Loading...
HomeMy WebLinkAboutNCG550799_Compliance Evaluation Inspection_20230530United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yrlmolday Inspection Type Inspector Fee Type 1 liu I 2 15 I 3 I NCG550799 111 12 23/05/15 117 181 r I 19 I G I 20 I 211 1 1 1 1 1 1 1 1 1 11 I 1 1 1 1_][A_]_ 1 III I I I I I l I I I I I l I I_I_I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 67 70 Li I I 71 u 72 a 73 W 74 71 I I I I I I I80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Dale Permit Effective Date POTW name and NPDES Dermit Number) ft00AM 23/05/15 21/12/17 6104 Dello Street Exit Time/Date Permit Expiration Date 6104 Dello St Durham NC 27712 11:30AM 23/05/15 25/10/31 Name(s) of Onsite Representative(s)r itles(suPhone and Fax Number(s) Other Facility Data ru Name. Address of Responsible OfficiaiM le/Phone and Fax Number Matthew Williams,6104 Dello St Durham NC 27712111 Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Sludge Handling Dispo: 0 Facility Site Review Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date James Westcott DWRIRRO WQ/919-791-4247! Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/molday Inspection Type (Cont.) NCG550799 I11 1 23/05/15 17 18 I C I Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Findings during the inspection were as follows: 1. Treatment system Operation: The wastewater treatment system shall be always maintained to prevent seepage of sewage to the surface of the ground. The system was operating as designed at the time of inspection. 2. Pumping the septic tank: You are required to inspect the septic tank at least yearly to determine if solids must be removed or if other maintenance is necessary. Septic tanks should be pumped out every five years or when the solids level is found to be more than 1/3 of the liquid depth in the septic tank compartment, whichever is greater. A pumping company can check the status periodically and determine when pumping is required. During the inspection, the permittee provided verification that the septic tank was pumped out on April 26, 2023. The General NPDES Permit requires the permittee to retain records associated with sewage disposal activities for a period of at least 5 years. 3. Chlorine tablets in the chlorinator: You are reminded that it is required that chlorine tablets be maintained in the chlorinator to ensure proper disinfection of the discharged wastewater. Chlorine tablets provide effective disinfection and prevent/limit harmful bacteria from discharging to the environment. The product label for these tablets must indicate the tablets are approved for wastewater use and not for swimming pools. Part 1, Section D (1) of General NPDES Permit NCG550000 requires the permittee to inspect the tablet chlorinator weekly to ensure there is an adequate supply of tablets for continuous and proper operation. Section D (4) requires the permittee to maintain all system components, always including ...disinfection units... and in good operating order. The correct chlorine tablets in the chlorinator at the time of inspection. Please continue to ensure the correct type of tablets are used and maintained in the chlorinator as required by the General NPDES Permit. 4. Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements, within General Permit NCG550000 requires a permittee to sample and analyze the effluent leaving his/her treatment system prior to discharge annually. Parameters to be sampled and analyzed include Flow, BOD (Biochemical Oxygen Demand), Total Suspended Solids, Fecal Coliform and Total Residual Chlorine. At the time of inspection, a receipt of the required annual effluent analysis was not provided. Please collect a representative sample of the effluent, have it analyzed by a certified commercial laboratory and submit the results to this office no later than August 1, 2023 and submit the results to this office within 3 weeks after sampling results are received. If, during this time, you are unable to collect a representative sample of the effluent discharge due to insufficient flow from the discharge pipe, then update this office with that information and continue to monitor the discharge and if conditions for sampling become favorable, then arrange to collect a sample. Failure to monitor the effluent discharge as required is a violation of NPDES General Permit NCG550000. 5. Discharge outlet location. The permittee is required to conduct a visual review of the outfall location at least twice each year (one at the time of sampling) to ensure that no visible solids or other obvious evidence of system malfunctioning is observed. Any visible signs of a malfunctioning system shall be documented, and steps taken to correct the problem. The discharge pipe was clear of obstruction and well maintained on the day of the inspection. Please ensure the outlet is always visible/maintained and cleared of vegetation, soil, and leaves. Page# 2 Permit: NCG550799 Owner - Facility: 6104 Dello Street Inspection Date: 05/15/2023 Inspection Type: Compliance Evaluation Yes No NA NE Page#