HomeMy WebLinkAbout040033_routine_20230605Division of Water Resources. ,
Facility'Number Division of Soil and Water Conservation
O Other Agency����
type of Visit: 1PCompliance Inspection O Operation Review O Structure Evaluation O Technical Assistance
Rteason for Visit: I? Routine O Complaint O Follow-up O Referral O Emergency O Other O Denied Access
Date of Visit: (p , & 24 Arrival Time: Departure Time: � County: a, cjo
Farm Name: --ruv n CKS FA r rJ 1 Owner Email:
Owner Name: �,ioa1 fi� Ro W, famrl Phone:
Mailing Address:
Physical Address:
Facility Contact: Nmd 1 ) � �j� Title:
Onsite Representative:
Certified Operator: Jt om N V
Back-up Operator:
Location of Farm:
Design Current
Swine Capacity Pop.
Wean to Finish
Wean to Feeder
Feeder to Finish
Farrow to Wean
Farrow to Feeder
Farrow to Finish
Gilts
Boars
Other
Latitude:
Region:_
Phone:
Integrator: Grni ffi f l'A
Certification Number: 911015
Certification Number:
Design Current
Wet Poultry Capacity Pop.
Layer
Non -Layer
Design Current
Dry Poultry C'.anacity ,. Pon.
Layers
Non -Layers
Pullets
Turkeys
Turkey Pouets
Other
Dischar1jes and Stream Impacts
1. Is any discharge observed from any part of the operation?
Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: _
a. Was the conveyance man-made?
b. Did the discharge reach waters of the State? (If yes, notify DWR)
c. What is the estimated volume that reached waters of the State (gallons)? _
d. Does the discharge bypass the waste management system? (If yes, notify DWR)
2. Is there evidence of a past discharge from any part of the operation?
3. Were there any observable adverse impacts or potential adverse impacts to the waters
of the State other than from a discharge?
Longitude:
Design Current
Cattle a Capacity s Pop.-'-'
Dairy Cow
Dairy Calf
Dairy Heifer
Dry Cow
Non -Dairy
Beef Stocker
Beef Feeder
Beef Brood Cow
❑ Yes No
❑ Yes No
❑ Yes No
❑ Yes X
No
❑ Yes No
❑ Yes E No
❑NA ❑NE
❑ NA ❑ NE
❑NA ❑NE
❑ NA ❑ NE
❑NA ❑NE
❑ NA ❑ NE
Page I of 3 511212020 Continued
Facility Number:` - �j�j Date of Inspection:
Waste Collection & Treatment
4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? ❑ Yes �] No
a. If yes, is waste level into the structural freeboard? ❑ Yes No
Structure 1
Identifier:
Spillway?:
Designed Freeboard (in):
Observed Freeboard (in):
Structure 2 Structure 3 Structure 4
5. Are there any immediate threats to the integrity of any of the structures observed?
(i.e., large trees, severe erosion, seepage, etc.)
6. Are there structures on -site which are not properly addressed and/or managed through a
waste management or closure plan?
❑ NA ❑ NE
❑ NA ❑ NE
Structure 5 Structure 6
❑ Yes No ❑ NA ❑ NE
❑ Yes No ❑ NA ❑ NE
If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental threat, notify DWR
7. Do any of the structures need maintenance or improvement?
❑ Yes No
❑ NA
❑ NE
8. Do any of the structures lack adequate markers as required by the permit?
❑ Yes No
❑ NA
❑ NE
(not applicable to roofed pits, dry stacks, and/or wet stacks)
9. Does any part of the waste management system other than the waste structures require
❑ Yes No
❑ NA
❑ NE
maintenance or improvement?
Waste Application
10. Are there any required buffers, setbacks, or compliance alternatives that need
❑ Yes No
❑ NA
❑ NE
maintenance or improvement?
11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Yes t No ❑ NA ❑ NE
❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.)
❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil
❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑Applicatiion Outside of Approved Area
12. Crop Type(s): co `� urn, Got inaycV, f-ayQ i �bibeere
13. Soil Type(s): C l��CK�l f "a tl�Magd l/ �►
14. Do the receiving crops differ from those designated in the CAWMP? ❑ Yes No ❑ NA ❑ NE
15. Does the receiving crop and/or land application site need improvement? ❑ Yes No ❑ NA ❑ NE
16. Did the facility fail to secure and/or operate per the irrigation design or wettable ❑ Yes No ❑ NA ❑ NE
acres determination?
17. Does the facility lack adequate acreage for land application? ❑ Yes No ❑ NA ❑ NE
18. Is there a lack of properly operating waste application equipment? ❑ Yes No ❑ NA ❑ NE
Required Records & Documents
19. Did the facility fail to have the Certificate of Coverage & Permit readily available? [—]Yes No ❑ NA ❑ NE
20. Does the facility fail to have all components of the CAWMP readily available? If yes, check ❑ Yes o ❑ NA ❑ NE
the appropriate box.
❑ WUP ❑ Checklists ❑ Design ❑ Maps ❑ Lease Agreements ❑ Other:
21. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Yes No ❑ NA ❑ NE
❑ Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Waste Trans ers ❑ Weather Code
❑ Rainfall ❑ Stocking ❑ Crop Yield ❑ 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey
22. Did the facility fail to install and maintain a rain gauge? ❑ Yes No ❑ NA ❑ NE
23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes �] No ❑ NA ❑ NE
Page 2 of 3 511212020 Continued
Facility Number: - 'If -A Date of Inspection:
24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ Yes No ❑ NA ❑ NE
25. Is the facility out of compliance with permit conditions related to sludge? If yes, check ❑ Yes �No ❑ NA ❑ NE
the appropriate box(es) below.
❑ Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels
❑ Non -compliant sludge levels in any lagoon
List structure(s) and date of first survey indicating non-compliance:
26. Did the facility fail to provide documentation of an actively certified operator in charge? ❑ Yes MNo ❑ NA ❑ NE
27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? ❑ Yes No ❑ NA ❑ NE
Other Issues
28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document
and report mortality rates that were higher than normal?
29. At the time of the inspection did the facility pose an odor or air quality concern?
If yes, contact a regional Air Quality representative immediately.
30. Did the facility fail to notify the Regional Office of emergency situations as required by the
permit? (i.e., discharge, freeboard problems, over -application)
31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below.
❑ Application Field ❑ Lagoon/Storage Pond ❑ Other:
32. Were any additional problems noted which cause non-compliance of the permit or CAWMP?
33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative?
34. Does the facility require a follow-up visit by the same agency?
❑ Yes \ o ❑ NA ❑ NE
❑ Yes NNo ❑ NA ❑ NE
❑ Yes �qNo ❑ NA ❑ NE
❑ Yes NNo ❑ NA ❑ NE
❑ Yes
No
❑ NA
❑ NE
❑ Yes
No
❑ NA
❑ NE
[:]Yes
No
❑ NA
❑ NE
Comments (refer to question #): Explain any YES answers and/or any additional recommendations or any other comments. °
Use drawings offacility -to better explain situations (use additional pages i as necessary). s <
vpdcaed in NnvZX
Reviewer/Inspector Name:
Reviewer/Inspector Signature:
Page 3 of 3
jQCat d
Frp'ebb d
Grog �_l d S V
cAudg-e I.11- zz
ca i; p/1 0-11-I 'M rnarM 2'-j1
-zoi,
1y7�
�oz
Sc�i I.2�7.22
Phone: qiq.M qjj_,�
Date: (p ' F2- ��
511212020