Loading...
HomeMy WebLinkAboutNC0049867_Staff Report_19940216DIVISION OF ENVIRONMENTAL MANAGEMENT February 16, 1994 Memorandum To: Jay Lucas From: \, D. Rex Gleasonj�ol_� J. Prepared By: Kim H. Colson Subject: Town of Cleveland WWTP NPDES Permit No. NC0049867 Rowan County, NC This Memorandum serves as a modification to the staff report dated April 7, 1993, which was completed as part of the renewal process. This Office has reviewed the request for increase in flow at the subject facility and has no objection to the proposed increase in flow provided that the Technical Support Branch concurs. All other information and recommendations in the staff report have not changed. If you have any questions concerning this matter, please advise. 5 or. SOC Priority Project: Yes No X If Yes, SOC No.: To: Permits and Engineering Unit Water. Quality Section Attention: Gha&Les. -,Lowe Date : April 7, 1993 --2� a / 1 S"e, NPDES STAFF REPORT AND RECOMMENDATION County: Rowan Permit No. NCO049867 PART I - GENERAL INFORMATION 1. Facility and Address: Town of Cleveland WWTP Post Office Box 1.85 Cleveland.. North Carolina 27013 2. Date of Investigation: April 7, 1993 3. Report Prepared by: Kim H. Colson, Environmental Engineer. I 4. Persons Contacted and Telephone Number: Thurman Miller., ORC, (704) 278-4777 5. Directions to Site: From the intersection of GS Hwy 70 and SR 1743 (Bear Poplar Road) in the Town of Cleveland, travel north on SR 1743 approximately 0.7 mile. Turn left onto SR 1957 (Third Creek Church Road) and travel north approximately 0.9 rr►i1e . The WWTP is located on Die left. (west) side of SR 1957 just before Third Creek. 6. Discharge Po.int(s), List for all discharge points: Latitude: 35' 4438" Longitude: 80' 40' 56" Attach a USGS map extract and indicate treatment facility site and discharge point on map. U.S.G.S. Quad No.: E16NW U.S.G.S. Quad Name: Cleveland, NC 7. Site size and expansion area consistent with application? There is land available for limited upgrading and expansion. 8. Topography (relationship to flood plain included): Moderate sloping; the WWTP is not located within the 100 year flood plain. 9. Location of nearest dwelling: One dwelling is located approximately 300 feet: from the WWTP. 1/ Page Two 10. Receiving stream or affected surface waters: Third Creek a. Classification: C b. River Basin and Subbasin No.: Yadkin - Pee Dee 030706 C. Describe receiving stream features and pertinent downstream uses: Receiving stream is a large creek with sandy/muddy bottom. General "C° classification uses downstream. PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of wastewater to be permitted: 0.090 MGD (ultimate dt-)sign capaciZy4._.._ b. Current permitted capacity of the wastewater treatment facility: 0.090 MGD C. Actual treatment capacity of the current facility (current design capacity): 0.090 MGD d. Date(s) and construction activities allowed by previous Authorizations to Construct issued .in the previous two years: N/A e. Please provide a description of existing or substantially constructed wastewater treatment facilities: Existing treatment facilities consist of a bar screen, oxidation ditch, secondary clarifier, chlorine disinfection, effluent flow measurement., and sludge drying beds. f. Please provide a description of proposed wastewater treatment facilities: There are no immediate plans for expansion or upgrading. g. Possible toxic impacts to surface waters: There are two industries which discharge into the Towns collection system.. It is unknown whether any industrial wastewater is discharged into the collection system that may have toxic impacts to surface waters. h. Pretreatment: Program (POTWs only): The Town does not have an approved pretreatment program; however, a pretreatment program may be necessary if industries are contributing significant amounts of industrial wastewater. 2. Residuals handling and utilization/disposal scheme: Sludge will be taken to a municipal landfill for use in the final cover. a. If residuals are being land applied, please specify DEM Permit No.: N/A Residuals Contractor: N/A Telephone No.: N/A Page Three b. Residuals stabilization: N/A C. Landfill: N/A d. Other disposal/utilization scheme (Specify): N/A 3. Treatment plant classification (attach completed rating sheet): Class II 4. SIC Code(s): 4952 Wastewater Code(s) Primary: 01 Secondary: Main Treatment Unit: Code: IDODQ.- PART III — OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or are any public monies involved (municipals only)? N/A 2. Special monitoring or limitations (including toxicity) requests: Additional monitoring may be required if industrial - users contribute significant, process wastewater. 3. Important SOC, JOG or Compliance Schedule dates (Please indicate): N/A 4. Alternative Analysis Evaluation: Spray Irrigation: N/A Connection to Regional Sewer System: N/A Subsurface: N/A Other disposal. options: N/A 5. Air Quality and/or Groundwater concerns or hazardous materials utilized at this facility that may impact water quality, air quality, or groundwater: There are no known Air Quality, Groundwater or hazardous materials concerns. 6. Other Special Items: N/A PART IV — EVALUATION AND RECOMMENDATIONS The permittee, Town of Cleveland, has applied for permit renewal. The Town may also be expanding the WWT facilities in the future, however, no modification in the existing permit has been requested. Page Four The Town currently has two industries which contribute mainly domestic wastewater.. The amount or type of industrial waste that is discharged into the WWTP is unknown. It is possiblethat the .industries conduct some type of metal finishing operations.' It is recommended that the permit be renewed with requirements for conducting an Industrial Waste Survey, Once the results of the survey are known, the Permitt can be reopened to include addit..ional. effluent monitoring/limits, if necessary. we not Signature of report prmparer._ Water Quality '.gional Supervisor Date