Loading...
HomeMy WebLinkAboutSW5100602_Supplement-EZ Form_20230526DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so, number of drainage areas/SCMs 1 3 Does this project have low density areas? No 4 If so, number of low density drainage areas 0 5 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 4 Type of SCM Wet Pond 5 Total drainage area (sq ft 442572 442572 6 Onsite drainage area (sq ft 442572 442572 7 Offsite drainage area (sq ft 0 0 8 Total BUA in project (sq ft 250795 sf 250795 sf 9permitting) New BUA on subdivided lots (subject to s ft sf sf 10permitting) New BUA not on subdivided lots (subject to sf sf sf 11 Offsite BUA (sq ft sf sf 12 Breakdown of new BUA not on subdivided lots: - Parking (sq ft 89663 sf 89663 sf - Sidewalk (sq ft 1115 sf 1115 sf - Roof (sq ft sf sf - Roadway s ft sf sf - Future (sq ft 9763 sf 9763 sf - Other, please specify in the comment box below (sq ft 150254 sf 150254 sf 13 New infiltrating permeable pavement on subdivided lots (sq ft sf sf 14 New infiltrating permeable pavement not on subdivided lots (sq ft sf sf 15permitting) Existing BUA that will remain (not subject to s ft na na 16 Existing BUA that is already permitted (sq ft 17 Existing BUA that will be removed (sq ft sf sf 18 Percent BUA 22% 22% 19 Design storm inches 1.0 in 1.0 in 20 Design volume of SCM cu ft 20629 cf 20629 cf 21 Calculation method for design volume Equation 2 Equation 2 ADDITIONAL INFORMATION 22 Please use this space to provide any additional information about the drainage area(s): "Other" includes the onsite buildings. "Future" was previously 41,688 in 2018 w/ 31,925 sf now (2023) being used for a parking lot expansion.