Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
800010_Inspection_20230517
Division of Water Resources Facility Number ®- O Division of Soil and Water Conservation O Other Agency Type of Visit *Compliance Inspection 0 Operation Review O Structure Evaluation O'Technical Assistance Reason for Visit O Routine O Complaint O Follow-up O Referral O Emergency O Other O Denied Access Date of Visit: -19 • Z Arrival Time: 12W Departure Time: I $w County: Qc" . Farm Name: V)Crgy„+ grp*ra ]76: Owner Email: Owner Name: Mailing Address: Physical Address: Facility Contact: Onsite Representative: Certified Operator: Back-up Operator: Location of Farm: Phone: Title: Phone: Integrator: Certification Number: Certification Number: Latitude: Longitude: Design Current Design Current Swine Capacity Pop. Wet Poultry Capacity Pop. Wean to Finish Layer Wean to Feeder I Nan -La yer Feeder to Finish Farrow to Wean Farrow to Feeder Farrow to Finish Gilts Boars Design Current Dry Poultry Capacity Pop. Layers Non -Layers Pullets Turkeys Other Turkey Pouets Other Diacharees and Stream house s 1. Is any discharge observed from any part of the operation? Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: _ a. Was the conveyance man-made? b. Did the discharge reach waters of the State? (If yes, notify DWR) c. What is the estimated volume that reached waters of the State (gallons)? _ d. Does the discharge bypass the waste management system? (If yes, notify DWR) 2. Is there evidence of a past discharge from any part of the operation? 3. Were there any observable adverse impacts or potential adverse impacts to the waters of the Sure other than from a discharge? Region: M20 Design Current Cattle Capacity Pop. Darry Cow Dairy Calf Dairy Heifer /b 1 Dry Cow Non -Dairy Beef Stocker Beef Feeder Bret Brood Co, ❑ Yes ® No ❑ NA ❑ NE ❑ Yes ❑ No ❑ NA ❑ NE [—]Yes [—]No [:]NA [—]NE [:]Yes [:]No [:]NA ❑ NE ❑ Yes ® No ❑ NA ❑ NE ❑ Yes No ❑ NA ❑ NE Page 1 of 51122020 Continued Facill Number: I jDate of Inspection: Waste Collection & Treatment 4. Is storage capacity (structural plus storm storage plus heavy minfall) less than adequate? a. If yes, is waste level into the structural freeboard? Structure 1 Structure 2 Structure 3 Structure 4 Identifier: Q,,a I I- PW4 3 SpillwayR: Yes cs OJD Designed Freeboard (in): K V_ 1% Observed Freeboard (in): 0 24- 5. Are there any immediate threats to the integrity of any of the structures observed? (i.e., large trees, severe erosion, seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a waste management or closure plan? ❑ Yes ® No ❑ NA ❑ NE ❑ Yes ❑ No ❑ NA ❑ NE Structure 5 Structure 6 ❑ Yes ® No ❑ NA ❑ NE ❑ Yes ®No ❑ NA ❑ NE If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental threat, notify DWR 7. Do any of the structures need maintenance or improvement? ❑ Yes q No ❑ NA ❑ NE 8. Do any of the structures lack adequate markers as required by the permit? ❑ Yes ® No ❑ NA ❑ NE (not applicable to roofed pits, dry stacks, and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require ❑ Yes ® No ❑ NA ❑ NE maintenance or improvement? Waste Application 10. Am there any required buffers, setbacks, or compliance alternatives that need ❑ Yes ® No ❑ NA ❑ NE maintenance or improvement? 11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Yes ® No ❑ NA ❑FIE ❑ Excessive Pending ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.) ❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area 12. Crop Type(s): S` Ire., 13. Soil Type(s): 14. Do the receiving crops differ from those designated in the CAWMP? ❑ Yes ®No ❑ NA ❑ NE 15. Does the receiving crop and/or land application site need improvement? ❑ Yes K No ❑ NA ❑ NE 16. Did the facility fail to secure and/or operate per the iffigation design or wettable ❑ Yes [N No ❑ NA ❑ NE acres determination? 17. Does the facility lack adequate acreage for land application? ❑ Yes ® No ❑ NA ❑ NE 18. Is them a lack of properly operating waste application equipment? ❑ Yes [4 No ❑ NA ❑ NE Reauired Records & Documents 19. Did the facility fail to have the Certificate of Coverage & Permit readily available? ❑ Yes ® No ❑ NA ❑ NE 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check ❑ Yes ® No ❑ NA ❑ NE the appropriate box. ❑WUP ❑Checklists ❑Design ❑Maps ❑ Lease Agreements ❑Other: 21. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Yes Co No ❑ NA ❑ NE ❑ Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Waste Transfers ❑ Weather Code ❑ Rainfall ❑ Stocking ❑ Crop Yield ❑ 120 Minute Inspections ❑ Monthly and V Rainfall Inspections ❑ Sludge Survey 22. Did the facility fail to install and maintain a rain gauge? ❑ Yes ® No ❑ NA ❑ NE 23. If selected, did the facility fail to install and maintain minbreakers on irrigation equipment? ❑ Yes ❑ No Lra-fNA ❑ NE Page 2 of 3 511212020 Continued [Facility Number: I jDate of Inspection: 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ Yes ®No 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check ❑ Yes P No the appropriate boxes) below. ❑ Failure to complete annual sludge survey ❑Failure to develop a POA for sludge levels ❑ Non -compliant sludge levels in any lagoon List structure(s) and date of first survey indicating noncompliance: 26. Did the facility fail to provide documentation of an actively certified operator in charge? ❑ Yes ® No 27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? ❑ Yes [3 No Other Issues 29. Did the facility fail to properly dispose of dead animals with 24 hours and/or document ❑ Yes © No and report mortality rates that were higher than normal? 29. At the time of the inspection did the facility pose an odor or air quality concern? ❑ Yes ® No If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the ❑ Yes C@ No permit? (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below. ❑ Yes ® No ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? ❑ Yes ®No 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative? ❑ Yes ® No 34. Does the facility require a follow-up visit by the same agency? ❑ Yes No ❑ NA ❑ NE ❑ NA ❑ NE ❑ NA ❑ NE ❑ NA ❑ NE ❑ NA ❑ NE ❑ NA ❑ NE ❑ NA ❑ NE DNA ONE ❑ NA ❑ NE ❑ NA ❑ NE ❑ NA ❑ NE rymenta (refer to question 4): Explain any YES answers and/or any additional recommendations or any other comments. (facility to better explain situations (use additional pages as necessary). Reviewer/Inspector Name: T Reviewer/Inspector Signature: Page 3 of Phone: Date: 5'-P -73 51122021)