Loading...
HomeMy WebLinkAboutNC0066028_Wasteload Allocation_19920109NPDES WASTE LOAD ALLOCATION PERMIT NO.: NCO066028 PERMITTEE NAME: Town of Lansing FACILITY NAME: keo. of LAN610& W1rP Facility Status: Existing Permit Status: Renewal Major Pipe No.: 001 Design Capacity: Minor q 0.050 MGD Domestic (% of Flow): Industrial (% of Flow): Comments: 100 % STREAM INDEX: 10-2-21-(7) RECEIVING STREAM: Big Horse Creek Class: C Sub -Basin: 05-07-02 Reference USGS Quad: B 12NE, Warrensville (please attach) County: Ashe Regional Office: Winston-Salem Regional Office Previous Exp. Date: 7/31/91 Treatment Plant Class: ? Classification changes within three miles: > 3mi. Requested by: Sha Jule nklin Date: 6/14/91 Prepared by: Date: Reviewed b Date: 1 3 a' 1/9/yL Modeler JDateRec. I # h",a (@t,k t bz 6 Drainage Area (mil ) S. _5 Avg. Streamflow (cfs): i8 7Q10 (cfs) /-3 Winter 7Q10 (cfs) 17 30Q2 (cfs) zz Toxicity Limits: IWC % Acute/Chronic Instream Monitoring: , 4. Parameters fr—ca gw+ Upstream Y Location S mac.. Jf Aar Downstream y Location f Y i�97 J Effluent Characteristics Summer Winter BOD5 (m ) 30 NH -N (mg/1) D.O. (mg/1) � TSS (mg/1) 30 F. Col. (/100 ml) PH (SU) 6 l �rnair 4 Comments: i WARRENSVILLE QUADRANGLE g `yG NORTH CAROLINA—ASHE CO. 7.5 MINUTE SERIES (TOPOGRAPHIC) 00 �2'30"453 1260000 FEETI / °54 13 MlTO U.S\58 81°30' STUROILLS 4.7 MlloulA% OF LAXS/Af67 36°30' WW iP - n , Lai14�1 Q / / 2 jo f y 4039 . �o wAgkcNs V %LL-t 194 � T / \.. 4038 zz- �g r .o Zhu C f y/ o 4037 71 'Grave 1000000 / �• a �� FEET L Cem Hi f 4035 nsyllie `\ r 194 V r RECEIVE ? N.C. uu,,,. 1.110 Facility Name: NPDES No.: Type of Waste: Facility Status: Permit Status: Receiving Stream: Stream Classification: Subbasin: County: Regional Office: Requestor: Date of Request: Topo Quad: FACT SHEET FOR WASTELOAD ALLOCATION Town of I W SIP inc 92 NC006602$ 100% Domestic Existing Renewal Big Horse Creek C 050702 Ashe Winston-Salem Regional Office Shanklin 6/14/91 B12NE Request # DEC tI 6 1991 6298 wlnSton-Salem Regional Office Stream Characteristic: USGS # 0316221500 Date: 11/21/91 Drainage Area (mi2): 55.3 Summer 7Q10 (cfs): 13 Winter 7Q10 (cfs): 17 Average Flow (cfs): 88 30Q2 (cfs): 22 IWC (%): 0.64 Wasteload Allocation Summary (approach taken, correspondence with region, EPA, etc.) Facility requesting renewal of existing permit. Due to new dilution ratio for fecal coliform limit, facility should now have fecal limit. Tech Support recommends renewal of existing limits with fecal monitoring, also upstream and downstream monitoring for fecal coliform. Special Schedule Requirements and additional comments from Reviewers1: Recommended by: ;���.Date: 11/26/91 _ Reviewed by Instream Assessment: Regional Supervisor: Permits & Engineerin RETURN TO TECHNICAL SERVICES BY: DEC 31 1"1 i/ CONVENTIONAL PARAMETERS Existine Limi Monthly Average Summer Winter Wasteflow (MGD): 0.050 BODS (mg4): 30 NH3N (mg/1): nr DO (mg/1): nr TSS (mg/1): 30 Fecal Col. (/100 ml): or pH (SU): or Residual Chlorine (µg/1): Oil & Grease (mg/1): TP (mg/1): TN (mg/1): Recommended Limi Monthly Average Summer Winter Wasteflow (MGD): 0.050 (mg/1): 0 NH3N /1): nr DO (mg/1): nr TSS (mg/1): 30 Fecal Col. V100 ml): monitor pH (SU): nr Residual Chlorine (µgh): Oil & Grease (mg/1): TP (mg/1): TN (mg/1): Limits Changes Due To: Change in 7Q10 data Change in stream classification Relocation of discharge Change in wasteflow Other (onsite toxicity study, interaction, etc.) Instream data New regulations/standards/procedures New facility information WQ or EL WQ Q N 113 Al Parameter(s) Affected Fecal Coliform (explanation of any modifications to past modeling analysis including new flows, rates, field data, interacting discharges) _X_ Parameter(s) are water quality limited. For some parameters, the available load capacity of the immediate receiving water will be consumed. This may affect future water quality based effluent limitations for additional dischargers within this portion of the watershed •j No parameters are water quality limited, but this discharge may affect future allocations. a ' 3 INSTREAM MONITORING REQUIREMENTS Upstream Location: 50 ft. upstream of discharge Downstream Location: At State Road 1347 Parameters: Fecal Coliform Special instream monitoring locations or monitoring frequencies: MISCELLANEOUS INFORMATION & SPECIAL CONDITIONS Adequacy of Existing Treatment Has the facility demonstrated the ability to meet the proposed new limits with existing treatment facilities? Yes No If no, which parameters cannot be met? Would a "phasing in" of the new limits be appropriate? Yes No If yes, please provide a schedule (and basis for that schedule) with the regional office recommendations: If no, why not? Wasteload sent to EPA? (Major) N (Y or N) (If yes, then attach schematic, toxics spreadsheet, copy of model, or, if not modeled, then old assumptions that were made, and description of how it fits into basinwide plan) Additional Information attached? (Y or N) If yes, explain with attachments. OSa7o z. 0 7 7S it- d�rJC. [[✓WJY.e.G*r /w.. r �' _ �4� � / /yam-- aJ/ L✓S/"� �_..% > 12 town of lansing wwtp AMMONIA ANALYSIS 7Q10: 12.0000 cfs NH3 Effl. Conc: 0.0000 mg/l AL (1/1.8 mg/1) : 1000.00 ug/l Upstream NH3 Conc.: 220.0000 ug/l Design Flow: 0.0500 MGD Predicted NH3 Downstream: 218.59 ug/l 0.218588 mg/1 NH3 Limit: 121774.1 ug/1 121.7741 mg/1 J town of lansing wwtp CHLORINE ANALYSIS 7Q10: 12.0000 cfs CL2 Effl. Conc: 0.0000 mg/l AL (17/19 ug/1) : 17.0000 ug/l Upstream CL2 Conc.: 0.0000 ug/l Design Flow: 0.0500 MGD Predicted C12 Downstream: 0.00 ug/l 0 mg/l CL2 Limit: 2649.258 ug/l 2.649258 mg/l