Loading...
HomeMy WebLinkAboutSW8880307_CURRENT PERMIT_19880315STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 S g o3o DOC TYPE ® CURRENT PERMIT ❑ APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE \°\%8 O'�>lS YYYYMMDD • O� SrAho� Wt State of North Carolina Department of Natural Resources and Community Development Wilmington Regional Office James G. Martin, Governor Bob Jamieson S. Thomas Rhodes, Secretary DIVISION OF ENVIRONMENTAL MANAGEMENT March 15, 1988 Mr. Daniel E. Cutler, Vice President Bald Head Island Management, Inc. Post Office Box 10999 Southport, North Carolina 28461 Subject: Determination of Compliance with Stormwater Regulations Project # 880307 Bald Head Island - Ibis Roose Parcel Brunswick County - Dear Cutler'--'- The Wilmington Regional Office received" your Sedimentation and Erosion Control Plan (or Stormwater Management Plan) submittal for the subject project on 11 March 1988. Based on our review of the project documents, we have determined that the project complies with the Stormwater Regulations set forth in Title 15 NCAC 2H.1000. If you have any questions concerning this matter, please contact me at (919) 256-4161. Sine ely, Q A. PrestonJr., P.E. Regional Engineer APH:kc CC: Bill Mills WiRO, CF 7-)25 Wrightsville Avenue, Wilmington, NC. 2W3-3696 • Telephone 919-2564161 An Equal Opportunity Affirmative Action Employer \,4 DIVISION OF ENVIRONMENTAL MANAGEMENT Submittal Form for Projects Using Density Limits for Stormwater Control PROJECT DATA Name of Project: Bald Head Island - Ibis Roost Location (County, Township/Municipality, Address): Brunswick County - Bald Head Island Applicant Name: Bald Head Island Management, Inc... Mailing Address:P. 0. Box 10999 Southooct.L N. C. 28461 Phone No.: 919-457-5000 Submittal Date: March 7 1988 Brief Description (include map and appropriate drawings): -n I.c. 17 RI Water Body Receiving Stormwater Runoff: Name of Water Body: Bald Head Creek - Parcel ;Gg00+/- tt_ from Classification of Water Body:SA Batd Heart creek $1200 +/- from Cape Fear River Total Area of Proposed Project (acres): s.50 State/Federal Permits and Approvals Required: (Check Appropriate Blanks) CAMA Major N/A Sedimendation and Erosion Control x 404 Permit N/A DEM/DHS Sewage Disposal x Other (specify): — N/A CALCULATION OF BUILT -UPON AREA (Built -upon area means that portion of an individual development that is covered by impervious or partially pervious cover including buildings, pavement, recreation 'facilities, etc. but not including decking.) a) Built -upon area: 1.91 AC. b) Total project area: 8�9 % built -upon = built -upon / total project area * 100 % built -upon area = 2 247 If the water body receiving stormwater runoff is classified as SA, is the % built -upon area < 25%? Yes x No If the water body receiving stormwater runoff is classified other than SA, is the % built -upon area < 30%? Yes x No STORMWATER COLLECTION SYSTEM Is the only kind of stormwater collection system grass swales? Yes x No (Grassed -line swales should have a side slope of 3:1 (H:V) or less.) If -no, please provide a detailed description. BUFFER AREA Is the built -upon area at least 30 feet from mean high water of all surface waters? Yes x No If no, please provide a detailed description. (Note: only boat ramps, public roads, public bridges and walkways to water related facilities are allowed within 30 feet of mean high water if the project is intended to meet stormwater control requirements through density limits.) DEED RESTRICTIONS AND PROTECTIVE COVENANTS Do the deed restrictions and protective covenants ensure that subdivisions maintain the development consistent with the plans and specifications approved by the division and include the State as a beneficiary of the restrictions? Yes x No (Include a copy of the restrictions and covenants with this form-) ✓a»/75s C srz dn/O /7 u�4s� 9 /L39 F.'1� 3/ 6aec4e �/iJi7J O /92 �t 3/ sinre�e.ariso ,isxo� 9voovrZ CERTIFICATION I, Daniel E. Cutler , certify that the information included on this submittal form is correct, that the project will be constructed in conformance with this information, and that to, the best of my knowledge, the proposed project complies with the requriement of 15 NCAC 2H.1003 (b). Signature -Owner or Agent Date P. 0. Box 10999, Southport, N. C. 28461 .4ddress If agent, please list owner's name and address below: DIVISION OF ENVIRONMENTAL MANAGEMENT SIGN -OFF Regional Office D to Indiv CC: Applicant/Region/Mills/CF uating Forms r Quality Supervisor Ell SCE ED MAR 1 1 1988 D E M �n20 PROJ 0- - � IBIS ROOST DENSITY COUNT NOTES: There are two types of units to be placed on the Ibis Roost Parcel. Unit A will Nave 1,375 square feet per unit. Unit B will have 1,239 square feet per unit. The main roadway through the site shall be 12'feet wide. All private drives shall be marl and shall be 8 feet wide. All sidewalks shall be raised wood walks with a spacing of 1/2" or more between boards. All decking around the pool and the clubhouse shall be wood decking with a spacing of 1/2". or more between boards TOTAL SITE ACREAGE OF IBIS ROOST .........................8.50 AC 25% of this area is allowed to be impervious (max.) ..... 2.13 AC IMPERVIOUS ARE". CALCULATIONS (1) 14 UNITS @ 1,375 Square Feet per Unit = 19,250 SF 17 UNITS @ 1,239 Square Feet per Unit = 21,063 SF 40,313 SF (2) MAIN ROADWAY 1,710 Linear Feet X 14 Foot Width 23,940 SF (3) GARAGES .31 Units @ 192 Square Feet Ea. 5,952 SF (4) PRIVATE DRIVES @ 8 foot width 9,400 SF (5) CLUBHOUSE AND POOL AREA 3,775 SF TOTAL IMPERVIOUS AREA .........................83,380 SF TOTAL (impervious 22.50%) or 1.91 AC TOTAL