Loading...
HomeMy WebLinkAboutAttachment 1 - Lake_Lure_Dam_Reservoir_Drain_Drawings_For_Bid_February_2023 (2)18C21024.020 SHEET DE S I G N E D B Y : DR A W N B Y : CH E C K E D B Y : DA T E RE V . \\ G R E E - F S \ P R O J E C T S \ 2 0 1 8 \ G R E E N S B O R O \ 1 8 C 2 1 0 2 4 _ 0 0 _ L A K E _ L U R E _ D A M \ 0 3 - S E P R O D U C T S \ 0 8 - C A D \ D R A W I N G S \ 0 5 - F I N A L _ D E S I G N \ U N D E R D R A I N D E S I G N \ C O V E R _ L E G E N D . D W G © Schnabel Engineering 2023 All Rights Reserved LI C E N S E N U M B E R : C - 2 5 9 9 11 A O A K B R A N C H D R I V E / G R E E N S B O R O , N C / 2 7 4 0 7 Ph o n e : 3 3 6 - 2 7 4 - 9 4 5 6 sc h n a b e l - e n g . c o m LA K E L U R E D A M R E S E R V O I R D R A I N TO W N O F L A K E L U R E RU T H E R F O R D C O U N T Y , N C CH A R L E S M . J O H N S O N , P . E . NO R T H C A R O L I N A P R O F E S S I O N A L E N G I N E E R N O . 0 3 6 1 8 3 DA T E : PROJECT: DATE: FOR BID FEBRUARY 2023 NOT ISSUED FOR CONSTRUCTION DE S C R I P T I O N NLPN 036183 E N EGIN E R ASE L A R O HTOR L O C AR ISESFONA I C H A RLES M . J O H NSON 1 OF 16 CO V E R S H E E T LAKE LURE DAM RESERVOIR DRAIN NC DAM SAFETY ID RUTHE-003 PREPARED FOR TOWN OF LAKE LURE RUTHERFORD COUNTY, NORTH CAROLINA PREPARED BY SCHNABEL ENGINEERING SOUTH, PC PROJECT NO. 18C21024.020 RUTHERFORD COUNTY KEY MAPLOCATION MAPVICINITY MAP PROJECT SITE PROJECT SITE BUFFA L O S H O A L S R D N N ☆ SK NA M CM J 18C21024.020 SHEET DE S I G N E D B Y : DR A W N B Y : CH E C K E D B Y : DA T E RE V . \\ G R E E - F S \ P R O J E C T S \ 2 0 1 8 \ G R E E N S B O R O \ 1 8 C 2 1 0 2 4 _ 0 0 _ L A K E _ L U R E _ D A M \ 0 3 - S E P R O D U C T S \ 0 8 - C A D \ D R A W I N G S \ 0 5 - F I N A L _ D E S I G N \ U N D E R D R A I N D E S I G N \ C O V E R _ L E G E N D . D W G © Schnabel Engineering 2023 All Rights Reserved LI C E N S E N U M B E R : C - 2 5 9 9 11 A O A K B R A N C H D R I V E / G R E E N S B O R O , N C / 2 7 4 0 7 Ph o n e : 3 3 6 - 2 7 4 - 9 4 5 6 sc h n a b e l - e n g . c o m LA K E L U R E D A M R E S E R V O I R D R A I N TO W N O F L A K E L U R E RU T H E R F O R D C O U N T Y , N C CH A R L E S M . J O H N S O N , P . E . NO R T H C A R O L I N A P R O F E S S I O N A L E N G I N E E R N O . 0 3 6 1 8 3 DA T E : PROJECT: DATE: FOR BID FEBRUARY 2023 NOT ISSUED FOR CONSTRUCTION DE S C R I P T I O N NLPN 036183 E N EGIN E R ASE L A R O HTOR L O C AR ISESFONA I C H A RLES M . J O H NSON SK NA M CM J 2 OF 16 LE G E N D A N D S H E E T I N D E X EXISTING FEATURES LEGEND PROFILE INDICATOR DIRECTION WHICH PROFILE IS SHOWN 2 8 ADDITIONAL INFORMATION PLAN / SECTION / DETAIL1 2 A-115 DRAWING SYMBOLS LEGEND SECTION INDICATOR SECTION NUMBER* DRAWING NUMBER ON WHICH SECTION APPEARS PLAN, SECTION OR DETAIL LABEL DIRECTION WHICH SECTION IS SHOWN PLAN, SECTION OR DETAIL NUMBER SCALE INDICATOR VERBAL SCALE** * SECTION AND ELEVATION INDICATORS ARE SIMILAR. SECTION AND ELEVATION NUMBERS ARE COMBINED AND SEQUENTIAL ON EACH DRAWING. ** VERBAL SCALE IS SHOWN FOR CONVENIENCE. ALL DRAWINGS SHOULD BE CHECKED TO ENSURE THAT THE SCALE BAR ITSELF IS SHOWN AT ACTUAL SIZE. DRAWINGS NOT PLOTTED AT THEIR INTENDED SIZE (ANSI D 22" x 34") WILL NOT SCALE PROPERLY. 1.00"0.75"1.50" PLAN, SECTION OR DETAIL TITLE DETAIL INDICATOR 4 A-110 DETAIL NUMBER DRAWING NUMBER ON WHICH DETAIL APPEARS OPTIONAL ADDITIONAL INFORMATION 00 1'2' SCALE: 3/4"=1'0" 00 2'4' SCALE: 1/2"=1'0" 00 1' SCALE: 1-1/2"=1'0" 2' ABBREVIATIONS AB ANCHOR BOLTS ABC AGGREGATE BASE COURSE AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION ALT ALTERNATIVE, ALTERNATE ANC ANCHOR APPROX APPROXIMATE ARV AIR RELEASE VALVE ASSY ASSEMBLY AWS AMERICAN WELDING SOCIETY BM BENCH MARK BOT BOTTOM BF BOTTOM FACE C-C CENTER TO CENTER CHK CHECK CIP CAST IRON PIPE CG CENTER OF GRAVITY CJ CONSTRUCTION JOINT CJP COMPLETE JOINT PENETRATION WELD CL CENTERLINE CLR CLEAR CRJ CONTRACTION JOINT CTJ CONTROL JOINT CTR CENTER, CENTERS CNTR CENTER CONC CONCRETE CONN CONNECTION CONT CONTINUOUS CSP CONCRETE SURFACE PROFILE DBA DEFORMED BAR ANCHOR DEG DEGREES DET DETAIL DI DUCTILE IRON DIA DIAMETER DIP DUCTILE IRON PIPE D/S DOWNSTREAM DWG DRAWING DWL DOWEL EA EACH EF EACH FACE EJ EXPANSION JOINT EL ELEVATION EMB EMBEDMENT EQ EQUAL ES EQUAL SPACES, EQUALLY SPACED EW EACH WAY EXP ANC EXPANSION ANCHOR FF FAR FACE FS FAR SIDE GALV GALVANIZED GV GATE VALVE GPM GALLONS PER MINUTE HEX HEXAGONAL HD HEAD HDPE HIGH DENSITY POLYETHYLENE HK HOOK HLS HOLES HORIZ HORIZONTAL HS HIGH STRENGTH HW HEADWATER ID INSIDE DIAMETER IN INCHES INJ INJECTION KIP KILOPOUND KSI KIPS PER SQUARE INCH LB POUND LF LENGTH FOOT LFT LEFT Lg LARGE LG LONG, LENGTH MAX MAXIMUM MIN MINIMUM MJ MECHANICAL JOINT NAVD 88 NORTH AMERICAN VERTICAL DATUM OF 1988 NCDOT NORTH CAROLINA DEPARTMENT OF TRANSPORTATION NF NEAR FACE NOM NOMINAL NPT NATIONAL PIPE TAPERED NS NEAR SIDE NTS NOT TO SCALE OC ON CENTER OCJ OPTIONAL CONSTRUCTION JOINT OD OUTSIDE DIAMETER PCF POUNDS PER CUBIC FOOT PERP PERPENDICULAR PL PLATE PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT ANC POST-TENSIONED ANCHOR PROJ PROJECT PVC POLYVINYL CHLORIDE PIPE R RADIUS RCP REINFORCED CONCRETE PIPE REINF REINFORCING, REINFORCED REF REFERENCE REQD REQUIRED RJ RESTRAINED JOINT RT RIGHT RHT RIGHT HAND THREAD SHT SHEET SIM SIMILAR SL STOP LOG SP SPACE SPEC SPECIFICATION SS STAINLESS STEEL STA STATION STD STANDARD STL STEEL SQ SQUARE SYM SYMMETRICAL T/TOP OF TBD TO BE DETERMINED TEMP TEMPORARY TF TOP FACE TH TEST HOLE THK THICK TR TRASH RACK TYP TYPICAL TW TAILWATER UNO UNLESS NOTED OTHERWISE U/S UPSTREAM UV UNIFORMLY VARYING VERT VERTICAL W/WITH WL WATERLINE WTP WATER TREATMENT PLANT W/O WITHOUT WP WORKING POINT WS WATER STOP Ø DIAMETER LIGHT POLE SEWER MANHOLE TREE LIMITS OF DISTURBANCE SANITARY SEWER LINE EXISTING TREELINE CONCRETE ASPHALT FILTER SAND GRAVEL DRAINFILL S LOD LOD SS SS ELECTRICAL POLE LAKE LURE WATER SURFACE 2 8 DRAWING NUMBER ON WHICH PROFILE APPEARS PROFILE NUMBER* CONSTRUCTION ENTRANCE Sheet List Table Sheet Number Sheet Title 1 COVER SHEET 2 LEGEND AND SHEET INDEX 3 STRUCTURAL GENERAL NOTES 4 EXISTING SITE PLAN 5 SITE AND ACCESS PLAN 6 ACCESS ROAD PLAN & PROFILE 7 EROSION & SEDIMENT CONTROL DETAILS 8 SEWER LINE REPLACEMENT PLAN 9 BAY 5 ENCASEMENT PLAN 10 STRUCTURAL PHASE 1 - SECTION 11 STRUCTURAL PHASE 2 - SECTION 12 CONCRETE ENCASEMENT DETAILS 13 PRECAST CONCRETE PORTAL AND CONCRETE CRADLE DETAILS 14 RESERVOIR DRAIN DETAILS 15 BULKHEAD DETAILS 1 16 BULKHEAD DETAILS 2 SS SS SS SS SS SS SS SS SSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS V o o o o o o o o o o o ooooooo o o o o o o o o o o o o o o o ooo o o o o oooooo o o o o o o o o o o o o o o o o o o o ooooo o o SS SS S S S S 7+000+00 1+00 2+00 3+00 4+00 5+00 6+00 89 0 90 0 90 0 91 0 9 1 0 92 0 9 2 0 93 0 93 0 9 4 0 94 0 95 0 9 5 0 96 0 96 0 97 0 970 980 98 0 990 9 9 0 99 0 100 0 1 0 0 0 1000 1 0 1 0 1 0 1 0 10 2 0 1 0 2 0 10 3 0 1 0 3 0 1 0 4 0 1 0 4 0 10 5 0 1 0 5 0 950 960 960 970 970 980 980 990 990 1000 10 0 0 101 0 10 2 0 1 0 0 0 NAIL 1000.14 NAIL 928.90 DISC 932.83 NAIL 933.99 NAIL 936.39 NAIL 1003.53 NAIL 1003.56 NAIL 922.66 DISC 1004.40 DCG 1002.91 RR SPIKE 1005.80 RR SPIKE 1006.57 DISC 1003.35 BR O A D R I V E R BAY #1 BAY #2 BAY #3 BAY #4 BAY #5 BAY #6 BAY #7 BAY #8 BAY #9 BAY #10 BAY #11 BAY #12 BAY #13 LAKE LURE BU F F A L O S H O A L S R O A D STARTER BLOCK THRUST BLOCK LIFT STATION RECEIVING WELL CONCRETE SLAB EDGE OF SHALLOW POOLING 6-IN DIA PVC SANITARY SEWER BLOW-OFF LINE 18-IN DIA DIP SANITARY SEWER LINE SEE NOTE 3 SURFACE BOULDERS WITHIN HATCH AREA PUMP STATION JUNCTION BOX 18C21024.020 SHEET DE S I G N E D B Y : DR A W N B Y : CH E C K E D B Y : DA T E RE V . \\ G R E E - F S \ P R O J E C T S \ 2 0 1 8 \ G R E E N S B O R O \ 1 8 C 2 1 0 2 4 _ 0 0 _ L A K E _ L U R E _ D A M \ 0 3 - S E P R O D U C T S \ 0 8 - C A D \ D R A W I N G S \ 0 5 - F I N A L _ D E S I G N \ U N D E R D R A I N D E S I G N \ E X I S T I N G _ P L A N . D W G © Schnabel Engineering 2023 All Rights Reserved LI C E N S E N U M B E R : C - 2 5 9 9 11 A O A K B R A N C H D R I V E / G R E E N S B O R O , N C / 2 7 4 0 7 Ph o n e : 3 3 6 - 2 7 4 - 9 4 5 6 sc h n a b e l - e n g . c o m LA K E L U R E D A M R E S E R V O I R D R A I N TO W N O F L A K E L U R E RU T H E R F O R D C O U N T Y , N C CH A R L E S M . J O H N S O N , P . E . NO R T H C A R O L I N A P R O F E S S I O N A L E N G I N E E R N O . 0 3 6 1 8 3 DA T E : PROJECT: DATE: FOR BID FEBRUARY 2023 NOT ISSUED FOR CONSTRUCTION DE S C R I P T I O N NLPN 036183 E N EGIN E R ASE L A R O HTOR L O C AR ISESFONA I C H A RLES M . J O H NSON EX I S T I N G S I T E P L A N 00 30'60' SCALE: 1"=30' JM P NA M CM J 3 OF 16 EXISTING SITE PLAN1 FLOW NOTES 1. EXISTING STRUCTURE IS BASED ON SURVEY PERFORMED BY ED HOLMES AND ASSOCIATES LAND SURVEYORS, PA DATED JANUARY 9TH, 2019. 2. THE SURVEY VERTICAL DATUM IS NAVD 88. 3. THE PORTION OF SANITARY SEWER LINE BETWEEN THE UPSTREAM FACE OF BAY 5 AND THE LIFT STATION STRUCTURE IS GENERALLY EXPOSED ABOVE GRADE. THE PORTION OF THE SANITARY SEWER LINE DOWNSTREAM OF THE LIFT STATION IS BELOW GRADE. THE PORTION OF THE SANITARY SEWER LINE UPSTREAM OF THE DAM IS AT OR NEAR THE BOTTOM OF THE RESERVOIR. 4. LOCATIONS OF UTILITIES SHOWN ON THIS SURVEY WERE DETERMINED BY OBSERVED EVIDENCE, LOCATION OF ABOVE GROUND UTILITY APPURTENANCES, GIS INFORMATION AND UTILITY MARKINGS (PAINT, ETC.) PROVIDED BY ED HOLMES & ASSOCIATES. THESE MARKINGS WERE OBSERVED DURING THE COURSE OF THIS SURVEY, WERE FIELD LOCATED, ARE SHOWN FOR INFORMATIONAL PURPOSES, AND SHOULD BE FIELD VERIFIED IF CRITICAL. UNDERGROUND UTILITIES NOT SHOWN, MAY EXIST. STORM SEWER AND SANITARY SEWER DATA HAS BEEN COLLECTED FROM THE RIM OF THE MANHOLE WITHOUT ENTERING THE STRUCTURE. PIPE SIZES AND TYPES SHOULD BE CONSIDERED APPROXIMATE AND BE FIELD VERIFIED IF CRITICAL. PAVED ACCESS ROAD N B U F F A L O S H O A L S R O A D ELECTRICAL SUBSTATION LARGE BOULDERS MEDIUM BOULDERS INTAKE TOWER POWERHOUSE CONCRETE ACCESS RAMP TOWN LAKE OPERATIONS BUILDING PEDESTRIAN RIVER CROSSING OVER SANITARY SEWER LINE WOODEN STAIRS NORMAL POOL EL 990.5 SPILLWAY RADIAL GATES IN BAYS 1-3 MANHOLE BRIDGE/DAM CENTER LINE ACCESS DURING PRE-BID 960 970 980 990 1000 1010 890 890 LOD LO D LO D LO D LOD LOD LO D LOD LOD LOD LOD LOD LO D LO D LO D LOD LOD LOD LOD LOD LOD LOD LOD LO D LOD LOD LOD LO D LO D LO D LO D LOD LOD LOD LOD LOD L O D LOD LOD LOD LOD LOD LOD LO D LOD LOD LOD LO D LOD LO D LO DLOD LOD LO D LO D L O D L O D L O D L O D LO D LO D LO D L O D LOD L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D 7+000+00 1+00 2+00 3+00 4+00 5+00 6+00 LO D LO D LO D LO D LO D LO D LO D LO D LO D L O D LOD LO D LO D LO D LO D LO D LO D LO D LO D LOD L O D L O D L O D LOD L O D L O D LOD L O D L O D L O D L O D L O D LOD LOD LOD L O D L O D 45' 50' SS SS SS SS SS SS SS SS SSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS V o o o o o o o o o o o oooooooo o o o o o o o o o o o o S o o ooo o o o o ooooo o o o o o o o o o o o o o o S o o o o o o ooooo o S S SS SS S S S S 0+0 0 1+0 0 2+0 0 3+ 0 0 3+ 7 0 0+5 0 1+5 0 2+50 3+ 5 0 18C21024.020 SHEET DE S I G N E D B Y : DR A W N B Y : CH E C K E D B Y : DA T E RE V . \\ G R E E - F S \ P R O J E C T S \ 2 0 1 8 \ G R E E N S B O R O \ 1 8 C 2 1 0 2 4 _ 0 0 _ L A K E _ L U R E _ D A M \ 0 3 - S E P R O D U C T S \ 0 8 - C A D \ D R A W I N G S \ 0 5 - F I N A L _ D E S I G N \ U N D E R D R A I N D E S I G N \ E X I S T I N G _ A C C E S S _ P L A N . D W G © Schnabel Engineering 2023 All Rights Reserved LI C E N S E N U M B E R : C - 2 5 9 9 11 A O A K B R A N C H D R I V E / G R E E N S B O R O , N C / 2 7 4 0 7 Ph o n e : 3 3 6 - 2 7 4 - 9 4 5 6 sc h n a b e l - e n g . c o m LA K E L U R E D A M R E S E R V O I R D R A I N TO W N O F L A K E L U R E RU T H E R F O R D C O U N T Y , N C CH A R L E S M . J O H N S O N , P . E . NO R T H C A R O L I N A P R O F E S S I O N A L E N G I N E E R N O . 0 3 6 1 8 3 DA T E : PROJECT: DATE: FOR BID FEBRUARY 2023 NOT ISSUED FOR CONSTRUCTION DE S C R I P T I O N NLPN 036183 E N EGIN E R ASE L A R O HTOR L O C AR ISESFONA I C H A RLES M . J O H NSON SI T E A N D A C C E S S P L A N SK NA M CM J 4 OF 16 NOTES 1. THE TEMPORARY ACCESS ROADS AND RIVER CROSSING SHALL BE CONSTRUCTED IN GENERAL ACCORDANCE WITH NCDOT REQUIREMENTS FOR TEMPORARY STREAM CROSSINGS. THE CONTRACTOR IS RESPONSIBLE FOR SUBMITTING AN ACCESS ROAD AND RIVER CROSSING PLAN TO THE ENGINEER FOR APPROVAL AS DEFINED IN SECTION 01 50 00 OF THE TECHNICAL SPECIFICATIONS. UPON COMPLETION OF CONSTRUCTION, THE CONTRACTOR SHALL LEAVE THE ACCESS ROADS AND RIVER CROSSING IN PLACE FOR FUTURE USE BY THE OWNER. 2. CONTRACTOR SHALL FOLLOW ALL RECOMMENDATIONS IN NORTH CAROLINA DEQ EROSION & SEDIMENT CONTROL HANDBOOK. IF DISTURBANCE IS MINIMIZED TO LESS THAN 1 ACRE, NO EROSION & SEDIMENT CONTROL PERMITTING IS REQUIRED. STANDARD EROSION & SEDIMENT CONTROL DETAILS ARE SHOWN ON SHEET 6. 3. THE PRIMARY OFF-SITE LAYDOWN AND STAGING AREA (1 TO 2 ACRES) IS LOCATED ADJACENT TO THE LAKE LURE GOLF CLUB AT 658 MEMORIAL HIGHWAY, LAKE LURE, NC. CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ACCESS TO THIS AREA. THE CONTRACTOR SHALL SECURE ADDITIONAL OFF-SITE LAYDOWN AND STAGING AREA PROVIDED THIS AREA AND THE ON-SITE AREAS SHOWN ARE NOT ADEQUATE FOR EQUIPMENT AND MATERIAL STORAGE AND CONTRACTOR PARKING. ACCESS ROAD ALIGNMENT SEE NOTE 1 AND DETAIL 3 ON SHEET 5 MINIMUM 12-FT WIDE GRAVEL ACCESS ROAD SEE NOTE 1 LOOSE BOULDERS REMOVED FROM THE BAY 5 CONSTRUCTION ACCESS AREA SHALL BE RELOCATED TO THIS AREA. BOULDERS SHALL BE PLACED FLAT AND UNIFORMLY TO THE BEST EXTENT POSSIBLE. CONTRACTOR TO GRADE AREA, INCLUDING REMOVAL OF LOOSE BOULDERS, AS NEEDED TO FACILITATE TEMPORARY CONSTRUCTION ACCESS TO BAY 5. DO NOT EXCAVATE ROCK IN THIS AREA. BAY #1 BAY #2 BAY #3 BAY #4 BAY #5 BAY #6 BAY #7 BAY #8 BAY #9 BAY #10 BAY #11 BAY #12 BAY #13 LAKE LURE BU F F A L O S H O A L S R O A D 00 30'60' SCALE: 1"=30' SITE AND ACCESS PLAN1 FLOW N B U F F A L O S H O A L S R O A D ELECTRICAL SUBSTATION TEMPORARY LAYDOWN AND STAGING AREAS. CONTRACTOR TO MAINTAIN A LANE FOR POWERHOUSE ACCESS ADDITIONAL TEMPORARY STAGING AND LAYDOWN AREAS RIVER CROSSING SEE NOTE 1 PROPOSED LIMITS OF DISTURBANCE PROPOSED LIMITS OF DISTURBANCE PROPOSED RESERVOIR DRAIN SEE DETAILS SHEETS 9 TO 16 1,000 SQFT 440 SQFT 3,620 SQFT 1,650 SQFT BRIDGE/DAM CENTER LINE SEE SHEET 5 FOR REMAINDER OF SITE ACCESS ROAD. SEE NOTE 3 THIS SHEET AND SHEET 5 FOR OFF-SITE LAYDOWN AND STAGING AREA. EX I S T I N G A C C E S S R O A D EXISTING SEWER PIPE (4) 65 FT, 48" DIA CULVERTS 95 0 97 5 1000 102 5 1050 1075 1100 1125 V EL E V A T I O N 870 880 890 900 910 920 930 940 950 960 970 980 870 880 890 900 910 920 930 940 950 960 970 980 0+00 1+00 2+00 3+00 3+70 0+15 0+30 0+45 0+60 0+75 0+90 1+05 1+20 1+35 1+50 1+65 1+80 1+95 2+10 2+25 2+40 2+55 2+70 2+85 3+00 3+15 3+30 3+45 3+60 3+70 EXISTING GRADE (4) 48" DIA CULVERTS GRAVEL ACCESS ROAD EMBANKMENT WITH 12-FT WIDE CREST GRAVEL ROAD AND CONSTRUCTION LAYDOWN AREA 0.0%-6.25% -20% -10.8% -18% 1% 10-YEAR STORM EL 894.5 NCDOT CLASS B RIPRAP OR EQUIVALENT WITH NCDOT CLASS 2 RIPRAP OR EQUIVALENT ON THE OUTER SHELLS OF THE EMBANKMENT PROJECT SITE OVERALL SITE ACCESS ROAD - PLAN1 18C21024.020 SHEET DE S I G N E D B Y : DR A W N B Y : CH E C K E D B Y : DA T E RE V . \\ G R E E - F S \ P R O J E C T S \ 2 0 1 8 \ G R E E N S B O R O \ 1 8 C 2 1 0 2 4 _ 0 0 _ L A K E _ L U R E _ D A M \ 0 3 - S E P R O D U C T S \ 0 8 - C A D \ D R A W I N G S \ 0 5 - F I N A L _ D E S I G N \ U N D E R D R A I N D E S I G N \ E X I S T I N G _ A C C E S S _ P L A N . D W G © Schnabel Engineering 2023 All Rights Reserved LI C E N S E N U M B E R : C - 2 5 9 9 11 A O A K B R A N C H D R I V E / G R E E N S B O R O , N C / 2 7 4 0 7 Ph o n e : 3 3 6 - 2 7 4 - 9 4 5 6 sc h n a b e l - e n g . c o m LA K E L U R E D A M R E S E R V O I R D R A I N TO W N O F L A K E L U R E RU T H E R F O R D C O U N T Y , N C CH A R L E S M . J O H N S O N , P . E . NO R T H C A R O L I N A P R O F E S S I O N A L E N G I N E E R N O . 0 3 6 1 8 3 DA T E : PROJECT: DATE: FOR BID FEBRUARY 2023 NOT ISSUED FOR CONSTRUCTION DE S C R I P T I O N NLPN 036183 E N EGIN E R ASE L A R O HTOR L O C AR ISESFONA I C H A RLES M . J O H NSON AC C E S S R O A D PL A N & P R O F I L E SK NA M CM J 5 OF 16 PAVED ACCESS ROAD PRIMARY ACCESS TO CONSTRUCTION AREA AND TOE OF DAM US HI G H W A Y 6 4 ALT HW Y 7 4 MEM O R I A L H I G H W A Y BUF F A L O S H O A L S R O A D N LAKE LURE TOWN WTP B R O A D R I V E R BROA D R I V E R PRIM A R Y A C C E S S T O T O P OF D A M A N D A L T E R N A T E STA G I N G A R E A S ENTRANCE COORDINATES LAT: 35.423711 LONG: -82.177409 NAD 1983 NC (US SURVEY FEET) N: 624,257.83 E: 1,053,582.70 RIVER CROSSING - PROFILE3 00 20'40' SCALE: 1"=20' 00 200'400' SCALE: 1"=200' ACCESS ROAD RIVER CROSSING NOTES: 1. CONTRACTOR SHALL PROVIDE AN INSTALLATION AND LAYOUT PLAN FOR THE RIVER CROSSING AS DEFINED IN SECTION 01 50 00 OF THE TECHNICAL SPECIFICATIONS. N OFF-SITE LAYDOWN AREA - PLAN2 00 100'200' SCALE: 1"=100' APPROXIMATE AREA FOR OFF-SITE LAYDOWN AREA OLD GOLF COURSE CLUBHOUSE 658 MEMORIAL HIGHWAY HW Y 6 4 M E M O R I A L H W Y PRIMARY OFF-SITE STAGING AREA LOCATED 0.4 MILES TO THE WEST AT THE LAKE LURE GOLF CLUB - SEE DETAIL 2 THIS SHEET 2-3" WASHED STONE EXI S T I N G P A V E M E N T 50' MIN. AS REQ U I R E D 12' M I N . 6" MIN. THICKNESS STEEL POST WIRE MESH FENCE FABRIC FASTENED TO UPSLOPE SIDE OF POSTS COMPACTED SOIL BACKFILL IN TRENCH 12" OF FABRIC INSTALLED BURIED 8" MIN. 24" MIN. 24" MAX. FABRIC HEIGHT 4" MIN. PLAN VIEW DISCHARGE HOSE PUMP ELEVATION VIEW WELL VEGETATED, GRASSY AREA FILTER BAG WELL VEGETATED AREA INTAKE HOSE CLAMPS DISCHARGE HOSE CLAMPS WELL VEGETATED, GRASSY AREA FILTER BAG INTAKE HOSE PUMP SEEDING DETAIL2 TEMPORARY SILT FENCE MATERIAL PROPERTY REQUIREMENTS TEST MATERIAL UNITS SUPPORTED1 SILT FENCE UNSUPPORTED1 SILT FENCE TYPE OF VALUE GRAB STRENGTH ASTM D 4632 N (LBS) MACHINE DIRECTION 400 550 MARV (90)(90) X-MACHINE DIRECTION 400 450 MARV (90)(90) PERMITTIVITY2 ASTM D 4491 SEC-1 0.05 0.05 MARV APPARENT OPENING SIZE2 ASTM D 4751 MM 0.60 0.60 MAX. ARV3 (US SIEVE #)(30)(30) ULTRAVIOLET STABILITY ASTM D 4355 % RETAINED STRENGTH 70% AFTER 500 HOURS OF EXPOSURE 70% AFTER 500 HOURS OF EXPOSURE TYPICAL 1 SILT FENCE SUPPORT SHALL CONSIST OF 14 GAUGE STEEL WIRE WITH A MESH SPACING OF 150 MM (6 INCHES), OR PREFABRICATED POLYMER MESH OF EQUIVALENT STRENGTH. 2 THESE DEFAULT VALUES ARE BASED ON EMPIRICAL EVIDENCE WITH A VARIETY OF SEDIMENT. FOR ENVIRONMENTALLY SENSITIVE AREAS, A REVIEW OF PREVIOUS EXPERIENCE AND/OR SITE OR REGIONALLY SPECIFIC GEOTEXTILE TESTS IN ACCORDANCE WITH ASTM D 5141 SHOULD BE PERFORMED TO CONFIRM SUITABILITY OF THESE REQUIREMENTS. 3 AS MEASURED IN ACCORDANCE WITH ASTM D 4632. 18C21024.020 SHEET DE S I G N E D B Y : DR A W N B Y : CH E C K E D B Y : DA T E RE V . \\ G R E E - F S \ P R O J E C T S \ 2 0 1 8 \ G R E E N S B O R O \ 1 8 C 2 1 0 2 4 _ 0 0 _ L A K E _ L U R E _ D A M \ 0 3 - S E P R O D U C T S \ 0 8 - C A D \ D R A W I N G S \ 0 5 - F I N A L _ D E S I G N \ U N D E R D R A I N D E S I G N \ E X I S T I N G _ A C C E S S _ P L A N . D W G © Schnabel Engineering 2023 All Rights Reserved LI C E N S E N U M B E R : C - 2 5 9 9 11 A O A K B R A N C H D R I V E / G R E E N S B O R O , N C / 2 7 4 0 7 Ph o n e : 3 3 6 - 2 7 4 - 9 4 5 6 sc h n a b e l - e n g . c o m LA K E L U R E D A M R E S E R V O I R D R A I N TO W N O F L A K E L U R E RU T H E R F O R D C O U N T Y , N C CH A R L E S M . J O H N S O N , P . E . NO R T H C A R O L I N A P R O F E S S I O N A L E N G I N E E R N O . 0 3 6 1 8 3 DA T E : PROJECT: DATE: FOR BID FEBRUARY 2023 NOT ISSUED FOR CONSTRUCTION DE S C R I P T I O N NLPN 036183 E N EGIN E R ASE L A R O HTOR L O C AR ISESFONA I C H A RLES M . J O H NSON ER O S I O N & S E D I M E N T CO N T R O L D E T A I L S SK NA M CM J 6 OF 16 N.T.S. SILT FENCE DETAIL1 N.T.S. CONSTRUCTION ENTRANCE DETAIL3 MATERIALS: 1. USE A SYNTHETIC FILTER FABRIC OF AT LEAST 95% BY WEIGHT OF POLYOLEFINS OR POLYESTER, WHICH IS CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS CONFORMING TO THE REQUIREMENTS IN ASTM D 6461, WHICH IS SHOWN IN PART BELOW. SYNTHETIC FILTER FABRIC SHOULD CONTAIN ULTRAVIOLET RAY INHIBITORS AND STABILIZERS TO PROVIDE A MINIMUM OF 6 MONTHS OF EXPECTED USABLE CONSTRUCTION LIFE AT A TEMPERATURE RANGE OF 0 TO 120°F. 2. POSTS FOR SEDIMENT FENCES SHALL BE 1.33 LB/LINEAR FT STEEL WITH A MINIMUM LENGTH OF 5 FT. POSTS SHALL HAVE PROJECTIONS TO FACILITATE FASTENING THE FABRIC. 3. FOR REINFORCEMENT OF STANDARD STRENGTH FILTER FABRIC, USE WIRE FENCE WITH A MINIMUM 14 GAUGE AND A MAXIMUM MESH SPACING OF 6 INCHES. CONSTRUCTION NOTES: 1. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED 24 INCHES ABOVE THE GROUND SURFACE. 2. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID JOINTS. WHEN JOINTS ARE NECESSARY, SECURELY FASTEN THE FILTER FABRIC ONLY AT A SUPPORT POST WITH 4 FEET MINIMUM OVERLAP TO THE NEXT POST. 3. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS USING TIE WIRES. EXTEND THE WIRE MESH SUPPORT TO THE BOTTOM OF THE TRENCH. FASTEN THE WIRE REINFORCEMENT, THEN FABRIC ON THE UPSLOPE SIDE OF THE FENCE POST. WIRE OR PLASTIC ZIP TIES SHALL HAVE A MINIMUM 50-POUND TENSILE STRENGTH. 4. SPACE POSTS A MAXIMUM OF 6 FT FOR UNSUPPORTED SEDIMENT FENCE AND 8 FT FOR SUPPORTED SEDIMENT FENCE. SUPPORT POSTS SHOULD BE DRIVEN SECURELY INTO THE GROUND TO A MINIMUM OF 24 INCHES. 5. EXCAVATE A TRENCH APPROXIMATELY 4 INCHES WIDE AND 8 INCHES DEEP ALONG THE PROPOSED LINE OF POSTS AND UPSLOPE FROM THE BARRIER. 6. PLACE 12 INCHES OF THE FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH. 7. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND COMPACT. 8. DO NOT ATTACH FILTER FABRIC TO EXISTING TREES. MAINTENANCE NOTES: 1. INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH SIGNIFICANT RAINFALL EVENT (1/2 INCH OR GREATER). MAKE ANY REQUIRED REPAIRS IMMEDIATELY. 2. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. 3. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. 4. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED WITH SEED AND MULCH. CONSTRUCTION NOTES: 1. CLEAR THE ENTRANCE AND EXIT AREA OF ALL VEGETATION, ROOTS, AND OTHER OBJECTIONABLE MATERIAL AND GRADE PROPERLY. 2. PLACE FILTER FABRIC OVER CLEARED AREA. 3. PLACE WASH STONE TO THE SPECIFIC GRADE AND DIMENSIONS SHOWN ON THE PLANS AND SMOOTH IT. 4. PROVIDE DRAINAGE TO CARRY WATER TO A SUITABLE OUTLET. MAINTENANCE NOTES: 1. MAINTAIN THE STONE PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOPDRESSING WITH 2-INCH STONE. 2. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. 3. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS. NOTES 1. COARSE AGGREGATE: 2-3 INCH WASHED STONE 2. MINIMUM THICKNESS: 6 INCHES 3. MINIMUM LENGTH: 50 FEET 4. MINIMUM WIDTH: 25 FEET 5. GEOTEXTILE: REQUIRED TO SEPARATE COARSE AGGREGATE FROM SUBGRADE 6. MAINTAIN TO PREVENT TRANSPORT OF SEDIMENT ONTO PUBLIC ROADS. PLACE ADDITIONAL COARSE AGGREGATE AS CONDITIONS DEMAND. PERMANENT SEEDING: LIME: BASED ON SOIL TEST OR 2 TONS/ACRE FERTILIZER: BASED ON SOIL TEST OR 1000 LBS/ACRE OF 5-10-10 FERTILIZER SEEDING MIXTURE: SEED TYPES: SEEDING RATES: (POUNDS/ACRE): TALL FESCUE 100 RYE GRAIN 40 KOREAN LESPEDEZA 20 TEMPORARY SEEDING: LIME: 1 TON/ACRE FERTILIZER: 1000 LBS/ACRE OF 10-10-10 FERTILIZER (RYE ONLY) 750 LBS/ACRE OF 10-10-10 FERTILIZER SEED TYPES:SEEDING DATES: SEEDING RATES: (POUNDS/ACRE): RYE GRAIN AUG 16 TO APRIL 30 120 KOREAN LESPEDEZA AUG 16 TO APRIL 30 40 RYE GRAIN MAY 1 TO AUG 15 120 GERMAN MILLET MAY 1 TO AUG 15 40 MULCH AND MATTING: TYPE AND RATE OF MULCH: CLEAN STRAW AT 2 TONS/ACRE METHOD OF ANCHORING: ANCHORED WITH TACKING AGENT APPROVED BY CONTRACTOR. TYPE OF MATTING: MATTING SHALL BE HEAVY TWISTED JUTE MESH. OPENING BETWEEN STRANDS SHALL BE APPROXIMATELY 1" SQUARE. GENERAL SEEDING NOTES: 1. IF WORK IN DISTURBED AREAS STOPS FOR MORE THAN 21 WORKING DAYS, TEMPORARY SEEDING SHALL BE APPLIED TO STABILIZE THE AREA. 2. TILL OR DISC THE PREPARED AREAS TO BE SEEDED TO A MINIMUM DEPTH OF FOUR (4) INCHES. REMOVE ALL STONES LARGER THAN THREE (3) INCHES ON ANY SIDE, STICKS, ROOTS, AND OTHER EXTRANEOUS MATERIALS AT THE SURFACE DURING THE BED PREPARATION. 3. RECOMPACT THE AREA USING A CULTIPACKER ROLLER. THE FINISHED GRADE SHALL BE A SMOOTH, EVEN SOIL SURFACE WITH A LOOSE, UNIFORMLY FINE TEXTURE. ALL RIDGES AND DEPRESSIONS SHALL BE REMOVED AND FILLED TO PROVIDE THE APPROVED SURFACE DRAINAGE. SEEDING OF GRADED AREAS IS TO BE DONE IMMEDIATELY AFTER FINISHED GRADES ARE OBTAINED AND SEEDBED PREPARATION IS COMPLETED. NOTIFICATION OF LAND RESOURCES SEDIMENT AND EROSION CONTROL SELF-INSPECTION PROGRAM: THE SEDIMENTATION POLLUTION CONTROL ACT WAS AMENDED IN 2006 TO REQUIRE THAT PERSONS RESPONSIBLE FOR LAND-DISTURBING ACTIVITIES INSPECT A PROJECT AFTER EACH PHASE OF THE PROJECT TO MAKE SURE THAT THE APPROVED EROSION AND SEDIMENTATION CONTROL PLAN IS BEING FOLLOWED. RULES DETAILING THE DOCUMENTATION OF THESE INSPECTIONS TOOK EFFECT OCTOBER 1, 2010. THE SELF-INSPECTION PROGRAM IS SEPARATE FROM THE WEEKLY SELF-MONITORING PROGRAM OF THE NPDES STORMWATER PERMIT FOR CONSTRUCTION ACTIVITIES. THE FOCUS OF THE SELF-INSPECTION REPORT IS THE INSTALLATION AND MAINTENANCE OF EROSION AND SEDIMENTATION CONTROL MEASURES ACCORDING TO THE APPROVED PLAN. THE CONTRACTOR SHALL CONDUCT THE INSPECTIONS AFTER EACH PHASE OF THE PROJECT, AND THE CONTRACTOR SHALL CONTINUE TO CONDUCT THE INSPECTIONS UNTIL PERMANENT GROUND COVER IS ESTABLISHED IN ACCORDANCE WITH NCGS 113A-54.1 AND 15A NCAC 4B.0131. THE SELF-INSPECTION REPORT FORM IS AVAILABLE FROM HTTPS://DEQ.NC.GOV/ABOUT/DIVISIONS/ENERGY-MINERAL-LAND-RESOURCES/EROSION-SEDIMENT-CONTROL/FORMS IF YOU HAVE QUESTIONS OR CANNOT ACCESS THE FORM, PLEASE CONTACT THIS OFFICE AT (910) 433-3300. N.T.S. SEDIMENT FILTER BAG3 FILTER BAG NOTES: 1. USE FILTER BAGS AS NECESSARY TO TREAT WATER PUMPED FROM EXCAVATION. 2. PLACE FILTER BAGS IN WELL VEGETATED AREAS UPSTREAM OF ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES. MAINTENANCE NOTES: 1. SEDIMENT FILTER BAG SHALL BE DISPOSED OF AND REPLACED WHEN IT IS 3/4 FULL OF SEDIMENT OR WHEN IT IS IMPRACTICAL FOR THE BAG TO FILTER THE SEDIMENT OUT AT A REASONABLE FLOW RATE. 2. INSPECT THE BAG INLET PERIODICALLY FOR DAMAGE AND/OR COME BLOCKAGE. N.T.S. COCONUT FIBER ROLL DETAIL4 GENERAL NOTES: 1. MATERIALS USED IN COCONUT FIBER ROLL TO BE 100% WOVEN COCONUT FIBER TWINE. 2. COCONUT FIBER ROLLS TO BE LOCATED AS SHOWN ON THE PLAN. 3. PRIOR TO INSTALLATION, CLEAR ALL OBSTRUCTIONS, INCLUDING ROCKS, CLODS, AND OTHER DEBRIS GREATER THAN ONE INCH THAT MAY INTERFERE WITH PROPER FUNCTION OF THE ROLL. 4. COCONUT FIBER ROLL SHALL BE INSTALLED ALONG THE GRADED SLOPE PARALLEL TO THE TOE OF THE SLOPE. 5. OAK OR OTHER DURABLE HARDWOOD STAKES 2 INCHES X 2 INCHES IN CROSS-SECTION SHALL BE DRIVEN VERTICALLY PLUMB, THROUGH THE CENTER OF THE ROLL. STAKES SHALL BE PLACED AT A MAXIMUM INTERVAL OF 4 FEET. THE STAKES SHALL BE DRIVEN TO A MINIMUM DEPTH OF 12 INCHES WITH A MINIMUM OF 3 INCHES PROTRUDING ABOVE THE ROLL. MAINTENANCE NOTES: 1. INSPECT COCONUT FIBER ROLL WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL EVENT (1/2 INCH OR GREATER). 2. REMOVE ACCUMULATED SEDIMENT AND ANY DEBRIS. 3. THE ROLL SHALL BE REPLACED IF CLOGGED OR TORN. 4. THE ROLL SHALL BE REINSTALLED IF UNDERMINED OR DISLODGED. BOARD FENCE SNOW FENCE DRIP LINE PLASTIC FENCE CORD FENCE N.T.S. TREE PROTECTION FENCING2 1. PLACE TREE PROTECTION ZONE (TPZ) BARRIERS TO PREVENT THE APPROACH OF EQUIPMENT WITHIN THE DRIP LINE OF TREES TO BE RETAINED. TEMPORARY TREE PROTECTION FENCING SHOULD BE ERECTED BEFORE CLEARING, DELIVERIES AND OTHER CONSTRUCTION ACTIVITIES BEGIN ON THE SITE. 2. PROHIBIT OR RESTRICT ACCESS TO TPZs. POST "KEEP OUT" SIGNS ON ALL SIDES OF FENCING. DO NOT PLACE EQUIPMENT, CONSTRUCTION MATERIALS, TOPSOIL, OR FILL DIRT WITHIN THE TPZs. 3. DO NOT NAIL BOARDS TO TREES DURING BUILDING OPERATIONS. 4. MONITOR TPZs DURING ALL PHASES OF CONSTRUCTION. 5. DO NOT CUT TREE ROOTS INSIDE THE TREE DRIP LINE. IF A TREE MARKED FOR PRESERVATION IS DAMAGED, REMOVE IT AND REPLACE IT WITH A TREE OF THE SAME OR SIMILAR SPECIES, 2-IN CALIPER OR LARGER, FROM BALLED AND BURLAPED NURSERY STOCK WHEN ACTIVITY IN THE AREA IS COMPLETE. 6. OPTIMIZE TREE HEALTH FOR ALL TREE WITHIN TPZs. ASSIGN A TRAINED CREWMEMBER OR HIRE A PROFESSIONAL TO COMPLETE REGULAR TREE MAINTENANCE TASKS, INCLUDING WATERING, FERTILIZATION, AND MULCHING TO PROTECT TREE ROOTS. CONSULT A TREE PROFESSIONAL FOR ADVICE ON THESE PRACTICES IF NEEDED. DO NOT CHANGE THE SOIL, GRADE, DRAINAGE, OR ACTION WITHOUT PROTECTING TREES THAT ARE TO BE KEPT. 7. ONCE PROJECT IS COMPLETED, TREE PROTECTION FENCING SHOULD BE LEFT UNTIL EROSION & SEDIMENT CONTROLS ARE REMOVED. WHEN TPZ FENCING IS BEING REMOVED, PRUNE ANY DAMAGED TREES AND REPAIR ANY ROOTS THAT MIGHT HAVE BEEN HARMED. COCONUT FIBER ROLL AREA TO BE PROTECTEDFLOW 3-IN 12-IN MIN 2-IN X 2-IN STAKES FLOW 4-FT M A X SECTION GENERAL CONSTRUCTION NOTES: 1. IF LAND DISTURBANCE IS KEPT BELOW 1 ACRE, NO EROSION & SEDIMENT CONTROL PERMITTING IS REQUIRED BY THE STATE OF NORTH CAROLINA. HOWEVER, ALL EROSION & SEDIMENT CONTROL BEST PRACTICES MUST BE IMPLEMENTED ONSITE WHERE APPROPRIATE. 2. NOT ALL EROSION & SEDIMENT CONTROL DETAILS WILL BE USED OR REPRESENT ALL OF THE MEASURES NECESSARY FOR THIS PROJECT. THE CONTRACTOR SHALL IMPLEMENT AS NECESSARY FOR ONSITE CONDITIONS. 3. SILT FENCE SHALL BE PLACED ON ALL DOWNSTREAM SIDES OF ANY EXCAVATION OR FILL THAT MAY RELEASE SEDIMENT INTO A WATERBODY. IF SILT FENCE CAN NOT BE PROPERLY INSTALLED DUE TO SITE CONSTRAINTS COCONUT FIBER ROLLS MAY BE USED IN PLACE. 4. ALL AREAS THAT MUST PUMP SEDIMENT LADEN WATER OFF SITE MUST USE THE APPROPRIATE SIZED FILTER BAG TO CAPTURE ALL SEDIMENT BEFORE RELEASING WATER BACK INTO A WATERBODY. 5. TREE PROTECTION FENCE AND SEDIMENT FENCE MAY BE COMBINED WHERE NECESSARY. 6. TEMPORARY AND PERMANENT SEEDING MAY BE ALTERED TO BETTER SUIT THE MOUNTAIN REGION. ANY CHANGES MUST BE APPROVED BY THE ENGINEER. T=AsFy T=AsFy 2" MIN Ldh D Z Q D NTS VERTICAL CONSTRUCTION JOINT (CJ) IN ENCASEMENT1 MINIMUM REINF. BAR LAP SPLICE LENGTH (IN) BAR SIZE TOP OTHER #3 15 12 #4 20 15 #5 25 19 #6 29 23 #7 43 33 #8 49 37 #9 60 46 #10 74 57 #11 89 68 MINIMUM REINF. BAR DEVELOPMENT LENGTH (IN) BAR SIZE TOP OTHER #3 12 12 #4 15 12 #5 19 15 #6 23 18 #7 33 25 #8 37 29 #9 46 36 #10 57 44 #11 68 53 NOTES: 1.TABULATED VALUES ARE BASED ON UNCOATED GRADE 60 REBAR AND STRUCTURAL CONCRETE WITH SPECIFIED COMPRESSIVE STRENGTH AND 2" MINIMUM COVER. 2.TENSION DEVELOPMENT LENGTHS AND TENSION LAP SPLICE LENGTHS ARE CALCULATED IN ACCORDANCE WITH ACI 12.2.3 AND 12.15, RESPECTIVELY. 3.LAP SPLICE LENGTHS ARE MULTIPLES OF TENSION DEVELOPMENT LENGTHS; CLASS A=1.0*ld AND CLASS B=1.3*ld (ACI 12.15.1). 4.BAR CENTER-TO-CENTER SPACING WAS ASSUMED TO BE GREATER THAN TWICE THE STRUCTURAL CONCRETE COVER PLUS ONE BAR DIAMETER, SO THAT "c" WAS GOVERNED BY STRUCTURAL CONCRETE COVER RATHER THAN BY BAR SPACING. THEREFORE TABULATED VALUES ARE NOT APPLICABLE FOR CENTER-TO-CENTER BAR SPACING LESS THAN 6". 5.TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12 INCHES OF STRUCTURAL CONCRETE CAST BELOW THE BARS. * SIDE COVER MUST BE > 2-IN * END COVER MUST BE > 2-IN MINIMUM END HOOK DEVELOPMENT LENGTH (IN)* BAR SIZE Ldh Q Z D #3 6 4.5 2.5 2.25 #4 7 6 2.5 3 #5 9 7.5 2.5 3.75 #6 10 9 3 4.5 #7 12 10.5 3.5 5.25 #8 14 12 4 6 #9 15 13.5 4.5 9.5 #10 17 15.5 5.5 11 #11 19 17 6 12 STANDARD DEVELOPMENT, LAP SPLICE AND HOOK LENGTHS5 GENERAL NOTES FOR STRUCTURAL CONCRETE: 1.EXCEPT WHERE OTHERWISE SPECIFIED, THESE GENERAL NOTES SHALL APPLY TO THE STRUCTURAL CONCRETE STRUCTURES. 2.STRUCTURAL CONCRETE SHALL CONFORM TO THE CODE REQUIREMENTS FOR ENVIRONMENTAL ENGINEERING STRUCTURAL CONCRETE STRUCTURES, ACI 350-06. 3.STRUCTURAL DESIGN FOR STRUCTURAL CONCRETE AS DEFINED IN SPECIFICATION SECTION 03 30 00 IS BASED UPON STRUCTURAL CONCRETE WITH A COMPRESSIVE STRENGTH OF 4500 PSI AT 28 DAYS AND REINFORCEMENT WITH A MINIMUM YIELD STRENGTH OF 60,000 PSI. 4.STRUCTURAL CONCRETE TESTING SHALL BE IN COMPLIANCE WITH THE FOLLOWING ASTM STANDARDS: C31, C39, C138, C143, C172, C173, AND C231. 5.FOR REINFORCING STEEL (SEE SPEC 03 20 00): a.UNLESS SPECIFIED ON DRAWINGS, FOR MINIMUM DEVELOPMENT (EMBEDMENT) AND LAPPED SPLICE LENGTH, SEE TABLES ON THIS DRAWING. b.VERTICAL REINFORCEMENT SHALL BE CONTINUED ITS DEVELOPMENT (EMBEDMENT) LENGTH INTO THE BASE OF THE ADJOINING SECTION. c.REINFORCEMENT SHALL BE DRILLED AND EPOXY GROUTED INTO STRUCTURAL CONCRETE IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS ONLY AT LOCATIONS SHOWN ON THE DRAWINGS. REBAR DOWELS SHALL BE INSTALLED IN CLEAN, DRY HOLES. d.REINFORCEMENT SHALL HAVE A MINIMUM LENGTH OF 20'-0" BETWEEN SPLICES UNLESS OTHERWISE SHOWN. e.SPLICES SHALL NOT CROSS CONSTRUCTION JOINT (CJ) OR CONTRACTION JOINT (CRJ). 6.FOR REINFORCEMENT DOWEL BARS (SEE SPEC 03 20 00): a.REINFORCEMENT DOWEL BARS SHALL BE 1.128-IN NOMINAL DIAMETER RIBBED STEEL (#9) IN ACCORDANCE WITH ASTM 615 GRADE 60. SEE SPECIFICATIONS FOR MATERIAL. b.PROVIDE TWO COMPONENT SPEED DOWEL SYSTEM TO ASSURE PROPER FIELD POSITIONING AND ALIGNMENT AT SPECIFIED ENCASEMENT/ROCK INTERFACE. c.DOWELS SHALL BE KEPT IN STRAIGHT ALIGNMENT, IN THE ORIENTATION SHOWN, DURING AND SUBSEQUENT TO STRUCTURAL CONCRETE PLACEMENT. d.DOWELS SHALL BE PLACED NO CLOSER THAN 12 INCHES FROM THE INTERSECTION OF ANY JOINTS. e.DOWELS SHALL BE EMENDED IN ROCK AT LEAST 4 FEET AND EMBEDMENT LENGTH IN THE CONCRETE SHALL BE AT LEAST EQUAL TO DEVELOPMENT LENGTH ACCORDING TO TABULATED VALUES UNLESS SPECIFIED ON DRAWINGS. 7.FOR CHAMFERS: a.CHAMFER ALL EXPOSED PROTRUDING CORNERS 3/4-IN UNLESS OTHERWISE SHOWN OR DESIGNATED. 8.CUT OR BEND STEEL REINFORCING BARS AS NECESSARY TO INSTALL DRAIN PIPES. SEE DETAIL 4 ON THIS SHEET. DEVELOPMENT AND LAP SPLICE LENGTHS FOR REINFORCEMENT IN 4500 PSI (MIN) STRUCTURAL CONCRETE NTS PIPE OUTLET REINFORCEMENT4 AVOID CUTTING MAIN BARS FOR 6" PVC PIPE DRAIN PENETRATIONS. ADJUST SPACING OF MAIN BARS BY 1-INCH MAXIMUM TO CLEAR PIPE. TOP OF ROCK SEE NOTE PROVIDE BENT BARS IF NECESSARY 2'-0" TYP NOTE: FOR PIPE OPENINGS LARGER THAN 6" DIAMETER, ADD VERTICAL AND HORIZONTAL BARS TO COMPENSATE FOR CUT BARS OF MAIN REINFORCEMENT AND ADD DIAGONAL BARS AS SHOWN EACH FACE OF WALL. RL J RL J SK K ST R U C T U R A L N O T E S A N D TY P I C A L D E T A I L S 7 OF 16 9.JOINTS a.CONSTRUCTION JOINTS, IDENTIFIED CJ, SHALL BE PROVIDED WHERE SHOWN ON THE DRAWINGS. b.ADDITIONAL CONSTRUCTION JOINTS OR RELOCATION OF CONSTRUCTION JOINTS MAY BE USED SUBJECT TO APPROVAL BY THE ENGINEER. c.6-IN WATERSTOPS REQUIRED ON ALL STRUCTURAL CONCRETE CONTRACTION JOINTS AND CONSTRUCTION JOINTS UNLESS OTHERWISE SHOWN. d.CONSTRUCTION JOINTS SHALL BE AS SHOWN ON THE PLANS. 10.EMBEDDED MATERIALS BEFORE PLACING STRUCTURAL CONCRETE, CARE SHALL BE TAKEN THAT ALL EMBEDDED ITEMS ARE IN POSITION AND SECURELY FASTENED IN PLACE. ANCHOR BOLT LOCATION AND SETTING ARE SHOWN ON THE STRUCTURAL STEEL, MISCELLANEOUS METAL, STRUCTURAL CONCRETE, AND EQUIPMENT DRAWINGS. CONDUITS AND GROUNDING CABLES ARE SHOWN ON THE MANUFACTURER'S DRAWINGS. ALUMINUM EMBEDMENTS OF ANY KIND ARE NOT PERMITTED. ALL PROJECTING WATERSTOPS SHALL BE SUPPORTED AND PROTECTED FROM DAMAGE AND EXPOSURE. 11.NON-WOVEN GEOTEXTILE CALLED OUT ON THIS SHEET REFERS TO NON-WOVEN, POLYPROPYLENE GEOTEXTILE. NON-WOVEN GEOTEXTILE SHALL BE PLACED ON SOIL SIDE OF EVERY CONTRACTION JOINT AND CONSTRUCTION JOINT. NON-WOVEN GEOTEXTILE SHALL EXTEND 1-FT MINIMUM ON EITHER SIDE OF JOINT. NON-WOVEN GEOTEXTILE SHALL BE PLACE ON COARSE AGGREGATE FOR DRAIN PIPE AS SPECIFIED IN DRAWINGS. 18C21024.020 SHEET DE S I G N E D B Y : DR A W N B Y : CH E C K E D B Y : DA T E RE V . \\ G R E E - F S \ P R O J E C T S \ 2 0 1 8 \ G R E E N S B O R O \ 1 8 C 2 1 0 2 4 _ 0 0 _ L A K E _ L U R E _ D A M \ 0 3 - S E P R O D U C T S \ 0 8 - C A D \ D R A W I N G S \ 0 5 - F I N A L _ D E S I G N \ U N D E R D R A I N D E S I G N \ S T R U C T U R A L G E N E R A L N O T E S . D W G © Schnabel Engineering 2023 All Rights Reserved LI C E N S E N U M B E R : C - 2 5 9 9 11 A O A K B R A N C H D R I V E / G R E E N S B O R O , N C / 2 7 4 0 7 Ph o n e : 3 3 6 - 2 7 4 - 9 4 5 6 sc h n a b e l - e n g . c o m LA K E L U R E D A M R E S E R V O I R D R A I N TO W N O F L A K E L U R E RU T H E R F O R D C O U N T Y , N C CH A R L E S M . J O H N S O N , P . E . NO R T H C A R O L I N A P R O F E S S I O N A L E N G I N E E R N O . 0 3 6 1 8 3 DA T E : PROJECT: DATE: FOR BID FEBRUARY 2023 NOT ISSUED FOR CONSTRUCTION DE S C R I P T I O N NLPN 036183 E N EGIN E R ASE L A R O HTOR L O C AR ISESFONA I C H A RLES M . J O H NSON THICKNESS VARIES PER SECTIONS 6" MIN UNO 6-IN RIBBED PVC WATERSTOP AS SPECIFIED. REFER TO OTHER DETAILS THIS SHEET CARRY ALL HORIZONTAL STEEL THROUGH JOINT EXPOSED FACE OF ENCASEMENT THICKNESS VARIES PER SECTIONS 6" MIN UNO CARRY ALL VERTICAL STEEL THROUGH JOINT 6-IN RIBBED PVC WATERSTOP AS SPECIFIED. REFER TO OTHER DETAILS THIS SHEET EXPOSED FACE OF ENCASEMENT NTS HORIZONTAL CONSTRUCTION JOINT (CJ) IN ENCASEMENT2 NTS TYPICAL PVC WATERSTOP3A 6" 3 8" 18" 1/2-IN ID AND 1-IN OD UNLESS SPECIFIED OTHERWISE PROVIDE AT CONTRUCTION (CJ) JOINTS SIKA GREENSTREAK #717 RIBBED CENTERBULB OR APPROVED EQUIVALENT NTS TYPICAL PVC WATERSTOP3BOPTIONAL ONLY AT APPROVED LOCATIONS AT CONSTRUCTION JOINTS (CJ) SIKA GREENSTREAK #783 FLAT RIBBED OR APPROVED EQUIVALENT 18" 3 8" 1 4" NTS SPLIT FLANGE PVC WATERSTOP3C 6" 3 8" 3/8-IN ID AND 5/8-IN OD 3 16" SIKA GREENSTREAK #724 OR APPROVED EQUIVALENT OPTIONAL ONLY AT APPROVED LOCATIONS JOINT INTENTIONALLY ROUGHENED 1/4-IN AMPLITUDE (SEE SPEC 03 30 00) JOINT INTENTIONALLY ROUGHENED TO 1/4-IN AMPLITUDE (SEE SPEC 03 30 00) o o 2+ 0 0 3+ 0 0 91 0 910 904 902 90 0 898 896 89 4 908 912 89 2 890 888 886 884 88 2 8 8 2 S BAY 6 BAY 5 BAY 4 BROAD RIVER WITHOUT TURBINES GENERATING EL 886.0 ± WITH TURBINE 2 ONLY GENERATING EL 889.7 ± GENERAL SEQUENCE OF REPLACING SEWER LINE 1.DISCONNECT EXISTING BLOW OFF LINE FROM EXISTING SEWER LINE. 2.INSTALL TEMPORARY BYPASS AT THE EXISTING BLOW OFF LOCATION THAT DISCHARGES INTO THE WET WELL OF THE LIFT STATION. 3.INSTALL A PIPE PLUG IN THE SEWER LINE THROUGH THE EXISTING ACCESS PORT. 4.REMOVE EXISTING SEWER AND APPURTENANCES (MANHOLE, JUNCTION BOX, PUMP STATION, VALVE, ETC.) BETWEEN THE ACCESS PORT ALL THE WAY DOWN TO THE LEFT SIDE OF THE RIVER CROSSING. 5.INSTALL NEW SEWER LINE THAT IS ROUTED UNDERNEATH THE PROPOSED RESERVOIR DRAIN ENCASEMENT/JET FLOW GATE VALVE AND RECONNECT TO THE EXISTING PIPE AT THE RIVER CROSSING. CONNECTIONS BETWEEN THE EXISTING SEWER LINE (CIP) AND REPLACEMENT SEWER LINE (DIP) SHOULD BE MADE USING COMPATIBLE MEGA-LUG CONNECTIONS. PIPE JOINTS FOR REPLACEMENT SEWER LINE SHALL BE RESTRAINED (RJ). INSTALL VERTICAL 18-IN TEES WITH PLUGGED BRANCH (RJ) AT LOCATIONS SHOWN. 6.REMOVE THE PIPE PLUG AND TEMPORARY BYPASS. N 18C21024.020 SHEET DE S I G N E D B Y : DR A W N B Y : CH E C K E D B Y : DA T E RE V . \\ G R E E - F S \ P R O J E C T S \ 2 0 1 8 \ G R E E N S B O R O \ 1 8 C 2 1 0 2 4 _ 0 0 _ L A K E _ L U R E _ D A M \ 0 3 - S E P R O D U C T S \ 0 8 - C A D \ D R A W I N G S \ 0 5 - F I N A L _ D E S I G N \ U N D E R D R A I N D E S I G N \ S I T E P L A N A N D D E T A I L S . D W G © Schnabel Engineering 2023 All Rights Reserved LI C E N S E N U M B E R : C - 2 5 9 9 11 A O A K B R A N C H D R I V E / G R E E N S B O R O , N C / 2 7 4 0 7 Ph o n e : 3 3 6 - 2 7 4 - 9 4 5 6 sc h n a b e l - e n g . c o m LA K E L U R E D A M R E S E R V O I R D R A I N TO W N O F L A K E L U R E RU T H E R F O R D C O U N T Y , N C CH A R L E S M . J O H N S O N , P . E . NO R T H C A R O L I N A P R O F E S S I O N A L E N G I N E E R N O . 0 3 6 1 8 3 DA T E : PROJECT: DATE: FOR BID FEBRUARY 2023 NOT ISSUED FOR CONSTRUCTION DE S C R I P T I O N NLPN 036183 E N EGIN E R ASE L A R O HTOR L O C AR ISESFONA I C H A RLES M . J O H NSON SE W E R L I N E R E P L A C E M E N T PL A N 00 10'20' SCALE: 1"=10' SEWER LINE REPLACEMENT PLAN1 FLOW SK CM J SK EXISTING 18-IN DIA DIP SEWER LINE THROUGH DAM EXISTING SEWER LINE BLOW OFF VALVE TO REMAIN 18-IN DIA DIP SEWER LINE (RJ) EXISTING 18-IN DIA CIP SEWER LINE TO BE DEMOLISHED EXISTING PUMP STATION TO BE DEMOLISHED EXISTING SEWER LINE ACCESS PORT AND TEMPORARY PIPE PLUG EXISTING 6-IN DIA PVC BLOW OFF LINE TO BE REMOVED FROM BLOW OFF VALVE TO DOWNSTREAM END BAY 7 EXISTING CONCRETE SLAB TO BE DEMOLISHED EXISTING JUNCTION BOX TO BE DEMOLISHED EXISTING MANHOLE TO BE DEMOLISHED CONNECT EXISTING SEWER LINE (CIP) AND REPLACEMENT SEWER LINE (DIP) WITH COMPATIBLE MEGA-LUG CONNECTION EXISTING THRUST BLOCK EXISTING STARTER BLOCK C BAY 5 AND DRAIN PIPE (NOT SHOWN)L GENERAL NOTES 1.EXISTING STRUCTURE IS BASED ON SURVEY PERFORMED BY ED HOLMES AND ASSOCIATES LAND SURVEYORS, PA DATED JANUARY 9TH, 2019. 2.THE SURVEY VERTICAL DATUM IS BASED ON NAVD 88. 3.CONTRACTOR SHALL FIELD VERIFY DIMENSIONS NECESSARY FOR FIT-UP OF NEW CONSTRUCTION COMPONENTS TO EXISTING FEATURES. TOP EL 891.6 TOP EL 891.7 TOP EL 892.4 8 OF 16 10.4° 23.1' 137.8' 3.6' 21.5° EXISTING SEWER LINE SUPPORT PIER SECURE REPLACEMENT SEWER LINE TO COMPETENT ROCK BELOW. PROVIDE PIERS FOR SUPPORT PER DETAILS 2 AND 3 ON SHEET 9. DAM/BRIDGE CENTER LINE AWWA C110 18- IN DIA DUCTILE IRON PIPE (RJ) CONNECT EXISTING SEWER LINE (CIP) AND REPLACEMENT SEWER LINE (DIP) WITH COMPATIBLE MEGA-LUG CONNECTION TOP EL 891.85 VERTICAL 18-INCH TEE WITH PLUGGED BRANCH - ALL RJ, TYP. - SEE DETAIL 4 ON SHEET 9 VERTICAL 18-INCH TEE WITH PLUGGED BRANCH - ALL RJ, TYP. - SEE DETAIL 4 ON SHEET 9 904 902 90 0 898 896 89 4 908 89 2 890 888 886 N 18C21024.020 SHEET DE S I G N E D B Y : DR A W N B Y : CH E C K E D B Y : DA T E RE V . \\ G R E E - F S \ P R O J E C T S \ 2 0 1 8 \ G R E E N S B O R O \ 1 8 C 2 1 0 2 4 _ 0 0 _ L A K E _ L U R E _ D A M \ 0 3 - S E P R O D U C T S \ 0 8 - C A D \ D R A W I N G S \ 0 5 - F I N A L _ D E S I G N \ U N D E R D R A I N D E S I G N \ S I T E P L A N A N D D E T A I L S . D W G © Schnabel Engineering 2023 All Rights Reserved LI C E N S E N U M B E R : C - 2 5 9 9 11 A O A K B R A N C H D R I V E / G R E E N S B O R O , N C / 2 7 4 0 7 Ph o n e : 3 3 6 - 2 7 4 - 9 4 5 6 sc h n a b e l - e n g . c o m LA K E L U R E D A M R E S E R V O I R D R A I N TO W N O F L A K E L U R E RU T H E R F O R D C O U N T Y , N C CH A R L E S M . J O H N S O N , P . E . NO R T H C A R O L I N A P R O F E S S I O N A L E N G I N E E R N O . 0 3 6 1 8 3 DA T E : PROJECT: DATE: FOR BID FEBRUARY 2023 NOT ISSUED FOR CONSTRUCTION DE S C R I P T I O N NLPN 036183 E N EGIN E R ASE L A R O HTOR L O C AR ISESFONA I C H A RLES M . J O H NSON BA Y 5 E N C A S E M E N T P L A N & SE W E R L I N E C R A D L E 00 10'20' SCALE: 1"=10' BAY 5 ENCASEMENT PLAN1 FLOW VS CM J VS EXISTING 18-IN DIA DIP SEWER LINE THROUGH DAM EXISTING THRUST BLOCK BELOW GENERAL NOTES 1.EXISTING STRUCTURE IS BASED ON SURVEY PERFORMED BY ED HOLMES AND ASSOCIATES LAND SURVEYORS, PA DATED JANUARY 9TH, 2019. 2.THE SURVEY VERTICAL DATUM IS BASED ON NAVD 88. 3.CONTRACTOR SHALL FIELD VERIFY DIMENSIONS NECESSARY FOR FIT-UP OF NEW CONSTRUCTION COMPONENTS TO EXISTING FEATURES. 9 OF 16 1 12 2 12 9.0'30.0'35.0'32.5' 18.0'19.0' 1 10&11 GUARD VALVE RESERVOIR DRAIN PIPE CONCRETE ENCASEMENT EXISTING BUTTRESS EXISTING ARCH EXISTING BUTTRESS JET FLOW GATE VALVE SLOPE DOWN SLOPE DOWN EXISTING BRIDGE ABOVE 6-IN PVC PIPE, NO SLOTS 6" DIA SLOTTED PVC PIPE SEE SHEET 12 6.67' NTS SEWER LINE PIER SUPPORT2 TOTAL HEIGHT VARIES MINIMUM 3.8 FEET FOR ABOVEGROUND SUPPORT 1/2" X 3" STAINLESS STEEL STRAP WITH 1/2" X 3" NEOPRENE PAD ADHERED TO STRAP 3/4" Ø X 4 1/2" MIN EFFECTIVE EMBEDMENT STAINLESS STEEL POST-INSTALLED EXPANSION ANCHOR BOLT, HILTI KWIK BOLT TZ2 OR APPROVED EQUIVALENT, TYP 18-IN DIA DIP SEWER LINE NTS SEWER LINE PIER SUPPORT3 1/2" X 3" STAINLESS STEEL STRAP WITH 1/2" X 3" NEOPRENE PAD ADHERED TO STRAP 18-IN DIA DIP SEWER LINE 1 5 CONCRETE PIER AT 20' OC MAX, LOCATE ONE PIER WITHIN 2 FEET OF ANY PIPE BENDS AND PIPE JOINTS EXCAVATE TO COMPETENT ROCK AS DETERMINED BY THE ENGINEER 112" 3'-6" 1'-0" 3" 6-IN PVC PIPE, NO SLOTS EXISTING STARTER BLOCK BELOW 3" CLR TYP 3" CLR TYP 3#5 4#5 OMIT TOP, CENTER BAR TO AVOID CONFLICT WITH ANCHOR BOLTS 3" CLR VERTICAL CLEANOUT SEE SHEET 14 1.00' NTS SEWER LINE VERTICAL TEE CLEANOUT4 18-IN DIA DIP SEWER LINE (RJ)18-IN DIA DIP SEWER LINE (RJ) 18-IN DIA DIP SEWER LINE (RJ) WITH THREADED CAP 18-IN DIP VERTICAL TEE FLANGED FITTING 18-IN DUCTILE IRON REMOVABLE PLUG 12-IN MIN RESERVOIR DRAIN PIPE EXCAVATE TO COMPETENT ROCK AS DETERMINED BY THE ENGINEER 1/2" THICK NEOPRENE PAD, PROVIDE WIDTH OF PIER RESERVOIR DRAIN PIPE - FILL BYPASS RESERVOIR DRAIN PIPE - DRAIN VACUUM VALVE EL E V A T I O N ( F E E T ) 870 880 890 900 910 920 930 940 950 960 970 980 990 1000 1010 1020 870 880 890 900 910 920 930 940 950 960 970 980 990 1000 1010 1020 01020304050607080901001101201301401501600 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 LAKE LURE EXISTING SEDIMENT TO BE CLEANED OFF OF DAM AS NECESSARY TO FACILITATE RESERVOIR DRAIN AND TRASH RACK INSTALLATION NORMAL WATER SURFACE EL 990.0 ± UPSTREAM FACE OF EXISTING ARCH EXISTING THRUST BLOCK BEYOND EXISTING GRADE AT SECTION (BAY CENTERLINE) EXISTING CORBEL BEYOND EXISTING BUTTRESS BEYOND (TAPERED ON SIDES) CREST OF EXISTING ROAD EL 1002.44 APPROXIMATE EXISTING LIFT LINE LOCATION, TYP. 18-IN DIA DIP SEWER LINE EXISTING GRADE AT BUTTRESS BEYOND GROUT AROUND PIPE AFTER INSTALLATION STEEL BULKHEAD SEE DETAIL 1 ON SHEET 15 PRECAST CONCRETE PORTAL SEE DETAILS 1 THROUGH 4 ON SHEET 13 72-IN DIA WELDED STEEL PIPE INVERT EL 892.8 ± 1 1 C OF RESERVOIR DRAIN PIPE AT DOWNSTREAM FACE OF ARCH EL 904.5 CONCRETE ENCASEMENT L FOUR-MITER 45 DEG BEND SEE DETAIL 1 ON SHEET 14 EL 891.5 ± 2.75' 8.5' SQUARE 9.25'16.75' 11.0'±3.5' 22.7' 12.5' TRASH RACK OUTLINE SEE DETAIL 2 ON SHEET 15 8.5' 6.18' PHASE 2 CONCRETE PHASE 1 CONCRETE R9.0' 1.92' BUSH HAMMER 2-FT STRIP ON DOWNSTREAM FACE OF ARCH ALL AROUND CUT 2' 1'-6" GENERAL NOTES 1.PROPOSED FOUNDATION GRADE LOCATED BELOW RESERVOIR DRAIN TO BE COMPETENT ROCK AS DETERMINED IN FIELD BY ENGINEER. 2.EXISTING STRUCTURE IS BASED ON SURVEY PERFORMED BY ED HOLMES AND ASSOCIATES LAND SURVEYORS, PA DATED JANUARY 9TH, 2019. 3.THE SURVEY VERTICAL DATUM IS BASED ON NAVD 88. 4.CONTRACTOR SHALL FIELD VERIFY DIMENSIONS AND ELEVATIONS NECESSARY FOR FIT-UP OF NEW CONSTRUCTION COMPONENTS TO EXISTING FEATURES. 18C21024.020 SHEET DE S I G N E D B Y : DR A W N B Y : CH E C K E D B Y : DA T E RE V . \\ G R E E - F S \ P R O J E C T S \ 2 0 1 8 \ G R E E N S B O R O \ 1 8 C 2 1 0 2 4 _ 0 0 _ L A K E _ L U R E _ D A M \ 0 3 - S E P R O D U C T S \ 0 8 - C A D \ D R A W I N G S \ 0 5 - F I N A L _ D E S I G N \ U N D E R D R A I N D E S I G N \ S I T E P L A N A N D D E T A I L S . D W G © Schnabel Engineering 2023 All Rights Reserved LI C E N S E N U M B E R : C - 2 5 9 9 11 A O A K B R A N C H D R I V E / G R E E N S B O R O , N C / 2 7 4 0 7 Ph o n e : 3 3 6 - 2 7 4 - 9 4 5 6 sc h n a b e l - e n g . c o m LA K E L U R E D A M R E S E R V O I R D R A I N TO W N O F L A K E L U R E RU T H E R F O R D C O U N T Y , N C CH A R L E S M . J O H N S O N , P . E . NO R T H C A R O L I N A P R O F E S S I O N A L E N G I N E E R N O . 0 3 6 1 8 3 DA T E : PROJECT: DATE: FOR BID FEBRUARY 2023 NOT ISSUED FOR CONSTRUCTION DE S C R I P T I O N NLPN 036183 E N EGIN E R ASE L A R O HTOR L O C AR ISESFONA I C H A RLES M . J O H NSON 00 10'20' SCALE: 1"=10' BAY 5 SECTION - STRUCTURAL PHASE 11 10 10 OF 16 FLOW SK SK CM J RESERVOIR DRAIN GENERAL CONSTRUCTION SEQUENCE - PHASE 1 1.INSTALL EROSION AND SEDIMENT CONTROL MEASURES AND TEMPORARY ENVIRONMENTAL CONTROLS AS NEEDED. 2.CREATE ACCESS FOR CONSTRUCTION IN BAY 5, INCLUDING CONSTRUCTION OF THE RIVER CROSSING. RELOCATE BOULDERS AS NECESSARY TO FACILITATE CONSTRUCTION ACCESS AND CREATE A SURFACE WATER DIVERSION AROUND THE WORK AREA. 3.DEMOLISH THE EXISTING SANITARY SEWER LIFT STATION AND OTHER SANITARY SEWER APPURTENANCES IN BAY 5 AS SHOWN ON THE DRAWINGS. 4.RELOCATE AND REPLACE THE PORTION OF THE EXISTING SANITARY SEWER LINE AS SHOWN ON THE DRAWINGS. 5.EXCAVATE DOWNSTREAM SUBGRADE WITHIN BAY 5 TO EXPOSE COMPETENT ROCK AS APPROVED BY THE ENGINEER, AS SHOWN OF THE CONCRETE ENCASEMENT. PROTECT AND SUPPORT THE RELOCATED SANITARY SEWER LINE AS NEEDED. 6.LOCATE THE RESERVOIR DRAIN CENTER AT THE CENTER OF THE DOWNSTREAM SIDE OF THE ARCH AND DRILL A ONE-INCH DIA HOLE THROUGH THE ARCH TO DETERMINE THE CENTER OF THE DRAIN ON THE UPSTREAM FACE OF THE DAM. CONTRACTOR SHALL PROVIDE APPROPRIATE TOOLS FOR DRILLING INTO A FULL HEAD RESERVOIR AND ADEQUATELY SEAL PENETRATION. EITHER LEAVE THE DRILL ROD PROTRUDING OR INSTALL A ROD PROJECTING THROUGH THE HOLE AND SECURE ON THE DOWNSTREAM FACE. 7.POUR FIRST SECTION OF REINFORCED CONCRETE ENCASEMENT TO EXTENTS SHOWN, LEAVING 8'-6” SQUARE BLOCK-OUT INSIDE THE ENCASEMENT FOR PENETRATION THROUGH ARCH. PLACE GROUT TUBES TO BE INJECTED IN THE AREA BETWEEN THE ENCASEMENT AND ARCH TO ENSURE A TIGHT SEAL AND FULL BEARING. 8.INSTALL THE PRECAST REINFORCED CONCRETE PORTAL ON THE UPSTREAM FACE OF THE ARCH CENTERED WITH THE PROJECTING ROD VIA DIVER ACCESS. SEE SHEET 15. 8.1.SECURE THE PORTAL BY DRILLING ANCHORS THROUGH THE PERIMETER LOCATIONS PROVIDED AND ANCHOR TO THE FACE OF THE DAM. 8.2.SEAL THE INSIDE AND OUTSIDE PERIMETER OF THE PORTAL COLLAR WITH AN UNDERWATER EPOXY OR GROUT SUCH AS SPLASH ZONE OR APPROVED EQUIVALENT. 8.3.GROUT THE CONTACT ZONE OF THE PORTAL ON THE DAM FACE THROUGH THE LOWER PORTAL PORT WITH A NON-SHRINK UNDERWATER GROUT UNTIL RETURN IS CONSISTENT AT BOTH UPSTREAM PORTS. 8.4.INSTALL STEEL BULKHEAD ON THE CONCRETE PORTAL. 9.REMOVE THE ROD FROM THE DOWNSTREAM SIDE OF THE ARCH, CONFIRM THE CONCRETE PORTAL AND STEEL BULKHEAD ARE SEALED TO THE ARCH, AND DRILL AN 18-INCH DIA HOLE THROUGH THE ARCH CENTERED WITH ONE-INCH DIA HOLE. 10.DRILL EIGHT PERIMETER HOLES FOR WIRE SAWING THE OCTAGONAL OPENING PATTERN AS SHOWN IN DETAIL 1 ON SHEET 13. 11.INSTALL THE 72-IN DIA WELDED STEEL PIPE. 12.INSTALL THE 6-IN DIA SEAMLESS STEEL BYPASS PIPE AS SPECIFIED IN SHEET 14, DETAIL 5. 13.WELD THE PIPE JOINTS AS SPECIFIED IN SHEET 14. 14.GROUT THE ANNULUS BETWEEN THE PIPE, PRECAST CONCRETE PORTAL, DAM, AND CONCRETE ENCASEMENT. 15.INSTALL STEEL TRASH RACK AND JACK SCREW FOR LIFTING THE BULKHEAD. DRILL AND GROUT ANCHORS TO EXISTING ARCH PER SHEETS 15 AND 16. 16.SEE SHEET 11 FOR STRUCTURAL PHASE 2 OF RESERVOIR DRAIN CONSTRUCTION. ST R U C T U R A L P H A S E 1 - SE C T I O N DOWNSTREAM FACE OF EXISTING ARCH EXCAVATE TO COMPETENT ROCK, DO NOT UNDERMINE EXISTING STRUCTURES 6-IN DIA PVC DRAIN PIPE, SEE DETAIL 3 ON SHEET 12 6" PIPE FOR FILL BYPASS EL E V A T I O N ( F E E T ) 870 880 890 900 910 920 930 940 950 960 970 980 990 1000 1010 1020 870 880 890 900 910 920 930 940 950 960 970 980 990 1000 1010 1020 01020304050607080901001101201301401501600 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 LAKE LURE PROPOSED GRADE, EXCAVATE TO ROCK (SEE GENERAL NOTE 1) NORMAL WATER SURFACE EL 990.0 ± UPSTREAM FACE OF EXISTING ARCH EXISTING THRUST BLOCK BEYOND EXISTING CORBEL BEYOND EXISTING BUTTRESS BEYOND (TAPERED ON SIDES) CREST OF EXISTING ROAD EL 1002.44 APPROXIMATE EXISTING LIFT LINE LOCATION, TYP. LAKE LURE CONCRETE CRADLE FOR PIPE BEND BUILT UP TO CENTER LINE OF PIPE (180°) CONSTRUCTION JOINT, TYP 9.0' DRESSER COUPLING 60-IN JET FLOW GATE VALVE SUPPORTS TO CONCRETE ENCASEMENT BY VALVE AND ACTUATOR MANUFACTURERS 72-IN KNIFE GATE VALVE, CONNECT TO PIPE WITH AWWA CLASS D FLANGE. SEE VALVE SPEC. PROVIDE ACCESS PLATFORM MIN OF 3' X 4' AROUND KNIFE GATE TO SERVICE OPERATOR. PIPE INVERT EL 893.0± EL 895 ± 22.5° 30.0'35.0'10.0' 3.5' 2.0' 18-IN DIA DIP SEWER PIPE THREE-MITER 22.5 DEG BEND SEE DETAIL 3 ON SHEET 14 16.75' 4.0' 40.0'40.0' 8.0' 20.0' 3.0' 32.5' PHASE 2 CONCRETE PHASE 1 CONCRETE R9.0' JET FLOW GATE VALVE CONNECTED TO PIPE USING AWWA CLASS D FLANGE, SEE VALVE SPEC 1.92' 2' 1'-6" 18C21024.020 SHEET DE S I G N E D B Y : DR A W N B Y : CH E C K E D B Y : DA T E RE V . \\ G R E E - F S \ P R O J E C T S \ 2 0 1 8 \ G R E E N S B O R O \ 1 8 C 2 1 0 2 4 _ 0 0 _ L A K E _ L U R E _ D A M \ 0 3 - S E P R O D U C T S \ 0 8 - C A D \ D R A W I N G S \ 0 5 - F I N A L _ D E S I G N \ U N D E R D R A I N D E S I G N \ S I T E P L A N A N D D E T A I L S . D W G © Schnabel Engineering 2023 All Rights Reserved LI C E N S E N U M B E R : C - 2 5 9 9 11 A O A K B R A N C H D R I V E / G R E E N S B O R O , N C / 2 7 4 0 7 Ph o n e : 3 3 6 - 2 7 4 - 9 4 5 6 sc h n a b e l - e n g . c o m LA K E L U R E D A M R E S E R V O I R D R A I N TO W N O F L A K E L U R E RU T H E R F O R D C O U N T Y , N C CH A R L E S M . J O H N S O N , P . E . NO R T H C A R O L I N A P R O F E S S I O N A L E N G I N E E R N O . 0 3 6 1 8 3 DA T E : PROJECT: DATE: FOR BID FEBRUARY 2023 NOT ISSUED FOR CONSTRUCTION DE S C R I P T I O N NLPN 036183 E N EGIN E R ASE L A R O HTOR L O C AR ISESFONA I C H A RLES M . J O H NSON ST R U C T U R A L P H A S E 2 - SE C T I O N 00 10'20' SCALE: 1"=10' BAY 5 SECTION - STRUCTURAL PHASE 21 11 11 OF 16 FLOW SK SK CM J RESERVOIR DRAIN GENERAL CONSTRUCTION SEQUENCE PHASE 2 1.PLACE CONCRETE FOUNDATION BLOCK UNDER 72-IN KNIFE GATE VALVE. 2.INSTALL AND ANCHOR 72-IN KNIFE GATE VALVE. 3.INSTALL TWO 6-IN DIA PVC DRAIN PIPE CONNECTING TWO SIDES OF CONCRETE ENCASEMENT (CROSS CANYON) AT SHOWN LOCATIONS, INVERT EL 891.5. NOTE THAT THE SPECIFIED ELEVATION MAY BE CHANGED, DEPENDING ON THE ELEVATION OF COMPETENT ROCK LEVEL. 4.PLACE CONCRETE FOUNDATION UNDER THE HORIZONTAL PORTION OF THE PIPE. 5.INSTALL THE HORIZONTAL PORTION OF THE PIPE. WELD THE SPECIFIED PIPE JOINT AS SHOWN IN SHEET 14. 6.INSTALL 6" BYPASS GATE VALVE AND PIPING AS SHOWN IN SHEET 14, DETAIL 5. 7.INSTALL 6" DRAIN GATE VALVE AND PIPING AS SHOWN IN SHEET 12. 8.INSTALL 2" AIR/VACUUM RELIEF VALVE. 9.PLACE CONCRETE TO ENCASE THE PIPE. 10.PLACE THE CONCRETE FOUNDATION FOR JET FLOW GATE VALVE AND ENCASEMENT FOR SEWAGE PIPE. 11.INSTALL THE DOWNSTREAM BENT SECTIONS OF THE PIPE AND POUR CONCRETE CRADLE AROUND THE BEND. INSTALL PIPE STRAP ON THE UNCONFINED PART OF PIPE AS SHOWN IN SHEET 13. 12.INSTALL AND ANCHOR JET FLOW GATE VALVE. 13.PROVIDE PERMANENT ACCESS PLATFORMS FOR MAINTENANCE OF GATE, KNIFE GATE, AND JET FLOW GATE VALVES PER SPECIFICATIONS. ENGINEER SHALL APPROVE PLATFORM DETAIL BEFORE CONSTRUCTION. 14.CLOSE KNIFE GATE VALVE AND 6" DRAIN GATE VALVE (NOT SHOWN, SHEET 14). 15.OPEN THE BULKHEAD FILL VALVE TO EQUALIZE THE PRESSURE IN THE PIPE AND THE RESERVOIR. 16.WITH SATISFACTORY LEAKAGE OF THE KNIFE GATE VALVE, LIFT THE BULKHEAD ON ITS HINGES AND SECURE IN THE OPEN POSITION. 17.OPEN 6" KNIFE GATE VALVE BYPASS TO EQUALIZE PRESSURE BETWEEN KNIFE GATE VALVE AND JET FLOW GATE VALVE. 18.CONDUCT START-UP PROCEDURES FOR BOTH VALVES PER THE SPECIFICATIONS. TBD BY VALVE MANUFACTURER CONTRACTOR COORDINATE GENERAL NOTES 1.PROPOSED FOUNDATION GRADE LOCATED BELOW RESERVOIR DRAIN TO BE COMPETENT ROCK AS DETERMINED IN FIELD BY ENGINEER. 2.EXISTING STRUCTURE IS BASED ON SURVEY PERFORMED BY ED HOLMES AND ASSOCIATES LAND SURVEYORS, PA DATED JANUARY 9TH, 2019. 3.THE SURVEY VERTICAL DATUM IS BASED ON NAVD 88. 4.CONTRACTOR SHALL VERIFY DIMENSIONS REQUIRED FOR VALVE FIT-UP AND SUPPORT WITH VALVE MANUFACTURER. 5.WELDING ELECTRODE SHALL BE E70 WITH DEEP PENETRATION. BASE OF EXISTING ARCH DOWNSTREAM FACE OF EXISTING ARCH 5 13 BULKHEAD HINGE 2 12 23°' 6" DIA PVC PIPE PROVIDE ACCESS PLATFORM MIN OF 3' X 4' UPSTREAM SIDE OF JET FLOW GATE VALVE6" PIPE FOR BYPASS 6" GATE VALVE, PROVIDE SUPPORT PIPE SUPPORT ON BOTH SIDES OF VALVE 2" AIR/VACUUM RELIEF VALVE TO TOP OF PIPE SPOOL 6" DIA STEEL DRAIN PIPE 1" BALL VALVE AND PRESSURE GAUGE, BOTH SIDES OF VALVE 4'-0" 3" CLR, TYP 9" 3'-0" 3'-6" 3'-6" 3'-6"3'-6"3'-6"2'-6"2'-6"2'-6"2'-6"3'-6"3'-6"3'-6" 9#5 (GALV) 9#9 (GALV)9#9 (GALV) 1 1 18C21024.020 SHEET DE S I G N E D B Y : DR A W N B Y : CH E C K E D B Y : DA T E RE V . \\ G R E E - F S \ P R O J E C T S \ 2 0 1 8 \ G R E E N S B O R O \ 1 8 C 2 1 0 2 4 _ 0 0 _ L A K E _ L U R E _ D A M \ 0 3 - S E P R O D U C T S \ 0 8 - C A D \ D R A W I N G S \ 0 5 - F I N A L _ D E S I G N \ U N D E R D R A I N D E S I G N \ E N C A S E M E N T D E T A I L S . D W G © Schnabel Engineering 2023 All Rights Reserved LI C E N S E N U M B E R : C - 2 5 9 9 11 A O A K B R A N C H D R I V E / G R E E N S B O R O , N C / 2 7 4 0 7 Ph o n e : 3 3 6 - 2 7 4 - 9 4 5 6 sc h n a b e l - e n g . c o m LA K E L U R E D A M R E S E R V O I R D R A I N TO W N O F L A K E L U R E RU T H E R F O R D C O U N T Y , N C CH A R L E S M . J O H N S O N , P . E . NO R T H C A R O L I N A P R O F E S S I O N A L E N G I N E E R N O . 0 3 6 1 8 3 DA T E : PROJECT: DATE: FOR BID FEBRUARY 2023 NOT ISSUED FOR CONSTRUCTION DE S C R I P T I O N NLPN 036183 E N EGIN E R ASE L A R O HTOR L O C AR ISESFONA I C H A RLES M . J O H NSONCONCRETE ENCASEMENT SECTION1 12 00 4'8' SCALE: 1/4"=1'0" CO N C R E T E E N C A S E M E N T DE T A I L S SK SK CM J 12 OF 16 PIPE ENCASEMENT SECTION2 12 00 4'8' SCALE: 1/4"=1'0" CONCRETE ENCASEMENT SECTION3 12 00 4'8' SCALE: 1/4"=1'0" REBAR DOWELS AT EXISTING STARTER BLOCK4 12 00 4'8' SCALE: 1/4"=1'0" R9'-0" 2'-9" 4'-3" 4'-3" 5'-6" 8'-6"EQ EQ 4'-0" TYP 4 ROWS OF #9@5' (GALV) SEE DETAIL 5 ON THIS SHEET HYDROPHILIC WS AROUND PIPE 2'-0" LAP 2'-0" LAP 2'-0"2'-0" HYDROPHILIC WS EXTENDED TO 6-IN BELOW TOP OF SIDE COARSE AGGREGATE BACKFILL HYDROPHILIC WS 6-IN DIA SLOTTED PVC DRAIN #5@12" (GALV) 6" NCDOT #78M COARSE AGGREGATE ENCLOSED BY NON-WOVEN GEOTEXTILE EXCEPT BOTTOM SIDE 6" DIA PVC PIPE, NO SLOTS, GEOTEXTILE, AND DRAINAGE COARSE AGGREGATE 6-IN DIA PVC T-FITTING 1 1 4'-0"#9@10' (GALV) 2'-0" 1'-0" 6" GENERAL NOTES 1.PROPOSED FOUNDATION GRADE LOCATED BELOW RESERVOIR DRAIN TO BE AT COMPETENT ROCK TO BE DETERMINED IN FIELD BY ENGINEER. 2.EXISTING STRUCTURE IS BASED ON SURVEY PERFORMED BY ED HOLMES AND ASSOCIATES LAND SURVEYORS, PA DATED JANUARY 9TH, 2019. 3.THE SURVEY VERTICAL DATUM IS BASED ON NAVD 88. 4.CONTRACTOR SHALL FIELD VERIFY DIMENSIONS AND ELEVATIONS. 6'-8"6" 2'-0" TYP #5@12" EW, TYP AT HORIZONTAL LIFT LINES #5@8" TYP AROUND 72-IN PIPE #6@6" TYP AT EXPOSED SURFACES #9 (GALV), TYP 2'-6" #6@6" TYP AT EXPOSED SURFACES #5@8" 6" DIA PVC DRAIN PIPE OUTLET #5@12" #5@8" #5@8" HYDROPHILIC WS EXTENDED AROUND ARCH SURFACE TO BUTTRESS SURFACES HYDROPHILIC WS EXTENDED INTO COARSE AGGREGATE BACKFILL HYDROPHILIC WS AROUND PIPE SEE DETAIL 6 ON SHEET 13 COARSE AGGREGATE BACKFILL BOTH SIDES OF ENCASEMENT TO EL 891 2'-0" TRASH RACK NOT SHOWN FOR CLARITY 1 & 2 13 4 13 TOP OF ROCK UNKNOWN, FOUNDATION EXCAVATION SHALL BE APPROVED BY THE ENGINEER. LEVELING CONCRETE MAY BE REQUIRED FOR FOUNDATION. 6'-3" 1'-113 4" WS SEWER PIPE WITH SUPPORTS PER DETAILS 2 AND 3 ON SHEET 9 2'-0" LAP, TYP 3" CLR GROUT TOP OF ROCK UNKNOWN 10'-0" 6" 7'-0" 4'-3" TOP OF ROCK UNKNOWN 4 12 EXISTING STARTER BLOCK REBAR DOWEL PER DETAIL 4 ON THIS SHEET, DRILL AND EPOXY 4'-0" MIN INTO EXISTING CONCRETE, TYP 16'-9" #6@6" TYP AT EXPOSED SURFACES REBAR DOWEL DETAIL5 12 00 2'4' SCALE: 1/2"=1'0" CENTRALIZERS AT 2-FT OC 3" MIN DIA DRILL HOLE GROUT TOP OF ROCK ACI STANDARD 90-DEGREE HOOK #9 REBAR DOWEL (GALV) PER ENCASEMENT DETAILS HIGH POINT OF STARTER BLOCK AT UPSTREAM EDGE WHERE ABUTS DOWNSTREAM FACE OF ARCH DIMENSIONS ALONG SLOPED FACE OF STARTER BLOCK 4'-0" MIN 8" 1'-1" 8'-0"10'-0"8'-0" 5'-0"5'-0"5'-0"2'-6" 2'-6" 5'-0" 5'-0" 5'-0" 8'-0"10'-0"8'-0"EQ EQ HORIZ DIMENSIONS 6-IN PVC VERTICAL CLEANOUT SEE SHEET 14 ANCHORS PER DETAILS 3 AND 4 ON THIS SHEET 2'-0" 6-IN GATE VALVE 6-IN SEAMLESS STEEL PIPE, KNIFE GATE BYPASS 6-IN GATE VALVE 6-IN SEAMLESS STEEL DRAIN PIPE 10'-6" 18C21024.020 SHEET DE S I G N E D B Y : DR A W N B Y : CH E C K E D B Y : DA T E RE V . \\ G R E E - F S \ P R O J E C T S \ 2 0 1 8 \ G R E E N S B O R O \ 1 8 C 2 1 0 2 4 _ 0 0 _ L A K E _ L U R E _ D A M \ 0 3 - S E P R O D U C T S \ 0 8 - C A D \ D R A W I N G S \ 0 5 - F I N A L _ D E S I G N \ U N D E R D R A I N D E S I G N \ E N C A S E M E N T D E T A I L S . D W G © Schnabel Engineering 2023 All Rights Reserved LI C E N S E N U M B E R : C - 2 5 9 9 11 A O A K B R A N C H D R I V E / G R E E N S B O R O , N C / 2 7 4 0 7 Ph o n e : 3 3 6 - 2 7 4 - 9 4 5 6 sc h n a b e l - e n g . c o m LA K E L U R E D A M R E S E R V O I R D R A I N TO W N O F L A K E L U R E RU T H E R F O R D C O U N T Y , N C CH A R L E S M . J O H N S O N , P . E . NO R T H C A R O L I N A P R O F E S S I O N A L E N G I N E E R N O . 0 3 6 1 8 3 DA T E : PROJECT: DATE: FOR BID FEBRUARY 2023 NOT ISSUED FOR CONSTRUCTION DE S C R I P T I O N NLPN 036183 E N EGIN E R ASE L A R O HTOR L O C AR ISESFONA I C H A RLES M . J O H NSONCONCRETE PORTAL PLAN - TOP2 13 00 2'4' SCALE: 3/8"=1'0" RESERVOIR DRAIN SECTION4 13 00 1'2' SCALE: 3/4"=1'0" 5'-11" DIA 8'-0" DIA 6'-6" C ARCH, PORTAL, AND DRAIN 5'-11" DIA PRECAST CONCRETE PORTAL UPSTREAM HOLE ARCH LIFT LINE 10'-6" 2'-012" PRECAST CONCRETE PORTAL STEEL BULKHEAD, SEE SHEET 15 AND 16 EXISTING ARCH PR E C A S T C O N C R E T E PO R T A L A N D MI S C E L L A N E O U S D E T A I L S SK VS CM J 13 OF 16 BULKHEAD FILL VALVE 11'-0" L C PORTAL AND DRAIN L R5" HYDROPHILIC WS ALL AROUND PIPE HEADED STUDS EMBED BEARING PLATE, SEE DETAIL 1 ON SHEET 16 2'-312" CONCRETE CRADLE DETAIL5 13 00 2'4' SCALE: 3/8"=1'0" 5'-1114"± 2'-111 4"± 2'-0" VARIES EXCAVATE TO COMPETENT ROCK, DO NOT UNDERMINE EXISTING STRUCTURE #5@8" EW, TYP #5@8" EW, TYP #9@10' (GALV) 1/2" X 3" STAINLESS STEEL STRAP WITH 1/2" X 3" NEOPRENE PAD ADHERED TO STRAP NTS LIFT LINE DETAIL6 13 DOWNSTREAM FACE OF ARCH TOP SURFACE OF ENCASEMENT ARCH LIFT LINE ABOVE DRAIN PENETRATION WATERPROOFING TAPE 5-IN MIN EPOXY BOND WIDTH 2-IN MIN FREE LENGTH (UNBONDED) PREPARE SURFACE BEFORE TAPE INSTALLATION, SEE MANUFACTURER SPEC TAPE SHALL BE PROTECTED FROM DAMAGE THROUGHOUT CONSTRUCTION 1/2 " Ø X 4 1/2" STAINLESS POST-INSTALLED ADHESIVE ANCHOR BOLTS 10'-0" 3"3" 3" CLR 4'-0" 2'-6"2'-6" 1'-0" 5" 1'-11 4" 5" #5@16" 5'-0" 5" MIN EPOXY BOND WIDTH CONCRETE PORTAL PLAN - BOTTOM3 13 00 2'4' SCALE: 3/8"=1'0" 2'-0" 1'-0" 10'-6" 11'-0" 1'-3" 8'-0" DIA PRECAST CONCRETE PORTAL INNER INSET PRECAST CONCRETE PORTAL R4'-0" ARCH AT CONCRETE PORTAL PLAN1 13 00 2'4' SCALE: 3/8"=1'0" DRILL HOLE THROUGH ARCH, TYP ARCH LIFT LINE 2'-9" 1'-9" SAW CUT BETWEEN DRILL HOLES, BUSH HAMMER SURFACE OF SAW CUT CONCRETE FACE 10'-6" 11'-0" 2'-0" C PORTAL PENETRATION, 18-IN DIA PILOT HOLE, AND DRAIN L 6'-6" 6'-6"2'-0" 6'-6" PRECAST CONCRETE PORTAL ABOVE PRECAST CONCRETE PORTAL R2'-1112" 1#51#5 3" CLR, TYP C ARCH, PORTAL, 18-IN DIA HOLE, AND DRAIN C ARCH, PORTAL, AND DRAIN L C PORTAL AND DRAIN L 3" CLR, TYP L #5@8" EW #5@8" EW 3" CLR 4'-0" 4'-0" #5@8" STIRRUPS EW (OPTIONAL LAP SPLICE AT LONG LEGS) #5@8" VARIES (1'-3" MIN) VARIES (1'-3" MIN) 1" NONSHRINK GROUT ALL AROUND WITH 1-IN THICK BEAD OF SPLASH ZONE EPOXY OR APPROVED EQUIVALENT CONTINUOUS AROUND INSIDE AND OUTSIDE PERIMETERS R23'-114" 1#5, TYP (4 TOTAL) BENT PL 3/8x6x12x0'-8" LONG (SS) WITH (2) 3/4-IN DIA SS HILTI KWIK BOLT TZ2 ANCHOR BOLTS WITH 6-IN MIN EFFECTIVE EMBEDMENT AT MID-LENGTH OF PL (2 PL PER BOTTOM EDGE AT 6-FT OC AND 1 PL AT MID-LENGTH OF TOP AND 2 SIDES) 7" 2" R9" 2'-0" MIN 8" TYP FROM EA CORNER 1" DIA SS THREADED ROD THROUGH 1-1/8" DIA FORMED HOLE IN CONCRETE PORTAL AT EA CORNER (4 TOTAL), DRILL AND EPOXY 24-IN MIN INTO EXIST CONCRETE ARCH 8" TYP FROM EA CORNER 2'-0" MIN 18C21024.020 SHEET DE S I G N E D B Y : DR A W N B Y : CH E C K E D B Y : DA T E RE V . \\ G R E E - F S \ P R O J E C T S \ 2 0 1 8 \ G R E E N S B O R O \ 1 8 C 2 1 0 2 4 _ 0 0 _ L A K E _ L U R E _ D A M \ 0 3 - S E P R O D U C T S \ 0 8 - C A D \ D R A W I N G S \ 0 5 - F I N A L _ D E S I G N \ U N D E R D R A I N D E S I G N \ E N C A S E M E N T D E T A I L S . D W G © Schnabel Engineering 2023 All Rights Reserved LI C E N S E N U M B E R : C - 2 5 9 9 11 A O A K B R A N C H D R I V E / G R E E N S B O R O , N C / 2 7 4 0 7 Ph o n e : 3 3 6 - 2 7 4 - 9 4 5 6 sc h n a b e l - e n g . c o m LA K E L U R E D A M R E S E R V O I R D R A I N TO W N O F L A K E L U R E RU T H E R F O R D C O U N T Y , N C CH A R L E S M . J O H N S O N , P . E . NO R T H C A R O L I N A P R O F E S S I O N A L E N G I N E E R N O . 0 3 6 1 8 3 DA T E : PROJECT: DATE: FOR BID FEBRUARY 2023 NOT ISSUED FOR CONSTRUCTION DE S C R I P T I O N NLPN 036183 E N EGIN E R ASE L A R O HTOR L O C AR ISESFONA I C H A RLES M . J O H NSON RESERVOIR DRAIN BEND PROFILE1 14 00 2'4' SCALE: 1/2"=1'0" RESERVOIR DRAIN BEND SECTION3 14 00 2'4' SCALE: 1/2"=1'0" RE S E R V O I R D R A I N A N D MI S C E L L A N E O U S D E T A I L S SK NA M CM J 14 OF 16 FLOW FLOW 45°108.93" 14.22" 14.22" 28.44" 28.44" 47.39" 47.39" 23.70" 23.70" 18.96" 37.92" 37.92'' 18.96" 108.52" 22.5° 21.27" 28.37" 35.46" 10.64" 14.18" 17.73" 10.64" 14.18" 17.73" 181.55" 180.87" WP WP 45° 45°CJP, TYP UNO 45°CJP, TYP UNO 45° 40' RESERVOIR DRAIN INTERMEDIATE JOINT2 14 00 2'4' SCALE: 1/2"=1'0" FLOW 72-IN OD STEEL PIPE WITH 1/2-IN THICKNESS SEE DETAIL 1 ON SHEET 11 FOR JET FLOW VALVE DRAIN PIPE VERTICAL CLEANOUT4 14 NTS REMOVABLE THREADED PLUG FLUSH WITH CONCRETE TOP SURFACEENCASEMENT TOP SURFACE 6-IN DIA PVC DRAIN PIPE NO 10 304 STAINLESS STEEL MESH SCREEN SEE SPEC 31 27 10 6-IN DIA PVC CLEANOUT PIPE 45 DEG PVC BEND 6-IN DIA 45 DEG PVC WYE 12" CJP, TYP CJP, TYP 00 2'4' SCALE: 1/2"=1'0" 2 PLACES 45° 10'-0" 6" SCH 40 SEAMLESS STEEL PIPE RESERVOIR DRAIN BYPASS SECTION5 14 CJP, TYP AWWA CLASS D FLANGE CONNECTION 18C21024.020 SHEET DE S I G N E D B Y : DR A W N B Y : CH E C K E D B Y : DA T E RE V . \\ G R E E - F S \ P R O J E C T S \ 2 0 1 8 \ G R E E N S B O R O \ 1 8 C 2 1 0 2 4 _ 0 0 _ L A K E _ L U R E _ D A M \ 0 3 - S E P R O D U C T S \ 0 8 - C A D \ D R A W I N G S \ 0 5 - F I N A L _ D E S I G N \ U N D E R D R A I N D E S I G N \ U P S T R E A M B U L K H E A D . D W G © Schnabel Engineering 2023 All Rights Reserved LI C E N S E N U M B E R : C - 2 5 9 9 11 A O A K B R A N C H D R I V E / G R E E N S B O R O , N C / 2 7 4 0 7 Ph o n e : 3 3 6 - 2 7 4 - 9 4 5 6 sc h n a b e l - e n g . c o m LA K E L U R E D A M R E S E R V O I R D R A I N TO W N O F L A K E L U R E RU T H E R F O R D C O U N T Y , N C CH A R L E S M . J O H N S O N , P . E . NO R T H C A R O L I N A P R O F E S S I O N A L E N G I N E E R N O . 0 3 6 1 8 3 DA T E : PROJECT: DATE: FOR BID FEBRUARY 2023 NOT ISSUED FOR CONSTRUCTION DE S C R I P T I O N NLPN 036183 E N EGIN E R ASE L A R O HTOR L O C AR ISESFONA I C H A RLES M . J O H NSON DRAIN BULKHEAD PLAN VIEW1 15 00 2'4' SCALE: 1/2"=1'0" DRAIN BULKHEAD SECTION2 15 00 2'4' SCALE: 1/2"=1'0" BU L K H E A D D E T A I L S 1 SK NS CM J 15 OF 16 2 15 8' - 6 " Ø x 1 " C O V E R P L A T E 1' - 4 " 1' - 7 " 1' - 4 " 1' - 4 " W1 0 x 3 3 R E I N F O R C I N G R I B S 9' - 2 5 16 " 3'-11" 1' - 7 " 1' - 4 " 9" FITTED STIFFENER PL12x8 CENTERED AT LIFTING LUG 2'-1" EMBED PL12x10 x 0'-10" w/ 12"Øx6" HEADED STUDS (Ga=7) 15 8" CL R PL1x6x0'-6" w/ 114"Ø FOR PIN AND BUSHING 1"Ø SS PIN McMASTER -CARR PRODUCT 90378A261 OR EQUIVALENT SS COTTER PIN McMASTER-CARR PRODUCT 92391A175 OR EQUIVALENT HINGE PLAN VIEW HINGE DETAIL3 15 00 1'2' SCALE: 1"=1'0" W10 WELD PLs TO W10 JACK SCREW ROD w\ THR'D END 2" 1"Ø SS PIN McMASTER -CARR PRODUCT 90378A261 OR EQUIVALENT SS COTTER PIN McMASTER-CARR PRODUCT 92391A175 OR EQUIVALENTPLAN VIEW SIDE VIEW LIFTING LUG DETAILS4 15 00 1'2' SCALE: 1"=1'0" T/ PRECAST CONC PORTAL 15 8" CLR 2" PL1x4x0'-4" w/ 1116"Ø FOR HINGE PIN JACK ROD CONN PL W10 FLG CL OF LIFTING LUG IS CL OF BULKHEAD AND MIDWAY BETWEEN THE HINGES 1 3 4" 3 1 2"7" CONN PL1x312 x 0'-7" w/ 5 8"Ø NUT WELDED ON END TO MATCH SCREW ROD THREADING LIFTING JACK CONNECTION DETAILS5 15 00 1'2' SCALE: 1"=1'0" BOTTOM VIEW SIDE VIEW BOLT PATTERN FOR SCREW JACK 412" 612" 41 4" 214" 21 4"21 4" 1116"Ø HLS CAP PL12x6 x 0'-8" HSS 3x3 (BELOW) 63 4" 6" 2" HSS3x3x14 x 1'-03 4" STL CAP PLATE FOR JACK SCREW 114 "Ø HOLE FOR PIVOT PIN AND BUSHING TRASH RACK FRAMING (BY OTHERS) 9" 1'-5" 812"812" 412" 41 2" 1116"Ø HLS FOR GALV 5 8"Ø ASTM A325 BOLTS. TRASH RACK SHOULD HAVE LONG SLOTTED HLS PERP TO ROTATION TO PROVIDE FOR FITUP TOLERANCE 1"Ø -0.004 -0.002 x 112" SMOOTH SS ROD w/ BRASS BUSHING (McMASTER-CARR PRODUCT 6338K438 OR EQUIVALENT), EACH SIDE OF HSS3x3 L4x4x14 FRAME LIFTING JACK CONNECTION DETAIL. SEE DETAIL 5 ON SHEET 15 911 16 " 12 12 2" 2" R = 4 " HINGE BAR FRONT VIEW 1" THK HINGE BAR CUT FROM PLATE 4" 2" PL12x4 CROSS BAR BETWEEN HINGE BARS 3" 12" 1 16 7'-53 4" 1' - 1 " 2" (12) 5 8"Ø BOLTS THRU 1"Ø HLS IN COVER PLATE. BOLTS SHALL BE EVENLY SPACED (30°) AROUND PERIMETER OF BULKHEAD. GENERAL STEEL NOTES: 1.CONTRACTOR SHALL COORDINATE LAYOUT AND ASSEMBLY PROCESS WITH TRASH RACK SUPPLIER / DESIGNER AND PRECAST CONCRETE SUPPLIER. 2.FILLET WELDS SHALL BE AT LEAST 14" BUT NOT LESS THAN PRESCRIBED BY AISC 360-10 TABLE J2.4 OR AS OTHERWISE CALLED OUT ON PLAN. 3.ALL WELDING SHALL BE CONTINUOUS SEAL WELDING. 4.ALL WELDING SHALL BE PERFORMED BY AWS CERTIFIED WELDERS CERTIFIED IN THE WELDING PROCEDURE TO BE PERFORMED. 5.WELDING SHALL BE MADE USING E70xx ELECTRODES. 6.STAINLESS STEEL TO CARBON STEEL WELDING SHALL USE 309 FILLER AND A LOW-HEAT PROCEDURE. BRASH BUSING FOR 1"Ø PIN. McMASTER -CARR PRODUCT 6338K438 OR EQUIVALENT BRASS BUSHING FOR 1"Ø PIN. McMASTER -CARR PRODUCT 6338K438 OR EQUIVALENT 23 4"Ø HOLE FITTED END STIFFENER PL 1/2 PL1/2x5" RIM BAND HINGE BAR 114"Ø HOLE MATCH DRILLED THROUGH ALL PLATES AT HINGES HINGE BARS, SEE DETAIL 3 ON SHEET 15 SEAL PLATE AND O-RING (BELOW), SEE DETAIL 1 ON SHEET 16 LIFTING LUG. SEE DETAIL 4 ON SHEET 15 PRECAST CONCRETE PORTAL, SEE SHEET 13 TRASH RACK SHALL BE DESIGNED TO SUPPORT A 6.0 KIP AXIAL LOAD THRU AN ANGLE OF 0° TO 35° FROM VERTICAL AS SHOWN. AXIAL LOAD SHALL BE APPLIED AT THE PIVOT POINT AS DEFINED ABOVE. APPROXIMATE TRASH RACK OUTLINE DESIGNED BY TRASH RACK SUPPLIER. REFER TO DETAIL 2 ON SHEET 16 AND SPECIFICATIONS FOR ADDITIONAL PERFORMANCE REQUIREMENTS 2 STIFFENER PLATES AT 3RD POINTS ON UN-RIBBED ENDS OF COVER PLATE, TYP 2" NPT BRASS FILL BALL VALVE BULKHEAD HINGE, SEE DETAIL 3 ON SHEET 15 PIVOT POINT OF BULKHEAD LIFTING JACK SCREW. HORIZONTAL POSITION LOCATES JACK SCREW ROD IN VERTICAL POSITION WHEN HATCH IS 100° OPEN. VERTICAL DIMENSION IS MINIMUM AND MAY BE ADJUSTED UPWARD AT THE DISCRETION OF THE TRASH RACK DESIGNER. LIFTING LUG. SEE DETAIL 4 ON SHEET 15 DRAIN BULKHEAD OPEN POSITION BULKHEAD BEAM, TYP PL12x4 CROSS BAR BETWEEN HINGE BARS CL HINGE BARS 4" 4" 1'-0" 4"4" 1'-8" 5" 5" JOYCE-DAYTON 5 TON STAINLESS STEEL SCREW JACK (MODEL SWJ65-I3S) OR APPROVED EQUIVALENT CENTERLINE OF PENETRATION AND PORTAL OPENING TRASH RACK ROOF SHALL BE DESIGNED FOR SUPPORT POINT FOR BULKHEAD, PROVIDE CHAIN OR OTHER LOAD-RATED (6 KIP) MECHANICAL MEANS TO SUPPORT BULKHEAD WHEN OPEN, COORDINATE LIFTING CONNECTION REQUIREMENTS WITH BULKHEAD FABRICATOR 18C21024.020 SHEET DE S I G N E D B Y : DR A W N B Y : CH E C K E D B Y : DA T E RE V . \\ G R E E - F S \ P R O J E C T S \ 2 0 1 8 \ G R E E N S B O R O \ 1 8 C 2 1 0 2 4 _ 0 0 _ L A K E _ L U R E _ D A M \ 0 3 - S E P R O D U C T S \ 0 8 - C A D \ D R A W I N G S \ 0 5 - F I N A L _ D E S I G N \ U N D E R D R A I N D E S I G N \ U P S T R E A M B U L K H E A D . D W G © Schnabel Engineering 2023 All Rights Reserved LI C E N S E N U M B E R : C - 2 5 9 9 11 A O A K B R A N C H D R I V E / G R E E N S B O R O , N C / 2 7 4 0 7 Ph o n e : 3 3 6 - 2 7 4 - 9 4 5 6 sc h n a b e l - e n g . c o m LA K E L U R E D A M R E S E R V O I R D R A I N TO W N O F L A K E L U R E RU T H E R F O R D C O U N T Y , N C CH A R L E S M . J O H N S O N , P . E . NO R T H C A R O L I N A P R O F E S S I O N A L E N G I N E E R N O . 0 3 6 1 8 3 DA T E : PROJECT: DATE:FEBRUARY 2023 DE S C R I P T I O N NLPN 036183 E N EGIN E R ASE L A R O HTOR L O C AR ISESFONA I C H A RLES M . J O H NSON BU L K H E A D D E T A I L S 2 SK NA M CM J 16 OF 16 BULKHEAD COVER PLATE SECTION AT O-RING CONNECTION1 16 00 1' SCALE: 1-1/2"=1'0" 2' BULKHEAD BEAM 4' - 2 " (M A X ) 2'-111 4" 6' - 1 1 4" WORKING POINT IS CL OF HINGE PIN PRECAST CONC PORTAL 24°66° INSIDE RADIUS = 3 32" OUTSIDE RADIUS = 0.02" +0.005 -0.000 0.317" +0.002 -0.002 TO SHARP CORNER FULL SCALE DOVETAIL DETAIL1a 16 9" CL OF EMBED PLATE, O-RING, AND SEAL PLATES INSIDE EDGE OF CONCRETE PORTAL AND 72"Ø (OD) PIPE 1/4 1/4 0" +0 . 0 4 5 -0 . 0 0 BULKHEAD PERIMETER PLATE 16 ' - 0 " 10'-7" 412" 1/4 1/4 TRASH RACK SECTION2 16 00 4'8' SCALE: 1/4"=1'0" 3 16 TRASH RACK FRAME BEARING DETAIL3 16 00 1'2' SCALE: 3/4"=1'0" CONT SS PL 3/8X4", MILL TOP SURFACE AFTER WELDING TO EMBED PLATE CONT PL12x5" w/ 12"Øx6" HEADED STUDS @ 9" OC (MAX) ZAMAC 5 ZINC ALLOY CAST IN PLACE INSERT TO RECEIVE 5 8 - 11 UNC THREADED BOLT CONT SS PL5 8x4" w/ DOVETAIL GROOVE. MILL BOT SURFACE AFTER WELDING TO BULKHEAD COVER PLATE. CUT DOVETAIL AFTER MILLING, SEE DETAIL 1a ON THIS SHEET SS 5 8"Ø -11 UNC x 3" LONG (MIN) BOLT INTERMEDIATE SUPPORTS AS REQD, ON SIDES CROSS BEARING BEAM PROVIDE SUPPORT AND CONTROL PLACEMENT OF TRASH RACK DURING INSTALLATION TRASH RACK SHALL NOT BEAR ON DAM SURFACE BEYOND THE LIMITS NEW ARCH INFILL CONCRETE BAR GRATING INTERMEDIATE SUPPORTS BY TRASH RACK DESIGNER, TYP, INSET AS REQD FOR CLEARANCES SIDE FRAME. CLEAR DISTANCE BETWEEN FRAMES IS 12'-6" PANEL RIBS, IF USED, MAY BE TURNED IN OR OUT 10'-10" INTERMEDIATE FRAMING TO SUPPORT SCREW JACK BOX, TYP BOTTOM PANEL OF TRASH RACK GRATING INCLINED PANELS ON THE BACK MAY SPAN HORIZONTALLY OR VERTICALLY TOP AND REAR PANELS ARE SOLID PLATE w/ SUPPORT AS DETERMINED BY TRASH RACK DESIGNER. STOP BAR AND SUPPORT BY TRASH RACK DESIGNER "SKID" PL PITCHED TO MATCH CONTRACTOR'S FIELD VERIFIED CONTACT AT ARCH, ATTACH TO EACH SUPPORT LEG OF SIDE FRAME. AFTER TRASH RACK IS IN PLACE, CONNECT TO ARCH AT THREE PLACES SIDE FRAME TRASH RACK (BEHIND) BOTTOM PANEL TRASH RACK SIDE FRAME PRECAST CONCRETE PORTAL HORIZONTAL SUPPORTS 6" 4" NOT ISSUED FOR CONSTRUCTION FOR BID 0.315" TO 0.319" 3 8"Ø SHORE A 70 O-RING (0.375" +0.007 -0.007 )