HomeMy WebLinkAbout090031_routine_202302230 Division of Water Resources
❑ Division of Soil and Water Conservation
❑ Other Agency
Facility Number: 090031 Facility Status: Active Permit: AWS090031 ❑ Denied Access
Inspection Type: Compliance Inspection
Reason for Visit: Routine
Date of Visit: 02/23/2023 Entry Time: 09:00 am
Farm Name: Edge Farm / Farm 74451
Owner: Murphy -Brown LLC
Mailing Address: PO Box 487
Physical Address: Sr 1331 1888 Braxton Edge Rd
Inactive Or Closed Date:
County: Bladen Region: Fayetteville
Exit Time: 12:00 pm Incident #:
Owner Email:
Phone: 910-296-1800
Warsaw NC 283980487
E Fayetteville NC 28301
Facility Status: 0 Compliant ❑ Not Compliant Integrator: Murphy -Brown LLC
Location of Farm: Latitude: 34' 48' 16" Longitude: 78' 37' 03"
From caution light in Garland, take US 701 S 2 blocks and turn Rt. onto SR 1200 W toward Bladen Co. continue on SR 1528 to
stop sign at NC 210 intersection turn Rt. onto NC 210 for 0.1 mile turn Lt. onto SR 1002 for 6.9 miles continue on 1002 for anot
Question Areas:
Dischrge & Stream Impacts Waste Col, Stor, & Treat Waste Application
Records and Documents Other Issues
Certified Operator: William Victor Sutton
Secondary OIC(s):
Operator Certification Number: 26076
On -Site Representative(s): Name Title Phone
24 hour contact name Mike Cudd
On -site representative Mike Cudd
Primary Inspector:
Inspector Signature:
Secondary Inspector(s):
Steve Guyton
Phone: 910-433-3300
Date:
Inspection Summary:
Farm is closed no hogs
They are bringing waste in from farm 09-129 and applying onto fields.
bermuda has been overseeded.
Page 1 of 5
Permit: AWS090031 Owner: Murphy -Brown LLC Facility Number: 090031
Inspection Date: 02/23/23 Inspection Type: Compliance Inspection Reason for Visit: Routine
Regulated Operations
Design Capacity Current promotions
Swine
Swine - Feeder to Finish 9,604 I 0
Total Design Capacity: 9,604
Total SSLW: 1,296,540
Waste Structures
Effective Built Closed Designated Observed
Type Identifier Date Date Date Freeboard Freeboard
Lagoon
7442
11 /07/2005
19.50
Lagoon
74421
11 /07/2005
19.50
Lagoon
74451-1
07/29/2005
19.32
45.00
Lagoon
74451-2
07/29/2005
19.56
84.00
Lagoon
DEPOT
07/29/2005
49.00
Lagoon
LAGOON A
06/07/2006
19.50
Lagoon
LAGOO N B
1 06/07/2006
1 19.50
Page 2 of 5
Permit: AWS090031 Owner: Murphy -Brown LLC Facility Number:
Inspection Date: 02/23/23 Inspection Type: Compliance Inspection Reason for Visit:
090031
Routine
Discharges & Stream Impacts
Yes
No NA NE
1. Is any discharge observed from any part of the operation?
❑
0 ❑
❑
Discharge originated at:
Structure
❑
Application Field
❑
Other
❑
a. Was conveyance man-made?
❑
0 ❑
❑
b. Did discharge reach Waters of the State? (if yes, notify DWQ)
❑
0 ❑
❑
c. What is the estimated volume that reached waters of the State (gallons)?
d. Does discharge bypass the waste management system? (if yes, notify DWQ)
❑
0 ❑
❑
2. Is there evidence of a past discharge from any part of the operation?
❑
0 ❑
❑
3. Were there any observable adverse impacts or potential adverse impacts to Waters of the
❑
0 ❑
❑
State other than from a discharge?
Waste Collection, Storage & Treatment
Yes
No NA NE
4. Is storage capacity less than adequate?
❑
0 ❑
❑
If yes, is waste level into structural freeboard?
❑
5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ larc
❑
0 ❑
❑
trees, severe erosion, seepage, etc.)?
6. Are there structures on -site that are not properly addressed and/or managed through a
❑
❑
❑
waste management or closure plan?
7. Do any of the structures need maintenance or improvement?
❑
❑
❑
8. Do any of the structures lack adequate markers as required by the permit? (Not applicablE
❑
0 ❑
❑
to roofed pits, dry stacks and/or wet stacks)
9. Does any part of the waste management system other than the waste structures require
❑
❑
❑
maintenance or improvement?
Waste Application
Yes No NA NE
10. Are there any required buffers, setbacks, or compliance alternatives that need
❑ 0 ❑ ❑
maintenance or improvement?
11. Is there evidence of incorrect application?
❑ 0 ❑ ❑
If yes, check the appropriate box below.
Excessive Ponding?
❑
Hydraulic Overload?
❑
Frozen Ground?
❑
Heavy metals (Cu, Zn, etc)?
❑
PAN?
❑
Is PAN > 10%/10 lbs.?
❑
Total Phosphorus?
❑
Failure to incorporate manure/sludge into bare soil?
❑
Outside of acceptable crop window?
❑
Evidence of wind drift?
❑
Application outside of application area?
❑
Page 3 of 5
Permit: AWS090031 Owner: Murphy -Brown LLC
Facility Number: 090031
Inspection Date: 02/23/23 Inspection Type: Compliance Inspection
Reason for Visit: Routine
Waste Application
Yes No NA NE
Crop Type 1
Coastal Bermuda Grass w/
Rye Overseed
Crop Type 2
Crop Type 3
Crop Type 4
Crop Type 5
Crop Type 6
Soil Type 1
Wakulla sand, 1 to 6%
slopes
Soil Type 2
Ocilla loamy sand
Soil Type 3
Kenansville sand, 0 to 3%
slopes
Soil Type 4
Soil Type 5
Soil Type 6
14. Do the receiving crops differ from those designated in the Certified Animal Waste
❑
0 ❑
❑
Management Plan(CAWMP)?
15. Does the receiving crop and/or land application site need improvement?
❑
0 ❑
❑
16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre
❑
0 ❑
❑
determination?
17. Does the facility lack adequate acreage for land application?
❑
0 ❑
❑
18. Is there a lack of properly operating waste application equipment?
❑
0 ❑
❑
Records and Documents
Yes
No NA NE
19. Did the facility fail to have Certificate of Coverage and Permit readily available?
❑
0 ❑
❑
20. Does the facility fail to have all components of the CAWMP readily available?
❑
0 ❑
❑
If yes, check the appropriate box below.
WUP?
❑
Checklists?
❑
Design?
❑
Maps?
❑
Lease Agreements?
❑
Other?
❑
If Other, please specify
21. Does record keeping need improvement?
❑
0 ❑
❑
If yes, check the appropriate box below.
Waste Application?
❑
Weekly Freeboard?
❑
Waste Analysis?
❑
Soil analysis?
❑
Waste Transfers?
❑
Weather code?
❑
Page 4 of 5
Permit: AWS090031
Inspection Date: 02/23/23
Owner: Murphy -Brown LLC Facility Number: 090031
Inspection Type: Compliance Inspection Reason for Visit: Routine
Records and Documents
Rainfall?
Stocking?
Crop yields?
120 Minute inspections?
Monthly and 1" Rainfall Inspections
Sludge Survey
22. Did the facility fail to install and maintain a rain gauge?
23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipmen
(NPDES only)?
24. Did the facility fail to calibrate waste application equipment as required by the permit?
25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the
appropriate box(es) below:
Failure to complete annual sludge survey
Failure to develop a POA for sludge levels
Non -compliant sludge levels in any lagoon
List structure(s) and date of first survey indicating non-compliance:
26. Did the facility fail to provide documentation of an actively certified operator in charge?
27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification?
Otherlssues
28. Did the facility fail to properly dispose of dead animals within 24 hours and/or document
and report mortality rates that exceed normal rates?
29. At the time of the inspection did the facility pose an odor or air quality concern? If yes,
contact a regional Air Quality representative immediately.
30. Did the facility fail to notify regional DWQ of emergency situations as required by Permit
(i.e., discharge, freeboard problems, over -application)
31. Do subsurface tile drains exist at the facility?
If yes, check the appropriate box below.
Application Field
Lagoon / Storage Pond
Other
If Other, please specify
32. Were any additional problems noted which cause non-compliance of the Permit or
CAW M P?
33. Did the Reviewer/Inspector fail to discuss review/inspection with on -site representative?
34. Does the facility require a follow-up visit by same agency?
Yes No NA NE
EJ
❑■❑❑
74451 5-31-2022
❑■❑❑
❑■❑❑
Yes No NA NE
❑■❑❑
❑■❑❑
❑■❑❑
❑■❑❑
Page 5 of 5