Loading...
HomeMy WebLinkAbout20130223 Ver 3_Application_20150608 STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION PAT L. MCCRORY ANTHONY J. TATA GOVERNOR SECRETARY June 8, 2015 U. S. Army Corps of Engineers Regulatory Field Office 3331 Heritage Trade Drive, Suite 105 Wake Forest, NC 27587 ATTN: Mr. Dave Bailey NCDOT Coordinator SUBJECT: Request for Modification to the Section 404 Individual Permit and Section 401 Water Quality Certification for the proposed Greensboro Western Loop from north of SR 2176 (Bryan Boulevard) to SR 2303 (Lawndale Drive), Guilford County, Division 7. Federal Aid Project No. STP-NHF-124(1), WBS Element No. 34820.1.2, TIP No. U-2524C and D. REFERENCE: USACE Individual Permit Action ID SAW-2001-21125, dated August 1, 2013. USACE Individual Permit Modification Action ID SAW-2001-21125, dated March 25, 2014. NCDWR Project No. 20130223, Certification No. 3965, dated July 2, 2013. NCDWR Project No. 20130223_v2, Modification to Certification No. 3965, dated April 15, 2014. Dear Sir: The purpose of this letter is to request a modification to the United States Army Corps of Engineers (USACE) Section 404 Individual Permit and North Carolina Division of Water Resources Section 401 Certification for the above referenced project. The NCDOT is submitting for approval of mechanized clearing in a wetland for noise wall construction resulting in an additional 0.01 acres of permanent wetland impact (Permit Site 13). A 30-foot wide path has been proposed in the wetland located at Permit Site 13 to allow a 26-foot wide crane to place stone to ensure a solid foundation in the wetland for the noise wall construction. Once construction of the noise wall is complete, the stone will be removed. Please see Table 1 below and the attached revised Permit Drawing Sheets 25, 26, and 39 of 39. Table 2 on page 3 has been updated to show current required mitigation from the NC Division of Mitigation Services (DMS) for Section C. The DMS acceptance letter is forthcoming. MAILING ADDRESS: NC DEPARTMENT OF TRANSPORTATION PROJECT DEVELOPMENT & ENVIRONMENTAL ANALYSIS UNIT 1598 MAIL SERVICE CENTER RALEIGH NC 27699-1548 TELEPHONE: 919-707-6000 FAX: 919-212-5785 WEBSITE:NCDOT.GOV LOCATION: CENTURY CENTER, BUILDING B 1020 BIRCH RIDGE DRIVE RALEIGH NC 27610 Table 1. Revised U-2524C Wetland Impacts (Final) Permit Site No. Wetland ID in CP 4A Packet JD Package ID Impact Type Permanent Impacts (ac) Temporary Impacts (ac) 1 1W WA and WB Permanent Fill 0.10 Mechanized Clearing 0.02 7 Not Identified WC and WD Permanent Fill 0.01 9 11W and 12W WE, WF, WG, WH Mechanized Clearing 0.02 10A 13W WI Mechanized Clearing 0.01 10A 13W WJ Temporary Fill 0.01 11 13W WK Mechanized Clearing 0.19 12 13W WL Permanent Fill 1.93 (2:1 Ratio) 0.64 (1:1 Ratio) Mechanized Clearing 0.34 (2:1 Ratio) 0.02 (1:1 Ratio) 13 13W WM Permanent Fill 0.59 (2:1 Ratio) 0.65 (1:1 Ratio) Excavation 0.34 (2:1 Ratio) Mechanized Clearing 0.23 (2:1 Ratio)1 0.42 (1:1 Ratio) 13 Revised2 15W WP Permanent Fill 0.01 (2:1 Ratio) 14 15W WQ Permanent Fill 0.11 W1 13W WL Mechanized Clearing 0.20 W2 13W WM Temporary Excavation 0.79 W3 15W WN Mechanized Clearing 0.12 W4 15W WQ Mechanized Clearing 0.01 1* 15W WN Mechanized Clearing 0.14 2* 15W WO Mechanized Clearing 0.04 3* 15W WP Mechanized Clearing 0.01 Total Impacts 6.15 0.80 Notes: Permit Site Nos. W1 - W4 are from Colonial Pipe Line utilities and Permit Site Nos. 1* - 3* are from Plantation Pipe Line utilities. Most permanent impacts require 2:1 mitigation except for Permit Sites 12 and 13 within the utility easement which USACE determined as 1:1 mitigation. 1 Revised as of June 2, 2015 for noise wall construction. 2 Revised as of March 25, 2014 Permit Modification from USACE and April 15, 2014 Water Quality Certification from NCDWR. U-2524C & U-2524D Individual Permit Modification Application 2