AGM
GAS METER
AG/V
GAS VALVE
>a Icv
IRRIGATION CONTROL VALVE
°° PIV
POST INDICATOR VALVE
® E.JUNC
ELECTRIC JUNCTION BOX OR OUTLET
Box
TRAFFIC SIGNAL BOX
x
x
x
0 0
0 0
0 0
0 0
0 0
0 0 0
4
CALCULATED POINT
GIPS
1/2" REBAR SET WITH CAP
0
CONCRETE MONUMENT
MCM-R/W
RIGHT-OF-WAY MONUMENT
®DOT
MON
D.O.T. CONTROL POINT
•RBF
REBAR FOUND
•RRSPIKE
RAILROAD SPIKE
OPK NIL
PK NAIL FOUND / SET
SPINDLE
SPINDLE FOUND / SET
OCPHUB
HUB & TACK SET
C ML GPS
CONTROL POINT NAIL SET / FOUND
CONTROL POINT/NAIL SET GPS
CP/MP
CONTROL POINT TEMPORARY MARK
*NOS METAL ROD
NATIONAL GEODETIC SURVEY METAL ROD
NGS CM
NATIONAL GEODETIC SURVEY CONCRETE MONUMENT
TEMPORARY CONTROL POINT SET
®
NETWORK TRIANGULATION POINT
A STAKE
STAKE FOUND
40
INTERSTATE HIGHWAY
66
U.S. HIGHWAY
FIFE
ELEVATION
FINISHED FLOOR ELEVATION
e Mw
MONITORING WELL
•PZ
PIEZOMETER
®
LANDFILL GAS MONITORING PROBE
•
SURFACE WATER SAMPLING LOCATION
0
LANDFILL GAS VENT
O
LANDFILL GAS COLLECTION WELLHEAD
POTABLE WATER WELL
OMB
MAILBOX OR PAPER BOX
❑PB
POSTAL DROP BOX
j SAT DISH
SATELLITE DISH
OYARD ORNAMENT
STATUE, BIRD BATHS, ETC.
TREES
0
SHRUBS / BUSHES
(H) HORIZONTAL
GROUND DISTANCE
(G) NC STATE
PLANE GRID DISTANCE
CULVERT
FENCE
SILT FENCE
GUARD RAIL
APPROXIMATE LOCATION OF
EXISTING SEWER LINES
APPROXIMATE LOCATION OF
EXISTING WATER LINES
APPROXIMATE LOCATION OF
EXISTING GAS LINES
TOP & TOE LINES
DITCH LINES
APPROXIMATE LOCATION OF
UNDERGROUND CABLE TV LINE
APPROXIMATE LOCATION OF
OVERHEAD CABLE TV LINE
APPROXIMATE LOCATION OF
UNDERGROUND FIBER OPTIC CABLE LINE
APPROXIMATE LOCATION OF
UNDERGROUND ELECTRIC LINE
APPROXIMATE LOCATION OF
OVERHEAD ELECTRIC LINE
APPROXIMATE LOCATION OF
UNDERGROUND TELEPHONE LINES
APPROXIMATE LOCATION OF
OVERHEAD TELEPHONE LINES
RIGHT-OF-WAY
TREELINE
SHRUBLINE
PROPERTY LINE NOT SURVEYED
00000000000000000000000 R O C K LI N E
- - - - - STREAM LINE
q
SURVEY INFORMATION PROVIDED BY-
@McG
A S S O C I A T E S
55 BROAD STREET ASHEVILLE, NC 28806 PH. (828) 252-0575
NC BOARD OF EXAMINERS CORPORATE LICENSE NO. C-0459
q
IPS
RBF
OTIPF
CTIPF
CMU
R/W
C
POB
CID
PB
DB
L
BLDG
CIP
CMP
CONC
CMU
CPP
DIP
E&T
FOC
GIP
O/H
RCP
U /G
VCP
PVC
FFE
PG
REF
DOT
NGS
NCSP
MTR BOX
CENTERLINE ROADS
CENTERLINE OTHER THAN ROADS
SWAMPLINE/WETLANDS
APPROXIMATE LOCATION OF
OVERHEAD UTILITY LINE
IRON PIN SET
REBAR FOUND
OPEN TOP IRON PIN FOUND
CRIMPED TOP IRON PIN FOUND
CONCRETE MASONRY UNIT
RIGHT OF WAY
CENTERLINE
CURVE (SEE CURVE TABLE)
POINT OF BEGINNING
CALCULATED POINT
PLAT BOOK
DEED BOOK
LINE (SEE LINE TABLE)
BUILDING
CAST IRON PIPE
CORRUGATED METAL PIPE
CONCRETE
CONCRETE MASONRY UNIT
CORRUGATED PLASTIC PIPE
DUCTILE IRON PIPE
ELECTRIC & TELEPHONE
FIBER OPTIC CABLE
GALVANIZED IRON PIPE
OVERHEAD
REINFORCED CONCRETE PIPE
UNDERGROUND
VITRIFIED CLAY PIPE
POLYVINYL CHLORIDE PIPE
FINISHED FLOOR ELEVATION
PAGE
REFERENCE
DEPARTMENT OF TRANSPORTATION
NATIONAL GEODETIC SURVEY
NORTH CAROLINA STATE PLANE
METER BOX
DocuSigned by:
CA
gEFORFy CHATHAM-RANDOLPH MEGASITE SHEET
5274Q9� LE j ooRO�i v G
NOT TO SCALE
5 Regional Circle ` =oo�oFEssio�9 ��,, o� SEWER SYSTEM EXTENSION
Suite A o • �' NOTES, ABBREVIATIONS AND LEGEND
SEAL < o
Pinehurst, NC 28374 Qo 034999 0� ` • a o TOWN OF SILER CITYOFFICE MANAGER DESIGNER
910.295.3159 = -v o.
NC Firm License # C-0459 %,G�,0 oo GINS --* C_j �; �9�' �'��
M I D. HONEYCUTT D. HONEYCUTT G=002
/����i HONEy��`�� ���GGING QP�� 2 5/9/23 DLH NCDOT COMMENTS PROJECT MANAGER REVIEWER DATE PROJECT # FUNDING #
C9 mcgillassociates.com 5/25Y�02%\\ CHATHAM COUNTY, NORTH CAROLINA
NO. DATE BY DESCRIPTION D. HONEYCUTT DECEMBER 2022 13.04039 N/A
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
REFER TO CURRENT NORTH CAROLINA DEPARTMENT OF ENVIRONMENT
AND NATURAL RESOURCES EROSION AND SEDIMENT CONTROL
PLANNING AND DESIGN MANUAL.
https: //deq.nc.gov/about/divisions/energy-mineral-and-land-resources
/erosion -and-sediment- control
5 Regional Circle
Suite A
C9Pinehurst, NC 28374
910.295.3159
NC Firm License # C-0459
mcgillassociates.com
-DocuSigned by:
-5274,§ �A 000M�o°�%;
�a ¢moo �9< o7
% SEAL a
Q oQ 034999
oti�
0.
0- CINE�y
0
....0*
4. HON
''�,iilllltt,,,,
3/14/2023
EC NORTH CAROLINA LAND QUALITY SECTION EROSION CONTROL NOTES
44 J FEBRUARY 2023
GENERAL: ALL EROSION CONTROL MEASURES ARE TO BE PERFORMED IN STRICT ACCORDANCE WITH REQUIREMENTS OF THE
NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY (NCDEQ), DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES
(DEMLR), LAND QUALITY SECTION. THE FOLLOWING CONSTRUCTION SEQUENCE SHALL BE COMPLIED WITH FOR ALL WORK.
1. EROSION AND SEDIMENT CONTROL (E&SC) PERMIT AND A CERTIFICATE OF COVERAGE (COC) MUST BE OBTAINED BEFORE ANY
LAND DISTURBING ACTIVITIES (INCLUDING TIMBERING AND DEMOLITION) OCCUR. CONTACT DEMLR RALEIGH REGIONAL OFFICE AT
LEAST 48 HOURS PRIOR TO COMMENCING THE LAND -DISTURBED ACTIVITY. THE CONTACT NUMBER IS (919) 791-4200.
2. PRIOR TO BEGINNING WORK ON THE PROJECT THE CONTRACTOR SHALL OBTAIN FROM THE OWNER A COPY OF THE "EROSION
AND SEDIMENT CONTROL APPROVAL" FROM THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY (NCDEQ).
DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES (DEMLR), DIVISION OF LAND QUALITY, OR THE LOCAL AUTHORIZED
PROGRAM. THE APPROVAL NOTICE MUST BE AVAILABLE ON -SITE DURING ALL GRADING AND CONSTRUCTION ACTIVITIES.
3. PER NPDES REQUIREMENTS, A RAIN GAUGE, SELF -INSPECTION RECORDS, PERMIT, CERTIFICATE OF COVERAGE, AND S&E PLAN
ARE REQUIRED TO BE MAINTAINED ON SITE AND ACCESSIBLE DURING INSPECTION. IT IS RECOMMENDED THAT THESE ITEMS BE
PLACED IN A PERMITS BOX AT THE BEGINNING OR ENTRANCE OF PROJECT.
4. SELF -INSPECTIONS FOR EROSION AND SEDIMENTATION CONTROL MEASURES ARE TO BE PERFORMED AT LEAST ONCE EVERY
SEVEN CALENDAR DAYS AND WITHIN 24 HOURS OF EVERY RAIN EVENT OF GREATER THAN 1 INCH. ANY NEEDED REPAIRS
SHALL BE MADE IMMEDIATELY TO MAINTAIN MEASURES AS DESIGNED. ALL ESC MEASURES SHALL BE MAINTAINED AS SPECIFIED
IN THE CONSTRUCTION DETAILS ON THIS PLAN. A RAIN GAUGE SHALL BE INSTALLED AT THE PROJECT SITE FOR MONITORING.
5. INSTALL ALL EROSION CONTROL MEASURES AS REQUIRED BY THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY,
DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES, LAND QUALITY SECTION.
NOTE: ALL UTILITY INSTALLATION WITHIN 25' OF A RIVER OR STREAM BANK SHALL BE INSTALLED PER STREAM PROTECTION
DURING EXCAVATION DETAIL. STABILIZATION SHALL BE COMPLETED DAILY IN AREAS WITHIN 100' OF STREAMS OR WETLANDS.
SILT FENCE IN THESE AREAS SHALL NOT BE INSTALLED CLOSER THAN 5' FROM CREEK BANK UNLESS FIELD CONDITIONS
PREVENT SUFFICIENT CLEARANCE. ALL SILT FENCES SHALL BE INSPECTED AND CLEANED AS NEEDED AFTER EACH RAIN.
6. CONSTRUCTION SHALL BE LIMITED TO 2000' OF CONTIGUOUS ROAD CORRIDOR UNTIL ALL CUTS, FILLS, AND DITCHES ARE
STABILIZED FOR THAT 2000' SECTION. UPON STABILIZATION OF THAT SECTION ANOTHER 2000' SECTION CAN BE CONSTRUCTED
AND STABILIZED.
7. PROCEED WITH GRADING, CLEARING AND GRUBBING. NOTE: NO OFF SITE DISPOSAL OF MATERIAL IS ALLOWED UNLESS THE
DISPOSAL SITE HAS AN APPROVED EROSION CONTROL PLAN.
8. SEED AND PLACE EROSION CONTROL MATTING ON ALL CUT AND FILL SLOPES THAT ARE NOT ROCK IMMEDIATELY UPON
COMPLETION OF SLOPE STABILIZATION.
9. ALL TEMPORARY STREAM AND CREEK CROSSINGS FOR EQUIPMENT DURING CONSTRUCTION SHALL BE MADE USING TEMPORARY
BRIDGES. NO STREAM BANK OR STREAM BED DISTURBANCE SHALL BE ALLOWED FOR EQUIPMENT CROSSINGS.
10. SEED AND MULCH DENUDED AREA WITHIN TIME FRAME SPECIFIED (SEE TABLES SEED AND SOIL AMENDMENTS SHALL BE PLACED
ON A PREPARED SEEDBED AT THE FOLLOWING RATES PER ACRE. STRAW MULCH SHALL BE TACKED WITH TACKING AGENT
APPLIED BY HYDROSEEDER.
11. MAINTAIN SOIL EROSION CONTROL MEASURES UNTIL PERMANENT GROUND COVER IS ESTABLISHED.
12. REQUEST FINAL APPROVAL BY THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY, DIVISION OF ENERGY, MINERAL,
AND LAND RESOURCES, LAND QUALITY SECTION.
13. REMOVE SOIL EROSION CONTROL MEASURES AND STABILIZE THESE AREAS.
14. WHEN THE PROJECT IS COMPLETE THE PERMITTEE SHALL CONTACT DEMLR TO CLOSE OUT THE EROSION AND SEDIMENT
CONTROL PLAN.
CUT/FILL SLOPES
SEEDING MIXTURE:
SPECIES RATE (lb/acre)
TALL FESCUE 100
SWITCHGRASS AND PARTRIDGE PEA MIX 30
KOBE LESPENDEZA 10
NURSE PLANTS:
BETWEEN MAY 1 AND AUG 15, ADD 101b/ac GERMAN MILLET
OR 15 Ib/ac SUDANGRASS. PRIOR TO MAY 1 OR AFTER AUG 15,
ADD 40 Ib/ac RYE (GRAIN). IT MAY BE BENEFICIAL TO PLANT THE
GRASSES IN LATE SUMMER AND OVERSEED THE LESPENDEZAS
IN MARCH.
SEEDING DATES:
BEST POSSIBLE
AUG 25 - SEPT 15 AUG 20 - OCT 25
FEB 15 - MAR 20 FEB 1 - APRIL 15
SOIL AMENDMENTS:
APPLY LIME AND FERTILIZER ACCORDING TO SOIL TEST, OR
APPLY 4000 Ib/ac GROUND AGRICULTURAL LIMESTONE AND
750 Ib/ac 10-10-10 FERTILIZER.
MULCH:
APPLY 4000 Ib/ac GRAIN STRAW OR EQUIVALENT COVER OF
ANOTHER SUITABLE MULCHING MATERIAL, ANCHOR MULCH BY
TACKING w/ ASPHALT, ROVING OR NETTING, NETTING IS THE
PREFERRED ANCHORING METHOD ON STEEP SLOPES.
MAINTENANCE:
MOW NO MORE THAN ONCE A YEAR, RE -FERTILIZE IN THE
SECOND YEAR UNLESS GROWTH IS FULLY ADEQUATE.
RE -SEED, RE -FERTILIZE, RE -MULCH DAMAGED AREAS IMMEDIATELY.
TEMPORARY SEEDI
SEEDING MIXTURE:
SPECIES RATE (lb/acre)
RYE (grain) 120
SEEDING DATES:
AUG 15 TO DEC 30
SOIL AMENDMENTS:
FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY
2000 Iyac GROUND AGRICULTURAL LIMESTONE AND
750 Ib ac 10-10-10 FERTILIZER.
MULCH:
APPLY 40001b/ac STRAW. ANCHOR STRAW BY TACKING
w/ ASPHALT, NETTING, OR A MULCH ANCHORING TOOL.
A DISK w/ BLADES SER NEARLY STRAIGHT CAN BE USED
AS A MULCH ANCHORING TOOL.
MAINTENANCE:
RE -FERTILIZE IF GROWTH IS NOT FULLY ADEQUATE, RE -SEED,
RE -FERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION
OR OTHER DAMAGE.
DITCH/OPEN AREA PERMANENT SEEDING SPECIFICATION
SEEDING MIXTURE:
SPECIES RATE (Ib/ac)
TALL FESCUE 250 (6 Ib/1000 sq ft)
NURSE PLANTS:
BETWEEN MAY 1 AND AU 15, ADD 10 Ib/ac GERMAN MILLET
OR 15 Ib/ac SUDANGRASS, PRIOR TO MAY 1 OR AFTER AUG 15,
ADD 40 Ib/ac RYE (GRAIN).
SOIL AMENDMENTS:
APPLY LIME AND FERTILIZE ACCORDING TO SOIL TEST, OR APPLY
4000 Ib/ac GROUND AGRICULTURAL LIMESTONE AND 750 Ib/ac
10-10-10 FERTILIZER.
MULCH:
USE CHANNEL LINING MATERIAL TO COVER THE BOTTOM OF DITCHES.
THE LINING SHOULD EXTEND ABOVE THE HIGHEST CALCULATED DEPTH
OF FLOW. ON CHANNEL SIDE SLOPES ABOVE THE HEIGHT, AND IN
DRAINAGES NOT REQUIRING TEMPORARY LININGS, APPLY 4000 Ib/ac
GRAIN STRAW AND ANCHOR STRAW BY STAPLING NETTING OVER THE TOP.
MULCH AND ANCHORING MATERIALS MUST NOT BE ALLOWED TO WASH
DOWN SLOPE WHERE THEY CAN CLOG DRAINAGE DEVICES.
MAINTENANCE:
INSPECT AND REPAIR MULCH FREQUENTLY. RE -FERTILIZE IN LATE WINTER
ACCORDING TO SOIL TESTS OR APPLY 150 Ib/ac 10-10-10 FERTILIZER
(3 Ib/1000 sq ft). MOW REGULARLY TO A HEIGHT OF 2" TO 4".
o
Q
GING QP� 1 03/14/23 DLHI NCDMLR COMMENTS
NO. DATE BY DESCRIPTION
PART III
SELF -INSPECTION, RECORDKEEPING AND REPORTING
SECTION A: SELF -INSPECTION
Self -inspections are required during normal business hours in accordance with the table
below. When adverse weather or site conditions would cause the safety of the inspection
personnel to be in jeopardy, the inspection may be delayed until the next business day on
which it is safe to perform the inspection. In addition, when a storm event of equal to or
greater than 1.0 inch occurs outside of normal business hours, the self -inspection shall be
performed upon the commencement of the next business day. Any time when inspections
were delayed shall be noted in the Inspection Record.
Frequency
Inspect
{during normal
Inspection records must include:
business hours)
(1) Rain gauge
Daily
Daily rainfall amounts.
maintained in
If no daily rain gauge observations are made during weekend or
good working
holiday periods, and no individual -day rainfall information is
order
available, record the cumulative rain measurement for those un-
attended days (and this will determine if a site inspection is
needed). Days on which no rainfall occurred shall be recorded as
"zero." The permittee may use another rain -monitoring device
approved by the Division.
(2) E&SC
At least once per
1. Identification of the measures inspected,
Measures
7 calendar days
2. Date and time of the inspection,
and within 24
3. Name of the person performing the inspection,
hours of a rain
4. Indication of whether the measures were operating
event > 1.0 inch in
properly,
24 hours
5. Description of maintenance needs for the measure,
6. Description, evidence, and date of corrective actions taken.
(3) Stormwater
At least once per
1. Identification of the discharge outfalls inspected,
discharge
7 calendar days
2. Date and time of the inspection,
outfalls (SDOs)
and within 24
3. Name of the person performing the inspection,
hours of a rain
4. Evidence of indicators of stormwater pollution such as oil
event > 1.0 inch in
sheen, floating or suspended solids or discoloration,
24 hours
5. Indication of visible sediment leaving the site,
6. Description, evidence, and date of corrective actions taken.
(4) Perimeter of
At least once per
If visible sedimentation is found outside site limits, then a record
site
7 calendar days
of the following shall be made:
and within 24
1. Actions taken to clean up or stabilize the sediment that has left
hours of a rain
the site limits,
event > 1.0 inch in
2. Description, evidence, and date of corrective actions taken, and
24 hours
3. An explanation as to the actions taken to control future
releases.
(5) Streams or
At least once per
If the stream or wetland has increased visible sedimentation or a
wetlands onsite
7 calendar days
stream has visible increased turbidity from the construction
or offsite
and within 24
activity, then a record of the following shall be made:
(where
hours of a rain
1. Description, evidence and date of corrective actions taken, and
accessible)
event > 1.0 inch in
2. Records of the required reports to the appropriate Division
24 hours
Regional Office per Part III, Section C, Item (2)(a) of this permit.
(6) Ground
After each phase
1. The phase of grading (installation of perimeter E&SC
stabilization
of grading
measures, clearing and grubbing, installation of storm
measures
drainage facilities, completion of all land -disturbing
activity, construction or redevelopment, permanent
ground cover).
2. Documentation that the required ground stabilization
measures have been provided within the required
timeframe or an assurance that they will be provided as
soon as possible.
NOTE: The rain inspection resets the required 7 calendar day inspection requirement.
PART III
SELF -INSPECTION, RECORDKEEPING AND REPORTING
SECTION B: RECORDKEEPING
1. E&SC Plan Documentation
The approved E&SC plan as well as any approved deviation shall be kept on the site. The
approved E&SC plan must be kept up-to-date throughout the coverage under this permit.
The following items pertaining to the E&SC plan shall be kept on site and available for
inspection at all times during normal business hours.
Item to Document
Documentation Requirements
(a) Each E&SC measure has been installed
Initial and date each E&SC measure on a copy
and does not significantly deviate from the
of the approved E&SC plan or complete, date
locations, dimensions and relative elevations
and sign an inspection report that lists each
shown on the approved E&SC plan.
E&SC measure shown on the approved E&SC
plan. This documentation is required upon the
initial installation of the E&SC measures or if
the E&SC measures are modified after initial
installation.
(b) A phase of grading has been completed.
Initial and date a copy of the approved E&SC
plan or complete, date and sign an inspection
report to indicate completion of the
construction phase.
(c) Ground cover is located and installed
Initial and date a copy of the approved E&SC
in accordance with the approved E&SC
plan or complete, date and sign an inspection
plan.
report to indicate compliance with approved
ground cover specifications.
(d) The maintenance and repair
Complete, date and sign an inspection report.
requirements for all E&SC measures
have been performed.
(e) Corrective actions have been taken
Initial and date a copy of the approved E&SC
to E&SC measures.
plan or complete, date and sign an inspection
report to indicate the completion of the
corrective action.
2. Additional Documentation to be Kept on Site
In addition to the E&SC plan documents above, the following items shall be kept on the
site and available for inspectors at all times during normal business hours, unless the
Division provides a site -specific exemption based on unique site conditions that make
this requirement not practical:
(a) This General Permit as well as the Certificate of Coverage, after it is received.
(b) Records of inspections made during the previous twelve months. The permittee shall
record the required observations on the Inspection Record Form provided by the
Division or a similar inspection form that includes all the required elements. Use of
electronically -available records in lieu of the required paper copies will be allowed if
shown to provide equal access and utility as the hard -copy records.
3. Documentation to be Retained for Three Years
All data used to complete the e-NOI and all inspection records shall be maintained for a period
of three years after project completion and made available upon request. [40 CFR 122.41]
PART II, SECTION G, ITEM (4)
DRAW DOWN OF SEDIMENT BASINS FOR MAINTENANCE OR CLOSE OUT
Sediment basins and traps that receive runoff from drainage areas of one acre or more shall use outlet structures that withdraw water from the surface when these devices need to be drawn down
for maintenance or close out unless this is infeasible. The circumstances in which it is not feasible to withdraw water from the surface shall be rare (for example, times with extended cold weather).
Non -surface withdrawals from sediment basins shall be allowed only when all of the following criteria have been met:
(a) The E&SC plan authority has been provided with documentation of the non -surface withdrawal and the specific time periods or conditions in which it will occur. The non -surface withdrawal
shall not commence until the E&SC plan authority has approved these items,
(b) The non -surface withdrawal has been reported as an anticipated bypass in accordance with Part III, Section C, Item (2)(c) and (d) of this permit,
(c) Dewatering discharges are treated with controls to minimize discharges of pollutants from Stormwater that is removed from the sediment basin. Examples of appropriate controls include
properly sited, designed and maintained dewatering tanks, weir tanks, and filtration systems,
(d) Vegetated, upland areas of the sites or a properly designed stone pad is used to the extent feasible at the outlet of the dewatering treatment devices described in Item (c) above,
(e) Velocity dissipation devices such as check dams, sediment traps, and riprap are provided at the discharge points of all dewatering devices, and
(f) Sediment removed from the dewatering treatment devices described in Item (c) above is disposed of in a manner that does not cause deposition of sediment into waters of the United States.
PART III
SELF -INSPECTION, RECORDKEEPING AND REPORTING
SECTION C: REPORTING
1. Occurrences that Must be Reported
Permittees shall report the following occurrences:
(a) Visible sediment deposition in a stream or wetland.
(b) Oil spills if:
• They are 25 gallons or more,
• They are less than 25 gallons but cannot be cleaned up within 24 hours,
• They cause sheen on surface waters (regardless of volume), or
■ They are within 100 feet of surface waters (regardless of volume).
(c) Releases of hazardous substances in excess of reportable quantities under Section 311
of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA
(Ref: 40 CFR 302.4) or G.S. 143-215.85.
(d) Anticipated bypasses and unanticipated bypasses.
(e) Noncompliance with the conditions of this permit that may endanger health or the
environment.
2. Reporting Timeframes and Other Requirements
After a permittee becomes aware of an occurrence that must be reported, he shall contact
the appropriate Division regional office within the timeframes and in accordance with the
other requirements listed below. Occurrences outside normal business hours may also be
reported to the Department's Environmental Emergency Center personnel at (800)
858-0368.
Occurrence
Reporting Timeframes (After Discovery) and Other Requirements
(a) Visible sediment
a Within 24 hours, an oral or electronic notification.
deposition in a
. Within 7 calendar days, a report that contains a description of the
stream or wetland
sediment and actions taken to address the cause of the deposition.
Division staff may waive the requirement for a written report on a
case -by -rase basis.
If the stream is named on the NC 303Ldl fist as impaired for sediment -
re iated causes, the permittee may be required to perform additional
monitoring, inspections or apply more stringent practices if staff
determine that additional requirements are needed to assure compliance
with the federal or state impaired -waters conditions.
(b) ail spills and
■ Within 24 hours, an oral or electronic notification. The notification
release of
shall include information about the date, time, nature, volume and
hazardous
location of the spill or release -
substances per Item
1(b)-(c) above
(c) Anticipated
. A report atieasr fen days before the date of the bypass, ifpossible-
bypasses[40 CFR
The report shall include an evaluation of the anticipated quality and
122.41(irl
effect of the bypass.
(d) Unanticipated
■ Within 24 hours, an oral or electronic notification.
bypasses [40 CFR
■ Within 7 calendar days, a report that includes an evaluation of the
122.411irl
quality and effect of the bypass.
(e) Noncompliance
■ Within 24 hours, an oral or electronic notification.
with the conditions
Within 7 calendar days, a report that contains a description of the
of this permit that
noncompliance, and its causes; the period of noncompliance,
may endanger
including exact dates and times, and if the noncompliance has not
health or the
been corrected, the anticipated time noncompliance is expected to
environment[40
continue; and steps taken or planned to reduce, eliminate, and
CFR 122.41(I)(7))
prevent reoccurrence of the noncompliance. 140 CFR 122,410)(6),
■ Division staff may waive the requirement for a written report on a
case -by -case basis.
K NCGO1 SELF -INSPECTION, RECORDKEEPING AND REPORTING EFFECTIVE: 04/01/191
GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH
Implementing the details and specifications on this plan sheet will result in the construction
activity being considered compliant with the Ground Stabilization and Materials Handling
sections of the NCG01 Construction General Permit (Sections E and F, respectively). The
permittee shall comply with the Erosion and Sediment Control plan approved by the
delegated authority having jurisdiction. All details and specifications shown on this sheet
may not apply depending on site conditions and the delegated authority having jurisdiction.
E:
Required Ground Stabilization
Timeframes
Stabilize within this
Site Area Description
many calendar
Timeframe variations
days after ceasing
land disturbance
(a) Perimeter dikes,
swales, ditches, and
7
None
perimeter slopes
(b) High Quality Water
7
None
(HQW) Zones
(c) Slopes steeper than
If slopes are 10' or less in length and are
3:1
7
not steeper than 2:1, 14 days are
allowed
-7 days for slopes greater than 50' in
length and with slopes steeper than 4:1
-7 days for perimeter dikes, swales,
(d) Slopes 3:1 to 4:1
14
ditches, perimeter slopes and HQW
Zones
-10 days for Falls Lake Watershed
-7 days for perimeter dikes, swales,
(e) Areas with slopes
ditches, perimeter slopes and HQW Zones
flatter than 4:1
14
-10 days for Falls Lake Watershed unless
there is zero slope
Note: After the permanent cessation of construction activities, any areas with temporary
ground stabilization shall be converted to permanent ground stabilization as soon as
practicable but in no case longer than 90 calendar days after the last land disturbing
activity. Temporary ground stabilization shall be maintained in a manner to render the
surface stable against accelerated erosion until permanent ground stabilization is achieved.
GROUND STABILIZATION SPECIFICATION
Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of the
techniques in the table below:
Temporary stabilization Permanent stabilization
■ Temporary grass seed covered with straw or
■ Permanent grass seed covered with straw or
other mulches and tackifiers
other mulches and tackifiers
■ Hydroseeding
■ Geotextile fabrics such as permanent soil
• Rolled erosion control products with or
reinforcement matting
without temporary grass seed
■ Hydroseeding
• Appropriately applied straw or other mulch
■ Shrubs or other permanent plantings covered
■ Plastic sheeting
with mulch
■ Uniform and evenly distributed ground cover
sufficient to restrain erosion
■ Structural methods such as concrete, asphalt or
retaining walls
■ Rolled erosion control products with grass seesLi
POLYACRYLAMIDES (PAMS) AND FLOCCULANTS
1. Select flocculants that are appropriate for the soils being exposed during
construction, selecting from the NC DWR List of Approved PAMS/Flocculants.
2. Apply flocculants at or before the inlets to Erosion and Sediment Control Measures.
3. Apply flocculants at the concentrations specified in the NC DWR List of Approved
PAMS/Flocculants and in accordance with the manufacturer's instructions.
4. Provide ponding area for containment of treated Stormwater before discharging
offsite.
5. Store flocculants in leak -proof containers that are kept under storm -resistant cover
or surrounded by secondary contain
EQUIPMENT AND VEHICLE MAINTENANCE
1. Maintain vehicles and equipment to prevent discharge of fluids.
2. Provide drip pans under any stored equipment.
3. Identify leaks and repair as soon as feasible, or remove leaking equipment from the
project.
4. Collect all spent fluids, store in separate containers and properly dispose as
hazardous waste (recycle when possible).
5. Remove leaking vehicles and construction equipment from service until the problem
has been corrected.
6. Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products
to a recycling or disposal center that handles these materials.
LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE
1. Never bury or burn waste. Place litter and debris in approved waste containers.
2. Provide a sufficient number and size of waste containers (e.g dumpster, trash
receptacle) on site to contain construction and domestic wastes.
3. Locate waste containers at least 50 feet away from storm drain inlets and surface
waters unless no other alternatives are reasonably available.
4. Locate waste containers on areas that do not receive substantial amounts of runoff
from upland areas and does not drain directly to a storm drain, stream or wetland.
5. Cover waste containers at the end of each workday and before storm events or
provide secondary containment. Repair or replace damaged waste containers.
6. Anchor all lightweight items in waste containers during times of high winds.
7. Empty waste containers as needed to prevent overflow. Clean up immediately if
containers overflow.
8. Dispose waste off -site at an approved disposal facility.
9. On business days, clean up and dispose of waste in designated waste containers.
PAINT AND OTHER LIQUID WASTE
1. Do not dump paint and other liquid waste into storm drains, streams or wetlands.
2. Locate paint washouts at least 50 feet away from storm drain inlets and surface
waters unless no other alternatives are reasonably available.
3. Contain liquid wastes in a controlled area.
4. Containment must be labeled, sized and placed appropriately for the needs of site.
5. Prevent the discharge of soaps, solvents, detergents and other liquid wastes from
construction sites.
PORTABLE TOILETS
1. Install portable toilets on level round at least 50 feet away from storm drains
P g Y
streams or wetlands unless there is no alternative reasonably available. If 50 foot
offset is not attainable, provide relocation of portable toilet behind silt fence or place
on a gravel pad and surround with sand bags.
2. Provide staking or anchoring of portable toilets during periods of high winds or in high
foot traffic areas.
3. Monitor portable toilets for leaking and properly dispose of any leaked material.
Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace
with properly operating unit.
EARTHEN STOCKPILE MANAGEMENT
1. Show stockpile locations on plans. Locate earthen -material stockpile areas at least
50 feet away from storm drain inlets, sediment basins, perimeter sediment controls
and surface waters unless it can be shown no other alternatives are reasonably
available.
2. Protect stockpile with silt fence installed along toe of slope with a minimum offset of
five feet from the toe of stockpile.
3. Provide stable stone access point when feasible.
4. Stabilize stockpile within the timeframes provided on this sheet and in accordance
with the approved plan and any additional requirements. Soil stabilization is defined
as vegetative, physical or chemical coverage techniques that will restrain accelerated
erosion on disturbed soils for temporary or permanent control needs.
ONSITE CONCRETE WASHOUT
STRUCTURE WITH LINER
IrgL Ah)
NN1C
LLt
16
k64
II�� ISAMI S10M0 N
i�L lmuel e,s.o N ILL tmo�q.� lolw'av�Ll�'ilL■ L M NLl[ v..mr
L M mL=IL MI■dr N■L'IIN. fWL yip �j,L p yra�p
S LWMLO MY M LlO MLIa If1L1LT fR? M t1■L11C
7s O M N■LII■R rMM,pdry� �jLL,,r M
MM amo■e MMII N■■IINC m m = t11LL N NLO R nmas
aan wwas 1LN ills R1L■ ays amoan wean mlclu[
pmow GR% 46FT� ADENE MAIE VASIa1T STRnCTIITE
CONCRETE WASHOUTS
1. Do not discharge concrete or cement slurry from the site.
2. Dispose of, or recycle settled, hardened concrete residue in accordance with local
and state solid waste regulations and at an approved facility.
3. Manage washout from mortar mixers in accordance with the above item and in
addition place the mixer and associated materials on impervious barrier and within
lot perimeter silt fence.
4. Install temporary concrete washouts per local requirements, where applicable. If an
alternate method or product is to be used, contact your approval authority for
review and approval. If local standard details are not available, use one of the two
types of temporary concrete washouts provided on this detail.
S. Do not use concrete washouts for dewatering or storing defective curb or sidewalk
sections. Stormwater accumulated within the washout may not be pumped into or
discharged to the storm drain system or receiving surface waters. Liquid waste must
be pumped out and removed from project.
6. Locate washouts at least 50 feet from storm drain inlets and surface waters unless it
can be shown that no other alternatives are reasonably available. At a minimum,
install protection of storm drain inlet(s) closest to the washout which could receive
spills or overflow.
7. Locate washouts in an easily accessible area, on level ground and install a stone
entrance pad in front of the washout. Additional controls may be required by the
approving authority.
8. Install at least one sign directing concrete trucks to the washout within the project
limits. Post signage on the washout itself to identify this location.
9. Remove leavings from the washout when at approximately 75% capacity to limit
overflow events. Replace the tarp, sand bags or other temporary structural
components when no longer functional. When utilizing alternative or proprietary
products, follow manufacturer's instructions.
10. At the completion of the concrete work, remove remaining leavings and dispose of
in an approved disposal facility. Fill pit, if applicable, and stabilize any disturbance
caused by removal of washout.
HERBICIDES, PESTICIDES AND RODENTICIDES
1. Store and apply herbicides, pesticides and rodenticides in accordance with label
restrictions.
2. Store herbicides, pesticides and rodenticides in their original containers with the
label, which lists directions for use, ingredients and first aid steps in case of
accidental poisoning.
3. Do not store herbicides, pesticides and rodenticides in areas where flooding is
possible or where they may spill or leak into wells, stormwater drains, ground water
or surface water. If a spill occurs, clean area immediately.
4. Do not stockpile these materials onsite.
HAZARDOUS AND TOXIC WASTE
1. Create designated hazardous waste collection areas on -site.
2. Place hazardous waste containers under cover or in secondary containment.
` 1`, NORTH CAROLINA 3. Do not store hazardous chemicals, drums or bagged materials directly on the ground.
ment structures. 4b ' Environmental Quality
NCGO1 GROUND STABILIZATION AND MATERIALS HANDLING
CHATHAM-RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
TOWN OF SILER CITY
CHATHAM COUNTY, NORTH CAROLINA
NOT TO SCALE
OFFICE MANAGER
D. HONEYCUTT
PROJECT MANAGER
D. HONEYCUTT
DESIGNER
D. HONEYCUTT
REVIEWER
EROSION CONTROL NOTES
DATE PROJECT # FUNDING #
DECEMBER 2022 13.04039 N/A
EFFECTIVE: 04/01 / 19
SHEET
G=003
M
0
v
0
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
Al PROPOSED LIFT STATION\
SEE SHEET C-204
N
aI \� ��♦ 1
0 1 I +50�I \
~ ♦♦' LO
10♦ fM s '�/ ♦♦
h �
PROPOSED DOUBLE BARREL 6'H x 11'W /
REINFORCED CONCRETE BOX CULVERT.
SEE SECTION AT BOX CULVERT, SEE /
SHEET C-506 /R.10\!NE /N0� CP
._0 •
/
0000
ssa h`°0000
OO /'
10 00
N
PLAN
� ./ 00
� N
A
°0000
\ \.0000
0001,
O
k
)SED GRAVEL DRIVE $
REPAIR PER DETAIL �, n
'
'
.000 ABILIO A CARDONA
/ PIN# 8732764295
/ RANDOLPH COUNTY
0000
/
0000
\/ r \ / \ ♦ /
g+ ' �\ , \ 0000
PROPOSED 18 C905—DR 21
u /
/ \
5 \ \ \ \ /� -/ . ♦ \ ♦ / PVC FORCE MAIN
00000
1 O / 3 MIN. COVER TYP.
-Exls I�1G\STREAM \ 6 -=� \\ /\ I ♦ / G\S \\NE
\ ;\ ) I ♦ / NAY
/\�\\\ \\\\\ \ _---�_ _ \ \k \\'✓/, I ♦ �' / ' /pNDO\ PROPOSED GRAVEL DRIVE o
\ \ \ \ \ \ - i '\/ ♦ ♦ / REPAIR PER DETAIL O
o
N
:, -
-
N
i
\ 584- -
O
o
L 583 — —
/ +
•�� �� \\ `\\�\ \`\--- �,\ \ \\ ` �`\ �r Il I ♦ ♦ / /' PROPOSED 16 1582-
--' `/ \ \ \ `\\��\ \`\�--�' ` �� �` \\ \ 1 WIDE GRAVEL
/ _ \ \ \ \ \ ,♦ , / '2 ♦ ACCESS DRIVE
5i \\ \ \\ �'��\\\ ---\ ` \TE�MP�R �Y �lL`T \\ rA o / ♦ xoo o ,�
\ \ \ \/-.-'� \ \ — \� `N 6F� RFDt\TA`I 1 I'� s� ♦ ♦ �`' k i , '' w
\ \ '
`\ -� \ \\ \ \ ,, i /� �♦ PROPOSED LIMITS
/� 1 1 ♦ ♦ OF DISTURBANCE
\ \ /
\ \� da,• //� //1/ J k 581
/ \ -
00.�•`\\`\`�
TEMPORARY RIPRAP
CH�CK DAM PER ♦ '2
,�� v v v v vvv v vvvvvvv� \, DET\A1L, TYPICAL
`v
� 0'
\
R
. 0w
585
580
575
570
565
555
550
545
PROPOSED
s'°ram
1 0
ls69 / R0`N
APPROXIMATE NCDOT RIGHT—OF—WAY
-Tts6�MPORARY INLET PER NCDOT "AS CONSTRUCTED PLANS"
/Row PROTECTION, TYPICAL
PROPOSED CONSTRUCTION Al
ENTRANCE
NOTE: LOCATIONS OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE ONLY.
EXACT LOCATIONS ARE TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR.
NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS FOLLOWS.
SEE EROSION CONTROL DETAILS FOR INSTALLATION AND MAINTENANCE REQUIREMENTS.
LOCATION LINING TYPE MINIMUM WATTLE SPACING
16+55 TO 26+60 NAG S75 MATTING OR EQUAL 50' O.C.
PROPOSED 50 LF 18" CMP ® 0.84
PROPO�ED 18" CLASS
250_DI FORCE_MAIN
zry
-' � >
0
ro U
11 +00
12+00
5 Regional Circle
Suite A
Pinehurst, NC 28374
910.295.3159
NC Firm License # C-0459
mcgillassociates.com
PVOPD DIP TO
TR�NSITION �
W
13+00 14+00 15+00 16+00
—DocuSigned by:
/.?, G
-5274o�0iq C 0 So,,, �
. o 0 of �otio 2 .
10
=o4,z- y� oy
Qy
V , C
= o SEAL _
,
O o034999 0
0 �� ;
�FocINE��°°GJ:'
00H
N9,�
3
5/9/23
DLH
NCDWI COMMENTS
4
GING QP�
1
03/14/23LBY
NCDMLR COMMENTS
iiiiii,,,\,
NO.
DATE
DESCRIPTION
5/25/2023
PROFILE
SCALE: HORIZ. 1 "= 50'
VERT. 1 "= 5'
EXISTING I GROUND
PROPOSED 18" C 05-DR 21
PVC FORCE MAIN
(3' MIN. COVER, YP.)
17+00 18+00 19+00 20+00
CHATHAM-RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
TOWN OF SILER CITY
CHATHAM COUNTY, NORTH CAROLINA
21 +00 22+00
50 0 25 50 100
GRAPHIC SCALE DIVISION VALUE = 50 FEET
OFFICE MANAGER DESIGNER
D. HONEYCUTT D. HONEYCUTT
PROJECT MANAGER REVIEWER
D. HONEYCUTT
23+00
585
575
570
565
560
555
550
545
24+00 24+50
PLAN AND PROFILE FORCEMAIN
STA. 10+00 TO STA. 24+50
DATE
DECEMBER 2022
PROJECT # FUNDING #
13.04039 N/A
SHEET
C=1 0 1
H
U
w
J
w
0
z
0
F_
z
0
co
z
w
X
w
w
w
w
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
IIe
CIS
PLAN
/
LO
+
cv
J
Q�r-585
TEMPORARY INLET
/ PROTECTION, TYPICAL O
/ o + / o TEMPORARY WATTLE,
+ TYPICAL
G\5 PROPOSED 18" C905-DR 21 O to/�
N � / O
/ / RP LPN GON PVC FORCE MAIN - I O
(3 MIN. COVER, TYP.)
• • —'—� ' � 0 O PROPOSED LIMITS
TEMPORARY RIPRAP CHECK o �r�� — L = �— —
�— __ _ _ __ ____ __ _ �•_..� ���— _ + OF DISTURBANCE
DAM PER DETAIL, TYPICAL _, _ __ __ _
—DL �I \ \\\a w= =.� \ STING
- D �— — — — I J I � � _- _ \ .�♦' � \ WETLAND AREA
g16 JCS PEA U.E _, ♦ —� o
5 h�k S.R.2 OAS \ �!♦� \ ^'`
k
O �� o_�L/-- �� `'a�h/ _ BROW— — —ROW— — — — _ROW— h 5 565 ``\ \�z ♦♦ O
O ' ` \ \�
c9 ROWS
w
ROW, `� ♦ \
k0 �/o 10
p �yo
e F,
\
TEMPORARY SILT Row\00
�� ♦ ���__ - Row FENCE, TYPICAL
APPROXIMATE NCDOT RIGHT-OF-WAY \RO
586 - �R°w� PER NCDOT "AS CONSTRUCTED PLANS" w�
� PROPOSED AIR/VACUUM RELIEF \ROWv S
VALVE (AT ACTUAL HIGH POINT) �VZ
R Q
NOTE: LOCATIONS OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE ONLY.
EXACT LOCATIONS ARE TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR.
PROFILE
NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS FOLLOWS.
SCALE: HORIZ. 1 "= 50'
SEE EROSION CONTROL DETAILS FOR INSTALLATION AND
MAINTENANCE REQUIREMENTS.
VERT. 1 "= 5'
LOCATION LINING TYPE
MINIMUM WATTLE SPACING
CENTERED
ON RCP
595
26+60 TO 35+00 NAG S75 MATTING OR EQUAL 30' O.C.
595
35+00 TO 42+75 NAG S75 MATTING OR EQUAL
100' O.C.
PROPOSED
AIR VACU
M RELIEF
590
590
585
----
------------
- I----------
��--
EXISTING GROU14D
580
OMEN=-
580
'��
A
II
�—
II
575
575
570
570
'��.
--�----
------
5659-1
565
0 z
------ '
'
'
,
7%q
----------
-----------
-�----------
-----
J
24"RCP
560
I
560
555
555
25+00 26+00
27+00 28+00 29+00
30+00 31 +00 32+00 33+00 34+00 35+00
36+00 37+00 38+00
39+00
5 Regional Circle
Suite A
Pinehurst, NC 28374
910.295.3159
NC Firm License # C-0459
mcgillassociates.com
DocuSigned by:
� �,�N'�'^+"R'���,
5274Q2\ �C��B51°° ooO�C /i
�_oo�oF� s�-4 o'er _
9<
= SEAL o =
- 0 034999 0 __
�� °o o°
L°oFN ��;� J
=, �p °° GINE °° c, '
/'1,,4 o°HONEy.``��\
5�z'��td�,���
eEFoRF
��`' �'o�
Q
y�, O �k,�
F ,�
Q'
�/� QP
DING
CHATHAM-RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
TOWN OF SILER CITY
50 0 25 50 100
PLAN AND PROFILE FORCEMAIN
TA. 24+50 T TA. 39+00
SHEET
C=1 02
GRAPHIC SCALE DIVISION VALUE = 50 FEET
OFFICE MANAGER
D. HONEYCUTT
DESIGNER
D. HONEYCUTT
1
03 14 23
/ /
DLH
NCDMLR COMMENTS
CHATHAM COUNTY, NORTH CAROLINA
PROJECT MANAGER
D. HONEYCUTT
REVIEWER
DATE
DECEMBER 2022
PROJECT #
13.04039
FUNDING #
N/A
NO.
DATE
BY
DESCRIPTION
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
IIe
\
Y �-
PLAN Zr
O O
U U
NO E: LOCATIONS OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE ONLY.
EXA T LOCATIONS ARE TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR. p
TEMPORARY INLET
UNRECORDED OWNER PROTECTION PER o ��
II�gTCH PIN# 8732757941 DETAIL, TYPICAL o n
LINE S7.A 39 RANDOLPH COUNTY R r
+00
ICI + R0`N-'
Ul
'a PROPOSED LIMITS o `O / 510�• �—y
69 OF DISTURBANCE +-
� ROW • �
/ ♦�� "N�-L--- —// BRA \CP
PROPOSED CONCRET +•
DRIVE REPAIR PER D AIL
I 40 ABILIO A CARDONA Op •'•• f= �••l
I 510 11 1 +�0
to PIN# 8732764295 •••_
RANDOLPH COUNTY O / • • • • - �j / oI\— — — — — _ _ /
11 I d- - 572 \� / � i
----- h�� - -
I o // __--573 510 PROPOSED GRAVEL DRIVE
I A- f -574 � ,- REPAIR PER DETAIL
1 TEMPORARY CHECK DAM,
TYPICAL o '
0 41+00 �/ / /--�Row/
PROPOSED 18" C905-DR 21
I 00 PVC FORCE MAIN
it i ko/Row 5 z 1,:Sso (3' MIN. COVER, TYP.)
c�2+013 i 580
5,5- /
o3 � -----� _575 __ /
_, _ _ ' �g �``,Cr`cj' PROPOSED AIR/VACUUM RELIEF Row
VALVE (AT ACTUAL HIGH POINT) �<
PROPOSED 18 PLUG � \�, .r/ \
VALVE W/VALVE BOX / w ,� gyp'' -74 ,Row'
APPROXIMATE COUNTY LINE PER
TEMPORARY DROP INLET NCDOT "AS CONSTRUCTED PLANS"
—573- PROTECTION PER
i I 18011 DETAIL, TYPICAL /Mop APPROXIMATE NCDOT RIGHf\--OF-WAY
PER NCDOT "AS CONSTRUCTED PLANS"
PROFILE NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS
FOLLOWS.
SCALE: HORIZ. 1 "= 50' SEE EROSION CONTROL DETAILS FOR INSTALLATION AND MAINTENANCE REQUIREMENTS.
VERT. 1 "= 5' LOCATION LINING TYPE MINIMUM WATTLE SPACING
595
595
50+10 TO 57+40 NAG S75 MATTING OR EQUAL 100' O.C.
590
590
585
585
PROPOSED
18 PLUG
PROPOSED
AIR/VACUUM
RELIEF
VALVE W
ALVE BOX
VALVE
AT ACTUAL
HIGH P
INT
EXISTING
GROUND
580
580
-
575
.----
---- -
--------
,,,
575
570
--- -----
-------
-
,
,,-
------------
------------
- -
570
565
18" C9
—PROPOSED
5-DR 21
565-
PVC FORCE
MAIN
3' MIN.
COVER T
560
560
555
555
40+00 41 +00 42+00
43+00 44+00
45+00 46+00
47+00 48+00 49+00 50+00
51 +00
52+00 53+00
53+50
5 Regional Circle
Suite A
Pinehurst, NC 28374
910.295.3159
NC Firm License # C-0459
mcgillassociates.com
DocuSigned by:
N'cARo,,,,,,
5274Q8�'16S13gC�000000 i
; oeoo ssi ti° o�=;
= SEAL *0=
- 0 034999 0 __
�� °o o°
L°oFN ��;�
'-,'O °°°�!NE°°yG,.'
��,,,�� �I H10N��`��
5/25/2023
EFORF y
�,� Goy
Q
y O k,�
��GGING QQ�
CHATHAM-RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
TOWN OF SILER CITYOFFICE
50 0 25 50 100
PLAN AND PROFILE FORCEMAIN
TA. 39+00 T TA. 53+50
SHEET
C=1 03
GRAPHIC SCALE DIVISION VALUE = 50 FEET
MANAGER
D. HONEYCUTT
DESIGNER
D. HONEYCUTT
1
03/14/23
DLH
NCDMLR COMMENTS
CHATHAM COUNTY, NORTH CAROLINA
PROJECT MANAGER
ID. HONEYCUTT
REVIEWER
DATE
DECEMBER 2022
PROJECT #
13.04039
FUNDING #
N/A
NO.
DATE
BY
DESCRIPTION
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
Ie
PLAN
NOTE: LOCATIONS OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE ONLY.
EXACT LOCATIONS ARE TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR.
PROPOSED 18" C905-DR 21
PVC FORCE MAIN
N
(3' MIN. COVER, TYP.)
TEMPORARY CHECK DAM
WILLIAM L. SMITH, ETAL
PER DETAIL, TYPICAL
PIN# 8732-85-6839.000
PROPOSED GRAVEL DRIVE
LYDIA S. SNIPES, ETAL
PARCEL 65294
REPAIR PER DETAIL
PIN # 8742-00--06-2476
PARCEL 12560
PROPOSED LIMITS
TEMPORARY PIPE INLET TEMPORARY
INLET P OPOSED
GRAVEL DRIVE
OF DISTURBANCE
PROTECTION,
TYPICAL
0 PROTECTION, TYPICAL
REPAIR PER DETAIL
0
0
0
0
+
0
0
0
0 0 0 0 0
0 0 0 0 0 0
0
0
+
O
L0
LC)
LO
Ln
LO
r-
L()
0+p
L(�
Gn 0+ + N + �
LO co cfl 0 n EXISTING STREAM
+
0
O
3
— — RQ -- --
RGW— -- one p
--
3 3 3 3 3 3 3 3 3
— RO — — — ROW— — — —ROW— — — —ROW----- 0 — — — —ROW— —
— —ROW—
`� a ROW— — 3
3 — 3 ROW—
00
— 3 CO
Q
_---------
_
FOWN
_
_
__
_ - _-- __ _ 580 _ _
T� �
Z
----- --- — 56 -- DL-----0 r �560 _ - -
DL----- DE _ = 6C — -- Dom= -- DL--- - - -- __- _-- DL = - - - - - I
■ �i��al�� i� !•��� - �Z-- 6 �}t ----�
- ___=rL\-7-.
-- -- ----- ----- ----- ----- DL----- B6i�----- - - �_ -
�y�'_ ' / DL _ - - - - - - - - - -
I
i---W
- _ -
_ _ v-
- 575- - - - _— DL _ - _ ==-k _UC = — _ DL----- D --_ -_ �yJ
tl� I�I�_� �I� il��■J� L -ice
—565—
_-------
GRAVEL
�\��- - I i
------� � GRAVEL
\ / / < GRA�Et�� i� __�_--5-----��/ii -- _-- ��-
- GR�V€L---�---
---_ J
/�/ ,�/ ' /���/ i'9
s s �s s �3 , Cs AMHsl
I I
I I
I I
I I
I I
i r
i j
TEMPORARY
SILT
FENCE, TYPICAL
I I
I
I
I I
/
I I
I I
i j
/
—Mod —
—mod—
— —Mod—
- — OW-—
-------------------------------
-------
--ROW--
— — —ROW—
— — —ROW—
—
-- —ROW—
— — ROW— — —- - — -
`
— —ROW—
\
APPROXIMATE—
NCDOT RIGHT-OF-WAY
L
PER NCDOT "AS CONSTRUCTED PLANS"
�o�
.,
595
595
PROFILE NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS FOLLOWS.
SCALE: HORIZ. 1 "= 50' SEE EROSION CONTROL DETAILS FOR INSTALLATION AND MAINTENANCE
REQUIREMENTS.
VERT. 1 "= 5' LOCATION LINING TYPE
MINIMUM WATTLE
SPACING
57+40 TO 60+20 NAG S75 MATTING OR EQUAL
25' O.C.
590
590
63+00 TO 71+00 NAG S75 MATTING OR EQUAL
50' O.C.
585
585
580
580
575
EXISTING
GROUND
570
570
A,—
-
"RCP
---
------------
----
----------
_-,
``
-i65------
'
�
-
565
--
_ -
V
II II
---'''
52"RCP
II y
---
-----------
%'...�-
/
—
PP
iiy
II 4
0
560
\i
PROPOSE
18" C90
-DR 21
555
PVC FORE
MAIN
LU
z v
555
' MIN.
R, TY
Z
(V
550
550
54+00
55+00
56+00
57+00
58+00
59+00 60+00 61 +00 62+00 63+00 64+00
65+00 66+00 67+00
68+00
DocuSigned by:
IR/'/,,,,
C°S°rS1
,�,�gEFORFY
CHATHAM-RANDOLPH MEGASITE
50 0
25 50 100
SHEET
527 B2 B9 C�O° '/
O
Goy
5 Regional Circle
/'
o°og�,�'�=;
SEWER SYSTEM EXTENSION
PLAN AND PROFILE
FORCEMAIN
,'Ord
Suite A
Pinehurst, NC 28374
°Q� 9< �� '
- SEAL o =
Q o 034999 0%
��`'
V , C
, o
TOWN OF SILER CITY
GRAPHIC SCALE
DIVISION VALUE = 50 FEET
STA. 53+50 TO
G
STA. 6�+00
C=1
OFFICE MANAGER
DESIGNER
910.295.3159
=�L'�FN ��;°'J;'
'-, /O °°°G!NE°000
y O k,�
D. HONEYCUTT
D. HONEYCUTT
NC Firm License # C-0459
C) �'
��/,�� °HON�����
F ��'
��GGING
PROJECT MANAGER
REVIEWER
DATE
PROJECT#
FUNDING#
mcgillassociates.com
5����rt�`�
QQ�
1
03/14/23
DLH
NCDMLR COMMENTS
CHATHAM COUNTY, NORTH CAROLINA
NO.
DATE
BY
DESCRIPTION
D. HONEYCUTT
DECEMBER 2022
13.04039
N/A
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
Ile
PLAN
NOTE: LOCATI NS OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE ONLY.
I
EXACT LOCATI S ARE TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR.
\ROPOSED
I
N
ASPHALT DRIVE
REPAIR PER DETAIL
PROPOSED 18" PLUG VALVE
TIMS FARM & FORESTRY, LLC
W/VALVE BOX
I
PIN# 8732-95-7674.000
G5 INVESTMENTS, LLC G5 INVESTMENTS, LLC
G5 INVESTMENTS, LLC
PROPOSED LIMITS
OF DISTURBANCE
PARCEL 67263
TEMPORARY INLET
PROTECTION, TYPICAL
PIN # 8742-05-9654. 0
PARCEL63971
PIN # 8742-04-5997.000
PARCEL i2s5i
0
PIN# 874 997.000
PARCEELL125s2
0
0
0
+
rn
0
0 0
0
+ +
0
r r
0 0 0
0 0 0
+ + +
N NOL0
r
0 0 0
0
0 0 0 0
+ + + +
0 0
I
r `
0 0
0 0
+ +
0)0
r 0
0`
+
EXISTING STREAM -
00
0
0
+
N
00
00
CO -
-R
—
—
D
_ — — — — — — — —
- 3
5.85E���
—
— — — — — — — — — — — — —
— — —
�_ _
ISM °�
— — — —
_ —
— — — — — — — — — — — — — — —
moo- 3 -T�.,�
--- ---- __— = ----
EEE E ����� ���_ M/MM=IN
-------- — — — — —__ __
_ — —_ _
— — — L-- ——-�L
_
— — — — — — — — — — — — — — — — — — — — — — — — — — — —
- - - - - - ROW- - -
_M--_=_ — / _--- — s — --_ — -- — —-
-__DLW
\_ L u5� --- --- ------
ASPHALT
-ROW- - - -ROW- - - -ROW- - -
_ ---_ ---SL- ---/T
— _——BL =6L�— --- —BL57
S5—_ I I
`
IIIIWWII
—
ROW o - - R
�
O
In
+
00
Q
W
s
s\
s8A
—5 ii g0h i 582 5$` h
11
11
PROPOSED AIR/VACUUM RELIEF
VALVE (AT ACTUAL HIGH POINT) ;;'
, ,
PROPOSED 18" C905—DR 21 %�
PVC FORCE MAIN %i�'
(3 MIN. COVER, TYP.) ;
-----------------
h�9 0�$ 5 h16i it
I I
I 1
'I'I
TEMPORARY DROP INLET_j
PROTECTION PER DETAIL, TYPICAL
II
I I
I I
I I
I I
TEMPORARY SILT FENCE, „
TYPICAL ;U
--------------
41"
cQQ
G
-------------
ROW- -
-----------------------------------------------
- - ROW- - -
- ROW- - - - ROW-
- - - ROW-
- - - ROW- - - - ROW- - - -
----- ---------
ROW- - - - ROWW�-- - -ROW- - \\ -ROW-
- - -ROW -
-ROW- -
- -ROW--
APPROXIMATE NCDOT RIGHT—OF—WAY
PER NCDOT "AS CONSTRUCTED
LANS"
600
1
1
600
PROFILE NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS FOLLOWS.
SEE EROSION CONTROL DETAILS FOR INSTALLATION
AND MAINTENANCE REQUIREMENTS.
SCALE: HORIZ. 1 "= 50'
VERT. 1 "= 5' LOCATION LINING TYPE MINIMUM WATTLE SPACING
74+40 TO 75+00 NAG SC250 MATTING OR EQUAL 20' O.C.
595
595
77+00 TO 81+50 NAG S75 MATTING OR EQUAL
30' O.C.
AIR V CUUM RELIEF
[—PROPOSED
AT ACTUAL HIGH P INT
VALVE
590
EXISTING
GROUND
590
-----
585
585
�
---
__
----
--
-------
PROPO
W VALVE
ED 18 PUG
BOX
VALVE
---------
----
-
580
DSO
--------------------
-
0575
- ----
575
PROPOSED 18" C9
5—DR 21
PVC FORCE
MAIN
570
570
i 5"RCF
It I
`
I
32
RCP
565
565
560
560
Ae
w
555
p z
555
LU
J
69+00 70+00 71 +00
72+00 73+00 74+00
75+00 76+00 77+00 78+00
79+00 80+00
81 +00
82+00 82+50
McgiL°oFN
5 Regional Circle
Suite A
Pinehurst, NC 28374
910.295.3159
NC Firm License # C-0459
mcgillassociates.com
DocuSigned by:
6,N''^+"R'���,
5274Q2\�C��B51°° ooO6C
;�_oo�oF�s�o�,°o'er=;
= °Q� 9< �� =
= SEAL o =
- 0 034999 0 __
�� °o o°
��;� J;'
'-, /O °°°SINE°-o* C) �'
,,�/� °HON�����
s/��y�2oP��
eEFoRF
��`' �'o
V , C
Q
y�, O �k,�
F
��GGING QQ�
CHATHAM-RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
TOWN OF SILER CITYOFFICE
50 0 25 50 � oo
PLAN AND PROFILE FORCEMAIN
TA. 68+00 T TA. 82+50
SHEET
C=1 05
GRAPHIC SCALE DIVISION VALUE = 50 FEET
MANAGER
D. HONEYCUTT
DESIGNER
D. HONEYCUTT
1
03/14/23
DLH
NCDMLR COMMENTS
CHATHAM COUNTY, NORTH CAROLINA
PROJECT MANAGER
D. HONEYCUTT
REVIEWER
DATE
DECEMBER 2022
PROJECT#
13.04039
FUNDING#
N/A
NO.
DATE
BY
DESCRIPTION
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
\
\
—PROPOSED CONCRET
DRIVE REPAIR PER DE AIL
RICHARD DEVANE KIRKMAN & DIANE \
PIN # 8742-04-9960.000
\
—
I
I
I
KATHIE L. RUSSELL TRUSTEE
PIN # 8742-24-5978.000
PROPOSED 387 LF 20" DR 9 PARCEL 12553 I
I PROPOSED 18" C905—DR 21
HDPE FORCE MAIN INSTALLED
G INVESTMENTS, LC I PVC FORCE MAIN
BY DIRECTIONAL DRILL PIN 8742-25-0677.00 (3' MIN. COVER, TYP.)
PA EL78171 ` KATHIE L. RUSSELL TRUSTEE
G5 INVESTMENTS, LLC DENNIS LANE ANDREWS & DONNA I PIN# 8742-24-5978.000
8742-2
PROPOSED BEGIN PIN# 8742-05-9654.000 PINPARCEL12575 000 TEMPORARY DROP PARCEL 12553
PARCEL63971 PROPOSED END
DIRECTIONAL DRILL DIRECTIONAL DRILL INLET PROTECTION
Al PER DETAIL, TYPICAL
0
0
0
0
+
EXISTING
+
+
+
(
STREAM
O
0000
0000
00
+
cV
00
W—
— — ROW—
— ROW— —
— —ROW-
—
—ROW
--
WIRE FENyE
----
—-- - -
57
--3--� --- ----
------
---_---—--—--
✓__
`
Uj
— : T; _:� _
``::' 565 ^�' %;
J
_
_
ON RE
\�----------------�
5
h
TEMPORARY CHECK
DAM, TYPICAL
,1
595
590
585
580
575
570
565
560
555
0 0 00 00 0 0 00
o+o 0 +`JIt
I n L0 G7
00 00 rn °) rn rn rn
O
°)
-�+�-- --- ♦~ --��—�/ -M— -- -- �� ---� - - I '---- - --—O
—ROW——ROW—ROW —ROW— —ROW——ROW—
MMM
+
----- -- -- \ --\
--\ \— \
M-----M �- — M ——M—�---t MMMUM �__--------M-----M----�- Qi
w2k
FyNA
l Q
DL
— /
--_�-/ -�� � - - •575 ��/ I _ - _,--- - ,,--����y�p sa �>•�f�_ _�Ai�� MAN0 JrM M
mirwD — — _ — — —M — / LLI
GRAVEL a
---- ^ Z
TEMPORARY SILT
FENCE, TYPICAL
PROPOSED
TEMPORARY PIPE+CONSTRUCTION
INLET PROTECTION PER ,� +;1 ENTRANCE
DETAIL, TYPICAL
-Row— - APPROXIMATE NCDOT RIGHT—OF—WAY F-110W
— --ROw—
PER NCDOT "AS CONSTRUCTED PLANT'
I I,
— — ROW — — ROW— — — —ROW— — J
83+00
mcg
5 R�
2
0
Q
cs o �
15
PROPOSED ASPHALT DRIVE
PROPOSED GRAVEL [RIVE
REPAIR PER DETAIL I REPAIR PER DETAIL
-------------------------- TE: LOCATIONS OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE ONLY.
CHATHAM COUNTY EXACT LOCATIONS ARE TO BE VERIFI IN THE FIELD BY THE CONTRACTOR.
W— w I W-
---- ----
GIS PROPERTY LINE —W
IN.
84+00
5 Regional Circle
Suite A
Pinehurst, NC 28374
910.295.3159
NC Firm License # C-0459
mcgillassociates.com
I"Ir
85+00
—DocuSigned by: 01111
1.
—52744�(:S
g SEAL o =
a o 034999 0�
16
i�Z�G I N E�
HONE
/2'1 Y202A \\ 5
NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS FOLLOWS. PROFILE
SEE EROSION CONTROL DETAILS FOR INSTALLATION AND MAINTENANCE REQUIREMENTS. — SCALE: HORIZ. 1 "= 50'
LOCATION LINING TYPE MINIMUM WATTLE SPACING VERT. 1 "= 5'
88+50 TO 95+00 NAG S75 MATTING OR EQUAL 30' O.C.
95+50 TO 100+50 NAG S75 MATTING OR EQUAL 30' O.C.
EXISTING GROUND
PROPOSE LDR 9 HDPE FORCE
.LED BY DIR CTIONAL RILL
86+00 87+00
%\ BEFORFy0
C
Q
GING QQ� 1 03/14/23 DLH
NO. DATE BY
z
PROPOSED 18" C905—DR 21
PVC FORCE MAIN
88+00 89+00 90+00 91 +00 92+00 93+00
CHATHAM-RAN DOLPH MEGASITE
SEWER SYSTEM EXTENSION
TOWN OF SILER CITY
NCDMLR COMMENTS CHATHAM COUNTY, NORTH CAROLINA
DESCRIPTION
—ROW-
- -- — --
595 1 605
595
590
575 f 585
570 1580
PROPOS D 18- C90 —DR 21
PVC FOR MAIN
565 1 575
560 1 570
555 1 565
94+00 95+00
50 0 25 50 100
GRAPHIC SCALE DIVISION VALUE = 50 FEET
OFFICE MANAGER DESIGNER
D. HONEYCUTT D. HONEYCUTT
PROJECT MANAGER REVIEWER
D. HONEYCUTT
96+00
605
59
585
580
575
570
565
97+00
PLAN AND PROFILE FORCEMAIN
STA. 82+50 TO STA. 97+00
DATE PROJECT # FUNDING #
DECEMBER 2022 13.04039 N/A
SHEET
C=1 06
Q
z_
J
O
D_
Q
U
2
F
O
z
z
D
O
U
Q
Q
U
U
w
J
U)
w
O
z
O
z
O
co
z
w
x
w
w
U)
w
w
U)
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
I
M
PLAN
\
\
`
-''
TEMPORARY CHECK
`,
TEMPORARY PIP , INLET
DAM, TYPICAL
PROTECTION, TYPt AL
_M— PROPOSED 18" C905—DR 21
__,PVC FORCE MAIN
-' (3' MIN. COVER, TYP.)
�M' I
KATHIE L. RUSSELL TRUSTEE
_ _
PIN # 8742-24-5978.000
PARCEL 12553
TEMPORARY DROP
N,O
INLET PROTECTION
—Row' _ _ _ -M'
/ WI/AM L. SMITH, ETAL
PROPOSED LIMITS
PER DETAIL
gOA�
°�—
OF DISTURBANCE
i _--�M ytZLL1AMs
1IE
M PIN # 8742-43-0071.000
o �R
O O i�
,'M
O _ O
'M' O_ O
O O PARCEL 67033 O O
O
O O
O
O + O
O O O
LROW—
O O
00
rn-�R�_-� — O
O O O o
�--
+
°W �' '-M_6 PVC �-''
�M°�—ROW—
--
p�j — —ROW —
_
— — ROW— — — — ROW— — ,R w-
— — — — ——
— —ROW— — — —ROW— — — ROW— — — —ROW— — ROW
— —ROW— — — RO —
L�
+
---------
\ --�-�
- --� _ �M--\�--- 1-- �-
\--- \---- �— _------615- --_ --_
-
_
----�`-------------_
— —
- - -
DL- -- DL _ - DL--- ��f����
- - - - ----- ----- --- - -
DL---------DC= z�---- ----- -- ----- -- -
� � -. ������
RA
- - - - - - - - - - DL---
--- ----- --- DL-- - - - - - - - - - __- - S t t s E f
-----
—''-------
----- D =-_ _ - --
�
` — �-r- ��� ��w�rii�������
——
----------------- -- _-
D
_��-��-ii��
---
J_� ����'
6 MB \— _—,---------------
i`\\\ p5 0 zJ GRAVEL \ ---
---- --------------------------
------------------- ---- ��
- -
w
6�
_Z
boll
\
- ---
_600—-------
_
0— _—
i
PROPOSED GRAVEL DRIVE
REPAIR PER DETAIL
NOTE: LOCATIONS OF EXISTING
UTILITIES AS SHOWN ARE APPROXIMATE ONLY.
APPROXIMATE NCDOT RIGHT—OF—WAY EXACT LOCATIONS ARE TO BE
VERIFIED IN THE FIELD BY THE CONTRACTOR. ��;'/
PER NCDOT "AS CONSTRUCTED PLANS"
—ROW——
—ROW— — — —
—ROW— — — —ROW— — — —ROW—
ROW
— — — ——
—ROW— ROW—
ROW
ROW
�__�-
ROW_ --
— — ROW— —
—--------
— — ROW— ----ROW—
—--—--—--—--—
----ROW— ----ROW— —
----------—---------—----
— _ - -
—----—-------- _--
630
630
PROFILE
SCALE: HORIZ. 1 "= 50'
VERT. 1 "= 5'
625
625
620
620
615
615
EXISTING
GROUND
610
------------
---
i---------_
OEM
605
____
Pool
MIT
11jjMMMEwM=j=24-RCP
600
-''
-
600
-
6
WL
--''
18 RCP
PROPOS
D 18" C9
5—DR 21
• w
PVC FO
CE MAIN
— z
'S35
w
595
z
OQ
aI
LU
a
•w
590
— Z
U
590
oa
�
Ld
101, J
585
585
98+00 99+00 100+00 101 +00
102+00
103+00 104+00 105+00 106+00 107+00 108+00
109+00
110+00 111 +00 111 +50
DocuSigned by:
E\L�,R''
5214, A 0000° O 'i
�,�+� 6EFORF y0
CHATHAM-RANDOLPH MEGASITE
50 25 50°°
SHEET
5 Regional Circle
o°o�s'o�,°�'�';
o
SEWER SYSTEM EXTENSION
PLAN AND PROFILE FORCEMAIN
Suite A
;�
= °Q� 9< �� =
= SEAL o =
��`'
V , C
GRAPHIC SCALE DIVISION VALUE =
50 FEET
TA. 97+00 T TA. 111+50
inehurst, NC 28374
PC=1
- 0 034999 0 __
°o
Q
TOWN OF SILER CITYOFFICE
07
MANAGER
DESIGNER
M C9 1L°oFN
910.295.3159
NC Firm License # C-0459
o°
��
��;� J;'
'-,,�0 °°°�!NE°°°yG,.'
y O k,�
`F
D. HONEYCUTT
D. HONEYCUTT
mcgillassociates.com
'111,4 �� HONE�,.�`
O�GGING PQ'
e
CHATHAM COUNTY, NORTH CARO L I NA
PROJECT MANAGER
REVIEWER
DATE
PROJECT #
FUNDING
#
NO.
DATE
BY
DESCRIPTION
5/25/2023
D. HONEYCUTT
DECEMBER 2022
13.04039
N/A
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
Ile
M--
BORE AND JACK NOTES:
_M_ '-
---M—_ �--�_
PLAN
1. BOTTOM OF BORE PIT SHALL BE MINIMUM 1' H. : 1' V. THEORETICAL
SLOPE FROM EDGE OF PAVEMENT OR ACTIVE SHORING MUST BE USED.
_
2. SPOILS PILE SHALL BE PLACED ADJACENT TO BORE PIT WHERE ROOM EXISTS
EXISTS WITHIN ROAD RIGHT—OF—WAY OR SEWER EASEMENT. SILT
FENCE SHALL BE INSTALLED AND MAINTAINED ON THE DOWNHILL SIDE
OF THE SPOIL BORE PIT AND SPOIL PILE. CONTRACTOR SHALL PLACE
SPOILS IN DUMP TRUCK OR STORE IN OTHER LOCATION WITHIN
DISTURBED AREA IF ADEQUATE SPACE IS NOT AVAILABLE.
3. CONTRACTOR SHALL NOTIFY ENGINEER IF ROCK OR OTHER UTILITIES
ARE FOUND WITHIN THE BORE AREA PRIOR TO BEGINNING BORE AND
0I
Al
I
I
I I
,I -----
I
I PROPOSED 400 LF
I MAIN INSTALLED
i I
M--
M—__M--__ — Row _-�
-M _ _ _ _ PROPOSED 18 UG VALVE
20" DR 9 HDPE FORCE—M---_—Rower _ � _VALVE BOX
BY DIRECTIONAL DRILL TEMPORARY RIPRAP
CHECK DAM,
Mo _LPICAL---M--_
JACK. WHERE WHERE CONDITIONS DO NOT ALLOW BORE, ENGINEER MAY I
COORDINATE WITH NCDOT TO REQUEST OPEN CUT OF ROADWAY. I o
I cn a
0
PROPOSED 65 LF 30"0 x 0.375" I o
-
WALL THICKNESS STEEL ENCASEMENT I a
PIPE, BORED AND JACKED WITH 18" %
WILLIAM L. SMITH, ETAL 0 CLASS 250 DIP CARRIER PIPE
PIN# 8742-43-0071.000 I w
PARCEL 67033 I t:Gl
O >>
O O 01
O O I
O + r �� ROW—
+ — — ROW— — %
— ROW—
p _ _ — —ROW— ----------- �,% N
O\fJ _—_ — —
----_--_-M-----M- _-
___—_------- __— ---- FM _
FMB �L --DL-- �♦
--- �M- - M---- DL--- �� 5\GN
DL-----DL----- ������� 5\G
F-- ---- DL-----DL---- �����mamlommmmom���
DL----- DL----- m a m
V) ----- w w w
Imawwwwwwwwwwo�
I —
I I PROPOSED BEGIN PROPOSED END ° -- _-__ --M—
, I DIRECTIONAL DRILL DI ECTIONAL DRILL MO�� --�__� ��, o
PIN# 8742-43-0071.000
I c g _ _ +
i I PROPOSED PARCEL 67033 00 +
I o BORE PIT +
I Row— — + N
O O —Row— — + o C14 ' wo
O Row— — + 0)— �, _ _ _ —
— — ROW— "_ _ _ — _ _ — -
- ROW— —ROW TREt ". _ - - _ = "_ M - O - t- - -M -
RI��\S� --ROW--�— — ROW— =- —_--- --_ �a0 i�FM � _-��----DL
cM' — —ROW— _ _ _ _ �� DL----- DL _
I J� rl=_M - M�FM-__-----DL--- DL----- S E
FM
I TREE LINE I I _� - - -GCS " "" "" -- DL----- D -- DL----- DL-,logo
\GN _ —M _ = -- I I _ __ -- --- _ _ a !/
TREE LINE
O S E SIGN FBCY o_o_o—o� —o—o_o 0 0 0_0 0_0 0_0 0 0 0 0 0 0 0_0 0_0 0_0 0 0 0 0_0 0 0 0 0 0 0 0 0 0 0 0
FM
5\ N m. o 0 0_0_0_0_ I PROPOSED LIMITS
�a a � c 'l OF DISTURBANCE
ii \
EXISTING GUARD RAIL ---------------- ---
1 -- DL
- DL-= - DL----- _ -
;; --_
II DL----- DL -
ii--DL----- --
II
O
iv
TEMPORARY
BORE PIT
II -
w PROPOSED 152 LF 30"0 x 0.375" Q
WALL THICKNESS STEEL ENCASEMENT_17 126+00 t~n
v PIPE, BORED AND JACKED WITH 18" 5 w
.I CLASS 250 DIP CARRIER PIPE _ _ G. 2 z
Q PROPOSED AIR/VACUUM RELIEF ---- I •��
TEMPORARY SILT FENCE 11 VALVE (AT ACTUAL HIGH POINT) DL-
PER DETAIL, TYPICAL v 0
PROPOSED 18" C905—DR 21 — — —Row— — v — — —ROW— _-_—__------ Q
II — ROW— —
PVC FORCE MAIN — —Row— —__------
II —�--ROW-- _--
(3' MIN. COVER, TYP.) —Row— — ; ! — — —Row _ --__—__---------
—�— I --ROW-- --
— —ROW—
—
— —ROW—
— —ROW— —
II _--------- ---------------
II
_ —ROW— —�
----------- _-------u----------
NOTE: LOCATIONS OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE ONLY.
—Row--
_ CDO--
A�RO�ATE NT RIGHT—OF—WAY
EXACT LOCATIONS ARE TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR.
——__----__—__—__-------_--
PER NCDOT "AS CONSTRUCTED PLANS"
PROFILE
z
SCALE: HORIZ. 1 "= 50'
O
O
VERT. 1 "= 5'
630
630
w
14-
" 20
PROPO
ED 18" PL
G VALVE
625
625
EXISTING
GROUND
-
620
•—� 620
VALVE (AT
AC7PJAL-
HIGH PnIKI
TN
NMI
615
615
rA
---
----
Mow
--------
---------------
-------------------------
—
-MI6-------
-------------
- -----------
AV
610
PROPOSED 18
C905—DR 21
PVC1 FORCE M
IN
3'
IN. COVEF
_
TYP.
605
PROPOSED 152 LF
30"0 x 0,375
605
ALL THICKNESS
STE
L ENCASEMENT
_
O x 0.37
PROPOSE
65 LF 30
"
CLASS
250 DID
CARRIER
PIPE
PROPOS
D
18 C9
5—DR 21
WALL THICKNESS
STEEL
ENCASEMENTZ2�1
PVC FORCE
MAIN
PIPE BOR
D AND JACKED
WITH
18"
600
3' MIN.
COVER T
CLASS 25
DIP CARRIER
PIPE
600
36"RCP
595
595
590
590
112+00 113+00 114+00 115+00 116+00 117+00 118+00
119+00 120+00 121 +00 122+00 123+00 124+00 125+00
126+00 127+00
r
5 Regional Circle
_. Suite A
Pinehurst, NC 28374
910.295.3159
NC Firm License # C-0459
mcgillassociates.com
DocuSigned by:
12'4 1*4 A'RO,
;; ooFEs°s,o��%=;
_ o 0
°�� SEAL
-o
034999 ° _
— �° a ti \
L°oF ��°J
' i oNCINE�a G
=, o y
/,�� � oHON�`\�\\
5/251�023
��,�gEFORF yo
��`' Goy
, C
Q m
`�' O
9,� ��
F ��
��GGING PP
CHATHAM-RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
TOWN OF SILER CITYOFFICE
50 0 25 50 100
PLAN AND PROFILE FORCEMAIN
STA. 111 +50 TO STA. 127+00
SHEET
C=1 08
GRAPHIC SCALE DIVISION VALUE = 50 FEET
MANAGER
D. HONEYCUTT
DESIGNER
D. HONEYCUTT
2
5/9/23
DLH
NCDOT COMMENTS
1
03/14/23
DLH
NCDMLR COMMENTS
CHATHAM COUNTY, NORTH CAROLINA
PROJECT MANAGER
D. HONEYCUTT
REVIEWER
DATE
DECEMBER 2022
PROJECT #
13.04039
FUNDING #
N/A
NO.
DATE
BY
I DESCRIPTION
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
PLAN
WILLIAM L. SMITH, ETAL
PIN # 8742-43-0071.000
PARCEL 67033
WILLIAM L. SMITH, ETAL
—ROW
M
PIN # 8742-43-0071.000
— —
PARCEL 67033
_
.ROW
BROW
— ROW
ROW�
_
-�
�� ��
°'�
_
ROW—
BROW
—M-----M-- ROW—
_
_
—M 6,. 4ROW,,
ROWS
_
PV�M--_ —ROW�
WATER—M
_�-
S01
i
__M—
O
-I-
- — — — AN-- — DL----
DL-----DL----- �
— DL---- _ DL--'_—
-- DL-----DL--- O
(O
i
SSG O
j/ X
if
lLe
DL--- DL---- O
--M— DL----
--DLL- DL---- ' I 8 I I - � 3
—{DL-----DL--- 0I- ''' lil SIGN ... / so as am
�N1� '~ me _ •
DL----- DL--- O II as R— �� " 1
DL--E� — DL---- } ( II �� / E 1 ��
-- DL---- O o N IIsa*gww�/�F11�__ 5�
N�\ ill s\GN �2l �����to am 10 Rio ����a am " iT'� Row,to so,* woo as' usages
as 10 as
.�
�M
1// 3�
as� o
3
O
4 — 0�
—M
---
LO
p' , ' f
•R.1107 64
SO
aw 2�J
FM --D _ d-
FM
��---DL— (n
FM ���a OFygosi��� �� E LLJ
_ magaalo m�a� -o
-_mome��FM.— ��� aw BROW -� 9 Z
M=��--.*�� — _ —R W_ -�� PROPOSED AIR/VACUUM RELIEF —�
VALVE (AT ACTUAL HIGH POINT)
-ROWS
PROPOSED 18" C905—DR 21
PVC FORCE MAIN PROPOSED LIMITS
(3' MIN. COVER, TYP.) OF DISTURBANCE
APPROXIMATE NCDOT RIGHT—OF—WAY
PER NCDOT "AS CONSTRUCTED PLANS"
NOTE: LOCATIONS OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE ONLY.
EXACT LOCATIONS ARE TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR.
EXISTING I GROUND
PROFILE NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS FOLLOWS.
SCALE: HORIZ. 1 "= 50' SEE EROSION CONTROL DETAILS FOR INSTALLATION AND MAINTENANCE REQUIREMENTS.
VERT. 1 "= 5' LOCATION LINING TYPE MINIMUM WATTLE SPACING
130+50 TO 135+50 NAG S75 MATTING OR EQUAL 30' O.C.
Al
PROPOSED AIR VACUUM RELIE
VA (AT ACTUAL HIGH POIN
655
650
645
640
635
1 630 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 630 1
625 ,
--- ---------- --- ---'' 18"RCP
-- -
---- -- ----- -------------- --
if
5 Regional Circle
Suite A
MC91 Pinehurst, NC 28374
910.295.3159
NC Firm License # C-0459
mcgillassociates.com
PROPOS D 18- C9 5—DR 21
PVC FO ICE MAIN
i-Ff . AIL a e%e%% r—r% -r-%
129+00 130+00 131 +00 132+00 133+00 134+00 135+00 136+00 137+00
DocuSigned by:
\ `�EFORF O CHATHAM-RANDOLPH MEGASITE
52740�L�'� ooI _S. O` i�
000FE '�%t%�o�= SEWER SYSTEM EXTENSION
=oQe-
o SEAL -
O o0 034999 o ,
o
o N ��
���i���GINETOWN OF SILER CITY
��oGJ\. yam,
��oHONE�',\, CHATHAM COUNTY, NORTH CAROLINA
���GGING QP� 1 03/14/23 DLH NCDMLR COMMENTS
\\\\ NO. DATE BY DESCRIPTION
12"RCP
50 0 25 50 100
GRAPHIC SCALE DIVISION VALUE = 50 FEET
OFFICE MANAGER
D. HONEYCUTT
PROJECT MANAGER
D. HONEYCUTT
DESIGNER
D. HONEYCUTT
REVIEWER
625
620
615
5GI1II111iGlel%-Io7
SHEET
PLAN AND PROFILE FORCEMAIN
STA. 127+00 TO STA. 140+50 C=1 09
DATE PROJECT # FUNDING #
DECEMBER 2022 1 13.04039 N/A
co
0
0
co
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
WILLIAM L. SMITH, ETAL
PIN # 8742-43-0071.000
PARCEL 67033
LOCATION AS SHOWN
SHALL BE A MINIMUM 5'
FROM EXISTING CULVERT
0
O
O
O
o
O
O
O
O
—------------
---------
—— -- --
-- —--
-- —ROW -----ROW-----ROW
--
ROW—= ROoW�----
MR W----M ROW
+
M M—
—M— —M—--
-- M—
V
M
—63 — _ 63 —
--
_-- ' — _— 27no-
_ _ -- —
go-60
PLAN
TIM'S FARM & FORESTRY II, LLC
PIN# 8742-51-3256.000
PARCEL 67033
PROPOSED 60 LF 30"0 x 0.375"
WALL THICKNESS STEEL ENCASEMENT
Al PIPE, BORED AND JACKED WITH 18"
0 CLASS 250 DIP CARRIER PIPE
TEMPORARY CHECK
DAM, TYPICAL
k
O O O O O O o
0
O
—
O
O
O O
c0
I�
00
O O
— ROW-- ROW -----
ROW --= —ROW -----
ROW —= --ROW -----ROW
— — —
-----ROW ----ROW ROW---- ROW----
--A�----M-----M-----M-----M-----M—
--- —M----
6M PVC WATER M----M-----M— --M--
621 / 67: 6T
6�0
T 7.'L�Y ��
663Ar
635 636 / 6g8
O o 0
cV EM
I O
)W— f RO6W_=T�iOWT�c— ---�—
M— / M — — — �M_—�M-������ M — �— M-
- \ - - - - - S.R.11G�7 - - - - -r-- - - /
_ --- — — DL --- -- s -- DL----- L= -
-----:111 mill---- �� Mai M ��M M M M
IIJ -- ---- — =rEE —� --� ---
SOW— —ROW— �R= cmm'EROW— ROW— — — — — - 6 — 6 ROW �631 _632� l =633_— W634 —_ — — 0` IM y — —
_ Q S/� Z
EXISTING STREAM I
� I
PROPOSED 18 C905—DR 21
PVC FORCE MAIN
(3' MIN. COVER, TYP.)
WILLIAM L. SMITH, ETAL
PIN# 8742-43-0071.000 BORE AND JACK NOTES:
PARCEL 67033 1. BOTTOM OF BORE PIT SHALL BE MINIMUM 1' H. 1' V. THEORETICAL
SLOPE FROM EDGE OF PAVEMENT OR ACTIVE SHORING MUST BE USED.
2. SPOILS PILE SHALL BE PLACED ADJACENT TO BORE PIT WHERE ROOM
EXISTS WITHIN ROAD RIGHT—OF—WAY OR SEWER EASEMENT. SILT
FENCE SHALL BE INSTALLED AND MAINTAINED ON THE DOWNHILL SIDE
OF THE SPOIL BORE PIT AND SPOIL PILE. CONTRACTOR SHALL PLACE
SPOILS IN DUMP TRUCK OR STORE IN OTHER LOCATION WITHIN
DISTURBED AREA IF ADEQUATE SPACE IS NOT AVAILABLE.
3. CONTRACTOR SHALL NOTIFY ENGINEER IF ROCK OR OTHER UTILITIES
ARE FOUND WITHIN THE BORE AREA PRIOR TO BEGINNING BORE AND
JACK. WHERE CONDITIONS DO NOT ALLOW BORE, ENGINEER MAY
COORDINATE WITH NCDOT TO REQUEST OPEN CUT OF ROADWAY.
650
645
640
635
630
625
620
615
610
141+00
142+00
5 Regional Circle
Suite A
Pinehurst, NC 28374
910.295.3159
Cq NC Firm License # C-0459
mcgillassociates.com
PROPOSED LIMITS
OBIS-URBANCE
PROPOSED STREAM
CROSSING PER
SMALL STREAM
CROSSING DETAIL
_0
6k0 dG 6k1 a r
117 _
o - H
N
3W— — — — —ROW— — ��=ROW— — — — OW —_ ROW- ROW LLI
639-� Z
V TEMPORARY BORE
PIT --/ �� I
�`
;I �
TEMPORARY DROP INLET
PROTECTION PER DETAIL
'
TIM'S FARM & FORESTRY II, LLC
Opp
\.
ASHLEY N SPIVEY
PIN# 8742-51-3256.000
I
LEMONS JOHNNIE IV & DARLENE M I
PARCEL 67033
' w�
\
PIN# 8742-61-9970.000 i
PIN# 1
PARCELCEL13163 000
163
U)
�
PARCEL 13162
PROPOSED GRAVEL DRIVE
'
REPAIR PER DETAIL
'
' I
I
NOTE: LOCATIONS OF EXISTING UTILITIES AS SHOWN ARE
APPROXIMATE ONLY.'
�
i
EXACT LOCATIONS ARE TO BE VERIFIED IN THE FIELD BY
THE CONTR�'CTOR.I '
'
PROFILE
NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS FOLLOWS. SCALE: HORIZ. 1 "= 50'
SEE EROSION CONTROL DETAILS FOR INSTALLATION AND MAINTENANCE REQUIREMENTS.
LOCATION LINING TYPE MINIMUM WATTLE SPACING
140+50 TO 144+50 NAG S75 MATTING OR EQUAL 30' O.C.
145+00 TO 147+40 NAG S75 MATTING OR EQUAL 30' O.C.
EXISTING I GROUND
"RCP
X
w
PROPOSE 60 LF 3 " 0 x 0.37 "
WALL THI KNESS ST EL ENCAS MENT
..... .... ....—. . "
... , ... V. .. V .. VW V V I \V L V V WIN . V.\ NOW V.
MAINTAIN MINIMUM 2' SEPARATION FROM
FORCE MAN TO CULVERT
143+00 144+00 145+00 146+00 147+00 148+00 149+00 150+00 151 +00
—DocuSigned by:
12-- 6,� EFO)l yo CHATHAM-RANDOLPH MEGASITE
—5274 O�1 Oov ooCo oOo%
SEWER SYSTEM EXTENSION
oQ <o
S SEAL o =
ao 034999 o� _ 0
�* C) 9,�, ��� 2 5/9/23 DLH NCDOT COMMENTS
/TOWN OF SILER CITY
Q000 ""Eo °y
HONE��.�`� ���GGING PP�� 1 03/14/23 DLH NCDMLR COMMENTS CHATHAM COUNTY, NORTH CAROLINA
5/25%'2d1� NO. DATE BY DESCRIPTION
152+00 153+00
50 0 25 50 100
GRAPHIC SCALE DIVISION VALUE = 50 FEET
OFFICE MANAGER DESIGNER
D. HONEYCUTT D. HONEYCUTT
PROJECT MANAGER REVIEWER
D. HONEYCUTT
z
154+00
650
645
630
625
620
615
610
155+00
PLAN AND PROFILE FORCEMAIN
STA. 140+50 TO STA. 155+00
DATE
DECEMBER 2022
PROJECT # FUNDING #
13.04039 N/A
SHEET
C IM 110
co
0
0
co
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
FRANCISCO HERNANDEX MUNOZ
PIN# 8742-71-6865
PARCEL 13060
I
PHILIP RAY & NANCY C WILSON I1
IPIN# 8742-71-8636.000
PARCEL 13061 I
I
i I
PROPOSED 18" PLUG VALVE
W/VALVE BOX
I
- PRqPOSED ASPHALT '
DRIVE REPAIR PER DETAIL
i
O O O 0 I00 I
O O O + ' + '1
+ + +
PROPOSED CONCRETE
DRIVE REPAIR PER DETAIL
O
E—
---- ROW—
-----
— ROW— — ROW— —-E— ROW ---
E ROW— ��r- R9ROW�—�
/—ROW—
E=IiOVP==
---- M--� --
j ----M----M--/--M— f
/ /
--M�--
j--M
/
-- G—
�A /7 —
M---
—M—
---M-----M--
��a / fah
�a`� a a� a°j h��h bh`V
6
g� hk / hh 6h6
0 6 0
c^ .6h3 6h$ h9
6
c^
OLD US HWY 64
S.R.1107
Q
�
(%�
DL
- - -�
—M-----M--
--
--6m
-
— W ----
ROW--
--RI OW - 655
—e�—---R�i0656
wwtOtY
_ ROW—�—�=�=��Z
--ROW--i-- ROW—
LU
y
Ua
"
Q fS
a ,o
L
I
I
675
670
665
..c
655
650
645
635
ASHLEY N SPIVEY i CRISTOBAL ANTONIO
HERRERA
PIN# 8742-71-0695.000 I PIN# 8742-71-3454.000
PARCEL 13161 1 PARCEL 13158
I
TEMPORARY INLET
PROTECTION, TYPICAL
156+00
I
TEMPORARY CHECK
DAM, TYPICAL
157+00
5 Regional Circle
Suite A
Pinehurst, NC 28374
910.295.3159
NC Firm License # C-0459
mcgillassociates.com
158+00
—DocuSigned by:
ER 'RO�,,// g)
-52\488\\,1V4 JS�°�/,L
6 ooO
oQV
S SEAL o =
ao 034999 0�
o� N
700°FN yGJ\; y�AA
/,0 °°GINS°° ° .�
������ ��GGING
IIIIIPP
5/25/2023
PROPOSED LIMITS
OF DISTURBANCE
I
I
159+00
EXISTING I GROUND
NO. I DATE I BY
160+00
SANTOS A HERRERA ETUX
VILMA D
PIN # 8742-71-8636.000
PARCEL 13156
A01 ti3 0:Z•):1
i
PLAN
i
o ,
\ WILMA ALSTON TYSON ETUX
�wO \ 1AiI�CEVERETTE L SELLARS LIFE EST _ M WALTER LONG PIN # 8742-81-2393.000
PIN# 8742-81-0494.000 PARCEL 13152 PROPOSED CONCRETE
i W \ PARCEL13153 DRIVE REPAIR PER DETAIL JORDAN GROVE AME ZION CH
PIN# 8742-81-5115.000
W` O , O O O O PARCEL 68796 O
O , O O O O O
---=li�W—--ROW -----ROWS----ROW-----ROW---- ROW---- ROW-----ROW--s —ROW -----R — r— —ROW-
- —M ��— \\ -- — — --- _ ° �� — — --- ----- -- -- —M— —M Lo
F 6 �\ --------� -- -- --
1 -- �_—_—_------//+��
I� E 659 65a �65� 656 65y 654 II — — — 653- — 652 bhp
-DL--� -DL--D DL- --D - --DL-- �''- _ ==Dl-----DL�g50 =-649= 649
FM FI
■i��wtw ����Sw���, �lil�r�lr�w�l� ������■�ww�wwww��wil I wwr■iw �� Q
oW �RDwA.A.��cfl _ — — — — — — _ — _ _ — &OW— _ t9bt — I-
3 '
TREE LINE I I Z
I I J
PROPOSED GRAVEL DRIVE I =
II1 PROPOSED GRAVEL DRIVE �, REPAIR PER DETAIL I c�
PROPOSED 18" C9b5—DR 21 REPAIR PER DETAIL `�'.�
PVC FORCE MAIN
(3' MIN. COVER, T+P.)
I
I
PROPOSED AIR/VA6UUM RELIEF
VALVE (AT ACTUAL HIGH POINT)
MICHAEL ARTHUR MCNEESE
& ETUX PAMELA ENGLISH
JARMAN MCNEESE
PIN # 8742-70-4752.000
PARCEL 13155
NOTE:
LOCATIONS
OF EXISTING
UTILITIES
IS SHOWN ARE
APPROXIMATE ONLY.
EXACT
LOCATIONS
ARE TO BE
VERIFIED
INTHE FIELD BY
THE CONTRACTOR.
PROPOSED 18" C_
PVC FORC MAIN
(3' MIN. COVER.
161 +00
DESCRIPTION
I
JARMAN LYMAN DARDEN
ETUX PAMELA J
PIN# 8742-80-1835.000
I
PARCEL 13107
PROFILE NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS FOLLOWS.
SCALE: HORIZ. 1 "= 50' SEE EROSION CONTROL DETAILS FOR INSTALLATION AND MAINTENANCE REQUIREMENTS.
VERT. 1 "= 5' LOCATION LINING TYPE MINIMUM WATTLE SPACING
156+00 TO 160+00 NAG S75 MATTING OR EQUAL 25' O.C.
162+00 TO 165+50 NAG S75 MATTING OR EQUAL 50' O.C.
VALVE (AT ACTUAII HIGH P
DR 21
162+00 163+00 164+00 165+00
CHATHAM-RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
TOWN OF SILER CITY
CHATHAM COUNTY, NORTH CAROLINA
166+00
167+00
50 0
25 50 100
GRAPHIC SCALE
DIVISION VALUE = 50 FEET
OFFICE MANAGER
DESIGNER
D. HONEYCUTT
D. HONEYCUTT
PROJECT MANAGER
REVIEWER
D. HONEYCUTT
168+00
675
670
665
..0
655
635
169+00 169+50
PLAN AND PROFILE FORCEMAIN
STA. 155+00 TO STA. 169+50
DATE
DECEMBER 2022
PROJECT # FUNDING #
13.04039 N/A
SHEET
M
O
CD
0
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
PLAN
0
rn
rn
co
a
w
z
0
H
Q
650
640
635
630
625
620
615
610
170+00
171+00
5 Regional Circle
Suite A
Pinehurst, NC 28374
910.295.3159
NC Firm License # C-0459
C9 mcgillassociates.com
1 I 1 I
I �
NOTE: LOCATIONS OF EXISTING UTILITIES AS SHOWN ARE APPRO IMATE ONLY.
EXACT LOCATIONS ARE TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR. I '
I I
172+00 173+00 174+00
—DocuSigned by:
/.? gCAREFORF
—s274ZiZ {1!g4 Soo,o
' �� ypG
0 o0 of
o SEAL —
O o0 034999 o , o
o
%��iC, yam,
�HON�.�`�\ ���GGING P2 5/9/23
5/2�%'d2�3 NO. DATE
EXISTING I GROUND
PROFILE
SCALE: HORIZ. 1 "= 50'
VERT. 1 "= 5'
3' MIN.I CO
175+00 176+00 177+00
DLH I NCDOT COMMENTS
BY I DESCRIPTION
NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS FOLLOWS.
SEE EROSION CONTROL DETAILS FOR INSTALLATION AND MAINTENANCE REQUIREMENTS.
LOCATION
170+00 TO 183+50
178+00
LINING TYPE
NAG S75 MATTING OR EQUAL
179+00
CHATHAM-RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
180+00
TOWN OF SILER CITY
CHATHAM COUNTY, NORTH CAROLINA
MINIMUM WATTLE SPACING
50' O.C.
181 +00
182+00
50 0 25 50 100
GRAPHIC SCALE DIVISION VALUE = 50 FEET
OFFICE MANAGER
D. HONEYCUTT
PROJECT MANAGER
D. HONEYCUTT
DESIGNER
D. HONEYCUTT
REVIEWER
183+00
650
645
640
635
630
625
620
615
V
610.
184+00
PLAN AND PROFILE FORCEMAIN
STA. 169+50 TO STA. 184+00
DATE
DECEMBER 2022
PROJECT # FUNDING #
13.04039 N/A
SHEET
C=1 12
M
co
O
O
co
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
\
PLAN
JOHN MARK ELLINGTON
JOHN MARK ELLINGTON
PIN# 8752-00-2145.000
/
PIN # 8752-00-1200.000
PARCEL 13176
PARCEL 13175
SARAVIA MARVIN JAVIER CRUZ
TEMPORARY
PIPL\ INLET
I
ETUX BERTA ALICIA BERRIOS
DE CRUZ
PROTECTION,
TYPAL
I
`\
PROPOSED SOIL DRIVE REPAIR
PIN# 8742-90-7378.000
I I
PARCEL 13143
I
I
\
\
I ,
I
TRIPP COTTAGES PHASE II, LLC
PIN # 8751-09-8887.000
PARCEL 82612
PROPOSED 18" C905-DR 21
PVC FORCE MAIN
(3' MIN. COVER, TYP.)
TEMPORARY RIPRAP CHE
DAM PER DETAIL, TYPICAL
0
0
0
0
0
0
0
0
0
0
I 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
------ -
--
--
Q
Q
00
00
�
00
--------�---
00
00
�__
-- 0 --
-- --
CY)
N
---Q�
M
----- -- -- --- -
�
- p�--
In
-- Qy- --
cp
---�-
+
-- a0- --
-AS—PH-All-
Q
D7
OW -----ROW---=
+
ROW-----ROW----ROW-----ROW—=---ROW-----RO
i ----ROW----BROW-----ROW----r
ROW-----ROW--�--
—ROW
W-----ROW----9�OW-----ROW---
=ROW -----ROW
— �--ROW-----ROW—z-----ROW-----ROWr.
----RO
�
�/ —M----
Mir`---M-----M-----M-----M—
---M-----M----
M — — — — — M ----M----M-----M-----M-----M-----
-----M-----M-----M—
M-----M--
-----M-----M----
M— — M-----M-----M-----M�---
--
—
II
1
\
00
r
610— —
II —61D
— —
OLD US '�iWY 64
Q
Q
615-
61k
/613�
—612
/611i
/ 610
—�iT—
c\ S.R.110
—__ _
,,��
I—
_
—
-
- — —�r3L
— -- n�
EIC
\ -- -
FM
�� _ == QC ---- DL--= D� ---- DL----- DL- �� _ - _L� i
ti -- -D� -- - DL----- DL---- DL=---- g� - f _ - - - -
F�1MFM=DL --- FM _:_:....
— — — —
— R W— — — — RO — ==�iiiDW`—=—�.o..
_ —777
— ZRCC•CIRE - - - - -" -
- - - -- 4—BOJN—
� - - _ _ _ _ _ _—ROW— __-- � iiOV[r=Z
JQ
`\
\\ PROPOSED FORCE MAIN
pF �6��
I PROPOSED GRAVEL DRIVE REPAIR
ROBERT REID GEE
ROSEMBERG SARAVIA I PIN# 8742-90-8045.000
PIN # 8742-90-7009.000 PARCEL 13142
PARCEL 13144
I
I
630
625
620
615
605
•
595
590
\ AT LOC�BE
TION AS SHOWN
\ SHALL A MINIMUM 5'
FROM EXISTING CULVERT
\
a
i
H--I FM— a FM 11�—F��—FM — — — --_ — V)
-- -- ROW, — --R -- =RAW —611" LLI
- 612- -
Z
\ J
\ U
F_
NCC STADIUM, LLC \
\ VILLASENOR ELIZANDRO ETAL
QPIN# 8751-09-2374.000 \ PIN# 8751-09-9096.000
PARCEL 13014 v
PROPOSED AIR/VACUUM\\\ PARCEL 13173
OUTLET PROTECTION
TEMPORARY RIPRAP RELIEF VALVE AT ACTUAL\
HIGH POINT) \
NOTE: LOCATIONS OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE ONLY. \\
EXACT LOCATIONS ARE TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR. \
NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS FOLLOWS.
SEE EROSION CONTROL DETAILS FOR INSTALLATION AND MAINTENANCE REQUIREMENTS.
LOCATION LINING TYPE MINIMUM WATTLE SPACING
188+00 TO 191+00 NAG S75 MATTING OR EQUAL 50' O.C.
191+00 TO 192+75 NAG S75 MATTING OR EQUAL 30' O.C.
18" C905—DRI 21
(3' IMIN. COVER, TYP.)
NG
185+00 186+00 187+00 188+00 189+00 190+00
DocuSigned by:
gEFORF
s2741\�� �3co@9 ARO�''%, �� ypG
5 Regional Circle ; C�oFESsio'°% �Qy'Il, oc
Suite A =°Q� 9�
Cg Pinehurst, NC 28374 =000 034999 °SEAL °� ` Q 0
910.295.3159 ; v F o °�
L °°°°eY F,°e J -9 B
NC Firm License # C-0459 -,�O °c�Noo°°��.�'
mcgillassociates.com HON��.`� GING QP� 2 5/9/23 DLH NCDOT COMMENTS
5/2��%'d23 NO. DATE BY DESCRIPTION
PROFILE
SCALE: HORIZ. 1 "= 50'
VERT. 1 "= 1'
RELIEF VALVE (AT ACTUAL
TOWN OF SILER CITY
CHATHAM COUNTY, NORTH CAROLINA
195+00
196+00
50 0 25 50 100
�%e6l! i�
1 11 ! ' iiiiii
GRAPHIC SCALE DIVISION VALUE = 50 FEET
OFFICE MANAGER
D. HONEYCUTT
DESIGNER
D. HONEYCUTT
PROJECT MANAGER
D. HONEYCUTT
REVIEWER
197+00
630
198+00 1
PLAN AND PROFILE FORCEMAIN
STA. 184+00 TO STA. 198+50
DATE
DECEMBER 2022
PROJECT # FUNDING #
13.04039 N/A
SHEET
C=1 13
co
O
0
co
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
Ile
\, \\
� \
PLAN
\
PIN#
,
\ \
PACEL i-
,
\
,
----W-----W ----W
___ _ ---W
-W
\ TIMMER 1717 LLC �` N
PIN# 8751-19-8781.000 PROPOSED\R/VACUUM RELIEF
TEMPORARY RIPRAP CHECK I
,\ PARCEL83929 VALVE (AT ACTUAL HIGH POINT)
DAM PER DETAIL, TYPICAL
TEMPORARY PIPE INLET
PROPOSED 45 LF 30"0 x 0.375"
'`Lo
I I
DONALD R SIMPSON
PROTECTION, TYPICAL
�WALL THICKNESS STEEL
�, I
I
BARBARA H SIMPSON
PIN# 8751-19-4687.000
\ ENCASEMENT BORED AND
PROPOSED BEGIN\ o
JACKED WITH 18 CLASS 250
DIRECTIONAL DRILL `,
� o
I I
PROPOSED 18" C905-DR 21
D.I.P. CARRIER PIPE
\�
I -
�__ O �'
LO
r --- +
`�W- +
o , I
PVC FORCE MAIN
PROPOSED 18" PLUG
O
O
o -cLl-
O �-1
--M
�+ o I I
(3' MIN. COVER, TYP.)
VALVE W/VALVE BOX
+
__�--�--ROW
_—ROW—�—
M=----N—
_ oW �CA-N Row �9
N
'r' _-�W� —� + I
�� M -�-_
_-
O O � -� ROW—
-��\=
--��
— —ROW _—M N_---M— ----
=-----
—� 5g2,/
�� Q
G1p
D1 °
= W O
\—=ROVI�=—___ + Q�--
O O
O
_
O O _ _® -�
__-- -- + _W____—ROW----M
—M
-----——
I ��— -582 _—
—
e►
__R�W --� N I
�� \
- ---- ----{3 ------
--�_----�__
O— = R®M M==--ROM---__M—_
582-----
5\GN------------
—
--ro
\ W�
/ R O ASP�ALT
, pry
OOW��
ROW---
Mi
—
—
Z
(� --
60 \ �M ��—R =
v 6p� \� \
--—\ --
�— \s�
_ 1NR4W---
s9i S9o---Sdd� V
W—
-----
_— — s ss s�� / 1-581——__-=—�-;
f -�
— — — 581- —
��
J
Lv
/// /> \
�� s`99
/
\ -W--
US S� Q �\ \
�� \
17--o. 8---sd,
\ \ \
OLD
s w z 58
da'. s I/ // // eJ♦ S-� ------
— — __ rn
_ -- — �� — ---_-- / 1 \
' ff �' i
V
�. _
_ _ _ _ / / / / \
i
�� s \ \
\ HWY -4
S.R.ix07
> > / _ —_ = t_Y _ =—
/ /
/1=
_ — — �_ / i /. ////
/50
Q
J
��_ /��
i
_
—
_ �/ °� I
rin ���
/\
- ____ __
'
i�ftOW
i
0
CrS�
31 PROPOSED BORE PIT
I z
PROPOSED END
,
�� 11 I
TEMPORARY SILT FENCE I o DIRECTIONAL DRILL
O
;
BORE AND JACK NOTES:
J
PER DETAIL, TYPICAL
/
1.
BOTTOM OF BORE PIT SHALL BE MINIMUM 1' H. 1' V. THEORETICAL
\ III
I
CO
SLOPE FROM EDGE OF PAVEMENT OR ACTIVE SHORING MUST BE USED.
VILLASENOR ELIZANDRO ETAL
III WOMBLE LIESEL ESTATE
I
2.
SPOILS PILE SHALL BE PLACED ADJACENT TO BORE PIT WHERE ROOM
PIN# 8751-09-9096.000
I D 4.000
PIN# 8751-18-981
I PARCEL 1381
EXISTS WITHIN ROAD RIGHT-OF-WAY OR SEWER EASEMENT. SILT
PARCEL 13173
I
PROPOSED 350 LF 20" DR 9
FENCE SHALL BE INSTALLED AND MAINTAINED ON THE DOWNHILL SIDE
3
I I
DPE FORCE MAIN INSTALLED
/-
OF THE SPOIL BORE PIT AND SPOIL PILE. CONTRACTOR SHALL PLACE
I
BY DIRECTIONAL DRILL
SPOILS IN DUMP TRUCK OR STORE IN OTHER LOCATION WITHIN
I
DISTURBED AREA IF ADEQUATE SPACE IS NOT AVAILABLE.
3.
CONTRACTOR SHALL NOTIFY ENGINEER IF ROCK OR OTHER UTILITIES
ARE FOUND WITHIN THE BORE AREA PRIOR TO BEGINNING BORE AND
JACK. WHERE CONDITIONS DO NOT ALLOW BORE, ENGINEER MAY
COORDINATE WITH NCDOT TO REQUEST OPEN CUT OF ROADWAY.
NOTE: LOCATIONS OF EXISTING
U ILITIES AS SHd N ARE APPROXIMATE ONLY.
EXACT LOCATIONS ARE TO BE
V RIFIED IN HE I IELD BY THE CONTRACTOR.
630
630
600
1
600
INSTALL TEMPOR ARY
LES IMAINTENANCE DRAINAGED AS FOLLOWS.
PROFILE
DETAILSCFORNING
S�E EROSION CONTROLTE:
EITCH QUIREM NTS..
IN TALLAT ONANDTTAND
SCALE:
HORIZ. 1 "= 50'
LOCATION LINING TYPE MINIMUM WATTLE SPACING
VERT. 1 "= 1'
199+00 TO 206+00 NAG S75 MATTING
OR EQUAL 30' O.C.
625
625
595
595
S
LVE
PRO
OSED
620
620
590
590
STALLED
Y DIRECTI NAL DRIL
��
PROPOSED
AIR VACU
M RELIEF
I
VALVE (AT
i1GH
POINT)
585
615
615
*6
EXISTING
GROUND
EXISTING GROUND
610
— 5-80
610
580
N.
- - - -
- - - - - -
PROPOSE
18 C90
—DR 21
PVC FOR
E MAIN
—
----
3' MIN.
OVER T
.
7N
605
605
575
NEE=
575
I
600
600
570
570
E
EMEN
595
595
565
565
IE
PIPF
590
-1 590
560
560
PROPOSED 18'
C905—DF
21
FORCE MAIN
PVC0
585
555
555
199+00 200+00 201+00 202+00
203+00 204+00
205+00
206+00 207+00 208+00 209+00
210+00 211+00 212+00
213+00 213
50
r
DocuSigned by:
11till
CHATHAM—RANDOLPH MEGASITE
50 0 25 50 ,00
SHEET
5 Regional Circle
5274Q�C�Ai9°6��D°rJ°s10
oe°o
1<:y
V , C
SEWER SYSTEM EXTENSION
PLAN AND PROFILE FORCEMAIN
GRAPHIC SCALE DIVISION VALUE = 50 FEET
Suite A
Pinehurst, NC 28374
°Q� =
= S SEAL o =
= 0 034999 0
00
, 0
TOWN OF SILER CITYOFFICE
STA. 198+50 TO STA.
213+50
C=1 14
MANAGER
DESIGNER
910.295.3159
NC Firm License # C-0459
: �iVGINE 0' C,
-, O °°°°°°°°
9,�� ,<��
D. HONEYCUTT
D. HONEYCUTT
2
5/9/23
DLH
NCDOT COMMENTS
1
03 14 23
/ /
DLH
NCDMLR
COMMENTS
CHATHAM COUNTY, NORTH CAROLINA
PROJECT MANAGER
REVIEWER
DATE
PROJECT#
FUNDING#
mcgillassociates.com
/'/ii`• HON��``��
51z��%'2fj2�����`
��G QP�
GING
NO.
DATE
BY
DESCRIPTION
D. HONEYCUTT
DECEMBER 2022
13.04039
N/A
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
BORE AND JACK NOTES: I �� PLAN
I
1. BOTTOM OF BORE PIT SHALL BE MINIMUM 1 H. : 1 V. THEORETICAL
SLOPE FROM EDGE OF PAVEMENT OR ACTIVE SHORING MUST BE USED. I,
2. SPOILS PILE SHALL BE PLACED ADJACENT TO BORE PIT WHERE ROOM
WOMBLE LEISEL ESTATE ET AL &
EXISTS WITHIN ROAD RIGHT—OF—WAY OR SEWER EASEMENT. SILT
I \ WOMBLE BURDINE ESTATE &SHORT I
FENCE SHALL BE INSTALLED AND MAINTAINED ON THE DOWNHILL SIDE PIN# 8751-39-0410
OF THE SPOIL BORE PIT AND SPOIL PILE. CONTRACTOR SHALL PLACE I PARCEL 13105 I
SPOILS IN DUMP TRUCK OR STORE IN OTHER LOCATION WITHIN 1 I WOMBLE LEISEL ESTATE ET AL &
DISTURBED AREA IF ADEQUATE SPACE IS NOT AVAILABLE. I JANE W TRIPP & ROBERT I WOMBLE I 1 WOMBLE BURDINE ESTATE & SHORT
3. CONTRACTOR SHALL NOTIFY ENGINEER IF ROCK OR OTHER UTILITIES ' I PIN# 7971.000 PIN4
ARE FOUND WITHIN THE BORE AREA PRIOR TO BEGINNING BORE AND PARCEL
1310
�\ 1 # 8751-39-0N
PARRCEL 131 I PARCEL 13105
JACK. WHERE CONDITIONS DO NOT ALLOW BORE, ENGINEER MAY q
COORDINATE WITH NCDOT TO REQUEST OPEN CUT OF ROADWAY.
TEMPOR ' PI
Y RIPRAP CHECK JANE W TRIPP z' I
Al N# 8751-28-5985.000
DAM P�'DETAIL, TYPICAL PARCEL 13132 'z
wl
/ I \ ASPH/�LT _00 O O I C)
O
O I
O O O O 1 D 00
+ + O O O
+ + O
-- — -- --� — -- -- --0 -- -- 00 __ _ __ O __ O + ' + + O O O
+
ROW— — Nrtt ------ROW-- N--ROW-----ROW—� —ROW-----RONF�-----ROW-----I%W-----ROW -- N ROW -----ROW-- N--ROW-----ROW—�--- 1 N---------N-----------�d------- --------------- LO + O 0
Ydh1 --- Co --i'------
--- M ————
M-----M-----M—————
ROW— ROW-�`.H---ROW-----R(4{M-----ROW----�'JROW-----ROW----N ROW -----ROW N — —ROW—
r- M———M-----M-----M-----M-----M--- M----- < _ W-----W-----W
N - __ r M-6---M-----M-----M M� W-----W----- +
-f---- -- ---- v6� ---- — N
QOFM
y83 yak Ch$h ha6 h�1 h$e �h�� y�o `h�� ��9� h9� �`�� �� h°� h°^ h� W / y9e /OLD US H 64 602, vry °° o" — s — s w— _ _ w— — — —
�� — 595 — W
S.R.110 m 9
_FM� — -- ----_ — — _ — — — Q
W i i -p - i i!^�_�---- — — `_ FN ''�----H—fir _ �j _-_ _== ===__ _ -----� -- — — — --- - — F-
_ w
a I o U E E E F y 0 Sg �- Z
I I v Y
/
WOMBLE LEISEL ESTATE ET AL &
WOMBLE BURDINE ESTATE & SHORT
PIN # 8751-39-0410
PARCEL 13105
610
605
.9c
PROPOSED ASPHALT
DRIVE REPAIR
WOMBLE LEISEL ESTATE ET AL &
WOMBLE BURDINE ESTATE & SHORT
PIN # 8751-28-6544.000
PARCEL 13106
610 1 620
605 1 615
I W
U
PROPOSED BORE PIT o ~
PROPOSED 18" C905—DR 21 PROPOSED AIR/VACUUM Z �
0
PVC FORCE MAIN RELIEF VALVE (AT ACTUAL
(3' MIN. COVER, TYP.) HIGH POINT)
WOMBLE LEISEL ESTATE ET AL &
WOMBLE BURDINE ESTATE & SHORT
PIN # 8751-39-0410
PARCEL 13105
I
I
I
I
T OTE: LOCATIONS OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE ONLY.
XACT LOCATIONS ARE TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR.
�Q at
CO
Q PROPOSED 60 LF 30"0 x 0.375' /-
2 WALL THICKNESS STEEL m
ENCASEMENT, BORED AND
JACKED WITH 18" CLASS 250
D.I.P. CARRIER PIPE
I
PROFILE
NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS FOLLOWS.
SCALE: HORIZ. 1 "= 50'
SEE EROSION CONTROL DETAILS FOR INSTALLATION AND MAINTENANCE REQUIREMENTS.
VERT. 1 "= 1'
LOCATION LINING TYPE MINIMUM WATTLE SPACING
213+00 TO 221+00 NAG S75 MATTING OR EQUAL 30' O.C.
222+00 TO 226+00 NAG S75 MATTING OR EQUAL 50' O.C.
PROPOSED AIR VACUUM
RELIEF VALVE AT ACTUAL
HIGH POINT) _-4-
620
615
610
595
605
EXISTING GROUND
605
595
PROPOSED
60 LF 30"0 x
0.375"
LL
Q
WALL THICKNESSSTEEL
ENCASEMENT, BORED
AND
590
EXISTING
GROUND��
59
600
--���
`
ACKED WITH 18" CLASS
250
600
585
585
595
— — —
595
_
_
580
580
PROPOSED 18" C905
DR 21
7_7
PVC FORCE MAIN
(3' MIN. COVER, TYP
575 PROPOSED 18" C905—DR 21
PVC FORCE MAIN
(3' MIN. COVER, TYP
570
214+00 215+00 216+00
DocuSigned by:
�Lt GC A R
5 Regional Circle 527 o ofBss�o���� ;-
Suite A =olz
Pinehurst, NC 28374 = a oo 034999 SEAL
910.295.3159 ; -v F
L °°°°N F,°e J
NC Firm License # C-0459 -,�O °�! oo
C9
mcgillassociates.com '��HO
'N�\,.`��
575 1 585
570 1 580
217+00
2 5/9/23 DLH
1 03/14/23 DLH
NO. DATE BY
218+00
219+00
NCDOT COMMENTS
NCDMLR COMMENTS
DESCRIPTION
220+00 221 +00 222+00 223+00
CHATHAM-RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
TOWN OF SILER CITY
CHATHAM COUNTY, NORTH CAROLINA
224+00
225+00
50 0
25 50 100
GRAPHIC SCALE
DIVISION VALUE = 50 FEET
OFFICE MANAGER
DESIGNER
D. HONEYCUTT
D. HONEYCUTT
PROJECT MANAGER
REVIEWER
D. HONEYCUTT
226+00
227+00
585
580
50
PLAN AND PROFILE FORCEMAIN
STA. 213+50 TO STA. 227+50
DATE
DECEMBER 2022
PROJECT # FUNDING #
13.04039 N/A
SHEET
C=1 15
co
O
0
co
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
BORE AND JACK NOTES: ------ � PLAN
1. BOTTOM OF BORE PIT SHALL BE MINIMUM 1' H. 1' V. THEORETICAL
\ 1
SLOPE FROM EDGE OF PAVEMENT OR ACTIVE SHORING MUST BE USED.
2. SPOILS PILE SHALL BE PLACED ADJACENT TO BORE PIT WHERE ROOM
EXISTS WITHIN ROAD RIGHT—OF—WAY OR SEWER EASEMENT. SILT l
FENCE SHALL BE INSTALLED AND MAINTAINED ON THE DOWNHILL SIDE \`
OF THE SPOIL BORE PIT AND SPOIL PILE. CONTRACTOR SHALL PLACE I RAY SMITH & I I I
SPOILS IN DUMP TRUCK OR STORE IN OTHER LOCATION WITHIN C A BOURTNEYD LEWIS ITBILLY
CHELL TUX BROOKS HERNANDEZ BARTOLO JACINTO \ I, ANN P
LOPEZ ETUX MAYRA L LOPEZ \ RANDY DEAN GAINES , PIN# 8751-48-3223.000 ' 1
DISTURBED AREA IF ADEQUATE SPACE IS NOT AVAILABLE. PIN# 8751-48-0419 I PIN# 8751-48-1229 PIN# 8751-48-2235
3. CONTRACTOR SHALL NOTIFY ENGINEER IF ROCK OR OTHER UTILITIES PARCEL 13084 i I PARCEL 13141 ILLY RAY SMITH -� ANN P I ALVAREZ—AVENDANO ADRIAN &
i PARCEL 61202 \ PARCEL 66313 i 1 ANA LEIDI CHIRINO—ULLOA 1
ARE FOUND WITHIN THE BORE AREA PRIOR TO BEGINNING BORE AND , i ANN P PIN# 8751-48-4181.000 ' PIN 8751-48-6049.000
JACK. WHERE CONDITIONS DO NOT ALLOW BORE, ENGINEER MAY I I IN# 8CEL 133165.0�0 PARCEL 13165 � BI LY RAY SMITH PARCEL 13166
COORDINATE WITH NCDOT TO REQUEST OPEN CUT OF ROADWAY. PARCEL 13204 1 1
Tr• 111A11 • -II 1111111 •'1 AI IrAI/
Al
O
L
N
N
Q
H
V)
W
Z
J
2
U
I —
a
625
610
605
TEMPORARY PIPE INLET
PROTECTION, TYPIOAL
I Ii I
I II
I I
I I I
I I
II I
I I I
I I
I
I I
I � �
I
I
I
I
I
EXISTING GROUND
i
PROPOSED 80 LF 30�\ x 0.375 ANN P PRbPOSEDl 18 C905—DR 21
11
22 WALL THICK ESS STEEL I I Ply # 8751-48-4114.0go PVq FORC� MAIN I
ENCASEMENT, BORED AND IPACEL 13205 3' ,MIN. C 9 VER, TYP.
JACKED WITH 18" CLASS 250 ( Q
D.I.P. CARRIER PIPE I I
PIN# 8751-47-3763.000
PARCEL 13164
NOTE: Lff��CA�TIONS OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE ONLY.
EXACT xOC/XTIONS ARE TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR.
PROFILE
SCALE: HORIZ. 1 "= 50'
VERT. 1 "= 1'
625 1 655
PROPOSED 8 LF 30-0 x 0.375"
Q WALL THICKNESS STEEL
ENCASEMENT, BORED AND
JACKED WIIH 18 CLASS 250 1 1.11I
-'r
610 1 640
605 1 635
DONNA P TRIPP
PIN# 8751-48-7085.000
PARCEL 13168
U1\I YL I\LI r%ll\
NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS FOLLOWS.
SEE EROSION CONTROL DETAILS FOR INSTALLATION AND MAINTENANCE REQUIREMENTS.
LOCATION LINING TYPE MINIMUM WATTLE SPACING
227+50 TO 234+00 NAG S75 MATTING OR EQUAL 25' O.C.
235+00 TO 240+00 NAG S75 MATTING OR EQUAL 25' O.C.
II
1
1
1
I
1
1
1
1
I
1
IPEGGY K ELIASON CHESHIRE
1 PIN# 8751-47-9943.000
I
PARCEL 13169
1
1
ROGER W KEY
PIN # 8751-47-5225.000
PARCEL 13209
655
Jr i
600 600 630 �630
i
PROPOSED 18" C90 —DR 21
PROPOSED 18" C905—DR 21 PVC FORCE MAIN
595 �� PVC FORCE MAN 595 625 3' MIN. COVER, TY 625
(3' MIN. COVER TYP. 00
i
io
590 620 620
owl
585 585 615 615
228+00 229+00 230+00 231 +00 232+00 233+00 234+00 235+00 236+00 237+00 238+00 239+00 240+00 241 +00 242 00
DocuSigned by: 50 0 25 50 100 SHEET
EFORF CHATHAM-RANDOLPH MEGASITE
s274o�ClkJ9 4 .. A..��/; y4G
5 Regional Circle ; o0 oF�ss/oti°°? Qom, o� SEWER SYSTEM EXTENSION PLAN AND PROFILE FORCEMAIN
Suite A : °Q� o SEAL 1� °� , C GRAPHIC SCALE DIVISION VALUE = 50 FEET STA. 227+50 TO STA. 242+00
Pinehurst, NC 28374 = a o0 034999 0 , TOWN OF SILER CITYOFFICE MANAGER DESIGNER
910.295.3159 = -v ° /' N
D. HONEYCUTT D. HONEYCUTT C=1 16
' D°F F� ° J 9 2 5 9 23 DLH NCDOT COMMENTS
°°°°GINS°°°° G .c� / /
NC Firm License # C-0459 O °°°°°°° ��\\\�� �'� PROJECT MANAGER REVIEWER DATE PROJECT # FUNDING #
Mcgimcgillassociates.com 5/251�0 3 O�GGING PP 1 03/14/23 DLH NCDMLR COMMENTS CHATHAM COUNTY, NORTH CAROLINA
NO. DATE BY DESCRIPTION I I D. HONEYCUTT DECEMBER 2022 13.04039 N/A
Q
z
0
Q
U
_
O
z
z
D
O
U
Q
_
Q
U
U
w
J
U)
LL
O
z
O
Z
O
U)
z
w
x
w
75
w
U)
U)
w
w
U)
co
O
O
co
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
670
665
_a@
655
650
645
640
630
, � 3
I
i PLAN
' I I
I I I
I I I
II ,
I � I
I I J
IBENJAMIN E GREER &
2
I
3 1 '
DENNIS W GREER JR HEIRS '------- I I I , JAMES RANDALL GILLILAND I
I ' RICHARD MERRITT PIN# 8751-67-0821.000
PIN# 8751-58-1037.000 I I PACHECO KRISTA MICHELLE I
I PACHECO JACOB WILLIAM VIRGINIA F MERRITT , I PARCEL 13201
PROPOSED 125 LF 36"0 x 0.375"
WALL THICKNESS STEEL
ENCASEMENT PIPE, BORED AND
JACKED WITH 18" CLASS 250 DIP
CARRIER PIPE
PARCEL 13182 I JOYCE H BINKLEY I JAIMES EDUARDO ANGUTANO & I I I PIN# 8751-57-8714.000 I I , I
TEMPORARY PIPE INLET ETUX ANALI VELLAJO REAL , PIN# 8751-57-6756.000 ,
IPROTECTION, ,►TYPICAL PIN# 8751-57-3986.000 I PIN# 8751-57-5709.000 I PARCEL 13215 I PARCEL 13219 i I I
PARCEL62920 I I I TEMPORARY SILT I '
' PROPOSED 18" PLUG � PARCEL 13214 I I '
VALVE W/VALVE BOX PROPOSED AIR/VA�UUM RELIEF FENCE, TYPICAL I I BAR131 z056 35
VALVE (AT ACTUALI HIGH POINT)
I I I I CI II II II E o Oo o+PROPOSED 11890 -DR 21 DRIVE REPAIR O +
PROPOSEDCONCRETE to
-- I
- won• �_- --E _E - _Iilj-= = :-iW!��a �/\1a_ \o�\ �/L-�/ �--y0-- \-— -=i _- y=�L =oPVC FORCE MAIN +LR'—Row—
)owEp (3' MIN. CQVER, TY'.) o + Row— W+
O + R
O + -RO WO O
-�--W_ 0y CICIROW j O �
��a Row � OI O
+' Lfl—I J- W S'/-643 W o d)
�+ + - - - - - - - - -
�ROW_O
44 -_-�ROW_<W flQA
10
I ROW- -- -- --CRO ---Rnw--W-----W---
i -BAW-- -ROW-- ---W- - -- --- - - __
E
E - - - - - - ASPHAL 6ul
6
— --- ----------t------ 645 OLD US HWY 6 ,,_--
- — < 48 6R 64 s S.R.1107
> i— FM r�
645 / -� - F=FM F1A _ F,--E�64�
PROPOSED GRAVEL
TEMPORARY RIPRAP
�—SI DRIVE REPAIR
CHECK DAM PER I PROPOSED FOR MAIN AT LOCATION
I DETAIL, TYPICAL EXISTING 8" FORCE ' AIN I N.,,�60s95s2 1 AS SHOWN SHALL BE A MINIMUM OF
I T I GTIPF
PROPOSED GRAVEL 0 5 FROM EXISTING CULVERT
I ' ' N UINN
WILLIAM WAYNE MANESS ETUX ' MARY R PARKS B ' I 1 & VICKI A
I
DRIVE REPAIR I ASHLEY SHAN MANESS I I PARKS ROBERT EDWARD PIN# 8751-57-3377.000 '� ', ROBERT MELVIN QUINN PIN# 8751-57-8597.000 I
PIN# 8751-57-3610.000 I , FRANKIE MATTHEWS & VICKI A
LIFE ESTATE I i PARCEL 13213 I ETUX MARGARET C PARCEL 13220
, PARCEL 62982 ROBERT MELVIN QUINN PIN# 8751-57-7565.000 I
PIN# 8751-47-9390.000
PROPOSED GRAVEL I PIN# 8751-57-6500 & VICKI A I
IPARCEL 13211 I DRIVE REPAIR i PARCEL 13208 PIN# 8751-57-7565.000 I PARCEL69685 1 I
I PARCEL 69685
PROPOSED FORCE MAIN AT LOCATION
I AS SHOWN SHALL BE A MINIMUM OF I I -_---
I
i 5' FROM EXISTING CULVERT
2 �I
NOTE: LOC TIONS OF EXISTING UTILITIES AS SHOWN ARE PPROXIMATE ONLY.,-__ '
EXACT LOC TIONS ARE TO BE VERIFIED IN THE FIELD BY �HE CONTRA1
I I I
►_1AIZi?2
EXISTING GROUND
/
�� o �',�irtiur`-� Tom- 6 SIGN � �►
1 � U
O Q
I PROPOSED
w PA BORE PIT
PI
RONALS MARTIN ZICH ETUX
PAMELA EMERSON ZICH
PIN # 8751-67-0455.00 BORE AND JACK NOTES:
RCEL 12909 1. BOTTOM OF BORE PIT SHALL BE MINIMUM 1' H. : 1' V. THEORETICAL
SLOPE FROM EDGE OF PAVEMENT OR ACTIVE SHORING MUST BE USED.
PROPOSED OPEN CUT 2. SPOILS PILE SHALL BE PLACED ADJACENT TO BORE PIT WHERE ROOM
SMALL STREAM EXISTS WITHIN ROAD RIGHT-OF-WAY OR SEWER EASEMENT. SILT
CROSSING PER DETAI FENCE SHALL BE INSTALLED AND MAINTAINED ON THE DOWNHILL SIDE
OF THE SPOIL BORE PIT AND SPOIL PILE. CONTRACTOR SHALL PLACE
SPOILS IN DUMP TRUCK OR STORE IN OTHER LOCATION WITHIN
DISTURBED AREA IF ADEQUATE SPACE IS NOT AVAILABLE.
3. CONTRACTOR SHALL NOTIFY ENGINEER IF ROCK OR OTHER UTILITIES
ARE FOUND WITHIN THE BORE AREA PRIOR TO BEGINNING BORE AND
JACK. WHERE CONDITIONS DO NOT ALLOW BORE, ENGINEER MAY
COORDINATE WITH NCDOT TO REQUEST OPEN CUT OF ROADWAY.
PROFILE
NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES
IN DRAINAGE DITCH AS FOLLOWS.
SCALE: HORIZ. 1 "= 50'
SEE EROSION CONTROL
DETAILS FOR INSTALLATION AND
MAINTENANCE REQUIREMENTS.
VERT. 1 "= 1'
LOCATION
LINING TYPE
MINIMUM WATTLE SPACING
242+50 TO 245+50
NAG S75 MATTING OR EQUAL
30' O.C.
246+00 TO 248+00
NAG S75 MATTING OR EQUAL
30' O.C.
253+00 TO 255+00
NAG S75 MATTING OR EQUAL
30, O.C.
PRaPOSED 18'1 C905—DR 121
PVa FORCE MAIN
1 /
1
0 P�ENCASEIAENT
OSED 125 LF 36"0 x 0.37 It
2 ALL THICKNESS STEEL
PIPE, BORED AND
CARRIER PIPE
670
665
.a
655
640
635
630
243+00 244+00 245+00 246+00 247+00 248+00 249+00 250+00 251+00 252+00 253+00 254+00 255+00 256+00 256 50
DocuSigned by:
50 0 25 50 100 SHEET
�, NN" "R'��,,,, ,�eEFoRF CHATHAM-RANDOLPH MEGASITE
52746�,\1-,��C�$B S% O ��/ '; y0G
5 Regional Circle =o&oF oti9 �;; �Q� oc SEWER SYSTEM EXTENSION GRAPHIC SCALE DIVISION VALUE = 50 FEET PLAN AND PROFILE FORCEMAIN
Suite A =
SEAL = STA. 242+00 TO STA. 256+50
Pinehurst, NC 28374 = a o0 034999 0 , o OFFICE MANAGER DESIGNER
910.295.3159 = -v ° o°� N
':�i°o�ciNE��°°°J:' 9,� �� 2 5/9/23 DLH NCDOT COMMENTS TOWN OF SILER CITY- D. HONEYCUTT D. HONEYCUTT C=1 17
NC Firm License # C-0459 O ° �,� F
''�;°HON'-1111100\o \ /GGING QP� 1 03/14/23 DLH NCDMLR COMMENTS CHATHAM COUNTY, NORTH CAROLINA PROJECT MANAGER REVIEWER DATE PROJECT# FUNDING#
mcgillassociates.com 5/25/2023 NO. DATE BY DESCRIPTION D. HONEYCUTT DECEMBER 2022 13.04039 N/A
M
co
0
v
0
co
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
CHRISTOPHER ALLAN LONSKI
CARRIE L VANDYKE-LONSKI
PIN # 8751-67-5974.000
PARCEL 63007
I ,
� I
PLAN
I ,
� I
I ,
� I
I ,
I ,
PROPOSED 18" C905-DR 21 J I
PVC FORCE MAIN I
(3' MIN. COVER, TYP.)
0
0
+
0
0
O
0
+ +
L0
+
ROW— — — _ 00
E ROW— _ _ _ —ROW—
CO
E
— -W—
E
ROW-----ROW—�
_
=�-W _
—
-�
_
E
E
N
'0 55
i 6
6 `
'0 h g�
---W—
9
---- W
Q
--�5 —--S�---��
—S ��
�
`sue --
660_
-- =S
�H
V/
`
- l
- FM FM
Z
I
_J
I
I
cQ
c
I
ELLA KAY GREENE
q 8751-67-3367.000
PARCEL 63011
670
645
640
635
630
I
1
I
I
I
I
I
I
HARRY LEES HORNEY &
JEAN S
PIN # 87 1-67-4022
PARCE� 62928
I
I
I
1
I
I
I
FREDERICK J HAYHURST ETUX
MICHELLE J
PIN # 8751-67-5292
PARCEL 62930
,� I
TEMPORARY PIPE INLET �' SANDEL CORPORATION i SANDEL CORPORATION
PROTECTION, TYPICAL /-' PIN# 8751-67-9684.000 I PIN# 8751-78-2168.000
PARCEL 83875 I PARCEL 15704
PROPOSED ASPHALT DRIVE /'"
PROPOSED SILT FENCE
REPAIR
PER DETAIL
0
0
+
+
0 0
/'�
+
+
�
WE--—ROW
-- —+
- U)-
—E�kOW-----ROW—
i;g
—�— ROW -----
E
ROW ---- ROW -----O
;
�—
E
� --
ROW -------- sr W----------
—ROW ----- ROW S --- -----
ROW----
E
— — — W — —
— — — W — — — —
— W----6W-- ---W-----W—
—— W--E --W—W — — — — —
—E ---—O--E
W— —
— — — W —
OLD US Hn i 64
Aso
_ S— — S_
/
ro
— S— —
TS _
-- --_ 655 �j �� 650 I I °WV
--_--_ , I
_---- - 1
a
I �1
I /
' PROPOSE�EPIAIR
I ASPH LT DRIVE L
I P�R DETAIL
CHECK
I 1
DAM PERRDETTAI RIPRAPTYPICAL
II
CLARENCE MAHLON SNIDER ' MAGRUDER KATHRY
CLARENCE MAHLON SNIDER ETUX ETUX GERALDINE WILLIAMS I I I D M MRS
GERALDINE WILLIAMS SNIDER I SNIDER ,
I I PIN # 8751-77-2307.000
PIN# 8751-67-8460.000 , PIN# 8751-77-0399.000 i I PARCEL 16182 `I
PARCEL 12910 I PARCEL 83876
, , 1
—PROPOSED AIR/VACUUM RELIEF I I 11
VALVE (AT ACTUAL HIGH POINT) I 1
_----__----------- NOTE LOCATIO S OF EXISTING UTILITIES, A SHOW ARE APPROXIMATE ONLY.
EXACT LOCATIONS ARE TO BE VERIFIED P HE FI LD BY THE CONTRA TOR.
1
PROPOSED AIR/VACUUM RE IE
VALVE fAT ACTUAL HIGH P IN
PROPOSE 18" C
PVC FOR E MAIN_
(3' MIN. OVER,
1
PROFILE
SCALE: HORIZ. 1 "= 50'
VERT. 1 "= 1'
665 1 655
635
630
635 1 625
630 1 620
1
1
PROPOSED FORCE MAI AT
LOCATION AS SHOWN §HALL
BE A MINIMUM 5' FROND
EXISTING CULVERT `
JESSICA C LOPEZ 1
PIN# 8751-77-3305.000 `
1
PARCEL 16181 1
1
1
1
1
1
\
\
` MARBEAU
PROPERTIES, LLC
\
MITCHELL EARL DORSETT
\ PIN#
8751-77-7672.000
`
\
PIN 8751-77-6673.000
#
, PARCEL 15716
`\
\
PARCEL 62949
PROPOSED ASPHALT DRIVE`
REPAIR
PER DETAIL
\`
\
\
\
00
0
0 `
rn
000
- -
- —ROW--�--ROW-----ROW—�—
�SIia61W--- —ROW-----ROW----
0
O
\
- — — — — — —
+
-r
V /
low
--S1
W
ASPHALT
1--5—
Ld
--S-----5--�
—S '4-Io--
----5--
z
I
h�
1 1
I I
�
I
III
I
Q
PRO�OSED STREAM
CRO SING PER SMALL
'I
'
STREAM CROSSING DETAIL
I I
I
A
S&S CONSTRUCTION
►O 1
I
& RENTAL
I
SANDEL CORPORATION , ANTHONY M CIACCIA ETUX
I
PIN# 8751-77-7333.000 ,
PIN# 8751-78-2168.000 DANISE M CIACCIA ETAL
' Z I�
PARCEL 16178 '
I
PARCEL 15704 I PIN# 8751-77-6304.000
inIII
I
PARCEL 61429
1
11 q 1
I
�I
1
1 '
NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS FOLLOWS.
SEE EROSION CONTROL DETAILS FOR INSTALLATION AND MAINTENANCE REQUIREMENTS.
LOCATION LINING TYPE MINIMUM WATTLE SPACING
256+00 TO 259+50 NAG S75 MATTING OR EQUAL 30' 0. C.
260+00 TO 266+50 NAG S75 MATTING OR EQUAL 30' 0. C.
3' MIN. (COVER. TYP.
..c
655
635
630
625
620
257+00 258+00 259+00 260+00 261 +00 262+00 263+00 264+00 265+00 266+00 267+00 268+00 269+00 270+00 271 00
DocuSigned by:
50 0 25 50 100 SHEET
NN'CA'R'��,,,, ,�gEFORF CHATHAM-RANDOLPH MEGASITE
5274Q2 �Cg66MsS/°OO`/�/ %V
.6F OyOG
5 Regional Circle oti°°� ; Q� oc SEWER SYSTEM EXTENSION GRAPHIC SCALE DIVISION VALUE = 50 FEET PLAN AND PROFILE FORCEMAIN
Suite A =°Q� 9� ��
o SEAL = STA. 256+50 TO STA. 271 +00
Pinehurst, NC 28374 = a o0 034999 o , TOWN OF SILER CITYOFFICE MANAGER DESIGNER
910.295.3159 ; -v °�
' Z_%F E`�°°J ' N'9 �� 2 5 9 23 DLH NCDOT COMMENTS D. HONEYCUTT D. HONEYCUTT C=1 18
/ °°°°GINS°° G
NC Firm License # C-0459 - O �' �'
/C9 /�;_Hoo- ��\\\ ���GGING PP1 03/14/23 DLH NCDMLR COMMENTS CHATHAM COUNTY, NORTH CAROLINA PROJECT MANAGER REVIEWER DATE PROJECT# FUNDING#
mcgillassociates.com 5/25/2023 1 NO. DATE BY DESCRIPTION D. HONEYCUTT DECEMBER 2022 13.04039 N/A
co
0
0
co
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
� � 1
1
� \ 1
� 1
\ ` I
1
\ 1
—
� I
SMU RENTAL PROPERTIES &
\ \ INVESTMENTS, LLC
PIN # 8751-87-0578.000
` BROOKDALE BAPTIST CHURCH \ PARCEL 83904
ASSETS WEST LL\ & \
OVIDE TAM & MIRIAM\DE PIN# 8751-77-9641.000 �\
ST AUBIN \ PARCEL 83905 \
VPIN# 8751-78-4932.000
PARCEL 15712 `
\ I
\ _ - " " _ _ ROW= W�
655
650
645
635
630
625
620
615
PROPO
2— 8" BENDS--��
A - 7A-7 02a.2�
/
sue,\
\ - 633 I1 I h \
�01\52a3 \/ '� O0 OSED 20' P RMANENT EASEMENT
�34.40
O
11 0 r W- 5
_ _
'RWW 64j\ US K FM �� _ PROP SED 10' TEMPORARY EASEMENT \�/ 'DUKEX ERGY PROGRESS, LLC
l�— E OL S g�1p'7 _ ,�-� _ _ — / `61 / F �` PIN 875IX7-1019.000
SANDRA PATE BELL. \ �_ ♦ 61�F P EL80164
PIN# 8751-87-8346.000
PARCEL 79778
SANDRA PATE BELL� ♦
\ZL
— ���E— / / - _ , — —6 § 15 \ PIN# 8751-87-6345.000 _ - \ ,�4 xGJO
o _ _ Row — _ _-- PROPOSED 18" C905—DR 21 PARCEL 79777 , _ / \ \ ♦ �00
ow = —5—� PVC FORCE MAIN /-'� \ `P.•
. COVER, TYP.) 1�IN# 8751-87-5088.000%
,ro — — — S PARCEL 16166
PROPOSED AIR VACUUM REL F-
TEMPORARY RIPRAP OUTLET / J�
v� - --4w o PROTECTION, TYPICAL VALVE (AT ACTUAL -FUG - OINT) PROPOSED EROSION CONTROL
FM r" —___s m am \ EXISTING 8" FORCE MAIN SANDRA PATE BELL `, �''� MATTING WITH SEEDING,
PIN# 8751-87-2395.000
a a
m NS m \ \ PARCEL 79776
►U— a PROPOSED ASPHALT DRIVE
REPAIR PER DE IL PROPOSED FORCE MAIN AT SM"��
BROOKDALE BAPTIST \, LOCATION AS SHOWN SHALL 20
CHURCH, TRUS BE A MINIMUM 5 FROM -'
\ PIN# 8751-87-0372.000 \ EXISTING CULVERT
272+00
5 Regional Circle
Suite A
Pinehurst, NC 28374
910.295.3159
NC Firm License # C-0459
mcgillassociates.co
m
273+00 274+00
DocuSigned by:
5274(ZFC, 6� 4. P � ` /''/i
0o FESs/o
SEAL =
O o0 034999 o
0000000000
5/25/2023
�\ PLAN \ \
� \ � DENICE 0 EDWARDS
v \
� \ � PIN # 8751-87-7615.000 �
PARCEL 16106 \` \
PROPOSED 18" PLU\VALVE
`\ `\ HUEZO ARTURO \ W/VALV5\ BOX
ARMANDO PERAZA `
PIN# 8751-87-5690.000
\ \ PARCEL 16105 `� O
0�� %
BETTY DUNN MCKINNEY
TEMPORARY RIPRAP CH`ECK PIN# 8751-87-4670.000
DAM PER DETAIL, TYPICA\ PARCEL1620z `\ k
JAMES DOUGLAS ELLIS
& LINDA A ELLIS 00 Rowi�W
PIN# 8751-87-3549.000 \ \ ur �� jsR
PARCEL 16103
,�000LAS ELLIS \ 00 ��W BROW /� �sR�
\ ' PIN# 8751-87-2528.000 �\ �� iR� R�� I �64/ /
1 PARCEL 66405 643
275+00
�EF0RFy0
Q
2 5/9/23 DLH
GING PP 1 03/14/23 DLH
NO. DATE BY
276+00
277+00
NCDOT COMMENTS
NCDMLR COMMENTS
DESCRIPTION
278+00 279+00 280+00 281 +00
CHATHAM-RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
TOWN OF SILER CITY
CHATHAM COUNTY, NORTH CAROLINA
0
615 1 595 1 1 595
282+00
283+00
50 0 25 50 100
GRAPHIC SCALE DIVISION VALUE = 50 FEET
OFFICE MANAGER
D. HONEYCUTT
DESIGNER
D. HONEYCUTT
PROJECT MANAGER
D. HONEYCUTT
REVIEWER
284+00 2841+50
PLAN AND PROFILE FORCEMAIN
STA. 271 +00 TO STA. 284+50
DATE
DECEMBER 2022
PROJECT # FUNDING #
13.04039 N/A
SHEET
C=1 19
co
O
0
co
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
b
PLAN
S /
\`\
II
/ I __--- �-- II
' S-I
DIANA TAPIA 1
PIN# 8761-06-2833.000
REYES DANIEL MORALES ETUX
PARCEL 16142
'
\ \\ 1
AMALIA GONZALEZ MORALES II
/ '� I
�
PROPOSED BORE PIT S�
Q i"" ��� ,
PIN# 8761-06-0875.000
CAROL S MOODY ,1 PARCEL 16163 III
w '1
�P
, ,,�of
i�
LUJAN MANUEL ETUXI PIN# 8751-96-9970.000
AN
ALICIA ROMO '� PARCEL 16158 I
I O
/
/ j I I OCPT�O R� �� ��
— \ \ \� P
\ PEE sPN PROPOSED 40 LF 36 x 0.375 WALL
THICKNESS �
� P I N # 8751 96 9819.000 I '�
o
W + � O
N
x
�;\ •,ti �`' �° \PPPRO�oMW�EPS�pON STEEL ENCASEMENT PIPE, BORED AND JACKED WITH ` G HELEN MANESS
\ 20 EWE P 3$ » g5
g51�
I PARCEL , O
, O
A O +
0
N O
PG
20021 18 CLASS 250 DIP CARRIER PIPE
PN��68 �9�a' PIN# 8751-96-8946.000
\ N'• 59� 1
2
, +
' I 1
P�
%♦
♦
i\ v♦
\.�
, 1 E� 6�5 PARCEL 16164
VENTURA-MORALES ASCENCION \ 1
O)
I 1
I z Row
`l' \ ♦, .
\\
- \\
1
ETUX MARIA ELENA ORELLANO ,
+
1 r I 16
,
---- / 64
v —ROW s
/ E'er?�►
\ \
6, �s TEMPORARY SILT FENCErn
PER DETAIL, TYPICAL
TEMPORARY PIPE INL T PIN# 8751-96-69s6.000
O ot,Pf
1 1� 85.3�
+ I N N1�b 1 a�
E--��
---------
v �� INS �w
-
♦
PROTECTION, TYPICA 1
PARCEL 16159 O
ow % ��
to 1 z - i �/ / v
I rn - -N
0*1
s—�= _
rn W Uj
—
:, -� o \ PROPOSED 18 CLASS 250
1 4_
W�
- l- ow —I— �_
_
\�
(6)X s DIP FORCE MAIN
_�- ,+f,
`� O \ vl �'
J _�
- o
i �'- 2'\6'4 N7 �
LL
___- U
\
\\ \ _ -
-�'"L-0 OCELOT OSTOS N
MARIA RAMIREZ MEDINA 11
-{- W — of —�]�
rn ��
!�,_ ��—
---
- _ - ya�J a
— �3P `cwa ~
� I-
PROPOSED ROSION \\ t \ (3 MIN. COVER, TYP.) -
_
� `` �
6'
—�FM _---�
'+ _ _===
-- __��
_ _=
PIN# 8751-96-5902.000\�7 s --- �� — � ���
N
`�`' \
CONTROL TTING
2 ' \ \ _ -B7�ZI L PATTERSON 8" PVC 6M�
F�� —_ -s
�`� - z
PARCELs1191 G
10 a� f M
O I \ S,GP1
coNCRE R s= oWti
s_ =- —R'' _ --R
B¢4. — W — 1
` ,
WITH E D I N G pF
/ . _ _
\\ — — g^PVC _ PIN 8751-96-3943.000 s
# \
2
Pr1G16g61 61
f O N 5g58 _ -ice _ W�
GZ\P p1 + �' 18 31 f- �O W I —645
8a01 EL'6
_ a
- -
W >
ROw I
�
\\
S-
�� , 1
v� PARCEL 81239 �:0169A3
8� N
N
— '
EEG -� i-a��Dd-O
6 F — ,'� _ �" /' // °-" �-°' _ -�0
Cb'% / / RO
__ 1� 1169 226 81 O P \
0 65. 60 N RET�
— TEN PORARY INLET
Owe
— I PROTECTION TYPICAL
>•
1
.( CAI^ 1^
S \
/ / / 185 85 2
/--�- 61 °' 1�. 16B 1
0ti 0 \ L N E 1859391�
628
_
- ,
i R —
�"_ - (_ -• v 1
U 1 1
,
I
\
PROPOSED ONE FULL
/ _
614 / / �% ,�.
\- rF� - / / /' / - c�\c SIDEWALK i y
\ __61% � / / /—yr ♦ �
_/
�- -`° _ � 1 ,
_ ► ROW cWM
628 co _ 3' — — Z 1
ABLE - o I
—��W \ �� w— U
o�IP�o I 1 I
3.
1 3I�16� g26 5 1
1 N'• 5g
E'•1g3990 1 I 1
SANE WIDTH ASPHALT
ROAD REPAIR PER DETAIL
_
\
-66 9-' '/'moo \ �- °=
_ —
�— _ D -- 1
_aDL_ NM 1 1
"
OZIP20 I �` PROPOSED 18 CLAS
3I �
5
6� _—
k/ F _623 —�SMh- —
� 62 /--FM
— 0 PE 1 ' I
c �o- 6�1' 6
I
'
1g1�3�
N? 1g5 95 250' DIP FORCE MAINI
(3 IN. COVER, TYP.�
1 _/-
625 '``' '/'/o �-W- - _ __ -- - Q /
-621\-626- -1 �- ° a o
-�_ °�
1
PROPOSED
PROPOSED AI /VACUUM RE IEF A-
_ , >� - 36--- , I
SANDRA PATE BELL. i -6 62s- - � ��-f�' - 1 '
/ ,
/j I
I VALVE (AT A TUAL HIGH PO NT) �
I
-
/'
PIN#
/ - 636--
8751-87-5088.000
\
o I
1
I BORE
AND JACK NOTES:
— 631 , oo —s4o BAZEL PATTER �\ \�__- 1 , 1 I TEMPORARY RI�RAP
PARCEL 16166 9_ _ _ s4i�
' DAM PER DETAIL,
CHECK 1 \ 1.
TYPICAL '
BOTTOM OF BORE PIT SHALL BE MINIMUM 1' H. 1' V. THEORETICAL
PIN# 8751-96-3834.000
-642- .
TEMPORARY SEDIMENT TRAP #2 y // / -6k°�` ��— --643- PARCEL81240
_ _ I �\
I
I _
'1 I 2.
SLOPE FROM EDGE OF PAVEMENT OR ACTIVE SHORING MUST BE USED.
SPOILS PILE SHALL BE PLACED ADJACENT TO BORE PIT WHERE ROOM
'/ / / i' i - 644-
- 645 \` / O�IPf1 '
_ 66�61 / / / / / /' 646- 1�2116g3a5 60
N of N� — k— \ 1a5 6,
/ /
0�1P98 '
1� Tg59h38 95 I ' ', I
E'.. 31. 1 I
6
--/-
1/
-/ EXISTS WITHIN ROAD RIGHT—OF—WAY OR SEWER EASEMENT. SILT
' - /
�' FENCE SHALL BE INSTALLED AND MAINTAINED ON THE DOWNHILL SIDE
6� 0 / S _647- E. 6g0.
6 N� �'\�1
' '1 PROPOSED O�EN, CUT AND
1 /-'
OF THE SPOIL BORE PIT AND SPOIL PILE. CONTRACTOR SHALL PLACE
PROXY OE P� -- i66p0 / F �,
��--_
PFoo�og g3p2'PG " 60 / / / '
Z o Zo k2 / / /
I I
I I PATCH EXISTING PAVEMENT 1
/ -
_
-
SPOILS IN DUMP TRUCK OR STORE IN OTHER LOCATION WITHIN
66�3dbyo �_�� _
`�
\ , 1 ' /--
DISTURBED AREA IF ADEQUATE SPACE IS NOT AVAILABLE.
,',,—_s _
I I TEMPOR'�RY INLET
3.
CONTRACTOR SHALL NOTIFY ENGINEER IF ROCK OR OTHER UTILITIES
�_�a
PROTECTION ,-/�
ARE FOUND WITHIN THE BORE AREA PRIOR TO BEGINNING BORE AND
JACK. WHERE CONDITIONS DO NOT ALLOW BORE ENGINEER MAY
PROPOSED `- — _` 6 �
665' ' — \NOTE:
LATIONS OF EZiBG-l�'f�ITIES AS SHQWN ARE APPROXIMATE ONLY.
'"
COORDINATE WITH NCDOT TO REQUEST OPEN CUT OF ROADWAY.
—��'
2-18 45 BENDS — i /// / s
"
. 651 ,-_
1
EXACT OCATIONS A�E VERIFIED IN THE Fy LD BY THE CONTRACTOR.
_/
—5—
64
640
640
660
PROFILE NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS FOLLOWS.
660
2' MIN.
SCALE: HORIZ. 1"= 50' SEE EROSION
CONTROL DETAILS FOR INSTALLATION AND MAINTENANCE REQUIREMENTS.
CLEARANCE
VERT. 1"= 1' LOCATION
LINING TYPE MINIMUM WATTLE SPACING
635
655
635
655
286+75
TO 288+25 NAG S125 MATTING OR EQUAL 20' O.C.
EXISTING
GROUND
\
630
650
650
6"w1 630
PROPOSED AIR VACUUM RELIEF
i
VALVE
(AT ACTUAL HIGH POINT)
i
r
PROPOSED
18" CLASS
/
625
645
i--
250 DIP F
RCE MAIN
625
645
(3' MIN. C
VER, TYP.)
/
N
620
640
EXISTING
GROUND
620
/
640
i
2'
MIN.
615
615
635
i
635
__---
i
�—
10
610
��
630
12-RCP
605
605
625
12"CMP
x
625
PROPOSED
40 LF 36"0
x 0.375"
2
WALL
THICKNESS STEEL
\
ENCASEMENT
PIPE, BO
ED AND
8"IDIR
SEWER 0
2y MIN.
JACKED
WITH 18" CLASS
250 DIP
CLEARANCE
620
600
600
620
CARRIER
PIPE
2 MIN.
CLEARANCE
PR
POSED PVC TO DIP IRANSITION
595
615
595
615
285+00
286+00 287+00 288+00 289+00 290+00
291 +00 292+00 293+00 294+00
295+00 296+00 297+00
298+00 299+00 300
00
5 Regional Circle
DocuSigned by:
c,,.44� 'R'',,
s274C CfiAB�J 4® °°°OOo �/ ,
o0 oF�Ss�0' °-o ;
,�eEF0
YO
�'o�
CHATHAM-RANDOLPH
SEWER SYSTEM
MEGASITE
EXTENSION
50 0 25 50 100
PLAN AND PROFILE FORCEMAIN
SHEET
Suite A
°Q� oo SEAL 9� °�
Qom`'
, C
GRAPHIC SCALE DIVISION VALUE = 50 FEET
STA. 284+50 TO STA. 300+00
Pinehurst, NC 28374
= a o0 034999 o
°�
, o
TOWN OF SILER
CITYOFFICE
20
MANAGER
DESIGNER
910.295.3159
NC Firm License # C-0459
= v °
':�i°��ciC=1
NE-oo°°°J)
-, O ° �,
N
��
F
D. HONEYCUTT
D. HONEYCUTT
2
5/9/23
DLH
NCDOT COMMENTS
1
03/14/23
DLH
NCDMLR COMMENTS
CHATHAM COUNTY, NORTH
CAROLINA
PROJECT MANAGER
REVIEWER
DATE
PROJECT#
FUNDING#
mcgillassociates.com
��'�'�;°HON0�.``�/GGING
'''1110 �``�
QP�
NO.
DATE
BY
DESCRIPTION
5/25/2023
D. HONEYCUTT
DECEMBER 2022
13.04039
N/A
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
SILER CITY PARK
PIN # 8761-06-6649.000
PARCEL 62689
PROPOSED 2-18" PROPOSED BORE PIT
45' BENDS o
row
i �W�
FERNAND LRTEZ MALDON)�DO & 3 c, tis' 18 �MOZ_ � / - _
RNESTINA ANTON
N # 8761-06-4729.000
PARCEL 16141 �\� — — — - �� 41021
61
--------�, 3010�\� j „' `615 PROPOSED 60 LF 36"0 x 0.37 — �M° , S
/1 /616/ / ; WALL THICKNESS STEEL / / '�—
BORED AND / f� „� '�'�b� / ENCASEMENT PIPE,
WILLIAM L STOVA \ NN7> N I
BRENDA C/ DERRICK LEE „617 � , JACKED WITH 18" CLASS 250 DIP
� BRENLE
STOVALL/ TODD STOVALL o i 61s JAMES M GOINS CARRIER PIPE /
\\ PIN# 8761-06-3832.000 �I � / St PIN# 8761-06-3682.0�0 2 '
PARCEL 16139 / r /
s>y � PARCEL 16161 v, r
' ARY SLT FENCE W DOLPHIN INVESTMENTS, LLC
/ TEMPOR
s�0 � n ` � � � PIN# 8751-96-8511.000 /
�€R�ETAIL, YPICAL PARCEL 16173
rr '
Cy�INF S r PROPOSED 18" CLASS
�'�• 3 250 DI FORCE MAIN
r
00�`Op (3' MIN. COVER, TYP.)
r ,
r
i
PLAN
,
FIRST UNITED METHODIST
CHURCH TRUSTEES
o/ /N
PROPOSED ASPHALT ROAD \, EXISTS WITHIN ROAD RIGHT—OF—WAY OR SEWER EASEMENT. SILT
REPAIR PER DETAIL PIN# 8761-05-6714.000 FENCE SHALL BE INSTALLED AND MAINTAINED ON THE DOWNHILL SIDE
PARCEL73037 OF THE SPOIL BORE PIT AND SPOIL PILE. CONTRACTOR SHALL PLACE
SPOILS IN DUMP TRUCK OR STORE IN OTHER LOCATION WITHIN
DISTURBED AREA IF ADEQUATE SPACE IS NOT AVAILABLE.
O — _ 3. CONTRACTOR SHALL NOTIFY ENGINEER IF ROCK OR OTHER UTILITIES
00 S ARE FOUND WITHIN THE BORE AREA PRIOR TO BEGINNING BORE AND
'� S+ JACK. WHERE CONDITIONS DO NOT ALLOW BORE, ENGINEER MAY
, COORDINATE WITH NCDOT TO REQUEST OPEN CUT OF ROADWAY.
1 IN -
PIN
61)
BORE AND JACK NOTES:
1. BOTTOM OF BORE PIT SHALL BE MINIMUM 1' H. : 1' V. THEORETICAL
SLOPE FROM EDGE OF PAVEMENT OR ACTIVE SHORING MUST BE USED.
2. SPOILS PILE SHALL BE PLACED ADJACENT TO BORE PIT WHERE ROOM
— —e\
_
O
'
S
CONTRACTOR TO CONFIRM
LOCATION OF
\ \W�
_W—
_
M
�� EXISTING WATER LINE, MAINTAIN
MINIMUM
10'
HORIZONTAL SEPARATION
OR 18" VERTICAL
0-- ;; _; ��W
— — ��
�5� SEPARATION WHERE HORIZONTAL SEPARATION
_
W RALE'GH T_,
�
_
,— �v-
,^
O CANNOT BE ACHIEVED
W
�l —CID
3N,
C)
°
EX. STREAM
L0
_
--=
/
a
W DOLPHIN INVESTMENTS, LLC
`f/W
Mobs\ Wes\\\
PIN# 8751-96-8511.000
,
JAMES B EDWARDS /
r
PARCEL 16173
PIN# 8761-06-3170.000
/
\ �A10N/�` W\
_!`�
2
PARCEL 73136 / /
i
W�
� - �� HMO A
622----
I
W _
Q_
TODD J POREMBA ETUX
MEREDITH G POREMBA &
MARCIA J EAKIN ,
/
PIN # 8761-05-3973.000
NOTE:
LOCATIONS OF EXISTING UTILITIES GCS WN /ARE APPR
IMATE (YNLL EL 71737 /
EXACT
LO�ATIONS
ARE TO BE VERIFIED IN TH FIELD BY /THE
co
ONTRACTOR.
i
PROFILE
SCALE: HORIZ. 1 "= 50'
VERT. 1 "= 1'
NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS FOLLOWS.
SEE EROSION CONTROL DETAILS FOR INSTALLATION AND MAINTENANCE REQUIREMENTS.
LOCATION LINING TYPE MINIMUM WATTLE SPACING
303+00 TO 306+00 NAG S75 MATTING OR EQUAL 30' O.C.
635
635
630
630
EXISTING
GROUND
625
625
PR
POSED 6
LF 36 o
0.375
620���
WA
L THICKNESS
STEEL
ENCASEME14T
PIPE
BORED
AND JACKED
WITH 18'
CLASS
250 DP
CARRIER
PIPE
4s
N,
615
— —
i
—��
6"VCIP
WATER �
610 +
24"RCP
��,_
I;
n
18"RCP
I
PRO
250
(3'
OSED 18 CLASS
DIP FORCE MAIN
IN. COVER, TYP.)II
�
CLEARANCE
24"RCP
u �
610
.-.My:
605
.�e
1 595 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 595 1
301 +00
302+00
5 Regional Circle
Suite A
Pinehurst, NC 28374
910.295.3159
NC Firm License # C-0459
mcgillassociates.com
303+00
nuSigned by:
CAR
!74010 o�Q°..SS�O°O�/i/.
z: ooSEAL =
Q 1. 034999 o
o�
-7 oo�000 GI NE��oooCJ
000000000
5/2'1
304+00
2 5/9/23 DLH
1 03/14/23 DLH
NO. DATE BY
305+00
306+00
NCDOT COMMENTS
NCDMLR COMMENTS
DESCRIPTION
307+00 308+00 309+00 310+00
CHATHAM-RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
TOWN OF SILER CITY
CHATHAM COUNTY, NORTH CAROLINA
311 +00
312+00
50 0 25 50 100
GRAPHIC SCALE DIVISION VALUE = 50 FEET
OFFICE MANAGER
D. HONEYCUTT
DESIGNER
D. HONEYCUTT
PROJECT MANAGER
D. HONEYCUTT
REVIEWER
.
313+00
314+00
31
PLAN AND PROFILE FORCEMAIN
STA. 300+00 TO STA. 314+50
DATE
DECEMBER 2022
PROJECT # FUNDING #
13.04039 N/A
SHEET
C=121
Q
z
O
Q
U
_
O
z
z
D
O
U
Q
Q
U
U
w
J
J)
w
O
z
O
Z
O
U)
z
w
i-
x
w
w
U)
U)
Cf
w
w
U)
rn
co
0
0
co
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
Ile
I
PLAN
I
i
I
I
SILER CITY CHURCH
I
I
„
PROPOSED 18 CLASS 250
, OF CHRIST
PIN# 8761-04-6798.000
I WILLIAM L PEAVEY JR.
1 & PAMELA W
,
Al
DIP FORCE MAIN `"
0
/ PARCEL 62729
I PIN# 8761-04-6458
I JEAN W PINKSTON ETUXI
(3' MIN. COVER, TYP.) _ — — Z
s
'
I PARCEL 14954
CHARLES ROBERT LORETT DIAB WHITEHE AD
I I A W BATCHELOR
CONTRACTOR TO CONFIRM LOCATION OF
s--
PROPOSED STREAM CROSSING
I
I PIN# 8761-04-5363 I BARBARA W TOWNSEND
EXISTING WATER LINE, MAINTAIN MINIMUM 10'
_ _s--PROPOSED FORCE MAIN AT
PER SMALL STREAM
I PARCEL 17228 I PIN# 8761-04-9216
HORIZONTAL SEPARATION OR 18" VERTICALs
_
-- _s LOCATION AS SHOWN SHALL BE A
CROSSING DETAIL
PARCEL61506
SEPARATION WHERE HORIZONTAL SEPARATION
MINIMUM 5 FROM EXISTING CULVERT
I TEMPORARY RIPRAP CHECK I
BE ACHIEVED
%
� DAM PER DETAIL, TYPICAL
--_s---CANNdT
PROPOSED REPLACE EXISTING
TEMPORARY WATTLES
TEMPORARY INLET
PROPOSED 4-18"
RIPRAP AT PIPE OUTLET
PER DETAIL
PI OTECTION, TYPICAL
1
, 45 BENDS
_s
0
0 0
o
0 0 ;+
0
+ +
0 0
+ I +
,
I I
+
p +
�_
000 0 / M
M n
N +
+
0
In M
M i
I g N
O I
I
+
I
+ I
m
MATCH I E STA. 329+0
Q
_�
�� ���� _ �-
_� — _ \ _
18
_
STAKE OUND
—'mil
Z
625 , 626 627 W RALEIGH ST
< I I \ s
, \ / -
` / /
/
�' /
623
,624
\
\ S.R.1006
U--
--<s-----s—
— — _�—�-----=_828--
Wes— —w-- —
w u \ 9 0 -33, __ u �3 6—_ \
\ --- ��s s�� — --_
\ R,�
\ iVA GH
�._ —w----mow—
-- —T —Moa--
--- _ 9 -- -- —
—Moa----=6m —Z -- _
---nnoa---- -----
S=�eo�j- ��� `\ 3
\
— 1 a S �
p
----Moa-----Moa---
nnc l-----nnoa---- __
_
5� a� s--,—Moa
6110 \sR \ 6\0-5. W� 1:�
PROPOSED
TRANSITION TO 18"
PROPOSED ASPHALT DRIVE
1
'
C905—DR
21 PVC FORCE MAIN
1 REPAIR PER DETAIL
I I I
�� /
��� /
\ �_ �\ \ \ o �� �J° �e
f
(3 MIN. COVER.
TYP.)
I
I I FTI
I I
1
1
I ,
1
I
I a
PROPOSED GRAV L DRIVE ���
► d
I
REPAIR PER DETAIL ww I
I
PROPOSED GRAVEL DRIVE / `Mo \ \
LAKEV OD MANOR HOMEOWNERS
1
1ASSOCIATION, INC ,
I
EPAIR
PER DETAIL
SIN
I
TEMPORARY PIPE INLET
8761-05-2223.000
PARCEL 16221
PROTECTION, I TYPICAL
/
L—L—L I
I __—__—__ I I I
-I I
i I I
PROPO ED 18" PLUG
VALVE /'W VALVE BOX
/
I ,
_ _ —w I�
I I
/
�
� PROPOSED ASPHALT
/
REPAIR PER DETAIL
I
I
-----�
I NOTE. LOCATIONS OF EXISTING UTILITIES A SHOWN ARE
A�jPROXIMATE ONLY.
'
EXACT LOCATIONS ARE TO BE VERIFIED IN ITHE FIELD BY
TWE CONTRACTOR/
__
660
660
PROFILE
PROPOSED
TRANSITION
TO 18"
NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN
DRAINAGE DITCH AS FOLLOWS.
C90
—DR 21 VC FORCE-
MAIN
SEE EROSION CONTROL DETAILS FOR INSTALLATION AND MAINTENANCE REQUIREMENTS.
SCALE: HORIZ. 1 "= 50'
f
VERT. 1 "= 1'
655
LOCATION LINING TYPE
MINIMUM WATTLE SPACING
655
321+00 TO 328+00 NAG S75 MATTING OR EQUAL
30' O.C.
PROPOSED 18"
PLUG
VALVE W/VALVE
BOX
_
I
J
650
I
650
/J
645
645
i
— J
I
1
640
`'
640
/
(( ) 1
"RCP
EXISTING
GROUND
635
635
�
12"RCP
/
2' MIN. CLEARANCE)
630
_
630
MIN. CLEARANCE
625
---
---
625
—PROPOSE-1)
--- —
18 CLASS 250
__
DIP FORE
MAIN
_.
-----
PO
3' MIN.
COVER TYP.)
620
—'
V /1
10"PVC
620
615
615
315+00
316+00 317+00
318+00 319+00 320+00
321 +00 322+00 323+00 324+00 325+00
326+00 327+00 328+00 329+00
5 Regional Circle
DocuSigned by:
4Q 'RO/,/,
\; o�oFES°si0, �-o ;
�,�,\gEFORF yo
�'o
CHATHAM-RANDOLPH
SEWER
MEGASITE
SYSTEM EXTENSION
50 25 50 100
PLAN AND PROFILE FORCEMAIN
SHEET
Suite A
°Q� o SEAL 9� °�
Qom`'
, C
GRAPHIC SCALE DIVISION VALUE = 50 FEET
STA. 314+50 TO STA.
329+00
Pinehurst, NC 28374
= a oo 034999 0
°�
Q o
TOWN
OF SILER CITYOFFICE
C=1
MANAGER
DESIGNER
910.295.3159
NC Firm License # C-0459
= -v e '
FN �`�°°J '
� / GINS° ° C, �\
-, O ° °°°°°°°° �
N
9,� ��
,�
D. HONEYCUTT
D. HONEYCUTT
2
5/9/23
DLH
NCDOT COMMENTS
1
03/14/23
DLH
NCDMLR COMMENTS
CHATHAM
COUNTY, NORTH CAROLINA
PROJECT MANAGER
REVIEWER
DATE
PROJECT#
FUNDING#
mcgillassociates.com
,�
�' H0N' ,
5�f'�Yr02T``
���GGING QQ�
NO.
DATE
BY
DESCRIPTION
D. HONEYCUTT
DECEMBER 2022
13.04039
N/A
2
D_
O
0
z
Q
Q
2
U
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
-
------—----—----—--—-- — -- -------------
-----------------------
I I I1 ,
1 _ I
JEAN W PINKSTON ETUX 1 PLAN
CHARLES ROBERT 1 1
HORTENCII TINOCO HERN�NDEZ
PIN# 8761-04-5363 I PIN Nq. 8761-14-44133
PARCEL 17228 PROPOSED 18" C905—DR 21 1 PARCEL 17208 ► I
PVC FORCE MAIN 1 1 I
(3' MIN. COVER, TYP.)---------------- I I
N
-------------------------------------------- ' I
---------------------------- MEDINA CESAR RAMIREZ I r
PROPOSED GRAVEL DRIVE WILBERT SPRUILL TRUSTEE VALENCIA HILDA RODGIGUEZ ► 1 PROPOSED 20 PERMANEN EASEMENT
PIN NO. 8761-14-11843 PIN NO. 8761-14-3127 I
REPAIR PER DETAIL PARCEL 17230 PARCEL 71260 SHIRLEY CLARK I EDGAR A MELGAR
DIANE B WHITEHEAD PIN NO. 8761-14-4157.000 PIN NO. 8761-14-5196.000
LORETTA W BATCHELOR '
PARCEL 17204 PARCEL 17200
I i
BARBARA W TOWNSEND 1 I I
/
PIN# 8761-04-9216
OQ PARCEL 61506 1
O 0 / J
00 + 0 00 0 0 I
0 + ± N I j + 0 , 0 0 0
0+ O IM 1O , j r`% L / 0 3/414053 88 + + 0 O O 0
+ to F.., 61223.17 00
V) M I o+ + 0
EL: 632.62 � , O + +
PO M � M
1) PO
—�—W—_ --W--- —W —W --- — — —I- i i--E-- — E E g E-- M I E FH ---- I------- E------ t E M
W -- --W—---W— ----W p---W---� v v v v— o rn -�- — o� u� — —W--- - _ �� -- -- -- --- ---- --- --- _ -_--- ---o� E
_ —II _ _ _ — _ 'rn N I N 0 Oj
W h� SUNVIEW�65.JE o �orl _ cz o 0 0 0 0/� Mo Mo mA 633 \\ W---- IIW-- ----- E _ \\\\ = // —-----W-- --W _63_633 _6,32� 6i�C�63 �6WV l�� l� 6�� N �E _^ h
FM���_ _ ��� ice_ ___7.i.- -r-- iN--i9 . N- r--�'-- 1-5 -= "�� - - - - -- 3�' y� —hy WV W— — — W— — — — — \ — �— — — — — — W— — `O — - W_
E
Z - ul �� �� ��i���������������������i�� / 7 �rt - I-- FyFb�{.Fy �y \ SU VIEW\DR \
W CONCRE E E I � I I � L
U E E E — - I I I---t--- -- __ __ __ _ ���
CC 1 I 33
' —
I PROPOSED EROSION CONTROL N.8611420
I 5/g" RBF
N:714102• 06
EL'.640.4
PROPOSED CONCRETE
DRIVE RIfPAIR PER DETAIL
PROPOSED IR/VACUUM RELIEF
VALVE (AT ACTUAL HIGH POINT)
1 �
CHUCK STIRES 1
PIN# 8761-04-5011.000
PARCEL 17232 1
I 1
I
I
1
I
665
PROPOSED AIR/VACUUM RELIEF
E:1Lij
EL:632.66
MATTING WITH SEEDING
z
z
.J
TEMPORARY RIPRAP OUTLET
U
PROTECTION, TYPICAL
PROPOSED TEMPORARY 10' EASEMENT
Q
HARRIS HANNAH LEE WILLOUGHBY
I
ETAL
1
PIN # 8761-03-8724.000
HARRIS HANNAH LEE WILLOUGHBY JERRY B WOOD III ETUX
PARCEL 14955
ETAL BETTY FRANKLIN
I
PIN# 8761-03-8724.000 PIN NO. 8761-23-4746
PARCEL 14983
I
PARCEL 14955 I
BERT RAYMOND & AMY R BREWER
PIN NO. 8761-13-4868
I
PARCEL 63013
I
I /
1
I
1
,
'
LOCATIONS OF EXISTING UTILITIES AS SH WIN AR APPROXIMATE ONLY.
INOTE:
EXACT LOCATIONS ARE TO BE VERIFIED IN THE IELD B THE ONTRACTOR.
—
665 1 645
NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES
IN DRAINAGE DITCH AS FOLLOWS.
PROFILE
SEE EROSION CONTROL
DETAILS FOR INSTALLATION AND
MAINTENANCE REQUIREMENTS.
SCALE: HORIZ. 1 "= 50'
LOCATION
LINING TYPE
MINIMUM WATTLE SPACING
VERT. 1 "= 1'
332+00 TO 335+00
NAG S75 MATTING OR EQUAL
20' O.C.
339+50 TO 351+00
NAG S150 MATTING OR EQUAL
25' O.C.
645
660
660
640
EXISTING
GROUND
640
655
EXISTING GROUND
655
635--
—`��
635
`
PROPOS
D 18" C905-DR 21
------
---
-
`
`
PVC FORCE
MAIN
650
630
630
(3MIN.
COVER, TYP.)
`
'
I
`
777
645
645
625
mft��_
N1�1
1
625
PROPOSED
18 C905—DR 21
�
`
PVC FORCE
MAIN
(3' MIN.
COVER, TYP.)
`
\
640
`
640
620
`�
620
635
` 11
635
615
615
630
610
630
610
605
605
625
625
330+00 331 +00 332+00
DocuSigned by:
5 Regional Circle 52; 0 o sio��i,P ;-
Suite A F\S,.000 Q�
SEAL —
Pinehurst, NC 28374 = a o° 034999 o
910.295.3159 ; -7000F
mcgill NC Firm License # C-0459 -,/O °0INV-o oo�C�
mcgillassociates.com 5/2523
�EF0
Q
O �
333+00
NO. I DATE I BY
334+00
335+00 336+00 337+00 338+00 339+00
CHATHAM-RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
DESCRIPTION
TOWN OF SILER CITY
CHATHAM COUNTY, NORTH CAROLINA
340+00
341 +00
50 0
25 50 100
GRAPHIC SCALE
DIVISION VALUE = 50 FEET
OFFICE MANAGER
DESIGNER
D. HONEYCUTT
D. HONEYCUTT
PROJECT MANAGER
REVIEWER
D. HONEYCUTT
.
342+00
343+00
50
PLAN AND PROFILE FORCEMAIN
STA. 329+00 TO STA. 343+50
DATE
DECEMBER 2022
PROJECT # FUNDING #
13.04039 N/A
SHEET
C=1 23
co
O
0
co
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
PLAN
MABRY HOLDINGS LLC
PIN NO. 8761-25-0094
PARCEL 17202
20' PERMANENT EASEMENT
0 0 o PROPOSED TEMPO
+ O DAM F
p � I + 0
0
+ I M I J J M/ _ 00
6i r6 ro 606 605 00k 60�b 602 Lo . / 00�1 /E —Cb ^ / - -
T� j/Wf/-/w /-�- i� ,�� h°j �5s6
Q W---W--- -'�N-- s��- \ 59�. \s90
I � \ W— — L — W—
/ a LJ6 E LINE/ /
1rREE INE L L G ��i / FM m i
LJLJJ
Z - -_ EE LINE
— —
PINE FOREST INC #1
PIN NO. 8761-24-6158.000
PARCEL 14984
Al
RY RIPRAP CHECK T PORARY SILT 1
DETAIL, TYPICFcricc Noires <
A--
c\W---1--I-W--THE �L E�� .
0 T
Q T
� J
m 10' TEMPORARY EASEMENT
PROPOSED
JERRY B WOOD III & BETTY FRANKLIN WOOD
PIN NO. 8761-13-8774
DID 815/PG 317
I PB 2000/PG 4
1 2" CTIPF
N/713701.05
E;1861758.85
ELI620.65
620
615
N,
605
580
N,
PROPOSED 18" C905—DR 21 1
PVC FORCE MAIN O
(3' MIN. COVER, TYP.) 0
o �
+
�— O
M
LO '� I rn �'y9ss_` + Z
e J
I ,
- - - W SB) TREE LINE
7 W— - - SB6 6 I n LIE
- W- - _ 5B
5�^- - N% - 0`i`..00 Oi�.�.. 0�'�i.i g� �.. FH I TREFN
�6 M
3RR 76" \ = - i - W - - 0 W o- j f ?- �69
FM = fy — - a THE LINE
F11FM 1
f=rt rf �—Fy FM —FM
N: 110
713714.62
_ E;1863129.46
TIPF I I EL;592.71
PROPOSED TREE LINE
0
O O O
O + O
--IPT-------- ---'—------- +
N:7137BT-700
EL 593..5 I 1
I
1 I 1
I 1
I
I I1
— JERRY B WOOD III ETUX I
BETTY FRANKLIN 1 I
PIN NO. 8761-23-4746 1
PARCEL 14983
� 1
\ 1 I
I
` I I
\ I
I I
\ I
` I 1
\ 1
NOTE: LOCATIONS OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE ONLY. �� I
EXACT LOCATIONS ARE TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR. \ I
� I I
PROFILE NOTE: INSTALL TEMPORARY DITCH LINING AND WATTLES IN DRAINAGE DITCH AS FOLLOWS.
SCALE: HORIZ. 1 "= 50' SEE EROSION CONTROL DETAILS FOR INSTALLATION AND MAINTENANCE REQUIREMENTS.
VERT. 1 "= 1' LOCATION LINING TYPE MINIMUM WATTLE SPACING
355+50 TO 365+00 NAG S75 MATTING OR EQUAL 30' O.C.
620
615
610
605
580
344+00 345+00 346+00 347+00 348+00 349+00 350+00 351 +00 352+00 353+00 354+00 355+00 356+00 357+00 358 00
DocuSigned by:
50 0 25 50 100 SHEET
ICAIIII�� >\B F CHATHAM-RANDOLPH MEGASITE
L \ NN `o,, EFOR Y,"
5 Regional Circle =o�oF oti9 �;; �Q� oc SEWER SYSTEM EXTENSION GRAPHIC SCALE DIVISION VALUE = 50 FEET PLAN AND PROFILE FORCEMAIN
Suite A = o =
o SEAL STA. 343+50 TO STA. 358+00
Pinehurst, NC 28374 = a o0 034999 o , TOWN OF SILER CITYOFFICE MANAGER DESIGNER
910.295.3159 ; -v F
-Z- M I `f' D. HONEYCUTT D. HONEYCUTT C=1 24
NC Firm License # C-0459 �',�/O°°��!N��°�GJ�'\ 9�F � ��'�
���//, HON���.`` ��GGING QP� 1 03/14/23 DLH NCDMLR COMMENTS CHATHAM COUNTY, NORTH CAROLINA PROJECT MANAGER REVIEWER DATE PROJECT# FUNDING#
C9 mcgillassociates.com 11111123 NO. DATE BY DESCRIPTION D. HONEYCUTT DECEMBER 2022 13.04039 N/A
5/25/2023
rn
co
O
O
co
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
c�
0
co
LO
b
PLAN
RAILROAD CROSSING NOTES:
1. CONTRACTOR SHALL FOLLOW ALL REQUIREMENTS
OF NORFOLK SOUTHERN'S NSCE-8
SPECIFICATIONS.
2. PIPELINE CROSSING TO BE INSTALLED AND
MAINTAINED IN ACCORDANCE WITH
LAST APPROVED
"AMERICAN RAILWAY ENGINEERING
AND
MAINTENANCE OF WAY ASSOCIATION"
SPECIFICATIONS FOR PIPELINES CONVEYING
NOTE: LOCATIONS
OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE
FLAMMABLE AND NON—FLAMMABLE
SUBSTANCES.
oq
�G
°
EXACT LOCATIONS
ARE TO BE VERIFIED IN THE
FIELD BY THE CONTRACT
PROPOSED TREE LINE
3. BLASTING NOT PERMITTED.
FFtir"�
ss
/00"1
�
I
V&D LAND, LLC
PIN N0. 8761-34-3261.000
I
PARCEL 17186
�Q.•
o
EXISTING NORFOLK SOUTHERN
RAILROAD TRACK
0
0
0
PROPOSED 18" C905—DR 21
PVC FORCE MAIN
PROPOSED PVC TO
DIP TRANSITION
100 R/,W
V&D LAND, LLC
PIN N0. 8761-3851.000
q>�,
(3' MIN. COVER, TYP.)
PARCEL 16436438
o
^I
Iv
�"oo
PROPOSED
�5X
sesoeoo
o
LAUNCHING PIT
��
`s6s�9�sFr
/
A
TEMPORARY SILT FENCE
\
PROPOSED 18" PLUG
o� PER DETAIL, TYPICAL
♦�
o VALVE W/VALVE BOX
;
�► /
x
s
10' O
ticy"
i/��
PROPOSED 18" CLASS 250
� �
-�
o
�s��3To
r a�
Fti��"
<•Sss3�,cA DIP FORCE MAIN
�1
PROPOSED 10' TEMPORARY EASEMENT
M
-
(3' MIN. COVER TYP.)
+�
TR
+
PROPOSED
T/?E ��E _
I
2-18" 45° BENDS �♦
PROPOSED
F,
,_
9 s
BORE AND JACK NOTES: �S
° —
FF" "� ���—` __
�s�' '--__-
�`�� `���� ��� ��mm
�, RECEIVING
0
kPIT 000
1. BOTTOM OF BORE PIT SHALL BE MINIMUM 1' H. 1' V. THEORETICAL
;T
_
FM
00
SLOPE FROM EDGE OF PAVEMENT OR ACTIVE SHORING MUST BE USED.
2. SPOILS PILE SHALL BE PLACED ADJACENT TO BORE PIT WHERE ROOM
EXISTS WITHIN ROAD RIGHT—OF—WAY OR SEWER EASEMENT. SILT
FF;�"� — — — — — — — _ _ _
■
�� 0-0
FENCE SHALL BE INSTALLED AND MAINTAINED ON THE DOWNHILL SIDE
s�s�
367+00
■ �/
I■
OF THE SPOIL BORE PIT AND SPOIL PILE. CONTRACTOR SHALL PLACE
i �j��
SPOILS IN DUMP TRUCK OR STORE IN OTHER LOCATION WITHIN
PROPOSED 110 LF 36"0 x 0.5" WALL
CP
DISTURBED AREA IF ADEQUATE SPACE IS NOT AVAILABLE.
THICKNESS STEEL ENCASEMENT PIPE,
1 2 o �►
3. CONTRACTOR SHALL NOTIFY ENGINEER IF ROCK OR OTHER UTILITIES
2
BORED AND JACKED WITH 18" CLASS
1 /�i 50'
ARE FOUND WITHIN THE BORE AREA PRIOR TO BEGINNING BORE AND
250 DIP CARRIER PIPET
EEC
WHERE CONDITIONS BORE, ENGINEER MAY
OPOSED
G
OORDI ATEWITHNCDOT TO REQU ST OPEN CUT OF ROADWAY.
��
2-18 450
BENDS
605
605
595
595
PROFILE
SCALE: HORIZ. 1 "= 50'
VERT. 1 "= 1'
600
600
590
590
595
595
585
585
590
580
590
580
EXISTING
GROUND
PROPOSED
1
PLUG
VALVE
W./VAL.VE
BOX
PROPOSE
18 C90
—DR 21
��,__
PVC FOR
E MAIN
585
575
(3' MIN.
OVER T
585
575
Q
PROPOSE
18" CLASS
250
Q
DIP FORC
MAIN
580
580
-57,0
3 MIN.
COVER, T
570
RAILROAD
THEORETICAL
2:1 EMBA
KMENT
Exls
NG GROUND
575
5
��
--
----
-----
--- --
------
--
------
565
575
i
560
570
570
560
' — — _
/
MI
3' CLEAR
PROPOS
D
565
565
555
RECEIVING
PIT
555
ROPOSEE)7
560
550
LAUNCHING
PIT-
-Ai
Nk
560
550
PROPOSED-
PVC
TO
X0.5
WAL
--
THI
KNESS ST
EL ENCAS
MENT PIP
,
BOR
D AND J
CKED WITH
18" CLAS
250
DIP CARRIER
PIPE
359+00 360+00 361+00 362+00 363+00
364+00 365+00
366+00
367+00 368+00 369+00
370+00
371+00 372+00
372
50
5 Regional Circle
DocuSigned by:
�AR',,
�` ` 00000, 0 ,
52\,o�ooF ss�U, ;
EFoR y
F
�G
Q`' o�
CHATHAM—RANDOLPH
SEWER
MEGASITE
SYSTEM EXTENSION
50 0 25
50 � oo
PLAN AND PROFILE FORCEMAIN
SHEET
Suite A
02� 9< o� '
= =
o SEAL 8
V , C
GRAPHIC SCALE DIVISION
VALUE = 50 FEET
STA.358+00 TO STA.
372+50
Pinehurst, NC 28374
= 0 034999 0 =
~
7
, o
OWN
OF SILER CITYD.
C=1 25
OFFICE MANAGER
DESIGNER
910.295.3159
NC Firm License # C-0459
°6 jo
/— °ENGINE -to -J)
-, O �000000o
9.� ��'�
HONEYCUTT
D. HONEYCUTT
2
5/9/23
DLH
NCDOT COMMENTS
y\ �,
�'�iC
F
mcgillassociates.com
HONE���
'�/�, „����`
��(�' QP�
GING
1
03 14 23
/ /
DLH
NCDMLR COMMENTS
CHATHAM
COUNTY, NORTH CAROLINA
PROJECT MANAGER
REVIEWER
DATE
PROJECT#
FUNDING#
NO.
DATE
BY
DESCRIPTION
5/25%�823
D. HONEYCUTT
DECEMBER
2022
13.04039
N/A
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
c�
0
co
LO
b
PLAN
PROPOSED 18" CLASS 250
RCE MAIN
(3' MIN. COVER, CROSSING o 0
UNDER 15 CM o
NO IMPACT O U +
O TRIBUTARY BORES 00
UNDER SYSTEM NO M
EDWARD N LILES �GZ O TR
PIN NO. 8761-44-3409.000 a ti O M IMPACT Q
PARCEL 65306 +
JAMES KEITH BOLING JR d- --
PIN NO. 8761-46-4060.000 O 00 UNNAM TRIBUTARY
ROPOSED 110 LF 30"O X 0.375" WALL PARCEL 16389 Z�� o I' fu
O � > Z Psi .. � �
�sao� e I� THICKNESS STEEL ENCASEMENT, BORED �< � — - "
AND JACKED WITH 18 CLASS 250
D.I.P. CARRIER PIPE Q o .TREE LINE
Q 2 O rn V �
XOO ^�� .a ��.�� -� `� d TREE LINE
4 1 PROPOSED BORE PITS >s
rn P:ba� O 00
o
♦ F �> F.• q O r EE LIN y'
r ♦ s�s�F �% <,.' s>A O M s�,
• s��o �o ss ���� + s� �= EE LINE s°so
Q� __ PROPOSED TEMPORARY SILT PROPOSED LF 30"' X 0.375" WALL THICKNESS
/ — _ _�, TREE LINE BORED AND JACKED WITH
`rams°� OVES EK _ 9 —�► FENCE, TYPICAL. STEEL ENCAS ENT,
18" CLASS 250 I.P. CARRIER PIPE
r GJ TREE LINE �- s6 trzl'F
s � BORE AND JACK NOTES:
-w PROPOSED WETLAND CROSSING, >
� PER DETAIL 1. BOTTOM OF BORE PIT SHALL BE MINIMUM 1 H. 1 V. THEORETICAL
> %1�y o PROPOSED 18 C905-DR 21 SLOPE FROM EDGE OF PAVEMENT OR ACTIVE SHORING MUST BE USED.
PROPOSED DIP TO PVC TRANSITION PVC FORCE MAIN 2. SPOILS PILE SHALL BE PLACED ADJACENT TO BORE PIT WHERE ROOM
(3' MIN. COVER, TYP.) 0 EXISTS WITHIN ROAD RIGHT-OF-WAY OR SEWER EASEMENT. SILT
FENCE SHALL BE INSTALLED AND MAINTAINED ON THE DOWNHILL SIDE
PROPOSED 50 LF 30"0 X 0.375" WALL
PROPOSED BORE UNDER STREAM, OF THE SPOIL BORE PIT AND SPOIL PILE. CONTRACTOR SHALL PLACE
THICKNESS �OLL.L NO IMPACT �sos, 'A' s NT, BORED 2 SPOILS IN DUMP TRUCK OR STORE IN OTHER LOCATION WITHIN
PROPOSED �� s AND JACKED WITH 18 CLASS DISTURBED AREA IF ADEQUATE SPACE IS NOT AVAILABLE.
2-18" 45° BENDS � D.I.P. CARRIER PIPE 3. CONTRACTOR SHALL NOTIFY ENGINEER IF ROCK OR OTHER UTILITIES
ARE FOUND WITHIN THE BORE AREA PRIOR TO BEGINNING BORE AND
JACK. WHERE CONDITIONS DO NOT ALLOW BORE, ENGINEER MAY
NOTE: LOCATIO OF EXISTING
EXACT LOCATIONS E TO BE
UTILITIES AS SHOWN ARE APPROXIMATE ONLY.
VERIFIED IN THE FIELD BY THE CONTRACTOR.
COORDINATE WITH NCDOT TO REQUEST OPEN CUT OF ROADWAY.
PROFILE
SCALE: HORIZ. 1 "= 50'
VERT. 1 "= 1'
580
580
575
575
PROPOS
D
18" CLASS
250
570
570
DIP FORCE
MAIN
PROPOSED
110 LF 301vo
X 0.37
r—EXISTING
WATER LINE
L
M
565
AND JACKED
—WITH 1
CLASS 250
565
D.I.P. CARRIER PIPE
2
OSED 18"'C905-DIR
E
_OfFO
EXISTING
GROUND
560
i-
560
I
�-
Wahl-,
555
I Ioe--
----
----- ---
---- ---
— ------
---_
555
CLEAR
NUN,
L-
8"PVC SEWS
550
550
PR
POSED DIP
TO PVC TRANSITION
2 -
CLEARAqCE
545
545
PROPOSED
50 LF 30 10.
X 0.375 01WALL
-EL E-NeASEM
—Bx'E)RED
'
AND
dAeKE)
WITH
THICKNESS
STEEL EN
ASEMENT,
BORED
2
is"' CLASS
250
DA.P.
CARRER
PIPE
540
540
D.I.P. CARRIER
PIPE
373+00 374+00
375+00 376+00
377+00 378+00 379+00
380+00 381 +00
382+00 383+00 384+00
385+00 386+00 387
00
5 Regional Circle
Suite A
Pinehurst, NC 28374
910.295.3159
NC Firm License # C-0459
mcgillassociates.com
DocuSigned by:
` VaR',,
A 0 ''%,
52; o�`°°�Fssio°°<� =
` =oQ�o ti9<�;-
- ° SEAL ° -
= 0 034999 0 =
7 '° °' ~
�'- gyp° °°c!NE°° ° '
�yGJ�
,� �I I ION��
5/25%�823
gEFORF y
�G
o
, o
9,�� ��'�
GING QQ�
CHATHAM-RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
TOWN OF SILER CITYOFFICE
50 0 25 50 100
PLAN AND PROFILE FORCEMAIN
STA. 372+50 TO STA. 387+00
SHEET
C=1 26
GRAPHIC SCALE DIVISION VALUE - 50 FEET
MANAGER
D. HONEYCUTT
DESIGNER
D. HONEYCUTT
2
5/9/23
DLH
NCDOT COMMENTS
1
03/14/23
DLH
NCDMLR COMMENTS
CHATHAM COUNTY, NORTH CAROLINA
PROJECT MANAGER
D. HONEYCUTT
REVIEWER
DATE
DECEMBER 2022
PROJECT #
13.04039
FUNDING #
N/A
NO.
DATE
BY
DESCRIPTION
2
o_
0
0
z
Q
Q
Q
U
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
PLAN
j
Regional Circle
Suite A
Pinehurst, NC 28374
910.295.3159
McgIIINC Firm License # C-0459
mcgillassociates.com
—DocuSigned by:
—52740 4' e000000
o
o�ooF �ssi0' o o%y
= o SEAL o o =_
-
o
o 034999 o -
o o%_
`
/- oo LNG I N E;ot" GJ���`
0000o y
��'�� � • HONE ,����\
5/2����Ld'1�3�\\
0
k
0
TREE UNE
NICHOLAS B DARK, JR & GAIL B
PIN NO. 8761-46-9006.000
PARCEL 17140
PROPOSED
18" 450 BEND
580
575
570
565
560
0
0
k
Fv �
PROPOSED 18" C905-DR 21
PVC FORCE MAIN
(3' MIN. COVER, TYP.)
PROPOSED
TEMPORARY SILT
FENCE, TYPICAL
-WETLAND CROSSING PER DETAIL
PROPOSED 18" C905-DR
PVC FORCE MAIN
(3' MIN. COVER, TYP.)
TREE LINE Zn
PROPOSED
� 0-0 �`N
�`� o5
(2) 18" 45' BEN S
���►
*fro
a
ROPOSED CON CT TO EXISTING
"F
MANHOLE (SE DETAILS)
�9►
/A�
hX
Mai
J
PROPOSED
18" 45° BEND
JAMES KEITH BOLING JR
PIN NO. 8761-46-4060.000
PARCEL 16389
�►
FF�/
3g5+2g g1
� ao�
cnrnrn� "F
2a �'
PROPOSED
18" 45° BEND
Oi
NOTE: LOCATIO OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE ONLY. l`S
EXACT LOCATIONS A TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR. 'Q�� 01<.
EXISTING I GROUND
PROFILE
SCALE: HORIZ. 1 "= 50'
VERT. 1 "= 1'
OSED 1$" C905-DR 21
MANHOLE (SEE (DETAILS) I I
580
575
570
565
560
1 555 1 1 1 1 / I I I I I I I I I I I I I 1 III 1 555 1
550
545
12"DIP SEWER
550
545
2 �d'�
540 � , ,,, .,. ,,, _ 540
�EFOR\
Q
\GING
388+00 389+00
1 03/14/23 DLH
NO. DATE I BY
5
390+00 391 +00 392+00 393+00 394+00
CHATHAM-RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
NCDMLR COMMENTS
DESCRIPTION
TOWN OF SILER CITY
CHATHAM COUNTY, NORTH CAROLINA
395+00
396+00 3961+50
50 0 25 50 100
GRAPHIC SCALE DIVISION VALUE = 50 FEET
OFFICE MANAGER DESIGNER
D. HONEYCUTT D. HONEYCUTT
PROJECT MANAGER REVIEWER
D. HONEYCUTT
PLAN AND PROFILE FORCEMAIN
STA. 387+00 TO STA. 395+28.91
DATE
DECEMBER 2022
PROJECT # FUNDING #
13.04039 N/A
SHEET
C=1 27
co
O
O
co
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
/ I 574 ----- PLAN
/ I /
-----
----------------
� h /
' � I
i
PROP_O_S_ED_--
PUMP/ELECT-RICALBUILDING
N: 728772.9818 _ 570 —
i - -F- 1838221 5744 '
�' 11 568 '
/
5 566
/
X X X X X _-X XX X X X X X -X -
/
/ 4
PROPOSED STAND-BY ___ - -- ----._-{e ---------------- -- - -- - -_-
GENERATOR WITH ACCE,�'-
/ PLATFORMS ON CON CRETE'PAD
'------------ -----
/ /' /' // ♦ C�J Uv Doi � � --
5ro
PROPOSED ROOF OYERHANG MEN
MEN
MENr------ --J
MENv
o _ _ _
— — cv
�
MEN---
/ 564 ■
00
MEN- — i
Al MEN
—J
PROPOSED LAY DOWN AREA
,4MM STA. 10+00.00 FM-1
N: 728719.7826 1.88
30.02' - -- - - ---I
MME E: 1838279.6786 10+00
SEE
/ Ii■■n
SEEEMN
EMN
now
MEN
/
/
X X X X X X X X
x
x
-- --_..5
x
--►----
0
1
,
/
/
/
/
/
/
I
N: 728772.9818
E: 1838311.5744
/
/41
PROPOSED LIMITS
OF DISTURBANCE
/
—566 ---��
PROPOSED CONCRETE WETWELL
S Sss
,
o .'S6�
16.'
X
x
J x
X
' / / __ __ PROPOSED 8" CABC
PROPOSED 18' SWING GATE
E: 1838221.5744
CD
w 1
>
Of
i
V-
'
' o _
tK
LLJ
----- Q I TEMPORARY SILT
- \\ s Li
I FENCE PER DETAIL
w
' ~�>
D z 7-D z ``
o ID 01�
PROPOSED SANITARY
SEWER BY OTHERS
PROPOSED 6' CHAIN LINK
` I SECURITY FENCE (SEE DETAIL)
*Z-ft' \\', 0
PROPOSED CONCRETE
Now WASHOUT AREA
N: 728692.9818
E: 1838311.5744
` \\ss
OPOSED 18" C905-DR 21
PVC FORCE MAIN
(3' MIN. COVER, TYP.)
o
U
I
11 fto
�\
PROPOSED 16
WIDE ASPHALT
-j
2
ACCESS DRIVE
o Q
o
I=
Sam1001
Q z
z
o
zIQ
.••
U
NOR
5 Regional Circle
Suite A
Pinehurst, NC 28374
910.295.3159
NC Firm License # C-0459
mcgillassociates.com
—DocuSigned by:
dLt G II ���,,
—52746����C$B6MS°Soo
gEFORF
= o SEAL -
O o0 034999 o ti
o
��
loo .o
N
lnE Gc
��HON��.�`��
QPQ�
5
GING
1 103/14/231 DLH
NO. I DATE I BY
NCDMLR COMMENTS
DESCRIPTION
CHATHAM-RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
TOWN OF SILER CITY
CHATHAM COUNTY, NORTH CAROLINA
10 0 5 10 20
GRAPHIC SCALE DIVISION VALUE = 10 FEET
OFFICE MANAGER
D. HONEYCUTT
PROJECT MANAGER
D. HONEYCUTT
DESIGNER
D. HONEYCUTT
REVIEWER
BUILDING SITE PLAN
DATE JPROJECT# FUNDING #
DECEMBER 2022 13.04039 N/A
SHEET
C=204
co
O
0
co
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
O
a
cD
U5
J_
Q
w
❑
❑
z
a
w
O
U
co
O
v
0
APPROVED WARNING TAPE
BACKFILL MATERIAL
24" ABOVE PIPE (PVC ONLY)
/ // // // // // // // // // // //
COMPACTED IN 6" LIFTS
\/\/\/\/\/\/\/\/\/\/\
BACKFILL MATERIAL \//\\\\/\\//\\//\\//\\//\\//\\//\\//\\/
\
COMPACTED IN 6" LIFTS/ �/
\\\\ \\\\\ \\\\ \\12 MAX, i
WI E
TOO ED DGEO UNRLESS OTETE HERWISE
SPECIFIED (
)
MANHOLE RING AND
\//\//\//\//\//\//\// L M �C� \ /\/\/
NOTE: NO CONCRETE PAD
REQUIRED IN PAVED AREAS
COVER PER DETAIL
FINISHED
— — —
BACKFILL MATERIAL
COMPACTED IN 3" LIFTS
/ \\j\\j\\j\\j\\j\\j\\j ` 6 MIN BACKFILL MATERIAL / /
/ /\//\//\//\//\//\//\//�/�/ / /\/\/ /\/\/
/\ COMPACTED IN 3" LIFTS�N
GRADE
T
PROPOSED I PROPOSED
\� \\//\\//\\///
\//\//\/ �P \//
O \ \/ / /\\/\\/\\
FINISHED GRADE WORD "WATER" CAST IN TOP
4f
I PVC PIPE
DUCTILEPIPE I
\\/\\/\ \\/\\/\ \
�/�
/ No.12 COATED COPPER
\ TRACING WIRE PVC ONLY \�\\�/�\�/\�/\�\
\ \ \ \
\\/\\/\\/ \//\//\//\
a . .
//\�/�\
//\ ° ' PRECAST CONCRETE
MANHOLE STEPS
/\ // ECCENTRIC MANHOLE
6„
w
® 16" O.C. CONE OR FLAT SLAB TOP
MATCH PIPE INVERTS DIP GASKETED ADAPTER FOR
UNDISTURBED UNDISTURBED
O Z w
°
D.I. PIPE TO PVC PIPE
EARTH EARTH
NOTE:
= 00
a ° a
BELL HOLES NOT SHOWN
STANDARD EXCAVATION OVERCUT EXCAVATION
o w ¢
w ❑
CONTRACTOR TO SUPPLY ° ,
CONNECTING HOSE WITH 316 STAINLESS STEEL
}
=
APPROPRIATE LENGTH OR BRASS PIPING
AND FITTINGS3" MIN.
NOTES:
a
°
S TRANSITION ADAPTER DIP TO PVC
1.
CONSTRUCTION OF TRENCHES SHALL COMPLY WITH ALL FEDERAL, STATE AND LOCAL SAFETY AND
ADJUSTABLE CAST IRON VALVE BOX
COMPACTED BACKFILL
o' Q
SEWAGE COMBINATION
° AIR VALVE
HEALTH REGULATIONS WHICH HAVE JURISDICTION AT THE PROJECT SITE. IT IS THE CONTRACTOR'S
(SCREW TYPE)
J a o
1 Q UPDATED MARCH, 2017
RESPONSIBILITY TO BE FAMILIAR WITH THE APPLICABLE REGULATIONS AND FOLLOW THEM ACCORDINGLY.
Q X:_ 0
NOT TO SCALE
2.
PAYMENT FOR ROCK EXCAVATION AND SELECT BACKFILL IN TRENCH SHALL BE FOR ACTUAL
'
V 3 Z
°
QUANTITIES AND SHALL NOT EXCEED THE WIDTH OF TRENCH SHOWN ON THIS DETAIL.
o a �
i
0M
Q w ZOf
QUICK CONNECT i i a ,
SHUTOFF VALVE W/ 5'0"� PRECAST
S SEWER FORCE MAIN TRENCHING
CONCRETE BRICK SUPPORT
0 _
z o 0
0U�
24" MIN. COUPLING i i ° MANHOLE RISER SECTION
(TROPE )F <
\
d a I�=
24 UPDATED MARCH, 2017
CONCRETE BRICK SUPPORT
° ' °
NOT TO SCALEBLOWOFF
/,\\/
a
VALVE W/ GATE FORCE MAIN
QUICK VALVE
COUPLING \
i
BRASS OR STAINLESS
STEEL PIPING
TEMPORA R V CONS TR UC TION EN IRA NCE / EXl T
COMPACTED BACKFILL
----
/
DEFINITION. GRAVELEDAREATOBELOCATEDATPOINTSWHERE VEH/CLES
MASONRY SEAL AT
ENDS OF
GROUT PIPE IN OVERSIZED
OPENING. NO CONTACT
ENTERANDLEAVEA SITE.
ENCASEMENT PIPE CARRIER PIPE��/��/��//��/��//
� BETWEEN PIPE AND MANHOLE
PURPOSE: TO PROVIDE A BUFFER AREA WHERE VEHICLES CAN DROP THEIR
- PLUG VALVE
STAINLESS STEEL MINIMUM 6" NO.
SERVICE SADDLE
MUD AND SEDIMENT TOAVOID TRANSPORTING ITONTOPUSLICROADS.
e °
57 WASHED STONE
(MATCH VALVE SIZE)
TOCONTROL EROSION FROM SURFACE RUNOFF AND TO HELP CONTROL DUST
a '° CONCRETE SUPPORT PAD 6" LARGER
<°
°
THAN VALVE (REQUIRED ON VALVES
10" AND LARGER ONLY)
NOTES:
CONDITIONS. MA/NTAIN/NACONDIT/ONWHICHWILLPREVENT TRACKING ORD/RECTFLOWOFMUDONTOADJACENT
1. COMBINATION AIR VALVE TO BE INSTALLED AT ACTUAL HIGH POINT OF LINE.
STREETS. RER/ODIC TOPDRESS/NGOFSTONE WILL BE NECESSARY ANYMATER/AL TRACKED ONTO
STEEL ENCASEMENT WEEP HOLE ON BOTTOM
OF THE PIPE AT THE
2. COMBINATION AIR VALVE SHALL BE OFFSET IN MANHOLE TO PROVIDE ACCESS.
ROADWAYMUSTBECLEANED UPIMMED/ATELY.
LOWER END
3. VALVE SIZE AS SHOWN ON DRAWINGS OR DETAILED IN THE SPECIFICATIONS.
PROVIDEANDINSTALL ADEQUATELVS/ZEDDRIVEWAYP/PE OF SUFFICIENT STRENGTH MA TER/AL TO
2 PIECE STAINLESS STEEL
SUPPORT AND SPACER w/
4. ALL PIPING AND VALVES FOR COMBINATION AIR VALVE SHALL BE BRASS,
WITHSTAND CONSTRUCTION TRAFFIC WITHOUTDEFORMAT/ON OF THE PIPE.
2 PER JOINT OF CARRIER PIPE
W PLUG VALVE
BRONZE OR STAINLESS STEEL OR OTHER CORROSION RESISTANT MATERIAL.
5. CONTRACTOR SHALL ADJUST THE DEPTH OF THE FORCE MAIN AT ALL HIGH
9 UPDATED MARCH, 2017
POINTS TO ACCOMMODATE THE INSTALLATION OF THE COMBINATION AIR
DESIGN CRITERIA: USECLASSA WASHED STONE WITHGEOTEXT/EEL/NER.
NOT TO SCALE
VALVE.
DIMENSIONS. THICKNESS OF8INCH MINIMUM CLASSASTONE
K"S�
SEWAGE FORCE MAIN COMBINATION AIR VALVE
WIDTH OF20 FOOT MINIMUM AND 50 FOOTMAXIMUM
31
UPDATED MARCH, 2017
LENGTH OF50FOOTMIN/MUM
STEEL ENCASEMENT
STEEL ENCASEMENT SOLID MASONRY
NOT TO SCALE
SEAL AT UPPER
LOCATION. LOCATECONSTRUCTION ENTRANCESANDEXITS TOL/MITSEDIMENTFROMLEA V/NGTHE S/TEANDTO
BOLT —ON TYPE SKID
END OF PIPE
PROV/DEFORMAXIMUM UT/L/TYBYALL CONSTRUCT/ON VEH/CLES. AVOID
OR STAINLESS STEEL
STEEP GRADES AND ENTRANCES A TCURVES ON PUBLIC ROADS.
INSTALL CONSTRUCT/ON ENTRANCES IN WAY TO PREVENT VEHICLES FROM BYPASSING CONSTRUCT/ON
ENTRANICE LEAVING PROJECT S/TE
NON —PENETRATING 4 — 1" ANCHOR
PICKHOLES (2)
PUBLIC ROAD
HOLES ® 90'
CENTERLINE OF INLET PIPING
STAINLESS STEEL BOLT
A O A
IS NOT ALLOWED IN EITHER
QUADRANT ADJOINING THE
---
MANHOLE OUTLET. Tl pNs
30' MINIMUM
WEEP HOLES
�� 00NNE
q .
A ° o � a ° ° 9° : ° 8 A
. .. ..
RADII - OR -
CARRIER
PIPE BOLT —ON TYPE SKID CARRIER PIPE w ON BOTTOM
_
LARGER TO
ACCOMMODATE '-
=''
(MIN. 2 PER JOINT, RESTRAINED JOINTS, AT LOWER
SPACED EVENLY) FIELD LOCK GASKETS END OF PIPE
HALF PLAN OF MANHOLE
MANHOLE 3
c
LARGEST _
OR EQUAL.
RING &COVER
STEPS 0 m
TURNING '• -' -'
8" MINIMUM -
VEHICLE - -
THICKNESS = '' = '' S0' MINIMUM
NOTE. FOR PRESSURE CARRIER PIPES, IF SUITABLE UNDISTURBED EARTH IS NOT AVAILABLE FOR THRUST BLOCKS
DUE TO EXCAVATION, CONTRACTOR SHALL ATTACH THREADED RODS AS SPECIFIED IN THRUST BLOCK DETAILS TO
. CLASS B
\\\��\// \\/ a CONCRETE
\ '
THE ENCASEMENT AND ROD FITTINGS DIRECTLY TO THE ENCASEMENT PIPE. ATTACHMENT OF THE RODS SHALL BE
BY WELDING DIRECTLY TO THE ENCASEMENT PIPE OR BY WELDING EYE BOLTS TO THE ENCASEMENT FOR
1'-11 1/2"
ATTACHMENT OF THREADED RODS WITH NUTS. MINIMUM OF THREE RODS REQUIRED PER FITTING.
�Eo-TEX LINER �� ;' ;, ;" ,,
•`':
00
M '�
4
SEWER
i : ,
° PIPE
-
S ENCASEMENT DETAIL - STANDARD
ii
°,° MANHOLE
STEPS
16 UPDATED MARCH, 2017
1/2"
SECTIONAL PLAN
NOT TO SCALE
a
20' MINIMUM
SECTION A -A
MINIMUM
NOT TO SCALE
MANHOLE COVER
STANDARD FITTINGS FOR FORCE MAIN CONNECTION,
MANHOLE IF REQUIRED, SHALL BE MADE WITH 45'
2'-1
16" Uj
w
U O N °
w�
z
z
0OQ ; s
U
N Z „
1'-11 3/4"
F p
Q
O(n-
0 Q ? U
LLj
4 — 1' ANCHOR
HOLES ® 90'
UNEXCAVATED
CLASS B
2'-1'
3"
1 — ° /\ CONCRETE
MIN.JA
2'-9 1/4°EFLEXIBLE
NTRANCEHJO INT LEEEE
BASE FOUNDATION CONSTRUCTED LEVEL
SECTION A -A
UNEXCAVATED WITH EXISTING MATERIAL OR WITH
MANHOLE RING
STONE STONE AS REQUIRED BY
SPECIFICATIONS
NOTE: IF FORCE MAIN CONNECTION IS MADE TO EXISTING MANHOLE, INVERT FOR
NOTE: TRAFFIC BEARING RING AND
FORCE MAIN SHALL BE CONSTRUCTED ON TOP OF EXISTING INVERT BENCH
COVER.
SECTION A -A
MINIMUM WEIGHT 315 POUNDS
MANHOLE RING AND COVER
S MANHOLE FORCE MAIN CONNECTION
NOT TO SCALE
30 UPDATED MARCH, 2017
NOT TO SCALE
5 Regional Circle
DocuSigned by:
e 6 "' '�����,,
5274Q,R�`\` ' c �o°A ROB "'''-,
;m000F ss o�9'
gEFOR
�'� F yoG
CHATHAM-RANDOLPH
SEWER
MEGASITE
SYSTEM EXTENSION
NOT TO SCALE
SHEET
°
• �'
MISCELLANEOUS DETAILS
Suite
_ °Q <°
o SEAL a
Pinehurst, NC 28374
O a 034999 oti `
• o
OF SILER CITY
C=501
OFFICE MANAGER
DESIGNER
910.295.3159
NC Firm License # C-0459
°
�'-'L N°ciE°C)
`fTOWN
y
D. HONEYCUTT
D. HONEYCUTT
y\
mcgillassociates.com
,oN
��;,,`�
��GQP
GING
CHATHAM
COUNTY NORTH CAROLINA
PROJECT MANAGER
REVIEWER
DATE
PROJECT #
FUNDING #
NO.
DATE
BY
DESCRIPTION
5/25%A23
'
D. HONEYCUTT
DECEMBER
2022
13.04039
N/A
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
O
a
(D
U5
J
Q
w
❑
❑
z
a
w
0
U
0)
co
O
v
0
CONCRETE
THRUST BLOCK
2" S9.5B OR S9.5C
SURFACE COURSE
A \` \/
A/2A/2 ,\\ \\ \\ \\ \ \\ \\ \\ \\ \
UNDISTURBED �\/ • \
EARTH
25' MIN. OR EDGE OF PAVEMENT 11" B25.OB OR B25.00 BASE
COURSE IN 2 LIFTS MIN.
TAPER TO EXISTING
SAWCUT EXISTING PAVEMENT
° • \\\ A/2
a
• .•°
/ �� BITUMINOUS TACK COAT
•,
'
I EXISTING 1
• ' • CONCRETE A
• - -i — i - -----------------
THRUST BLOCK
I EXISTING)
TR �����/ '
A/2
`
BITUMINOUS TACK COAT
\\/ ° • \\��
CONCRETE
U
r� 1'-0" 2'-0" PIPE 2'-0' 1'-0" \\/\
BEND BEND \ \\ '\\' UNDISTURBED EARTH
TRENCH BACKFILL SHALL
BE COMPACTED TO 100%
TYPICAL THRUST BLOCKS FOR BENDS
(FULL DEPTH - SEE NCDOT
SPEN 6 \/ 000, //\� //
SUBSECTION 3.1/j�j/\ UNDISTURBED EARTH
CONCRETE THRUST „� // BLOCK \
TRENCH
6" SCH. 40 STEEL OR IRON
FILLED WITH CONCRETE,
PAVEMENT REPAIRS ON ROADS TO BE RESURFACED
WIDTH / / / • //� /�/
THREADED ROD (GALVANIZED
\/\\/\\//
PIPE
OW. PRIME
PRIOR TO PAINTING
PPE
'')
' ° 12" MIN.' j12/MIN.\�
//\ %
\\//\\j/\\j\ / / / / — / %/\� , OR BITUMINOUS COATED)
2" S9.58 OR S9.5C
Q • Iq
SURFACE COURSE
12" MIN.
11" B25.01B OR B25.00 BASE
COURSE IN 2 LIFTS MIN.
••. 1• 9
SAWCUT EXISTING PAVEMENT
/�\\/�\\ , MIN. • TRENCH a�
° WIDTH
•
y\\\/\\\ �• •�� �/\\ -rA.—
EXISTING
BITUMINOUS TACK COAT
—— — — — — — — — — — — — — — — — — -- ---
} 6
/\/\ °, ° ' \/\ • `rr a =��
/ =ii
�\ \\ ° a \\ i
///�
GROUND
r\\ a" •
\
°
\/\ `\// \/
j\\\ /. /
\
i
I EXISTING
EXISTING
,°
12" MIN. °. \ �i
/i�\//\\//\\//\ •
/
/
//\\
/\\�\\�\\�\\�\\� \\�\\�\\�\\�� ° . a .. //\\//\\//\
\\/\\/\\/ /\\ �\
//\//\//, / / / / /\/ 4 PIPE
\\/ /\/\/\ DIAMETERS
\\///
CONCRETE
\ °
i //
\\
\/
/\\ °
\/
\/ °0
° \\
/
\\%\\%\\%\\%\\ >
BITUMINOUS TACK COAT \r\\\\\\\\ \\\/\\\/\\\/���/ O
'\///�/j /�
`\/\\ 1'-0" 2'-0" PIPE 2'-0" 1'-0" \\j
THREADED ROD (GALVANIZED
/ \/////
a,
O.D.\\
OR BITUMINOUS COATED) UNDISTURBED EARTH
�/
Z
TYPICAL THRUST BLOCK FOR REDUCERS
12" MIN.
TRENCH BACKFILL SHALL
BE COMPACTED TO 100%
(FULL DEPTH - SEE NCDOT /
SPECA, SECTION 312000,
r r/rr/rr r r
BOCK ETE THRUST \// / 24" MIN.
SUBSECTION 3.16) UNDISTURBED EARTH
TRENCH \ •'
WIDTH //\//\\// ..
/ • •• ' \12" MIN .\\ THREADED ROD (GALVANIZED
j\/\//\//\// 12 MIN.' //\/ \//\/. OR BITUMINOUS COATED)
PAVEMENT REPAIRS ON ROADS NOT TO BE RESURFACED
/\\\/
• \ iq °
\\ +� ° 1 ° °n PLUG
.12" MIN. \/° L==_
\\//\\ 1 ° ° 1
"•
M
BOLLARD
DETAIL
NOTES:
1. EDGE TO BE SAWED WITH A CONCRETE SAW TO A NEAT SQUARED EDGE AND CLEANED OF DUST BEFORE TACK COAT IS
APPLIED.
• 2" /
MIN.. TRENCH —am- 9
7
UPDATED MARCH2017
2. EDGES TO BE TACKED WITH CRS—I OR CRS—II.
3. THICKNESS OF B25.OB OR B25.0 BASE COURSE AND S9.5B OR S9.5C SURFACE COURSE SHALL MATCH
EXISTING CONDITIONS IF GREATER THAN SHOWN ON DETAILS.
WIDTH
�\\\/\\\ •, �, c \ _ r°_ °
,
NOT TO SCALE
4. CONTRACTOR RESPONSIBLE FOR REPLACEMENT OF ANY PAVEMENT MARKINGS DISTURBED OR COVERED BY OVERLAY.
/ ' •
12" MIN.. \ \�\' 'i
• °
ST TYPICAL PAVEMENT REPAIRS - NCDOT ROADS
\\\\\ — —
° • •° — 3/4" TAP W/
/\\ \\ \\ \\ \\ \ \\ \\ \ \\/` \/�\/\\/\\/\ ° • . /\\�\\�\\ CORPORATION
\
UPDATED MARCH, 2017
NOT TO SCALE
°° STOP FOR AIR
PRESSURE RELIEF
THREADED ROD (GALVANIZED
OR BITUMINOUS COATED) UNDISTURBED EARTH �\ /
TYPICAL THRUST BLOCK FOR PLUGS
A
A/2 A/2 UNDISTURBED
EARTH
o
YARD HYDRANT WOODFORD
IOWA MODEL Y1 OR
9"
APPROVED EQUAL
4• CONCRETE
,• THRUST BLOCK
BARBED WIRE (3 STRANDS)
°
CONCRETE \\\\�/\\//\\�/\\�/\\�/\
•, • THRUST BLOCK
�—
STANDARD NOZZLE
WITH
10'-0" MAX.(TYP.)WELD ALL JOINTS
CORNER POST CAP TMATCH
, •. "
OPTIONAL 1" NOZZLE
BARBED WIRE USEDI INLINE OF FENCE PADLOCK HOLE
• °:� O O O , A/2
(3 STRANDS)
i
&7E E E 3 O O 3-- A
EL EL° ' O O O A/2
27 1 /2"
18" ,
24"
TEE j\
WIRE TIES
2j" CORNER POST 15" O.C. (TYP) 1j" TOP POST
TENSION BAR
TEE UNDISTURBED EARTH
No.9 GAUGE WIRE
2 MESH (TYP.)
6x6 10/10 WWF
6'-0"
cTYP.)
TYPICAL THRUST BLOCKS FOR TEES
TENSION BAR
•
�3'-6"xf-6%4"
2j" LINE POST
NOTES:
1. FITTING JOINTS SHALL NOT BE POURED IN CONCRETE OR HAVE CONCRETE SPILLED ON THE BOLTS OR NUTS.
CONCRETE SPLASH BLOCK
TENSION WIRE
THE FITTING SHALL BE WRAPPED IN A LAYER OF POLYETHYLENE PLASTIC PRIOR TO POURING THE THRUST BLOCK.
2. ROD AND EYE BOLT DIAMETER SHALL BE A MINIMUM OF 3/4" AND SHALL MATCH THE SIZE OF THE BOLT
STD. VALVE
PROVIDED WITH THE FITTING.
BOX AND LID
3. CONTRACTOR SHALL REPLACE FITTING BOLTS WITH THREADED ROD FOR 1/2 OF THE BOLTS SUPPLIED WITH
EACH FITTING. RODS SHALL BE EQUALLY SPACED.
36" MIN. BURY DEPTH
%
j 2" CLEARANCE `/ // // // // // // // // // // // /r' // ///\ // // / / / /////.///.///.///.///.///.///�////
°• /// /�
•°
a
TYPE
1" GALVANIZED
STEEL CASING PIPE
i
/ • //� �\ ' \\ GALV. STD. PIPE M N.
<, j \�3'-0" '\ /\ / SEMI -SELF DRAINING
/ /�'
\
/
SIZE 11-1 4° BEND 22-1 2° BEND 45° BEND 90° BEND TEE PLUG
/ /
I I
j •
/ \ ° �\
\ . MIN. \ \\/\ \ CENTER STOP\
2500 PSI \ () /\ //\ MIN.
CONCRETE (TYP) ° \ j\\ • \
\
IV, 3' -0"
/ MIN.
j (TYP.)
286
12
12
12
6
14
12
12
16
22
22
18
]
\ . <
/ \\ • • \ j\ 2500 PSI
J// e • /
10
12
14
20
28
28
22
12
12
18
24
32
32
28
1" VALVE BODY
WITH 1" NPT INLET
\ ,\ \�\ \/\ CONCRETE
/3" MIN. CONCRETE
(TYP.)
.)
MIN. (TYP.)
(am-)
\
- 3" MIN.
MIN. (TYP.)
(TYP.)
14
14
14
20
28
38
38
32
16
16
22
32
42
42
36
18
18
26
36
48
48
40
1" PVC
20
20
28
40
52
52
44
CONCRETE BLOCK
1" VALVE W/
#67 STONE
24
24
34
46
64
64
54
30
30
42
58
78
78
66
HANDWHEEL OPERATOR
M and
36
36
50
1 70
94
1 94
1 80
42
40
58
80
108
108
1 92
48
46
66
90
124
124
104
29 UPDATED MARCH, 2017
THRUST BLOCK DIMENSION "A„
NOT TO SCALE
rS_'% THRUST BLOCKING -ALL
W
YARD HYDRANT
28 UPDATED MARCH, 2017
44
UPDATED MARCH, 2017
NOT TO SCALE
NOT TO SCALE
5 Regional Circle
DocuSigned by:
L �
52�4 ����®°ARo�
��o°oFEss�o�,°°�ti
zaQ� 9<�� =
gEFOR O
�� Fyn
Q� o�
• �'
CHATHAM-RANDOLPH
SEWER
MEGASITE
SYSTEM EXTENSION
NOT TO SCALE
MISCELLANEOUS DETAILS
SHEET
Suite
Pinehurst, NC 28374
a 034999 0
• o
OWN
OF SILER CITYOFFICE
C=502
MANAGER
DESIGNER
910.295.3159
NC Firm License # C-0459
Q
= v °° °°�
,,y°°°J
�'- /p�°ciNE°�°c,
' y\
`fy k,�
D. HONEYCUTT
D. HONEYCUTT
2
5/9/23
DLH
NCDOT
COMMENTS
CHATHAM
COUNTY NORTH CAROLINA
PROJECT MANAGER
REVIEWER
DATE
PROJECT #
FUNDING #
mcgillassociates.com
, ,,���HONE,,``
��
��GGING QP
NO.
DATE
BY
DESCRIPTION
5/2 5%�023
'
D. HONEYCUTT
DECEMBER 2022
13.04039
N/A
w
U)
a
c7
w
D-
J
0
❑
z
a
o'
a
Q
U
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
r`
IP
00
co
R
�I
Q
❑
0
J
o_
c�
n
U5
Q
w
❑
z
a
D'
w
>
O
U
co
co
0
v
0
1'-0 1'-0
TO MATCH EXISTING GRAVEL SURFACE
EXISTING BASE COURSE EXISTING BASE COURSE
DRY/
CUNDISTURBED
EARTH
_6" LIFTS OF SUITABLE SOIL
OR CABC AT OPTIMUM
MOISTURE COMPACTED 95%
STANDARD PROCTOR
PIPE
sn GRAVEL DRIVE REPAIR
6 UPDATED MARCH, 2017
NOT TO SCALE
1'-0 1'-0
6"-3000 PSI CONCRETE SAWCUT EXISTING EDGE
TO MATCH EXISTING TO PROVIDE NEAT
CONCRETE SURFACE STRAIGHT EDGE PRIOR TO
REPAIR
EXISTING CONCRETE °EXISTING CONCRETE 6"
° . �.' . . . G1 °
EXISTING BASE COURSE "
6 MIN. CABC COkt
MPACTED
EXISTING BASE COURSE
.. ... .. ... TAil Q4
O ,100 STD. PROCTOR / 6"
DRY/
CUNDISTURBED
EARTH
6" LIFTS OF SUITABLE SOIL
OR CABC AT OPTIMUM
MOISTURE COMPACTED 95%
STANDARD PROCTOR
PIPE
CONCRETE DRIVE REPAIR
2" LIFTS OF ASPHALT
TYPE SF 9.5A TO
MATCH EXISTING
PAVEMENT THICKNESS
DRY/
CUNDISTURBED
EARTH
UPDATED MARCH, 2017
NOT TO SCALE
" MIN. CABC COMPACT
0 100% STD. PROCTOR
V-0 TACK EXISTING PAVEMENT
EDGE WITH CRS-I OR CRS-II.
PATCH TO MATCH EXISTING
PAVEMENT
EXISTING PAVEMENT 2" MIN.
XISTING BASE COURSE
6" MIN.
LIFTS OF SUITABLE SOIL
MIN.
\j\\j� OR CABC AT OPTIMUM
MOISTURE COMPACTED 95%
STANDARD PROCTOR
PIPE
/\\//\\/\
NOTE:
1. EDGE TO BE SAWED WITH A CONCRETE SAW TO A NEAT SQUARED EDGE AND CLEANED OF
DUST BEFORE TACK COAT IS APPLIED.
2. EDGES TO BE TACKED WITH EMULSIFIED ASPHALT TACK CRS-I OR CRS-II.
ST ASPHALT DRIVE REPAIR
UPDATED MARCH, 2017
NOT TO SCALE
EXISTING
GROUND
DESIGN SETTLED
TOP
12" MIN. OF NCDOT #5
OR #57 WASHED STONI
3600 CU FT/ACRE
1. 5' MIN.
21" MIN.
AI E
DRAINAGE AREA
WEIR LENGTH 1
ACRES
FT.
1
4.0
2
6.0
3
8.0
4
10.0
5
12.0
1 DIMENSIONS SHOWN ARE MINIMUM
5' MAX.
FIL
SECTION VIEW
12" MIN. OF NCDOT #5 OR
#57 WASHED STONE,
OVERFILL 6" FOR SETTLEMENT
4'
MIN.
J<-��C�];emo\\\ L EMERGENCY BY-PASS
J6" BEL
/\/\/\/TOP OFODAM TILED
\ EXISTING
� 3. 4� GROUND
MIN.
WEIR VIEW
MAINTENANCE SCHEDULE:
1. AT A MINIMUM, TEMPORARY SEDIMENT TRAPS SHALL BE INSPECTED
WEEKLY AND AFTER EACH RAINFALL EVENT GREATER THAN 1/2-INCH.
2. REMOVE SEDIMENT AND RESTORE TRAP TO ITS ORIGINAL DIMENSIONS
WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN
DEPTH OF THE TRAP.
3. PLACE THE SEDIMENT THAT IS REMOVED IN A DESIGNATED DISPOSAL
AREA AND REPLACE THE CONTAMINATED PART OF THE GRAVEL FACING.
DISPLACED RIP -RAP SHALL BE REPLACED IMMEDIATELY.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ACCESS WITHIN
LIMITS OF DISTURBED AREA TO ALL SEDIMENT TRAPS FOR MAINTENANCE
DURING CONSTRUCTION AND REMOVAL UPON PROJECT COMPLETION.
NOTE:
1. SEE BAFFLE DETAIL FOR BAFFLE INSTALLATION PROCEDURE AND SPACING.
CONSTRUCTION SPECIFICATIONS
1. CLEAR, GRUB, AND STRIP THE AREA UNDER THE EMBANKMENT OF ALL VEGETATION AND ROOT MAT. REMOVE ALL SURFACE SOIL CONTAINING HIGH
AMOUNTS OF ORGANIC MATTER, AND STOCKPILE OR DISPOSE OF IT PROPERLY. HAUL ALL OBJECTIONABLE MATERIAL TO THE DESIGNATED DISPOSAL
AREA.
2. ENSURE THAT FILL MATERIAL FOR THE EMBANKMENT IS FREE OF ROOTS, WOODY VEGETATION, ORGANIC MATTER, AND OTHER OBJECTIONABLE
MATERIAL. PLACE THE FILL IN LIFTS NOT TO EXCEED 9 INCHES, AND MACHINE COMPACT IT. OVER FILL THE EMBANKMENT 6 INCHES TO ALLOW FOR
SETTLEMENT.
3. CONSTRUCT THE OUTLET SECTION IN THE EMBANKMENT. PROTECT THE CONNECTION BETWEEN THE RIPRAP AND THE SOIL FROM PIPING BY USING
FILTER FABRIC OR A KEYWAY CUTOFF TRENCH BETWEEN THE RIPRAP STRUCTURE AND SOIL.
PLACE THE FILTER FABRIC BETWEEN THE RIPRAP AND THE SOIL. EXTEND THE FABRIC ACROSS THE SPILLWAY FOUNDATION AND SIDES TO THE TOP
OF THE DAM; OR
EXCAVATE A KEYWAY TRENCH ALONG THE CENTER LINE OF THE SPILLWAY FOUNDATION EXTENDING UP THE SIDES TO THE HEIGHT OF THE DAM.
THE TRENCH SHOULD BE AT LEAST 2 FEET DEEP AND 2 FEET WIDE WITH 1:1 SIDE SLOPES.
4. CLEAR THE POND AREA BELOW THE ELEVATION OF THE CREST OF THE SPILLWAY TO FACILITATE SEDIMENT CLEANOUT.
5. ALL CUT AND FILL SLOPES SHOULD BE 2:1 OR FLATTER.
6. ENSURE THAT THE STONE (DRAINAGE) SECTION OF THE EMBANKMENT HAS A MINIMUM BOTTOM WIDTH OF 3 FEET AND MAXIMUM SIDE SLOPES OF
1:1 THAT EXTEND TO THE BOTTOM OF THE SPILLWAY SECTION.
7. CONSTRUCT THE MINIMUM FINISHED STONE SPILLWAY BOTTOM WIDTH, AS SHOWN ON THE PLANS, WITH 2:1 SIDE SLOPES EXTENDING TO THE TOP
OF THE OVER FILLED EMBANKMENT. KEEP THE THICKNESS OF THE SIDES OF THE SPILLWAY OUTLET STRUCTURE AT A MINIMUM OF 21 INCHES. THE
WEIR MUST BE LEVEL AND CONSTRUCTED TO GRADE TO ASSURE DESIGN CAPACITY.
8. MATERIAL USED IN THE STONE SECTION SHOULD BE A WELL -GRADED MIXTURE OF STONE WITH A D50 SIZE OF 9 INCHES (CLASS B EROSION
CONTROL STONE IS RECOMMENDED) AND A MAXIMUM STONE SIZE OF 14 INCHES. THE STONE MAY BE MACHINE PLACED AND THE SMALLER STONES
WORKED INTO THE VOIDS OF THE LARGER STONES. THE STONE SHOULD BE HARD, ANGULAR, AND HIGHLY WEATHER -RESISTANT.
9. DISCHARGE INLET WATER INTO THE BASIN IN A MANNER TO PREVENT EROSION. USE TEMPORARY SLOPE DRAINS OR DIVERSIONS WITH OUTLET
PROTECTION TO DIVERT SEDIMENT -LADEN WATER TO THE UPPER END OF THE POOL AREA TO IMPROVE BASIN TRAP EFFICIENCY (REFERENCES:
RUNOFF CONTROL MEASURES AND OUTLET PROTECTION).
MAINTENANCE
MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC
TOPDRESSING WITH 2-INCH STONE. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY.
IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS.
rP-EC TEMPORARY SEDIMENT TRAP
26 UPDATED MARCH, 2017
NOT TO SCALE
MATCH EXISTING
PAVEMENT
I EXISTING
BITUMINOUS
TACK COAT
TRENCH BACKFILL SHALL -
BE COMPACTED TO 100%
(FULL DEPTH - SEE NCDOT
SPECA, SECTION 312000,
SUBSECTION 3.16)
2" ASPHALT SURFACE
COURSE (TYPE SF 9.5A)
6" TYPE 1 19.013 BITUMINOUS BINDER COURSE
/ IN TWO 3" COMPACTED LIFTS
6" C.A.B.C. IN TWO 3" COMPACTED LIFTS
COMPACTED TO 100% COMPACTION - STANDARD
1'-0" PIPE
MAX. O.D. MAX. BITUMINOUS
TACK COAT
UNDISTURBED EARTH
ST TYPICAL PAVEMENT REPAIRS
>
O
O
U
I
g
NOTES:
Z
1.
EDGE TO BE SAWED WITH A
CONCRETE SAW TO A NEAT
SQUARED EDGE AND CLEANED
OF DUST BEFORE TACK COAT
IS APPLIED.
2.
EDGES TO BE TACKED WITH
CRS-I OR CRS-11.
3.
THICKNESS OF CABC STONE,
1-19.OB BINDER AND SF 9.5A
SURFACE COURSE SHALL
MATCH EXISTING CONDITIONS
IF GREATER THAN SHOWN ON
DETAILS.
4.
CONTRACTOR RESPONSIBLE
FOR REPLACEMENT OF ANY
PAVEMENT MARKINGS
DISTURBED OR COVERED BY
OVERLAY.
UPDATED MARCH, 2017 I �-
NOT TO SCALE
STANDARD METAL POSTS
"-0" IN GROUND
LVANIZED HARDWARE WIRE
TENDS TO TOP OF BOX
>CED TO A HEIGHT OF
16 MINIMUM rABOVE �TOP OF BOX
CONSTRUCTION SPECIFICATIONS
1. UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET.
2. DRIVE 5-FOOT STEEL POSTS 2 FEET INTO THE GROUND SURROUNDING THE INLET. SPACE POSTS EVENLY
AROUND THE PERIMETER OF THE INLET, A MAXIMUM OF 4 FEET APART.
3. SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH. SECURE THE WIRE MESH TO THE STEEL
POSTS AT THE TOP, MIDDLE, AND BOTTOM. PLACING A 2-FOOT FLAP OF THE WIRE MESH UNDER THE
GRAVEL FOR ANCHORING IS RECOMMENDED.
4. PLACE CLEAN GRAVEL (NC DOT #5 OR #57 STONE) ON A 2:1 SLOPE WITH A HEIGHT OF 16 INCHES
AROUND THE WIRE, AND SMOOTH TO AN EVEN GRADE.
5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ACCUMULATED SEDIMENT, AND
ESTABLISH FINAL GRADING ELEVATIONS.
6. COMPACT THE AREA PROPERLY AND STABILIZED IT WITH GROUNDCOVER.
MAINTENANCE:
INSPECT THE BARRIER AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL
AND MAKE REPAIRS AS NEEDED. REMOVE SEDIMENT AS NECESSARY TO PROVIDE ADEQUATE STORAGE
VOLUME FOR SUBSEQUENT RAINS. WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEEN ADEQUATELY STABILIZED,
REMOVE ALL MATERIALS AND ANY UNSTABLE SOIL, AND EITHER SALVAGE OR DISPOSE OF IT PROPERLY.
OR DISPOSE OF IT PROPERLY. BRING THE DISTURBED AREA TO PROPER GRADE, THEN SMOOTH AND COMPACT
IT. APPROPRIATELY STABILIZE ALL BARE AREAS AROUND THE INLET.
-ECG GRATED INLET PROTECTION
15 UPDATED MARCH, 2017
NOT TO SCALE
TEMPORA R Y CONS TR UC TION EN TRA NICE / EXI T
DEFINITION:
GRA VEL ED A REA TO BE L OCA TED A T POIN TS WHERE VEHICL ES
ENTER AND LEA VEA SITE
PURPOSE:
TO PRO VIDE A BUFFER AREA WHERE VEHICLES CAN DROP THEIR
MUD AND SEDIMENT TO AVOID TRANSPORTING IT ONTO PUBLIC ROADS.
TO CONTROL EROSION FROM SURFACE RUNOFF AND TO HELP CONTROL DUST
CONDITIONS.
MAINTAIN INA CONDITION WHICH WILL PREVENT TRACKING OR DIRECT FLOW OF MUD ONTO ADJACENT
STREETS. RER1001C TOPORESSING OF STONE WILL BE NECESSARY. ANY MATERIAL TRACKED ONTO
ROADWA YMUSTBE CLEANED UP IMMEDIATEL Y
PRO VIDEAND INSTALL ADEQUA TEL Y SIZED DRIVEWA YPIPE OF SUFFICIENT STRENGTH MATERIAL TO
WITHSTAND CONSTRUCTION TRAFFIC WITHOUT DEFORMATION OF THE PIPE.
DESIGN CRITERIA.
USECLASSA WASHEDSTONE WITHGEOTEXTILELINER.
DIMENSIONS.
THICKNESS OF8INCH MINIMUMCLASS ASTONE
WIDTH OF20 FOOT MINIMUMAND 50 FOOT MAXIMUM.
LENGTH OF 50 FOOT MINIMUM
LOCATION.
LOCATECONS TRUCTIONENTRANCES ANOEXITSTOLIM1TSEDIMENTFROM LEAVINGTHE S/TEANOTO
PROVIDEFORMAXIMUMUTILITYBYALL CONSTRUCTION VEHICLES. AVOID
STEEP GRADES AND ENTRANCESA TCURVES ON PUBLIC ROADS.
INSTALL CONSTRUCTION ENTRANCES INA WAY TO PREVENT VEHICLES FROM BYPASSING CONSTRUCTION
ENTRANCE LEAVING PROJECT SITE.
PUBLIC
ROAD
30' MINIMUM
RADII - OR - -
r-;.
LARGER TO
ACCOMMODATE
LARGEST _
TURNING
VEHICLE 8" MINIMUM _
THICKNESS '' 50' MINIMUM
GEO-TEX LINER
20' MINIMUM
NOT TO SCALE
INSTALL 19GA
HARDWARE CLOTH
AND STONE-__
DROP INLET
#57 WASHED STONE
°�
U
• I
°ve
'd
w
J
U)
U_
O
O
U)
PLAN
Uj
X
19 GA. HARDWARE 5' LONG HEAVY DUTY STEEL
�
CLOTH WITH Y4" MESH T-POSTS SET 24" MIN. INTO
w
GROUND (MAX. 4' SPACING)
Cn
N0. 57 WASHED STONE
Of
--
21 EXCAVATED AREA
uJ
24" __
__
t__,__I`
FOR SEDIMENT
w
16"
GROUND STORAGE
a
°
\,\/��
'\ 18"
w
/
OPENING
�i
n
, .,
Q
W
CATCH BASIN
5't �{
a
32"
J
O
❑
z
Q
NOTES: CONSTRUCTION SPECIFICATIONS
1. ATTACH HARDWARE TO 1. UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET.
Q
OUTSIDE OF FENCE POSTS WITH 2. DRIVE 5-FOOT STEEL POSTS 2 FEET INTO THE GROUND SURROUNDING THE
APPROVED FASTENERS. INLET. SPACE POSTS EVENLY AROUND THE PERIMETER OF THE INLET, A MAXIMUM
=
OF 4 FEET APART.
U
2. FILTERS SHALL BE INSPECTED 3. SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH. SECURE THE WIRE
WEEKLY AND AFTER EVERY MESH TO THE STEEL POSTS AT THE TOP, MIDDLE, AND BOTTOM. PLACING A
RAIN AND REPAIRED AS 2-FOOT FLAP OF THE WIRE MESH UNDER THE GRAVEL FOR ANCHORING IS
o
REQUIRED. RECOMMENDED.
�2
4. PLACE CLEAN GRAVEL (NC DOT #5 OR #57 STONE) ON A 2:1 SLOPE WITH A
3. SEDIMENT SHALL BE REMOVED HEIGHT OF 16 INCHES AROUND THE WIRE, AND SMOOTH TO AN EVEN GRADE.
AFTER DEPOSITS REACH HEIGHT 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE
OF BARRIER. ACCUMULATED SEDIMENT, AND ESTABLISH FINAL GRADING ELEVATIONS.
4. STEEL POSTS SHALL BE 6. COMPACT THE AREA PROPERLY AND STABILIZE IT WITH GROUNDCOVER.
MINIMUM 1:33 POUND PER L.F. MAINTENANCE
5. REF: NCDENR 6.51.1 INSPECT INLETS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH OR
GREATER) RAINFALL EVENT. CLEAR THE MESH WIRE OF ANY DEBRIS OR OTHER
OBJECTS TO PROVIDE ADEQUATE FLOW FOR SUBSEQUENT RAINS. TAKE CARE NOT
TO DAMAGE OR UNDERCUT THE WIRE MESH DURING SEDIMENT REMOVAL. REPLACE
STONE AS NEEDED.
E C
rP-ECINLET PROTECTION
14 UPDATED MARCH, 2017
NOT TO SCALE
RIPRAP CHECK DAM
1"� ill
1�•l. 1 1 1
•
l o I
I I PROPOSED
I� I
WATER OR SEWER
I w I LINE
I� I
I c�i I
LZ J
CONSTRUCTION SPECIFICATIONS
1. CLEAR THE AREA OF ALL DEBRIS THAT MIGHT HINDER EXCAVATION AND DISPOSAL OF
SPOIL.
2. INSTALL THE CLASS B OR CLASS I RIPRAP IN A SEMI -CIRCLE AROUND THE PIPE
INLET. THE STONE SHOULD BE BUILT UP HIGHER ON EACH END WHERE IT TIES INTO THE
EMBANKMENT. THE MINIMUM CREST WIDTH OF THE RIPRAP SHOULD BE 3 FEET, WITH A
MINIMUM BOTTOM WIDTH OF 11 FEET. THE MINIMUM HEIGHT SHOULD BE 2 FEET, BUT
ALSO 1 FOOT LOWER THAN THE SHOULDER OF THE EMBANKMENT OR DIVERSIONS.
3. A 1 FOOT THICK LAYER OF NC DOT #5 OR #57 STONE SHOULD BE PLACED ON THE
OUTSIDE SLOPE OF THE RIPRAP.
4. THE SEDIMENT STORAGE AREA SHOULD BE EXCAVATED AROUND THE OUTSIDE OF THE
STONE HORSESHOE 18 INCHES BELOW NATURAL GRADE.
5. WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, FILL DEPRESSION
AND ESTABLISH FINAL GRADING ELEVATIONS, COMPACT AREA PROPERLY, AND STABILIZE
WITH GROUND COVER.
MAINTENANCE
INSPECT ROCK PIPE INLET PROTECTION AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT
(1/2 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT
AND RESTORE THE SEDIMENT STORAGE AREA TO ITS ORIGINAL DIMENSIONS WHEN THE
SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE
THE SEDIMENT THAT IS REMOVED IN THE DESIGNATED DISPOSAL AREA AND REPLACE THE
CONTAMINATED PART OF THE GRAVEL FACING. CHECK THE STRUCTURE FOR DAMAGE.
ANY RIPRAP DISPLACED FROM THE STONE HORSESHOE MUST BE REPLACED IMMEDIATELY.
AFTER ALL THE SEDIMENT -PRODUCING AREAS HAVE BEEN PERMANENTLY STABILIZED,
REMOVE THE STRUCTURE AND ALL THE UNSTABLE SEDIMENT. SMOOTH THE AREA TO
BLEND WITH THE ADJOINING AREAS AND PROVIDE PERMANENT GROUND COVER.
-EC) EXISTING CULVERT PROTECTION
20 UPDATED MARCH, 2017
NOT TO SCALE
DocuSigned by:
a��8�°ARo,,�gEFORF yo CHATHAM-RANDOLPH MEGASITE SHEET
5 Regional Circle o°oFESSIo�,°�/ti ��' �'o� NOT TO SCALE
Suite A ? SEAL
a¢� 9.' _ �� • SEWER SYSTEM EXTENSION
MISCELLANEOUS DETAILS
-°
Pinehurst, NC 28374 a a 034999 0 , o TOWN OF SILER CITYOFFICE MANAGER DESIGNER
910.295.3159
°°°,y°°°J `fy k,� C=503
D. HONEYCUTT D. HONEYCUTT
NC Firm License # C-0459 /p�,cINE°�°Cj ,c' �'
' , y\ �� � �� PROJECT MANAGER REVIEWER DATE PROJECT # FUNDING #
''',��; "oNE�,'' ��GGING QP 2 5/9/23 DLH NCDOT COMMENTS CHATHAM COUNTY NORTH CAROLINA mcgillassociates.com s/z '�a�3
NO. DATE BY DESCRIPTION I D. HONEYCUTT DECEMBER 2022 13.04039 N/A
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
PIPE OUTLET TO WELL-DEFINED
SAND BAG BERM TEMPORARY PIPE (SIZED TO
/-CARRY NORMAL FLOW)
EXISTING EXISTING
CREEK BANK �x X�7� CREEK BANK
INSTALL PIPE UNDER
TEMPORARY PIPE
SECTION A -A
SECTION B-B
,GS
STREAM
BED
VVM I F-R Vn oL vYL LINE
B4-1
EXISTING CREEK
1 I
TEMPORARY PIPE (SIZED TO
SAND BAG BERM CARRY NORMAL FLOW)
I
w
INSTALL PIPE
UNDER TEMPORARY
PIPE
SAND BAG BERM
AL
EC
34
PROPOSED
:R OR SEWER
�A
PLAN
NOTE: ALL DISCHARGE FROM DE -WATERING THE WORK
AREA SHALL BE PUMPED TO EITHER A TEMPORARY
SEDIMENT TRAP OR DE -WATERING SILT BAG PER DETAILS
CREEK CROSSING - MEDIUM
UPDATED MARCH, 2017
NOT TO SCALE
CLASS B RIPRAP
12" NCDOT No. 5, OR 12"
No. 57 WASHED STONE
FLU -\\
FILTER FABRIC
A
FILTER
1TTA
1»'/.i%
SECTION A -A
FACE VIEW
REFERENCE NCDENR LAND
QUALITY SECTION DESIGN MANUAL:
6.83
THE FOLLOWING CRITERIA SHOULD BE
USED WHEN DESIGNING A CHECK DAM:
- DRAINAGE AREA IS LIMITED TO ONE
HALF ACRE.
- KEEP THE MAXIMUM HEIGHT OF 2 FT
AT THE CENTER OF THE CHECK DAM.
- KEEP THE CENTER OF THE CHECK
DAM AT LEAST 9 INCHES LOWER
THAN THE OUTER EDGES AT
NATURAL GROUND ELEVATION.
- KEEP THE SIDE SLOPES OF THE DAM
AT 2:1 OR FLATTER.
- KEY THE STONE INTO THE DITCH
BANKS AND EXTEND BEYOND THE
ABUTMENTS 1.5 FEET MINIMUM TO
AVOID WASHOUTS FROM OVERFLOW
AROUND DAM
- STABILIZE OUTFLOW AREAS ALONG
B THE CHANNEL TO RESIST EROSION A L
(SEE PLANS) CAUSED BY CHECK DAMS.
L = THE DISTANCE SUCH THAT POINTS
A AND B ARE OF EQUAL ELEVATION
DETAIL
CONSTRUCTION SPECIFICATIONS
1. PLACE STONE TO THE LINES AND DIMENSIONS SHOWN IN THE PLAN ON A FILTER FABRIC FOUNDATION.
2. KEEP THE CENTER STONE SECTION AT LEAST 9 INCHES BELOW NATURAL GROUND LEVEL WHERE THE DAM
ABUTS THE CHANNEL BANKS.
3. EXTEND STONE AT LEAST 1.5 FEET BEYOND THE DITCH BANK (SEE FACE VIEW) TO KEEP WATER FROM CUTTING
AROUND THE ENDS OF THE CHECK DAM.
4. SET SPACING BETWEEN DAMS TO ASSURE THAT THE ELEVATION AT THE TOP OF THE LOWER DAM IS THE SAME
AS THE TOE ELEVATION OF THE UPPER DAM.
5. PROTECT THE CHANNEL AFTER THE LOWEST CHECK DAM FROM HEAVY FLOW THAT COULD CAUSE EROSION.
6. MAKE SURE THAT THE CHANNEL REACH ABOVE THE MOST UPSTREAM DAM IS STABLE.
7. ENSURE THAT OTHER AREAS OF THE CHANNEL, SUCH AS CULVERT ENTRANCES BELOW THE CHECK DAMS, ARE
NOT SUBJECT TO DAMAGE OR BLOCKAGE FROM DISPLACED STONES.
MAINTENANCE
INSPECT CHECK DAMS AND CHANNELS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH OR GREATER)
RAINFALL EVENT REPAIR IMMEDIATELY. CLEAN OUT SEDIMENT, STRAW, LIMBS, OR OTHER DEBRIS THAT COULD CLOG
THE CHANNEL WHEN NEEDED.
ANTICIPATE SUBMERGENCE AND DEPOSITION ABOVE THE CHECK DAM AND EROSION FROM HIGH FLOWS AROUND THE
EDGES OF THE DAM. CORRECT ALL DAMAGE IMMEDIATELY. IF SIGNIFICANT EROSION OCCURS BETWEEN DAMS,
ADDITIONAL MEASURES CAN BE TAKEN SUCH AS INSTALLING A PROTECTIVE RIPRAP LINER IN THAT PORTION OF
THE CHANNEL (PRACTICE 6.31, RIPRAP-LINE AND PAVED CHANNELS).
REMOVE SEDIMENT ACCUMULATED BEHIND THE DAMS AS NEEDED TO PREVENT DAMAGE TO CHANNEL VEGETATION,
ALLOW THE CHANNEL TO DRAIN THROUGH THE STONE CHECK DAM, AND PREVENT LARGE FLOWS FROM CARRYING
SEDIMENT OVER THE DAM. ADD STONES TO DAMS AS NEEDED TO MAINTAIN DESIGN HEIGHT AND CROSS SECTION.
rP-EC RIP RAP CHECK DAM
13 UPDATED MARCH, 2017
NOT TO SCALE
GEOTEXTILE
FILTER FABRIC
R" 4 r7
GEOTEXTILE FILTER BAG SIZED
FOR PUMP DISCHARGE
(MIN. 10'X15')
GEOTEXTILE
FILTER FABRIC
6" #57 STONE
SEWN -IN PIPE
DISCHARGE SLEEVE
3" MIN.
PUMP DISCHARGE
HOSE
NT POINT
DISCHARGE
ATTACHMENT POINT
FOR PUMP DISCHARGE
PUMP DISCHARGE
HOSE
INSTALL ON LESS
THAN5% SLOPE
SECTION
NOTES: UNDISTURBED EARTH
1. FILTER BAG SHALL BE CONSTRUCTED OF NON -WOVEN FILTER FABRIC WITH A MIN. 8 OZ/SQUARE
YARD WEIGHT
2. FILTER BAG FABRIC SHALL HAVE A FLOW RATE OF 80 GPM/S.F. OR SIZED FOR PUMP DISCHARGE
3. SILT BAG SHALL HAVE SLEEVE SEWN -IN SLEEVE FOR RECEIVING THE PUMP DISCHARGE AND PUMP
HOSE SHALL BE SECURELY ATTACHED TO SILT BAG
4. SILT BAG SHALL BE REPLACED WHEN HALF FULL OR PUMP DISCHARGE RATE IS REDUCED ENOUGH
TO CAUSE OVERFLOW. CONTRACTOR SHALL PROVIDE ADDITIONAL BAGS AS REQUIRED.
5. BOTH FILTER BAG AND SILT WITHIN SHALL BE DISPOSED OF IN A PROPER MANNER AFTER
MATERIAL INSIDE IS DRY, RESULTING IN NO DISCHARGE TO THE STREAM
rE C DEWATERING SILT BAG
29 UPDATED MARCH, 2017
NOT TO SCALE
PIPE OUTLET TO FLAT AREA -
NO WELL DEFINED CHANNEL
3do
p
PLAN PLAN
Lam
r\i
d
SECTION A -A
NOTES:
1. La IS THE LENGTH OF THE RIPRAP APRON
2. d= 1.5 TIMES THE MAXIMUM STONE DIAMETER BUT NOT
LESS THAN 6". SECTION B-B
3. IN A WELL-DEFINED CHANNEL EXTEND THE APRON UP THE
CHANNEL BANKS TO AN ELEVATION OF 6" ABOVE THE
MAXIMUM TAILWATER DEPTH OR TO THE TOP OF THE BANK,
WHICHEVER IS LESS.
4. FILTER FABRIC SHOULD BE INSTALLED BETWEEN THE RIPRAP
AND SOIL FOUNDATION.
5. REFERENCE NCDENR LAND QUALITY SECTION DESIGN
MANUAL: 6.41.
CONSTRUCTION SPECIFICATIONS
1. ENSURE THAT THE SUBGRADE FOR THE FILTER AND RIPRAP FOLLOWS THE REQUIRED LINES AND GRADES SHOWN IN THE
PLAN. COMPACT ANY FILL REQUIRED IN THE SUBGRADE TO THE DENSITY OF THE SURROUNDING UNDISTURBED MATERIAL.
LOW AREAS IN THE SUBGRADE ON UNDISTURBED SOIL MAY ALSO BE FILLED BY INCREASING THE RIPRAP THICKNESS.
2. THE RIPRAP AND GRAVEL FILTER MUST CONFORM TO THE SPECIFIED GRADING LIMITS SHOWN ON THE PLANS.
3. FILTER CLOTH, WHEN USED, MUST MEET DESIGN REQUIREMENTS AND BE PROPERLY PROTECTED FROM PUNCHING OR
TEARING DURING INSTALLATION. REPAIR ANY DAMAGE BY REMOVING THE RIPRAP AND PLACING ANOTHER PIECE OF
FILTER CLOTH OVER THE DAMAGED AREA. ALL CONNECTING JOINTS SHOULD OVERLAP SO THE TOP LAYER IS ABOVE
THE DOWNSTREAM LAYER A MINIMUM OF 1 FOOT. IF THE DAMAGE IS EXTENSIVE, REPLACE THE ENTIRE FILTER CLOTH.
4. RIPRAP MAY BE PLACED BY EQUIPMENT, BUT TAKE CARE TO AVOID DAMAGING THE FILTER.
5. THE MINIMUM THICKNESS OF THE RIPRAP SHOULD BE 1.5 TIMES THE MAXIMUM STONE DIAMETER.
6. RIPRAP MAY BE FIELD STONE OR ROUGH QUARRY STONE. IT SHOULD BE HARD, ANGULAR, HIGHLY WEATHER -RESISTANT
AND WELL GRADED.
7. CONSTRUCT THE APRON ON ZERO GRADE WITH NO OVERFILL AT THE END. MAKE THE TOP OF THE RIPRAP AT THE
DOWNSTREAM END LEVEL WITH THE RECEIVING AREA OR SLIGHTLY BELOW IT.
8. ENSURE THAT THE APRON IS PROPERLY ALIGNED WITH THE RECEIVING STREAM AND PREFERABLY STRAIGHT
THROUGHOUT ITS LENGTH. IF A CURVE IS NEEDED TO FIT SITE CONDITIONS, PLACE IT IN THE UPPER SECTION OF THE
APRON.
9. IMMEDIATELY AFTER CONSTRUCTION, STABILIZE ALL DISTURBED AREAS WITH VEGETATION (PRACTICES 6.10, TEMPORARY
SEEDING, AND 6.11, PERMANENT SEEDING).
MAINTENANCE
INSPECT RIPRAP OUTLET STRUCTURES WEEKLY AND AFTER SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL EVENTS TO
SEE IF ANY EROSION AROUND OR BELOW THE RIPRAP HAS TAKEN PLACE, OR IF STONES HAVE BEEN DISLODGED.
IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE.
RIPRAP APRON SIZING (PER FIG. 8.06a)
OUTLET
PIPE DIAMETER
3 x Do
APRON LENGTH
APRON WIDTH
RIPRAP SIZE
No.
(Do)
(La)
(W=Do+La)
(d50xTHICKNESS)
ALL PIPES
24"
6'
10'
12
8"
-EC PIPE OUTLET PROTECTION
17 UPDATED MARCH, 2017
NOT TO SCALE
4' MAX
8' MAX FOR STD.
STRENGTH FABRIC
LL YLL I\1 I11 L/IJ 111YV
GROUND
NOTE: ALL SILT FENCE NOTES APPLY TO SILT FENCE OUTLET
CONSTRUCTION SPECIFICATIONS
1. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR EXTRA STRENGTH SYNTHETIC FILTER
FABRICS.
2. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED 24 INCHES ABOVE THE GROUND
SURFACE. (HIGHER FENCES MAY IMPOUND VOLUMES OF WATER SUFFICIENT TO CAUSE FAILURE OF THE
STRUCTURE.)
3. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO
AVOID JOINTS. WHEN JOINTS ARE NECESSARY, SECURELY FASTEN THE FILTER CLOTH ONLY AT A SUPPORT
POST WITH 4 FEET MINIMUM OVERLAP TO THE NEXT POST.
4. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED SECURELY TO THE UPSLOPE SIDE
OF THE POSTS. EXTEND THE WIRE MESH SUPPORT TO THE BOTTOM OF THE TRENCH. FASTEN THE WIRE
REINFORCEMENT, THEN FABRIC ON THE UPSLOPE SIDE OF THE FENCE POST. WIRE OR PLASTIC ZIP TIES
SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH.
5. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM OF 8 FEET APART. SUPPORT
POSTS SHOULD BE DRIVEN SECURELY INTO THE GROUND A MINIMUM OF 24 INCHES.
6. EXTRA STRENGTH FILTER FABRIC WITH 6 FEET POST SPACING DOES NOT REQUIRE WIRE MESH SUPPORT
FENCE. SECURELY FASTEN THE FILTER FABRIC DIRECTLY TO POSTS. WIRE OR PLASTIC ZIP TIES SHOULD
HAVE MINIMUM 50 POUND TENSILE STRENGTH.
7. EXCAVATE A TRENCH APPROXIMATELY 4 INCHES WIDE AND 8 INCHES DEEP ALONG THE PROPOSED LINE OF
POSTS AND UPSLOPE FROM THE BARRIER (FIGURE 6.62A).
8. PLACE 12 INCHES OF THE FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH.
9. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND COMPACT. THOROUGH
COMPACTION OF THE BACKFILL IS CRITICAL TO SILT FENCE PERFORMANCE.
10. DO NOT ATTACH FILTER FABRIC TO EXISTING TREES.
MAINTENANCE
INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED
REPAIRS IMMEDIATELY. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME
INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE
STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID
UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT
DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS
BEEN PROPERLY STABILIZED.
FIE
rP-ECSILT FENCE - OUTLET
E C
2 UPDATED MARCH, 2017
NOT TO SCALE
A
B CRITICAL POINTS
/\\ C A OVERLAPS AND SEAMS
SEE TABLE B. PROJECTED WATER LINE
2 2 \�\\ ` / __ __ C. CHANNEL BOTTOM/SIDE
6 SLOPE VERTICES
15 cm
LONGITUDINAL ANCHOR TRENCH
\,�\/\/ / / /�/ram/r//�\/r\\,• (USE WHERE NEEDED)
SECTION VIEW NOTES.
1. HORIZONTAL STAPLE SPACING SHOULD BE
ALTERED IF NECESSARY TO ALLOW STAPLES
TO SECURE THE CRITICAL POINTS ALONG THE
CHANNEL SURFACE.
12"
(15 CM)
6"
(15 cm)
2"-5"
(5cm-12.5cm)
(15 cm
CONSTRUCTION SPECIFICATIONS
1. PREPARE SOIL BEFORE INSTALLING ROLLED EROSION CONTROL PRODUCTS (RECP'S), INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED.
2. BEGIN AT THE TOP OF THE CHANNEL BY ANCHORING THE RECP'S IN A 12" DEEP X 6" WIDE TRENCH WITH APPROXIMATELY 12" OF RECP'S EXTENDED BEYOND THE UP -SLOPE
PORTION OF THE TRENCH. ANCHOR THE RECP'S WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT THE
TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING 12" PORTION OF RECP'S BACK OVER SEED AND COMPACTED SOIL. SECURE RECP'S OVER
COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12" APART ACROSS THE WIDTH OF THE RECP'S.
3. ROLL CENTER RECP'S IN DIRECTION OF WATER FLOW IN BOTTOM OF CHANNEL. RECP'S WILL UNROLL WITH APPROXIMATE SIDE AGAINST THE SOIL SURFACE. ALL
RECP'S MUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES/STAKES PER MANUFACTURER'S RECOMMENDATIONS.
4. PLACE CONSECUTIVE RECP'S END OVER END WITH A 4" - 6" OVERLAP. USE A DOUBLE ROW OF STAPLES STAGGERED 4" APART AND 4" ON CENTER TO SECURE RECP'S
5. FULL LENGTH EDGE OF RECP'S AT TOP OF SIDE SLOPES MUST BE ANCHORED WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" APART IN A 6" DEEP X 6"
WIDE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING.
6. ADJACENT RECP'S MUST BE OVERLAPPED APPROXIMATELY 2" - 5" (DEPENDING ON TYPE) AND STAPLED.
7. IN HIGH FLOW CHANNEL APPLICATIONS, A STAPLE CHECK IS RECOMMENDED AT 30 TO 40 FOOT INTERVALS. USE A DOUBLE ROW OF STAPES STAGGERED 4" APART
AND 4" ON CENTER OVER ENTIRE WIDTH OF CHANNEL.
8. THE TERMINAL END OF THE RECP'S MUST BE ANCHORED WITH A ROW OF STAPLE/STAKES APPROXIMATELY 12" APART IN A 6" DEEP X 6" WIDE TRENCH. BACKFILL
AND COMPACT THE TRENCH AFTER STAPLING.
9. IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR STAKE LENGTHS GREATER THAN 6" MAY BE NECESSARY TO PROPERLY SECURE THE RECP'S.
10. SEE SCHEDULE FOR PRODUCT TYPES.
11. PRESS ENDS OF MATTING 4" INTO GROUND AROUND STRUCTURES AND STAPLE SECURELY.
MAINTENANCE
INSPECT ALL MULCHES PERIODICALLY, AND AFTER RAINSTORMS TO CHECK FOR SOIL EROSION, DISLOCATION OR FAILURE. WHERE EROSION IS OBSERVED, APPLY ADDITIONAL
MULCH. IF WASHOUT OCCURS, REPAIR THE SLOPE GRADE, RESEED AND REINSTALL MULCH. CONTINUE INSPECTIONS UNTIL VEGETATION IS FIRMLY ESTABLISHED.
P-EC SWALE MATTING INSTALLATION
Pr- E C
10 UPDATED MARCH, 2017
NOT TO SCALE
WIRE -
FENCE
24"
_1
STEEL
POST
•
■■■■■■■■■NONE r■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii00;
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
-------------------------------------
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
18" TO 24"
8" DOWN & 4"
FORWARD ALONG
THE TRENCH
WIRE SECTION VIEW
FENCE
FILTER
FABRIC
BACKFILL TRENCH
AND COMPACT
THOROUGHLY
NOTES:
1. FILTER BARRIERS SHALL BE INSPECTED IMMEDIATELY AFTER
EACH RAINFALL AND DAILY DURING PROLONGED RAINFALL.
REPAIRS SHALL BE MADE AS NECESSARY.
2. FABRIC SHALL BE REPLACED PROMPTLY IF FOUND TO BE IN
DISREPAIR.
3. SEDIMENT DEPOSITS SHALL BE REMOVED AFTER EACH STORM
EVENT AND WHEN DEPOSITS REACH APPROXIMATELY 1/3
HEIGHT OF BARRIER.
4. REFERENCE NCDENR LAND QUALITY SECTION DESIGN MANUAL:
6.62.
PLASTIC OR
,,,'WIRE TIES
CONSTRUCTION SPECIFICATIONS
1. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR EXTRA
STRENGTH SYNTHETIC FILTER FABRICS.
2. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED
24 INCHES ABOVE THE GROUND SURFACE. (HIGHER FENCES MAY IMPOUND
EXISTING
VOLUMES OF WATER SUFFICIENT TO CAUSE FAILURE OF THE STRUCTURE.)
GRADE
3. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE
LENGTH OF THE BARRIER TO AVOID JOINTS. WHEN JOINTS ARE NECESSARY,
SECURELY FASTEN THE FILTER CLOTH ONLY AT A SUPPORT POST WITH 4
FEET MINIMUM OVERLAP TO THE NEXT POST.
4. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED
EXISTING
SECURELY TO THE UPSLOPE SIDE OF THE POSTS. EXTEND THE WIRE MESH
GROUND
SUPPORT TO THE BOTTOM OF THE TRENCH. FASTEN THE WIRE
REINFORCEMENT, THEN FABRIC ON THE UPSLOPE SIDE OF THE FENCE POST.
WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE
STRENGTH.
5. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A
MAXIMUM OF 8 FEET APART. SUPPORT POSTS SHOULD BE DRIVEN
SECURELY INTO THE GROUND A MINIMUM OF 24 INCHES.
6. EXTRA STRENGTH FILTER FABRIC WITH 6 FEET POST SPACING DOES NOT
REQUIRE WIRE MESH SUPPORT FENCE. SECURELY FASTEN THE FILTER
EXISTING
FABRIC DIRECTLY TO POSTS. WIRE OR PLASTIC ZIP TIES SHOULD HAVE
GROUND
MINIMUM 50 POUND TENSILE STRENGTH.
7. EXCAVATE A TRENCH APPROXIMATELY 4 INCHES WIDE AND 8 INCHES
DEEP ALONG THE PROPOSED LINE OF POSTS AND UPSLOPE FROM THE
BARRIER (FIGURE 6.62A).
8. PLACE 12 INCHES OF THE FABRIC ALONG THE BOTTOM AND SIDE OF
_
THE TRENCH.
9. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND
- 4"MIN. ����\ UPSLOPE FEONMPACT. THOROUGH CE PERFORMANCE. COMPACTION OF THE BACKFILL IS CRITICAL TO SILT
(DISTURBED /
8 " REA) 10. DO NOT ATTACH FILTER FABRIC TO EXISTING TREES.
MIN.
SLOPE SLOPE LENGTH(FT) MAXIMUM AREA(SQFT)
<2% 100 10,000
2 TO 5% 75 7,500
5 TO 10% 50 5,000
10 TO 20% 25 2,500
>20% 15 1,500
MAINTENANCE
INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH
RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. SHOULD THE
FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME
INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS AS
NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN
AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID
UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL FENCING
MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO
GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS
BEEN PROPERLY
STABILIZED.
rP-EC SILT FENCE PLAN
1 SYMBOL
UPDATED MARCH, 2017
NOT TO SCALE
DocuSigned by:
gEFORF y CHATHAM-RANDOLPH MEGASITE SHEET
5274���®°ARo� oG SEWER SYSTEM EXTENSION NOT TO SCALE
5 Regional Circle o ° MESS/off,°°�ti Q� o�
Suite zaQ� 9<�� = • �' MISCELLANEOUS DETAILS
% SEAL a
Pinehurst, NC 28374 o a 034999 oti ` • o TOWN OF SILER CITYOFFICE MANAGER DESIGNER
910.295.3159 = -v
°°°,yC=504
'.TV `fy k,� D. HONEYCUTT D. HONEYCUTT
NC Firm License # C-0459 /O�°c!NQa� ,c' �'
y\ `� �� PROJECT MANAGER REVIEWER DATE PROJECT # FUNDING #
mcgillassociates.com ��'���;�HONE���` ��GGING QP 1 03/14/23 DLH NCDMLR COMMENTS CHATHAM COUNTY' NORTH CAROLINA
5/25/2023 NO. DATE BY DESCRIPTION D. HONEYCUTT DECEMBER 2022 13.04039 N/A
U
o'
w
J
U)
U_
O
z
O
I-
z
0
U)
z
w
x
w
w
I-
U)
U)
Of
w
w
U)
w
I_
co
Q
c�
w
D-
0
0
z
Q
D_
Q
Q
U
M
0
v
0
r2
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1 D35736
NATURAL
GROUND-
4' MIN.
2'
NATURAL
GROUND
TEMP. 18" CMP
FOR STREAM FLOW
SECTION AA
6" OF #57
1WASHED STONE
10'
2
1 EXCAVATED
`1 MATERIAL
FILTER FABRIC—'
CLASS B RIPRAP (REMOVE AFTER
CONSTRUCTION OR REUSE FOR
STREAM BANK STABILIZATION)
SECTION BB
X —EXTEND FILTER FABRIC
12" INTO CHANNEL BANK
\� CLASS B RIPRAP
(18" MINIMUM THICKNESS)
FILTER FABRIC BLANKET
(MIRAFI 140N OR APPROVED EQUAL)
qCH1 WID
VA IES
TEMP. 18" CMP
FOR STREAM FLOW
SANDBAGS
-r FSTREAM
BED
PROPOSED
WATER OR SEWER LINE
TOP STREAM BANK
B
SANDBAGS
LLJ
TEMP. 18" CMP
NOTE: STABILIZE STREAM BANK PER FOR STREAM FLOW
DETAIL AFTER PIPE INSTALLATION
2
H
w
Z jLii
---
Elf FLOW
PROPOSED
6" OF #57 I WATER OR SEWER
LINE
WASHED STONE
�I I RIPRAP DAM
i
A
A
PLAN
NOTE: ALL DISCHARGE FROM DE —WATERING THE WORK
AREA SHALL BE PUMPED TO EITHER A TEMPORARY
SEDIMENT TRAP OR DE —WATERING SILT BAG PER DETAILS
EC CREEK CROSSING - SMALL
33.) UPDATED MARCH, 2017
NOT TO SCALE
NEW SHEET ADDED
mcg
5 Regional Circle
Suite A
Pinehurst, NC 28374
910.295.3159
NC Firm License # C-0459
mcgillassociates.com
—52740Z01`\A#B e oo' O
0 0.
oF ESS/pia,%
90 .
% SEAL a
O oQ 034999 ti
o�
-70.
0- CIN E
a.aa.aoa
. E
'1, 0
4HON \\
l i i l l"0\\
5/25/2023
SAN
rg
r-
UPON REMOVAL OF
CROSSING STRUCTURES AND
IMMEDIATELY INSTALL
MATTING (NO BACKIN
DISTURBED AREAS OF CREEK
SLOPES, OVERLAP MATTIN
OF 2' TO ADJ
NON —DISTURBED AREAS. D
MAT CREEK B
6" OF
WASHE
TOP STREAM BANK
REMOVE SANDBAGS
Q
. .
•
wow`,►
•
►♦
11
tj
��►`
���
•
rmy,vilimm,
TEMP. 18"
STREAM
PON
ION OF
IPE
ION
INSTALLATION IS
LETE BACKFILL
CH IMMEDIATELY
TE: BOTTOM OF
AM BED SHALL
ESTORED TO THE
cINAL ELEVATION
-TELY REMOVE
C ASSOCIATED
AM
En CREEK BANK RESTORATION DETAIL
36UPDATED MARCH, 2017
NOT TO SCALE
SECTION A —A
NOT TO SCALE
O O O
PLAN VIEW
NOT TO SCALE
TYPE "BELOW GRADE"
1 03/14/23 DLH
NO. DATE BY
(SEE TRENCHING DETAIL)
NOTES:
1. THIS DETAIL SHALL BE USED WHERE NOTED ON THE PLANS OR
ANYWHERE SEPARATION BETWEEN THE SEWER OR WATER LINE
AND STREAM IS LESS THAN 25 FEET.
2. SILT FENCE IN THESE AREAS SHALL BE INSTALLED PRIOR TO
BEGINNING EXCAVATION FOR THE PROPOSED LINE.
3. EXCAVATED MATERIAL SHALL BE PLACED ON SIDE OF TRENCH
AWAY FROM STREAM.
4. STREAM PROTECTION AREA SHALL BE SEEDED IMMEDIATELY
AFTER INSTALLATION OF PROPOSED LINE.
5. SILT FENCE SHALL BE MAINTAINED UNTIL VEGETATIVE COVER IS
ESTABLISHED.
EC\STREAM BANK PROTECTION -EXCAVATION
38UPDATED MARCH, 2017
NOT TO SCALE
PLYWOOD
PAINTED WHITE
lal io'i
II ��
CONCRETE
STAPLES EARTHEN BERM PERMEABLE LAG SCREWS LETTERS
GEOTEXTILE i WASHOUT
—�\\ .� FABRIC I°I
WOOD POST �
SECTION B-B
NOT TO SCALE
0
EARTHEN
0 BERM �
NOTES
1. ACTUAL LAYOUT DETERMINED IN THE FIELD.
2. SIGNAGE IDENTIFYING THE CONCRETE WASHOUT
AREA SHALL BE INSTALLED WITHIN 5FT.OF THE
WASHOUT FACILITY.
OEROSION CONTROL PLAN LEGEND:
CONCRETE CONCRETE WASHOUT
WASHOUT
TEC CONCRETE WASHOUT
11 UPDATED MARCH, 2017
NOT TO SCALE
NCDMLR COMMENTS
DESCRIPTION
CONCRETE WASHOUT SIGN
(OR EQUIVALENT)
PERMEABLw
VGEOTEXTILE_�m
of
FABRIC of
>
VARIABLE
PLAN VIEW
NOT TO SCALE
TYPE "ABOVE GRADE"
WITH EARTHEN BERMS
CHATHAM-RANDOLPH MEGASITE
SEWER SYSTEM EXTENSION
TOWN OF SILER CITY
CHATHAM COUNTY, NORTH CAROLINA
STABILIZED
CONSTRUCTION
ENTRANCE
SELECT FILL/
STONE
FUEL STORAGE TEMPORARY
SPOILS
EARTHEN BERM STORAGE
SILT FENCE
PRIMARY SILT
FENCE AROUND
STOCKPILES
(TYP.)
0
_J
J_
CO
L_
0
z
0
H
z
O
0
z
w
1—
x
w
w
C)
w
w
M
M
NOTES:
0
1. SITE TO BE ESTABLISHED TO PREVENT TRANSPORT OF SEDIMENTS/ CONTAMINANTS
FROM SITE.
2. FUEL STORAGE AREA TO COMPLY WITH SPCC REQUIREMENTS FOR PETROLEUM/
OILS/ LUBRICANTS (POL) STORAGE.
3. CONTRACTOR SHALL MONITOR BMP'S ON A WEEKLY BASIS AND FOLLOWING
SIGNIFICANT STORM EVENTS; MAKING REPAIRS AND/ OR PROVIDING ADDITIONAL
BMP'S AS WARRANTED.
-EC LAYDOWN / STORAGE YARD
47 / UPDATED MARCH, 2017
NOT TO SCALE
3' min.
oQ° Sto ger joints NOTE
Direction of e\ Install wattles snugly into trench.
Existing ground \\ typical)
runoff Abut tightly to adjacent wattle, end 1. Drive states of each end and at 4' spacing
to end, without overlapping the ends until wattle is secured to slope. Do not crush
wattle while staking. Live stakes may be used
for permanent installations.
ELEVATION 2. Use drainage ditch installation only in low flow
conditions.
I Existing ground
I e
o `'° yQG otti Excavate trench 2"
3" to 5" larger than wattle
3' min. Or 4 is. I q FLOW
specified in plans w y1 STEP 1: EXCAVATE TRENCH
o I a O AND INSTALL WATTLES
° f STAKES REQUIRED
i2 p Wattle tlength for Stakes eachewatee
Sediment wattle ackfilled and com acted
o I soil to ground level 25 1 8
Install wattles / 20
tion of runoff 6
along contours / Direc 12 4
n Runoff from I — / frOT disturbed areas
disturbed areas I /
INSTALLATION ALONG SLOPES
I '
STEP 2: BACKFILL SOIL AGAINST WATTLES
I
PLAN
INSTALLATION BEYOND TOE OF SLOPE PROPERLY STAKED AND ENTRENCHED WATTLE
M
WATTLE SPACING
Slope
Spacing
ft.
1:4 of flatter
40
1:3
30
1:2
20
1:1
10
e
N
Provide sufficient length to prevent Stake and entrench wattle FLOW
water from slowing around the wattle I
+I Sediment wattle
N c Slope
0 0 0 o F
/ 'yy'���1"X1" Wood stake
I" II
WATTLE STAKING DETAIL
ELEVATION PLAN
DRAINAGE DITCH INSTALLATION
WATTLE INSTALLATION AND
MAINTENANCE NOTES
1. STRAW ROLL INSTALLATION REQUIRES PLACEMENT
AND SECURE STAKING OF THE ROLL ALONG THE
CONTOUR. RUNOFF MUST NOT BE ALLOWED TO RUN
UNDER OR AROUND THE ROLL.
2. IF WOODEN STAKES CAN NOT BE USED BECAUSE OF
ROCK, THEN RE —BAR MAY BE USED. BE SURE TO
REMOVED RE —BAR WHEN WATTLES ARE REMOVED.
3. ABUT ADJACENT ROLL TIGHTLY END TO END (DO NOT
OVERLAP).
4. DO NOT CRUSH WATTLE WHILE STAKING.
5. REPLACE WATTLE ONCE SATURATED WITH SEDIMENT.
NOT TO SCALE
NOTE DETAIL OBTAINED BY
INTERNET U.S.D.O.T.
EC SEDIMENT WATTLE DETAIL
22 UPDATED MARCH, 2017
NOT TO SCALE
MISCELLANEOUS DETAILS
OFFICE MANAGER DESIGNER
D. HONEYCUTT D. HONEYCUTT
PROJECT MANAGER REVIEWER DATE PROJECT # FUNDING #
D. HONEYCUTT DECEMBER 2022 13.04039 N/A
SHEE
C=505
DocuSign Envelope ID: 4BCB82CF-3B74-4F21-82F7-A39EA1D35736
590
590
u
L
C
585
580
575
570
565
560
555
550
545
9+40
EXISTING WATERWAY GRADE ELEVATION
2:1 EXCAVATION _"'_� \
SLOPE (TYP.)
TRENCH BACKFILL SHALL BE
COMPACTED TO 100% (PER
NCDOT DIVISION 3 SECTION
300 SPECIFICATIONS)
18" CLASS B RIPRAP
PROPOSED GRADE 1.3:1
8" CABC
PROPOSED 45 LF DOUBLE BARREL 6'H X 11'W
9+60 9+80 10+00
5 0 2.5 5 10
GRAPHIC SCALE DIVISION VALUE = 5 FEET
1' MIN.
8" C.A.B.C. IN TWO 4" COMPACTED LIFTS
COMPACTED TO 100% COMPACTION — STANDARD
2:1 EXCAVATION
SLOPE (TYP.)
Al
INVERTS AS SHOWN
NEW SHEET ADDED ON PLANS
PIPE
O.D.
UNDISTURBED EARTH
TYPICAL PAVEMENT REPAIRS
NOT TO SCALE
THIS DETAIL HAS BEEN MODIFIED FOR USE ON THIS PROJECT
4" CON RETE DITCH LINING
EMBED 2" INTO EXISTING GROUND
PROPOSED GRADE 1.3:1
10+20
10+40
585
580
575
570
565
560
555
550
545
10+60
Z
TOP OF FILL
TOP OF FILL TOP OF FILL
0
CO
H }
Q
GROUND LINE H GROUND LINE
H GROUND LINE H
CCD
LL.
J O_-4 Z
00ct)=
< Z
ut=m_a_u= _=u_,u�,,,_ in=ui_ai_u,=
_=m_,u�,,,_ — — — — — —
a� —
_
u n,
COMPACT AFTER
COMPACT AFTER
QUoac0C3
LI-I PIPE IS PLACED
— - — _ — PIPE IS PLACED
LU
O
„ & PRIOR TO i�
PLACEMENT OF
rn i & PRIOR TO
— TYPE 2 PLACEMENT OF
GEOTEXTILE
W J
cc
O H Q
n FILL
ni_r�Fin= in
�
FILL
I.D. /6 MIN. it, n,
NOT LESS
00
z H
~ H
I.D./6 MIN.
I.D./6 MIN. it a=momm_,na„ia ,uan,=n,a THAN 6" q=1°=m_ni=,n=u = 1u=n,=_ni EARTH
NOT LESS THAN 6 O.D. + 3' NOT LESS THAN 6" 1/2" PER FOOT OF
r
r
LU
BUT NOT LESS THAN 12"
ROCK O.D. + 3' NOR MORE THAN 24" O.D.3'
NORMAL EARTH FOUNDATION
_+
ROCK FOUNDATION AS DIRECTED BY ENGR.
UNSUITABLE MATERIAL FOUNDATION
PIPE IN TRENCH
TOP OF FILL
TOP OF FILL TOP OF FILL
------------------
c
~
O
H
H H
LL.
Q
—
J
C
J
GROUND LINE
GROUND LINE
z
H
MIN. O.D. MIN. O.D.
GROUND LINE
— r�� `
MIN. O.D. MIN. O.D. MIN. O.D. N. O.D.
TYPE 2
— — — �•j — GEOTEXTILE — — — jr
y
tY
W
=m-n,=i Hrn_ , -u, T = COMPACT AFTER
— — —PIPE IS PLACED 1
,,
& PRIOR TO _
�—I.D./6 MIN. — — PLACEMENT OF
NOT LESS THAN 6" n_In=nI_ui FILL „�_,n_n =� =u = ,if If
W
COMPACT AFTER O.D. + 2' I.D./6 MIN.
I.D./6 MIN. AS DIRECTED
NOT LESS THAN 6" MIN. O.D. MIN. O.D. BY ENGINEER
z
PIPE IS PLACED NOT LESS THAN 6"
O.D. 2'
Q
a H
& PRIOR TO
%2" PER FOOT OF 'H'
l_
PLACEMENT OF
FILL NORMAL EARTH FOUNDATION
BUT NOT LESS THAN 12"
ROCK FOUNDATION NOR MORE THAN 24"
(n
LL
UNSUITABLE MATERIAL FOUNDATION
PIPE ABOVE GROUND
Q
C
C3
GENERAL NOTES:
DO NOT OPERATE HEAVY EQUIPMENT OVER ANY PIPE CULVERT UNTIL THE PIPE CULVERT HAS
in
Q
I.D. = THE MAXIMUM HORIZONTAL INSIDE DIAMETER DIMENSION.
BEEN PROPERLY BACKFILLED AND COVERED WITH AT LEAST 3 FEET OF APPROVED MATERIAL.
0
�CC
O.D. = THE MAXIMUM HORIZONTAL OUTSIDE DIAMETER DIMENSION.
— - — - — SPRINGLINE OF PIPEUj
H = THE FILL HEIGHT MEASURED VERTICALLY AT ANY POINT
SELECT BACKFILL MATERIAL CLASS III OR CLASS II,
G
ALONG THE PIPE FROM THE TOP OF THE PIPE TO THE TOP
® BELOW SPRINGLINE.
OF THE EMBANKMENT AT THAT POINT.
APPROVED SUITABLE LOCAL MATERIAL ABOVE SPRINGLINE.
TAKE CARE TO FULLY COMPACT HAUNCH ZONE OF PIPE BACKFILL.
„ UNDISTURBED EARTH MATERIAL
LOOSELY PLACED SELECT MATERIAL CLASS III OR CLASS II, TYPE 1
FOR PIPE BEDDING. LEAVE SECTION DIRECTLY BENEATH PIPE
SELECT MATERIAL CLASS V OR VI FOR FOUNDATION CONDITIONING. ENCAPSULATE
SHEET 2 OF 3
UNCOMPACTED AS PIPE SEATING AND BACKFILL WILL
WITH TYPE 2 GEOTEXTILE AS DIRECTED BY THE ENGINEER.
300.01
ACCOMPLISH COMPACTION.
DocuSigned by:
"�A'R,,,, ,�eEFoRF CHATHAM-RANDOLPH MEGASITE 10 5 10 20 SHEET
Y
527�®�ssi°o�''; ,� o� SEWER SYSTEM EXTENSION
5 Regional Circle o0 of o,�°°� o TYPICAL SECTIONS
Suite A CQ , C GRAPHIC SCALE DIVISION VALUE = 10 FEET
PiSEAL o.
NC 28374 - ° 034999 o
= ,
O o o TOWN OF SILER CITYOFFICE MANAGER DESIGNER
910.295.3159 = -v °� N Q
L°°FN ��°°°J y O �, D. HONEYCUTT D. HONEYCUTT C=506
GINS° ° C' ,�
Mcgi NC Firm License # C-0459 - O ° °°°°°°°° � �' �
' , _ \ �\ PROJECT MANAGER REVIEWER DATE PROJECT # FUNDING #
mcgillassociates.com1111100\''',,�;,HoN,,�' ��GGING QP� 3 5/9/23 DLH NCDWI COMMENTS CHATHAM COUNTY NORTH CAROLINA
5/25/2023 NO. DATE BY DESCRIPTION D. HONEYCUTT MAY 2023 13.04039 N/A
I m
co
O
0
co