Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW8180705_Historical File_20181025
Drainage Calculations for Lot 45-A J H Batts Division Owner: A `N' A Builders, Inc. 13480 NC Highway 50 Surf City, NC 28445 Engineer: Stroud Engineering, P.A. 102 D Cinema Drive Wilmington, NC 27858 ECEIVEr _ OCT 02 2018 MAL° r + ° 1"77 • - BY: David L. Menius, P.E. 2� 'Zp1jd' Date NCDEQ Stormwater Design Calculations Wet Pond Pmyect: Lot 45-A JH Batts Division Job#: PW 1335 Engineer: DLM Date: 6/6/2016 Rational Method (See accompanying figures and tables as noted) Predevelopment Land Use Description C Area ac Total area 2.10 Impervious 0.95 0.00 Pervious 0.2 2.10 Weighted C: 0.20 Impervious (ex`, 0.0% Postdevelopment Land Use Description C AreaJac) Total area 2.10 Impervious 0.95 1.11 Pervious 0.2 0.99206 Weighted C: , 0.60 Impervious (prop) 62.69% Curve Number Drainage Area (ac): Net Impervious Area (so): % Impervious: Curve Number (CN):* Predevelopment Postdevelo ment 2.10 2.10 0.00 1.11 0.00 52.69 60 70 0 drainage area input total area 91350 at sidewalks 0 sf roads 0 sf buildings 0 sf other 0 sf total ex SUA 0 sf drainage area input total area 91350 sf sidewalks 271.7 sf parking 30769 sf building 9900 sf other 0 sf reserve 4750 sf total prop BUR 48136 sf `where CN„. is type B soils and CNpost is a weighted average of impervious and lawn (good condition, We A soils) Runoff Q Fre uency year 1 Rainfall, P aka Rd 24 hour)* 3.75 Pre -Runoff, Q (in)— 0.64 E2.68 PosL-Runoff, Q 0- 1.17 Intensity, 1(24 hour)* 0.166 Pre Development Peak runoff from 1 year 24 hour storm = C * I * A = Pre Development Peak runoff from 10 year 24 hour storm = C * I * A = Post Development Peak runoff from 1 year 24 hour storm (w/o detention) = C * 1 * A = Post Development peak runoff from 10 year 24 hour storm (wlo detention) = C * I * A = *Rainfall data per NOAAAtlas 14 -where Q = ((P - 0.2S)s I (P + 0.8S) and S = (10001 CN) - 10 0.07 US 0.12 GFS 0.19 CFS 0.37 CFS ,,b DEQ 1 yr 24 hr Pre/Post Method Pre R,= 0.05 4 0.9 • Impervious Ratio Rv = 0.050 Post R, = 0.05 s 0.9. Impervious Ratio Rv = 0.524 Control Volume -3630-Rd`R,.•A where Rd = 3.75 Predevelonmentrunofl= 1427 cf Postdevelopmentrunoff= 14966 cf Water Quality Required Storage= 13538 cf Schuler's Simple Method CONTROLS R, = 0.05 4 0.9 . Impervious Ratio Rv , 0.524 Control Volume = 3630' Rd ` R,' A where Rd = 1.5 in. Water Quality Required Storage= 5986 cf NA USE: i3538 CF FOR POND DESIGN Basin Dimensions Rnlnw Parrnanenl P-1 a SA Forebay Inc. Volume Forebay Total Volume Forebay SA Pond Inc. Volume Main Pond Total Volume Main Pond -9.0 0 0 0 0 0 0 -8.0 0 0 0 0 0 0 -7.0 0 0 0 0 0 0 -6.0 0 0 0 0 0 0 -5.01 0 0 01 0 -4.0 0 -- —o _ 0 0 0 0 -3.0 0 0 0 0 0 0 -2.0 12 0 0 910 0 0 -1.0 103 58 58 1333 1122 1122 0.0 258 181 238 1781 1557 2679 1.0 412 3351 573 2254 2018 4696 2.01 591 502 1076 27541 2504 7200 3.0 1213 9021 1977 43481 35511 10751 % Forebay= 18.4% % Is 15% - 20%, OK :-Pond Bottom El ~Sediment Removal El 'Permanent Pool El State Reauired Denth/Surface Area Calculation V,,p (main pnrd)- Amr, .,: _, (main pond)= Shelf Widtt: Pedmeterp, ,,, ,,,,a(main pcnd)= DaveRCe' Desired TSS Remove: Caoadiy= Enter Table 2 SAIDA lower depth interval: Impe!vio.:s Cover = Enter Table 2 SAIDA lower%6UA interval: Enter Table 2 SAIDA values for depth and %SUA: Calculated SAIDA= Required Surface Area= Aa:,„, -j,,„!(main pond;= A!,,..,e ne.-- o..,a 5.35 3083 sf 4348 of El. Stage SA Inc Vol. Pond Total Vol. -bond 3.0 0.0 6561 0 0 3.5 0.5 6154 2929 2929 4.0 1.0 6766 3230 6159 4.6 1.5 7397 3541 9700 5.0 2.0 80471 3861 13551 5.5 2.5 8716 4191 17751 6.0 3.0 9404 4530 22281 is > 30, OK •(submerged shelf) Is > required SA, OK State Stage= State El.= Tap El.=Freeboard-- a ft is - 1.0', OK [Aft 2-5 Day Drawdown for State Volume Max (2 Day) Flow- 0.08 ds Min (6 Day) Flow-- 0.03 ds Slot Stage= 2.00 ft Avo Head= I 0.67 1t 2 Day Area= 0,020 sf 6 Day Area= 0.008 sf 2 Day Diameter- 1.913 In 5 Day Diameter- I 1.210 in Provide Orifice= 1.50 In Drawdown Flow-- 0.06 Ole Is < predevelopment discharge from 1 year 24 hour storm, OK Drawdown Time= 3.3 days is within 2.5 days. OK Jhours 3 § § § § j iu- N � , � _ _ 2, �, , . � ) { 2 LU LU 0 § < / ) Sa �LU § ƒn ) ( 2 6 d o o § BK(f([EE f R k§m } /( �u § i Pi § / § 3 § CY/ f) -N § § 0 5 2 20 2§ # \ — 2 § e op 03 (( CII ` A / § ` 00 6 / » co co §) 2 } , R (Vi j in �} $ LLI & � \« \§ ;e B o # £k\A z POND/SEDIMENT BASIN EMERGENCY OUTFALL CALCULATIONS Prajed E OT 45-A J-! BAITS DI413ION Jcb R PP: ;335 Engineer. D LM . Date: 61, 4:2016 NOTE: T,; ;30 MIN (-OST DETENTION) POND _ OUTPUT iNPL" ? OUTPUT j DESIGN _ -INPUT DRAINAGE RUNOFF ; LONGI UO:NA'- SIDESWPE BOTTOM RIPRAP FLOW FLOVJTOP FLOW STORM AREA (AC) C RATE 'CFS) SLOPE FT/F,) HN W JTH (FT) n VALUE DEPTH (FT) WIDTH (FT; VELOCITY 1 I 1.52 2.77 0.7 2.95 0.200 3 10.0 0.04 0.09 10.5 3.25 10 1.52 4.58 0.7 ( 4.87 i 0.200 3 '.O.0 0.04 0.12 10.7 3.94 50 1.52 6.82 0.7 I 6.19 0.200 3 10.0 0.04 0.14 10.9 4.32 ;03 1.52 6.37 0.7 I 6.78 I 0.200 3 10.0 0.04 GA5 10.9 4.47 TEMPORARY DIVERSION SWALE CALCULATIONS ESTMATED TIME OF CONCENTRATON = 10 MIN RESULTING 2 YEAR STORM INTENSITY = 5.72 iN/HR CONSTRUCTION PHASE"C"= 0.3 INPUT OUTPUT I INPUT I OUTPUT SWALE DRAINAGE RUNOFF I LONGITUDINAL SIDE SLOPE BOTTOM MANNING I FLOW FLOW TOP FLOW NUMBER AREA AC I C RATE (CFS) SLOPE FT/FT' HN WIDTH FT nVALUE DEPTH (FT) WIDTH P VELOCITY 1 0.4 5.72 0.3 0.63 0.002 3 1.0 0.025 0.33 3.0 0.95 5 0.9 5.72 0.3 1.49 0,002 3 1.0 0.025 0.50 4o 1.20 FOREBAY WEIR OVERFLOW CALCULATIONS INPUT OUTPUT I INPUT I OUTPUT POND NUMBER DRAINAGE 10 YR AREA (AC) I C RUNOFF (LONGITUDINAL SIDE SLOPE BOTTOM RIPRAP RATE CFS SLOPE(FT/FT) HN WIDTH FT nVALUE FLOW FLOW TOP FLOW I DEPTH (FTQ WIDTH F VELOCITY 1 1.2 5.72 0.3 2.13 1.000 3 25.0 0.04 0.03 25.2 3.26 SEDIMENT BASIN CALCULATIONS BASIN ;f 1 DISTURBANCE AREA= 2.10 AC DRAINAGE AREA-- 2.10 AC ESTMATED TIME OF CONCENTRATON = 30 MIN RESULTING 10 YEAR STORM INTENSITY = 4.68 IN/HR CONSTRUCTION PHASE "C" = 0.3 Q=CfA= 2.89 CFS SURFACE AREA =325'Q= 938 SF STORAGE = 1800CF PER AC DISTURBED = 3760 OF APPROX LENGTH 175 FT APPROX WIDTH 45 FT PROVIDE ACTIVE DEPTH 2.00 FT SURFACEAREA= 7875»REQUIRED. OK VOLUME PROVIDED = 14870 » REQUIRED, OK 3 DAY DEWATERING FLOW RATE 4957 CF/OAY PROPOSED ORIFICE DIAMETER 1.6 IN RESULTING AREAA=3.14/4' DA2= 1.76626 SQ IN 0.012265625 SQ FT DRIVING HEAD TO CENTROID OF ORIFICE 0.67 FT STORAGE VOLUME DRAWDOWN RATE PER THE ORIFICE EQUATION Q=Cd'A"(2' G " h)A.5 0.05 CFS 4164 OF PER DAY STORAGE VOLUME DRAWDOWN TIME 3.6 DAYS ORIFICE EQUATION NOTE: SKIMMER DRAWDOWN RATE CALCULATED PER THE ORIFICE EQUATION Q=Cd'A'(2'g'h)A.5 WHERE: A = PROPOSED ORIFICE AREA= VARIES (SQ FT) Cd = DISCHARGE COEFFICIENT = 0.6 (UNITLESS) g = GRAVITATIONAL ACCELERATON = 32.2 FTISA2 h = DRIVING HEAD (0.33 X ACTIVE DEPTH) = VARIES (FT) Q = POND OUTFLOW = VARIES (CFS) DISSIPATOR SIZING ZONE 2 CLASS B APRON MATERIAL LENGTH = 6 X DIAMETER WIDTH = 3 X DIAMETER PIPE APRON APRON DIAMETER LENGTH WIDTH 12 6.00 3.00 15 7.50 3.75 16 9.00 4.50 24 12.00 6.00 30 15.G0 7.50 36 18.00 9.00 /Jb7a5-0 Pusey, Steven From: Luke Menius <Imenius@stroudengineer.com> Sent: Tuesday, October 02, 2018 12:28 PM To: Pusey, Steven Subject: [External] Fwd: Lot 45-A JH Batts Subdivision; SW8 180705 RFAI Attachments: SUPPLEMENT revised.pdf, CALCULATIONS revised.pdf iCAUTION. :. i.; - RP a • • • • Report Spam. From: Luke Menius Sent: Tuesday, September 25, 2018 4:11:33 PM To: Pusey, Steven Subject: FW: Lot 45-AJH Batts Subdivision; SW8 180705 RFAI I just realized the attachment names were reversed. Also, when I updated the spreadsheet to use only the surface area of the main pond for the permanent pool, it created an error in the temporary pool areas/volumes. Please use the attached PDFs and disregard the previous ones. Again, no changes to the plans were necessary. Let me know if you want hardcopies of these documents. David L. Menius, P.E. Stroud Engineering, P. A. 102-D Cinema Drive Wilmington, NC 28403 910-815-0775 ext 225 From: Luke Menius Sent: Tuesday, September 25, 2018 1:05 PM ECEp ' To: 'Pusey, Steven' <steven.pusey@ncdenr.gov> ��A Cc:'Mo Afify' <meafify@gmail.com> OCT 0 x Subject: RE: Lot 45-A JH Batts Subdivision; SW8 180705 RFAI 9 ft Steve, Please find the attached PDFs of the requested additional information and revisions. These revisions did not affect the plans. If desired, I can deliver hardcopies once the Cardinal Drive office reopens. I've attempted to address your concerns as follows: The property area is 2.10 acres. There are no surface waters or coastal wetlands; so the total project area is 2.10 acres as well. This is reported correctly on the SWU-101. The requested PDF of the revised supplement form is attached. The SCM is designed to treat the difference in runoff between the pre and post development 1 year 24 hour storm. The calculations and pond sizing were correct. I've corrected the supplement to report the 3.75" 1 year, 24 hour storm precipitation. Note that the DEQ spreadsheet rounds this value to 3.8. • Inlet and outlet erosion are controlled by properly sized riprap aprons. Calculations are included. Note that the inlet pipe is submerged, which serves to reduces scour adjacent to the FES. Also note that the headwater/tailwater conditions on the calculations were incorrect. The revised calculations confirm the 10 year flow velocity in the 24" outfall pipe is < 3 FPS. • The SA/DA method is used. I've revised the calculations to report only the main pool SA. • The SA/DA ratio is interpolated for both depth and percent impervious. Linear interpolation is used. • The SA/DA table values have been corrected and the new table has now been used. • The average depth is between 3-8 feet. The average depth calculation excludes the submerged shelf. Equation 3 was used. • The forebay volume is 15-20 percent of the main pool volume. I've reviewed the percent forebay calculations and found them to be correct. • The forebay volume and depths in the supplement have been revised. • The forebay weir is lined with riprap to prevent erosion. Overflow calculations are provided. David L. Menius, P.E. Stroud Engineering, P. A. 102-D Cinema Drive Wilmington, NC 28403 910-815-0775 ext 225 From: Pusey, Steven <steven.p-t.!sey@icdenr.gov> Sent: Wednesday, September 12, 2018 4:16 PM To: Luke Menius <lm. nius@4trcudenQineer.com> Subject: Lot 45-A JH Batts Subdivision; SW8 180705 RFAI Luke, Please reference the attached Request for Additional Information (RFAI) on permit application SW8 180705. Regards, Steve Puseu Steve Pusey, Ell Environmental Engineer 11 Division of Energy, Mineral and Land Resources — State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7334 direct steven.pusey(a ncdenr.gov 127 Cardinal Drive Ext. Wilmington, NC 28405 E-i170i1 CO!"rB '%Cl Ce?C:^.o i ? ?f?_1 r:+ ri e') -s" i.' <:.' t `;, :> > hi 10 2'00- C'L'roll!-a L17' ! a.7': iT t' i! .. : _ r t0 iJIV j:'aet . S. 2 Pusey, Sven From: Pusey, Steven Sent: Wednesday, September 12, 2018 4:18 PM To: 'Mo Afify' Subject: FW. Lot AS -A JH Batts Subdivision; SW8 180705 RFAI Attachments: 2018 09 addinfo 180705.pdf FYI, &re '�, DEQ-DEMLR Stormwater From: Pusey, Steven Sent: Wednesday, September 12, 2018 4:16 PM To: Luke Menius <Imenius@stroudengineer.com> Subject: Lot 45-A JH Batts Subdivision; SW8180705 RFAI Luke, Please reference the attached Request for Additional Information (RFAI) on permit application SW8180705. Regards, Steve PvLed Steve Pusey, El Environmental Engineer II Division of Energy, Mineral and Land Resources — State Stomiwater Program Department of Environmental Quality 910 796 7215 office 910 796 7334 direct steven. Dusev(-ncden r.aov 127 Cardinal Drive Ext. Wilmington, NC 28405 ,�na�ia Omw. i+m�rpxw{wrw, pl7witrz Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. IMP Before printing this email, please consider your budget and the environment. ROY COOPER NORTH CAROLINA Governor Environmental Quality MICHAEL S. REGAN Secretary WILLIAM E. (TOBY) VINSON, JR Interim Director September 12, 2018 A'N' A Builders, Inc. Attn: Mohamad Afify, Secretary 13480 NC Hwy 50 Surf City, NC 28445 Email: meafify@gmail.com Subject: Request for Additional Information Stormwater Project No. SW8180705 Lot 45-A JH Batts Division Pender County Dear Mr. Afify: The Wilmington Regional Office received and accepted a State Stormwater Management Permit Application for the subject project on July 5, 2018. A preliminary in-depth review of that information has determined that the application is not complete and that additional information is needed. To continue the review, please provide the following additional information: Project / Application Requirements and Permitting Process: 1. 15A NCAC 02H.1003(1)(c): Please exclude surface waters and coastal wetlands measured landward from the normal high waterline from the total drainage area presented in Section IV.10 of the application. The total drainage area presented in Section IV.10 should be consistent with the total project area presented in Section IV.7 of the application. 2. 15A NCAC 02H.1042(2): Please email the supplement form to the email address provided below so that it can be preserved electronically per the regulatory requirements. Requirements for SCMs 15A NCAC 02H.1019(6): a. For SA waters, SCMs must be designed to store, control and treat the stormwater runoff from all surfaces generated by the difference between pre and post development 1-yr, 24- hour storm. The rainfall depth shown in the calculations is 3.75 inches, however the design depth shown on the Supplement is 1.5". Please revise and resubmit this document. General MDCs: 15A NCAC 02H.1050(4): a. Please provide engineering calculations demonstrating that the inlets of the SCMs shall be designed to protect the SCM from erosion resulting from stormwater flow into the SCM during the peak flow from the 10-year storm event. b. Please provide engineering calculations demonstrating that the outlets of the SCM will not cause erosion downslope of the discharge point during the peak flow from the 10-year storm event. z. - o �--R RLI PEQ� �9Mmm .- prtld� North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources Wilmington Regional Office 1 127 Cardinal Drive Extension I Wilmington, North Carolina 28405 910.796.7215 State Stormwater Permit No. SW8180705 Page 2 of 3 General MDCs: (cont'd.) The discharge velocity from 10-yr storm calculations shows that the velocity to the "OS" outlet structure to FES 2 is 8.42 ft/s. How is this dissipated? Wet Detention Pond MDCs: 2. 15A NCAC 02H.1053(1): a. Please confirm that the chosen sizing method (SA/DA or HRT) is being used to only size the main pool surface area and volume and does not include the forebay. The surface area presented and compared against the minimum required surface area is for the entire pond, including the forebay. b. When determining the appropriate SA/DA ratio and the percent of impervious area is in between the options available, the next larger percent may be selected or the ratio at the proposed percent of impervious area can be determined by interpolation. c. Please provide documentation and/or calculations to support the identified SA/DA ratio and the associated required surface area for the permanent pool. The project has been designed with a percent of impervious area of 52.7% and the pond is shown to have an average depth of 3.5 ft in the calculations; however, the selected SA/DA ratio is associated with a percent of impervious area of 70% and an average depth of 3.0 ft. Please refer to Table 2 in Chapter C-3 of the Stormwater Design Manual, which was last revised on April 18, 2017. d. The SA/DA ratios used in the calculations are not consistent with the ratios provided in Table 2 of Chapter C-3 of the Stormwater Design Manual, which was last revised on April 18, 2017. Please confirm that the latest design criteria are being used. 3. 15A NCAC 02H.1053(2): a. The average depth of the main pool shall be 3-8 feet below the permanent pool elevation. b. If it desired to exclude the submerged potion of the vegetated shelf from the average depth calculation, Equation 3 on page 8 in Chapter C-3 should be used. Alternative calculations may be presented for consideration as a variation per .1003(6). 4. 15A NCAC 02H.1053(5)(a): a. Forebay volume shall be 15 to 20 percent of the volume in the main pool. b. The calculations based the percent of forebay volume provided against the total permanent pool volume provided (main pool and forebay). Please compare the forebay volume against the main pool volume only. c. Please demonstrate that the forebays have been sized appropriately for their respective contributing drainage areas. d. and 15A NCAC 02H.1003(6): The supplement and calculations indicate that the forebay will exceed 20% of the main pool volume. Please provide technical justification in accordance with the reference rule to demonstrate that the proposed design will provide equal or better stormwater control and equal or better protection of waters of the State than the requirements of the MDC and that it will function in perpetuity. Please include an abbreviated version of this justification in the additional information section of the supplement. 5. 15A NCAC 02H.1053(5)(c): Please demonstrate that the water flowing over or through the structure that separates the forebay from the main pool shall flow at a nonerosive velocity. State Stormwater Permit No. SW8180705 Page 3 of 3 Please remember to confirm that any revised information is presented consistently throughout the application documents including calculations, supplements, narrative, and plans. Please also remember to provide two hard copies of any updated documents per 15A NCAC 02H.1042(2). The requested information should be received in this Office prior to October 3, 2018, or the application will be returned as incomplete. If the project is returned and you wish to re -submit later, you will need to resubmit all required items at that time, including the application fee. If additional time is needed to submit the requested information please e-mail, mail, or fax your extension request, prior to the original due date, to the Division using the contact information available in this letter. The extension request must include a justification and a date of when the requested information will be submitted to the Division. Please remember that extension requests delay the issuance of the final permit. The Division is allowed 90 days from the receipt of a complete application to issue the permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. Please reference the State assigned application number on all correspondence. If you have any questions concerning this matter, please feel free to call me at (910) 796-7215 or email me at steven.pusey@ncdenr.gov. Sincerely, s q. ;V Steven G. Pusey, El Environmental Engineer II GDS/sgp: \\\Stormwater\Permits & Projects\2018\180705 HD\2018 09 addinfo 180705 cc: Luke Menius PE; via email Wilmington kegional Office Stormwater File Pussy, Steven From: Pusey, Steven Sent: Monday, July 16, 2018 2:38 PM To: 'Mo Afify' Subject FW. Lot 45-A JFI Batts division; SW8180705 Sorry, I got your email address wrong the first time. Here's a forwarded copy of the acknowledgment. Regards, ASS V� From: Pusey, Steven Sent: Monday, July 16, 2018 2:36 PM To:'meadidy@gmail.com' <meadidy@gmail.com>; Luke Menius <Imenius@stroudengineer.com> Subject: Lot 45-A J H Batts Division; SW8180705 Gentlemen: The Wilmington Regional Office of the Division of Energy, Mineral, and Land Resources (Stormwater Section) accepted the Stormwater Permit Application for a new project on July 5, 2018. The project has been assigned to Steve Pusey and you will be notified if additional information is needed. Please be advised that the construction of built -upon area may not commence until the Stormwater Permit is issued. Thank you. Steve Pusey, El Environmental Engineer II Division of Energy, Mineral and Land Resources — State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7334 direct steven. r)usey0,ncdenr.Qov 127 Cardinal Drive ExL Wilmington, NC 28405 aria sMnrspenrsa. ru 9nwua * x Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Before printing this email, please consider your budget and the environment. Application Completeness Review Checklist Project Name: 1.0 �- �j [� �jf� 1 r 5 r Date Delivered to WIRO BIMS Received/Accepted Date: Project Couni:y/Location: ��Z� *BIMS Acknowledged Date: IRule(s): Ti017 Coastal ®2008 Coastal ®1995 Coastal ®Phase II ®Universal ®1988 Coastal Permit Action New>r Major Mod / Minor Mod / Renewal / Transfer '+ , '`New Permit #: Permit Type• HU LD / LD Overall / HD &LD Combo General Permi / Offsite / Exemp�t-7/ Rescission SCM Type(s):floc_ Development Type: ommerci / Residential % Other Subdivided?: Subdivision or Simile Lot For New or Transferred Permits Permittee is: Property Owner(s) ❑Developer Lessee Purchaser �tiOA. Paperwork Emailed Engineer on - Existing Permit #: ❑PE Cert on File? Offsite to SW8: �uppiement(s (1, originai per BMP) ZfZ &M with correct/,original signatures (1 original per BMP except LSJVFS and swaies) application with correct/original signatures �f,-�► EE Forp or LLC: Sig. Auth. per SoS or Si natu uthorization letlet er r report $505 [within 6mo) Check#(s): i DC, 3) No Fee '❑Sol#s Report: w/SHWT or General Report culations (signed/sealed) ❑Deed Restrictions, if subdivided: "Signed & Notarized Template Correct Template Comm Res & HD LD or Recorded Covenants Master PE Cert on File? Stream Class: _ I! SA Map E]ORW Map mail Address: Design Engineer mail Address: Property Owner eed Email Address: Lessee Lease Agreement Email Address: Purchaser Purchase Agreement Email Address: Developer Email Address: HOA Representative Recorded Plats F150% or more Lots Sold List c• roject Narrative 015GS Map Plans El`-ts OWet#ands: Delineated or No Wetlands e c-r icinity Map [�roject Boundaries Legend ElL3yout (proposed BUA dimensions) MDA Maus retails (roads, cul-de-sacs, curbs, sidewalks, BMPs, Buildings, etc) Existing Conditions Landscape Plan Grading Seal REVIEWER NAME: NOTES TO REVIEWER: *Enter BIMS Acknowledged Date on this Sheet **FOR NEW Projects -Enter New Permit # on Supplements & Deed Restiction Templates. ,Checklists\Comp!eteness Review Cnecklist_2018 03 13 STROUD ENGINEERING, P.A. 102-D Cinema Drive Wilmington, NC 28403 [LIEVV EQ @IF U ° I nMA 044Lad Em (910) 815.0775 TO / C_ P'C cQ WE ARE SENDING YOU ❑ Attached ❑ Under separate cover via ❑ Shop drawings ❑ Prints ❑ Plans ❑ Copy of letter ❑ Change order ❑ DATE JOB NO. jam / �� � 33 ATTENTI N the following items: ❑ Samples ❑ Specifications COPIES DATE NO. DESCRIPTION a>_ l u ..I Oki if fin r4p l THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ For your use ❑ As requested ❑ For review and comment ❑ FORBIDS DUE REMARKS ❑ Approved as submitted ❑ Approved as noted ❑ Returned for corrections ❑ Resubmit copies for approval ❑ Submit copies for distribution ❑ Return corrected prints ❑ PRINTS RETURNED AFTER LOAN TO US v COPY TO ` SP NED: If enclosures are not as noised, kindly notify us at once. Drainage Calculations for Lot 45-A JH Batts Division Owner: A `N' A Builders, Inc. 13480 NC Highway 50 Surf City, NC 28445 Engineer: Stroud Engineering, P.A. 102 D Cinema Drive Wilmington, NC 27858 `\\\111411I1!/�j� •a SEAL - 35677 - David L. Menius, P.E. Iy/-ZP 18 Date ECEIV E� JUL 0 5 2016 NCDEQ Stormwater Design Calculations Wet Pond Project: Lot 45-A JH Batts Division Job #: PW 1,,335 Engineer. DLM Date: 6/6/2018 Rational Method (See accompanying figures and tables as noted) Predevelopment Land Use Description C Area ac Total area 2.10 Impervious 0.95 0.00 Pervious 0.2 2.10 Weighted C: 0.20 Impervious (ex) 0.0% Postdevelopment Land Use drainage area input total area 91350 sf sidewalks 0 sf roads 0 sf buildings 0 sf other 0 sf total ex BUA 0 sf Description C Area ac drainage area input Total area 2.10 total area 91350 sf Impervious 0.95 1.11 sidewalks 2717 sf Pervious 0.2 0.99206 parking 30769 sf building 9900 sf Weighted C: 0.50 other 0 sf Impervious (prop) 52.69% reserve 4750 sf total prop BUA 48136 sf Curve Number Predevelo ment Postdevelo ment Drainage Area (ac): 2.10 2.10 Net Impervious Area (ac): 0.00 1.11 % Impervious: 0.00 52.69 Curve Number (CN):* 60 70 'where CN_ is type B soils and CNpost is a weighted average of impervious and lawn (good condition, type A soils) Runoff Q Frequency (year) 1 10 Rainfall, P aka 24 hour)* 3.75 7.06 Pre -Runoff, Q (in)— 0.64 2.65 Post -Runoff, Q (in)** 1.17 3.68 Intensity, 124 hour)* 0.156 0.294 Pre Development Peak runoff from 1 year 24 hour storm = C * I * A = Pre Development Peak runoff from 10 year 24 hour storm = C * I * A = Post Development Peak runoff from 1 year 24 hour storm (w/o detention) = C * I * A = Post Development Peak runoff from 10 year 24 hour storm (w/o detention) = C * I * A = 0.07 CFS 0.12 CFS f.w. 'RECEIVE 0.19 CFS 0.37 CFS JUL 0 5 202 *Rainfall data per NOAA Atlas 14 0 aV **where Q = ((P - 0.25)) / (P + 0.85) and S = (10001 CN) - 10 BY: DEQ 1 yr 24 hr Pre/Post Method Pre R = 0.05 + 0.9 * Impervious Ratio Rv = 0.050 Post R = 0.05 + 0.9 * Impervious Ratio Rv = 0.524 Control Volume = 3630 * Rd * R * A where Rd = 3.75 Predevelopment runoff-- 1427 cf Postdevelopment runoff-- 14966 cf Water Quality Required Storage= I 13538 cf Schuler's Simple Method NA R = 0.05 + 0.9 * Impervious Ratio Rv = 0.524 Control Volume = 3630 * Rd * R * A where Rd = 1.5 in. Water Quality Required Storage= 5986 cf CONTROLS USE: 13538 CIF FOR POND DESIGN Basin Dimensions R.1— P.—...n4 P-1 El. I SA Forebay Inc. Volume Forebay Total Volume Forebay SA Pond Inc. Volume Main Pond Total Volume Main Pond -9.01 0 0 0 0 0 0 -8.01 0 0 0 0 0 0 -7.01 0 0 0 0 0 0 -6.01 0 0 0 0 0 0 -5.0 0 0 0 0 0 0 4.0 0 0 0 0 0 a -3.0 0 0 0 0 0 0 -2.0 12 0 0 910 0 0 -1.0 103 58 58 1333 1122 1122 0.0 258 181 238 1781 1557 2679 1.0 412 335 573 2254 2018 4696 2.0 591 502 1075 2754 2504 7200 3.0 1213 902 1977 4348 3551 10751 % Forebay= 18.4% % is 15%-20%, OK c-Pond Bottom El =Sediment Removal El c-Permanent Pool El Ik-P JUL 0 5 ,2018 uv: State Reauired Deoth/Surface Area Calculation Vpp (main pond)= (main pond)= Shelf Width Perimeter,,,,,,,, 1pl (main pond)= D,,,,,,,= Desired TSS Removal Capacity-- Enter Table 10-4 SAIDA lower depth interval: Impervious Cover= Table 10-4 SA/DA;ower %BUAinterval: Enter Table 10-4 SAIDA values for depth and %BUA: 10751 cf sf ft ft ft is > 3.0', OK (submerged shelf) ) 5-1 1-1 ft _ ? !mod / 3.5 4348 6 305 90 3.5 52.7% 1 40% 1 4.0 1 Calculated SAIDA= 5.16 Required Surface Area= 4715 sf Permanent Pool SA= `556_1 sf is > required SA, OK Ahnvo Pnrmanon4 Pnnl EL. Stage SA Inc. Vol. Pond Total Vol. Pond 3.0 0.0 5561 0 0 3.5 0.5 6154 2929 2929 4.0 1.0 6766 3230 6159 4.5 1.5 7397 3541 9700 5.0 2.01 80471 3861 13561 5.51 2.51 8716 4191 17751 6.01 3.01 94041 4530 22281 Stale Stage= State EI = Top EI = Freeboard= 2.00 ft 5.00 ft 6.00 1.00 ft 2.5 Day Drawdown for State Volume Max (2 Day) Flow= 0.08 cfs Min (5 Day) Flow= I 0.03 ds Slot Stage= 2.00 It Avg Head= 0.67 ft 2 Day Area= 0.020 sf 5 Day Area= I 0.008 sf 2 Day Diameter-- 1.913 in 5 Day Diameter= I 1.210 in Provide Orifice= 1.50 in Drawdown Flow-- 0.05 cfs Drawdown Time= 3.3 days 78 hours is > 1.0', OK is < predevelopment discharge from 1 year 24 hour storm, OK Is within 2-5 days, OK eGEIVE JUL 0 52018 II BY: q '..�L. �IL0WM § L2L /� (7 §§ k2 )2 § 2 § 2: 2 §« _� § }� }/ . a ¥® a /( L )CL / } � � / ®«� e /\k§ 0 #m qP m R \§ §w a k § § § § 8 2 < < = a § e 3 ; Q a f% 9§ a 2 7 7 cq f § L6 § § \ f § § 2 / § ° / f 2 ) § § § -'i ci ci q ci Iq 3§� §§ §§ / § [ k G R ceiviEJUL 0 f 2 @� 0 2 o r It LL a o o o a w J O O O g j 00 0 U n n n n 0 0 0 0 Z O z z O_ W a w ❑ n uD N n n m ID F N V m U 0 O a Q a IL a W Z W U QQ EIVE• m o Z Q NNN N co oQ °LLCIE JUL 052018 r 0 0 0 O 0 z g F a O Lii 0 a o CD a w 0 0 i q \ kLu ( LLCD ,, F - z= ) . - ,ow }(!C' 00wtoo28 \ § / %kea��w� w§\§( U < (If0(k\( §7m`> • $ (§\\> 0§§ ZZ02§;;; o « $$© �VV ` 2 / < 0\§2L g M§2 2 § 2 { )/[05 § ))j } \ 0.(2feaRm §Mk B/&< 3& o § m§ 2 [ ¥¥§) / b L[� �) \ ;�\m [�k - . ) ( « ) k vo § § Cd * �A t- z !11 d(((� LLI § ( it z.Ir §!{ q ^ w LLI , b § � § \ m nZ,It [\ 90 ) }� L�G§� )� 2 §k k ; P< z �) 0 § omw lw Q[ > % �2 (§o K 2 §£]§ ¥/� e 8 w § / & - § § w E j- - R§� § �2 \ (§] § � ; §" -I 3/ §z LLI § § /§ [§ §§§ )§ § C. 2§G § § /\ In In /§ cc §[ \\§ \§ m LLj (L It owo [ EC EFIV E \ JUL 0§201 . BY: 6/14/2018 Project Narrative Vot 45-A iH Batts Division NC Hwy 50 Surf City, NC The 2.10 acre site is located along NC Hwy 50 on the mainland portion of the Town of Surf City in Pender County, NC. The site is zoned C-3. Proposed improvements are consistent with this zoning and include an office with accessory building. The site is presently vacant and is vegetated with a stand of 10" - 20" pine trees. No significant trees are located onsite. The site drains to Topsail Sound via a an existing ditch leading to and existing culvert under NC 50. Access to the site is proposed by driveways off of NC 50. Internal drive aisle widths are sufficient to allow fire apparatus access. Water and sewer service will be provided by the Town of Surf City via service taps on existing mains in NC 50. Stormwater runoff will be collected by inlets and conveyed via pipe to an NCDE Q wet pond designed to treat and release the difference between the pre and post development 1 year, 24 hour storm in 2-5 days. This NCDEQtreatment volume is released at a rate that does not exceed the 1 year, 24 hour predevelopment runoff rate. Erosion control is accomplished through the temporary use of a gravel construction entrance, silt fence, and hardware cloth and gravel inlet protection. The stormwater pond will be used as a skimmer basin during site construction and will be converted to a stormwater basin once the site is stabilized. Riprap aprons will be installed and left in place at all pipe outlets. �EGEIVE JUL O 51018 sr:_� �� ,'� - .,. r ,� , •-dam='�^: � �, f 1 v... ♦ _� -fir � {% Y� ' ✓ J V�HERON S cam- % Alpo 10 ''' Bat/ A � ai to �lY ✓. . or 10 TA 1�COCKLEST `�~ ~ - :L���� KIAISTOyRQ I 1 ✓r 1 - ,w i t.' _� � _SPIQT LN \ -V J' l f" ju 6Y: 6/6/2018 Precipitation Frequency Data Server 0NOAA Atlas 14, Volume 2, Version 3 Location name: Holly Ridge, North Carolina, USA* Latitude: 34.4376', Longitude:-77.655' Elevation: 7.21 ft** * source: ESRI Maps ** source: USGS POINT PRECIPITATION FREQUENCY ESTIMATES C.M. Bonnin, D. Martin, B. Lin, T. Parzybok, M. !ekta, and D. Riley NOAA, National Weather Service, Silver Spring, Maryland PF tabular I PF graphical I Maps & aerials PF tabular Duration Average recurrence interval (years) 7 ���������� 2 5 10 25 50 100 200 500 1000 6.02 7.15 8.36 9.31 10.5 11.4 12.3 13.3 14.5 15.5 5-min (5.58-6.53) 1 (6.62-7.75) 1 (7.73-9.05) (8.58-10.1) (9.64-11.4 10.4-12.3) (11.2-13.3) (12.0-14.4) (12.9-15.7) (13.7-16.8) 4.81 5.72 6.70 7.45 8.38 9.10 9.81 10.5 11.4 12.2 70-min (4.46-5.21) 1 (5.30-6.20) 11 (6.19-7.25) (6.86-8.05) (7.68-9.04) (8.30-9.82) 8.91-10.6 (9.49-11.4) (10.2-12.4) (10.8-13.2) 4.01 4.79 5.65 7 F 6.28 7.08 7.68 8.27 8.85 9.61 10.2 75-min 3.71-4.34) 1 (4.44-5.20) 11 (5.22-6.11) 1 (5.79-6.79) 1 (6.49-7.64) 1 (7.01-8.29) 1 (7.51-8.93) 1 (7.98-9.56) 11 (8.58-10.4 (9.02-11.1) 2.75 3.31 4.01 4.55 5.24 5.78 6.33 6.89 7.64 8.25 30-min 2.55-2.98) 3.07-3.59 (3.71-4.34) 1 (4.19-4.92) 1 (4.81-5.66) 1 (5.28-6.24) 11 (5.75-6.84) 1 (6.21-7.45) 11 (6.83-8.28) 1 (7.30-8.96 1.71 2.08 2.57 2.96 3.49 3.92 4.36 4.83 5.48 6.02 60-min (1.59-1.86) 1 (1.92-2.25) 11 (2.38-2.78) 1 (2.73-3.20 (3.20-3.77) (3.58-4.23) (3.96-4.71) (4.36-5.22) (4.905.94) (5.33-6.54) 1.04 1.27 1.62 1.90 2.31 2.65 3.02 3.42 4.01 4.51 2-hr (0.962-1.14) 11 (1.18-1.39) 11 (1.49-1.76) 1 (1.75-2.07) (2.11-2.51) (2.41-2.88) (2.73-3.28 3.07-3.72) (3.55-4.36) (3.96-4.92) 0.748 0.913 1.17 1.38 1.70 1.97 2.27 2.61 3.11 3.54 3-hr (0.690-0.820) (0.842-1.00) 1 (1.07-1.28) 1 (1.26-1.51) 1 (1.55-1.85) 1 (1.78-2.15) 1 (2,04-2.48) (2.31-2.84) (2.72-3.39) (3.07-3.87) 0.460 0.562 0.719 0.854 1.05 1.23 7.42 1 ;3 1.95 2.23 6-hr (0.422-0.507)1(0.515-0.620 (0.657-0.793) (0.777-0.940) (0.952-1.16) 1 (1.10-1.34) 1 (1.26-1.55) 1 (1.44-1.79) 1 (1.70-2.14) (1.92-2.45 0.270 0.329 0.424 0.506 0.628 0.735 0.856 0.991 1.20 1.38 72-hr (0.245-0.300) (0.298-0.366) (0.384-0.471) 0.456-0.562 0.561-0.695) 0.652-0.812) (0.753-0.945) (0.863-1.09) 1 (1.03-1.32) 1 (1.17-1.53) 0.156 0.190 0.246 0.294 0.367 0.431 0.503 0.585 0.709 0.818 24-hr (0.144-0.172) (0.175-0.209) (0.225-0.270) (0.269-0.322) (0.332-0.402) (0.386-0.472) (0.446-0.551)1(0.511-0.641)1(0.607-0.782 (0.689-0.907) 0.091 0.110 0.142 0.169 0.210 0.246 0.286 0.332 0.402 0.462 2-day 0.084-0.100 (0.101-0.122) 0.129-0.156) (0.154-0.186) (0.189-0.231) (0.220-0.271) (0.253-0.316) 0.290-0.368) (0.343-0.448) 0.388-0.519 0.064 0.078 0.099 0.178 0.145 0.169 0.195 0.225 0.270 0.310 3-day (0.059-0.071) (0.071-0.086) (0.091-0.109)1(0.107-0.129 (0.131-0.159)11(0.152-0.186) (0.173-0.215) 0.197-0.248) (0.232-0.300) (0.262-0.347) 0.051 0.062 0.076 0.092 0.113 0.130 0.750 0.171 0.205 0.233 4-day (0.047-0.056) (0.057-0.068) (0.072-0.086) (0.084-0.101) (0.102-0.123) 1(0.117-0.143 0.134-0.164) (0.151-0.189) (0.177-0.227) (0.199-0.261) 0.034 0.040 0.051 0.059 0.072 0.083 0.094 0.106 0.124 0.140 7-day (0.031-0.036) (0.037-0.044) (0.047-0.055) (0.055-0.o65) (0.066-0.078) (0.075-0.090) (0.085-0.102) (0.095-0.116) 1(0.109-0.137 (0.120-0.154) 0.026 0.031 0.039 0.045 0.054 0.062 0.070 0.078 0.091 0.101 10-day (0.024-0.028) 1(0.029-0.034 (0.036-0.042) (0.042-0.049) (0.050-0.059) (0.056-0.067) (0.063-0.076) (0.070-0.085) (0.080-0.100) (0.088-0.112 0.077 0.021 0.025 0.029 0.034 0.038 0.043 0.048 0.055 0.060 20-day (0.016-0.019) (0.019-0.022) 0.023-0.027 0.027-0.031 (0.031-0.036) (0.035-0.041) (0.039-0.046) (0.043-0.052) (0.049-0.059) (0.053-0.066) 0.014 0.017 0.020 0.023 0.027 0.030 0.033 0.036 0.040 0.044 30-day (0.013-0.015) (0.016-0.018) (0.019-0.021) (0.021-0.024) (0.025-0.028) 1(0.027-0.032 (0.030-0.035) (0.033-0.038) (0.036-0.043) (0.039-0.047) 0.012 0.014 0.017 0.019 0.022 0.024 0.027 0.029 0.033 0.035 45-da y (0.011-0.013) (0.013-0.015) (0.016-0.018) (0.018-0.020) (0.020-0.023) (0.022-0.026) (0.025-0.029) 0.027-0.031 (0.030-0.035) (0.032-0.039) 0.011 0.013 0.015 0.017 ().019 0.021 0.023 0.025 0.027 0.029 60-day (0.010-0.011)11(0.012-0.013 (0.014-0.016) (0.016-0.018) (0.018-0.020) (0.020-0.022) (0.021-0.024) (0.023-0.026) (0.025-0.029) 0.026-0.031 ft https://hdsc.nws.noaa.gov/hdscipfdslpfds_printpage.html?lat=34.4376&Ion=-77.5550&data=intensity&units=engiish&series=pds 1A 6/6/2018 Precipitation Frequency Data Server NOAA Atlas 14, Volume 2, Version 3 Location name: Holly Ridge, North Carolina, USA* ° Latitude: 34.4376*, Longitude:-77.555* Elevation: 7.21 ft** ' source: ESRI Maps ti ** source: USGS POINT PRECIPITATION FREQUENCY ESTIMATES G.M. Bennin, D. Mart!n„ B. Lin, T Pazybek, M `lekta, and D. Riley NOAA, National Weather Service, Silver Spring, Maryland PF tabular I PF graphical j Maps & aerials PF tabular PDS-based point precipitation frequency estimates with 90% confidence intervals (in inches)1 Average recurrence interval (years) Duration 1 2 5 10 25 50 100 200 ��� 500 1000 0.502 6.596 0.697 0.776 0.876 0.952 1.03 1.11 1.21 1.29 5-min (0.465-0.544) (0.552-0.646) (0.644-0.754)11(0.715-0.839) (0.803-0.946) (0.869-1.03) (0.934-1.11) (0.998-1.20) (1.08-1.31) 1(1.14-1.40 0.802 6.953 1.12 1.24 1.40 1.52 1.64 1.75 1.91 2.03 10-min (0.743-0.868) (0.883-1.03) (1.03-1.21) 11 (1.14-1.34) 11 (1.28-1.51) (1.38-1.64) (1.49-1.77) (1.58-1.90) (1.70-2.07)1(1.80-2.20) 1.00 1.20 1.41 1.57 1.77 1.92 2.07 2.21 2.40 2.55 15-min (0.928-1.09) 1 (1.11-1.30) 1 (1.31-1.53) 11 (1.45-1.70) 1 (1.62-1.91) (1.75-2.07) (1.88-2.23) (2.00-2.39) (2.15-2.60) (2.26-2.77) 30-min 1.27-31749 1.53-61679 1.85-2.17 2. 0 2846 (2. 0 2?83) 11(2.64 3912 2.8713.42 3.11 3.72 (3.41-4.14) (3. 5 4.48) 7.71 2.08 2.57 2.96 3.49 3.92 4.36 4.83 5.48 6.02 60-min (1.59-1.86) 1 (1.92-2.25) 1 (2.38-2.78) 1 (2.73-3.20) 1 (3.20-3.77) (3.584.23) (3.96-4.71) (4.36-5.22) 4.90-5.94) 5.33-6.54 2.09 2.55 3.24 3.81 4.62 5.30 6.04 6.85 8.02 9.01 2-hr (1.92-2.27) 1 (2.35-2.78) 11 (2.98-3.53) 1 (3.504.14) (4.2-5.02) (4.82-5.76) (5.45-6.56) (6.13-7.43) (7.11-8.72) (7.92-9.83) 2.25 2.74 3.57 4.15 5.10 5.92 6.82 7.82 9.32 10.6 3-hr (2.07-2.46) 1 (2.53-3.01) 11 (3.2-3.84) (3.804.54) (4.64-5.57) (5.35-6.46) (6.12-7.44) (6.95-8.52) (8.18-10.2) (9.21-11.6) 2.75 3.36 4.31 :i.17 6.30 7.33 u.48 ^a.76 77.7 73.�i 6-hr ( 2.53-3.04 3.09-3.71 3.944.75 4.65-5.63 5.70-6.92 6.58-8.05 7.55-9.30 8.60-10. ( 10.2-12.8) ( 11.5-14.7) 3.25 3.96 5.11 6.09 7.57 8.86 10.3 11.9 14.4 16.6 12-hr (2.95-3.61) (3.60-4.41) (4.62-5.68) (5.49-6.77) (6.76-8.38) (7.86-9.79) (9.07-11.4) (10.4-13.2) 12.4-15.9 14.1-18.4 3.75 4.56 5.90 7.06 8.61 10.3 12.1 14.0 7 F 17.0 99.6 24-hr (3.454.12) (4.19-5.02) (5.41-6.48) (6.44-7.73) (7.97-9.64) (9.27-11.3) (10.7-13.2) (12.3-15.4) (14.6-18.8) (16.5-21.8) 2-day -18.92) 3.0) (4.024.82) 4.865084 6. 2-87049 (7.8 11 (9.09- 1.1) (1 .6- 1(12.4- 5.2 (13.9-1�7.7) (16.5-21.5) (18 6? 4.9) 4.64 5.67 7.75 8.47 10.5 12.2 74.1 16.2 19.5F 22.3 3-day (4.265.09) (5.15-6.16) (6.55-7.86) (7.73-9.30) 1 (9.46-11.5) (10.9-13.4) (12.5-15.5) (14.2-17.9) j(16.7-21.6) 18.8-25.0 4.89 5.91 7.50 8.85 10.8 12.5 14.4 16.4 79.6 22.4 4-day (4.505.36) (5.44-6.48) (6.88-8.22) (8,08-9.69) (9.82-11.8) (11.3-13.7) (12.8-15.8) (14.5-18.1) (17.0-21.8) ( 19.1-25.0) 5.63 6.79 8.53 9.99 12.1 13.9 15.8 17.9 20.9 23. 4 7-day (5.21-6.12) (6.28-7.38) (7.88-9.27) (9.18-10.8) (11.1-13.1) (12.6-15.1) (14.2-17.2) (15.9-19.5) (18.3-23.0) ( 20.2-25.9) 6.27 7.51 9.37 10.8 13.0 14.8 16.7 18.8 21.8 24.3 10-day 5.81-6.81 6.96-8.16) (8.61-10.1) 11 (9.96-11.7) 1 (11.9-14.0 (13.5-16.0)11(15.1-18.2) (16.8-20.5) (19.2-24.0) (21.1-26.9) 8.29 9.88 12.0 13.8 16.3 18.4 20.6 22.9 26.2 28.8 20-day (7.75-8.92) (9.23-10.6) (11.2-12.9) 1 (12.8-14.8) 1 (15.1-17.5) (16.9-19.8) (18.8-22.2) 20.7-24.8 23.3-28.5 25.4-31.6) 10.7 12.0 14.5 16.4 19.1 21.3 23.5 25.8 28.9 31.4 30-day (9.51-10.8) (11.3-12.8) (13.6-15.4) 11 (15.4-17.5) 1 (17.8-20.4) (19.7-22.7) (21.7-25.2) (23.6-27.7) (26.2-31.3) (28.2-34.1) 72.7 15.1 77.9 20.2 23.5 26.1 28.7 31.5 35.3 38.3 45-day (12.0-13.6) (14.1-16.1) (16.8-19.2) 11 (18.9-21.7) 1 (21.9-25.1) (24.2-27.9) (26.5-30.9) (28.8-33.9) (32.0-38.2) (34.341.7) 15.4 78.2 21.4 23.9 27.4 30.7 32.8 35.5 39.1 41.9 60-day 14.6-16.4 (17.2-19.4) 20.2-22.7) (22.5-25.4 25.7-29.1 28.1-32.0 30.5-34.9) 32.8-37.9) (35.8-42.1) (38A45.3) Precipitation frequency (PF) estimates in this table are based on frequency analysis of partial duration series (PDS). Numbers in parenthesis are PF estimates at lower and upper bounds of the 90% confidence interval. The probability that precipitation frequency estimates (for a given duration and average recurrence interval) will be greater than the upper bound (or less than the lower bound) is 5%. Estimates at upper bounds are not checked against probable maximum precipitation (PMP) estimates and may be higher than currently valid PMP values. Please refer to NOAA Atlas 14 document for more information. Back to Top PF graphical EC IV1E JUL 0 51118 https://hdsc.nws.noaa.gov/hdacipfdsipfds_printpage.htmi?fat=34.4376&Ion= 'i1.5550&data=depth&units=engiish&series=pds 1/4 rlt. eD- . Q8 APR 25 PM Z. SI JLIYCE al. SWXtGOOD pREGISTER OF OEEOS ..(, — PIN # L03S'3`7- tPG IO�� rY, NC OA -a5 D8 BK345OPG183 W2 I PREPARED BY CHARLES T. BUSBY, LAW OFFICE OF LADD GASPAROVIC, PA, P,O. BOX e1 B, HAMPSTEAD, NORTH CAROLINA 26443 NORTH CAROLINA GENERAL WARRANTY DEED PENDER COUNTY Revs e: $O PIN: 4235-37-465 1 -0000 THIS DEED made this 25ei day of April, 2008, by and between SURF CITY GATEWAY PLAZA, INC., Party of the First Part; to A 'N' A BUILDERS, INC., a North Carolina Corporation, 9312 North Manor Drive, Zebulon, North Carolina 27597, Party of the Second Part; WITNESSETH: That the party of the first part, for and in consideration of the sum of TEN DOLLARS ($10.00) and other valuable consideration paid by the party of the second part, the receipt of which is hereby acknowledged, has and by these presents does grant, bargain, sell and convey unto the party of the second part in fee simple, all that certain parcel of land situated in Topsail Township, Pander County, North Carolina and more particularly described as follows: The parcel of land located adjacent to and East of Highway 50, consisting of 0.33 Acres, and being depicted as "REVISED OUTPARCEL B" on plat entitled "AS BUILT SURVEY OF GATEWAY PLAZA - OUTPARCEL "B", dated 08/10/06 and recorded in Map Book 42, page 83, Slide 568, to which reference is made for complete description, being a portion of the land conveyed to Surf City Gateway Plaza, Inc. by deed recorded in Book 2515 at page 080, Pender County. Recorded and Verified Joyce M. Swicegood Register of Deeds Ponder County, NC rwi 0 JUL 01 2018 BY: 3�r�,o vcs V:Zy TO HAVE AND TO HOLD the aforesaid lot or ONFRO"Ja%all privileges and appurtenances thereto belonging to the party of the second part, its successors and assigns, in fee simple. And the said party of the first part covenants to and with the party of the second part, its successor and assigns, that it is seized of said premises in fee simple, that it has the right to convey the same in fee simple, that title is marketable and free and clear of all encumbrances, and that it will warrant and defend the title against the lawful claims of all persons whomsoever. IN WITNESS WHEREOF, the party of the first part has caused this instrument to be signed in its corporate name by its authorized official as of the day and year first above written. SJRF CITY GATO:W."•.Y PLAZA, INC. XBy: Mohamad E. Afify, Pr s ent NORTH CAROLINA PENDER COUNTY 1, the undersigned Notary Public, do hereby certify that Mohemad E. Afify appeared before me this day and acknowledged that he is President of Surf City Gateway Plaza, Inc., a North Carolina corporation, and that he, as president, being authorized to do so, executed the foregoing on behalf of the corporation. WITNESS my hand and notarial seal this 25t" day of April, 20d8. ,,�01Hn1111% 3 My Commission expires: /2 2p9 0 .�_65 T Notary Public Cj.�•'"'��•"''• ltkoTAq�'04 e oyN A'013 10)p ,s�°�y'�•......� '' fir.• �k COUP `., bN141NN i JUL 0 5 2018 f t BUSINESS CORPORATION ANNUAL REPORT 10-2017 NAME OF BUSINESS CORPORATION: A'N' A BUILDERS, INC. SECRETARY OF STATE ID NUMBER: 0490251 STATE OF FORMATION: NC REPORT FOR THE FISCAL YEAR END: 1 2/31 /201 7 SECTION A: REGISTERED AGENT'S INFORMATION 1. NAME OF REGISTERED AGENT: AFIFY, ANITA T. 2. SIGNATURE OF THE NEW REGISTERED AGENT: 3. REGISTERED OFFICE STREET ADDRESS & COUNTY Filing Office Use Only E-Filed Annual Report 0490251 CA201806601568 3/7/2018 09:06 Changes SIGNATURE CONSTITUTES CONSENT TO THE APPOINTMENT 4. REGISTERED OFFICE MAILING ADDRESS 13480 NC Hwy 50 13480 NC Hwy 50 Surf City, NC 28445-6552 Pender County Surf City, NC 28445-6552 SECTION B: PRINCIPAL OFFICE INFORMATION 1. DESCRIPTION OF NATURE OF BUSINESS: Construction 2. PRINCIPAL OFFICE PHONE NUMBER: (910) 329-9800 3. PRINCIPAL OFFICE EMAIL: Privacy Redaction 4. PRINCIPAL OFFICE STREET ADDRESS & COUNTY 13480 NC Hwv 50 Surf City, NC 28445-6552 5. PRINCIPAL OFFICE MAILING ADDRESS 13480 NC Hwy 50 Sun` City, NC 28445-6552 6. Select one of the following if applicable. (Optional see instructions) ❑ The company is a veteran -owned small business ❑ The company is a service -disabled veteran -owned small business S CTION C: OFFICERS (Enter additional officers in Section E.) NAME. Mohamad Afify NAME: Anita T Afify NAME: TITLE: Secretary TITLE: President ADDRESS: 13480 NC Hwv 50 Surf City, NC 28445 ADDRESS: 13480 NC Hwy 50 Surf City, NC 28445 TITLE: ADDRESS: SECTION D: CERTIFICATION OF ANNUAL REPORT. Section D must be completed in its entirety by a person/business entRinita T Aflfy 3/7/2018 A SIGNATURE Form must be signed by an officer listed under Section C of this form. DATE Anita T Afify President►,i< Print or Tvne Name of nffirEr Print or Type Title of 1� This Annual Report has been filed electronically. JUL 0 5 tow MAIL TO: Secretary of State, Business Registration Division, Post Office Box 29525, Raleigh, NC 27626-0525 8Y: June 27, 2018 To Whom it May Concern: 1, Anita T. Afify, President, A `N' A Builders, Inc., hereby authorize Mohamad Afify, Secretary, A `N' A Builders, Inc., to sign NCDEQ applications on behalf of A `N' A Builders, Inc. A' AB 'lders, Inc. By: Anita T. Afify, P i ent State of North Carolina, County of.pn Subscribed and sworn to before me this day of -Jq-w- , 20 le Notary: 71 My commission expires: a3a FJ:UUE FIT�RALD AWPUBLIC Ct31JNTY, NC w EVkw 2 2�2022 r JUL 0 5 2018 Scott, Georgette From: Scott, Georgette Sent: Tuesday, June 26, 2018 3:18 PM To: 'Luke Menius'.(Imenius@stroudengineer.com) Subject: Lot 45-A JH BATTS DIVISION Luke, I've reviewed this package and need the following issues corrected before I can accept it: ✓1. The check is for $550.00 instead of $505.00. So I need a new check made out to NCDEQ ,//2. Mohamad Afify signed the application. Mohamad is listed as "Secretary". Per our rules the application m t be signed by a President, VP or Manager. So you can have all the signature pages resigned by the presideZ you can send me a leal docu gment signed by the com ap ny president that states that he can sign for the company. Georgette ScoffG'� Isli State Stormwater Program Supervisor ! Department of Environmental Quality Office (910) 796 7215 Fax (910) 350-2004 G e o rq ette. Sc6ft6- n cd e n r. a ov 127 Cardinal Drive Ext. Wilmington, NC 28405 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties.