HomeMy WebLinkAboutSW8000630_CURRENT PERMIT_20220921STORMWATER DIVISION CODING SHEET
POST -CONSTRUCTION PERMITS
PERMIT NO.
SW8 000ko3 b
DOC TYPE
® CURRENT PERMIT
❑ APPROVED PLANS
❑ HISTORICAL FILE
❑ COMPLIANCE EVALUATION INSPECTION
DOC DATE
2022 0 ot 21
YYYYMMDD
STATE OF NORTH CAROLINA, Department of Environmental Quality,
127 Cardinal Drive Extension, Wilmington, North Carolina 28405 (910) 796-7215
FILE ACCESS RECORD
DEQ SECTION: 'D E M'r 1,_SL REVIEW TIME / DATE: L, L y '7-o % ?s 6) q un
NAME: KQ\ ���11SYU�l EMA1L:_�.C�U(�S1 u� a� V�1 d1!-KSon. (Gm
REPRESENTING: W� DIGKSU(\ a (Q J�� PHONE: C� \1- LA
Guidelines for Access: The staff of Wilmington Regional Office is dedicated to making public records in our custody readily
available to the public for review and copying. We also have the responsibility to the public to safeguard these records and to carry
out our day -today program obligations. Please read carefully the following guidelines signing the form:
1. Due to the large public demand for file access, we request that you call at least a day in advance to schedule an
appointment to review the files. Appointments will be scheduled between 9:00am and 3:00pm. Viewing time ends at
4:45pm_ done arrivine without an appointment may view the files to the extent that time and staff supervision
is available.
2. You must specify files you want to review by facility name- The number of files that you may review at one time will
be limited to five.
3.
4. You may make copies of a file at $.05 per copy. First 100 copies at no charge. Payment may be made by check or
money order at the reception desk. You may also scan to email or a thumb drive_
5. FILES MUST BE KEPT IN ORDER YOU FOUND THEM. Files may not be taken from the office. To remove,
alter, deface, mutilate, or destroy material in one of these files is a misdemeanor for which you can be fined up to
$500.00_ No briefcases, large totes etc. are permitted in the file review area
6. You may take photos of large plans with your phone camera Necessary large plan copies can be scheduled with
Cameron. WeaverQ4cdear.Qov 910-796-7265 for a later date/time at an offsite location at your expense. Requests for
large plan copies should be attached on top of the file after completion of the review. Allways Graphics can be contacted
to set up payment options.
7. Written questions may be left with this completed form and a staff member will be in contact with you IF you
provide your contact information where indicated above.
8. In accordance with General Statue 25-3-512, a $25.00 processing fee will be charged and collected for checks on which
payment has been refused -
FACILITY NAME COUNTY
1. 5v1$ IO0SW g 11+G9G1 t>\- o Oe123V
2- SvAs Hog Q K .SW $ oflo 0-1 03 S`NS `1 RO`i 12
3. Sr1P !nuOC9 SW$2ZU311,S'4zcw-7io,
4. sl� 2'Zwzk�p, Itwo R3 DWG S\W5 )2.0,,00�1
5. c.,JS( 220b1r, Sv14 O"ll0lz V.J4 OClhkz3C)
w� j pv(oti23
of FinnMusiness Date MM/DD/YY Time In TimeOut
COPIES MADE PAID INVOICE
G:/ADM/Shared/Fiic Review Access Form rev 2022
ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
BRIAN WRENN
Director
September 21, 2022
Crown Management Corporation
Previously known as Crown Box Corporation
Attn: Harry L. Kraly, President
2406 N. 231d Street
Wilmington, NC 28401
NORTH CAROLINA
Environmental Quality
Subject: Permit Renewal
Post -Construction Stormwater Management Permit No. SW8 000630
Federal Express Ground
New Hanover County
Dear Mr. Kraly:
Effective August 1, 2013 the Post -Construction Stormwater Management Program has been transferred from the
Division of Water Quality ("DWQ") to the Division of Energy, Mineral and Land Resources ("DEMLR"). All
previous references to DWQ will remain in older permits issued prior to August 1, 2013 until they are modified.
Please note that this permit will now reference DEMLR as the Division responsible for enforcement of the permit.
The Division of Energy, Mineral and Land Resources received a complete Permit Renewal Application and two
(2) fees for the subject permit renewal total of 16-years on August 24, 2022. The Division is hereby notifying you
that permit SW8000630 has been renewed, updated, and re -issued on September 21, 2022, as attached. Please be
aware that the renewal and re -issuance of this stormwater permit does not Imply that the site is currently in
compliance.
This permit shall be effective until October 19, 2030 and does not supersede any other agency permit that may be
required. The project shall be subject to the conditions and limitations as specified therein. This permit does not
impose new or increased stormwater control requirements; it clarifies the rules and requirements of this program
to provide you with a better understanding of your obligations under this permit. Failure to comply with these
requirements will result in future compliance problems. Please note that this permit is not transferable except
after notice to and approval by the Division.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request
an adjudicatory hearing by filing a written petition with the Office of Administrative Hearings (OAH). The
written petition must conform to Chapter 150B of the North Carolina General Statutes and must be filed with the
OAH within thirty (30) days of receipt of this permit. You should contact the OAH with all questions regarding
the filing fee (if a filing fee is required) and/or the details of the filing process at 6714 Mail Service Center,
Raleigh, NC 27699-6714, or via telephone at 919-431-3000, or visit their website at www.NCOAH.com. Unless
such demands are made this permit shall be final and binding.
If you have any questions concerning this permit, please contact Ashley Smith in the Wilmington Regional
Office, at (910) 796-7215 or ashleym.smith@nedenr.gov.
Sincerely,
clka Wip
Brian Wrenn, Director
Division of Energy, Mineral and Land Resources
®� � North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources
Wilmington Regional Office 1 127 Cardinal Drive Extension I Wilmington, North Carolina 28405
910.796.7215
State Stormwater Permit No. SW8 000630
Page 2 of 2
Enclosures: Attachment C —Permitting History
copy of the Renewal Application Documents
DES/arms: WStormwaterWermits & Projects\2000\000630 HD\2022 doc mo permit 000630
CC' Phillip G. Tripp, PE; Tripp Engineering, P.C.; 419 Chestnut Street, Wilmington, NC 28401
Wilmington Regional Office Stormwater File
�v North Carolina Department of Envimnmental Quality I Division of Energy. Mneml and Land Resources
_ Wilmington Regional Office 1 127 Cardinal Drive Extension I Wilmington, North Carolina 28405
910.796.7215
Post -Construction Stormwater Management
Permit No. SW8 000630
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENTAL QUALITY
DIVISION OF ENERGY, MINERAL AND LAND RESOURCES
POST -CONSTRUCTION STORMWATER MANAGEMENT PERMIT
HIGH DENSITY DEVELOPMENT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as
amended, and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Crown Box Corporation
Federal Express Ground
2414 N. 23' Street, Wilmington, New Hanover County
FOR THE
construction, operation and maintenance of a wet detention basin in compliance with the provisions of
15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules') and as outlined in the
application, approved stormwater management plans, supplement, calculations, operation and
maintenance agreement, recorded documents, specifications, and other supporting data (the
"approved plans and specifications") as attached and/or on file with and approved by the Division of
Energy, Mineral and Land Resources (the "Division" or "DEMLR"). The project shall be constructed,
operated and maintained in accordance with these approved plans and specifications. The approved
plans and specifications are incorporated by reference and are enforceable part of this permit.
This permit shall be effective from the date of issuance until October 19, 2030 and shall be subject to
the following specified conditions and limitations. The permit issued shall continue in force and effect
until the permittee files a request with the Division for a permit modification, transfer, renewal, or
rescission, however, these actions do not stay any condition. The issuance of this permit does not
prohibit the Director from reopening and modifying the permit, revoking and reissuing the permit, or
terminating the permit for cause as allowed by the laws, rules, and regulations contained in Title 15A
NCAC 2H.1000 and NCGS 143-215.1 et.al.
I. DESIGN STANDARDS
This permit is effective only with respect to the nature and volume of stormwater described in
the application and other supporting data.
2. This stormwater system has been approved for the management of stormwater runoff as
described on page 2 of this permit. The stormwater control has been designed to handle the
runoff from 127,744 square feet of impervious area.
The tract will be limited to the amount of built -upon area indicated on page 2 of this permit, and
per approved plans.
Page 1 of 5
Post -Construction Stormwater Management
Permit No. SW8 000630
DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES
Project Name:
Permit Number:
Location:
Applicant:
Mailing Address:
Application Date:
Name of Receiving Stream/Index #:
Classification of Water Body:
If Class SA, chloride sampling results:
Pond Depth, feet:
Permanent Pool Elevation, FMSL:
Drainage Area, acres:
Total Impervious Surfaces, ftl:
Buildings, ftz:
Parking, ftl:
Sidewalks, ftl:
Offsite Area entering Pond, ftl:
Required Surface Area, ftl:
Provided Surface Area, ftl:
Required Storage Volume, ft':
Provided Storage Volume, ft':
Temporary Storage Elevation, FMSL:
Controlling Orifice:
II. SCHEDULE OF COMPLIANCE
Federal Express Ground
SW8 000630
New Hanover County
Mr. Harry L. Kraly, President
Crown Management Corporation
2406 N. 231 Street
Wilmington, NC 28401
August 24, 2022
UT Smith Creek / 18-74-63
"C Sw"
n/a
7.00
18.00
3.19
127,744
15,375
103,932
8,740
none, per Engineer
5,527
6,740
10,160
16,040
20.00
1.50" cp pipe
The stormwater management system shall be constructed in it's entirety, vegetated and
operational for its intended use prior to the construction of any built -upon surface.
During construction, erosion shall be kept to a minimum and any eroded areas of the system
will be repaired immediately.
3. The permittee shall at all times provide the operation and maintenance necessary to assure
the permitted stormwater system functions at the design condition. The approved Operation
and Maintenance Plan must be followed in its entirety and maintenance must occur at the
scheduled intervals including, but not limited to:
a. Semiannual scheduled inspections (every 6 months).
b. Sediment removal.
C. Mowing and revegetation of side slopes.
d. Immediate repair of eroded areas.
e. Maintenance of side slopes in accordance with approved plans and specifications.
f. Debris removal and unclogging of outlet structure, orifice device and catch basins and
piping.
g. Access to the outlet structure must be available at all times.
4. Records of maintenance activities must be kept and made available upon request to
authorized personnel of DEMLR. The records will indicate the date, activity, name of person
performing the work and what actions were taken.
5. Decorative spray fountains will not be allowed in the stormwater treatment system, as the
permanent pool volume is less than 30,000 cubic feet.
Page 2 of 5
Post -Construction Stormwater Management
Permit No. SW8 000630
6. The facilities shall be constructed, operated and maintained in accordance with the provisions
of this permit, the approved plans and specifications, and the supporting documents attached
to this permit and on file with the Division.
Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to
operation of this permitted facility, a certification must be received from an appropriate
designer for the system installed certifying that the permitted facility has been installed in
accordance with this permit, the approved plans and specifications, and other supporting
documentation. Any deviations from the approved plans and specifications must be noted on
the Certification. A modification may be required for those deviations.
If the stormwater system was used as an Erosion Control device, it must be restored to design
condition prior to operation as a stormwater treatment device, and prior to occupancy of the
facility.
9. Prior to the sale of any portion of the property, an access/maintenance easement to the
stormwater facilities shall be granted in favor of the permittee if access to the stormwater
facilities will be restricted by the sale of any portion of the property.
10. The permittee is responsible for verifying that the proposed built -upon area does not exceed
the allowable built -upon area.
11, The runoff from all built -upon area on the project must be directed into the permitted
stormwater control system.
12. The Director may notify the permittee when the permitted site does not meet one or more of
the minimum requirements of the permit. Within the time frame specified in the notice, the
permittee shall submit a written time schedule to the Director for modifying the site to meet
minimum requirements. The permittee shall provide copies of revised plans and certification in
writing to the Director that the changes have been made.
13. No person or entity, including the permittee, shall alter any component shown in the approved
plans and specifications. Prior to the construction of any modification to the approved plans,
the permittee shall submit to the Director, and shall have received approval for modified plans,
specifications, and calculations including, but not limited to, those listed below. For changes to
the project or SCM that impact the certifications, a new or updated certification(s), as
applicable, will be required and a copy must be submitted to the appropriate DEQ regional
office upon completion of the modification.
a. Any modification to the approved plans and specifications, regardless of size including
the SCM(s), BUA, details, etc.
b. Redesign or addition to the approved amount of BUA or to the drainage area.
C. Further development, subdivision, acquisition, lease or sale of any, all or part of the
project and/or property area as reported in the approved plans and specifications.
d. Altering, modifying, removing, relocating, redirecting, regrading, or resizing of any
component of the approved SCM(s), the stormwater collection system and/or
vegetative conveyance shown on the approved plan.
e. The construction of any allocated future BUA.
f. The construction of any permeable pavement, #57 stone area, public trails, or
landscaping material to be considered a permeable surface that were not included in
the approved plans and specifications.
g. Other modifications as determined by the Director.
III. GENERAL CONDITIONS
CORRECTIVE ACTIONS REQUIRED. If the facilities fail to perform satisfactorily, the
permittee shall take immediate corrective actions. This includes actions required by this
Division and the stormwater rules such as the construction of additional or replacement on -site
stormwater systems. These additional or replacement measures shall receive a permit from
the Division prior to construction.
Page 3 of 5
Post -Construction Stormwater Management
Permit No. SW8 000630
2. PERMIT RENEWAL. A permit renewal request must be submitted at least 180 days prior to
the expiration date of this permit. The renewal request must include the appropriate
application, documentation and the processing fee as outlined in Title 15A NCAC
02H.1045(3).
3. CHANGES TO THE PROJECT NAME, PERMITTEE NAME OR CONTACT INFORMATION.
The permittee shall submit a completed Permit Information Update Application Form to the
Division within 30 days to making any one of these changes.
4. TRANSFER. This permit is not transferable to any person or entity except after notice to and
approval by the Director. Neither the sale of the project and/or property, in whole or in part, nor
the conveyance of common area to a third party constitutes an approved transfer of the permit.
a. TRANSFER REQUEST. The transfer request must include the appropriate application,
documentation and the processing fee as outlined in 15A NCAC 02H.1045(2). This
request must be submitted within 90 days of the permit holder meeting one or more of the
following:
i. A natural person who is deceased,
ii. A partnership, limited liability corporation, corporation, or any other business
association that has been dissolved;
iii. A person or entity who has been lawfully and finally divested of title to the property
on which the permitted activity is occurring or will occur through foreclosure,
bankruptcy, or other legal proceeding.
iv. A person or entity who has sold the property, in whole or in part, on which the
permitted activity is occurring or will occur,
v. The assignment of declarant rights to another individual or entity;
vi. The sale or conveyance of the common areas to a Homeowner's or Property
Owner's Association, subject to the requirements of NCGS 143-214.7(c2),
b. TRANSFER INSPECTION. Prior to transfer of the permit, a file review and site inspection
will be conducted by Division personnel to ensure the permit conditions have been met and
that the project and the on -site stormwater system complies with the permit conditions.
Records of maintenance activities performed to date may be requested. Projects not in
compliance with the permit will not be transferred until all permit and/or general statute
conditions are met.
COMPLIANCE. The permittee is responsible for compliance with the terms and conditions of
this permit until the Division approves the transfer request.
a. APPROVED PLANS AND SPECIFICATIONS. A copy of this permit, approved plans,
application, supplement, operation and maintenance agreement, all applicable recorded
documents, and specifications shall be maintained on file by the permittee at all times.
b. DIVISION ACCESS. The permittee grants Division Staff permission to enter the property
during normal business hours to inspect all components of the permitted project.
c. ENFORCEMENT. Any individual or entity found to be in noncompliance with the provisions
of a stormwater management permit or the requirements of the stormwater rules is subject
to enforcement procedures as set forth in NCGS 143 Article 21.
d. ANNUAL CERTIFICATION. The permittee shall electronically submit to the Division an
annual certification completed by either the permittee or their designee confirming the
projects conformance with permit conditions
e. OBTAINING COMPLIANCE. The Director may notify the permittee when the permitted
site does not meet one or more of the minimum requirements of the permit. Within the time
frame specified in the notice, the permittee shall submit a written time schedule to the
Director for modifying the site to meet minimum requirements. The permittee shall provide
copies of modified plans and certification in writing to the Director that the changes have
been made.
Page 4 of 5
Post -Construction Stormwater Management
Permit No. SW8 000630
OTHER PERMITS. The issuance of this permit does not preclude the permittee from
complying with and obtaining any other permits or approvals that are required for this
development to take place, as required by any statutes, rules, regulations, or ordinances,
which may be imposed by any other Local, State or Federal government agency having
jurisdiction. Any activities undertaken at this site that cause a water quality violation or
undertaken prior to receipt of the necessary permits or approvals to do so are considered
violations of NCGS 143-215.1, and subject to enforcement procedures pursuant to NCGS
143-215.6.
Permit renewed, updated and reissued this the 21st day of September 2022.
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
7-, Brian Wrenn, Director
Division of Energy, Mineral and Land Resources
By Authority of the Environmental Management Commission
Permit Number SW8 000630
Page 5 of 5
Attachment C- Permitting History
Federal Express Ground
Permit No. SW8 000630
Approval
Permit
BIMS .
Description of the Changes
Date
Action
Version
construction, operation and maintenance of a wet detention
Original
basin in compliance with the provisions of 15A NCAC 2H
10/19/2000
Approval
1.0
1000; The stormwater control has been designed to handle the
runoff from 127,744 square feet of impervious area.
reallocating impervious area for onsite buildings, onsite
7/l/2013
Plan
1.1
parking/asphault, onsite sidewalks/concrete and future
Revision
,allocations
double renewal, previous permit expires October 19, 2022 and
9/21/2022
Renewal
2.0
renewal applications are due 180 prior to expiration
9/21/2022
Renewal
3.0
Expires October 19, 2030
10/77/1996 06:47 9107635631 TRIPP ENGINEERING PAGE 02
Permit No.
(to be provided by DWQ)
State of North Carolina
Department of Environment and Natural Resources
Division of water Quality
STORMWATER MANAGEMENT PERMIT APPLICATION FORM
WET DETENTION BASIN SUPPLEMENT
This form maybe photocopied for vse as an original
DWO Stormwater Management Plan Review:
A complete stormwater management plan submittal includes a wet detention basin supplement for each basin,
design calculations, plans and specifications showing all basin and outlet structure details, and a signed and
notarized operation and maintenance agreement.
I. PROJECT INFORMATION (please complete the following information):
Project Name: Federal Express Ground
Contact Person: P i11in Tripp Phone Number. (910 ) 763-5100
For projects with multiple basins, specify which basin this worksheet applies to: 1
elevations
Basin Bottom Elevation 11.0 ft. (floor of the basin)
Permanent Pool Elevation 18,0 ft. (elevation of the orifice)
Temporary Pool Elevation 20.0 ft. (elevation of the discharge structure overflow)
areas
Permanent Pool Surface Area 6,740_ sq.ft.
Drainage Area 3 19 ac.
Impervious Area 2.93 ac•
(water surface area at the orifice elevation)
(on -site and off -site drainage to the basin)
(on -site and off -site drainage to the basin)
volumes
Permanent Pool Volume 18.651� cu.ft. (combined volume of main basin and forebay)
Temporary Pool Volume _16.040 cu.ft. . (volume detained above the permanent pool)
Forebay Volume 3.975 cu.ft. (approximately 20% of total volume)
Other parameters
SA/DA' 4.02 (surface area to drainage area ratio from DWQ table)
Diameter of Orifice _
1.5 in. (2 to 5 day temporarypool draw -down required)
Design Rainfall in.
Design TSS RemovalZ _�_ % (minimum 85 % required)
Form SW-102 Rev 3.99 Page 1 of 4
Footnotes:
1. When using the Division SA/DA tables, the correct SA/DA ratio for permanent pool sizing should be computed based upon the
actual impervious % and permanent pool depth. Linear interpolation should be employed to determine the correct value for non-
standard table entries.
2. In the 20 coastal counties, the requirement for a vegetative filter may be waived if the wet detention basin is designed to provide
90% TSS removal. The NCDENR BMP manual provides design tables for both 85% TSS removal and 90% TSS removal.
it. REQUIRED ITEMS CHECKLIST
The following checklist outlines design requirements per the Stormwater Best Management Practices Manual
(N.C. Department of Environment, Health and Natural Resources, February 1999) and Administrative Code
Section: 15 A NCAC 2H .1008.
Initial in the space provided to indicate the following design requirements have been met and supporting
documentation is attached. If the applicant has designated an agent in the Stormwater Management Permit
Application Form, the agent may initial below. If a requirement has not been met, attach justification.
Applicants Initials
'ea. The permanent pool depth is between 3 and 6 feet (required minimum of 3 feet).
C-'� b. The forebay volume is approximately equal to 20% of the total basin volume.
CV& c. The temporary pool controls runoff from the design storm event.
d. The temporary pool draws down in 2 to 5 days.
NA e. If required, a 30-foot vegetative filter is provided at the outlet (include non -erosive flow
calculations).
t f. The basin length to width ratio is greater than 3:1.
C[aG g. The basin side slopes above the permanent pool are no steeper than 3:1.
G.CC. It. A submerged and vegetated perimeter shelf with a slope of 6:1 or less (show detail).
GCG i. Vegetative cover above the permanent pool elevation is specified.
d4prl j. A trash rack or similar device is provided for both the overflow and orifice.
<32!-, k. A recorded drainage easement is provided for each basin including access to nearest right-
of-way.
G!5r 1. If the basin is used for sediment and erosion control during construction, clean out of the
basin is specified to be performed prior to use as a wet detention basin
(mow m. A mechanism is specified which will drain the basin for maintenance or an emergency.
III. WET DETENTION BASIN OPERATION AND MAINTENANCE AGREEMENT
The wet detention basin system is defined as the wet detention basin, pretreatment including forebays and the
vegetated filter if one is provided.
This system (check one) ❑ does X does not incorporate a vegetated filter at the outlet.
This system (check one) ❑ does X does not incorporate pretreatment other than a forebay.
Form SWU-102 Rev 3.99 Page 2 of 4
Maintenance activities shall be performed as follows:
After every significant runoff producing rainfall event and at least monthly:
a. Inspect the wet detention system for sediment accumulation, erosion, trash accumulation,
vegetated cover, and general condition.
b. Check and clear the orifice of any obstructions such that drawdown of the temporary pool occurs
within 2 to 5 days as designed.
2. Repair eroded areas immediately, re -seed as necessary to maintain good vegetative cover, mow vegetative
cover to maintain a maximum height of six inches, and remove trash as needed.
3. Inspect and repair the collection system (i.e. catch basins, piping, swales, riprap, etc.) quarterly to
maintain proper functioning.
4. Remove accumulated sediment from the wet detention basin system semi-annually or when depth is
reduced to 75% of the original design depth (see diagram below). Removed sediment shall be disposed
of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality
(i.e. stockpiling near a wet detention basin or stream, etc.).
The measuring device used to determine the sediment elevation shall be such that it will give an accurate
depth reading and not readily penetrate into accumulated sediments.
When the permanent pool depth reads 5.25 feet in the main pond, the sediment shall be removed.
When the permanent pool depth reads 2.25 feet in the forebay, the sediment shall be removed.
BASIN DIAGRAM
(Fill in the blanks)
Permanent Pool Elevation 18.0
Sediment R moval El. 15.75 75 0
Sediment Removal Elevation 12.75 75/°
Bottom evation 15.0 %---------------------------------------------- --o-
Bottom Elevation 11.0 25 /y
FOREBAY MAIN POND
Remove cattails and other indigenous wetland plants when they cover 50% of the basin surface. These
plants shall be encouraged to grow along the vegetated shelf and forebay berm.
6. If the basin must be drained for an emergency or to perform maintenance, the flushing of sediment
through the emergency drain shall be minimized to the maximum extent possible.
Form SWU-102 Rev 3.99 Page 3 of 4
7. All components of the wet detention basin system shall be maintained in good working order.
I acknowledge and agree by my signature below that I am responsible for the performance of the seven
maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any
changes to the system or responsible party.
Print name:
Title: Vice -President
Address: P.O. Box 2538, Wilmington, NC 28401
Phone
Signai
Date:
Note: The legally responsible party should not be a homeowners association unless more than 50% of the lots have been sold and
a resident of the subdivision has been named the president.
I, Monica V. Loughlin , a Notary Public for the State of North Carolina ,
County of New Hanover , do hereby certify that Harry L. Kraly
personally appeared before me this Af!jd day of ��¢ 2000 and acknowledge the due
execution of the forgoing wet detention basin maintenance requirements. Witness my hand and official seal,
0 TAl;y
:US
jDUBOr' r='
E�R�tt\\�s0p r
SEAL
My commission expires 08/07/01
Form SWU-102 Rev 3.99 Page 4 of 4
,._--UtMLKU5t'UNLY.-._ .
Date R ceived Fee Paid Permit Number
ene a s - 505eac
NC DEQ Division of Energy, Mineral and Land Resources
STATE STORMWATER:
PERMIT RENEWAL APPLICATION FORM
In accordance with 15A NCAC 2H.1045(3), the current permit holder shall renew their high density permit 180 days
prior to its expiration. Renewed permits are valid for a period of 8 years per Session Law 2011-398 (SB 781)
Section 60.(c). This application form is for permit renewals only.
A. PROJECT INFORMATION
1. State Stormwater Permit Number: SW8 000630
2. Project name: Federal Express Ground
3. Project street address: 2414 N. 23`d Street
City: Wilmington County: New Hanover
ZIP: 28401
4. What, if any, changes have been made to the project as permitted?
If the project has changed from the original approved plans, please complete SWU-101 for a Major
Modification or Minor Modification Application form available at: https://deg.nc,govlabouUdivisions/energy-
mineral-land-resources/energy-mineral-land-rules/stormwater-program/post-construction.
B. PERMITTEE INFORMATION
If changes to the permittee or project name have been made, please complete either the Permit Update form
or the Permit Transfer form available at: https //deg nc gov/about/divisions/enerqv-mineral-land-
resources/energy-mineral-land-rules/stormwater-prograin/post-construction. State Stormwater Permits do not
automatically transfer with the sale of the property.
1. Current Permit Holder's Company Name/Organization: Crown Management Corporation (formerly_
Crown Box Corporation)
2. Signing Official's Name: Harry L. Kraly
3. Signing Official's Title: President
4. Mailing Address: 2406 N. 23rd Street
City: Wilmington State: NC ZIP':
28401
5. Street Address: 2406 N. 23`d Street
City: Wilmington State: NC ZIP
28401
6. Phone: (910) 231-2874 Email: kralvhI(L gmail.com
AU6 2 4 2022
BY:___
Stormwater Permit Renewal Form Page 1 of 3 May 11, 2018
C. SUBMITTAL REQUIREMENTS
Submit the application package to the appropriate DEMLR Regional Office (Coastal, SA Waters) orDEMLR
Central Office (Urbanizing Areas Ph 2, USMP, Non -Coastal HQW/ORW). Only applications packages that
include all required items listed below will be accepted and reviewed.
Initial each item below to indicate that the required information is provided in the application package:
A��11v 1. A permit application processing fee of $505.00 payable to NCDEQ.
/!Cr 2. One original signed hard copy and one electronic copy of this completed form. The signing official
named on this application to represent the current permittee must meet one of the following:
a. Corporation — a principle executive officer of at least the level of vice-president;
b. Limited Liability Company (LLC) — a manager or company official as those terms are defined
in G.S. 57D "North Carolina Limited Liability Company Act,"
c. Public Entity — a principal executive officer, ranking official, or other duly authorized employee,
d. Partnership or limited partnership — the general partner;
e. Sole proprietor; or
f. Letter of authorization signed by one of the signatories noted in a — e above authorizing the
signature of another entity.
il✓,4 3. One hard copy and one electronic copy of recorded documents required by the original permit that
have not yet been received by DEMLR, including: deed restrictions, protective covenants,
condominium/planned community declaration and easements. If the project has been built, include
documentation that the maximum BUA per lot or maximum total BUA has not been exceeded. If
the project has not been built, include a signed agreement that the final recorded deed restrictions
p and protective covenants will be submitted at a later date.
4. O&M Agreements, Please select one:
® I have a copy of the current recorded O&M Agreement for all SCMs, and I will continue to
keep this on file with the permit; or
❑ I do not have a copy of the current recorded O&M Agreement for all SCMs and am
requesting a copy be sent to me. I agree to keep this on file with the permit.
Alt t 5. Designer Certifications, Please select one:
❑ A copy of the certification(s) confirming that the project was built in accordance with the
approved plans have been previously provided to the Division, or
® A copy of the certification(s) confirming that the project was built in accordance with the
approved plans are enclosed; or
❑ The project has not yet been built.
�1"�✓� 6. [IF APPLICABLE) If the project has been built, one original hard copy and one electronic copy of a
signed, sealed, and dated letter from a licensed professional stating that the SCMs have been
inspected, and that they have been built and maintained in accordance with the permit.
7. [IF APPLICABLE] When the permittee is a corporation or a limited liability corporation (LLC):
Provide one hard copy and one electronic copy of documentation from the NC Secretary of State,
or other official documentation, which supports the titles and positions held by the persons listed in
Section C.2 per 15A NCAC 2H. 1043(3)(b).
https://www.sosnc,gov/online services/search/by title/ Business Registration
AUG 2 4 2022 i
By:—__.___—
Stormwater Permit Renewal Application Form Page 2 of 3 May 11, 2018
D. PERMITTEE'S CERTIFICATION
1, 4(2014 [ 111IR14 , the person legally responsible for the permit, certify that I have
a copy of thdPermit and O&M Agreement on site (or I will obtain a copy and it will be kept on site), that I am
responsible for the performance of the maintenance procedures, and the site has been and will be maintained
according to the O&M Agreement and approved plans. I agree to notify DEMLR of any problems with the SCMs
or built -upon area and to submit the proper forms to modify or transfer the permit prior to any changes to the
project, SCMs, or ownership. All information provided on this permit renewal application is, to the best of my
knowledge, correct and complete.
SignatureDate: YI;2 2!
NOTARIZATION:
that
, a Notary Public for the State of
County of 'Pee',l , do hereby certify
personally appeared before me
this the day of AtfrrrSJ 20Z7 and acknowledge the due
execution of the forgoing instrument. Witness my hand and official seal,
(Notary Seal)
: :+p AjA
Notary Signature:
o'•, '�(/B co
My commission expires /L3 'Z(o 'o,Fyri_,
^ AUG 2 4 2022
Stormwater Permit Renewal Application Form Page 3 of 3 May 11, 2018
Federal Express Expansion Page 1 of 2
SWS 000630
New Hanover County
Designer's Certification
I, Phillip G. Tripp as a duly registered Professional Engineer
in the State of North Carolina, having been authorized to observe (periodically/-v"MyEfall.tirna) the
construction of the project,
Federal Express Ground
(Prof ect)
Crown Management Corporation
form
for (erly Crown ox ComoratiBon) (Project Owner) hereby state that, to the best of my
abilities, due care and diligence was used in the observation of the project construction such that the
construction was observed to be built within substantial compliance and intent of the approved plans
and specifications.
Required Items to be checked for this certification to be considered complete are on page 2 of this
form.
Noted deviations from approved plans and specifications:
Signature
Registration Number 17374
Date
llb- Mzt
SEAL
AUG 2 4 2022
BY:._
PE Certification Requirements: Page 2 of 2
1. The drainage area to the system contains approximately the permitted acreage.
2. The drainage area to the system contains no more than the permitted amount of built -
upon area.
A3. All the built -upon area associated with the project is graded such that the runoff
drains to the system.
4. The outlet/bypass structure elevations are per the approved plan.
5. The outlet structure is located per the approved plans.
6. Trash rack is provided on the outlet/bypass structure.
k7. All slopes are grassed with permanent vegetation.
e__ 8. Vegetated slopes are no steeper than 3:1.
4�_9. The inlets are located per the approved plans and do not cause short-circuiting of the
system.
10. The permitted amounts of surface area and/or volume have been provided.
ZT 1.1. Required drawdown devices are correctly sized per the approved plans.
12. All required design depths are provided.
&13. All required p arts o f the s ystem are p rovided, s uch a s a vegetated s helf, and a
forebay.
14. The overall dimensions ofthe system, as shown on the approved plans, are provided.
cc: NCDENR-DWQ
Tony Roberts, New Hanover County Building Inspections
' AUG 2 1202 " ku
Cu
BY: