HomeMy WebLinkAboutNCG120108_2022 DMR_20230113 (2) NCDEQ Division of Energy,Mineral and Land Resources
Stormwater Discharge Monitoring Report(DMR)Form for NCG120000 Page 1 of 2
Landfills November 2022
Click here for instructions
Complete,sign,scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report(DMR)Upload form within
30 days of receiving sampling results. Mail the original,signed hard copy of the DMR to the appropriate DEMLR Regional Office.
Certificate of Coverage No. NCG12 0108 Person Collecting Samples: Devitt Kehoe, S&ME, Inc.
Facility Name:Edgecombe County Landfill Laboratory Name: Environment 1, Inc.
Facility County:Edgecombe Laboratory Cert. No.: 591
Discharge during this period:❑✓ Yes ❑No (if no,skip to signature and date)
Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances?❑✓ Yes ❑ No
If so,which Tier(I,II,or III)? III
A copy of this DMR has been uploaded electronically via https://edocs.deq.nc.gov/Forms/SW-DMR 0 Yes ❑ No
Date Uploaded: 1/13/2022
Analytical Monitoring Requirements for Outfalls with Industrial Activities—Benchmarks in(Red)
Parameter Parameter Outfall SDO-1 Outfall SDO-2 Outfall SDO-3 Outfall SDO-4 Outfall SDO-5
Code
N/A Receiving Stream Class Class C Class C Class C Class C Class C
N/A Date Sample Collected MM/DD/YYYY 11/30/2022 11/30/2022 11/30/2022 11/30/2022 11/30/2022
46529 24-Hour Rainfall in inches 0.5" 0.5" 0.5" 0.5" 0.5"
C0530 TSS in mg/L(100 or 50*) 3.2 221 51 11 24
00400 pH in standard units(6.0—9.0) 8.18 8.11 7.68 7.17 7.31
00340 Chemical Oxygen Demand in mg/L <20 159 58 61 58
(120)
31616 Fecal Coliform in#per 100 ml(1000) 2000 >6000 1000 3000 >6000
Additional parameters for outfalls in drainage areas that use>55 gallons per month of new hydraulic oil on average
00552 Non-Polar Oil&Grease in mg/L(15) <5.0 <5.0 <5.0 <5.0 <5.0
NCOIL Estimated New Motor/Hydraulic Oil
Usage in gal/month
*Outfalls to Outstanding Resource Waters(ORW),High Quality Waters(HOW),Trout Waters(Tr)and Primary Nursery Areas(PNA)
have a benchmark TSS limit of 50 mg/L.All other water classifications have a benchmark of 100 mg/L
Notes(optional):
"I certify by my signature below,under penalty of law,that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted.Based on my
inquiry of the person or persons who manage the system,or those persons directly responsible for gathering the information,the information
submitted is,to the best of my knowledge and belief,true,accurate,and complete.I am aware that there are significant penalties for submitting
false information,including the possibility of fines and imprisonment for knowing violations."
Signature of Permitt a or Delegate Authorized Individual Date
g g
Email Address gloriamoseley@edgecombeco.com Phone Number 252-813-3947
NCDEQ Division of Energy, Mineral and Land Resources
Stormwater Discharge Monitoring Report (DMR) Form for NCG120000
Landfills Page 2 of 2
November 2022
Click here for instructions
Complete,sign,scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report(DMR) Upload form within
30 days of receiving sampling results. Mail the original,signed hard copy of the DMR to the appropriate DEMLR Regional Office.
Certificate of Coverage No. NCG12 0108 Person Collecting Samples: Devin Kehoe, S&ME, Inc.
Facility Name:Edgecombe County Landfill Laboratory Name: Environment 1, Inc.
Facility County:Edgecombe Laboratory Cert. No.: 591
Discharge during this period:Q Yes ❑ No (if no,skip to signature and date)
Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? s❑Yes ❑ No
If so,which Tier(I, II,or III)? I I
A copy of this DMR has been uploaded electronically via https://edocs.deq.nc.gov/Forms/SW-DMR 0 Yes ❑No
Date Uploaded: 1/13/2022
Analytical Monitoring Requirements for Outfalls with Industrial Activities—Benchmarks in(Red)
Parameter Parameter Outfall SDO-6A Outfall SDO-6B Outfall Outfall Outfall
Code
N/A Receiving Stream Class Class C Class C
N/A Date Sample Collected MM/DD/YYYY 11/30/2022 11/30/2022
46529 24-Hour Rainfall in inches 0.5" 0.5"
C0530 TSS in mg/L(100 or 50*) <2.5 17
00400 pH in standard units(6.0-9.0) 7.68 7.65
00340 Chemical Oxygen Demand in mg/L 49 61
(120)
31616 Fecal Coliform in#per 100 ml(1000) 764 >6000
Additional parameters for outfalls in drainage areas that use>55 gallons per month of new hydraulic oil on average
00552 Non-Polar Oil&Grease in mg/L(15) <5.0 <5.0
NCOIL Estimated New Motor/Hydraulic Oil
Usage in gal/month
* Outfalls to Outstanding Resource Waters(ORW),High Quality Waters(HQW),Trout Waters(Tr)and Primary Nursery Areas(PNA)
have a benchmark TSS limit of 50 mg/L.All other water classifications have a benchmark of 100 mg/L
Notes(optional):
"I certify by my signature below,under penalty of law,that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my
inquiry of the person or persons who manage the system,or those persons directly responsible for gathering the information,the information
submitted is,to the best of my knowledge and belief,true,accurate,and complete.I am aware that there are significant penalties for submitting
false information,including the possibility of fines and imprisonment for knowing violations."
Signature of Permittee or Delegated Authorized Individual Date
Email Address gloriamoseley@edgecombeco.com Phone Number 252-813-3947