HomeMy WebLinkAbout20130223 Ver 3_Application_20150608
STATE OF NORTH CAROLINA
DEPARTMENT OF TRANSPORTATION
PAT L. MCCRORY ANTHONY J. TATA
GOVERNOR SECRETARY
June 8, 2015
U. S. Army Corps of Engineers
Regulatory Field Office
3331 Heritage Trade Drive, Suite 105
Wake Forest, NC 27587
ATTN: Mr. Dave Bailey
NCDOT Coordinator
SUBJECT: Request for Modification to the Section 404 Individual Permit and Section 401
Water Quality Certification for the proposed Greensboro Western Loop from north of
SR 2176 (Bryan Boulevard) to SR 2303 (Lawndale Drive), Guilford County, Division 7.
Federal Aid Project No. STP-NHF-124(1), WBS Element No. 34820.1.2, TIP No.
U-2524C and D.
REFERENCE: USACE Individual Permit Action ID SAW-2001-21125, dated August 1, 2013.
USACE Individual Permit Modification Action ID SAW-2001-21125, dated March 25,
2014.
NCDWR Project No. 20130223, Certification No. 3965, dated July 2, 2013.
NCDWR Project No. 20130223_v2, Modification to Certification No. 3965, dated April
15, 2014.
Dear Sir:
The purpose of this letter is to request a modification to the United States Army Corps of Engineers
(USACE) Section 404 Individual Permit and North Carolina Division of Water Resources Section 401
Certification for the above referenced project. The NCDOT is submitting for approval of mechanized
clearing in a wetland for noise wall construction resulting in an additional 0.01 acres of permanent
wetland impact (Permit Site 13). A 30-foot wide path has been proposed in the wetland located at Permit
Site 13 to allow a 26-foot wide crane to place stone to ensure a solid foundation in the wetland for the
noise wall construction. Once construction of the noise wall is complete, the stone will be removed.
Please see Table 1 below and the attached revised Permit Drawing Sheets 25, 26, and 39 of 39. Table 2
on page 3 has been updated to show current required mitigation from the NC Division of Mitigation
Services (DMS) for Section C. The DMS acceptance letter is forthcoming.
MAILING ADDRESS:
NC DEPARTMENT OF TRANSPORTATION
PROJECT DEVELOPMENT & ENVIRONMENTAL ANALYSIS UNIT
1598 MAIL SERVICE CENTER
RALEIGH NC 27699-1548
TELEPHONE: 919-707-6000
FAX: 919-212-5785
WEBSITE:NCDOT.GOV
LOCATION:
CENTURY CENTER, BUILDING B
1020 BIRCH RIDGE DRIVE
RALEIGH NC 27610
Table 1. Revised U-2524C Wetland Impacts (Final)
Permit
Site No.
Wetland ID
in CP 4A
Packet
JD Package
ID Impact Type Permanent
Impacts (ac)
Temporary
Impacts (ac)
1 1W WA and WB
Permanent Fill 0.10
Mechanized
Clearing 0.02
7 Not Identified WC and WD Permanent Fill 0.01
9 11W and 12W WE, WF,
WG, WH
Mechanized
Clearing 0.02
10A 13W WI Mechanized
Clearing 0.01
10A 13W WJ Temporary Fill 0.01
11 13W WK Mechanized
Clearing 0.19
12 13W WL
Permanent Fill 1.93 (2:1 Ratio)
0.64 (1:1 Ratio)
Mechanized
Clearing
0.34 (2:1 Ratio)
0.02 (1:1 Ratio)
13 13W WM
Permanent Fill 0.59 (2:1 Ratio)
0.65 (1:1 Ratio)
Excavation 0.34 (2:1 Ratio)
Mechanized
Clearing
0.23 (2:1 Ratio)1
0.42 (1:1 Ratio)
13
Revised2 15W WP Permanent Fill 0.01 (2:1 Ratio)
14 15W WQ Permanent Fill 0.11
W1 13W WL Mechanized
Clearing 0.20
W2 13W WM Temporary
Excavation 0.79
W3 15W WN Mechanized
Clearing 0.12
W4 15W WQ Mechanized
Clearing 0.01
1* 15W WN Mechanized
Clearing 0.14
2* 15W WO Mechanized
Clearing 0.04
3* 15W WP Mechanized
Clearing 0.01
Total Impacts 6.15 0.80
Notes: Permit Site Nos. W1 - W4 are from Colonial Pipe Line utilities and Permit Site Nos. 1* - 3* are from Plantation Pipe Line
utilities. Most permanent impacts require 2:1 mitigation except for Permit Sites 12 and 13 within the utility easement which
USACE determined as 1:1 mitigation. 1 Revised as of June 2, 2015 for noise wall construction. 2 Revised as of March 25, 2014
Permit Modification from USACE and April 15, 2014 Water Quality Certification from NCDWR.