Loading...
HomeMy WebLinkAbout090204_routine_202302230 Division of Water Resources ❑ Division of Soil and Water Conservation ❑ Other Agency Facility Number: 090204 Facility Status: Active Permit: AWS090204 ❑ Denied Access Inspection Type: Compliance Inspection Reason for Visit: Routine Date of Visit: 02/24/2023 Entry Time: Farm Name: Mr. Holmes Sites #15 & #16 Owner: Murphy -Brown LLC Mailing Address: PO Box 487 Physical Address: 1097 Boss Hog Rd 09:00 am Inactive Or Closed Date: County: Bladen Region: Fayetteville Exit Time: 12:00 pm Incident #: Owner Email: Phone: 910-296-1800 Warsaw NC 283980487 Garland NC 28441 Facility Status: 0 Compliant ❑ Not Compliant Integrator: Murphy -Brown LLC Location of Farm: Latitude: 34' 50' 20" Longitude: 78' 31' 52" From the intersection of NC 242 and SR1002 in Ammon, go 2.0 miles north on NC 242 to farm entrance on right Question Areas: Dischrge & Stream Impacts Waste Col, Stor, & Treat Waste Application Records and Documents Other Issues Certified Operator: William Victor Sutton Operator Certification Number: 26076 Secondary OIC(s): On -Site Representative(s): Name Title Phone 24 hour contact name Mike Cudd On -site representative Mike Cudd Primary Inspector: Steve Guyton Phone: 910-433-3300 Inspector Signature: Date: Secondary Inspector(s): Inspection Summary: 9. Clean up sludge at back of houses at first set and second set.determin what caused this and fix the issue records reviewed offsite on another day Page 1 of 5 Permit: AWS090204 Owner: Murphy -Brown LLC Facility Number: 090204 Inspection Date: 02/24/23 Inspection Type: Compliance Inspection Reason for Visit: Routine Regulated Operations Design Capacity Current promotions Swine Swine - Feeder to Finish 7,344 I 7,344 Total Design Capacity: 7,344 Total SSLW: 991,440 Waste Structures Effective Built Closed Designated Observed Type Identifier Date Date Date Freeboard Freeboard Lagoon 15&16 11/03/2005 10/01/2019 32.00 50.00 Lagoon HOLMES 15&16 03/08/2005 31/01/1995 27.80 Page 2 of 5 Permit: AWS090204 Owner: Murphy -Brown LLC Facility Number: Inspection Date: 02/24/23 Inspection Type: Compliance Inspection Reason for Visit: 090204 Routine Discharges & Stream Impacts Yes No NA NE 1. Is any discharge observed from any part of the operation? ❑ 0 ❑ ❑ Discharge originated at: Structure ❑ Application Field ❑ Other ❑ a. Was conveyance man-made? ❑ 0 ❑ ❑ b. Did discharge reach Waters of the State? (if yes, notify DWQ) ❑ 0 ❑ ❑ c. What is the estimated volume that reached waters of the State (gallons)? d. Does discharge bypass the waste management system? (if yes, notify DWQ) ❑ 0 ❑ ❑ 2. Is there evidence of a past discharge from any part of the operation? ❑ 0 ❑ ❑ 3. Were there any observable adverse impacts or potential adverse impacts to Waters of the ❑ 0 ❑ ❑ State other than from a discharge? Waste Collection, Storage & Treatment Yes No NA NE 4. Is storage capacity less than adequate? ❑ 0 ❑ ❑ If yes, is waste level into structural freeboard? ❑ 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ larc ❑ 0 ❑ ❑ trees, severe erosion, seepage, etc.)? 6. Are there structures on -site that are not properly addressed and/or managed through a ❑ ❑ ❑ waste management or closure plan? 7. Do any of the structures need maintenance or improvement? ❑ ❑ ❑ 8. Do any of the structures lack adequate markers as required by the permit? (Not applicablE ❑ 0 ❑ ❑ to roofed pits, dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require ❑ ❑ ❑ maintenance or improvement? Waste Application Yes No NA NE 10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ 0 ❑ ❑ maintenance or improvement? 11. Is there evidence of incorrect application? ❑ 0 ❑ ❑ If yes, check the appropriate box below. Excessive Ponding? ❑ Hydraulic Overload? ❑ Frozen Ground? ❑ Heavy metals (Cu, Zn, etc)? ❑ PAN? ❑ Is PAN > 10%/10 lbs.? ❑ Total Phosphorus? ❑ Failure to incorporate manure/sludge into bare soil? ❑ Outside of acceptable crop window? ❑ Evidence of wind drift? Application outside of application area? ❑ Page 3 of 5 Permit: AWS090204 Owner: Murphy -Brown LLC Inspection Date: 02/24/23 Inspection Type: Compliance Inspection Facility Number: 090204 Reason for Visit: Routine Waste Application Yes No NA NE Crop Type 1 Coastal Bermuda Grass w/ Rye Overseed Crop Type 2 Corn, Wheat, Soybeans Crop Type 3 Small Grain Cover Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Torhunta mucky sandy loam Soil Type 2 Autryville loamy sand, 0 to 3% slopes Soil Type 3 Ocilla loamy sand Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste ❑ 0 ❑ ❑ Management Plan(CAWMP)? 15. Does the receiving crop and/or land application site need improvement? ❑ 0 ❑ ❑ 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre ❑ 0 ❑ ❑ determination? 17. Does the facility lack adequate acreage for land application? ❑ 0 ❑ ❑ 18. Is there a lack of properly operating waste application equipment? ❑ 0 ❑ ❑ Records and Documents Yes No NA NE 19. Did the facility fail to have Certificate of Coverage and Permit readily available? ❑ 0 ❑ ❑ 20. Does the facility fail to have all components of the CAWMP readily available? ❑ 0 ❑ ❑ If yes, check the appropriate box below. WUP? ❑ Checklists? ❑ Design? ❑ Maps? ❑ Lease Agreements? ❑ Other? ❑ If Other, please specify 21. Does record keeping need improvement? ❑ 0 ❑ ❑ If yes, check the appropriate box below. Waste Application? ❑ Weekly Freeboard? ❑ Waste Analysis? ❑ Soil analysis? ❑ Waste Transfers? ❑ Weather code? ❑ Rainfall? ❑ Page 4 of 5 Permit: AWS090204 Inspection Date: 02/24/23 Owner: Murphy -Brown LLC Facility Number: 090204 Inspection Type: Compliance Inspection Reason for Visit: Routine Records and Documents Stocking? Crop yields? 120 Minute inspections? Monthly and 1" Rainfall Inspections Sludge Survey 22. Did the facility fail to install and maintain a rain gauge? 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipmen (NPDES only)? 24. Did the facility fail to calibrate waste application equipment as required by the permit? 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check th appropriate box(es) below: Failure to complete annual sludge survey Failure to develop a POA for sludge levels Non -compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance: 26. Did the facility fail to provide documentation of an actively certified operator in charge? 27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification? f14her 1-1— 28. Did the facility fail to properly dispose of dead animals within 24 hours and/or document and report mortality rates that exceed normal rates? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify regional DWQ of emergency situations as required by Permit (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below. Application Field ❑ #1 10-24-2023 ❑■❑❑ Yes No NA NE EJ 1#10-24-2023 ❑■❑❑ ❑■❑❑ W__ K1_ \IA I.IC Lagoon / Storage Pond Other If Other, please specify 32. Were any additional problems noted which cause non-compliance of the Permit or CAW M P? 33. Did the Reviewer/Inspector fail to discuss review/inspection with on -site representative? 34. Does the facility require a follow-up visit by same agency? ❑ ■ ❑ ❑ ❑■❑❑ ❑■❑❑ ❑■❑❑ ❑■❑❑ Page 5 of 5