Loading...
HomeMy WebLinkAboutSW8140801_HISTORICAL FILE_20140805I' STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 NLkOS0 1 DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS ® HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 20ly 0905 YYYYMMDD r=Z ft, NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor August 5, 2014 Jason Swain, Manager Shallotte Developers, LLC 1121-P Military Cutoff Road Wilmington, NC 28405 Subject: State Stormwater Management Permit No. SW8 140801 O'Reilly Auto Parts High Density Commercial Wet Detention Pond Project Brunswick County Dear Mr. Swain: John E. Skvarla, III Secretary The Wilmington Regional Office received a complete, Stormwater Management Permit Application for O'Reilly Auto Parts on August 1, 2014. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000 and Session Law 2008-211. We are forwarding Permit No. SW8 140801 dated August 5, 2014, for the construction, operation and maintenance of the BMP's and built -upon areas associated with the subject project. This permit shall be effective from the date of issuance until August 5, 2022, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the conditions listed in this permit regarding the Operation and Maintenance of the BMP(s), recordation of deed restrictions, procedures for changes of ownership, transferring the permit, and renewing the permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system, to record deed restrictions, to transfer the permit, or to renew the permit, will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing by filing a written petition with the Office of Administrative Hearings (OAH). The written petition must conform to Chapter 150B of the North Carolina General Statutes, and must be filed with the OAH within thirty (30) days of receipt of this permit. You should contact the OAH with all questions regarding the filing fee (if a filing fee is required) and/or the details of the filing process at 6714 Mail Service Center, Raleigh, NC 27699-6714, or via telephone at 919-431-3000, or visit their website at www.NCOAH.com, Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact Chris Baker in the Wilmington Regional Office, at (910) 796-7215. Sin rely, c� ?Tracy Davis, P.E., Director Division of Energy, Mineral and Land Resources GDS/csb: G:1WQSIStormwateAPennits & Projects120141140801 HD12014 08 permit 140801 cc: Robert Balland, P. E., Paramounte Engineering, Inc. Brunswick County Building Inspections Brunswick County Engineering Wilmington Regional Office Stormwater File Division of Energy, Mineral, and Land Resources Land Quality Section —Wilmington Regional Office 127 Cardinal Drive Extension, Wilminqton, North Carolina 28405 • (910) 796-7215 / Fax: (910) 350-2004 State Stormwater Management Systems Permit No. SW8 140801 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENERGY, MINERAL AND LAND RESOURCES STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY COMMERCIAL DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Shallotte Developers, LLC O'Reilly Auto Parts 4607 Main Street, Shallotte, Brunswick County FOR THE construction, operation and maintenance of a wet detention pond in compliance with the provisions of 15A NCAC 2H .1000 and Session Law 2008-211 (hereafter collectively referred to as the "stormwater rules') the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division and considered a part of this permit. This permit shall be effective from the date of issuance until August 5, 2022, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described in Section 1.7 of this permit. The stormwater control has been designed to handle the runoff from 69,300 square feet of impervious area. 3. A 50' wide vegetative buffer must be provided and maintained adjacent surface waters, measured horizontally from and perpendicular to the normal pool of impounded structures, the top of bank of both sides of streams and rivers and the mean high water line of tidal waters. 4. The tract will be limited to the amount of built -upon area indicated in this permit, and per approved plans. The built -upon area for the future development is limited to 39,735 square feet. 5. All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements. The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans. 6. The runoff from all built -upon area within the permitted drainage area(s) of this project must be directed into the permitted stormwater control system. Page 2 of 7 State Stormwater Management Systems Permit No. SW8 140801 7. The following design criteria have been provided in the wet detention pond and must be maintained at design condition: a. Drainage Area, ?cres: 2.65 Onsite, ft : 115,283 Offsite, ftz: N/A b. Total Impervious Surfaces, ftz: 69,300 Onsite, ft : 69,300 Offsite, ftz: N/A C. Design Storm, inches: 1.5 d. Average Pond Design Depth, feet: 4.0 e. TSS removal efficiency: 90% f. Permanent Pool Elevation, FMS�: 4.0 9. Permanent Pool Surface Areq, ft : 6,717 h. Permitted Storage Volume, ft : 9,135 i. Temporary Storage Elevation, FMSL: 5.25 j. Pre-dev. 1 yr-24 hr. discharge rate, cfs: 1.09 k. Controlling Orifice: 1.25" 0 pipe I. Orifice flowrate, cfs: 0.03 M. Permitted Forebay Volume, ft3: 3,890 n. Fountain Horsepower N/A o. Receiving Stream/River Basin: Woodward Branch / Lumber P. Stream Index Number: 15-25-2-8 q. Classification of Water Body: "C;Sw:HQW" II. SCHEDULE OF COMPLIANCE 1. The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface. 2. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 3. The permittee shall, at all times, provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The signed and approved Operation and Maintenance Agreement must be followed in its entirety and maintenance must occur at the scheduled intervals. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DENR. The records will indicate the date, activity, name of person performing the work and what actions were taken. 5. This stormwater pond does not contain enough permanent pool volume to be allowed a decorative spray fountain. 6. The facilities shall be constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 7. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. A modification may be required for those deviations. If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. Page 3 of 7 State Stormwater Management Systems Permit No. SW8 140801 9. Access to the stormwater facilities for inspection and maintenance shall be maintained via appropriate recorded easements at all times. 10. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: a. Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc. b. Redesign or addition to the approved amount of built -upon area or to the drainage area. C. Further development, subdivision, acquisition, lease or sale of any, all or part of the project area. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought. d. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. e. The construction of any future BUA listed on the application. 11. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. 12. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. A copy of the approved plans and specifications shall be maintained on file by the Permittee at all times. III. GENERAL CONDITIONS 1. Any individual or entity found to be in noncompliance with the provisions of this storrmwater management permit or the requirements of the Stormwater rules is subject to enforcement procedures as set forth in G.S. 143 Article 21. 2. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal) having jurisdiction. 3. In the event that the facilities fail to perform satisfactorily, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 4. This permit is not transferable to any person or entity except after notice to and approval by the Director. The permittee shall submit a completed and signed Name/Ownership Change Form, accompanied by the supporting documentation as listed on the form, to the Division at least 60 days prior to any one or more of the following events: a. An ownership change including the sale or conveyance of the project area in whole or in part; b. The sale or conveyance of the common areas to a Homeowner's or Property Owner's Association, subject to the requirements of Session Law 2011-256; c. Bankruptcy; d. Foreclosure; e. Dissolution of the partnership or corporate entity; f. A name change of the current permittee; g. A name change of the project; h. A mailing address change of the permittee; Page 4 of 7 State Stormwater Management Systems Permit No. SW8 140801 The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request. 6. The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility. 7. The permit remains in force and effect until modified, revoked, terminated or renewed. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and re -issuance or termination does not stay any permit condition. 8. Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. 9. The permittee shall submit a permit renewal request at least 180 days prior to the expiration date of this permit. The renewal request must include the appropriate documentation and the processing fee. Permit issued this the 5th day of August, 2014. N/O�TK� C�A,ROLIN�NVIjS�LVMENTAL MANAGEMENT COMMISSION /icX/ or -Tracy Da o , P.E., Director/ Division of Energy, Mineral and Land Resources By Authority of the Environmental Management Commission Page 5 of 7 State Stormwater Management Systems Permit No. SW8 140801 O'Reilly Auto Parts Stormwater Permit No. SW8 140801 Brunswick County Designer's Certification I, , as a duly registered in the State of North Carolina, having been authorized to observe (periodically/ weekly/ full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form is included in the Certification. Noted deviations from approved plans and specifications: Signature Registration Number Date SEAL Page 6 of 7 State Stormwater Management Systems Permit No. SW8 140801 Certification Requirements: 1. The drainage area to the system contains approximately the permitted acreage. 2. The drainage area to the system contains no more than the permitted amount of built -upon area. 3. All the built -upon area associated with the project is graded such that the runoff drains to the system. 4. All roof drains are located such that the runoff is directed into the system. 5. The outlet structure elevations are per the approved plan. 6. The outlet structure is located per the approved plans. 7. Trash rack is provided on the outlet structure. 8. All slopes are grassed with permanent vegetation. 9. Vegetated slopes are no steeper than 3:1. 10. The inlets are located per the approved plans and do not cause short-circuiting of the system. 11. The permitted amounts of surface area and/or volume have been provided. 12. Required drawdown devices are correctly sized and located per the approved plans. 13. All required design depths are provided. 14. All required parts of the system are provided, such as a vegetated shelf, and a forebay. 15. The required system dimensions are provided per the approved plans. 16. All components of the stormwater BMP are located in either recorded common areas, or recorded easements. cc: NCDENR-DEMLR Wilmington Regional Office Brunswick County Building Inspections Page 7 of 7 Permit Number: (to be provided by DWQ) Drainage Area Number: Wet Detention Basin Operation and Maintenance Agreement I will keep a maintenance record on this BMP. This maintenance record will be kept in a log in a known set location. Any deficient BMP elements noted in the inspection will be corrected, repaired or replaced immediately. These deficiencies can affect the integrity of structures, safety of the public, and the removal efficiency of the BMP. The wet detention basin system is defined as the wet detention basin, pretreatment including forebays and the vegetated filter if one is provided. This system (check one): does ® does not incorporate a vegetated filter at the outlet. This system (check one): does ® does not incorporate pretreatment other than a forebay. Important maintenance procedures: — Immediately after the wet detention basin is established, the plants on the vegetated shelf and perimeter of the basin should be watered twice weekly if needed, until the plants become established (commonly six weeks). — No portion of the wet detention pond should be fertilized after the first initial fertilization that is required to establish the plants on the vegetated shelf. — Stable groundcover should be maintained in the drainage area to reduce the sediment load to the wet detention basin. — If the basin must be drained for an emergency or to perform maintenance, the flushing of sediment through the emergency drain should be minimized to the maximum extent practical. — Once a year, a dam safety expert should inspect the embankment. After the wet detention pond is established, it should be inspected once a month and within 24 hours after every storm event greater than 1.0 inches (or 1.5 in� es-i pp Coastal County). Records of operation and maintenance should be kept in knoV E location and must be available upon request. QUA 01 2014 Inspection activities shall be performed as follows. Any problems that are and shall be repaired immediately. BMP element: Potential problenu How 1 will remediate theproblem: The entire BMP Trash/debris is present. Remove the trash/debris. The perimeter of the wet Areas of bare soil and/or Regrade the soil if necessary to detention basin erosive gullies have formed. remove the gully, and then plant a ground cover and water until it is established. Provide lime and a one-time fertilizer application. Vegetation is too short or too Maintain vegetation at a height of long. approximately six inches. Form SW401-Wet Detention Basin O&M-Rev.4 Page 1 of 4 Permit Number: (to be provided by DWQ) Drainage Area Number: BMP element: Potential roblem: How I will remediate the roblem: The inlet device: pipe or swale The pipe is clogged. Unclog the pipe. Dispose of the sediment off -site. The pipe is cracked or Replace the pipe. otherwise dama ed. Erosion is occurring in the Regrade the swale if necessary to swale. smooth it over and provide erosion control devices such as reinforced turf matting or riprap to avoid future problems with erosion. The forebay Sediment has accumulated to a depth greater than the original design depth for Search for the source of the sediment and remedy the problem if possible. Remove the sediment and sediment storage. dispose of it in a location where it will not cause impacts to streams or the BMP. Erosion has occurred. Provide additional erosion protection such as reinforced turf matting or riprap if needed to prevent future erosion problems. Weeds are present. Remove the weeds, preferably by hand. If pesticide is used, wipe it on the plants rather than spraying. The vegetated shelf Best professional practices Prune according to best professional show that pruning is needed practices to maintain optimal plant health. Plants are dead, diseased or Determine the source of the dying, problem: soils, hydrology, disease, etc. Remedy the problem and replace plants. Provide a one-time fertilizer application to establish the ground cover if a soil test indicates it is necessary. Weeds are present. Remove the weeds, preferably by hand. If pesticide is used, wipe it on the plants rather than spraying. The main treatment area Sediment has accumulated to a depth greater than the Search for the source of the sediment and remedy the problem if original design sediment possible. Remove the sediment and storage depth. dispose of it in a location where it will not cause impacts to streams or the BMP. Algal growth covers over Consult a professional to remove 50% of the area. and control the algal growth, Cattails, phragmites or other Remove the plants by wiping them invasive plants cover 50% of with pesticide (do not spray). the basin surface. -EIVE Form SW401-Wet Detention Basin O&M-Rev.4 Pi��� ZYage 174 Rv Permit Number: (to be provided by DWQ) Drainage Area Number: BMP element: Potentialproblem: How I will remediate theproblem: The embankment Shrubs have started to grow Remove shrubs immediately. on the embankment. Evidence of muskrat or Use traps to remove muskrats and beaver activity is present. consult a professional to remove beavers. A tree has started to grow on Consult a dam safety specialist to the embankment. remove the tree. An annual inspection by an Make all needed repairs. appropriate professional shows that the embankment needs repair. if applicable) The outlet device Clogging has occurred. Clean out the outlet device. Dispose of the sediment off -site. 'rhe outlet device is damaged Repair or replace the outlet device. The receiving water Erosion or other signs of Contact the local NC Division of damage have occurred at the Water Quality Regional Office, or outlet. the 401 Oversight Unit at 91.9-733- 1786. The measuring device used to determine the sediment elevation shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments. When the permanent pool depth reads 8.0 feet in the main pond, the sediment shall be removed. When the permanent pool depth reads _6.0 feet in the forebay, the sediment shall be removed. BASIN DIAGRAM ill in the blanks) 17 Permanent Pool Elevation 4.0 Sediment Removal .-2.0 Pe anen Pool Volume Sediment Removal Elevation -4.0 Volume Bottom Elevatio -3.0 -ft Min. ---------------------------- - ------------ ------ Sediment Bottom Elevation -5.0 1-ft n. Storage Sediment Storage FOREBAV MAIN POND FECEIVE AUG 01 20A BY:.--- Form SW401-Wet Detention Basin O&M-Rev.4 - Page 3of 4 Permit Number: (m be provided by DWQ) I acknowledge and agree by my signature below that I am responsible for the performance of the maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. Project name: O'Reilly Auto Parts 6MP drainage area number: Print name: Jason D. Swain Title: Authorized Agent Address: 1121 P Military Cutoff Road Wilmington NC 28405 Date: O(o- 11 -'1 OI q Note: The legally responsible party should not be a homeowners association unless more than 50% of the lots have been sold and a resident of the subdivision has been named the president. I, I� on t1A 9 a Notary Public for the State of NDI-`i k a,y-ol:yNOt , County ofA)et) Wa/\ooe [— , do hereby certify that N QS o v1 O S wat r1 personally appeared before me this day of ) (AY)P , 0101 `f , and acknowledge the due execution of the forgoing wet detention basin maintenance requirements. Witness my hand and official seal, A�(/N/ a leSxa'­'�OvL_ 0 apTApY oo• pUBI�G SEAL My commission expires 11122 170 1 8 IFICEOVE01 r AUG 01 2014 Li B e: Form SW40I-Wet Detention Basin O&M-Rev.4 Page 4 of 4 DWQ USE ONLY Date Received Fee Paid Permit Number Applicable Rules: ❑ Coastal SW - 4995 ❑ Coastal SW - 2008 ❑ Ph 11 - Post Construction (select all that apply) ❑ Non -Coastal SW- HQW/ORW Waters ❑ Universal Stormwater Management Plan ❑ Other WQ M>mt Plan: State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form nmq be photocopied for use as apt original I. GENERAL INFORMATION 1. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc.): 2. Location of Project (street address): 4607 Main Street City: Shallotte County: Brunswick Zip:28459 3. Directions to project (from nearest major intersection): From the intersection of US Highway sway 17 (Ocean Flighway) and Main Street (US 17 Business), travel for approximately 1 mile. The project will be on your left at the intersection of Main Street and Hinson Street. 4. Latitude:33° 58' 40" N Longitude:78° 22' 42" W of the main entrance to the project. II. PERMIT INFORMATION: 1. a. Specify whether project is (check one): ®New ❑Modification ❑ Renewal w/ Modificationt tReaernals with miodificatioss also requires SWU-102 — Reneroal Application Ford b.If this application is being submitted as the result of a modification to an existing permit, list the existing permit number , its issue date (if known) , and the status of construction: ❑Not Started ❑Partially Completed* ❑ Completed* °provide a designer's certification 2. Specify the type of project (check one): ❑Low Density ®High Density ❑Drains to an Offsite Stormwater System ❑Other 3. If this application is being submitted as the result of a previously returned application or a letter from DWQ requesting a state stormwater management permit application, list the stormwater project number, if assigned, and the previous name of the project, if different than currently proposed, � Q V 4. a. Additional Project Requirements (check applicable blanks; information on require ate permits Yan obtained by contacting the Customer Service Center at 1-877-623-6748): AUG U ❑CAMA Major ®Sedimentation/Erosion Control: 2.25 Df Disturbed Area ❑NPDES Industrial Stormwater ❑404/401 Permit: Proposed Impacts BY: b.lf any of these permits have already been acquired please provide the Project Name, Project/Permit Number, issue date and the type of each permit: 5. Is the project located within 5 miles of a public airport? ®No ❑Yes If yes, see S.L. 2012-200, Part Vl: http://yortal.ncdenr.orghveb/wq/ws/su/stltcsw/rules laws FormSWU-101 Vcrsion06Au2012 F-,Pteediol6?.n.ni ii-,=;)i ",••� r;ix; r. . III. CONTACT INFORMATION 1. a. Print Applicant / Signing Official's name and title (specifically the developer, property owner, lessee, designated government official, individual, etc. who owns the project): Applicant/Organization: Shallotte Developers, LLC Signing Official & Title: Jason Swain, Manager b.Contact information for person listed in item la above: Street Address:1121-P Military Cutoff Rd. City: State:N.C. Zip:28405 Mailing Address (if applicable): City: State: Zip: Phone: (910 ) 256-2211 Email: jasonOswainassociates.com Fax: (910 ) 256-2171 c. Please check the appropriate box. The applicant listed above is: ® The property owner (Skip to Contact Information, item 3a) ❑ Lessee* (Attach a copy of the lease agreement and complete Contact Information, item 2a and 2b below) ❑ Purchaser* (Attach a copy of the pending sales agreement and complete Contact Information, item 2a and 2b below) ❑ Developer* (Complete Contact Information, item 2a and 2b below.) 2. a. Print Property Owner's name and title below, if you are the lessee, purchaser or developer. (This is the person who owns the property that the project is located on): Property Owner/Organiza Signing Official & Title:_ b. Contact information for person listed in item 2a above: Street Address: Mailing Address (if applicable): Citv: State: Phone: ( ) Fax: ( ) Email: 3. a. (Optional) Print the name and title of another contact such as the project's construction supervisor or other person who can answer questions about the project: Other Contact Person/Organiza Signing Official & b.Contact information for person listed in item 3a above: Mailing Address: Phone: 4. Local jurisdiction for building permits: _ Point of Contact: ', onm"S:WUs101.' Version06Aug2012< Fax: Phone #: Zip: - IV. PROJECT INFORMATION 1. In the space provided below, briefty summarize how the stormwater runoff will be treated. Stormwater will be collected by drop inlets and conveyed to the proposed Het detention facility via closed conduit system. The proposed wet detention facility is designed for the first 1.5" of runoff. 2. a. If claiming vested rights, identify the supporting documents provided and the date they were approved: ❑ Approval of a Site Specific Development Plan or PUD Approval Date: ❑ Valid Building Permit Issued Date: ❑ Other: Date: bAf claiming vested rights, identify the regulation(s) the project has been designed in accordance with: ❑ Coastal SW -1995 ❑ Ph II - Post Construction 3. Stormwater runoff from this project drains to the Lumber River basin. 4. Total Property Area: 2.65 acres 5. Total Coastal Wetlands Area: 0 acres 6. Total Surface Water Area: 0 acres 7. Total Property Area (4) - Total Coastal Wetlands Area (5) - Total Surface Water Area (6) = Total Project Area+:2.65 acres Total project area shall be calculated to exclude the following the normal pool of impounded structures, the area between the banks of streams and rivers, the area belozo the Normal High Water (NHW) line or Mean High Water (MHW) line, and coastal wetlands landward from the NHW (or MHW) line. The resultant project area is used to calculate overall percent built upon area (BUA). Non -coastal wetlands landward of the NHW (or MHW) line may be included in the total project area. 8. Project percent of impervious area: (Total Impervious Area / Total Project Area) X 100 = 60.0 9. How many drainage areas does the project have?7 (For high density, count 1 for each proposed engineered stormwater BMP. For low density and other projects, use 1 for the zolwle property area) 10. Complete the following information for each drainage area identified in Project Information item 9. If there are more than four drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. Basin Information Draina e Area 1 Draina e Area Draina e Area _ Draina e Area _ Receiving Stream Name Woodward Branch Stream Class * C; Sw; HQW Stream Index Number * 15-25-2-8 Total Drainage Area (sf) 115,283 On -site Drainage Area (so 115,283 Off -site Drainage Area (so 0 Proposed Impervious Area** (so 1 69300 Impervious Area** total 60.0% Impervious** Surface Area Drainage Area 1 Drainage Area Draina e Area Draina ge Area _ On -site Buildings/Lots (so 7,344 On -site Streets (so 0 On -site Parking (so 21,664 On -site Sidewalks (so 557 Other on -site (so 0 Future (so 39,735 Off -site (SO0 AUU I SUN Existing BUA*** (so 0 Total (so: 69,300 Stream Class and Index Number can be determined at: lnttp://portal.ncdeir.or hneb/zorl(ps/esu/classifications Impervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas, sidezoalks, gravel areas, etc. i .: Form SN 11 101 Version 06Aug2012 _.. Paee,3. of 6 field topographic and existing conditions survey. Projects in Union County: Contact DWQ Central Office staff to check if the project is located within a Threatened d Endangered Species watershed that may be subject to more stringent stormwater requirements as per I5A NCAC 02B .0600. V. SUPPLEMENT AND O&M FORMS The applicable state stormwater management permit supplement and operation and maintenance (O&M) forms must be submitted for each BMP specified for this project. The latest versions of the forms can be downloaded from http://portal.ncdenr.org/web/wq/wslsu/bmp-mantial. VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ). A complete package includes all of the items listed below. A detailed application instruction sheet and BMP checklists are available from http://portal.ncdenr.org/web/wqZwsZsu/stateswZforms_docs. The complete application package should be submitted to the appropriate DWQ Office. (The appropriate office may be found by locating project on the interactive online map at htt portal ncdenr.org/web/wq/ws su ma s.) Please indicate that the following required information have been provided by initialing in the space provided for each item. All original documents MUST be signed and initialed in blue ink. Download the latest versions for each submitted application package from http_/f portal ncdenr org/web/wq/ws/su/statesw/forms_docs. Initials 1. Original and one copy of the Stormwater Management Permit Application Form. 6A 2. Original and one copy of the signed and notarized Deed Restrictions & Protective Covenants Form. (if required as per Part VII below) 3. Original of the applicable Supplement Form(s) (sealed signed and dated) and O&M_ agreement(s) for each BMP. n 4. Permit application processing fee of $505 payable to NCDENR. (For an Express review, refer to http://www.envhelp.org/pages/onestopexpress.html for information on the Express program and the associated fees. Contact the appropriate regional office Express Permit Coordinator for additional information and to schedule the required application meeting.) n . - � 5. A detailed narrative (one to two pages) describing the stormwater treatment/managementfor �— the project. This is required in addition to the brief summary provided in the Project Information, item 1. 6. A USGS map identifying the site location. If the receiving stream is reported as class SA or the cj%� receiving stream drains to class SA waters within'h mile of the site boundary, include the'h mile radius on the map. 7. Sealed, signed and dated calculations (one copy). CALA�+'-'�` 8. Two sets of plans folded to 8.5" x 14" (sealed, signed, & dated), including: ck a. Development/Project name. b. Engineer and firm. c. Location map with named streets and NCSR numbers. d. Legend. e. North arrow. I. Scale. g. Revision number and dates. h. Identify all surface waters on the plans by delineating the normal pool elevation of impounded structures, the banks of streams and rivers, the MHW or NHW line of tidal waters, and any coastal wetlands landward of the MHW or NHW lines. • Delineate the vegetated buffer landward from the normal pool elevation of impounded structures, the banks of streams or rivers, and the MHW (or NHW) of tidal waters. i. Dimensioned property/project boundary with bearings & distances. j. Site Layout with all BUA identified and dimensioned. k. Existing contours, proposed contours, spot elevations, finished floor elevations. 1. Details of roads, drainage features, collection systems, and stormwater control measures. m. Wetlands delineated, or a note on the plans that none exist. (Must be delineated by a qualified person. Provide documentation of qualifications and identify the person who made the determination on the plans. n. Existing drainage (including off -site), drainage easements, pipe sizes, runof -ca o o. Drainage areas delineated (included in the main set of plans, not as a separ ig �r pG p. Vegetated buffers (where required). t AUG 01 2014 BY: Form SWU-101 Version 06Aug2012 Page 4 of 6 9. Copy of any applicable soils report with the associated SHWT elevations (Please identify C-L�- elevations in addition to depths) as well as a map of the boring locations with the existing elevations and boring logs. Include an 8.5"xll" copy of the NRCS County Soils map with the project area clearly delineated. For projects with infiltration BMPs, the report should also include the soil type, expected infiltration rate, and the method of determining the infiltration rate. (Infiltration Devices submitted to WiRO: Schedule a site visit far DWQ to verify the SHWT prior to submittal, (910) 796-7378.) A copy of the most current property deed. Deed book: 3526 Page No: 111 For corporations and limited liability corporations (LLC): Provide documentation from the NC _ Secretary of State or other official documentation, which supports the titles and positions held by the persons listed in Contact Information, item la, 2a, and/or 3a per 15A NCAC 2H1003(e). The corporation or LLC must be listed as an active corporation in good standing with the NC Secretary of State, otherwise the application will be returned. http://www.secretary.state.nc.us/Corporations/CSearch.aspx VII. DEED RESTRICTIONS AND PROTECTIVE COVENANTS For all subdivisions, outparcels, and future development, the appropriate property restrictions and protective covenants are required to be recorded prior to the sale of any lot. If lot sizes vary significantly or the proposed BUA allocations vary, a table listing each lot number, lot size, and the allowable built -upon area must be provided as an attachment to the completed and notarized deed restriction form. The appropriate deed restrictions and protective covenants forms can be downloaded from i±tTportal ncdenr org/webL,A,q ws/su/statesw/forms does. Download the latest versions for each submittal. In the instances where the applicant is different than the property owner, it is the responsibility of the property owner to sign the deed restrictions and protective covenants form while the applicant is responsible for ensuring that the deed restrictions are recorded. By the notarized signature(s) below, the permit holder(s) certify that the recorded property restrictions and protective covenants for this project, if required, shall include all the items required in the permit and listed on the forms available on the website, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the NC DWQ, and that they will be recorded prior to the sale of any lot. VIII. CONSULTANT INFORMATION AND AUTHORIZATION Applicant: Complete this section if you wish to designate authority to another individual and/or firm (such as a consulting engineer and/or firm) so that they may provide information on your behalf for this project (such as addressing requests for additional information). Consulting Engineer:Rob Balland Consulting Firm: Paramounte Engineering, Inc Mailing Address:5911 Oleander Drive Suite 201 City:Wilmington State:N.C. Zip:28403 Phone: (910 ) 791-6707 Email:rballand@paramounte-eng.com Fax: (910 ) 791-6760 IX. PROPERTY OWNER AUTHORIZATION (if Contact Information, item 2 has been filled out, complete this section) I, (print or type name of person listed in Contact Information, item 2a) certify that I own the property identified in this permit application, and thus give permission to (print or type name of person listed in Contact Information, item la) with (print or type name of organization listed in Contact Information, item 1a) to develop the project as currently proposed. A copy of the lease agreement or pending property sales contract has been provided with the submittal, which indicates the party responsible for the operation and maintenance of the stormwater system. ECEO®YE AUG 01 2014 Form SWU-101 Version 06Aug2012 Page 5 of As the legal property owner I acknowledge, understand, and agree by my signature below, that if my designated agent (entity listed in Contact Information, item 1) dissolves their company and/or cancels or defaults on their lease agreement, or pending sale, responsibility for compliance with the DWQ Stormwater permit reverts back to me, the property owner. As the property owner, it is my responsibility to notify DWQ immediately and submit a completed Name/Ownership Change Form within 30 days; otherwise I will be operating a stormwater treatment facility without a valid permit. I understand that the operation of a stormwater treatment facility without a valid permit is a violation of NC General Statue 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $25,000 per day, pursuant to NCGS 143-215.6. Signature: a Notary Public for the State of County of ____________ ______ ,do hereby certify that_ -------------------------------------- personally appeared before me this _ day of ----_ ----, _ ---__, and acknowledge the due execution of the application for a stormwater permit. Witness my hand and official seal, SEAL My commission X. APPLICANT'S CERTIFICATION 1, (print or type name of person listed in Contact Information, item 1 a) Jason Swain, Authorized Agent certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective co 11 be recorded, and that the proposed project complies with the requirements of the applicable sto es under 15A NCAC 2H .1000 and any other applicable state stormwater requirements. 7 Signature: Date: n(o /I � 12.0 l 1, L)kMf\a_I`�_ v � D n no �---------- a Notary Public for the State of _�o 41h Car-o( i nq-, County of o u)_ i4tA00e _, do hereby certify that J O 5 o vv O Swa_(\ __ personally appeared -------- -- before me this I ay of _J u n1+� _-_______- -20 11, and ac/nowledge the due execution of the application for a stormwater permit. Witness my hand and official seal, __ �/� (�y(�i`�*=-`a✓L--------------- ,�,OTAR), .A• pUBl1G SEAL My commission expires ll l?, Z/ Z D IY EC EE AUG 0 12014 BY: Form SWU-101 Version 06Aug2012 Page 6 of 6 MEMORY TRANSMISSION REPORT FILE NO. 434 DATE 08.06 12:41 TO n 97916760 DOCUMENT PAGES 8 START TIME 08.06 12:41 END TIME 08.06 12:44 PAGES SENT 8 STATUS OK TIME FAX NO.1 NAME `SUCCESSFUL TX NOTICE- :08-06-2014 12:44 9txta of Nortb Cxrollnx Depwrtmen[ o[8nv[rov mev[ wnJ Nw[urv[ Ruov rear Wnm[nQ[nv Rvglonsl O(Ow pw/McG}ory� Gwvnrvxr P'AX COVER F[[lCC'T Jahv SSh.•n�1w II! cn<..,tn.y n4m: ��G � �� Na. Pagan (exU. covarj: J [o[ 1004 � za c..4m.� u.we ume...�...., wnna.,�nn, Nc zxaos - <v. o> o9c-tea[ s . nn gy..m oppom,n�y wm..xen.e wen.,., en,pmya State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Pat McCrory, Governor FAX COVER SHEET John ESkvarla III, Secretary Date: To: Co: Fax: %611 // Re: t. �Ei�/�S/ f9V '%t /DBZ� i No. Pages (excl. cover): From: Jo Casmer Phone: (910) 796-7336 Fax: (910)350-2004 127 Cardinal Drive Extension, Wilmington, NC 28405 • (910) 796-7215 • An Equal Opportunity Affirmative Action Employer MEMORY TRANSMISSION REPORT r FILE NO. 435 DATE 08.06 12:42 TO : a 92562171 DOCUMENT PAGES 8 START TIME 08.06 12:44 END TIME 08.06 12:46 PAGES SENT 8 STATUS OK TIME FAX NO.1 NAME `SUCCESSFUL TX NOTICE"" 08-06-2014 12:46 9mb of North Carollov D.partment of 6nvlroomant and Natural Be.ourcu ' wnmta¢ma Reglana omee Par McCivry, a:ovarvor FAX COVER HfiEET John SSh�wr/v lfl, Secretary No. l'o11vs (cxcl. cover): _, From. Phone. totm oae_-�aa6 Fax: toltn3 __004 _ ]2'l Ov[dia.al L lvn ar�m.olnn. Wn�n/ngmn. NC 2890� � C91e) "196-TLtS � M Bqu nl OPP��t�nay Atn�n�etfvn Aotlnn Crt�Ployer Pat McCrory, Governor State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office FAX COVER SHEET John E Skvarla III, Secretary Date: To: ✓ /OSO/J SGrJ�j / /7 Co; Fax: 2 71 Re: S �iE/ /��J>D XS No. Pages (excl. cover):_ From: Jo Casmer Phone: (910) 796-7336 Fax: (910)350-2004 127 Cardinal Drive Extension, Wilmington, NC 28405 • (910) 796-7215 • An Equal Opportunity Affirmative Action Employer - _. _..... _ .... - _...... PARAMOUNT E��krss E N G I MEE FRI MC,—, I N C. p� 5 9 1 1 O 1, E A N D E R D R I V E S U I T E 2 0 1 W I L NI I N G T O N, N C 2 8 4 0 3 910-791-6707(0) 9 1 0 - 7 9 1 - 6 7 6 0 (P) 911 L E T T E R O F T R A N S M I T T A L To: ; NCDENR Date 7/1/14 127 Cardinal Drive Ext. Wilmington, NC 28403 Re: O'Reilly Auto Parts — Shallotte Attn: Chris Baker Pro'ectNo. I 13287.PE e ate sendin ® Originals ® Prints ❑ Shop Drinvings ® Calculations ❑ Correspondence ® Plans ❑ Specifications ® Other as listed below he followin `items: Quantity Date Dwg. No. i . Description- 2 24"x 36" Design Documents 2 6/11/14 Form SWU-101 (1 original, l copy) 1 Form SW-401 (Wet Detention Basin Supplement)' 1 6/11/14 Operation & Minnie wince Agreement 1 6/11/14 Check #1167 for application fee ($4,000) 1 6/16/14 Stormwater Narrative & Calculations Issue Status ® For Approval ❑ As Requested ❑ Construction ❑ Bid ❑ For Your Use ❑ For Review and Comment ❑ Approved as Noted ❑ See Remarks etion Taken: ❑ No Exceptions Taken ❑ Make Corrections Noted ❑ Amend & Resubmit O'REILLY AUTO PARTS 4607 Main Street Town of Shallotte BRUNSWICK COUNTY, NC STORMWATER - EROSION CONTROL NARRATIVE Prepared For: SHALLOTTE DEVELOPERS, LLC 1121-P Military Cutoff Road Wilmington, NC 28405 Prepared by: pARAMOUNTE C N G I N C C R I N G. I N C. 5911 Oleander Drive, Suite 201 Wilmington, NC 28403 NC License k: C-2846 Project #13287.PE June 2014 O'REILLY AUTO PARTS 4607 Main Street Town of Shallotte BRUNSWICK COUNTY, NORTH CAROLINA Project #13287.PE Table of Contents Design Narrative Proposed Improvements Maintenance Erosion and Sedimentation Control Specification Pender County Soils Map USGS Map Stream Classification Secretary of State Documents Deed Calculations Page i DESIGN NARRATIVE Shallotte Developers, LLC proposes to construct a retail building at the corner of Main Street (US Highway 17 Business) and Hinson Street within the Town of Shallotte in Brunswick County, NC. As a result, please find this design narrative, plans, and supporting calculations sufficient for the stormwater quality and quantity control according to NCDENR regulations. The address of the property is 4607 Main Street, Shallotte, NC with a latitude and longitude of 33°58'40"N, 78°22'42"W (Parcel ID#108816836551; Deed Book 3526 Page 111). There is currently some existingimpervious on the property with the majority of the site being good open space. Soils consist of Baymeade & Marvyn (BDC), Longshoal Muck (LA), and Norfolk loamy fine sand (NoB) according to the provided soils map from NRCS and have a HSG classification of either A or A/D. According to the attached USGS map, the project drains to Woodward Branch, C;Sw,HQW, which is within the Lumber River Basin. PROPOSED IMPROVEMENTS-STORMWATER/EROSION CONTROL The applicant is proposing to build a retail building along with associated parking, utility services, and a stormwater management system. It is proposed that all runoff resulting from impervious surfaces will be collected by a storm drainage collection system and then be conveyed to a wet detention pond where stormwater quality requirements will.be met. The pond has been designed to meet NCDENR requirements which include a forebay and a drawdown orifice at permanent pool. Stormwater from greater storm events will be allowed to exit the wet detention pond by means of a riser barrel outlet structure and a secondary spillway during emergency situations. The seasonal high water table for the project was determined by RFTS Soil Engineering and Testing Services and was determined to be approximately 29 inches below the existing grade in the vicinity of the proposed stormwater wet detention basin. The find in the report referring to seasonal high water are attached to this report. In regards to erosion control, it is proposed to install inlet protection at the storm the drain inlets to prevent sediment from entering the system, as well as silt fence and temporary construction entrances on Main and Hinson Streets, temporary sediment basin with skimmer and outlet protection. Please see Sheet C-1.0 for all Erosion Control and Sequence of Construction notes. The sedimentation and erosion control design will commence as depicted in the construction sequence. Please find all reference material and stormwater / erosion control calculations in the following pages of this report. Note that some calculations have also been located on the plans for easy reference during construction. MAINTENANCE Contractors shall be responsible for periodic inspection and maintenance of all indicated erosion control devices in accordance with the plans and specifications. In addition, inspection Page 1 and any necessary maintenance will be required immediately following any significant storm event. Sediment will need to be removed from behind silt fencing as described on the Erosion Control Plan. Vegetative cover will be fertilized and reapplied as necessary to promote a vigorous stand. Page 2 EROSION AND SEDIMENTATION CONTROL SPECIFICATION PART1-GENERAL 1.1 RELATED DOCUMENT A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. 1.2 WORK INCLUDED A. Contractor shall take every reasonable precaution throughout construction to pr•_vent the erosion of soil and the sedimentation of streams, lakes, reservoirs, other water impoundments, ground surfaces, or other property as required by State and Local regulations. B. Contractor shall, upon suspension or completion of land -disturbing activities, provide protection covering for disturbed areas. Permanent vegetation shall be established at the earliest practicable time. Temporary and permanent erosion control measures shall be coordinated to assure economical, effective, and continuous erosion and sediment control throughout the construction and post construction period. 1.3 RELATED SECTIONS A. Related Sections —The following Sections contain requirements that relate to this Section: 1. 01011 — Existing Underground Utilities 2. 01015 — Special Conditions for this Contract 3. 01070 — Shop Drawings, Project Data & Samples 4. 02200 — Earthwork, Excavation Trenching, and Backfilling 5. 02230 — Site Clearing 6. 02240 — Dewatering 7. 02485 — Seeding General Areas 1.4 REGULATORY REQUIREMENTS A. Contractor shall be responsible for prevention of damage to properties outside the construction limits from siltation due to construction of the project. The Contractor will assume all responsibilities to the affected property owners for correction of damages that may occur. Erosion control measures shall be performed by the Contractor, conforming to the requirements of, and in accordance with plans approved by applicable state and local agencies and as per the erosion control portion of the construction drawings and these specifications. The Contractor shall not illow mud and debris to accumulate in the streets. Should the Contractor pump water from trenches during construction, appropriate siltation preventative measures shall be taken prior to discharge of pumped water into any storm drain or stream. Page t PART 2-PRODUCTS 2.1 Open mesh biodegradable mulching cloth. 2.2 Fertilizer shall be 10-10-10 grade or equivalent. 2.3 Lime shall be dolomitic agricultural ground 1 limestone containing not less than 10 percent magnesium oxide. 2.4 Phosphate shall be 20 percent super phosphate or equivalent. 2.5 Provide grass seed mixture as shown on the plans. 2.6 Silt fence shall consist of non -biodegradable filter fabric (Trevira, Mirafi, etc.) wired to galvanized wire mesh fencing and supported by wood or metal posts. 2.7 NCDOT Class B stone for erosion control. PART 3-EXECUTION 3.1 CLEARING A. Clearing and grubbing shall be scheduled and performed in such a manner that subsequent grading operation and erosion control practices can follow immediately thereafter. Excavation, borrow, and embankment operations will be conducted such that continuous operation. All construction areas not otherwise protected shall be planted with permanent vegetative cover within 7 working days after completion of active construction. All slopes shall be planted within 14 calendar days after completion of such activity. 3.2 STABILIZING A. The angle for graded slopes and fills shall be no greater than the angle that can be retained by vegetative cover or other adequate erosion control devices or structures. All disturbed areas not to be paved and left exposed will, within 14 calendar days of completion of any phase of grading, be planted or otherwise provided with either temporary or permanent ground cover, devices, or structures sufficient to restrain erosion. All slopes steeper than 3:1 shall be planted or otherwise provided with either temporary or permanent ground cover, devices, or structures sufficient to restrain erosion within 14 calendar days. 3.3 REGULATORY REQUIREMENTS A. Whenever land disturbing activity is undertaken on a tract, a ground cover sufficient to restrain erosion must be planted or otherwise provided within 7 calendar days on that portion of the tract upon which further active construction is to being undertaken. B. If any earthwork is to be suspended for any reason whatsoever for longer than 7 calendar days, the areas involved shall be seeded with vegetative cover or otherwise protected against excessive erosion during the suspension period. Suspension of work in any area of operation does not relieve the Contractor of the responsibility for the control of.erosion in that area. Page 2 PART 4 - CONSTRUCTION PHASE 4.1 PRACTICES A. Avoid dumping soil or sediment into any streambed or watercourse. Backfill for stream crossings shall be placed dry and compacted to minimize siltation of the watercourse, where applicable. B. Maintain an undisturbed vegetative buffer where possible between a natural watercourse and trenching and grading operations. C. Avoid equipment crossings of streams, creeks, and ditches where practicable. PART 5 - SEDIMENT CONTROL FEATURES 5.1 GENERAL A. All devices (silt fences, retention areas, etc.), for, sediment control shall be constructed at the locations indicated prior to beginning excavation on the site. All devices shall be properly maintained in place until a structure or paving makes the device unnecessary or until directed to permanently remove the device. 5.2 DESIGN APPLICATIONS A. Mulch shall be used for temporary stabilization of areas subject to excessive erosion, and for protection of seed beds after planting where required. 1. Jute, mesh, etc. should be installed as per manufacturer's instructions. B. Silt fences shall be used at the base of slopes and in drainage swales to restrict movement of sediment from the site. Straw bales may be required for reinforcement. C. Riprap shall be used at the proposed outfall pipes as indicated on plans. D. Establish vegetative cover on all unpaved areas disturbed by the work. 1. Preparation of Seedbed. Areas to be seeded shall be scarified a depth of 6 inches until a firm, well -pulverized, uniform seedbed is prepared. Lime, phosphorous, and fertilizer shall be applied during the scarification process in accordance with the following rates. a. Lime — 2 ton per acre b. Nitrogen —100 pounds per acre C. P2O5 — 200 pounds per acre 2. Seeding. Disturbed areas along roads and ditches shall be permanently seeded with 10-20 pounds per acre of centipede during the period from March through September. Seeding performed during the period from April to August shall be temporarily seeded with 40 pounds per acre of German Millet. The permanent vegetative cover will be over seeded at the earliest possible time as specified above. 3. Mulch all areas immediately after seeding. Mulch shall be applied and anchored as specified hereinbefore. Page 3 5.3 MAINTENANCE A. The Contractor shall be responsible for maintaining all temporary and permanent erosion control measures in functioning order. Temporary structures shall be maintained until such time as vegetation is firmly established and grassed areas shall be maintained until completion of the project. Areas which fail to show a suitable stand of grass or which are damaged by erosion shall be immediately repaired. 5.4 REMOVAL OF SEDIMENT CONTROL DEVICES A. Near completion of the project, when directed by the Owner's agent, the Contractor shall dismantle and remove the temporary devices used for sediment control during construction. All erosion control devices in seeded areas shall be left in place until the grass is established. Seed areas around devices and mulch after removing or filling temporary control devices. END OF SECTION 02410 Page 4 Swain & Associates, Inc. 1121-P Military Cutoff Road Wilmington, North Carolina 28406 Attention: Mr. Gary Lattie Reference: Report of Subsurface Exploration Proposed O'Reilly's Auto Parts Store and Outparcel Shallotte, North Carolina RFTS Job No. 912-13 Dear Mr. Lattie: Pursuant to the scope of our Proposal No. 1019-13, dated November 1, 2013, RFTS has recently completed an exploration of subsurface conditions within the area of a proposed O'Reilly's Auto Parts Store and an adjacent outparcel located in Shallotte, North Carolina. This letter serves as the report of our work. We present herein our understanding of the relevant project information, a description of our field activities, our findings, and recommendations relating to foundation support of the subject structure. PROJECT INFORMATION Our understanding of the relevant project information is based on our conversations with you. We have been provided with a conceptual site plan superimposed on an aerial photograph of the property which shows the configuration of the building and appurtenant pavement areas. The site of the proposed O'Reilly's Auto Parts Store is located in the southwest corner of the intersection of Main Street (U. S. Highway 17) and Hinson Street in Shallotte, North Carolina as shown in the Boring Location Plan attached hereto as Figure 1. As we understand, proposed construction consists of a single -story metal -frame building with masonry walls. We have not been provided with loading information for the structure; however, we have assumed for the purposes of the analysis herein that wall loads on continuous footings will not exceed 6 kips per lineal foot and that individual column loads on isolated footings will not exceed 50 kips. If actual design loads should turn out to be more substantial, we should be contacted so that we may revise or expand our recommendations. For the purposes of providing recommendations for pavement section design, we have assumed that the bituminous pavement adjacent to the building will accommodate loads RFTS, PLI ­C Cornmittetl to Responsive Service Phone: 910-470-7450 1305 3A Carolina Beach Ave N Carolina Beach, North Carolina 28428 Wtvit'.rftsplic.com Email: aaviawinstead(echarter.net Swain & Associates, Inc. November 12, 20L3 RI TS Job No. 912-13 Page Two and traffic typical of this type of retail facility; i.e., light vehicle parking and drives which will experience occasional heavy -axle -load delivery traffic. We have not been provided with information as to the exact location or type of construction to be conducted within the outparcel area east of the store site. For our purposes herein; we have assumed that the type of construction will be similar to that of the auto parts store. DESCRIPTION OF EXPLORATION ACTIVITIES Soil Borings In order to obtain subsurface data to form the basis for our recommendations, six soil borings wcrc advanced at the approximate locations shown in Figure I to a depth of 20 feet below site grade using a trailer -mounted rotary drilling rig. Borings B-1, B-2, and B- were advanced within the area of the proposed auto parts store, and Borings B-4, B-5, and B-6 were advanced within the outparcel area. Soil samples were recovered and Standard Penetration (SPT) Testing was conducted at routine depth intervals in general accordance with the procedures set forth in ASTM D1586. The locations of the borings were determined in the field by pacing and estimating distances from known site features and should be considered only as accurate as the limitations implied by these methods. At the completion of drilling, standing water levels in the boreholes were determined and recorded. The use of drilling fluid in the wash -boring techniques used for our exploration can result in standing water levels in the boreholes at variance with and less accurate than watertable levels obtained by other methods, such as the installation and reading of peizometers. The soil samples obtained in the field were delivered by the drillers to the undersigned authors of this report who classified them in general accordance with the Unified Soil Classification System (USCS) as set forth in ASTM D2487 using the visual/manual procedures set forth in ASTM 2488. The boring logs included with this report were then prepared based on those classifications and the drillers' field logs. Hand Auger Borings In addition to the soil borings, we advanced 4 hand auger borings (HA-1 through HA-4) to depths ranging from 4 feet to 5 feet below grade at the approximate locations shown in Figure 1. Hand auger boring HA-1 was advanced to a depth of 4 feet within an area proposed for a stotmwater infiltration structure. The encountered soils were visually/manually classified Swain & Associates, inc. November 12, 2011 RFTS Job No. 912-13 Page Three and logged by depth, and their coloration was compared to a Munscll Soil Color Chart to determine their hue, value, and chroma. This information was used to estimate the seasonal high water table level. The depth to standing water in the borehole was also measured at the completion of augering. Hand auger borings HA-2, HA-3, and HA-4 were advanced to a depth of 5 feet within the proposed pavement area at the approximate locations shown in Figure 1. The encountered soils were visual iv(manualIy classified by depth, and dynamic cone penetrometer (DCP) testing was conducted at routine depth intervals to determine the in -.situ relative density of the soils. The depth to standing water in the borcholes was recorded at the completion of augering. FINDINGS The findings of our subsurface exploration are based on the conditions discovered in our soil borings and hand auger borings as detailed in the boring logs and on our observations while on site. We summarize them as follows: y Site Description The site of the proposed auto parts store and adjacent pavement areas is a relatively flat sparsely grassed field with no trees or above -ground structures. It ranges in elevation from about +10 feet MSL to +12 feet MSL. The outparcel area is a relatively flat parking and drive area with elevations ranging from +6 feet MSL to +7 feet MSL. Ground elevations in the vicinity of the site slope downward from west to east, with elevations being higher to the west and lower to the east of the property. A commercial building occupies the area between the site of the proposed auto parts store and the outparcel explored for this study. We have no information about the development history of either portion of the site and can offer no opinion as to the likely presence of buried utilities or foundations on the property. Subsurface Conditions Subsurface conditions encountered in our borings consisted in general of the following: Auto Parts Store Building Area. Our borings in this area all encountered interbedded sandy clay and clayey sand (USCS Soil Groups `CL' and `SC') in the upper 5 to 6 feet below site grade, these soils occurring in in-sim conditions ranging from soft to frrn/medium dense. These clayey soils were underlain in all three borings by relatively clean medium dense sands (`SP', `SP-SC') extending to depths ranging from 11 to 15 feet. In borings B-1 and B-2, these clean sands were underlain by very soft clay (`CH'). The very soft clay layer extended from 13 to 17 feet below grade in B-1 and from 1 1 to Swain & Associates, Inc. November 12, 2013 RFTS Job No. 912-13 Page Four 18 feet below grade in B All three borines terminated in medium dense to very dense weathered rock at depths ranging from 15 to 17 feet. Auto Parts Store Parking Area. Beneath a surficial layer of topsoil and crushed aggregate base ranging in thickness from 8 to 12 inches, our hand auger borings advanced within the proposed store parking area encountered clayey sands and sandy clays ('SC' and 'CU). These soils generally occurred in a medium dense/firm insitu condition. The logs of these hand auger borings (I A-2, HA-3, HA-4) are shown in Table 1 (attached hereto). Outparcel Area. The borings advanced within the area of the outparcel all encountered and terminated in medium dense to very dense weathered rock, with the depth at which the rock was encountered ranging from 10 to 12 feet below grade. Above this rock laver, the borings encountered a variety of interbedded layers of sandy clay, clayey sand, and clean sand ('Cl-', 'SC', and 'SP'), with most of these layers occurring in a very loose to loose or very soft to soft in -situ state. Groundwater Standing water levels recorded in the boreholes at the completion of drilling and in the hand auger borings ranged from 3 to 5 feet below site grade. As noted above, these observed levels can be influenced by the presence of drilling fluid in wash borings. Groundwater levels may vary with seasonal fluctuations in precipitation and will be higher after periods of prolonged or heavy rainfall. Seasonal High Watertable Estimate Soils encountered in hand auger boring HA -I consisted of interbedded clean tine sands (USCS Soil Group 'SP') in the upper 34 inches below the existing ground surface. Below that depth and continuing to a depth of 43 inches fine sand with silt (USCS Soil Group 'SM') was encountered. And from 43 inches to the boring termination depth of 50 inches, sand with clay (USCS Soil Group 'SC') was encountered. No distinct zones of soil cementation were encountered in the profile. Based on our experience with similar soils and comparisons of the soil coloration to the Munsell Chart, it is our opinion that seasonal high water table level occurs approximately 29 inches below the existing the ground surface..A measurement made 1 hour after augering indicate depths to standing water in the borehole of 45 inches below the existing ground surface. Our field data is detailed in Table 14 below. Swain & Associates. Inc. RFTS Job No. 912-13 Table 2 Munsell Soil Classifications Proposed O'Reilly's Auto Parts Shallotte, North Carolina RUTS Job No. 912-13 November 12, 2013 Page Five Loc Soil Description Hue Value Chroma Depth Comments (in.) I Topsoil/ABC Stone - 0-11 Pale Brown fine SAND 1 OYR 6 3 11-16 Very Dark Grayish Brown fine I OYR 3 2 16-22 SAND Dark Yellowish Brown fine IOYR 4 4 22-26 SAND Very Dark Grayish Brown fine 1 OYR 3 2 26-29 SAND Gray fine to medium SAND 2.5Y 6 1 29-34 SIIWT Very Dark Brown fine SAND l OYR 2 2 34-43 with Silt Yellowish Brown fine SAND 10YR 5 4 43-50 H>O@45" with Clav RECOiMMENDATIONS Our analysis and recommendations herein have been developed in accordance with standards of practice generally accepted within geotechnical engineering practice in this region and at the time of the preparation of this report. No other warranty, express or implied, is made. Inasmuch as subsurface conditions can and do vary significantly between the locations of borings, it is entirely possible that conditions not contemplated within our analysis and recommendations may be discovered during the course of construction. In this event, wewill be pleased to revisit our recommendations and expand or modify them. Our recommendations are predicated upon our understanding of the proposed construction as set forth under the heading Project Information in this report. Any features of the actual design or construction of the project which may be at variance with the assumptions set forth therein should be brought to our attention so that we may revise or expand our recommendations as appropriate. Site Preparation Site preparation within the areas of buildings and pavements should be initiated by stripping surticial organics and topsoil from grassed areas and demolishing any existing a Legend ® APPROXIMATE SOIL BORING LOCATION Ea APPROXIMATE HAND AUGER LOCATION SOIL BORING AND HAND AUGER LAYOUTS FIGURE 1 PROPOSED O'REILLY'S AUTO PARTS DRAWING NOT TO SCALE RFTS, PLLC RFIS 4607 MAIN STREET AND HINSON DRIVE DATE: 11/12/13 Carolina Carolina Beach Ave N CaroBeach, North Carolina 28428 Soils Engineering and SHALLOTTE, NORTH CAROLINA SKETCH: DLW orrce:910-470-7450 - JOB NO, 912-13 IREVIEW: ._ SDK _ NC DENR - DIVISON OF WATER QUALITY .0310 LUMBER RIVER BASIN Class Name of Stream Description Class Date Index No. 2B .0300 Pamlico Creek (Pompeys From Brunswick County SR SC;HQW 08/01/90 15-25-1-15-(2) Creek) 1115 to Lockwoods Folly River Lockwoods Folly River From Brunswick County, SR SA;HQW:G 12/13/79 15-25-1-(16) 1200 to Intra-coastal Waterway Stanbury Creek From source to Lockwoods C;Sw,HQW 08/01/90 15-25-1-17 Folly River Mill Creek From source to Brunswick C;Sw,HQW 08/01/90 15-25-1-18-(1) County SR 1112 Mill Creek From Brunswick County SR SA;HQW 12/01/63 15-25-1-18-(2) 1112 to Lockwoods Folly River Mullet Creek From source to Lockwoods SA;HQW:@ 12/01/63 15-25-1-19 Folly River Lockwoods Creek From source to Lockwoods SA;HQW:® 12/01/63 15-25-1-20 Folly River Spring Creek From source to Lockwoods SA;HQW:® 12/01/63 15-25-1-21 Folly River Shallotte River From source to N.C. Hwy. 130 C;Sw,HQW 08/01/90 15-25-2-(1) Saw Pit Swamp From source to Shallotte C;Sw 12/01/63 15-25-2-2 River Cool Run From source to Shallotte C;Sw 12/01/63 15-25-2-3 River McMilly Swamp From source to Shallotte C;Sw 12/01/63 15-25-2-4 River Lookout Branch From source to Shallotte C;Sw,HQW 08/01/90 15-25-2-4.5 River Shallotte River From N.C. Hwy. 130 to U.S. SC 12/01/63 15-25-2-(5) Hwy. 17 Meetinghouse Branch From source to Shallotte C;Sw 03/01/77 15-25-2-6 River Mulberry Branch From source to Shallotte C;Sw 12/01/63 15-25-2-7 River Williams Branch From source to Mulberry C;Sw 12/01/63 15-25-2-7-1 Branch Shallotte River From U.S. Hwy. 17 to mouth SC;HQW 08/01/90 15-25-2-(7.5) of the Mill Pond Woodward Branch (Charles From source to Shallotte C;Sw,HQW 08/01/90 15-25-2-8 Branch) River Sharron Creek (Grissett From source to Williams C;Sw,HQW 08/01/90 15-25-2-9-(1) Swamp) Branch Sharron Creek (Grissett From Williams Branch to SC;HQW 08/01/90 15-25-2-9-(2) Swamp) Shallotte River Williams Branch From source to Sharron C;Sw,HQW 08/01/90 15-25-2-9-3 Creek (Grissett Swamp) Page 20 of 23 2013-12-09 10:49:42 North Carolina Secretary of State . http://www.secretary.state.ilc.tis/corporations/Coi-p.aspx?Pitemld=10417132 AI`/`CL-f I -in Ranic}Fr North Carolina Elaine F. Marshall DEPART[MEN T OFTHE Secretary SECRETARY OF STATE PO Box 29622 Raleigh, INC 2762"622 (919)007-2000 Date: 5/27/2014 Click here to: View Document Filings I File an Annual Report �` I Print a Pre -populated Annual Report Fillable PDF Form I Amend A Previous Annual Report Corporation Names Name Name Type NC SHALLOTTE DEVELOPERS, LLC LEGAL Limited Liability Company Information SOSID: 1355272 Status: Current -Active Effective Date: 1/7/2014 Citizenship: DOMESTIC Duration: PERPETUAL Annual Report Status: CURRENT Registered Agent Agent Name: SWAIN, JASON D. Office Address: 1121 P MILITARY CUTOFF ROAD WILMINGTON NC 28405 Mailing Address: 1121 P MILITARY CUTOFF ROAD WILMINGTON NC 28405 Principal Office Office Address: 1121 P MILITARY CUTOFF ROAD WILMINGTON NC 28405 Mailing Address: 1121 P MILITARY CUTOFF ROAD WILMINGTON NC 28405 Officers/Company Officials This website is provided to the public as a part of the Secretary of State Knowledge Base (SOSKB) system. Version: 3152 I of 1 5/27/2014 4:I6 NM This certifies mat mere are no delinquent as -� f b " 1 4: ' IIIIIII119N11'IIIIIIillllllllllllllll 2Srunsucak County, NC Register a35z6 aaiii re%nr. sea9t PROP of Deeds page 1 or 4 valorem taxes, fees, assessments or other -�I I I \• t I I �(l: J liens which the Brunswick County lax _ .1:� �'S(�'j�'i: s � - G- �' Collector is charged with Ileding, that area Parcel Number, charged lien Collectorwith�8 an • �• RP.C. �, as notated by the Brunswick County I total f:-sir f�T�Ir, r7 Ck $ C!;'UrjQCash 5 Assessor's Office. This is not a certification Refunt C,-,h f. Finance that the parcel number matches the deed __._-. ❑Pomorso dx� to wDirdon descdptbn. MAY 1 4 2014 ofo-' I _ ,.A �PtlIXMt+ - yar,5inal �t Date (Asst) Tax Col. / Del. Tex Spec. ,, r ( `:'^imh^ . , . ? nr --,'d, NORTH CAROLINA SPECIAL WARRANTY DEED Excise Stamps: $0.00 The property herein conveyed is not Gran �toi?s primary restdeneSctNG(Ii 105-317.2) rr jjLL111rt � f I After recording:Mail to Blanco Tackaticryf,P.O'Drawer 25008 Wihsion`-Salem, NC 27114-5008, GEH This instrument was prepared by: Amy C Lannine Brief description for the index: 1.318 Acres, Lot 2, Main Street THIS DEED is made as of May J_4, 20141 by and between: Shallotte Investments, LLC, a North "i 11 Carolina limited liability company, grid Shallotte Developers, LLC, a North Carolina limited liability company c/o Swain & Associates, LLC 1121-P Military Cutoff Road Wilmington, NC 28405 10'est Z" rits, LLC, a North Carolina c/o Swain & Associates, LLC 1121-P Military Cutoff Road Wilmington, NC 28405 The designation Grantor and Granteea$ used and assigns, and shall include singular, plural, said parties, their heirs, successors, or neuter as required by context. WITNESSETH, that for and in consideration of cash in hand paid and other good and valuable consideration, the receipt and sufficiency of which is hereby acknowledged, the Grantor has and by these presents does grant and convey unto the Grantee in fee simple, all of that certain lot or parcel of land situated in Brunswick County;°North Carolina and more rparticularly described on Exhibit A, attached hereto and made a part hereof (the6,'Propertyj); rir.�✓ p i , I TO HAVE AND TO HOLD the a{oar¢�jhtq-Ioi/tort,gazce4:oF',}ansLand all privileges and appurtenances thereto belonging to the Grantee in fee simple.,i,, AND THE GRANTOR covenants with the Grantee that Grantor is seized of the Property in fee simple, has done nothing to impair such title as Grantor received, and that Grantor will warrant and defend the S 545692vI ;IL 5.t - n. " I191�1')IIi�IIII'IIIIIIIIIIIIIIIIIIIIII 83526 P0112 men,=39IRW l���I\1����r�,r BrunsuacK�Coanty, NC Register of Deeds page 2 of / title against the lawful claims of all persons claiming by, Vnder or through Grantor, except for the exceptions hereinafter stated. Title to the Property is subject to the following exceptions: 1. Ad valorem taxes for 2014 and thereafie 2. All easements, rights of ways and btherrestneuons an3"encumbrances of record affecting the Property. Separate Signature Page to Follow 4 4•Gi if ��'� � IJ i erh. t- I i �jl, A 1 DTMt545692vt W Il,tl �r . ,u hJ�Vi ��9/`n�iUGllri t ``a= , fIIIIIIII�IIlI1��11111111111111111111 a35ss P911I .-t. P ten z: as. oea / Drench n. Cteemono PROP ��JrV r a",su eM nt NC Re liter Of Deeds page 3 f 1 if6'r, ram, v, a IN WITNESS WHEREOF, Grantor has caused this instrument to be signed in its name by their duty authorized signatories, as of the day and year first above written. Sh tments, LLC iN�me`71 lr�.>?a n a �,� Title: ty{U rR= Sha topers, LLC By Ti i1 I (r I I STATE OF NORTH CAROLINA COUNTY OF NPJ..V �jafnoUfT- 1 certify that the following person personally appeared before me this day and acknowledged that she/he voluntarily Signed the foregoing document for the purpose stated therein and in the capacity indicated: s4bon O. e�VXI�n as the mongP@rr of Shallotte lnvestments, LLC I Date: N\0-t{ 12 .2014. .,� � �dl����,Ll•t pvL. I. I l `of8 iat'Signature qr jNl tgry Public _. jwnn4�1�'sS�4Nyro✓1 Insert time of Notary, printed or typed O aptAgy t U ZZ12D12 (Official Sear .pe = My Commission Expires: STATE OF NOR4 OL - QF 4ry vER„"1�1�� COUNTY OF A%2LV � ✓Pi �� :I `� CJi'Bit .'1 f1 •'a I certify that the following person personally appeared before me this day and acknowledged that she/he voluntarily signed ,the foregoingg,� document for the purpose stated therein and in the capacity indicated: )4SDrtO. i Qth asthe Marlq,�et of Shallotte Developers, LLC Date: Z .2014 ,. %Of'ipthJ9lggnwedfNotary Public Insert name 'of printed or typed (Official Seal) aTM: 545692,1 °TAgy\i` I/ zz 20/� My Commission Expires: " IIIIIII'IIIIII I+I1II IIIIIIIIIIIIIII III 63526 P0114 DS_,E_39 10: 4:39.000 1 Brenda M. Clenmsnop s PR 11i J\ �� anunsvSHk':cunSy, NC Register e( Deeds page 4 xf EXHIBIT A THE PROPERTY Being the following tracts or parcelsrlocated in the Towm of S41lotte, Lockwood Folly Township, Brunswick County,North Carolina, and'$eing more particularlg dCkribed as follows: , r.n:'ril -ern rig � BEGINNING at an iron pin located1ih, lthe'soulhem nghi+)fwayi:of Main Street (U.S. 17 Business), said iron pin being the northwest comer of the'prbpeRy,{owned, now or formerly, by Flangill Family, LLC (Book 2583, Page 1073); thence from said point and place of beginning and with the western line of Hangill, South 39 deg. 45 min. 56 sec. East 171.10 feet to an iron pin; thence with the southern line of Hangill, North 58 deg. 04 min. 06 sec. East 82.89 feet to a point in the centerline of Charles Branch located in the western line of property owned, now or formerly, by MM Fowler, Inc. (Book 1489, Page 517); thence with the centerline of Charles Branch (which is the LwI estem line of MM Fowler, Inc. and continuing with the western line of propentylowned,-ngr,9rtf �erly'by Evanston Shallotte, LLC (Book 3194, page 735)) to a point which is Soluth122'd�g �� I Irvin' `35 sec. East 188.33 feet from the preceding stated point; thence leaving the centZ�rhri��tlf Char'es Branch Youtli''73 deg. 40 min. 59 sec. West 48.44 s: feet to an iron pin; thence South 81 deg. 18 min. 17`se6!=W stgj59.I3 feet to an iron pm; thence North 39 deg. 26 min. 29 sec. West 260.39 feet to an iron pin located on the southern line of Main Street; thence with the southern line of Main Street North 50 deg. 03 min. 11 sec. East 153.50 feet to the point and place of BEGINNING and containing 1.318 acres more or less as shown on a subdivision map prepared by Paramounte Engineering, Inc. and bearing project number 13287.PE. , B rM.545692,1lh,14 i,, Project Name: Shallotte O'Reilly Auto Parts Client: Project Number: 13287.PE Prepared By: GLM Date: 7/28/14 Basin: DA #1 [PRE] pARAMOUNTE r N C. 1 N 1=_ F_ R I N �. 1 N C. Drainage area= 2.65 acres = 0.004 mi' Area Calculations Land Use Area (Ac.) % of Basin Existing Impervious (Total) = 0.73 27.5% Open Space - Good 1.92 72.5% Sum: 2.65 100% Project Name: Shallotte O'Reilly Auto Parts PA RA MO UNTE Client: Shallotte Developers, LLC Project Number: 13287.PE Prepared By: GLM Date: 7/28/14 Basin: DA #1 [PRE] Drainage area= 2.65 acres = 0.004 miz FA Land Use % of Basin CN A CN B CN C CN D Weighted CN Open Space - Poor 8.0 68 79 86 89 5.57 Open Space - Good 64.5 39 61 74 80 27.27 Impervious 27.5 98 98 98 98 26.95 Sum: 100.0 Sum: 59.80 Curve numbers taken from: TR-55 Use: 60.00 = values input by user = values calculated by spreadsheet Project Name: Shallotte O'Reilly Auto Parts �� - l Client: Shallotte Developers, LLC PA Project Number: 13287.PE Prepared By: GLM Date: 7/28/14 Basin: DA #1 [POST] Drainage area= 2.65 acres = 0.004 miz Area Calculations Land Use Area (Ac.) % of Basin Building (Roof Top) 0.16 Asphalt 0.51 Sidewalk 0.01 Future 0.91 Impervious (Total) = 1.59 60.0% Open Space - Good 1.06 40.0% Sum: 2.65 100% Project Shallotte lly Client Name; Shallo to Devellopers Auto Parts PARA.M.O V .L V TE Project Number: 13287.PE Prepared By: GLM Date: 7/28/14 Basin: DA #1 [POST] Drainage area= 2.65 acres = 0.004 miz r Land Use % of Basin CN A CN B CN C CN D Weighted CN Impervious 60.0 98 98 98 98 58.81 Open Space - Good 40.0 36 60 73 79 15.75 Sum: 100.0 Sum: 74.56 Curve numbers taken from: TR-55 Use: 75 = values input by user = values calculated by spreadsheet Project Name: Client: Project Number: Prepared By: Date: O'Reilly's Shallotte Swain RPB 7/28/14 Average Depth Calculation: (Option 2 per Errata) *Note: Only used areas relative to the main pond Pond #1 ABottom Shelf = 4,592 Sf ABottom Pond = 217 Sf APerm Pool = 6,717 Sf Depth = 7.0 ft daa= 4.1 ft pARA MOUNTE SHALLOTTE O'REILLY AUTO PARTS - WET POND NC DENR Retention Requirements Objective: design a wet detention basin with the following characteristics: a permanent water pool depth between 3- and 6-feet, a surface area that meets TSS removal requirements (values set by NC DENR and included here), a forebay that is approximately 20% of the total pond volume, a temporary water pool sized to detain the initial 1.5 inch of rainfall runoff, an outlet device that drains the temporary water pool within 2-5 days, and a length -to -width ratio of approximately 3:1. Step 1: Determine the surface area required for 90% TSS removal Post -Development Conditions Total Drainage Area 2.65 ACRE Value from CAD Impervious Drainage Area 1.59 ACRE Value from CAD Impervious Cover 60.0% Impervious Cover -(Impervious Drainage Area)/(Total Drainage Area)*100% Elevation of Permanent Pool Surface 4.0 FT Value selected by designer Depth of Permanent Pool 4.0 FT Value selected by designer (Bottom Elevation)=(Permanent Pool Surface Elevation of Wet Detention Pond Bottom -4.0 FT Elevation) -(Depth of Permanent Pool) Approximate Pond Length 132 FT Value from CAD Approximate Pond Width 50 FT Value from CAD Length:Width Ratio 3:1 Ratio=(Length)/(Width):1 Required SAIDA Ratio for 90% TSS Removal 5.30 Value from chart. Reference: 90% TSS Removal Required Surface Area=(Required SAIDA Required Permanent Pool Surface Area 6,118 SF Ratio)*(Total Drainage Area, Provided Permanent Pool Surface Area 6,717 SF Interpolated value from stage -storage calculations Stec, 2: Determine the 1.5-inch runoff elevation within the wet detention pond Runoff Coefficient, Rv 0,590 MIN Rv=0.05+0.009'(%Impervious) Required 1.5 Runoff Volume (Volume of 8,513 CF 1.5 Runoff Volume=l.5 inch'Rv'1 foot/12 Temporary Pool) inch'(Total Drainage Area) Value from stage -storage calculations (cumulative Volume Below Permanent Pool 13,553 CF pond volume at permanent pool elevation) Total Volume to be Controlled=(Volume Below Total Volume to be Controlled 22,066 CF Permanent Pool)+ 1.5" Runoff Volume Value is interpolation based upon stage -storage Storage Elevation at Required Volume 5.25 FT values. See stace-storage calculations Steo 3: Calculate the required forebav volume (18-22% of total pond volume) and compare to the forebay volume provided Total Pond Volume 13,553 CF Value from stage -storage calculations Required Total Forebay Volume 2,711 CIF Forebay Volume=(Total Pond Volume)'20% Provided Total Forebay Volume 2,623 CIF Value from stage -storage calculations Provided Forebay Volume:Total Pond Volume 19% (Provided Forebay Volume)/(Total Pond Volume)'100/ Step 4: Verify that time required to drawdown the 1.5-inch runoff volume is within 2 to 5 days Diameter of Proposed Low -flow Orifice - 1.25 IN Value chosen by designer Elevation of Outlet Structure 5.25 FT Value chosen by designer (Total Elevation Head Above Orifice)=(Weir Total Elevation Head Above Orifice 1.25 FT Elevation) -(Elevation of Permanent Pool Surface) (Average Elevation Head Above Orifice)=((Storage Elevation at Required Volume)+(Elevation of Average Elevation Head Above Orifice 0.42 FT Permanent Pool Surface)]/3-(Storage Elevation at Required Volume) , Cd, Coefficient of Discharge 0.60 Value chosen by designer Q=Cd'(Pi)*[(Diameter of Orifice) *(I ft/12 Q, Flowrate Through Low -flow Orifice g 0.03 CFS in)J^2/4' 2*32.2*(Average Head ^112 (Drawdown Time)=(1. 5" Runoff Volume)/Q'(1 Drawdown Time for 1.5-inch Runoff 3.72 DAYS SHALLOTTE O'REILLY AUTO PARTS Stage -Storage Calculations for Proposed Wet Detention Pond #1 StagelStorage Above Permanent Pool (Including Forebay) Cumulative Contour Incremental Volume, S Contour Area (SF) Volume (CF) (CF) 4.0 6,717 0 0 -Permanent Pool 5.0 7,661 7,189 7,189 6.0 8,644 8,153 15,342 7.0 9,667 9,156 24,497 Stage/Storage Total Pond (Including Forebay) Cumulative Contour Incremental Volume, S Contour Area (SF) Volume (CF) (CF) -5.0 54 - - -Pond Bottom -4.0 217 0 0 -Sediment Storage -3.0 489 353 353 -2.0 880 685 1,038 -1.0 1,388 1,134 2,172 0.0 2,013 1,701 3,872 1.0 2,758 2,386 6,258 2.0 3,620 3,189 9,447 3.0 4,592 4,106 13,553 4.0 6,717 5,655 19,207 -Permanent Pool 5.0 7,661 7,189 26,396 6.0 8,644 8,153 34,549 7.0 9,667 9,156 43,704 Forebay#1 Cumulative Contour Incremental Volume, S Contour Area (SF) Volume (CF) (CF) -3.0 30 - - Bottom Elev. -2.0 104 0 0 -Sediment Storage -1.0 221 163 163 0.0 380 301 463 1.0 584 482 945 2.0 830 707 1,652 3.0 1,111 971 2,623 4.0 1,423 1,267 3,890 Forebay Volume 1 Hydrograph Report Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2009 by Autodesk, Inc. v6.066 Monday, Jul 28, 2014 Hyd. No. 1 Pre Dev Hydrograph type = SCS Runoff Peak discharge = 1.088 cfs Storm frequency = 1 yrs Time to peak = 736 min . Time interval = 1 min Hyd. volume = 6,039 cuft Drainage area = 2.650 ac Curve number = 60 Basin Slope = 0.0 % Hydraulic length = 0 ft Tc method = USER Time of conc. (Tc) = 15.80 min Total precip. = 3.70 in Distribution = Type III Storm duration = 24 hrs Shape factor = 484 Q (cfs) 2.00 1.00 0.00 —' 0 Pre Dev Hyd. No. 1 -- 1 Year 120 240 360 480 600 720 840 960 — Hyd No. 1 Q (cfs) 2.00 1.00 i 1 L 0.00 1080 1200 1320 1440 1560 Time (min) `A Hydrograph Report Hydraflow Hydrographs Extension for AutoCADC Civil 3002009 by Autodesk, Inc. v6.066 Hyd. No. 2 Post Dev Hydrograph type = SCS Runoff Storm frequency = 1 yrs Time interval = 1 min Drainage area = 2.650 ac Basin Slope = 0.0 % Tc method = USER Total precip. = 3.70 in Storm duration = 24 hrs Q (cfs) 5.00 m 3.00 rM 1.00 0.00 -'- 0 120 240 -- Hyd No. 2 Post Dev Hyd. No. 2 -- 1 Year 360 480 600 720 840 Monday, Jul 28, 2014 Peak discharge = 4.563 cfs Time to peak = 725 min Hyd. volume = 14,337 cuft Curve number = 75 Hydraulic length = 0 ft Time of conc. (Tc) = 5.00 min Distribution = Type III Shape factor = 484 Q (cfs) 5.00 4.00 3.00 (Paolo] 1.00 I I--1 ' 0.00 960 1080 1200 1320 1440 1560 Time (min) 3 Hydrograph Report Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2009 by Autodesk, Inc. v6.066 Hyd. No. 3 Wet Pond Hydrograph type = Reservoir Storm frequency = 1 yrs Time interval = 1 min Inflow hyd. No. = 2 - Post Dev Reservoir name = Wet Pond Storage Indication method used. Q (cfs) 5.00 m 3.00 2.00 1.00 0.00 -- 0 300 -•-- Hyd No. 3 Wet Pond Hyd. No. 3 -- 1 Year Monday, Jul 28, 2014 Peak discharge = 0.274 cfs Time to peak = 891 min Hyd. volume = 8,885 cuft Max. Elevation = 5.25 ft Max. Storage = 9,230 cuft 600 900 1200 1500 1800 2100 2400 2700 — Hyd No. 2 Total storage used = 9,230 cult Q (cfs) 5.00 4.00 3.00 2.00 1.00 1 0.00 3000 Time (min) Pond Report 4 r Hydraflow Hydrographs Extension for AutoCAD® Civil 3DO 2009 by Autodesk, Inc. v6.066 Monday, Jul 28, 2014 Pond No. 1 - Wet Pond Pond Data Contours - User -defined contour areas. Conic method used for volume calculation. Begining Elevation = 4.00 It Stage 1 Storage Table Stage (ft) Elevation (ft) Contour area (sqft) Incr. Storage (cuft) Total storage (cuft) 0.00 4.00 6,717 0 0 1.00 5.00 7,661 7,183 7,183 2.00 6.00 8.644 8.147 15.330 3.00 7,00 9.667 9,150 24,480 Culvert 1 Orifice Structures Weir Structures [A] [B] [C] [PrfRsr] [A] [B] [C] [D] Rise (in) = 15.00 1.25 0.00 0.00 Crest Len (ft) = 12.00 20.00 0.00 0.00 Span (in) = 15.00 1.25 0.00 0.00 Crest El. (ft) = 5.25 6.50 0.00 0.00 No. Barrels = 1 1 0 0 Weir Coeff. = 3,33 3.33 3.33 3.33 Invert El. (ft) = 4.00 4.00 0.00 0.00 Weir Type = Riser Ciplti --- --- Length (ft) = 45.00 0.00 0.00 0.00 Multi -Stage = Yes No No No Slope I%) = 0,00 0.00 0.00 n/a N-Value = .013 .013 .013 n/a Orifice Coeff. = 0.60 0.60 0.60 0,60 Exfil.(in/hr) = 0.000 (by Wet area) Multi -Stage = n/a No No No TW Elev. (ft) = 0,00 Note: culvenroahce oddlows are analyzed under inlet (ic) and outlet (cc) control. Weir risers checked for orifice condition. (id) and submergence (s). Stage I Storage I Discharge Table Stage Storage Elevation Clv A Clv B Clv C PrfRsr Wr A Wr B Wr C Wr D Exftl User Total It cuft ft cfs cfs cfs cfs cfs cfs cfs cfs cfs cfs cfs 0,00 0 4.00 0.00 0.00 --- --- 0.00 0,00 --- --- --- --- 0,000 0.10 718 4.10 0.00 0.01 is --- --- 0.00 0,00 --- --- --- --- 0.009 0.20 1,437 4.20 0,00 0,02 is --- --- 0.00 0.00 --- --- --- --- 0.016 0.30 2,155 4.30 0.00 0.02 is --- --- 0.00 0,00 --- --- --- --- 0.020 0.40 2,873 440 0.00 0.02 is --- --- 0.00 0.00 --- --- --- --- 0.024 0.50 3,592 4.50 0.00 0.03 is --- --- 0.00 0,00 --- --- --- --- 0.027 0.60 4,310 4.60 0.00 0.03 is --- --- 0.00 0,00 --- --- --- -- 0.030 0.70 5,028 4,70 0.00 0.03 is --- --- 0.00 0.00 --- --- --- --- 0.033 0.80 5,746 4.80 0.00 0.04 is --- --- 0.00 0.00 --- --- -- --- 0.035 0.90 6,465 4.90 0.00 0.04 is --- --- 0.00 0.00 --- --- --- --- 0.038 1.00 7,183 5.00 0.00 0.04 is --- --- 0.00 0.00 --- --- --- --- 0.040 1.10 7,998 5.10 0.00 0.04 is --- --- 0.00 0.00 --- --- --- --- 0.042 1.20 8,812 5.20 0.00 0.04 is -- --- 0.00 0.00 --- --- --- --- 0.044 1,30 9,627 5.30 0.46 is 0.05 is --- --- 0,45 0.00 --- --- --- --- 0.493 1.40 10,442 5.40 2.32 is 0.05 is --- --- 2.32 0,00 --- --- --- --- 2.369 1.50 11,256 5.50 2.83 oc 0.05 is --- --- 2.83 s 0.00 --- --- --- --- 2.881 1,60 12,071 5.60 3.52 oc 0,05 is --- --- 3.52 s 0.00 --- --- --- --- 3.570 1.70 12,886 - 5.70 4.06 cc 0,05 is --- --- 4.06 s 0,00 --- --- --- - 4.112 1.80 13,701 5.80 4.53 oc 0.05 is - ---- 4.52 s 0.00 --- --- --- --- 4.576 1.90 14,515 5.90 4.95 oc 0.06 is --- --- 4.94 s 0.00 --- --- --- --- 4.993 2.00 15,330 6.00 5.33 oc 0.06 is -- --- 5.30 s 0.00 --- --- --- --- 5.359 2.10 16,245 6.10 5.68 oc 0.06 is --- --- 5.67 s 0.00 --- --- --- --- 5.727 2.20 17,160 6.20 6.01 oc 0.06 is --- --- 5.99 s 0.00 --- --- -- --- 6.050 2.30 18,075 6.30 6.32 cc 0.06 is --- --- 6.31 s 0.00. -- --- --- --- 6.374 2.40 18,990 6.40 6.62 oc 0.06 is --- --- 6.58 s 0.00 --- --- --- --- 6.638 2.50 19,905 6.50 6.90 oc 0,06 is -- --- 6.86 s 0.00 --- --- --- --- 6,928 2.60 20,820 6.60 7.18 cc 0.07 is --- --- 7.15 s 2.11 --- --- --- - 9,320 2.70 21,735 6.70 7.44 oc 0.07 is --- --- 7.35 s 5,96 --- --- --- -- 13.38 2,80 22.650 6.80 7,69 oc 0.07 is --- --- 7.58 s 10.94 --- --- --- --- 18,59 2,90 23,565 6.90 7.94 oc 0.07 is --- --- 7.87 s 16.85 --- --- --- --- 24.79 100 24,480 7.00 8.17 cc 0,07 is --- --- 8.12 s 23.55 --- --- --- --- 31.74 Hydrograph Report 5 Hydra Flow Hydrographs Extension for AutoCAD® Civil 3DO 2009 by Autodesk, Inc. v6.066 Hyd. No. 1 Pre Dev Hydrograph type = SCS Runoff Storm frequency = 10 yrs Time interval = 1 min Drainage area = 2.650 ac Basin Slope = 0.0 % TIC method = USER Total precip. = 7.00 in Storm duration = 24 hrs Q (CIS) 6.00 5.00 Me c m 2.00 1.00 Pre Dev Hyd. No. 1 -- 10 Year Monday, Jul 28, 2014 Peak discharge = 5.942 cfs Time to peak = 732 min Hyd. volume = 25,358 cuft Curve number = 60 Hydraulic length = 0 ft Time of conc. (Tc) = 15.80 min Distribution = Type III Shape factor = 484 Q (Cfs) 6.00 5.00 4.00 3.00 2.00 1.00 0.00 1 1 1 _I 1 1 i I I I 1 t 0.00 0 120 240 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) -- Hyd No. 1 11 Hydrograph Report Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2009 by Autodesk, Inc. v6.066 Monday, Jul 28, 2014 Hyd. No. 2 Post Dev Hydrograph type = SCS Runoff Peak discharge = 13.33 cfs , Storm frequency = 10 yrs Time to peak = 725 min Time interval = 1 min Hyd. volume = 41,163 cuft Drainage area = 2.650 ac Curve number = 75 Basin Slope = 0.0 % Hydraulic length = 0 ft Tc method = USER Time of conc. (Tc) = 5.00 min Total precip. = 7.00 in Distribution = Type III Storm duration = 24 hrs Shape factor = 484 Post Dev Hyd. No. 2 -- 10 Year 12.00 10.00 We 2.00 Q (Cfs) 14.00 12.00 10.00 . 11 2.00 0.00 ---- —_ _. _ _ ____.I —^r I I I 1r-- - 0.00 0 120 240 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) — Hyd No. 2 Hydrograph Report 7 Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2009 by Autodesk, Inc. v6.066 Hyd. No. 3 Wet Pond Hydrograph type = Reservoir Storm frequency = 10 yrs Time interval = 1 min Inflow hyd. No. = 2 -Post Dev Reservoir name = Wet Pond Storage Indication method used. Q (cfs) 14.00 12.00 10.00 no .M M M Wet Pond Hyd. No. 3 -- 10 Year Monday, Jul 28, 2014 Peak discharge = 5.273 cfs Time to peak = 739 min Hyd. volume = 35,659 cuft Max. Elevation = 5.98 ft Max. Storage = 15,137 cult Q (cfs) 14.00 12.00 10.00 . 11 2.00 0.00 - 0.00 0 120 240 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) -- Hyd No. 3 — Hyd No. 2 Total storage used = 15,137 cuff 4 8 Hydrograph Report I Hydraflow Hydrographs Extension for AutoCADB Civil 3D® 2009 by Autodesk, Inc. v6.066 Hyd. No. 1 Pre Dev Hydrograph type = SCS Runoff Storm frequency = 100 yrs Time interval = 1 min Drainage area = 2.650 ac Basin Slope = 0.0 Tc method = USER Total precip. = 10.50 in Storm duration = 24 hrs 0 (cfs) 14.00 12.00 10.00 M M r �� Pre Dev Hyd. No. 1 -- 100 Year Monday, Jul 28, 2014 Peak discharge = 12.47 cfs Time to peak = 732 min Hyd. volume = 51,689 cuft Curve number = 60 Hydraulic length = 0 ft Time of conc. (Tc) = 15.80 min Distribution = Type III Shape factor = 484 0 (cfs) 14.00 12.00 � IP M .w IN 2.00 0.00 -1 — I -- —I I ---r I I I I i 1 ten! 0.00 0 120 240 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) —• Hyd No. 1 Hydrograph Report 0 Hydraflow Hydrographs Extension for AutoCADO Civil 3DO 2009 by Autodesk, Inc. v6.066 Hyd. No. 2 Post Dew Hydrograph type = SCS Runoff Storm frequency = 100 yrs Time interval = 1 min Drainage area = 2.650 ac Basin Slope = 0.0 % Tc method = USER Total precip. = 10.50 in Storm duration = 24 hrs Q (cfs) 24.00 20.00 16.00 12.00 : 11 4.00 Post Dev Hyd. No. 2 -- 100 Year Monday, Jul 28, 2014 Peak discharge = 23.21 cfs Time to peak = 724 min Hyd. volume = 72,852 cuft Curve number = 75 Hydraulic length = 0 ft Time of conc. (Tc) = 5.00 min Distribution = Type III Shape factor = 484 Q (cfs) 24.00 20.00 16.00 12.00 4.00 0.00 1 1l_ _.1. 1 1 1 1 — �:.__— 1 0.00 0 120 240 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) — Hyd No. 2 MO Hydrograph Report Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2009 by Aulodesk, Inc. v6.066 Monday, Jul 28, 2014 Hyd. No. 3 Wet Pond Hydrograph type = Reservoir Peak discharge = 15.24 cfs Storm frequency = 100 yrs Time to peak = 730 min Time interval = 1 min Hyd. volume = 67,319 cuft Inflow hyd. No. = 2 -Post Dev Max. Elevation = 6.74 ft Reservoir name = Wet Pond Max. Storage = 22,061 cuft Storage Indication method used. Wet Pond Q cfs Q (cfs) ( ) Hyd. No. 3 -- 100 Year 24.00 24.00 20.00 20.00 16.00 16.00 12.00 12.00 8.00 8.00 4.00 4.00 0.00 -- -- — .-. __. __. 0.00 0 120 240 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) ---- Hyd No. 3 — Hyd No. 2 Total storage used = 22,061 cuft -Elm oa.vv�m�vrt orixevrrn�aa exwmnpuwuHa�a w.w4sMYY.�.Yy+.-1 ^-_rzaaa YY[I:NOL