HomeMy WebLinkAboutNC0024872_Compliance Evaluation Inspection_20230519 (2)United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCO024872 111 121 23/05/11 I17 18 LC] I 19 I s I 20L] 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I ni I 71 I 74 79 I I I I I I I80 701 I 71 I LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 08:OOAM 23/05/11 21/10/01 Cooleemee WWTP NC Hwy 801 S Exit Time/Date Permit Expiration Date Cooleemee NC 27014 10:OOAM 23/05/11 26/06/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Timothy Lamar Smith/ORC/336-284-6680/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Tim Smith,NC Hwy 801 S Cooleemee NC 27014/ORC/336-284-6680/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenar 0 Records/Reports Self -Monitoring Progran 0 Facility Site Review Effluent/Receiving Wate Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Gary Hudson DWR/Division of Water Qua Iity/336-776-9694/ DocuSigned by: a OttIS&A, 5/18/2023 8B 22824F 6 4A6. Signa ure of anagement Q A Reviewer Agency/Office/Phone and Fax Numbers Date DocuSigned by: 5/18/202 3 L o' -T. 5,,o r EPA "4 99&4 @R +A9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NCO024872 I11 12I 23/05/11 117 18 i c i (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) *The WWTP appeared to be well operated and maintained. No discrepancies were noted during the inspection. *The permit became effective on October 1, 2021, and will expire on June 30, 2026. *Mr. Smith does a very good job with regards to keeping records. *The June 2022 eDMR was checked with the contract lab reports. No discrepancies were noted. *The mechanical bar screen is located in the main pump station on the other side of the South Yadkin River. *The aeration basin appeared to be operating properly. There is a floating mechanical aerator and a floating mixer in each of the aeration basins. *The secondary clarifier appeared to be working properly. The effluent leaving the clarifier was very clear on the day of the inspection. *The effluent pipe was located. The discharge was very clear at the time of the inspection. *The effluent flow meter was last calibrated on March 28, 2023. Page# 2 Permit: NCO024872 Inspection Date: 05/11/2023 Owner -Facility: Cooleemee WWTP Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ■ ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The WWTP appeared to be well operated and maintained. No discrepancies were noted during the inspection. Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ■ ❑ application? Is the facility as described in the permit? ■ ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ■ ❑ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: The permit became effective on October 1, 2021, and will expire on June 30, 2026. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ■ ❑ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ■ ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ❑ ❑ ■ ❑ operator on each shift? Is the ORC visitation log available and current? ■ ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ■ ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility ■ ❑ ❑ ❑ classification? Page# 3 Permit: NCO024872 Owner -Facility: Cooleemee WWTP Inspection Date: 05/11/2023 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? 0 ❑ ❑ ❑ Comment: Mr. Smith does a very good mob with regards to keeping records. The June 2022 eDMR was checked with the contract lab reports. No discrepancies were noted. Bar Screens Type of bar screen Yes No NA NE a.Manual ❑ b.Mechanical Are the bars adequately screening debris? ■ ❑ ❑ ❑ Is the screen free of excessive debris? ■ ❑ ❑ ❑ Is disposal of screening in compliance? 0 ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: The mechanical bar screen is located in the main pump station on the other side of the South Yadkin River. Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Surface Is the basin free of dead spots? 0 ❑ ❑ ❑ Are surface aerators and mixers operational? 0 ❑ ❑ ❑ Are the diffusers operational? ❑ ❑ ■ ❑ Is the foam the proper color for the treatment process? ■ ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? 0 ❑ ❑ ❑ Is the DO level acceptable? ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/1) ❑ ❑ ❑ ■ Comment: The aeration basin appeared to be operating properly. There is a floatinq mechanical aerator and a floating mixer in each of the aeration basins. Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? 0 ❑ ❑ ❑ Are weirs level? 0 ❑ ❑ ❑ Page# 4 Permit: NCO024872 Inspection Date: 05/11/2023 Owner -Facility: Cooleemee WWTP Inspection Type: Compliance Evaluation Secondary Clarifier Yes No NA NE Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting? 0 ❑ ❑ ❑ Is scum removal adequate? ■ ❑ ❑ ❑ Is the site free of excessive floating sludge? 0 ❑ ❑ ❑ Is the drive unit operational? 0 ❑ ❑ ❑ Is the return rate acceptable (low turbulence)? 0 ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? ■ ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) ❑ ❑ ❑ Comment: The secondary clarifier appeared to be working properly. The effluent leaving the clarifier was very clear on the day of the inspection. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ ❑ ❑ Comment: The effluent pipe was located. The discharge was very clear at the time of the inspection. The effluent flow meter was last calibrated on March 28, 2023. Page# 5