Loading...
HomeMy WebLinkAboutNCG240016_2023 DMR_20230118 auRG • CR Ty CAROv MECKLENBURG COUNTY Land Use & Environmental Services Agency Solid Waste January 18,2023 DEQ Mooresville Regional Office Attn: DEMLR Stormwater Program 610 East Center Avenue Suite 301 Mooresville,NC 28115 Attention: DEMLR Stormwater Program Subject: Discharge Monitoring Report Mecklenburg County Compost Central—Certificate of Coverage No.NCG240016 Dear Central Files: Please find enclosed the Discharge Monitoring Report,January 2023,for Mecklenburg County Compost Central, a Type I facility located at 5631 West Blvd,North Carolina. If you have any questions,please contact me at 704-318-5523 or by email at Rochelle.rttray@mecklenburgcountync.gov, Sincerely, Rochelle Rattray Solid Waste Environmental Specialist Enclosed: 2023 DMR PEOPLE • PRIDE • PROGRESS • PARTNERSHIP 2145 Suttle Avenue • Charlotte,North Carolina 28208 www.wipeoutwaste.com NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report(DMR) Form for NCG240000 Compost Operations Click here for instructions Complete,sign,scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report(DMR) Upload form within 30 days of receiving sampling results. Mail the original,signed hard copy of the DMR to the appropriate DEMLR Regional Office. Mailed in DMRs must contain an original wet signature. Electronic signatures will not be accepted for mailed in DMRs.This is a requirement until the permittee has registered for eDMR for reporting. Certificate of Coverage No. NCG240016 Person Collecting Samples:Rochelle Rattray Facility Name: Mecklenburg County Compost Central Laboratory Name:Charlotte Water Facility County: Mecklenburg Laboratory Cert. No.: Discharge during this period:®Yes ❑ No (if no,skip to signature and date) Has your facility implemented mandatory Tier response actions for any benchmark exceedances?®Yes ❑ No If so,which Tier(I, II,or Ill)? Tier Ill A copy of this DMR has been uploaded electronically via https://edocs.deq.nc.gov/Forms/SW-DMR®Yes ❑ No Date Uploaded: Analytical Monitoring Requirements for Outfalls with Industrial Activities—Benchmarks in(Red) Parameter Parameter Outfall Outfall Outfall Outfall Outfall Code N/A Receiving Stream Class N/A N/A Date Sample Collected MM/DD/YYYY 1/5/2023 46529 24-Hour Rainfall in inches 1.91 in C0530 TSS in mg/L(100) 28.6 00340 Chemical Oxygen Demand(COD)in mg/L(120) 140 310 Biochemical Oxygen Demand 5-Day (BODS)in mg/L(30) 21.6 61211 Enterococcus in colonies/100mL(500) N/A 31615 Fecal Coliform in colonies per 100 ml (woo) 250000 600 Total Nitrogen in mg/L(30) 5.4 665 Total Phosphorus in mg/L(2) 0.94 400 pH in standard units(Freshwater: 6.0-9.0,Saltwater:6.8-8.5) 6.87 01119 Copper,total recoverable in mg/L (0.010) 0.0082 Non-Polar Oil&Grease in mg/L by EPA <5.0 00552 Method 1664(AGT-HEM)(N/A,but must enter tiered response if exceeds 15) Notes(optional): "I certify by my signature below, under penalty of law,that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system,or those persons directly responsible for gathering the information,the information submitted is,to the best of my knowledge and belief,true,accurate,and complete. I am aware that there are significant penalties for submitting false information,including the possibility of fines and imprisonment for knowing vio ' " t/a/-i Signature of Per ttee or Delegated Authorized Individual Date CHARLOTTE Laboratory Analysis Report WTER Report Date: 01/17/2023 10:52 Environmental Laboratory Services LOCATION: Outfall 2 CHAIN OF CUSTODY#: 230105008 LOC ID: G-COMPCENT1 SAMPLE DATE-TIME: 01/05/2023 11:25 SAMPLE DESCRIPTION: Grab Parameter Result Units RL Method Start Date/Time Analyst Sample ID: A150043 A150043 Chemical Oxygen Demand 140 mg/L 10 HACH 8000 01/09/2023 12:01 CBO A150043 Biochemical Oxygen Demand 21.6 mg/L 2.0 SM5210B-16 01/06/2023 12:30 ASH A150043 Total Suspended Solids 28.6 mg/L 5.0 SM2540D-15 01/06/2023 10:35 CBO A150043 Metals Digestion Completed EPA 200.2 01/06/2023 02:00 KTG A150043 Copper,Total 8.2 ug/L 2.0 EPA 200.7 01/06/2023 18:02 SMH A150043 Hexane Ext Material Silica Gel <5.0 mg/L 5.0 EPA 1664E 01/10/2023 14:38 RCE A150043 Hexane Extractable Material(O&G) <5.0 mg/L 5.0 EPA 1664B 01/10/2023 08:58 RCE A150043 Total Nitrogen(TKN+NOX) 5.4 mg/L 0.25 01/12/2023 22:12 JSB A150043 Total Kjeldahl Nitrogen 3.0 mg/L 0.25 EPA 351.2-93 01/12/2023 22:12 JSB A150043 Total Kjeldahl Nitrogen Digestion Completed EPA 351.2-93 01/12/2023 16:44 JSB A150043 Nitrate/Nitrite 2.4 mg/L 0.10 EPA353.2-93 01/06/2023 13:03 SRP A150043 Total Phosphorus Digestion Completed SM4500P-B(5)-11 01/06/2023 10:25 JSB A150043 Total Phosphorus 0.94 mg/L 0.10 SM4500P-H-11 01/06/2023 14:33 JSB A150043 Fecal Coliform 250000 CFU/100 ml 100 SM9222D-15 01/05/2023 12:53 JPM Comment: 1 __ Gina H. Kimble, Laboratory Supervisor: r--' The resu s contained in this report are specific to the samples listed above. CHARLOTTE WATER-Environmental Laboratory Services 4222 Westmont Drive,Charlotte,North Carolina 28217 N.C.Certification 192, N.C.DHHS Certification 37417, EPA Cert 01215 Page 1 of 1 Facility Name Sample Location Sample Time pH Date Device Used to Sample Mecklenburg County Compost Central Outfall 2 11:25 6.87 1/5/2023 Ysl pH meter CHARLOTTE WATER CHARLOTTE ENVIRONMENTAL LABORATORY SERVICES CHAIN OF CUSTODY RECORD 4222 Westmont Drive,Charlotte,NC 28217 (704)336-2477 or(704)336-2854 � '` }TER COC#: Q\asoo6 PAGE 1 OF 1 CLJENT: Mecklenburg County Send REPORT To: Sampled By(Print Name): LUESA-Solid Waste Amber Grzymski _ FACILITY: Compost �L1 C,Ln Q-i eCsr �Y PROJECT: Compost Central 1 2145 Suttle Ave Witnessed By(Print&Sign Name-If Applicable): Charlotte,NC 28208 PROJECT CODE: FOXHOLE Sample Sample Chemical o Analyses Requested Sample Collection Container Temperature Preservative _,„ v U A z a' B t�i N co Cn Location Code Location Description § a' CT } t; = fl. W # LAB USE ONLY d -5E T v m N E a:-:; j v LAB SAMPLE ID 0 ( o m ~ c o w ~ - m w as p va 0 0 I- -C t\j c a' o to 1 o- v ON j 2 U H U m E bi 5'i p E `° U m m m m O m = _ U tl] m O p °' — m n -... .. o c m O U m Q m o '` o L@ o 0 0 g d m a'i } O O o m- oa ,. N U 1 U U S/1 C? t Q7 U Z 2 Z � 7 J C" It /— V W 7�7_ V G-COMPCENT1 Outfall2 0, \ 1,5 123 N G P 1 N S - `. !]- 1 X X '.500LB 1k G-COMPCENTI Outfall 2 g4 d I) 9 25 N G P 1 0 1 'g'L( X X G-COMPCENTI Outfall 2 PC,t 1 N G P 1 N .. X <2` X C` G-COMPCENTI Outfall 2 L4 N G P 1 0 X X G-COMPCENTI Outfall2 �1L N G GL 2 0 j X C:2 X ) E2 G-COMPCENTI Outfall 2 4 I , I N G P 1 , X 'CT X F G-COMPCENT1 Outfall 2 3-1(2^ `, N G P 1 v X � X I . 0 Comments: Complete all areas shaded in yellow. Blue areas are for LAB USE ONLY, Relinquished by(signature): /" Received ¢nature): / Dale: Time: � 0/,,-'t �� ,�.- //...,-"*Z—s-- 0/-6 -Z3 /2°o Demand ratio-login(COD_BOD)calculation code Relinquished by(Signature): Received by(Signature): Date: Time: `Nutrients include NOX-N,TKN,TP,Total Nitrogen-login(TN)calculation code Sample Type Codes: Container Type Codes Relinquished by(Signature): Received by(Signature): Date: Time: C=Composite P=Plastic B=Bag G=Grab Sample GL=Clear Glass TL=Teflon Lined Cap Relinquished by(Signature): Received by(Signature): Dale: Time: A=Amber Glass VOA=4U ml Glass Vial Rev.7/20/2022 HWC 10 Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form,please visit https://deq.nc.gov/about/divisions/energy-mineral-land- resources/energy-mineral-land-permits/stormwater-permits/npdes-industrial-sw#tab-4 Permit No.: N/C/6 /2/4/ 0/ 0/0/0/ or Certificate of Coverage No.: N/C/G/2/./0/0/1 / 6/ Facility Name: Mecklenburg County-Compost Central County: Mecklenburg Phone No. 704-318-5523 Inspector: Rochelle Rattray Date of Inspection: January 5,2023 Time of Inspection: 11:25 Total Event Precipitation(inches): 1.91 in All permits require qualitative monitoring to be performed during a"measurable storm event." • A"measurable storm event" is a storm event that results in an actual discharge from the permitted site I outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm I interval does not apply if the permittee is able to document that a shorter interval is representative for 1 local storm events during the sampling period,and the permittee obtains approval from the local DEMLR I I Regional Office. By this signature,I certify that this report is accurate and complete to the best of my knowledge: #, --7 (Signature of Permittee or Designee) 1. Outfall Description: Outfall No. 2 Structure(pipe,ditch,etc.): Pipe/Culvert Receiving Stream: Describe the industrial activities that occur within the outfall drainage area: Vehicle maintenance and compositing Page 1 of 2 SWU-242,Last modified 07/28/2017 2. Color: Describe the color of the discharge using basic colors(red,brown,blue,etc.)and tint (light,medium, dark)as descriptors: Light-brown 3. Odor: Describe any distinct odors that the discharge may have(i.e., smells strongly of oil,weak chlorine odor, etc.): Light odor detected. 4. Clarity: Choose the number which best describes the clarity of the discharge,where 1 is clear and 5 is very cloudy: 1 2Q 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge,where 1 is no solids and 5 is the surface covered with floating solids: 1 02 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge,where 1 is no solids and 5 is extremely muddy: 1 20 3 4 5 7. Is there any foam in the stormwater discharge? ®Yes 0 No. Yes 8. Is there an oil sheen in the stormwater discharge? OYes ®No. No 9. Is there evidence of erosion or deposition at the outfall? ®Yes 0 No. Yes 10. Other Obvious Indicators of Stormwater Pollution: List and describe No other indicators. Note: Low clarity,high solids,and/or the presence of foam,oil sheen,or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242,Last modified 07/28/2017 7 CHARLOTTE WATER - Environmental Laboratory Services Sample Receipt Checklist Completed by Initials: Date/Time: CA-0 5.-Z3 / /2c0 COC#: Z 3 C')I SCriR Sample Matrix: 1/astewater EDrinking Water OCrypto/Giardia (LT2) Other: Field Analysis/Information Only(No cooler) Custody Seal(s)Intact?: nYes 0No /A Type of Ice Used: nat Blue Cooler Intact: E'les 0No nN/A [pry IcenNone Shipping Container Intact: nYes nNo nN/A Thermal Preservation: *Sample Temperature measured immediately after removal from cooler. *Notify management immediately of any sample that did not meet temperature requirements or frozen. *If multiple parameters,in additional to BacT are collected for a site,a receipt temperature for the BacT plus another bottle must be measured and recorded on the COC. Requirements: DW: <_6°C WW: <_6°C BacT: _<10°C LT2 Crypto/Giardia: <_20°C LT2 E.coli: 10°C Do sample receipt temperatures meet requirements(including requirement by downward trend)? Ws nNo,explain below. Downward trend required to meet requirement? es *At time of receipt into the laboratory,the allowed downward trend may be applied to meet temperature requirement. Initial temperature from the sample collector becomes critical. If samples are received next day,receipt temperatures must meet requirements listed above. Chemical Preservation: Note:*If samples are not preserved correctly,notify Personnel.Do not check B ci,TOC,VOA,THM and HAA. All containers needing preservation are found to be in EPA compliance? Yes nNo nN/A If no,explain. *If the pH of a metals(excluding Hg)is incorrect,these steps are followed: *If the pH of any other chemically preserved sample is incorrect 1.On COC,document sample pH prior to adding additional preservative. (not including metals),follow these steps: 2.Document"pH NOT MET"on container. 1.Notify immediately of sample incorrectly preserved. Qualify Date/time of preservation will be captured on the lid,when additional sample not properly preserved on the COC and in LIMS. HNO3 Acid is added to achieve pH<2. No comment in LIMS required. Option:Substitute a correctly preserved bottle.Document on COC&notify personnel. Write"DO NOT USE"on the incorrectly preserved bottle. No comment in LIMS requires when a sample with correct preservative is substituted. COC Properly Filled Out? es E No If no,explain. COC Correction sent to Project Manager? Yes E No DNA Do sample labels agree with the COC? n)s nNo If no,explain. All sample bottles accounted for? n�es E No Samples Arrived within Hold Time? es No,&notify Project Mgr. Correct Bottles Used? es 0 No VOA Vials have Zero Headspace(<6 mm)?❑Yes ONo JA *Bubbles should be no larger than: If no,notify Laboratory Section Supervisor. Short Hold Analyses(<48 hrs.)? I. es nNo Rush Turn Around Time(TAT)? ['Yes EN-CC- If yes,notify Laboratory Section(s). If yes,notify Project Manager Addition Information/Comments: Preliminary COC Review(Optional): Initials: Date: REC-100 FORM Checklist_Sample_Receipt EFF093022 This printed copy is an UNCONTROLLED copy of the online CONTROLLED document. T t .4. / '''' .. 4 ...., iitip 1 4,04..,' . \;,....., . : �' 1\ ' � Vr1jr. ' III ♦t i L 15-.11.11..r./:":--'''' ,,,41," •I t i �' (fr .i \ illit - : ' ... ., tr.; ...7 .mot ,kt........\,. .H._,....\.......................... .......... . ....i, '1;1;',.'I, . fig-„p 'Ao t ; '4100/4 4i . di ilik ,t /.0444_, 71 N.. 1 14,,- /f. a .•' `t to > s. -' n� r .�q ic --- z f t F .° . +fi • a. 4 . i i i { t i.':- t'i ,._, , . ' r4e .,„, * *.. ,,,..,I , ,' IOW..0w. .:4', ''', .', r, ....r ,.. ';,'-t,...1..'..7A. 1 :. ,. II \ . , „74,6".' . ,:, - .. ''' ,,. ' :Li , ,,, _ g ,,.:,:,, �`'t-� - • *4ir, t 'ter •f� J. I * + F 4 `" fir k r r �. A -� f+