Loading...
HomeMy WebLinkAboutNCG190104_2022 DMR_20221129NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG190000 Marinas and Shipbuilding Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appr npriate DEMLR Regional Office. Certificate of Coverage No. NCG19 0104 Person Collecting Samples: Kevin Gagnon Facility Name: Stevens Towing Laboratory Name: Environmental chemists, Inc. Facility County: chowan Laboratory Cert. No.: 20-46107 Discharge during this period: 0 Yes 0 No (if no, skip to signature and dote) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? LjYes No If so, which Tier (I, II, or Ill)? A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gc)v/Forms/SW-DMR Yes Q No Date Uploaded: 11117,2022 Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall3 Outfall Outfall Outfall Outfall Code N/A Receiving Stream Class B, NSW N/A Date Sample Collected MM/DD/YYYY date 46529 24-Hour Rainfall in incises 0.25 C0530 TSS in mg/L (100 or SO*) Estimated New Motor/Hydraulic Oil NCOIL usage in gal/month 0 00340 Chemical Oxygen Demand in mg/L (120) 105 pH in standard units 16.0 — 9.0 FW, 6.8 — 00400 8.5 SW) Aluminum, total recoverable in mg/ L 01105 (0.75 FW, 0.24 SW) 1.97 Copper, total recoverable in mg/L 01119 (0.010 FW, 0.006 SV4 289 Lead, total recoverable (as Pb) in mg/ L D1051 10.075 FW, 0.22 SW) 012 Zinc, total recoverable in mg/L (0.126 01D94 FW, 0.095 SW) 347 Additional parameters for outfalls in drainage areas that use >55 gallons per month of new hydraulic oil on average 00552 Non -Polar Oil St Grease in mg/L (15) <5.0 *Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/iL FW (Freshwater) SW (Saltwater) Notes (optional): "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." �" 11/1512022 Signature of Permittee or Delegated Authorized Individual Date brubino@q%&ibte.cam 252-491.8147 Email Address Phone Number