Loading...
HomeMy WebLinkAboutNC0057193_Permit Issuance_20071008NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross, Jr., Secretary Coleen H. Sullins, Director October 8, 2007 Mr. Robert Cooperrider Nantahala Outdoor Center 13077 U.S. Hwy 19 West Bryson City, NC 28540 Subject: Issuance of NPDES Permit NCO057193 Nantahala Outdoor Center WWTP Swain County Dear Mr. Cooperrider: Division personnel have reviewed and approved your application for renewal of the subject permit. Accordingly, we are forwarding the attached NPDES discharge permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated May 9, 1994 (or as subsequently amended). This final permit includes no major changes from the draft permit sent to you on August 15, 2007. If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings (6714 Mail Service Center, Raleigh, North Carolina 27699-6714). Unless such demand is made, this decision shall be final and binding. Please note that this permit is not transferable except after notice to the Division. The Division may require modification or revocation and reissuance of the permit. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, the Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Charles Weaver at telephone number (919) 733-5083, extension 511. Sincerely, el" s� Coleen H. Sullins cc: Central Files Asheville Regional Office/Surface Water Protection NPDES Unit 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 One 512 North Salisbury Street, Raleigh, North Carolina 27604 NorthCarolina Phone: 919 733-5083 / FAX 919 733-0719 / Internet: www.ncwaterquality.org Awmnally An Equal Opportunity/Affirmative Action Employer- 50% Recycled/10% Post Consumer Paper Permit NCO057193 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY PERMIT TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, the Nantahala Outdoor Center is hereby authorized to discharge wastewater from a facility located at the Nantahala Outdoor Center WWTP U.S. Highway 19 Wesser. Swain County to receiving waters designated as the Nantahala River in subbasin 04-04-02 of the Little Tennessee River Basin in accordance with effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This permit shall become effective November 1, 2007. This permit and authorization to discharge shall expire at midnight on October 31, 2012. Signed this day October 8, 2007. Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Quad: Wesser, N.C. N C O 0 5 7 1 g 3 Stream Class: B-Trout Subbasin: 40402 Nantahala Outdoor Center Latitude: 35°19'59" WWTP Longitude: 83°35'30" Receiving Stream: Nantahala River vO, r* �s k 'i Facility x, Location �,. , <.- �w r North SCALE 1:214000 Permit NCO057193 A. (1) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS During the period beginning on the effective date of this permit and lasting until expiration, the Permittee is authorized to discharge from outfall 001. Such discharges shall be limited and monitored by the Permittee as specified below: PARAMETER LIMITS}, »MONITOR ING REQUIREMENTS = Monthl Dai( Measurement Sample Type Sarn le Location x ` ',,Maximum Frequency x �. Average R . 3 w Flow 0.040 MGD Continuous Recording Influent or Effluent BOD, 5-day (20°C) 30.0 mg/L 45.0 mg/L Weekly Composite Effluent Total Suspended Solids 30.0 mg/L 45.0 mg/L Weekly Composite Effluent NH3 as N 2/Month Composite Effluent Fecal Coliform (geometric mean) 200 / 100 ml 400 / 100 ml Weekly Grab Effluent Total Residual Chlorines 17 pg/L 2/Week Grab Effluent Temperature (°C) Weekly Grab Effluent pH > 6.0 and < 9.0 standard units 2/Month Grab Effluent Footnotes: 1. Limit and monitoring requirements apply only if chlorine is added for disinfection. There shall be no discharge of floating solids or visible foam in other than trace amounts. W THE SMOKY MOUNTAIN TIMES Bryson City, North Carolina PUBLIC NOTICE other supporting information, on file NC0057193: -A la :Outdoor u' STATE OF NORTH- CAROLINA used to determine conditions pres- Center ..(13077 U.S. Highway 19 ENVIRONMENTAL. MANAGE- . ent in the draft permit are available ' West, Bryson.City, NC 28713);•has STATE OF NORTH CAF ..MENTCOMMISSION/NPDES• upon request and payment of the applied for renewal of its per to COUNTY OF SWAIN UNIT costs' of rePfoduction. Mail. com discharge treated domestic waste= " 1617�MAIL SERVICI� CENTER ments and/or requests for informa- .. water to the Nantahala River in the RALEIGH, NC 27699-1617 tion to the' NC':Divis'ion.79F Water, .Little Tennessee _River Basm NOTIFICATON OF INTENT TO : Quality at the above address or call. ; Currently total, residual` chlorine is I, PETS LAWSON, Edi' -ISSUE'ANODES WASTEWATER_,; Ms. Frances'Caridelaria (919) 733= water. qualitylimited,1hisdischarge PERMIT 5083, extension 520 `at 'the Poinf may: affect future allocations. inAhis newspaper published in Sv Onjh6 basis of thorough,staff Source::Branch. Please inclUde.the portion of the Nantahala River with STATUTES G.S. 1-55 review. 'and application of NC NPDES permit number (attached) session General Assembly; General`Statute 143.21, Public,law in any communication 'Interested•`"WESE, Inc d*Nantahala Village., advertisement of 92-500 and other lawful. standards persons may aisa;'wisit the Division; Resort &Spat{9400 'O S highway and: regulations, the: North Carolina .. of Water Quality at512 N. Salisbury ._.,19 . West, Bryson City, NC 28713) ; Environmental Management w Street, Raleigh,, NC 276041;148 Chas applied for renewal ofp�ermlt` � ► � I'VIr4/sJ Commission"proposes: •to issue a' t etween'the hours of 8:00 a m. and . NCOQ37737 'for its Nantahala' National Pollutant Discharge 5.00 p.m. to review information:. on. Wlllag, Swain "County Elimination . System (NPDES) file f This.facility =dlschar es,,treated 9. was duly published in the of wastewater discharge permit.to the ri;•�1 <T.r ? ;��domestic :wastewater to an'. cQnSeetltiv Neek(,8'S, beglnr persori(s) listed below effective: 45 the National Park Service (107' °t9nnamed tributary to`ttie:Nantanda' II days from the publish date of this .,Park ' Headquarters Road;;. ,River.10 the.Little Tennessee Rivet notice. Gatlin burn TN 37738) has a lid Written; comments. regarding, the proposed permit will be accept ed.until 3.0 days;after.the publish date ofi,this:.notice,.All",comments P to Lawson, received prior to that'date are• con (Owner, partner, Publisher sidered:n the final..determinations regarding the proposed' permit. The affidavit) Director,of the. NC Division of Water Quality may decide to ,hold9 public. meetingfor. the proposed_ permit; should the Division receive a signif- icah degree of public interest. d, Copies of the draft' permit an pp a asin urren y e%, coliform, •:for renewal of perm t NCQ025101 ammonia nitrogen and total residual', for its ;Smokemont�Campgrdund; chlorine are, water':quality.limited: WWTP fi Swain County. This per . This discharge may affect future' miffed facility discharges;, treated:; allocations in'_ this' portion:'' of the domestic. wastewater' to the `Nantahala River ; r Oconaluftee River in the, Little;., 04 1tc No 929 'Ji Tenn essee.River`Basin Currerttly;i ` total'residual chlorine is water.qual- ity limited. 'This discharge :may"w! affect future allocations in this por= tion of the Oconaiuftee River. Swor to (or .affirmed) and subscribed before me this the N � day of cf , 20IDI, o Off i 1 Signature of Notary JULIA =C&rdina N N Swain CaJulia J. Thompson Nota Public MY Cortrriiati2012 Notary Notary's printed or typed name My commission expires: February 5, 2012 contact for NC Dept, of Water Quality Subject: New contact for NC Dept, of Water Quality From: Lance Ingram <lance.ingram@noc.com> Date: Tue, 11 Sep 2007 15:52:40 -0400 To: bob.guerra@ncmail.net Lance Ingram 09/11/2007 03:44 PM To: bobguerra@ncmail.net , cc: Lee Leibfarth/Wesser/NC/NOC bcc: Lance Ingram/Wesser/NC/NOC Subject: New contact for NC Dept, of Water Quality Hi Bob: Please find the info below to replace Larry Pitt as our contact person with you. Mr Pitt no longer works at the Outdoor Center and Mr.Leibfarth will be signing our DMR's for now on. Mr.Lee Leibfarth, VP Operations Nantahala Outdoor Center 13077 Hwy-19 West Bryson City NC 28713 828.488.2176 ext.101 Regards, Lance Ingram, ORC 1 of 1 9/12/2007 7:43 AM NPDES APPLICATION - FORM D For privately owned treatment systems treating ' 100% domestic wastewaters <1.0 MGD Mail the complete application to: N. C. Department of Eavironment.and Natural Resources Division of Water Quality./ NPDES Unit 1617, Mail Service Center, Raleigh, NC- 27699-1617 NPDES Permit INCOO 15 Please print or type. 1. Contact Information: Owner Name 5u_T-Tdt-i + Q=-- (2> Facility Name Mailing Address City State / Zip Code Telephone Number 02S 4M - 2-1-7 S Fax Number 828) 4-cc?)'& - 24-1 �- e-mail Address �AC�L� �, NOS 2. Location of facility producing c Check here if same address as above Street Address or State. Road - . City State / Zip Code County 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Ier�N-I'�►1 �►1�t DVTn rxUfy. Mailing Address City State / Zip Code SOKIIA CAROU K A 2-e-+13 Telephone Number 4b& - 2-17 J Fax Number �-- HA tL AC00P —==!5-s f�►N�C �h1l°a Ali � t�UC.Cc�1V1 1 of 3 Form-D 4/05 NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD 4. Description of wastewater: Facility Generating Wastewater(check all that apply): Industrial ❑ Number of Employees Commercial [ Number of Employees Zoo Residential ❑ Number of Homes School. ❑ Number of Students/Staff Other ❑ Explain: Describe the source(s) of wastewater (example: subdivision, mobile home park, shopping centers, restaurants, etc.): VACjX i oN tZa !sJM'T % 7WZ3 teGz-S ALj-zL1,r-rrS Loo& 1 tV eA Population served: ISO 5. Type of collection system [Separate (sanitarysewer only) ❑ Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points Qtj E Outfall Identification number(s) p®l - Is the outfall equipped with a diffuser? :0' Yes No , ?. Name of receiving stream(s). (Provide a map showing the exact location of each outfall) 8. Frequency of Discharge:. [Continuous ❑ Intermittent If intermittent: Days per week discharge occurs: Duration: ' 9. Describe the treatment system List all installed components, including capacities, provide design removal for BOD, TSS, nitrogen and phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet of paper. 2 of 3 Form-D 4/05 NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD 10 Flow Information: Treatment Plant Design flow 1 %L) OMGD Annual Average daily flow Oo O 106GI) (for the previous 3 years) Maximum daily flow da O , (OMGD (for the previous 3 years) 11. Is this facility located on Indian country? ❑ Yes [ No 12. Effluent Data Provide data for the parameters listed.- Fecal Coliform, Temperature and pH shall be grab samples, for all other parameters 24-hour composite sampling shall be used. If more than one analysis is reported, report daily maximum and monthly dverage. If only one analysis is reported, report as daily maximum. Parameter Daily Maximum Monthly Average Units of Measurement Biochemical Oxygen Demand (BOD5) 4�� J 1 [, 30.i� - �►�► l YVL L Fecal Coliform 400 100 wt, 1 Total Suspended Solids 3 0 Temperature (Summer) ,YV A Ir--perature. (Winter) pH 13. List all permits, construction approvals and/or applications: Type Permit Number Type - Permit Number Hazardous Waste (RCRA) NESHAPS (CAA) -----UICSDWA -._ -=- -- — -- _._..--.. ( ) - - — ---._._.._.:._—Ocean Dumping (MPRSA) - NPDES N L a a -7 l g 3 Dredge or fill (Section 404 or CWA) PSD (CAA) Other Non -attainment program (CAA) 14�--APPLICANT CERTIFICATION — I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed name of Person ---Title of APAc&nt . _. __._ -- .... - —-._.._..---_..— ...Date - North Carolina General Statute 143-215.6 (b)(2) states: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowly renders inaccurate any recording or monitoring device or method required to be operated. or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) 3 of 3 Form-D 4/05 SEQUENCING BATCH REACTOR MIXAIR SYSTEM DESIGN: Low Load NANTAHALA OUTDOOR CENTER WWTP DUAL BASIN SBR DATE: August 19, 1998- PRT? P'AR1Zi1 RV The enclosed information is based upon preliminary data which we have received from you. There may be factors unknown to us which would alter the -enclosed recommendation. These -recommendations are based on models and assumptions widely . used in the industry. While we attempt'to.keep these current, Aqua -Aerobic Systems; -Inc. assumes no responsibility for. their validity or any risks associated with their use. Also, because of the various factors stated above, -Aqua -Aerobic Systems, Inc. assumes no responsibility for any liability resulting from any use made by you of the enclosed recommendations. Copyright 1995, Aqua Aerobic Systems, Inc. 6 NANTAHALA .08-19-1998 j.. The following- desi-gn -notes app- y--to the Pre=SBR treatment system: Pre-SBR treatment system unknown. pH will range from 6.5 to 8.5 as influent to the-SBR The following design notes apply to the SBR System: FLOW: - Assume flow is received overa 24 hour period. - A maximum daily hydraulic flow of 2.00 .times the average design has been given. Maximum daily flow has been interpreted as a flow condition which does not represent an increased organic load. PROCESS/SITE CONDITIONS: -.An elevation of 1750 feet has been utilized. DESIGN LOADINGS: The aeration system has been designed to -provide oxygen for BOD at-1.25 lbs. 02/lb. BOD applied. - TSS and TKN influent loadings have been assumed. - The aeration system has been designed to provide oxygen for TKN at 4.60. lbs,. 02/lb. TKN applied: ANTICIPATED PERFORMANCE: The Following Design Notes Apply. -to -the Post-SBR---T-reatme-nt S-yetetv; - Post SBR treatment unknown. The Following Design Notes Apply -to the Sludge Holding .Basin: Preliminary digester sizing yields a required volume of 20,364 gallons in order to achieve,a 30 day sludge retention. time. (Basin by others) Page 1 of 2 .Aqua Aerobic Systems, Inc. NANTA RALA The Following Equipment Notes Apply: BASIN/EQUIPMENT Basin dimensions required have been provided in the design calculations. Basins are not included in the pricing and are to be supplied by others. - Assume adequate ventilation of tanks will be provided to allow for utilization of standard electrical components. - Assume gravity decant is achievable. Centerline of decant will be located 1.0 ft. below minimum water level. - Recommend a minimum of 2.0 feet freeboard for AquaCAM-D. PRICING - Price includes freight, installation supervision.and start-up supervision. - Pricing is based on our standard materials of construction and electrical components. Page 2 of 2 Aqua Aerobic Systems, Inc. JOB NAME: NANTAHALA OUTDOOR CENTER WWTP DATE: August 19, 1998 BY: RCM SBR DESIGN PARAMETERS AVG FLOW = 0..040 MGD MAX DAILY FLOW = 0.080 MGD EFFLUENT (mg/1) INFLUENT (mg/1) REQUIRED ANTICIPATED° BOD5 600 BOD5 30.0 < 30.0 -TSS 300 TSS 30.0 < 30.0 TKN 60 TKN N/R °Anticipated Effluent Prior to Filtration. F/M = 0.120 1/day MLSS = 4500 mg/l CYCLES PER BASIN: 5.0 BASIN DIMENSIONS: 2, 21 X 12 FT RECTANGULAR BASINS MAXIMUM VOLUME.=- 0.030'MG DECANT FLOW RATE = 320 GPM HIGH WATER LEVEL = 16.0 FT MAXIMUM DECANT HEIGHT =,4.2 FT LOW WATER LEVEL = 11.8 FT AVERAGE DECANT HEIGHT = 2.1 FT, HYDRAULIC RETENTION TIME AT LOW WATER LEVEL = 26.1 HOURS LBS WASTED SOLIDS/LB BOD5.= 0.56 SLUDGE FLOW RATE = 45 GPM -= -- - -- - — -- - - - --- --- - -- --- -- -- -- - - -� @ 3 minute/ cycle /basin )... - . _- SBR EQUIPMENT NUMBER SIZE AQUA-CAMDS _ 2 15.0 HP ---....- -- - (6in. _hose)---- ----- SLUDGE VALVES - 2- - - _ -4 in. Diameter INFLUENT VALVES 2" - 3'-in. Diameter CONTROL PANEL 1 Includes Motor Starters Estimated Operating Power = 20.9.BHP (415 KW-hrs/day) -- Copyright 1995, Aqua Aerobic Systems, Inc. 6 OF DESIGN FACT SHEET _....._.. . A. GIVEN OR ASSUMED ° Design Flow (Avg. 24-Hr.)----=---------------------- 0.0400 M.G.D. Maximum -Daily Flow ___________________________ 0.0800 M.G.D. ° Design Loading BODS.----------------------------------------- 600 mg/l lbs. BODS/day = 0.0400 M.G.D..x 600 ppm x 8.34 lbs./gal---- ---- 200 lbs/day TSS----------------------------------------- 300 mg/1 lbs. TSS/day = 0.0400 M.G.D. x 300 ppm x 8.34 lbs./gal-------- 100 lbs/day TKN------------------------------------.=---- 60 mg/l lbs. TKN /day = 0.0400.M.G.D. x 60 ppm x 8.34 lbs./gal---- ---- 20 lbs/day B. SITE CONDITIONS ° Elevation Above Sea Level--------------------------- 1750 feet ° Temperature of Waste: Summer Average ---------------------------- 68 F (20.0 C) -- Winter Average ------------------------.- 50-F-(1OT-0-G)- --- Ambient Temperature: Summer Average ---------------------------- 85 F (29.4 C) _-Winter Average-. =--------------------------- 30 F (-1.1 C) C. EFFLUENT CRITERIA BOD5-=-------------------------------- 30.0 mg/l. ° TSS---------------------------------- 30.0 mg/1 D. ANTICIPATED PERFORMANCE -(as monthly avg. prior to filtration) BOD5 -----< 30.0 mg/1 TSS - < 30.0 mg/l PAGE 1 6 AERATION SYSTEM A. MIXAIR AQUA -AEROBIC, INC., S.B.R. PROCESS _ DESIGN CRITERIA 1. BASIN a. Rectangular, 21 ft. by 12 ft. b. 16.0 ft. SWD at Maximum water level. C. 11.8 ft. SWD at Minimum water level. d. Normal range 11,8 ft. SWD to 13.9 ft. SWD at Design Flow. e. Minimum of 26.7 hours of retention time at.Design Flow. 2. OXYGEN a. F:M = 0.120 lb. BOD5/lb. MLSS. b. 'MLSS = 4500 ppm at low water level. C. MLVSS assumed to be 0.70 x MLSS. d. SVI = 100 ml/g after 60 minutes settling. e. 1.00 lb. 02/lb. BOD5 at Peak Conditions. f. 1.25 lb. 02/lb. BOD5 at Design Conditions. g. 4.60 lb. 02/lb. TKN Applied. NOTE: During aerobic periods assume SBR operation —using-5 cyclbs per day basin, per for a total of 10 cycles. C. AERATION REACTOR CAPACITY REQUIRED 1,668 lbs. MLSS 0.120 lbs. BOD5/lb: MLSS 2. lbs. MLSS = Volume in M.G. x MLSS concentration in ppm.x 8-.34 lbs./gal. Assume 4500 ppm MLSS. concentration.at Minimum-_SWD - --- 1,668 lbs.. MLSS Volume M.G. _ = 0.044 M.G. •4500 ppm x 8.34 5,942 cubic feet PAGE 2 6 AERATION BASINS) 1. Use 2 rectangular basins, Dimensions: 21.0 feet by r 12.0 feet by 16.0 feet SWD. 2. Actual Retention Time at Design Flow and 11.8 feet S.W.D.. 5,947 cu.ft. x 7.48 gal./cu.ft. x 24 = 26.7 hr. 40,000 gpd 3. Actual Retention Time at Maximum Flow and 16.0 feet S.W.D.. 8,088 cu.ft. x 7.48 gal./cu.ft. x 24 = 18.1 hr. 80,000 gpd E. AIR REQUIREMENTS 1. Oxygen Requirements a. 02 Required for BOD5 = 200.2 lb. BOD5 per day x 1.25 lbs. 02 per lb. BOD5 250.2 lb. 02 per day. b. 02 Required for TKN = 20.0 lb. TKN _ .... 92_,1 -l.b__O2.. per _-day-•---- .._ ....._ ---- - - C. Total 02 required = 342.3 lbs 02 per day A.O.R. d. -Actual Oxygen -Requirement ...Total 02 Required, lbs/day - - — --__ A.O.R. _ Aeration time, hrs/day 342.3 lbs 02/day 3.4 hrs cyc e x 5 cyc es da—y/b—asdh x - 2 .basin(s) 10.1 lbs/hr/Basin .PAGE 3 6 2.. Field' 02 Transfer Tate *and HP Requirements T-20 CWTR[(.Cs*9)-Cr](1.024) (a) r FTR = 9.09 Where, CWTR = Clean Water Transfer Rate at Standard Conditions (lbs 02/BHP-Hour) = 1.30 lbs 02/BHP-Hour T = Temperature of Wastewater at Design Conditions, Degrees Centigrade = 20.0 Degrees Centigrade Cs = Saturation Concentration of 02 at Design of 20.0 Degrees Centigrade and at 1,750 Feet Elevation = 8.50 mg/l 13 = Saturation Correction Coefficient = 0.95 (Typical, Assumed) Cr = Residual D.O. Concentration to be Maintained = 2.00 mg/1 a = 02 Transfer Rate Correction Coefficient = 0.85 (Typical, Assumed) - FTR = 0.74 lbs 02/BHP-Hour (Design Condition.)-. Therefore, .10.1 lbs 02/Hour/Basin HP(02 Demand) _ - - -=- - --- ----- - _---- 0__74--lbs--02/BHP-Hour .-._ = 14 BHP/Basin = 15 NPHP/Basin (Design Condition). -.Recommend: 1 - 15.0 H.P. .. Aqua-CamD Aerator(s)/Basin 3. Aerator Operating B.H.P. at Design.Condition-- 13.8 BHP/bsn x 2 basin(s) x 18.2 mix -aerate hrs/d/bsn OP. BHP = .24 hrs/day/bsn = 20.9 BHP PAGE 4 6 r . PIIAI14U .UEMAND WITH - SURF.hCE ASPIRATORS ` 1. Design for a mixing level of 456.2 BHP/MGal at maximum water level. Recommend: 1 - 15.0 H.P. Aqua Camd - per -basin to completely mix aeration basins. III SLUDGE AND DECANTER PUMP CALCULATIONS A. Sludge Flowrate 1. lbs. of sludge per day = 200 lbs. BOD5 per day x 0.56 lbs. of sludge produced per lb. of BOD5 applied = 113 lbs. 2. sludge flowrate = (lbs. sludge.per.day/sludge concentration)/8.34 _ (113/0.01)/8.34 = 1,354 GPD B. Sludge and Decanter Flowrate at Design Conditions Design Flowrate = MDF / (NB x NCB x MCT) Where: MDF = maximum daily flow for decant (0.080.MGD) or sludge waste (1,354 GPD) NB = number of basins (2) NCR - number of GyGles-per dam per basin ( 5 ) ------ - - -.. MCT = maximum cycle time _f.or, decant ^(25 min) or -_sludge- waste.-_( 3 min) 1. Sludge Flowrate at Design Conditions Sludge-Flowrate = .1, 3 54./ (.2 x 5 x 3 ) = 45' GPM 2. D_ecanter Des gn._Flowrate-at-Design Conditions ....- Decant Flowrate = 80,000/(2 x 5 x 25) = 320 GPM For gravity decanters 320 GPM would be the average flowrate. The actual flowrate would vary depending on the driving head available -at the -time---- - -- -- d. Sludge and Decanter Pump Horse Power Pump BHP = (flowrate x head) / (3960 x efficiency). 1. Sludge Pump, Gravity flow, no pump required 2. Decanter, Gravity flow, no pump required PAGE 5 6 j3 uparar-ing •b : kV.'1� , , T- Ue5.1q?1 L. JLlul L. LCJ117 Cycle Time = ADF / (NB x NCB x DFR x 60) Where: ADF = average daily flow for decant (0.040 MGD) or sludge waste (1;354 GPD) DFR = design flow rate for decanter (320 GPM) or q_udge waste (45 GPM) MOTOR LIST NUMBER SIZE TOTAL HP BHP REQ'D EQUIPMENT MOTORS NPHP INSTALLED• AT DESIGN AQUA-CAM(D) 2 15.0 30.0 20.892 2 30.0 20.892 ° OP KW-hrs/day = (20.892 BHP x 0.7457 KW/HP x 24 hrs/day)/0.90 415 KW-hrs/day Note: An overall motor efficiency of 90% is assumed. PAGE 6 _ Copyright 1995, Aqua Aerobic Systems, Inc. 6 FACT SHEET FOR EXPEDITED PERMIT RENEWALS Basic Information to determine potential for expedited permit renewal Reviewer/Date AA Permit Number NCOP 7102, Facility Name 0"a—doov CE`�/ m Basin Name/Sub-basin number 0:4 r 0 Receiving Stream 01 " 4-". 1 n Stream Classification in Permit Does permit need NH3 limits?�. Does permit need TRC limits? tt� Does permit have toxicity testing? 0 Does permit have Special Conditions? , v Does permit have instream monitoring? P Is the stream impaired (on 303(d) list)? 0 Any obvious compliance concerns? Any permit mods since lastpermit? Existing expiration date p /? / 0 % New expiration date //-Z-- New permit effective date Miscellaneous Comments YESV This is a SIMPLE EXPEDITED permit renewal (administrative renewal with no changes, or only minor changes such as TRC, NH3, name/ownership changes). Include conventional WTPs in this group. YES_ This is a MORE COMPLEX EXPEDITED permit renewal (includes Special Conditions (such as EAA, Wastewater Management Plan), 303(d) listed, toxicity testing, instream monitoring, compliance concerns, phased limits). Basin Coordinator to make case -by -case decision. YES_ This permit CANNOT RE EXPEDITED for one of the following reasons: • Major Facility (municipal/industrial) • Minor Municipals with pretreatment program • Minor Industrials subject to Fed Effluent Guidelines (lb/day limits for BOD, TSS, etc) • Limits based on reasonable potential analysis (metals, GW remediation organics) • Permitted flow > 0.5 MGD (requires full Fact Sheet) • Permits determined by Basin Coordinator to be outside expedited process TB Version 8/18/2006 (NPDES Server/Current Versions/Expedited Fact Sheet)